LED
• To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards,
please read all warnings and instructions included with and on the luminaire box and all luminaire labels.
• Before installing, servicing or performing routine maintenance upon this equipment, follow these general precautions.
• Installation and service of luminaires should be performed by a qualified licensed electrician.
• Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards
involved. Regular luminaire maintenance programs are recommended.
• It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and
minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, nonabrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/
lens and clean in above manner, replacing damaged gaskets as necessary.
• DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during
transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
• Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in
connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which
are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc., a parent
company of Peerless Lighting.
WARNING
RISK OF ELECTRIC SHOCK
4Disconnect or turn off power before installation or
servicing.
4Verify that supply voltage is correct by comparing it with
the luminaire label information.
4Make all electrical and grounded connections in
accordance with the National Electrical Code (NEC) and
any applicable local code requirements.
4All wiring connections should be capped with UL approved
recognized wire connectors.
4To prevent luminaire row from over-­current: By adding
the input current of each luminaire section marked on
the luminaire, the total current per power feed must not
exceed the maximum line wire amperage marked on the
luminaire and the power feed cord/wire amperage rating
whichever the least.
WARNING
RISK OF BURN
4Allow lamp/luminaire to cool before handling. Do not
touch enclosure or light source.
4Do not exceed maximum wattage marked on luminaire
label.
4Follow all manufacturer’s warnings, recommendations and
restrictions for: driver type, burning position, mounting
locations/methods, replacement and recycling.
Part Number: PIN004102 Description: “INSTR, IMPORTANT SAFETY LED” Revision: C Effective Date: 07/2012 ECO3665 page 1 of 2
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
© 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
General Installation Instructions LED A
General Installation Instructions
LED
CAUTION
RISK OF INJURY
CAUTION
RISK OF FIRE
4Wear gloves and safety glasses at all times when removing
luminaire from carton, installing, servicing or performing
maintenance.
4Avoid direct eye exposure to the light source while it is on.
4Keep combustible and other materials that can burn away
from lamp/lens.
4Do not operate in close proximity to persons, combustible
materials or substances affected by heat or drying.
CAUTION
RISK OF PRODUCT DAMAGE
4Never connect components under load.
4Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.
4Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy
sensors, timing devices, or other related control devices. LED luminaires must be powered directly off a switched circuit.
4Unless individual product specifications deem otherwise: Do not restrict luminaire ventilation. Allow for some volume of airspace
around luminaire. Avoid covering LED luminaires with insulation, foam or other material that will prevent convection or conduction
cooling.
4Unless individual product specifications deem otherwise: Do not exceed luminaire’s maximum ambient temperature.
4Only use luminaire in its intended location.
4LED products are polarity sensitive. Ensure proper polarity before installation.
4Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or
servicing of the unit.
4Do not touch individual electrical components as this can cause ESD, shorten lamp life or alter performance.
4Some components inside the luminaire may not be serviceable. In the unlikely event your unit may require service, stop using the
unit immediately and contact a Peerless Lighting representative for assistance.
4Always read the fixtures complete installation instructions prior to installation for any additional luminaire specific warnings.
SAVE THESE INSTALLATION INSTRUCTIONS
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please visit PeerlessLighting.com.
Peerless Lighting, an Acuity Brands Company, assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
Part Number: PIN004102 Description: “INSTR, IMPORTANT SAFETY LED” Revision: C Effective Date: 07/2012 ECO3665 page 2 of 2
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
© 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
General Installation Instructions LED
B
General Installation Instructions WARNING
To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts and other
hazards:
• Service of the equipment must be performed by qualified service personnel.
• Installation and maintenance must be performed by a person familiar with the construction and operation of this product
and any hazards involved. All applicable codes and ordinances must be followed.
• Read this document before installing, servicing or maintaining this equipment or installing a lamp. These instructions do
not cover all installation, service and maintenance situations. If your situation is not covered, or, if you do not
understand these instructions or additional information is required, contact Peerless Lighting or your local Peerless
Lighting distributor.
• Read and follow all warnings and instructions provided by the lamp manufacturer.
WARNING
Before installing, servicing or maintaining this equipment, follow these general precautions. To reduce the risk of
electrocution:
• Make sure the equipment is properly grounded.
• Always de-energize the circuit and/or equipment before connecting to, disconnecting from or servicing the equipment.
To prevent luminaire row from over-current:
• By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must not
exceed the maximum line wire amperage marked on the luminaire and the power feed cord/wire amperage rating
whichever is the least.
To reduce the risk of fire:
• Keep material away that can burn from hot lamp.
• Make sure lamps are correctly installed.
• Use supply conductors with a minimum installation temperature rating as specified on equipment.
To reduce the risk of personal injury from cuts, abrasions or falling parts:
• Wear gloves to prevent cuts or abrasions from sharp edges when removing from carton, handling and maintaining this
equipment.
• Do not use abrasive materials, glass cleaners or other solvents on reflector or lens. These substances may damage
equipment and cause parts to eventually break and fall.
• Do not install a damaged fixture.
CAUTION
Observe lamp manufacturer’s recommendations and restrictions on lamp operation including but not limited to ballast
type, burning position, replacement and cycling. Use only lamps that comply with applicable ANSI standards.
NOTICE: If lamp is marked
it contains mercury. Follow disposal laws. See www.lamprecycle.org
Peerless Lighting, a division of Acuity Brands Lighting, Inc., assumes no responsibility for
claims arising out of improper or careless installation or handling of this product.
