BOLLARDS CB VRB VSB GEM BNB LE B30 SL Low Level Luminaires For Pathways / Courtyards / Entrances Compact Bollards Round Bollards Square Bollards GEM™ Bollards Bounce® Bollards Era Lantern Bollards Traditional Bollards Site Lightforms Low Level Luminaires Low Level Luminaires Table of Contents Relativity 2-3 CB Compact Bollards 4-7 VRB Vandal Resistant Round Bollards 8-15 VSB Vandal Resistant Square Bollards 16-23 GEM™ Bollards 24-29 BNB Bounce Bollards 30-35 LE Era® Lantern Bollards B30 Bollards SL Site Lightforms ® 36-39 40-43 ® Photometrics 44-59 60-68 Lamp and Electrical Guide 69 KimNOW! 5-Day Shipping s Quality On Demand See Ordering Information Pages SITE / AREA PARKING STRUCTURE ROADWAY ARCHITECTURAL FLOOD ACCENT LANDSCAPE MAILING ADDRESS: P.O. BOX 60080 CITY OF INDUSTRY, CA 91716-0080 BUSINESS ADDRESS: 16555 EAST GALE AVENUE CITY OF INDUSTRY, CA 91745 U.S. A. PHONE 626 / 968 - 5666 FAX 626 / 369 - 2695 ENTIRE CONTENTS © COPYRIGHT 2009 KIM LIGHTING, INC. ALL RIGHTS RESERVED REPRODUCTION IN WHOLE OR IN PART WITHOUT PERMISSION IS STRICTLY PROHIBITED. U.S. PATENTS: D443,094, D313,482 D312,890, 4,231,080, D410,553, D473,333 S www.kimlighting.com Printed in U.S.A. 5507009327 Version 2.2 (11/09) This extensive line of Low Level Luminaires has been designed to provide specifiers with a broad spectrum of lighting solutions for pedestrian areas. Each Luminaire provides unique features for brightness control, vandal resistance, and architectural compatibility. In addition, each fixture has an aesthetic relationship to various Kim pole mounted luminaires, following the Kim Theory of Relativity as a matrix for providing the proper scale and visual logic to the overall outdoor lighting scheme. Since Low Level Luminaires can be subject to vandalism in unsecured areas, most of these fixtures have been engineered to provide superior strength through extra thick components, and base-to-grade connections that withstand considerable force. Outstanding performance is provided by reflector and/or lens designs that delivers broad illumination with low brightness. In combination, the performance, design, and ruggedness of these Kim luminaires is unmatched in the lighting industry. Product Line Selection Criteria Configurations Page CB Compact Bollards • • • • Compact size for smaller gardens and pathways. Suitable for commercial or residential applications. Full louvers provide low fixture brightness. No direct light above horizontal. Not recommended for vandal-prone areas. 4-7 VRB Vandal Resistant Round Bollards • Rugged construction is suitable for public areas where vandalism may occur. • Round form complements curvilinear Kim site luminaires, or architectural elements. • Full high-angle louvers provide low fixture brightness with broad light distribution. No direct light above horizontal. • Vertical wall-wash feature on VRB2 and VRB4. • Concrete shaft models available with complementary unlighted barrier model. 8-15 Alternate Flat Top available on lighted models. Vandal Resistant Square Bollards • Rugged construction is suitable for public areas where vandalism may occur. • Square form complements rectilinear Kim site luminaires, or architectural elements. • Full high-angle louvers provide low fixture brightness with broad light distribution. No direct light above horizontal. • Vertical wall-wash feature on VSB2. • Concrete shaft models available with complementary unlighted barrier model. 16-23 GEM Performance Bollard • Rugged construction for public areas with security. • Round form complements curvilinear Kim site luminaires, or architectural elements. • Gem-like optical configuration provides broad light distribution with attractive lens presence. • Grade-level Pathway Marker also available. • Specify compact fluorescent, HID, or LED sources. 24-29 BNB Bounce® Bollard • Rugged construction is suitable for public areas where vandalism may occur. • Transitional design allows for installation in traditional or contemporary settings. • Matches Kim Lighting’s Bounce and Mini-Bounce pedestrian and wall mounted luminaires. • Specify compact fluorescent, pulse start metal halide, or LED sources. • Three unique shaft designs. 30-35 LE Era® Lantern Bollard • Rugged construction is suitable for public areas where vandalism may occur. • Traditional design matches Kim Lighting’s Era Lantern series of high performance site, pedestrian, and wall mounted luminaires. • Specify compact fluorescent, pulse start metal halide, or LED sources. • Three unique shaft designs. • Full-cutoff optics are dark-sky approved. 36-39 B30 Traditional Bollard • Traditional bollard for secure areas. Not recommended for vandal-prone areas. • Reflector/Louver optical system provides broad light distribution,and higher brightness than louvered bollards. Higher illumination is provided for objects taller than the bollard. 40-43 SL Site Lightforms • Rugged construction for public areas. SL5 and SL6 utilize polycarbonate lenses for vandal-prone areas. • Strong architectural forms complement a wide variety of architectural styles. • Full cutoff optics in SL1 - SL4. Very low brightness. • Specify compact fluorescent, HID, or LED sources. 44-59 VSB ™ KIM LIGHTING 1 Kim Theory of Relativity The Relationship of Outdoor Lighting to Site and Architecture KIM THEORY OF RELATIVITY The purpose of this guideline is to bring a cohesive look to outdoor lighting, maximizing lighting efficiency while preserving the architectural experience. Simply stated, the Kim Theory of Relativity says “Poles belong in parking lots. And, once you leave the parking lot, the outdoor lighting should become less and less conspicuous until it becomes an integral part of the architecture.” In addition, the luminaire style and geometry should remain consistent. If this guideline is utilized, the outdoor lighting will enhance the site and architecture, bringing unity to the outdoor lighting scheme. As Dis tan ce ACA 27" to A rch itec Lum ture ina Dec ire des rea ign ses and , Lu styl min e re ma aire in c Hei ons ght tant and to u nify Sca the le A ACP ligh lso ting 21" Dec sch eme reas es BNS View of Architecture unobstructed by poles 03 03 SITE / ROADWAY ZONE PEDESTRIAN ZONE Parking lots and roadways require luminaires on 20' - 40' poles to efficiently light these large areas. Therefore, this lighting becomes dominant, and sets the design and style for all other lighting as you progress towards the building. As you leave the parking lot and transition to pedestrian areas, poles should decrease in height to 10' - 16'. In addition, luminaires should decrease in scale, and can have more decorative features to be appreciated at the pedestrian level. 2 KIM LIGHTING CB VRB VSB GEM™ BNB LE B30 SL WD SW GEM WF AFL LTV LANDSCAPE / PATH ZONE BUILDING / PERIMETER ZONE Near the building, luminaires should begin to disappear, blending into the landscape and hardscape elements. No pole mounted luminaires should ever be used near the building, as they will dominate the architecture. The only exception would be the use of decorative luminaires to delineate entrances to the structure. Building mounted, architecturally compatible fixtures should be almost invisible. KIM LIGHTING 3 CB Compact Bollards Features 6" Louver Assembly Optics Individual louver components, top, and base are constructed of heavy die-cast aluminum, connected as one unit with four concealed stainless steel screws within the vertical supports. The success of the Compact Bollard’s performance is due to full overlapping louvers which provide total source cutoff above horizontal. A soft glow from the louvers provides sufficient vertical illumination for surrounding plants or pedestrians. For relamping, these screws are removed and the interlocking louvers lifted as one unit, providing access to the glass enclosure and lamp. 24" or 32" overall height Louver base is die-cast aluminum and secures internally to the riser with four concealed stainless steel screws. The glass globe is completely gasketed and utilizes prismatics to optimize and control the light. With recommended coated lamps, a smooth wash of light is achieved with no shadows from the vertical supports. Electrical Components Extruded Aluminum Riser All HPF ballasts and components are factory mounted and prewired to a single bracket for field installation within the riser. 5" diameter .125" thick aluminum extrusion available in two lengths for overall fixture heights of 24" and 32". Vertical groove detail aligns with the vertical fixture supports and serves to strengthen and unify the design. Thick internal ribs at the mounting screw locations provide increased strength. Anchor Base To ensure fixture strength and stability in adverse conditions, the base is heavy cast aluminum and secures the riser with four flush stainless steel sockethead screws finished to match fixture. 2K" MIN INSTALLATION IN SOIL INSTALLATION IN PAVING OR HARDSCAPE INSTALLATION Bollards are installed with anchor bolts imbedded in a poured-in-place concrete footing (by others). Internal anchor base is leveled prior to placing the riser. When installing in soil or landscaping, the concrete footing should be raised at least 2K" to avoid corrosive contact between fixture and soil or standing water. KIM LIGHTING 5 CB Compact Bollards Specifications Top and Louvers: Interlocking die-cast, low-copper (<0.6% Cu) aluminum sections fasten together with concealed stainless steel screws. Louver base assembly fastens internally to riser with 4 concealed screws. Dimensions CB Models 50 to 70 watt Medium Base Lamps 42 watt Compact Fluorescent Riser: Extruded aluminum, 5" diameter, .125" typical wall thickness, external vertical grooves align with vertical members on louver assembly. Attaches to anchor base with 4 countersunk stainless steel flat socket head screws finished to match fixture. CB32 Maximum weight: 20 lb Anchor Base: Heavy sand cast, low-copper (<0.6% Cu) aluminum, fully concealed within riser shaft. Three C" x 10"+ 2" zinc plated anchor bolts, each with two nuts and washers, and a rigid pressboard template. 6" DIA. (152.4 mm) Globe: Internally fluted, clear tempered glass, fully gasketed. 5" DIA. 6" (127.0 mm) (152.4 mm) 1L" DIA. 26" (44.5 mm) CONDUIT OPENING 32" (660.4 mm) LIGHT CENTER HEIGHT (812.8 mm) 2E" (73.0 mm) BOLT CIRCLE DIA. BASE PLAN CB 5" DIA. (127.0 mm) 2K" MIN. (63.5 mm) Socket: Porcelain medium base rated 4KV for HID and incandescent. Fluorescent is13W-GX23-2; 42W-G24q-4 - Universal Socket. Ballast: Factory mounted to rigid harness suspended from fixture head within the Riser. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 13W Fluorescent: 120V 32°F. starting; 277V 0°F. starting. 26W, 32W, 42W Fluorescent: 120V through 277V High power factor with starting temperature of 0°F. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. CB24 Maximum weight: 17 lb 6" DIA. (152.4 mm) 6" (152.4 mm) 18" (457.2 mm) LIGHT CENTER HEIGHT 24" (609.6 mm) 5" DIA. (127.0 mm) 2K" MIN. (63.5 mm) Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Cut Off IDA Rated - Full Shielded 6 KIM LIGHTING 25C Ambient CB Compact Bollards Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish Option CB32 / 50PMH277 / WH / HS 1 2 3 4 1 Fixture: Cat. No. designates CB fixture. Cat. No.: Cat. No.: CB32 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium INC = Incandescent PL = Compact Fluorescent 50PMH120 50PMH208 50PMH240 50PMH277 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 50HPS120 50HPS208 50HPS240 50HPS277 100INC120 13PL120 13PL277 42PL1201 42PL2081 42PL2401 42PL2771 See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 50 PMH 277 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. CB24 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 NOTE: 70W PMH and HPS are not recommended for CB24 due to extreme light levels at fixture base. 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Cat. No.: Dark Bronze Light Gray DB LG Stealth Gray™ Platinum Silver SG PS White WH Custom Colors CC Consult representative for custom colors. HS 180° trimmable houseside shield that inserts inside lamp enclosure .032" thick natural aluminum, trimmable in field. Cat. No.: EM Battery Back-up: Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. NOTE: For CB32 model only. 4 Optional Houseside Cat. No.: Black BL Shield: 5 Optional Emergency 6 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. NOTE: For CB32 model only. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 7 VRB Configurations Vandal Resistant Round Bollards Single Function Luminaire Dual Function Luminaire VRB1 and VRB3 Horizontal louvers provide 360° of down-lighting with total lamp source cutoff above 90° horizontal. Designed for lighting walkways, entrances, courtyards, and landscaped areas where fixtures are viewable from all directions. See page 10. VRB2 and VRB4 Horizontal louvers provide 210° of cutoff downlighting, and vertical louvers provide 150° of non-cutoff accent lighting. Designed for lighting walkways where adjacent building facades, walls or landscaping may be enhanced by a vertical wash of light. Fixtures should be viewable from the walkway only. See page 10. KIM LIGHTING 9 VRB Vandal Resistant Round Bollards VRB1 and VRB3 Single Function Luminaire Features VRB2 and VRB4 Dual Function Luminaire 360° Horizontal Louvers 360° 210° Horizontal Louvers, 150° Vertical Louvers 210° 150° 65° Louver Angle Compact glass lamp enclosure allows deep horizontal louvers with a high angle for greater light throw. Closed vertical spacing eliminates direct viewing of the light source above horizontal, ensuring glarefree, efficient illumination. Total Source Cutoff Above 90° Vertical Wash Option (VRB2 and VRB4) High-Angle Light Throw Excellent light uniformity and fixture spacing is achieved as a result of the high-angle light throw. Peak candlepower is at 67.5°. 