SAVE THESE INSTALLATION INSTRUCTIONS
Part Number: PIN004100 Revision: E Effective Date: 07/2012 ECO3665
Staple Suspended — LED and Fluorescent
INSTALLATION INSTRUCTIONS
PIN005900 REV. D 04/14 ECO3722
SPM9L/SPM9/SPM4
These installation instructions are used for installing the following luminaires and kits:
Luminaires
Support Location
Adjustable Mounting Kit
SPM9L
Normal Power Feed
ACG4FKMTY
SPM9
Emergency Power Feed
ACG4EKMTY
SPM4
Non-Power Feed
ACG4SKMT
Luminaire
End Cap Kit
Dust Cover
VDR Kit
SPM9L
SPM9EP or SPM9FEP
SPM9LDU
SPM9LVDR
SPM9
SPM9EP or SPM9FEP
SPM9DU
SPM9VDR
SPM4
SPM9EP or SPM9FEP
SPM9DU
SPM9VDR
WARNING: Please read the “important safety instructions” prior to installation of this product. The mounting instructions can be found inside the mounting
kits or downloaded from PeerlessLighting.com.
A) Identification of SPM9L, SPM9 and SPM4 Luminaires. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1
B) Cable-Mounted Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2
C) OPTIONAL Dust Cover (DU) Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3
D) OPTIONAL Variable Distribution Reflector (VDR) Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3
A) Identification of SPM9L, SPM9 and SPM4 Luminaires
SPM9L & SPM9
NOTE: The Y-cable hanger for
the first section of a continuous
run is locatd in the end cap kit in
the red hardware box.
SPM4
Aircraft
Cable
Y-Cable
Hanger
Cord
Manager
Y-Cable Hanger Details
Round (EP)
End Cap
Squared (FEP)
End Cap
Wire Connectors
DIMENSIONS OF STANDARD SECTION
Nominal Support Spacing is 4’, 8’ and 12’
U12
U8
U4
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
© 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Llimited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
StapleSuspended—LEDandFluorescentinstallationinstructions
1
Staple Suspended – LED and Fluorescent
PIN005900 REV. D 04/14 ECO3722
SPM9L/SPM9/SPM4
B) Cable-Mounted Installation
1
For individual luminaire (with IND option),
raise the luminaire into position. Insert
aircraft cable in to the gripper of the Y-Cable
hanger. Tighten all safety caps and thumb
lock screws on all Y-Cable hangers. Connect
power cord to line wires and install cord
manager to complete the installation.
4
Raise the connecting luminaire into position.
Insert aircraft cable in to the gripper of the
Y-Cable hanger. Plug in the wire connectors.
(Refer to Section D, Step 2 if installing
SPM9L with a distribution of 0/100.)
2
For modular luminaires, insert power cord
and bushing through knockout of the first
luminaire at the male connector end. Plug
in the wire connectors. Hook the Y-Cable
hanger onto joiner and press on tabs on
joiner to secure.
5
Connect the luminaire at the joiner location.
Repeat Steps 4-5 as necessary to hang
all luminaires in the row. For modular
fluorescent luminaires (left). Bolt luminaires
together with (2) ¼-20 screws using
a Philips screwdriver. For modular LED
luminaires (right). Bolt luminaires together
with (2) ¼-20 socket head screws using a
3/16 socket allen wrench.
3
Fold or break the aligner tab on joiner near
power cord, install and secure end-cap. Raise
the luminaire into position. Insert aircraft
cable in to the gripper of the Y-Cable hanger.
Tighten all safety caps and thumb lock
screws on all Y-Cable hangers.
6
Fold or break the aligner tab on joiner, install
end-cap. Level the whole row at each hanger
location as necessary. Tighten all safety
caps and thumb lock screws on all Y-Cable
hangers. Connect power cord to line wires
and install cord manager to complete the
installation.
7
Optional nLight CAT5 connection.
Where applicable, plug in the CAT5 cable
(provided in the mounting kit) to complete
the installation. Image on left shows SPM9
and SPM4 (fluorescent). Image on right
shows SPM9L (LED).
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
© 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
Staple Suspended – LED and Fluorescent
2
Staple Suspended – LED and Fluorescent
PIN00590 REV. D 04/14 ECO3722
SPM9L/SPM9/SPM4
C) OPTIONAL Dust Cover (DU) Installation
1
For SPM9L (LED), simply remove the dust
cover for cleaning during maintenance and
then restore the part by overlaying it atop
the luminaire as shown.
2
For SPM9 AND SPM4 (Fluorescent), simply
remove the dust cover to re-lamp during
maintenance and then replace the dust cover
centering it over the lamp(s) as shown.
D) OPTIONAL Variable Distribution Reflector (VDR) Installation
1
For optional VDR on SPM9L (LED)
with 60/40, 50/50, 40/60 or 20/80
distribution. Secure VDR to luminaire
housing with (6) #8 screws as shown after
maintenance or retrofitting.
2
For optional VDR on SPM9L (LED) with
0/100 distribution. Fold down the tabs on
the ends of the VDR as part of Section B,
Step 4 for standard luminaire installation,
maintenance and retrofitting.
3
For optional VDR on SPM9 and SPM4
(Fluorescent) with one or two lamps. Place
VDR over the lamp assembly as shown after
maintenance or retrofitting.
4
For optional VDR CLI on SPM4
(Fluorescent) with three lamps. Place the
VDR CLI over the center lamp as shown after
maintenance or retrofitting.
.
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
© 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
Staple Suspended – LED and Fluorescent
2
Download