150° of unobstructed illumination provides accent light on building facades, walls or landscaping. Vertical louvers provide protection and shielding along this non-cutoff segment of the fixture. Vertical Section Shadowless Lighting Internal flutes in the glass lamp enclosure eliminate shadows by refracting light around structural supports and vertical louvers. Phosphor coated lamps are recommended, and VRB2 and VRB4 models should be located at least 10' from the vertical surface for best results. Internally fluted, tempered and gasketed glass lamp enclosure. Horizontal Section at Light Center 10 KIM LIGHTING VRB Vandal Resistant Round Bollards Features Vandal Resistant Construction Luminaire components are heavy-wall aluminum castings. The top cap is available in either domed or flat-top configuration, and the louver modules are one-piece castings which provide greater strength than individually stacked louvers. Concealed Access Air Cooling Added security against vandalism is provided by concealed access screws. A standard allen wrench loosens screws, allowing access for lamp replacement by twist-lock removal of the top cap. Complete removal of screws is not required. Natural air currents provide flow-through ventilation, cooling the exterior metal surfaces and interior optical compartment, thereby minimizing excessive heat build-up. Installation and Mounting Base Details Aluminum Shaft Installation in Soil Electrical components are factory mounted and prewired to a rigid bracket, bolted to the anchor base. Aluminum shaft twist-locks to the base casting and secures with two recessed allen screws. Concrete Shaft Installation in Paving or Hardscape Aluminum shaft bollards are installed with anchor bolts in a poured-in-place footing (by others). Internal anchor base is leveled prior to installing the shaft. Paving Installation in Soil Electrical components are factory mounted and prewired to a rigid harness, suspended within the shaft. When mounting in soil, anchor bolt fasteners and other hardware must be protected from soil by grouting. Soil Installation in Paving or Hardscape Concrete shaft bollards are installed with anchor bolts embedded in a below grade, poured-inplace footing (by others). Leveling nuts make installation and alignment fast and accurate. All fastening hardware must not contact soil or other corrosive elements. Paving Soil Wiring and footing (by others). Wiring and footing (by others). KIM LIGHTING 11 VRB1 / VRB3 Vandal Resistant Round Bollards VRB1 and VRB3 VRB Models 70 to 100 watt Medium Base Lamps 42 watt Compact Fluorescent VRB1 - Single Function Luminaire (Aluminum Shaft) Maximum weight: 30 lb 8" (203.2 mm) DIA. 6" 8" (203.2 mm) DIA. 9" (152.4 mm) (228.6 mm) 3L" 36" (95.3 mm) CONDUIT OPENING (914.4 mm) LIGHT CENTER HEIGHT 5" (127.0 mm) 42"* BOLT CIRCLE DIA. (1066.8 mm) BASE PLAN VRB ALUMINUM SHAFT *30" OR 36" OVERALL HEIGHT 1K" AVAILABLE - CONTACT KIM REPRESENTATIVE (27K" ABSOLUTE MINIMUM) (38.1 mm) ANCHOR BOLT PROJECTION VRB1C - Single Function Luminaire (Concrete Shaft) Maximum weight: 115 lb 8" (203.2 mm) DIA. 6" (152.4 mm) 42" (1066.8 mm) MAXIMUM HEIGHT ABOVE GRADE 8" (203.2 mm) DIA. 9" (228.6 mm) 3C" (85.7 mm) CONDUIT OPENING 30" (762.0 mm) MINIMUM HEIGHT ABOVE GRADE 16 (406.4 mm) 16" MAXIMUM BURIAL DEPTH Specifications Top Cap: One-piece, low-copper (<0.6% Cu) aluminum F" minimum thickness, secured to louvers by concealed allen screws in keyhole slots. For relamping access, allen screws shall not require complete removal. VRB1: Domed Top VRB3: Flat Top Louvers: Die cast, low-copper (<0.6% Cu) aluminum horizontal louvers with four vertical ribs for concealed mounting hardware. 65° upward pitch and provides fully shielded lamp. Louver casting shall be secured to shaft by four internal tie rods. Lamp Enclosure: One-piece tempered molded glass with internal flutes and full gasketing at bottom edge. Socket: Porcelain medium base socket rated 4KV for HID and incandescent. Plastic socket for Fluorescent. Fixture Head: Allows flow-through ventilation around and above the lamp enclosure. Shaft: One-piece extruded aluminum, .125" wall thickness with a heavy cast aluminum twist-lock anchor base concealed within the shaft. Concealed set screws shall lock shaft onto the cast anchor base. Ballast: VRB1 and VRB3 - Factory mounted to rigid harness attached to the anchor base. Wiring shall be supplied from the socket for field connection to the prewired ballast components. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. VRB1C and VRB3C - Factory mounted to rigid harness for field wiring and suspension from fixture head within the concrete shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks, each with two nuts, washers and a rigid pressed board template. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. VRB1C and VRB3C Concrete Shaft Specifications 9K" (241.3 mm) BOLT CIRCLE DIA. BASE PLAN VRB CONCRETE SHAFT VRBC - Unlighted Concrete Bollard Maximum weight: 150 lb 8" (203.2 mm) DIA. 42" (1066.8 mm) MAXIMUM HEIGHT ABOVE GRADE 9K" (241.3 mm) BOLT CIRCLE DIA. BASE PLAN VRBC Material: Cement shall conform to current specifications for “Portland Cement.” ASTM C150, Type I or II. Aggregates shall meet current requirements of “Specifications for Concrete Aggregates,” ASTM C33. Water shall be clean and free from deleterious amounts of silt, oil, acids, alkalies or organic materials. Wire for reinforcement shall conform to ASTM A185. Steel for lugs and plates shall conform to ASTM A36, or A283 grade D. Surface: Medium sand-blasted with anti-graffiti sealer. Available colors are Charcoal, Brown, Natural Gray or White, integral in concrete mix. Cure and Strength: Allows for completion of the hydration process, and result in a 28 day compressive strength of not less than 4,500 psi. Manufacture: Fiberglass molds used to insure uniform parts. Mold parting lines may be slightly visible in finished parts. Anchorage: Four steel mounting tabs for installation on four K" x 10" + 2" zinc electroplated L-hook anchor bolts. Each anchor bolt is supplied with two nuts, two washers, and a rigid pressed board template. Shipment: Palletized with adequate hold-downs to prevent load movement in transit. VRBC same as VRB1C except: No fixture, electrical elements, or conduit openings. Flat top not available. Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Cut Off IDA Rated - Full Shielded 12 KIM LIGHTING 25C Ambient VRB1 / VRB3 Vandal esistant ound Bollards Ordering Information Ordering Example: Fixture Luminaire Electrical Module Finish Option Fixture VRB1/ 70PMH120/ BL / HS 1 2 3 Electrical Module Top Cap Finish Concrete Shaft Finish Option VRB1C / 70PMH120 / BL / CH-C/ HS 5 1 2 Fixture with Aluminum Shaft 3 4 Concrete Finish Fixture VRBC / CH-C 5 1 4 Unlighted Concrete Bollard Fixture with Concrete Shaft 1 Fixture: Cat. No. designates VRB1 and VRB3 fixture and shaft. Top Caps available: VRB1 - Domed Top VRB3 - Flat Top Cat. No.: 2 Electrical Module: 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 PMH = Pulse Start Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 70 PMH 120 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. VRB1 Domed Top Cat. No.: VRB3 Flat Top 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 Ballast for aluminum shaft 42PL1201 42PL2081 42PL2401 42PL2771 VRB1C Domed Top Cat. No.: VRBC VRB3C Flat Top 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 KimNOW! Available Configurations: KN-VRB1/100PMH/DB*, KN-VRB1/100PMH/WH*, KN-VRB1/42PL/DB**, KN-VRB1/42PL/WH** Ballast for concrete shaft * Multi-tap ballast (120, 208, 240, or 277 volts) ** Variable voltage ballast (120 thru 277 volts) 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. 1 Color: Cat. No.: Black BL Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH NOTE: Black and Dark Bronze colors will produce slightly less louver brightness than Light Gray or White. See below. 4 Concrete Finish: Color: Cat. No.: Brown BR-C 5 Optional Houseside Cat. No.: HS 180° trimmable houseside shield that inserts inside lamp enclosure .032" thick natural aluminum, trimmable in field. Cat. No.: EM Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. Shield: 6 Optional Emergency Battery Back-up: Charcoal CH-C Natural Gray NG-C White WH-C Custom Colors CC Consult representative for custom colors. Available colors are integral in concrete mix. For Compact Fluorescent only. 7 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 1 lamp lumens 42W 32W 26W VRB1 and VRB3 models are provided with matching powder coat paint finishes on fixture and shaft. Standard colors are as follows: Cat. No.: Color: BL DB LG SG PS Black Dark Bronze Light Gray Stealth Gray™ Platinum Silver 750 575 450 WH White KIM LIGHTING 13 VRB2 / VRB4 Vandal Resistant Round Bollards VRB Models 70 to 100 watt Medium Base Lamps 42 watt Compact Fluorescent VRB2 - Dual Function Luminaire (Aluminum Shaft) Maximum weight: 30 lb 8" (203.2 mm) DIA. 6" 8" (203.2 mm) DIA. 9" (152.4 mm) (228.6 mm) 3L" (95.3 mm) CONDUIT OPENING 36" (914.4 mm) LIGHT CENTER HEIGHT 42"* 5" (127.0 mm) (1066.8 mm) BOLT CIRCLE DIA. BASE PLAN VRB ALUMINUM SHAFT *30" OR 36" OVERALL HEIGHT 1K" AVAILABLE - CONTACT KIM REPRESENTATIVE (27K" ABSOLUTE MINIMUM) (38.1 mm) ANCHOR BOLT PROJECTION VRB2C - Dual Function Luminaire (Concrete Shaft) Maximum weight: 115 lb 8" (203.2 mm) DIA. 6" (152.4 mm) 8" (203.2 mm) DIA. 9" (228.6 mm) 3C" 42" (1066.8 mm) MAXIMUM HEIGHT ABOVE GRADE (85.7 mm) CONDUIT OPENING 30" (762.0 mm) MINIMUM HEIGHT ABOVE GRADE 16 (406.44 mm) 16" MAXIMUM BURIAL DEPTH 9K" (241.3 mm) BOLT CIRCLE DIA. BASE PLAN VRB CONCRETE SHAFT VRBC - Unlighted Concrete Bollard Maximum weight: 150 lb 8" 42" (203.2 mm) DIA. (1066.8 mm) MAXIMUM HEIGHT ABOVE GRADE 9K" (241.3 mm) Specifications Top Cap: One-piece, low-copper (<0.6% Cu) aluminum F" minimum thickness, secured to louvers by concealed allen screws in keyhole slots. For relamping access, allen screws shall not require complete removal. VRB2: Domed Top. VRB4: Flat Top. Louvers: One-piece, low-copper (<0.6% Cu) aluminum with horizontal and vertical blades. Horizontal louvers shall provide 210° of downlighting with source cutoff above horizontal. Vertical louvers shall provide 150° of non-cutoff lighting. Horizontal louver blades shall have a 1L" depth with a 65° upward pitch from horizontal. Vertical louver blades shall have a 1L" depth with 30° spacing. Louver casting shall be secured to shaft by four internal tie rods. Lamp Enclosure: One-piece tempered molded glass with internal flutes and full gasketing at bottom edge. Socket: Porcelain medium base socket rated 4KV for HID and incandescent. Plastic socket for Fluorescent. Fixture Head:Allows flow-through ventilation around and above the lamp enclosure. Shaft: One-piece extruded aluminum, .125" wall thickness with a heavy cast aluminum twist-lock anchor base concealed within the shaft. Concealed set screws shall lock shaft onto the cast anchor base. Ballast: VRB2 and VRB4 - Factory mounted to rigid harness attached to the anchor base. Wiring shall be supplied from the socket for field connection to the prewired ballast components. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. VRB2C and VRB4C - Factory mounted to rigid harness for field wiring and suspension from fixture head within the concrete shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks, each with two nuts, washers and a rigid pressed board template. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. VRB2C and VRB4C Concrete Shaft Specifications Material: Cement shall conform to current specifications for “Portland Cement.” ASTM C150, Type I or II. Aggregates shall meet current requirements of “Specifications for Concrete Aggregates,” ASTM C33. Water shall be clean and free from deleterious amounts of silt, oil, acids, alkalies or organic materials. Wire for reinforcement shall conform to ASTM A185. Steel for lugs and plates shall conform to ASTM A36, or A283 grade D. Surface: Medium sand-blasted with anti-graffiti sealer. Available colors are: Charcoal, Brown, Natural Gray or White, integral in concrete mix. Cure and Strength: Allows for completion of the hydration process, and result in a 28 day compressive strength of not less than 4,500 psi. Manufacture: Fiberglass molds used to insure uniform parts. Mold parting lines may be slightly visible in finished parts. Anchorage: Four steel mounting tabs for installation on four K" x 10" + 2" zinc electroplated L-hook anchor bolts. Each anchor bolt is supplied with two nuts, two washers, and a rigid pressed board template. Shipment: Palletized with adequate hold-downs to prevent load movement in transit. VRBC sameas VRB2C: No fixture, electrical elements, or conduit openings. Flat top not available. BOLT CIRCLE DIA. BASE PLAN VRBC Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Cut Off IDA Rated - Full Shielded 14 KIM LIGHTING 25C Ambient VRB2 / VRB4 Vandal esistant ound Bollards Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish Fixture VRB2/100HPS120/ LG 1 2 Electrical Module Top Cap Finish Concrete Shaft Finish VRB2C /100HPS120/ LG /NG-C 3 1 2 3 Fixture VRBC / NG-C 4 1 4 Unlighted Concrete Bollard Fixture with Concrete Shaft Fixture with Aluminum Shaft Concrete Finish 1 Fixture: Cat. No. designates VRB2 and VRB4 fixture and shaft. Top Caps available: VRB2 - Domed Top Cat. No.: VRB4 - Flat Top 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 100 HPS 120 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. VRB2 Domed Top Cat. No.: VRB4 Flat Top 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 42PL1201 42PL2081 42PL2401 42PL2771 VRB2C Domed Top Cat. No.: VRBC VRB4C Flat Top 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 42PL1201 42PL2081 42PL2401 42PL2771 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. 1 Color: Cat. No.: Black BL Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH NOTE: Black and Dark Bronze colors will produce slightly less louver brightness than Light Gray or White. See below. 4 Concrete Finish: Color: Cat. No.: Brown BR-C 5 Optional Emergency Cat. No.: EM Battery Back-up: Charcoal CH-C Natural Gray NG-C White WH-C Custom Colors CC Consult representative for custom colors. Available colors are integral in concrete mix. Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 6 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W VRB2 and VRB4 models are provided with matching powder coat paint finishes on fixture and shaft. Standard colors are as follows: Cat. No.: Color: 1 lamp lumens 750 575 450 BL DB LG SG PS WH Black Dark Bronze Light Gray Stealth Gray™ Platinum Silver White KIM LIGHTING 15 VSB Configurations Vandal Resistant Square Bollards Single Function Luminaire Dual Function Luminaire VSB1 Horizontal louvers provide 360° of down-lighting with total lamp source cutoff above 90° horizontal. Designed for lighting walkways, entrances, courtyards, and landscaped areas where fixtures are viewable from all directions. See page 18. VSB2 Horizontal louvers provide 270° of cutoff down-lighting, and vertical louvers provide 90° of non-cutoff accent lighting. Designed for lighting walkways where adjacent building facades, walls or landscaping may be enhanced by a vertical wash of light. Fixtures should be viewable from the walkway only. See page 18. KIM LIGHTING 17 VSB Vandal Resistant Square Bollards Features VSB1 Single Function Luminaire VSB2 Dual Function Luminaire 360° Horizontal Louvers 360° 270° Horizontal Louvers, 90° Vertical Louvers 270° 90° Superior Illumination and Glare Control A compact glass lamp enclosure allows deep horizontal louvers angled for maximum light throw. Close vertical spacing of the louvers provides a 90° cutoff angle eliminating direct viewing of the light source above horizontal. This ensures glare-free, efficient illumination with a peak candlepower of 67.5°, while still allowing for maximum spacing between luminaires. Vertical Wash Option (VSB2) Total Source Cutoff Above 90° 90° of illumination Vertical Section Shadow Control Internal flutes in the glass lamp enclosure decrease shadowing by diffusing or scattering light around the VSB’s structural supports. Phosphor coated lamps are recommended, and VSB2 models should be located at least 10' from the vertical surface being illuminated by the vertical louver fixture segment. Internally fluted, tempered and gasketed glass lamp enclosure. Horizontal Section at Light Center 18 KIM LIGHTING VSB Vandal Resistant Square Bollards Features Vandal Resistant Construction Luminaire components utilize heavy-wall aluminum castings. The gabled top not only withstands high impact, but the design also discourages its use as a resting place. The design of the VSB louver modules provide greater strength than individually stacked louvers. Each louver module interlocks forming a rugged, highly vandal-resistant fixture head. Concealed Access Heat Control Added security against vandalism is provided by concealed access screws. A standard allen wrench is the only tool needed to loosen hidden screws, allowing for easy access to the lamp enclosure. Complete removal of screws is not necessary. A twist and lock top casting is simply removed to allow access for re-lamping. Excessive heat build-up is minimized by the VSB’s open louver architecture. Natural air currents provide flow-through ventilation, cooling the top metal surfaces and interior optical compartment. Yet, the lamp compartment is totally sealed for weatherproof operation. Installation and Mounting Base Details Aluminum Shaft Installation in Soil Electrical components are factory mounted and prewired to a rigid bracket, bolted to the anchor base. Aluminum shaft locks to the base casting and secures with four hex socket stainless steel screws. Concrete Shaft Installation in Paving or Hardscape Aluminum shaft bollards are installed with anchor bolts in a poured-in-place footing (by others). Internal anchor base is leveled prior to installing the shaft. Paving Installation in Soil Electrical components are factory mounted and prewired to a rigid harness, suspended within the shaft. When mounting in soil, anchor bolt fasteners and other hardware must be protected from soil by grouting. Soil Installation in Paving or Hardscape Concrete shaft bollards are installed with anchor bolts embedded in a below grade, poured-inplace footing (by others). Leveling nuts make installation and alignment fast and accurate. All fastening hardware must not contact soil or other corrosive elements. Paving Soil Wiring and footing (by others). Wiring and footing (by others). KIM LIGHTING 19 VSB1 Vandal Resistant Square Bollards VSB Models 70 to 100 watt Medium Base Lamps 42 watt Compact Fluorescent VSB1 - Single Function Luminaire (Aluminum Shaft) Maximum weight: 35 lb 8" (203.2 mm) DIA. 8" (203.2 mm) 7" 10" (177.8 mm) (254.0 mm) 3C" (85.7 mm) CONDUIT OPENING 36" (914.4 mm) LIGHT CENTER HEIGHT 5" (127.0 mm) 43" BOLT CIRCLE DIA. (1092.2 mm) BASE PLAN VSB ALUMINUM SHAFT *30" OR 36" OVERALL HEIGHT 1K" AVAILABLE - CONTACT KIM REPRESENTATIVE (27K" ABSOLUTE MINIMUM) (38.1 mm) ANCHOR BOLT PROJECTION VSB1C - Single Function Luminaire (Concrete Shaft) Maximum weight: 120 lb 8" (203.2 mm) DIA. 7" (177.8 mm) 8" 10" (203.2 mm) (254.0 mm) 3C" 43" (1092.2 mm) MAXIMUM HEIGHT ABOVE GRADE (85.7 mm) CONDUIT OPENING 30" (762.0 mm) MINIMUM HEIGHT ABOVE GRADE 15" 15" (381.0 mm) MAXIMUM BURIAL DEPTH 9K" (241.3 mm) BASE PLAN VSB CONCRETE SHAFT VSBC - Unlighted Concrete Bollard Maximum weight: 175 lb 8" (203.2 mm) 43" Top Cap: One-piece die-cast, low-copper (<0.6% Cu) aluminum F" minimum thickness, secured to louvers by concealed stainless steel allen screws in keyhole slots. For relamping access, allen screws shall not require complete removal. Louvers: One-piece die-cast, low-copper (<0.6% Cu) aluminum with vertical support ribs at 90° intervals. Horizontal louver blades shall have a 1L" depth, and be angled 25° from the horizontal. Louvers shall provide light source cutoff above horizontal. Louver castings shall be secured to shaft by four internal tie rods. Lamp Enclosure: One-piece tempered molded glass with internal flutes and full silicone gasketing at bottom edge. Socket: Porcelain medium base socket rated 4KV for HID Plastic socket for Fluorescent. Fixture Head: Allows flow-through ventilation around and above the lamp enclosure. Shaft: One-piece extruded aluminum, .156" minimum wall thickness with a heavy cast aluminum anchor base concealed within the shaft. Hex socket stainless steel screws shall lock shaft onto the cast anchor base. Ballast: VSB1- Factory mounted to rigid harness attached to the anchor base. Wiring shall be supplied from the socket for field connection to the prewired ballast components. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. VSB1C - Factory mounted to rigid harness for field wiring and suspension from fixture head within the concrete shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks, each with two nuts, washers and a rigid pressed board template. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. VSB1C Concrete Shaft Specifications BOLT CIRCLE DIA. (1092.2 mm) MAXIMUM HEIGHT ABOVE GRADE Specifications Material: Cement shall conform to current specifications for “Portland Cement.” ASTM C150, Type I or II. Aggregates shall meet current requirements of “Specifications for Concrete Aggregates,” ASTM C33. Water shall be clean and free from deleterious amounts of silt, oil, acids, alkalies or organic materials. Wire for reinforcement shall conform to ASTM A185. Steel for lugs and plates shall conform to ASTM A36, or A283 grade D. Surface: Medium sand-blasted with anti-graffiti sealer. Available colors are Charcoal, Brown, Natural Gray or White, integral in concrete mix. Cure and Strength: Allows for completion of the hydration process, and result in a 28 day compressive strength of not less than 4,500 psi. Manufacture: Fiberglass molds used to insure uniform parts. Mold parting lines may be slightly visible in finished parts. Anchorage: Four steel mounting tabs for installation on four K" x 10" + 2" zinc electroplated L-hook anchor bolts. Each anchor bolt is supplied with two nuts, two washers, and a rigid pressed board template. Shipment: Palletized with adequate hold-downs to prevent load movement in transit. VSBC same as VSB1C except: 9K" (241.3 mm) BOLT CIRCLE DIA. BASE PLAN VSBC No fixture, electrical elements or conduit openings. Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Cut Off IDA Rated - Full Shielded 20 KIM LIGHTING 25C Ambient VSB1 Vandal esistant S uare Bollards Ordering Information Ordering Example: Fixture Luminaire Electrical Module Finish Option Fixture VSB1/ 70PMH120/ BL / HS 1 2 3 Luminaire Electrical Module Finish Concrete Shaft Finish Option Fixture VSB1C/ 70PMH120/ BL / CH-C/ HS 5 1 2 Fixture with Aluminum Shaft 3 4 Concrete Finish VSBC / CH-C 5 1 4 Fixture with Concrete Shaft Unlighted Concrete Bollard VSB1C Cat. No.: VSBC 1 Fixture: Cat. No. designates VSB fixture and shaft. Cat. No.: 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 70 HPS 120 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated irconium conversion coating. Cat. No.: VSB1 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 42PL1201 42PL2081 42PL2401 42PL2771 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 42PL1201 42PL2081 42PL2401 42PL2771 1 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH NOTE: Black and Dark Bronze colors will produce slightly less louver brightness than Light Gray or White. See below. 4 Concrete Finish: Color: Cat. No.: Brown BR-C 5 Optional Houseside Cat. No.: HS 180° trimmable houseside shield that inserts inside lamp enclosure .032" thick natural aluminum, trimmable in field. Cat. No.: EM Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. Shield: 6 Optional Emergency Battery Back-up: Charcoal CH-C Natural Gray NG-C White WH-C Custom Colors CC Consult representative for custom colors. Available colors are integral in concrete mix. For Compact Fluorescent only. 7 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 VSB1 models are provided with matching powder coat paint finishes on fixture and shaft. Standard colors are as follows: Cat. No.: Color: BL DB LG SG PS Black Dark Bronze Light Gray Stealth Gray™ Platinum Silver WH White KIM LIGHTING 21 VSB2 Vandal Resistant Square Bollards VSB Models 70 to 100 watt Medium Base Lamps 42 watt Compact Fluorescent VSB2 - Dual Function Luminaire (Aluminum Shaft) Maximum weight: 35 lb 8" (203.2 mm) DIA. 8" (203.2 mm) 7" 10" (177.8 mm) (254.0 mm) 3C" (85.7 mm) CONDUIT OPENING 36" (914.4 mm) LIGHT CENTER HEIGHT 5" (127.0 mm) 43"* BOLT CIRCLE DIA. (1092.2 mm) BASE PLAN VSB ALUMINUM SHAFT *30" OR 36" OVERALL HEIGHT 1K" AVAILABLE - CONTACT KIM REPRESENTATIVE (27K" ABSOLUTE MINIMUM) (38.1 mm) ANCHOR BOLT PROJECTION VSB2C - Dual Function Luminaire (Concrete Shaft) Maximum weight: 120 lb 8" (203.2 mm) DIA. 7" (177.8 mm) 8" 10" (203.2 mm) (254.0 mm) 3C" 43" (1092.2 mm) MAXIMUM HEIGHT ABOVE GRADE (85.7 mm) CONDUIT OPENING 30" (762.0 mm) MINIMUM HEIGHT ABOVE GRADE 15" (381.0 mm) MAXIMUM BURIAL DEPTH Specifications Top Cap: One-piece die-cast, low-copper (<0.6% Cu) aluminum F" minimum thickness, secured to louvers by concealed stainless steel allen screws in keyhole slots. For relamping access, allen screws shall not require complete removal. Louvers: One-piece die-cast, low-copper (<0.6% Cu) aluminum with horizontal and vertical blades. Horizontal louvers shall provide 270° of down-lighting with source cutoff above horizontal. Vertical louver shall provide 90° of non-cutoff lighting. Horizontal louver blades shall have a 1L" depth, and be angled 25° from the horizontal. Vertical louver blades shall have a 1L" depth with a 45° spacing. Louver castings shall be secured to shaft by four internal tie rods. Lamp Enclosure: One-piece tempered molded glass with internal flutes and full silicone gasketing at bottom edge. Socket: Porcelain medium base socket rated 4KV for HID and incandescent. Plastic socket for Fluorescent. Fixture Head: Allows flow-through ventilation around and above the lamp enclosure. Shaft: One-piece extruded aluminum, .156" minimum wall thickness with a heavy cast aluminum anchor base concealed within the shaft. Hex socket stainless steel screws shall lock shaft onto the cast anchor base. Ballast: VSB2 - Factory mounted to rigid harness attached to the anchor base. Wiring shall be supplied from the socket for field connection to the prewired ballast components. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. VSB2C - Factory mounted to rigid harness for field wiring and suspension from fixture head within the concrete shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks, each with two nuts, washers and a rigid pressed board template. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. VSB2C Concrete Shaft Specifications 9K" (241.3 mm) BOLT CIRCLE DIA. BASE PLAN VSB CONCRETE SHAFT VSBC - Unlighted Concrete Bollard Maximum weight: 175 lb 8" (203.2 mm) 43" (1092.2 mm) MAXIMUM HEIGHT ABOVE GRADE Material: Cement shall conform to current specifications for “Portland Cement.” ASTM C150, Type I or II. Aggregates shall meet current requirements of “Specifications for Concrete Aggregates,” ASTM C33. Water shall be clean and free from deleterious amounts of silt, oil, acids, alkalies or organic materials. Wire for reinforcement shall conform to ASTM A185. Steel for lugs and plates shall conform to ASTM A36, or A283 grade D. Surface: Medium sand-blasted with anti-graffiti sealer. Available colors are Charcoal, Brown, Natural Gray or White, integral in concrete mix. Cure and Strength: Allows for completion of the hydration process, and result in a 28 day compressive strength of not less than 4,500 psi. Manufacture: Fiberglass molds used to insure uniform parts. Mold parting lines may be slightly visible in finished parts. Anchorage: Four steel mounting tabs for installation on four K" x 10" + 2" zinc electroplated L-hook anchor bolts. Each anchor bolt is supplied with two nuts, two washers, and a rigid pressed board template. Shipment: Palletized with adequate hold-downs to prevent load movement in transit. VSBC same as VSB2C except: No fixture, electrical elements or conduit openings. 9K" (241.3 mm) BOLT CIRCLE DIA. BASE PLAN VSBC Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Cut Off IDA Rated - Full Shielded 22 KIM LIGHTING 25C Ambient VSB2 Vandal esistant S uare Bollards Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish Fixture VSB2 / 70PMH27 / LG 1 2 Concrete Shaft Finish Luminaire Finish Electrical Module VSB2C / 70PMH277 /LG / NG-C 3 1 2 3 Fixture VSBC / NG-C 4 1 4 Unlighted Concrete Bollard Fixture with Concrete Shaft Fixture with Aluminum Shaft Concrete Finish 1 Fixture: Cat. No. designates VSB fixture and shaft. Cat. No.: 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 70 HPS 120 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated irconium conversion coating. Cat. No.: VSB2 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 42PL1201 42PL2081 42PL2401 42PL2771 Cat. No.: VSBC VSB2C 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 42PL1201 42PL2081 42PL2401 42PL2771 1 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH NOTE: Black and Dark Bronze colors will produce slightly less louver brightness than Light Gray or White. See below. 4 Concrete Finish: Color: Cat. No.: Brown BR-C 5 Optional Houseside Cat. No.: HS 180° trimmable houseside shield that inserts inside lamp enclosure .032" thick natural aluminum, trimmable in field. Cat. No.: EM Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. Shield: 6 Optional Emergency Battery Back-up: Charcoal CH-C Natural Gray NG-C White WH-C Custom Colors CC Consult representative for custom colors. Available colors are integral in concrete mix. For Compact Fluorescent only. 7 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 VSB2 models are provided with matching powder coat paint finishes on fixture and shaft. Standard colors are as follows: Cat. No.: Color: BL DB LG SG PS Black Dark Bronze Light Gray Stealth Gray™ Platinum Silver WH White KIM LIGHTING 23 GEM™ Performance Bollards Features Clear lamp placed high in the optical system Placement of the lamp high in the optical system places the arc-tube above the horizontal illuminance plane. This reduces refractor brightness while increasing luminaire efficiency in the desired luminous zone at 60° from vertical. Hydro-formed Reflector Hydro-formed reflector redirects light down onto pathways, away from viewers’ eyes. Special design features direct light around the lamp to increase illuminance while eliminating streaks and shadows in the beam pattern. Fluted Glass Refractor Precision molded tempered glass refractor spreads light evenly in the beam pattern and eliminates shadows from the luminaire’s support structure. Stepped Body Baffle The stepped design of the lower body reduces surface brightness and provides an attractive texture. Die-cast construction produces sharp detailing. Split Beam Optics Reflector design redirects light away from the lamp and into the useable beam pattern. This provides high illuminance, without unnecessary brightness. The optical system is sealed top and bottom to eliminate the intrusion of dirt and insects. Shadow-less Lighting Working in tandem with the upper reflector, the refractor spreads illuminance laterally. This produces a smooth and even beam pattern with no shadows from the fixture’s structural elements. GEM™ Performance vs. Louvered Bollards GEM™ Bollard Louvered Bollards (VRB and VSB) The GEM™ is designed to produce high levels of illuminance and an attractive lens presence. The visible lens produces a point of interest and attracts attention. Particularly well suited where bollards are used to identify and highlight entries or important walkways. Louvered bollards produce minimal brightness, wide low-level illumination, and incorporate an optical system protected by heavy cast louvers. The robust louvered bodies are well suited to vandal prone areas, and where fixture brightness is undesirable. (Data is shown for white fixture.) 70W MH 26 3' 13.4 Fc KIM LIGHTING 6' 5.4 Fc 9' 1.7 Fc 12' 0.5 Fc 70W MH 3' 2.4 Fc 6' 4.5 Fc 9' 1.6 Fc 12' 0.61 Fc GEM™ Performance Bollards Features Installation and Mounting Base Details Aluminum Shaft Installation in Soil Electrical components are factory mounted and prewired to a rigid bracket, bolted to the anchor base. Aluminum shaft twist-locks to the base casting and secures with two recessed allen screws. Concrete Shaft Installation in Paving or Hardscape Installation in Soil Installation in Paving or Hardscape Aluminum shaft bollards are installed with anchor bolts in a poured-in-place footing (by others). Internal anchor base is leveled prior to installing the shaft. Electrical components are factory mounted and prewired to a rigid harness, suspended within the shaft. Concrete shaft bollards are installed with anchor bolts embedded in a below grade, poured-inplace footing (by others). Leveling nuts make installation and alignment fast and accurate. All fastening hardware must not contact soil or other corrosive elements. Paving When mounting in soil, anchor bolt fasteners and other hardware must be protected from soil by grouting. Soil Paving Soil Wiring and footing (by others). Wiring and footing (by others). Durable Powder Coat Finish • Standard Super TGIC Colors Aluminum • • Titanated Zirconium Conversion Coating Powder Coat Kim’s state-of-the-art powder coat paint system is engineered to provide the highest quality finish with absolute paint adhesion under weather extremes. The Super TGIC thermoset polyester powder coat finish is applied over a titanated zirconium conversion coating. This finish system exceeds the A.S.T.M. 1000 hour salt spray test, enduring over 2500 hours without failure. BL Black DB Dark Bronze Eight Stage Finish LG Light Gray 1. Power wash and degrease. 5. Clear water rinse bath. SG Stealth Gray™ 2. Detergent tank bath. 6. Dry off oven. PS Platinum Silver 3. Clear water rinse bath. WH White 4. Premium titanated zirconium conversion coating as used in the automobile industry. 7. Powder coating, 2.5 mil nominal thickness. 8. Bake for 20 minutes at 410°F. Construction The GEM™ lighted head is constructed of die-cast aluminum, with a molded glass refractor. Four captive, stainless steel fasteners are concealed from view, yet provide easy access for routine maintenance. The lens is not disturbed during re-lamping. The fixture head is secured to the shaft with heavy-duty stainless steel rods. KIM LIGHTING 27 GEM™ Performance Bollards Specifications GEM1 GEM™ Models 70 to 100 watt HID Medium Base Lamps 32 watt Compact Fluorescent GEM1 Maximum weight: 28 lb 9K" (241.3 mm) DIA. 5" 8" (203.2 mm) DIA. 9K" (127.0 mm) (241.3 mm) 3L" 37K" (95.3 mm) CONDUIT OPENING (952.5 mm) LIGHT CENTER HEIGHT 5" (127.0 mm) 42K"* BOLT CIRCLE DIA. (1079.5 mm) BASE PLAN GEM ALUMINUM SHAFT 8" DIA. (203.2 mm) *30" OR 36" OVERALL HEIGHT 1K" AVAILABLE - CONTACT KIM REPRESENTATIVE (27K" ABSOLUTE MINIMUM) (38.1 mm) ANCHOR BOLT PROJECTION GEM1C Maximum weight: 114 lb 9K" (241.3 mm) DIA. 8" 5" (203.2 mm) DIA. 9K" (127.0 mm) (241.3 mm) 3C" 42K" (85.7 mm) CONDUIT OPENING 30K" (1079.5 mm) MAXIMUM HEIGHT ABOVE GRADE (774.7 mm) MINIMUM HEIGHT ABOVE GRADE 8" (203.2 mm) DIA. 16" (406.4 mm) MAXIMUM BURIAL DEPTH 9K" (241.3 mm) BOLT CIRCLE DIA. BASE PLAN GEM CONCRETE SHAFT Top Cap: Die-cast, low-copper (<0.6% Cu) aluminum secured to rib body by captive stainless steel allen cap screws. For lamp access, allen screws shall not require complete removal. Supports: Die-cast, low-copper (<0.6% Cu) aluminum supports secured in place as a complete cage assembly. The top section provides a cutoff lamp compartment. The supports are secured to the shaft by four stainless steel tie rods. Refractor: Thermally tempered soda lime glass sealed with silicone gaskets top and bottom. Socket: Porcelain medium base socket rated 4KV for HID Plastic socket for Fluorescent. Shaft: One-piece aluminum extrusion, .125" minimum wall thickness with a heavy cast aluminum anchor base concealed within the shaft. Hex socket stainless steel set screws shall lock the shaft onto the cast frangible anchor base. See below for GEM1C concrete shaft specifications. Ballast: GEM1 - Factory mounted to rigid harness attached to the anchor base. Wiring shall be supplied from the socket for field connection to the prewired ballast components. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W and 32W Fluorescent: High power factor with starting temperature of 0°F. GEM1C - Factory mounted to rigid harness for field wiring and suspension from fixture head within the concrete shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W and 32W Fluorescent: High power factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; three (3) modules for 45 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, 45 watt or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. Anchor Bolts: Four C" x 10" + 2" zinc plated J-bolts, each with two nuts, washers and a rigid pressed board template. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. GEM1C Concrete Shaft Specifications: OPTIONAL HOUSESIDE SHIELD 5K" (139.7 mm) 3K" (88.9 mm) Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Semi Cut Off 28 KIM LIGHTING 25C Ambient Material: Cement to conform to current specifications for “Portland Cement.” ASTM C150, Type I or II. Aggregates meet current requirements of “Specifications for Concrete Aggregates,” ASTM C33. Water to be clean and free from deleterious amounts of silt, oil, acids, alkalies or organic materials. Wire for reinforcement to conform to ASTM A185. Steel for lugs and plates to conform to ASTM A36, or A283 grade D. Surface: Medium sand-blasted with anti-graffiti sealer. Available colors are Charcoal, Brown, Natural Gray or White, integral in concrete mix. Cure and Strength: Allows for completion of the hydration process, and results in a 28 day compressive strength of not less than 4,500 psi. Manufacture: Fiberglass molds used to insure uniform parts. Mold parting lines may be slightly visible in finished parts. Anchorage: Four steel mounting tabs for installation on four K" x 10" + 2" zinc electroplated J-bolts. Each anchor bolt is supplied with two nuts, two washers, and a rigid pressed board template. Shipment: Palletized with adequate hold-downs to prevent load movement in transit. GEM™ Performance Bollards Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish Optional Houseside Shield GEM1 / 70PMH277 / PS / HS 1 2 3 5 Fixture Electrical Module Luminaire Finish Concrete Optional Shaft Houseside Finish Shield GEM1C / 70PMH277 / PS / NG-C / HS 1 Fixture with Aluminum Shaft 2 3 4 5 Fixture with Concrete Shaft 1 Fixture: Cat. No. designates GEM ™ fixture and shaft. Cat. No.: 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. 30LED120 30LED277 45LED120 45LED277 60LED120 60LED277 Lamp Lamp Line Watts Type Volts 70 PMH 277 Clear lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Shaft Finish: Cat. No.: GEM1 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 32PL1201 32PL2081 32PL2401 32PL2771 IES Type1 30LED120 30LED277 45LED120 45LED277 60LED120 60LED277 IES Type 3 IES Type5 Battery Back-up: 32PL1201 32PL2081 32PL2401 32PL2771 IES Type1 IES Type 3 IES Type5 32PL operates one 26 or 32 watt lamp at120 thru 277 volts (50-60 Hz). NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Dark Bronze DB Light Gray LG Aluminum Riser (Shaft): Cat. No.: HS Shield: 6 Optional Emergency 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 1 Shaft is finished to match fixture with super TGIC powder coat paint over titanated zirconium conversion coating. 5 Optional Houseside 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 GEM1C Stealth Gray™ SG Cat. No.: CH-C BR-C NG-C WH-C Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Concrete Riser (Shaft): Charcoal Brown Natural Gray White 90° trimmable houseside shield .032" thick aluminum, painted to match fixture. Houseside Shield Cat. No.: EM Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 7 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 29 BNB Bounce Bollard Configurations New LED and Traditional Styling Options Era Lantern Bollards also meet strict IES and IDA full cutoff dark sky standards, and are constructed with Kim Lighting’s legendary reputation for quality and durability to last a lifetime. KimLighting.com offers lighting professionals unlimited access to the entire Era Lantern series, including specifications, photometry data, and design tools. Contact your Kim Lighting representative for additional assistance. Era Lantern Bollard. This is outdoor lighting perfection. This is Kim Lighting.Kim Lighting’s exclusive Bounce Bollard series has been broadened to include several new shaft styles and design details to further complement Kim Lighting’s extensive Bounce® series of area, pedestrian scale, and wall-mounted luminaires. And now, new energy efficient LED modules, up to 60W, are now available for all Bounce Bollard models. Unlike typical lantern products that emit the majority of their light in the horizontal plane, the Kim Lighting Bounce series employs an ingenious patented cutoff optical system for efficient distribution of illumination onto the ground and incorporates a controlled up-light feature for a comfortable, subtle, and unique nighttime presence. Kim Lighting’s Bounce Bollard series is perfect for pedestrian zones, congregation points, pathways, perimeters, or other lower-mount and landscape applications, and is ideal for traditional or contemporary architecture requiring a striking European accent. Visit www.kimlighting.com for complete specification, ordering, and photometry information on the entire Bounce family of luminaires. BNB1 BNB2 BNB3 BNB4 BNB5 BNB6 KIM LIGHTING 31 BNB Features Bounce Bollard Easy Re-lamping Lamp access is easily achieved by hinging open the hood. The hood is retained by a stainless steel hinge, and three stainless steel captive screws concealed from normal view. Hood is fully sealed against moisture and insects by a one-piece silicone gasket, creating a totally sealed optical chamber. Performance Optics For glare control, the Bounce Bollard utilizes a flat lens, horizontal lamp optical system. The cap produces bounce light to illuminate pedestrians or surrounding vertical elements. Due to the low mounting height, coated lamps are recommended for optimum uniformity on the ground. Optional Matte Black Cap For locations where complete cutoff is desired, an optional matte black cap is available. If a very low nighttime fixture presence is desired, it is recommended that a black or dark bronze finish be used for the entire bollard. Quick and Easy Installation A heavy-duty cast aluminum base plate is mounted to four anchor bolts and leveled with leveling nuts. Field wire connections are made to the attached electrical components before the bollard shaft is installed. A pressed board template is provided to secure and position the anchor bolts during the concrete pour. Heavy-Duty Base A heavy cast aluminum base is mechanically fastened to the extruded shaft for superior strength, and elimination of unsightly welds. The base, and entire bollard, fastens to the pre-mounted base plate by four blackened stainless steel bolts. KIM LIGHTING 33 BNB Bounce Bollard Specifications BNB Model 70 to 100 watt PMH 70 to 100 watt HPS Medium Base Lamps 42 watt CFL 30 to 60 watt LED 12" DIA. (304.8 mm) 12" DIA. (304.8 mm) 3C" 3C" (85.7 mm) (85.7 mm) 11" 12B" (279.4 mm) (308.0 mm) 5" DIA. 5F" DIA. (127.0 mm) (131.8 mm) BNB 1/2/3 5" DIA. (127.0 mm) BNB 4/5/6 5" DIA. (127.0 mm) 5" DIA. (127.0 mm) 28" 28" 28" (711.2 mm) (711.2 mm) (711.2 mm) 9C" DIA. (238.1 mm) 9C" DIA. (238.1 mm) Straight - BNB 1/4 Fluted - BNB 2/5 10L" DIA. (273.1 mm) Traditional - BNB 3/6 2G" x 3O" 3L" x 1L" CONDUIT OPENING CONDUIT OPENING 5" BOLT CIRCLE DIA. 8N" DIA. (217.5 mm) 5" BOLT CIRCLE DIA. 10B" DIA. (257.2 mm) Hood and Lens Frame: Die-cast, low copper (<0.6% Cu) aluminum alloy with stainless steel hinge. Hood is opened by loosening one stainless steel captive button-head socket cap screw. F" thick clear flat tempered glass lens seals against the lens frame by a one-piece molded silicone gasket. Lens frame seals against the hood by a one-piece extruded and vulcanized silicone gasket. Reflector Module: Specular Alzak® optical segments are rigidly mounted within an aluminum frame and fastened securely to the hood. A porcelain medium base socket rated 4KV is provided for HID, and a GX24q-4 universal socket is provided for fluorescent. Body Support: BNB1, BNB2, BNB3: Die-cast, low copper alloy (<0.6% Cu) aluminum flanges compress a ribbed extruded aluminum chamber. The four heavy wall extruded aluminum support rods are mechanically fastened to the lens frame with stainless steel fasteners. The support rods are held in position through die-cast arms and mechanically fastened at the bottom with a custom aluminum bolt. The electrical wiring is channeled through a support rod with a brass bushing. BNB4, BNB5, BNB6: Heavy low copper alloy (<0.6% Cu) cast aluminum wiring chamber. The four extruded aluminum support rods are mechanically fastened between the lens frame and wiring chamber with stainless steel bolts. The wiring is channeled through the support rods. Body Cap: Die-cast, low copper (<0.6% Cu) aluminum, retained by two captive stainless steel screws. Optional matte black finish to eliminate bounce light. See page 35. Shaft: BNB1, BNB4: One-piece aluminum extrusion, .125" minimum wall thickness and two internal F" - 16 mounting rods sandwich shaft between base and head. Four internal stainless steel hex-head bolts secure the shaft to the anchor base plate. BNB2, BNB5: One-piece fluted aluminum extrusion, .188" minimum wall thickness and two internal F" - 16 mounting rods sandwich shaft between base and head. Four internal stainless steel hex-head bolts secure the shaft to the anchor base plate. BNB3, BNB6: One-piece cast aluminum.188" minimum wall thickness and two internal F" - 16 mounting rods sandwich shaft between base and head. Anchor Base Plate: A heavy cast aluminum anchor base is provided for mounting to the four C" x 10" + 2" zinc plated J-bolts, each with two nuts and washers. A rigid pressed board template is provided to secure the anchor bolts during concrete pour (5" B.C.D.) Electrical Module: Factory mounted to a rigid harness attached to the Anchor Base. HID: High Power Factor with starting temperatures of -20°F for PMH and -40°F for HPS lamp modes. Fluorescent: High Power Factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; three (3) modules for 45 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, 45 watt or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Full Cut Off IDA Rated - Full Shielded 34 KIM LIGHTING 25C Ambient BNB Bounce Bollard Ordering Information Ordering Example: Fixture Luminaire Finish Electrical Module Options BNB1 / 70PMH120 / BL / HS 1 2 3 4-5 1 Fixture: Cat. No. designates BNB fixture. Cat. No.: BNB1 2 Electrical Module: 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 PMH = Pulse Start Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. BNB2 BNB3 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 BNB4 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 BNB5 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 BNB6 42PL1201 30LED120 42PL2081 30LED277 42PL2401 42PL2771 45LED120 45LED277 IES Type1 60LED120 60LED277 IES Type5 IES Type 3 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 Lamp Lamp Line Watts Type Volts 70 PMH 120 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Houseside Color: Black Cat. No.: BL Dark Bronze DB Cat. No.: HS Optional shield made of stamped louvered aluminum allows streetside light to pass while blocking houseside light. Blackened reflector panels within the reflector also reduces the houseside reflection. Shield: Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Houseside Shield Line Volts: Cat. No.: 5 Optional Fusing: 6 Optional StarView™ Cat. No.: BBC Matte Black Body Cap: 7 Optional Emergency Battery Back-up: Cat. No.: EM 120V SF 208V DF 240V DF 277V SF 347V SF For locations where complete cutoff optical control is desired, an Optional Matte Black Body Cap can be specified. This significantly reduces the indirect up-light distribution, providing complete cutoff. To further reduce the nighttime visual presence of the fixture, specify Black or Dark Bronze luminaire finish. Optional Cap Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 8 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 1 lamp lumens 42W 32W 26W 750 575 450 KIM LIGHTING 35 LE Era® Lantern Bollard Configurations Choose One of Three Shaft Styles Timeless, high performance historical lighting integration throughout the site is now possible with Kim Lighting’s Era Lantern luminaire collection, which now includes an authentically detailed replica bollard series to complete the class. Traditionally, “form before function” was the conventional approach to historic luminaire design, however Era Lantern Bollard optics are unmatched by any other period pathway luminaire. Era Lantern Bollards feature high 95% reflectivity, precise light distributions, advanced Pulse Start Metal Halide, HPS, CFL and LED options, and battery back-up modules for emergency illumination. LE1 LE2 Era Lantern Bollards also meet strict IES and IDA full cutoff dark sky standards, and are constructed with Kim Lighting’s legendary reputation for quality and durability to last a lifetime. KimLighting.com offers lighting professionals unlimited access to the entire Era Lantern series, including specifications, photometry data, and design tools. Contact your Kim Lighting representative for additional assistance. Era Lantern Bollard. This is outdoor lighting perfection. This is Kim Lighting. LE3 KIM LIGHTING 37 LE Era® Lantern Bollard Specifications LE Model 70 to 100 watt PMH 70 to 100 watt HPS Medium Base Lamps 42 watt CFL 30, 45 or 60 watt LED Hood and Lens Frame: Die-cast, low copper (<0.6% Cu) aluminum alloy with stainless steel hinge. Hood is opened by loosening one stainless steel captive button-head socket cap screw. F" thick clear flat tempered glass lens seals against the lens frame by a one-piece molded silicone gasket. Lens frame seals against the hood by a one-piece extruded and vulcanized silicone gasket. Arm: Double curved die-cast, low copper aluminum alloy with internal wiring chamber supports the hood and lens frame. 11K" DIA. (292.1 mm) Hub: Die-cast, low copper aluminum alloy with a die cast access cover. The hub is designed to support the arms. 4N" Reflector Module: Specular Alzak® optical segments are rigidly mounted within an aluminum frame and fastened securely to the hood. A porcelain medium base socket rated 4KV is provided for HID, and a GX24q-4 universal socket is provided for fluorescent. No reflector provided for LED. (115.8 mm) 9D" (244.5 mm) Anchor Base Plate: A heavy cast aluminum anchor base plate is provided for mounting to the four C" x 10" + 2" zinc plated J-bolts, each with two nuts and washers. A rigid pressed board template is provided to secure the anchor bolts during concrete pour. 5" B.C.D. rods sandwich shaft between base and head. 5B" DIA. (130.2 mm) LE 1/2/3 5" DIA. (127.0 mm) 5" DIA. (127.0 mm) 5" DIA. (127.0 mm) 28" 28" 28" (711.2 mm) (711.2 mm) (711.2 mm) 9C" DIA. (238.1 mm) Smooth - LE1 9C" DIA. (238.1 mm) 10L" DIA. Fluted - LE2 Traditional - LE3 (273.1 mm) 2G" x 3O" 3L" x 1L" CONDUIT OPENING CONDUIT OPENING 5" BOLT CIRCLE DIA. 5" BOLT CIRCLE DIA. Electrical Module: Factory mounted to a rigid assembly attached to the anchor base. HID: High Power Factor with starting temperatures of -20°F for PMH and -40°F for HPS lamp modes. Fluorescent: High Power Factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; three (3) modules for 45 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, 45 watt or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. Riser: Smooth – The Riser assembly is a one-piece smooth aluminum extrusion (.188" minimum wall thickness) and a heavy cast aluminum base cover. Two internal C" mounting rods sandwich riser between base and hub. Fluted – The riser assembly is a one-piece fluted aluminum extrusion (.188" minimum wall thickness) and a heavy cast aluminum base cover. Two internal C" mounting rods sandwich riser between base and hub. Traditional – The riser is a heavy cast aluminum base cover. Two internal C" mounting rods sandwich riser between base and hub. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. 1 ULcUL 1598 8N" DIA. (217.5 mm) 1 Suitable for wet locations. 38 KIM LIGHTING CE IESNA Rated - Full Cut Off IDA Rated - Full Shielded 10B" DIA. (257.2 mm) Listings and Ratings IP46 Rated 25C Ambient LE Era Lantern Bollard Ordering Information Ordering Example: Fixture Luminaire Finish Electrical Module Options LE1 / 70PMH120 / BL / HS 1 2 3 4-5 LE2 LE3 1 Fixture: Cat. No. designates BNB fixture. Cat. No.: 2 Electrical Module: LE1 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 PMH = Pulse Start Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 42PL1201 30LED120 42PL2081 30LED277 42PL2401 42PL2771 45LED120 45LED277 IES Type1 60LED120 60LED277 IES Type5 IES Type 3 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Lamp Lamp Line Watts Type Volts 70 PMH 120 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Houseside Color: Black Cat. No.: BL Dark Bronze DB Cat. No.: HS Optional shield made of stamped louvered aluminum allows streetside light to pass while blocking houseside light. Blackened reflector panels within the reflector also reduces the houseside reflection. Shield: Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Houseside Shield Line Volts: Cat. No.: 5 Optional Fusing: 6 Lantern Enclosures: Cat. No.: LS Cat. No.: A 120V SF 208V DF 240V DF 277V SF 347V SF Lexan molded high transmission luminous white enclosure replaces standard glass lens. Acrylic molded high transmission luminous white acrylic enclosure replaces standard glass lens. Optional lantern enclosure 7 Optional Emergency Battery Back-up: Cat. No.: EM Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 8 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 39 B30 Traditional Bollard Features High Performance and Low Glare The exclusive Kim optical Louver system achieves a broad light distribution with low glare. A high degree of visibility is attained, allowing lower wattages and greater fixture spacings for energy conservation and cost reduction. Clean Detailing Kim bollards are clean, simple, unobtrusive forms that look as good up close as they do from a distance. A precision look is attained with careful attention to detail such as flush joints, counter sunk fasteners, and quality components. Quick and Easy installation Easy Re-lamp Bollards utilize a mounting ring containing the ballast and related electrical components. This ring is attached to the anchor bolts, leveled, and field wire connections are made prior to mounting the fixture. Direct access to the lamp is achieved by simply removing the top. Concealed Mounting Simple Maintenance Bollard mounting hardware utilizes a twist-lock base connection with concealed fasteners and set-screws. With the top removed, all major components are readily accessible for cleaning or replacement. Reflectors are mounted as a completely self-contained sub-assembly. KIM LIGHTING 41 B30 Traditional Bollard Specifications B30 B30 Model 70 to 100 watt Pulse Start Metal Halide 70 to 100 watt High Pressure Sodium Medium Base Lamps 42 watt Compact Fluorescent B30 Maximum weight: 30 lb 8" DIA. (203.2 mm) 6" 8" DIA. (203.2 mm) 9" (152.4 mm) (228.6 mm) 36" (914.4 mm) LIGHT CENTER HEIGHT 3L" (95.3 mm) CONDUIT OPENING 42"* (1066.8 mm) 5" (127.0 mm) BOLT CIRCLE DIA. BASE PLAN B30 *30" OR 36" OVERALL HEIGHT 1K" (38.1 mm) ANCHOR BOLT PROJECTION OPTIONAL HOUSESIDE SHIELD AVAILABLE - CONTACT KIM REPRESENTATIVE Top Cap: One-piece heavy gauge spun aluminum retained by two countersunk captive socket head fasteners, braced at outer edges by optical assembly. L" thick insulation provided above lamp. Plastic Enclosure: V825-HID acrylic, optically clear, J" nominal wall, one-piece injection molded retained in an unstressed position by internal support through reflector assembly. Optical Assembly: Precision hydroformed optical louvers with specular Alzak® finish, removable as a one piece self-contained unit. Socket: Porcelain with nickel plated socket shell, rated 600 volts. 4KV pulse rated socket. Fluorescent is 42W-G24q-4 - Universal Socket. Shaft: One-piece extruded aluminum, wall thickness, .125" with heavy cast aluminum twist-lock anchor base concealed within post. Post locks to base with (2) C" stainless steel cone point set screws. Gasketing: Fixture is silicone gasketed for weathertight operation. Wiring: Supplied with high temperature socket leads for field connection to the prewired ballast components. Ballast: Factory mounted to rigid harness attached to the anchor base. Wiring shall be supplied from the socket for field connection to the prewired ballast components. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. Anchor Bolts: Four C" x 10" + 2" zinc electro-plated L-hook anchor bolts, each with two nuts and washers and a rigid pressboard template. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. 160° Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Non Cut Off 42 KIM LIGHTING 25C Ambient B30 Traditional Bollard Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish B30-8R / 70HPS120 / BL 1 2 Options / HS 3 4-5 1 Fixture: Cat. No. designates B30 fixture. Cat. No.: 70PMH120 70PMH208 70PMH240 70PMH277 70PMH347 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Houseside 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 42PL1201 42PL2081 42PL2401 42PL2771 See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 70 HPS 120 B30 42PL operates one 26, 32, or 42 watt lamp at120 thru 277 volts (50-60 Hz). 1 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Cat. No.: HS Shield: Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Eliminates backlight in unwanted areas such as ad acent property, or wherever an asymmetric light distribution is desired. Constructed of sheet aluminum covering a 160° arc. Finished to match the fixture. Shield is fully ad ustable about a 360° rotation. Houseside Shield 5 Optional Cat. No.: LC Polycarbonate Enclosure: Clear Polycarbonate CAUTION: Use only when vandalism is anticipated to be high. Useful life is limited due to yellowing caused by UV from sunlight and HID lamps. Polycarbonate enclosure 6 Optional Emergency Battery Back-up: Cat. No.: EM Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 7 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 3 SL Site Lightforms® Full Cutoff Optics in SL1 - SL4 For projects requiring full cutoff pole-mounted luminaires for light trespass or dark-sky considerations, the SL1 - SL4 maintains this theme at the pedestrian level. Each SL fixture has an optical module engineered to produce an asymmetric light distribution using a horizontal lamp, and flat tempered glass lens. Because of the low mounting height, coated HID lamps are recommended for optimum uniformity of illumination. Heavy-Wall Cast Aluminum Heads Kim SL fixtures are specifically designed and engineered to combine contemporary form with rugged vandal-resistant construction. Low level luminaires are often subject to abuse because of their proximity to pedestrian traffic. To combat this, all fixture heads are heavy-wall one-piece aluminum castings. SL models use concealed mechanical head-to-shaft connections for greater strength and clean detailing. SL1 - SL4 models use flat tempered glass lenses, and SL5 and SL6 models use flat polycarbonate lenses. One-Piece Extruded Aluminum Shafts To achieve a clean sharp-cornered architectural appearance with superior strength, all SL shafts are one-piece heavy-wall aluminum extrusions. Integral mounting tracks are incorporated for mechanical attachment of the head and base, which provides superior strength over welding. Low Profile, High Strength Base The SL mounting base is unique in the lighting industry, combining superior strength with a low-profile design. The shaft-to-base attachment is by concealed bolts threaded into the shaft extrusion. Kim tests show this method to be twice the strength of a welded connection. Anchor bolts are provided with couplings, allowing standard black stainless steel bolts to secure the base and eliminate unsightly protruding anchor bolts. See page 47 for anchor bolt and installation details. 46 KIM LIGHTING Features SL Site Lightforms® Installation Details Anchor Bolts and Template Template screw. Replaced with black stainless steel bolt at fixture installation. All SL models are supplied complete with anchor bolts and rigid template. The unique anchor bolt system employs female threaded couplings that allow the standard black stainless steel bolts to secure the base, eliminating unsightly protruding anchor bolts. Template Female Coupling Jam Nut Anchor Bolt Installation in Planted Areas When SL fixtures are to be installed in planted areas, slightly elevate the base to avoid prolonged submersion during heavy rains or irrigation. Allow ground cover or shrubbery to conceal the base. In this application, the template elevation must allow for any top soil or mulch that will be added. The SL template is the same size as the fixture base, and can be used to shape the concrete footing to blend with the base casting. A carefully leveled template will provide a smooth flat mounting surface and a level fixture. Level template and footing Finished Grade Ground Cover Template Top Soil Conduit System (by others) Anchor Bolt Installation Conduit System (by others) Concrete and Soil Engineering (by others) Finished Installation Installation in Paved Areas SL fixtures are easily installed in paved areas with an option of a standard or concealed base detail. For standard base installations, the concrete footing is poured with the template at finished grade level. While the SL base casting is very low in profile, it can also be totally concealed by paving up to the fixture shaft. Although a concealed base detail is aesthetically very clean, it must be remembered that future removal will be difficult if required. Level template and footing Finished Grade Finished Grade Expansion Joint Expansion Joint Template Paving Conduit System (by others) Anchor Bolt Installation, Standard Base. Conduit System (by others) Concrete and Soil Engineering (by others) Anchor Bolt Installation, Concealed Base. Finished Installation, Standard Base. Finished Installation, Concealed Base. KIM LIGHTING 47 SL1 Site Lightforms® Specifications Head: One-piece cast, low-copper (<0.6% Cu) aluminum, F" wall thickness with external reveal unifying head and shaft. Attachment to shaft is by four bolts concealed within the head. SL1 Model 50 to 70 watt HID Medium Base Lamps 42 watt Compact Fluorescent Shaft: One-piece extruded aluminum with internal tracks for attaching head and base. Base: One-piece cast, low-copper (<0.6% Cu) aluminum secured to shaft by four concealed stainless steel bolts. SL1 Maximum weight: 37 lb 8" 8E" (203.2 mm) (225.4 mm) 3B" (79.4 mm) 4K" Lens: Clear flat B" thick tempered glass retained by two stainless steel brackets, and four stainless steel, hex socket cap screws, fully gasketed. (114.3 mm) 37K" (952.5 mm) LIGHT CENTER HEIGHT 42"* (1066.8 mm) *36" OVERALL HEIGHT AVAILABLE - CONTACT KIM REPRESENTATIVE 8" (203.2 mm) Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. 8K" (215.9 mm) BOLT CIRCLE DIA. BASE PLAN SL1 CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. Listings and Ratings IP46 Rated CE IESNA Rated - Full Cut Off IDA Rated - Full Shielded 48 KIM LIGHTING Ballast: Factory mounted to rigid harness suspended from fixture head within the shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 13W Fluorescent: 120V 32°F. starting; 277V 0°F. starting. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. Anchor Bolts: Four C" x 10"+2" zinc plated L-hooks complete with leveling nuts, washers, couplings, rigid pressed board template and black stainless steel bolts. 9D" (244.5 mm) ULcUL 1598 Reflector and Socket: Formed specular Alzak® reflector panels secured to a harness which holds a porcelain medium base 4KV socket (HID and Incandescent), GX24q-4 - Universal Socket (42W Fluorescent), or two single-ended twin tube sockets (13W Fluorescent). 25C Ambient SL1 Site Lightforms Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish SL1 / 50PMH277 / WH 1 2 3 1 Fixture: Cat. No. designates SL fixture. Cat. No.: 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium SL1 50PMH120 50PMH277 70PMH120 70PMH277 50HPS120 50HPS277 70HPS120 70HPS277 60INC120 13PL1201 13PL2771 42PL1202 42PL2082 42PL2402 42PL2772 30LED120 30LED277 INC = Incandescent PL = Compact Fluorescent 60LED120 60LED277 LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 50 PMH 277 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Emergency Battery Back-up: Two lamps re uired per fixture. 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 2 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Cat. No.: EM Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 5 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 9 SL2 Site Lightforms® Specifications Head: One-piece cast, low-copper (<0.6% Cu) aluminum, F" wall thickness with external reveals to unify head and shaft. Attachment to shaft is by four bolts concealed within the head. SL2 Model 50 to 70 watt HID Medium Base Lamps 42 watt Compact Fluorescent Shaft: One-piece extruded aluminum with internal tracks for attaching head and base. Base: One-piece cast, low-copper (<0.6% Cu) aluminum secured to shaft by four concealed stainless steel bolts. SL2 Maximum weight: 47 lb 8" 21" (203.2 mm) (533.4 mm) Reflector and Socket: (Typical of two) Formed specular Alzak® reflector panels secured to a harness which holds a porcelain medium base 4KV socket (HID and Incandescent), GX24q-4 - Universal Socket (42W Fluorescent), or two single-ended twin tube sockets (13W Fluorescent). 4K" (114.3 mm) Lens: Clear flat B" thick tempered glass retained by two stainless steel brackets, and four stainless steel, hex socket cap screws, fully gasketed. 37K" (952.5 mm) LIGHT CENTER HEIGHT 42"* (1066.8 mm) 3B" (79.4 mm) *36" OVERALL HEIGHT AVAILABLE - CONTACT KIM REPRESENTATIVE 8" (203.2 mm) 9D" Ballast: Factory mounted to rigid harness suspended from fixture head within the shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 13W Fluorescent: 120V 32°F. starting; 277V 0°F. starting. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks complete with leveling nuts, washers, couplings, rigid pressed board template and black stainless steel bolts. (244.5 mm) 8K" (215.9 mm) Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. BOLT CIRCLE DIA. BASE PLAN SL2 CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Full Cut Off IDA Rated - Full Shielded 50 KIM LIGHTING 25C Ambient SL2 Site Lightforms Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish SL2 / 50PMH277 / WH 1 2 3 1 Fixture: Cat. No. designates SL fixture. Cat. No.: 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium SL2 50PMH1201 50PMH2771 70PMH1201 70PMH2771 50HPS1201 50HPS2771 70HPS1201 70HPS2771 60INC1201 13PL1202 13PL2772 42PL1201,3 42PL2081,3 42PL2401,3 42PL2771,3 60LED120 60LED277 INC = Incandescent LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. 120LED120 120LED277 Two lamps re uired per fixture. Four lamps re uired per fixture. 3 42PL operates 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 2 Lamp Lamp Line Watts Type Volts 50 PMH 277 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Emergency Battery Back-up: Color: Black Cat. No.: BL Cat. No.: EM Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 5 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 51 SL3 Site Lightforms® Specifications Head: One-piece cast, low-copper (<0.6% Cu) aluminum, F" wall thickness with external reveal unifying head and shaft. Attachment to shaft is by four bolts concealed within the head. SL3 Model 50 to 70 watt HID Medium Base Lamps 42 watt Compact Fluorescent Shaft: One-piece extruded aluminum with internal tracks for attaching head and base. Base: One-piece cast, low-copper (<0.6% Cu) aluminum secured to shaft by four concealed stainless steel bolts. SL3 Maximum weight: 39 lb 8" 8E" (203.2.mm) (225.4 mm) 3B" (79.4 mm) 5J" (133.4 mm) Lens: Clear flat B" thick tempered glass retained by two stainless steel brackets, and four stainless steel, hex socket cap screws, fully gasketed. 37K" Ballast: Factory mounted to rigid harness suspended from fixture head within the shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 13W Fluorescent: 120V 32°F. starting; 277V 0°F. starting. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. (952.5 mm) LIGHT CENTER HEIGHT 42L"* Reflector and Socket: Formed specular Alzak® reflector panels secured to a harness which holds a porcelain medium base 4KV socket (HID and Incandescent), GX24q-4 - Universal Socket (42W Fluorescent), or two single-ended twin tube sockets (13W Fluorescent). (1085.9 mm) *36L" OVERALL HEIGHT AVAILABLE - CONTACT KIM REPRESENTATIVE 8" (203.2.mm) Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks complete with leveling nuts, washers, couplings, rigid pressed board template and black stainless steel bolts. 9D" (244.5 mm) Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. 8K" (215.9 mm) BOLT CIRCLE DIA. BASE PLAN SL3 CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Full Cut Off IDA Rated - Full Shielded 52 KIM LIGHTING 25C Ambient SL3 Site Lightforms Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish SL3 / 50PMH277 / WH 1 2 3 1 Fixture: Cat. No. designates SL fixture. Cat. No.: 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium SL3 50PMH120 50PMH277 70PMH120 70PMH277 50HPS120 50HPS277 70HPS120 70HPS277 60INC120 13PL1201 13PL2771 42PL1202 42PL2082 42PL2402 42PL2772 30LED120 30LED277 INC = Incandescent PL = Compact Fluorescent 60LED120 60LED277 LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 50 PMH 277 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Emergency Battery Back-up: Two lamps re uired per fixture. 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 2 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Cat. No.: EM Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 5 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 53 SL4 Site Lightforms® Specifications Head: One-piece cast, low-copper (<0.6% Cu) aluminum, F" wall thickness with external reveals to unify head and shaft. Attachment to shaft is by four bolts concealed within the head. SL4 Model 50 to 70 watt HID Medium Base Lamps 42 watt Compact Fluorescent Shaft: One-piece extruded aluminum with internal tracks for attaching head and base. Base: One-piece cast, low-copper (<0.6% Cu) aluminum secured to shaft by four concealed stainless steel bolts. SL4 Maximum weight: 47 lb 8" 21" (203.2 mm) (533.4 mm) Reflector and Socket: (Typical of two) Formed specular Alzak® reflector panels secured to a harness which holds a porcelain medium base 4KV socket (HID and Incandescent), GX24q-4 - Universal Socket (42W Fluorescent), or two single-ended twin tube sockets (13W Fluorescent). 5J" (133.4 mm) Lens: Clear flat B" thick tempered glass retained by two stainless steel brackets, and four stainless steel, hex socket cap screws, fully gasketed. 37K" (952.5 mm) LIGHT CENTER HEIGHT 42L"* (1085.9 mm) 3B" (79.4 mm) *36L" OVERALL HEIGHT AVAILABLE - CONTACT KIM REPRESENTATIVE 8" (203.2 mm) 9D" Ballast: Factory mounted to rigid harness suspended from fixture head within the shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 13W Fluorescent: 120V 32°F. starting; 277V 0°F. starting. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks complete with leveling nuts, washers, couplings, rigid pressed board template and black stainless steel bolts. (244.5 mm) 8K" (215.9 mm) Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. BOLT CIRCLE DIA. BASE PLAN SL4 CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Full Cut Off IDA Rated - Full Shielded 54 KIM LIGHTING 25C Ambient SL4 Site Lightforms Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish SL4 / 50PMH277 / WH 1 2 3 1 Fixture: Cat. No. designates SL fixture. Cat. No.: 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium SL4 50PMH1201 50PMH2771 70PMH1201 70PMH2771 50HPS1201 50HPS2771 70HPS1201 70PHS2771 60INC1201 13PL1202 13PL2772 42PL1201,3 42PL2081,3 42PL2401,3 42PL2771,3 60LED120 60LED277 INC = Incandescent PL = Compact Fluorescent 120LED120 120LED277 LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 50 PMH 277 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Emergency Battery Back-up: Two lamps re uired per fixture. Four lamps re uired per fixture. 3 42PL operates 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 2 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Cat. No.: EM Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 5 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 55 SL5 Site Lightforms® Specifications Head: One-piece cast, low-copper (<0.6% Cu) aluminum, F" wall thickness, attached to shaft by four bolts concealed within the head, fully gasketed. SL5 Model 50 to 70 watt HID Medium Base Lamps 42 watt Compact Fluorescent Shaft: One-piece extruded aluminum with internal tracks for base attachment. Cast aluminum top cap internally secured and fully gasketed. Base: One-piece cast, low-copper (<0.6% Cu) aluminum secured to shaft by four concealed stainless steel bolts. SL5 Maximum weight: 37 lb 8" 4J" 4J" (108.0 mm) (108.0 mm) Reflector and Socket: Formed specular Alzak® reflector panel secured to a harness which holds a porcelain medium base 4KV socket (HID and Incandescent), GX24q-4 - Universal Socket (42W Fluorescent), or GX23-2 socket (13W Fluorescent). (203.2 mm) Lens: Clear flat F" thick polycarbonate retained by three captive pressure-limiting allen head shoulder screws, fully gasketed. 9" (228.6 mm) 33" 42"* (838.2 mm) LIGHT CENTER HEIGHT (1066.8 mm) *36" OVERALL HEIGHT AVAILABLE - CONTACT KIM REPRESENTATIVE 8" (203.2 mm) Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks complete with leveling nuts, washers, couplings, rigid pressed board template and black stainless steel bolts. 9D" (244.5 mm) Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. 8K" (215.9 mm) BOLT CIRCLE DIA. BASE PLAN SL5 CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Semi Cut Off 56 KIM LIGHTING Ballast: Factory mounted to rigid harness suspended from fixture head within the shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 13W Fluorescent: 120V 32°F. starting; 277V 0°F. starting. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. 25C Ambient SL5 Site Lightforms Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish SL5 / 50PMH277 / WH 1 2 3 1 Fixture: Cat. No. designates SL fixture. Cat. No.: 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium SL5 50PMH120 50PMH277 70PMH120 70PMH277 50HPS120 50HPS277 70HPS120 70HPS277 100INC120 13PL120 13PL277 42PL1201 42PL2081 42PL2401 42PL2771 15LED120 15LED277 INC = Incandescent PL = Compact Fluorescent 30LED120 30LED277 LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 50 PMH 277 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Emergency Battery Back-up: 42PL operates 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Cat. No.: EM Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 5 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 57 SL6 Site Lightforms® Specifications SL6 Model 50 to 70 watt HID Medium Base Lamps 42 watt Compact Fluorescent SL6 Maximum weight: 39 lb 3B" (79.4 mm) 8" (203.2 mm) 4L" 4L" (120.7 mm) (120.7 mm) 9" (228.6 mm) 33" 42"* (838.2 mm) LIGHT CENTER HEIGHT (1066.8 mm) *36" OVERALL HEIGHT AVAILABLE - CONTACT KIM REPRESENTATIVE 8" (203.2 mm) Anchor Bolts: Four C" x 10" + 2" zinc plated L-hooks complete with leveling nuts, washers, couplings, rigid pressed board template and black stainless steel bolts. Finish/Color: Finish is Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; A.S.T.M. 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™, Platinum Silver, or White. Custom colors are available. 9D" (244.5 mm) 8K" (215.9 mm) BOLT CIRCLE DIA. BASE PLAN SL6 CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. Listings and Ratings ULcUL 1598 IP46 Rated CE IESNA Rated - Semi Cut Off 58 KIM LIGHTING Head: (Typical of two) One-piece cast, low-copper (<0.6% Cu) aluminum, F" wall thickness attached to shaft by four bolts concealed within each head, fully gasketed. Shaft: One-piece extruded aluminum with internal tracks for base attachment. Cast aluminum top cap internally secured and fully gasketed. Base: One-piece cast, low-copper (<0.6% Cu) aluminum secured to shaft by four concealed stainless steel bolts. Reflector and Socket: Formed specular Alzak® reflector panels secured to a harness which holds a porcelain medium base 4KV socket (HID and Incandescent), GX24q-4 - Universal Socket (42W Fluorescent), or two single ended twin tube sockets (13W Fluorescent). Lens: (Typical of two) Clear flat F" thick polycarbonate retained by three captive pressure-limiting allen head shoulder screws, fully gasketed. Ballast: Factory mounted to rigid harness suspended from fixture head within the shaft. Wire leads supplied to base. HID: High power factor with starting temperatures of -20°F. for PMH and -40°F. for HPS lamp modes. 13W Fluorescent: 120V 32°F. starting; 277V 0°F. starting. 26W, 32W, 42W Fluorescent: High power factor with starting temperature of 0°F. LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K). Emitters are directly attached to the electronic driver. LED Driver: Constant current electronic driver. Rated for 30 watt, or 60 watt. Available in 120 volt or 277 volt input. 0°F. starting temperature. All drivers are Underwriters Laboratories recognized. 120V versions are dimmable. 25C Ambient SL6 Site Lightforms Ordering Information Ordering Example: Fixture Electrical Module Luminaire Finish SL6 / 50PMH277 / WH 1 2 3 1 Fixture: Cat. No. designates SL fixture. Cat. No.: 2 Electrical Module: PMH = Pulse Start Metal Halide HPS = High Pressure Sodium SL6 50PMH120 50PMH277 70PMH120 70PMH277 50HPS120 50HPS277 70HPS120 70HPS277 100INC120 13PL1201 13PL2771 42PL1202 42PL2082 42PL2402 42PL2772 30LED120 30LED277 INC = Incandescent PL = Compact Fluorescent 60LED120 60LED277 LED = Light Emitting Diode See lamp and electrical data on page 69 for ballast types and characteristics. Lamp Lamp Line Watts Type Volts 50 PMH 277 Coated lamps recommended. 3 Luminaire Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. 4 Optional Emergency Battery Back-up: Two lamps re uired per fixture. 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). 1 2 NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. Color: Black Cat. No.: BL Cat. No.: EM Dark Bronze DB Light Gray LG Stealth Gray™ SG Platinum Silver PS White WH Custom Colors CC Consult representative for custom colors. Internal battery pack provides 90 minutes of supplemental light at 23% lamp lumens for 26, 32 or 42 watt compact fluorescent lamps. For Compact Fluorescent only. 5 Optional Cold-Pack Emergency Battery Pack: Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed to maintain operation without interruption within a range of hi/low ambient temperatures, -20°C to +55°C. Internal Cold-Pack emergency battery pack provides up to 90 minutes of supplemental light. See table at right for max. lumens output by lamps. Lamp (4-Pin) 42W 32W 26W 1 lamp lumens 750 575 450 KIM LIGHTING 59 CB Compact Bollards Photometrics Typical Quadrant CB32 Luminaire Wattage A 100W. INC. B 13W. PL C 42W. PL D 50W. PMH E 70W. PMH F 50W. HPS G 70W. HPS Lamp Initial Lumens A21 I.F. Medium Base GX23 Base G24D-3 Base ED-17 Medium Base, Coated ED-17 Medium Base, Coated ED-17 Medium Base, Coated E-17 Medium Base, Coated 1690 900 3200 2688 5400 3800 5985 Initial Horizontal Footcandles for 32" Bollard (28.4" Light Center) A B C D 0.12 0.06 0.19 0.24 E 0.39 F 0.27 G 0.43 0.31 0.16 0.51 0.62 0.98 0.69 1.09 6' 1.31 0.66 1.92 2.63 4.18 2.94 4.63 4' 2' 4' 6' 7.75 3.94 9.79 15.60 24.78 17.44 27.46 A 100W. INC. B 13W. PL C 42W. PL D 50W. PMH E 50W. HPS Lamp Initial Lumens A21 I.F. Medium Base GX23 Base G24D-3 Base ED-17 Medium Base, Coated ED-17 Medium Base, Coated 1690 900 3200 2688 3800 KIM LIGHTING Initial Horizontal Footcandles for 24" Bollard (20.4" Light Center) A B C D 0.04 0.02 0.07 0.09 E 0.10 0.12 0.06 0.17 0.25 0.28 6' 0.49 0.25 0.77 0.98 1.10 4' 5.23 2.66 7.59 10.53 11.77 60 2' Typical Quadrant CB24 Luminaire Wattage 8' 2' 4' 6' 8' 2' Photometrics NOTE: All photometric tests were conducted using white fixtures with coated lamps. Clear High Pressure Sodium lamps may be used if slight louver shadows are acceptable. Lamp A 70W. HPS B 100W. HPS C 70W. PMH D 100W. PMH E 100W. INC. F 42W. PL Initial Lumens E-17 Medium Base, Coated E-17 Medium Base, Coated ED-17 Medium Base, Coated ED-17 Medium Base, Coated A21 I.F. Medium Base G24D-3 Base Vandal Resistant Round Bollards Typical Half VRB1 and VRB3 Single Function Luminaire Wattage VRB 5985 8800 5400 8000 1690 3200 Initial Horizontal Footcandles for 42" Bollard (36" Light Center) 21' 18' 15' 12' Black and Dark Bronze colors will produce less louver brightness and illumination levels than Light Gray or White. 9' TYPICAL TYPICALCANDLEPOWER CANDLEPOWERDISTRIBUTION DISTRIBUTIONCURVE CURVEFOR FOR100 100WATT WATTPMH MH 120° 130° 140° 150° 170° 170° 150° 140° 130° 160° 160° 120° A B C D E 6' F 3' 110° 110° 100° 100° 90° 90° 80° 80° 0' 200 70 70° 400 60° 600 800 50° 40° 2.1 3.2 2.4 3.5 .47 1.13 3' 3.8 6.8 4.5 6.6 1.2 2.13 6' 1.4 2.2 1.6 2.3 .37 .76 9' 70 70° .51 .81 .61 .90 .12 .29 12' 60° .23 .39 .27 .40 .06 .13 15' .12 .20 .13 .20 .04 .07 18' .07 .12 .07 .11 .02 .03 21' 50° 30° 20° 10° 0° 10° 20° 30° 0' 40° Lamp A 70W. HPS B 100W. HPS C 70W. PMH D 100W. PMH E 100W. INC. F 42W. PL Initial Lumens E-17 Medium Base, Coated E-17 Medium Base, Coated ED-17 Medium Base, Coated ED-17 Medium Base, Coated A21 I.F. Medium Base G24D-3 Base 6' 9' Typical Half VRB2 and VRB4 Dual Function Luminaire Wattage 3' 5985 8800 5400 8000 1690 3200 12' 15' 18' 21' Non-Cutoff Side Initial Horizontal Footcandles for 42K" Bollard (37K" Light Center) 21' 18' 15' Non-Cutoff Side (Vertical Louvers) Black and Dark Bronze colors will produce less louver brightness and illumination levels than Light Gray or White. 12' Cutoff Side (Horizontal Louvers) 9' TYPICAL TYPICALCANDLEPOWER CANDLEPOWERDISTRIBUTION DISTRIBUTIONCURVE CURVEFOR FOR100 100WATT WATTPMH MH 120° 130° 140° 150° 170° 170° 150° 140° 130° 160° 160° 120° A B C D E 6' F 3' 110° 110° 100° 100° 90° 90° 0' 80° 70 70° 400 Cutoff Side 60° 60° 6' 1.4 2.2 1.6 2.3 .37 .76 9' .51 .81 .61 .90 .12 .29 12' .23 .39 .27 .40 .06 .13 15' 18' .12 .20 .13 .20 .04 .07 800 40° 3.8 6.8 4.5 6.6 1.2 2.13 Non-Cutoff Side 600 50° 3' 80° 200 70 70° 2.1 3.2 2.4 3.5 .47 1.13 50° 30° 20° 10° 0° 10° 20° 30° 40° Cutoff Side .07 .12 .07 .11 .02 .03 21' 0' 3' 6' 9' 12' 15' 18' 21' KIM LIGHTING 61 VSB Vandal Resistant Square Bollards Lamp A 70W. HPS B 100W. HPS C 70W. PMH D 100W. PMH E 100W. INC. F 42W. PL Photometrics Typical Half VSB1 Single Function Luminaire Wattage NOTE: All photometric tests were conducted using white fixtures with coated lamps. Coated lamps must be used to minimize shadows from the luminaire structural supports. Initial Lumens E-17 Medium Base, Coated E-17 Medium Base, Coated ED-17 Medium Base, Coated ED-17 Medium Base, Coated A21 I.F. Medium Base Gx24q-3 Base 5860 8800 5300 8500 1710 3200 Initial Horizontal Footcandles for 43" Bollard (38" Light Center) 21' 18' 15' 12' Black and Dark Bronze colors will produce less louver brightness and illumination levels than Light Gray or White. 9' TYPICAL TYPICALCANDLEPOWER CANDLEPOWERDISTRIBUTION DISTRIBUTIONCURVE CURVEFOR FOR100 100WATT WATTPMH MH 120° 130° 140° 150° 170° 170° 150° 140° 130° 160° 160° 120° A B C D E 6' F 3' 110° 110° 100° 100° 90° 90° 80° 80° 0' 200 70° 70 400 60° 600 800 50° 40° 5.6 8.4 5.1 8.2 1.6 3.6 3' 5.2 7.8 4.7 7.6 1.5 3.7 6' 1.7 2.5 1.6 2.5 .50 1.3 9' 70 70° .62 .93 .56 .90 .18 .53 12' 60° .27 .41 .25 .40 .08 .27 15' .13 .20 .12 .20 .04 .13 18' .06 .10 .06 .10 .02 .01 21' 50° 30° 20° 10° 0° 10° 20° 30° 0' 40° Lamp A 70W. HPS B 100W. HPS C 70W. PMH D 100W. PMH E 100W. INC. F 42W. PL 6' 9' 12' Typical Half VSB2 Dual Function Luminaire Wattage 3' Initial Lumens E-17 Medium Base, Coated E-17 Medium Base, Coated ED-17 Medium Base, Coated ED-17 Medium Base, Coated A21 I.F. Medium Base G24D-3 Base 5860 8800 5300 8500 1710 3200 15' 18' 21' Non-Cutoff Side Initial Horizontal Footcandles for 43" Bollard (38" Light Center) 21' 18' 15' Non-Cutoff Side (Vertical Louvers) Black and Dark Bronze colors will produce less louver brightness and illumination levels than Light Gray or White. 12' Cutoff Side (Horizontal Louvers) 9' TYPICAL TYPICALCANDLEPOWER CANDLEPOWERDISTRIBUTION DISTRIBUTIONCURVE CURVEFOR FOR100 100WATT WATTPMH MH 120° 130° 140° 150° 170° 170° 150° 140° 130° 160° 160° 120° A B C D E 6' F 3' 110° 110° 100° 100° 90° 90° 0' 80° 70 70° 400 Cutoff Side 60° 5.2 7.8 4.7 7.6 1.5 3.7 6' 1.7 2.5 1.6 2.5 .50 1.3 9' .62 .93 .56 .90 .18 .53 12' .27 .41 .25 .40 .08 .27 15' Non-Cutoff Side 60° 600 18' .13 .20 .12 .20 .04 .13 800 50° 3' 80° 200 70 70° 5.6 8.4 5.1 8.2 1.6 3.6 Cutoff Side 50° 21' .06 .10 .06 .10 .02 .01 40° 62 30° KIM LIGHTING 20° 10° 0° 10° 20° 30° 40° 0' 3' 6' 9' 12' 15' 18' 21' GEM™ HID Photometrics Typical Half GEM1 Luminaire Wattage Lamp A 70W. HPS B 100W. HPS C 70W. PMH D 100W. PMH Initial Lumens E-17 Medium Base, Clear E-17 Medium Base, Clear ED-17 Medium Base, Clear ED-17 Medium Base, Clear 6300 9500 6200 9000 Initial Horizontal Footcandles for 42K" Bollard (37K" Light Center) 21' 18' 15' 12' 9' TYPICALCANDLEPOWER CANDLEPOWERDISTRIBUTION DISTRIBUTIONCURVE CURVEFOR FOR100 100WATT WATTPMH MH TYPICAL 120° 130° 140° 150° 170° 170° 150° 140° 130° 160° 160° 120° A B C 6' D 3' 110° 110° 100° 100° 90° 90° 80° 80° 0' 300 70° 600 60° 900 1200 50° 40° 15.7 23.6 13.4 24.9 3' 6.4 9.6 5.4 10.1 6' 1.9 2.9 1.7 3.1 9' 70° 0.6 0.9 0.5 1.0 12' 60° 0.2 0.4 0.2 0.3 15' 0.1 0.2 0.1 0.2 18' 50° 30° 20° 10° 0° 10° 20° 30° 0' 40° Lamp A 70W. HPS B 100W. HPS C 70W. PMH D 100W. PMH Initial Lumens E-17 Medium Base, Clear E-17 Medium Base, Clear ED-17 Medium Base, Clear ED-17 Medium Base, Clear 3' 6' 9' 12' 15' 18' 21' Typical Half GEM1 Luminaire with Houseside Shield Wattage 21' 6300 9500 6200 9000 Initial Horizontal Footcandles for 42K" Bollard (37K" Light Center) 21' 18' 15' 12' 9' TYPICALCANDLEPOWER CANDLEPOWERDISTRIBUTION DISTRIBUTIONCURVE CURVEFOR FOR100 100WATT WATTPMH MH TYPICAL 120° 130° 140° 150° 170° 170° 150° 140° 130° 160° 160° 120° A B C D 6' 110° 110° 3' 100° 100° 0' 90° 90° 3' 80° 80° 300 70° 900 60° 1200 50° 50° 40° 30° 20° PATH SIDE 6' 2.1 3.1 1.8 3.2 9' 0.7 1.0 0.6 1.0 12' 0.3 0.4 0.2 0.4 15' 0.1 0.2 0.1 0.2 18' 70° 600 60° 6.7 10.2 5.8 10.7 10° 0° 10° 20° 30° HOUSE SIDE 21' 40° 0' 3' 6' 9' 12' 15' 18' 21' KIM LIGHTING 63 GEM™ GEM Performance Bollard Photometrics GEM1 Luminaire GEM1 Luminaire with Houseside Shield Wattage Lamp 32W. PL GX24q-3 Base Initial Lumens Wattage Lamp 2400 32W. PL GX24q-3 Base Initial Lumens 2400 Typical Half Typical Half 21' Initial Horizontal 18' Footcandles for 15' 42K" Bollard 12' (37K" Light Center) 9' 6' 3' 0' 4.3 3' 6' 1.4 9' 0.4 12' 0.2 15' 0.1 18' 21' 21' 18' 15' 12' 9' 6' 3' 0' 21' Initial Horizontal 18' Footcandles for 15' 42K" Bollard 12' (37K" Light Center) 9' 6' 3' 0' 3' 6' 1.4 9' 0.4 12' 0.2 15' 0.1 18' 21' 21' 18' 15' 12' 9' 6' 3' 0' 50 50 50° 150° 120 20° 150 120° 120° 150° 90 90° 90° 50 10050 60° 150 60 100 60° 150 200 0° 30° 30 200 30° TYPICAL CANDLEPOWER DISTRIBUTION CURVE FOR 32 WATT PL 150 50° 120 150° 20° 120° 150° 120° 90° 90 90° 60 60° 60° 120 20° 150 120° 150° 50° 120° 150° 100 100 90° 90 90° 90° 90 90° 50 50 100 100 60 150 60° 60°200 150 200 0° 30° 30 0° 30° 150 150 200 200 30 30° 30° 150° 150 50° 120 120° 20° 150° 120° TYPICAL CANDLEPOWER DISTRIBUTION CURVE FOR 32 WATT PL 60 60° 60° 30° 30 30° GEM1 Luminaire with LED Module Typical Half for 30 Watt LED 21' 18' Initial Horizontal Footcandles for 42K" Bollard (37K" Light Center) 15' 12' 9' Typical Half for 45 Watt LED 21' 18' Initial Horizontal Footcandles for 42K" Bollard (37K" Light Center) 15' 12' 9' 18' 12' 9' 6' 6' 3' 3' 3' 0' 0' 1.0 2.0 1.0 0.5 0.2 .0.1 6' 9' 12' 2.0 5.0 2.0 1.0 0.5 0.2 0.1 3' 6' 9' 12' 15' 15' 18' 18' 21' 21' 18' 15' 12' 9' 21' 21' 18' 15' 12' 9' 6' CANDLEPOWER DISTRIBUTION 90° 90 CURVE FOR 30 WATT LED 90° 90 43 86 60 129 60° 64 0' 150° 150 50° 120° 120 20° TYPICAL 150 50° 120 120° 20° 150° 30° 30 3' 60° 60 0° 30° 30 KIM LIGHTING Initial Horizontal Footcandles for 42K" Bollard (37K" Light Center) 15' 6' 3' Typical Half for 60 Watt LED 21' 0' 2.0 3' 5.0 2.0 1.0 0.5 0.2 0.1 6' 9' 12' 15' 18' 6' 0' 150 150° 50° 120 20° TYPICAL 120° 50° 150° 120 20° 150 120° CANDLEPOWER DISTRIBUTION 90 CURVE FOR 90° 45 WATT LED 90 90° 82 164 60 246 60° 30 30° 3' 60 60° 0° 30 30° 21' 21' 18' 15' 12' 9' 50° 150° 120 20° 150 120° 6' 0' 50° 120 150° 150 120° 20° 90 90° 90 90° 86 172 60 258 60° 30 30° 3' 60 60° 0° 30 30° TYPICAL CANDLEPOWER DISTRIBUTION CURVE FOR 60 WATT LED BNB / LE Bounce® Bollard / Era® Lantern Bollard Photometrics BNB & LE Luminaires BNB & LE Luminaires w/ Houseside Shield Typical Half Typical Half Initial Horizontal Footcandles for 42K" Bollard (39F" Light Center) 21' 18' 15' 12' 9' 21' House Side 18' 120° Initial Horizontal Footcandles for 42K" Bollard (39F" Light Center) 15' 12' 9' 6' 6' 3' 3' A B C D E 21.3 34.2 23.6 35.4 12.0 0' 150° 120° 90° 90° 200 400 60° 600 800 30° 0° 60° 30° A B C D E 17.1 27.4 18.9 28.4 8.14 0' 3' 3' 6' 3.82 6.13 4.23 6.34 2.88 6' 9' 0.80 1.29 0.89 1.34 0.70 9' 3.45 5.53 3.81 5.73 2.92 0.62 0.99 0.68 1.02 0.68 12' 0.21 0.34 0.24 0.35 0.20 12' 0.13 0.21 0.15 0.22 0.17 15' 0.08 0.12 0.09 0.13 0.07 15' 0.03 0.06 0.04 0.06 0.03 18' 0.04 0.06 0.05 0.07 0.05 0.02 0.03 0.02 0.03 0.02 0.02 0.03 0.02 0.03 0.02 21' 21' 18' 15' 12' 9' 6' 18' 21' 21' 18' 15' 12' 9' A B C D E 150° 3' 0' 6' A B C D E 70W PMH, ED-17 Med. Base, Coated, 5300 initial lumens 100W PMH, ED-17 Med. Base, Coated, 8500 initial lumens 70W HPS, ED-17 Med. Base, Coated, 5860 initial lumens 100W HPS, ED-17 Med. Base, Coated, 8800 initial lumens 42W PL-T, GX24q-4 Base, 3200 initial lumens 120° 150° TYPICAL CANDLEPOWER DISTRIBUTION 90° CURVE FOR 100 WATT PMH 90° 320 640 60° 960 1280 30° 0.01 0.01 0.01 0.01 0.01 3' 0' 70W PMH, ED-17 Med. Base, Coated, 5300 initial lumens 100W PMH, ED-17 Med. Base, Coated, 8500 initial lumens 70W HPS, ED-17 Med. Base, Coated, 5860 initial lumens 100W HPS, ED-17 Med. Base, Coated, 8800 initial lumens 42W PL-T, GX24q-4 Base, 3200 initial lumens 150° 150° 120° TYPICAL CANDLEPOWER DISTRIBUTION 90° CURVE FOR 100 WATT PMH 90° 60° 30° 0° Path Side 120° 120° 150° 60° 200 400 60° 600 8009' 30° 0° 30° PATH SIDE HOUSE SIDE 60° 0' BNB & LE Luminaires with LED Module 3' 60° Typical Half for 30 Watt LED 21' 18' Initial Horizontal Footcandles for 42K" Bollard (39F" Light Center) 15' 12' 9' 6' 3' 9' Typical Half for 45 Watt LED 21' 18' Initial Horizontal Footcandles for 42K" Bollard (39F" Light Center) 15' 12' 9' 6' 1.00 2.00 2.00 1.00 00.5 00.2 00.1 0.05 0.02 0.01 18' Initial Horizontal Footcandles for 42K" Bollard (39F" Light Center) 15' 12' 9' 6' 3' 3' 0' Typical Half for 60 Watt LED 21' 0' 0' 15' 15' 5.00 5.00 2.00 1.00 0.50 0.20 0.10 0.05 18' 18' 0.02 18' 21' 21' 18' 15' 12' 9' 21' 21' 18' 15' 12' 9' 0.01 21' 21' 18' 15' 12' 9' 6' 3' 6' 9' 12' 120° 150° 6' CANDLEPOWER DISTRIBUTION 90° CURVE FOR 30 WATT LED 25 50 60° 75 100 30° 0 120° TYPICAL 150° 90° PATH SIDE 3' IES Type1 60° 0° 30° HOUSE SIDE 3' 6' 9' 12' 120° 150° 6' CANDLEPOWER DISTRIBUTION 90° CURVE FOR 45 WATT LED 50 100 150 60° 200 30° 0' 120° TYPICAL 150° 90° PATH SIDE 3' IES Type 3 60° 0° 30° HOUSE SIDE 6' 10.0 5.00 2.00 1.00 0.50 0.20 0.10 0.05 3' 9' 12' 15' 150° 120° 120° 100 200 60° 300 400 30° 3' 0' 0.02 TYPICAL CANDLEPOWER DISTRIBUTION 90° CURVE FOR 60 WATT LED 150° 90° PATH SIDE IES Type5 60° 0° 30° HOUSE SIDE KIM LIGHTING 65 B30 High Performance Bollard Photometrics NOTE: The multiplication factor for correction of footcandles and candlepower with optional clear Polycarbonate Enclosure: 0.92 B30 Luminaire Wattage Lamp A 42W. PL B 70W. HPS C 100W. HPS D 70W. PMH E 100W. PMH Initial Lumens GX24q-3 Base E-23K Mogul Base, Coated E-23K Mogul Base, Coated ED-17 Medium Base, Coated ED-17 Medium Base, Coated 2400 5985 8800 5000 8000 E 0' 4.2 12 17 8.5 14 3' 1.4 4.7 6.5 2.8 4.5 6' .54 1.7 2.3 1.1 1.8 9' .26 .71 .95 .55 .88 12' .14 .38 .50 .29 .47 15' .08 .20 .32 .17 .27 18' - .11 .16 .10 .16 21' A 0' 3' 6' B C D - .07 .10 .06 .10 0' 3' 0' 3' 6' 9' 12' 15' 18' 21' 6' Candela Diagrams 75 75 90° 150 225 300 100 200 300 80° 150 90° 400 70° 10° 20° 30° 40° 50° 32W. Compact Fluorescent 42W. 60° 10° 20° 30° 40° 80° 70° 70° 70W. High Pressure Sodium, Coated 10° 20° 30° 40° 50° 90° 200 10° 20° 30° 40° 300 50° 70W. Metal Halide, Coated 66 KIM LIGHTING 400 300 40 60° 100W. High Pressure Sodium, Coated 100 100 200 90° 80° 60° 50° 100 225 100 200 300 300 400 500 600 700 100 200 300 400 500 600 200 90° 80° 80° 70° 70° 60° 10° 20° 30° 40° 50° 100W. Metal Halide, Coated 60° 300 40 SL 1 NOTE: Coated lamps recommended. Photometrics Typical Half SL1 / SL3 Luminaires Wattage A 50W. HPS B 70W. HPS C 50W. PMH D 70W. PMH E (2) 13W. PL F 42W. PL G 60W. INC. Site Lightforms® 1 Lamp Initial Lumens ED17 Medium Base, Coated ED17 Medium Base, Coated ED17 Medium Base, Coated ED17 Medium Base, Coated GX23 Base GX24q-3 Base T10 I.F. Medium Base 3800 5985 2688 5184 900 each 3200 745 Initial Horizontal Footcandles for 42" Fixture (37K" Light Center) 6' A B C D E F G 3' 0' 19 11 7.5 2.7 1.3 .55 .25 .12 .06 SL1 A (2) 50W. HPS B (2) 70W. HPS C (2) 50W. PMH D (2) 70W. PMH E (4) 13W. PL F (2) 42W. PL G (2) 60W. INC. 15 8.3 4.7 1.8 .93 .41 .18 .08 .04 30 16 9 3.5 1.8 .80 .35 .16 .07 9 5 2.5 .90 .40 .20 10 .05 .02 16 8.8 4.4 1.6 .72 .36 .19 .08 .04 4.5 2.5 1.5 .45 .25 .12 .05 .02 .01 3' 6' 9' 12' 15' 0' SL3 3' 6' 9' 12' 15' 18' Typical Quadrant SL2 / SL4 Luminaires Wattage 40 20 10 4 2 1 .40 .20 .10 1 Lamp Initial Lumens ED17 Medium Base, Coated ED17 Medium Base, Coated ED17 Medium Base, Coated ED17 Medium Base, Coated GX23 Base GX24q-3 Base T10 I.F. Medium Base 3800 each 5985 each 2688 each 5184 each 900 each 3200 each 745 each Initial Horizontal Footcandles for 42L" Fixture (37K" Light Center) A B C D E F G 50 30 17 8 4 2 1 .45 .20 .12 100 40 25 15 7 3.5 2 .80 .35 .20 31 18 10 5.2 2.6 1.6 .78 .26 .15 .08 60 35 20 10 5 3 1.5 .50 .28 .15 25 10 5 3.5 1.5 .75 .38 .18 .08 .05 43.9 17.9 8.8 6.3 2.7 1.3 .68 .32 .15 .08 15 5 3 1.8 .75 .50 .30 .10 .05 .03 0' SL2 SL4 3' 6' 9' 12' 15' 0' 3' 6' 9' 12' 15' 18' KIM LIGHTING 67 SL 1 NOTE: Coated lamps recommended. Site Lightforms® SL5 Luminaire SL6 Luminaire Wattage Initial Lumens Lamp1 A 50W. HPS B 70W. HPS C 50W. PMH D 70W. PMH E 13W. PL F 42W. PL G 100W. INC. ED17 Medium Base, Coated ED17 Medium Base, Coated ED17 Medium Base, Coated ED17 Medium Base, Coated GX23 Base GX24q-3 Base A19 I.F. Medium Base Wattage 3800 5985 3400 5400 900 3200 1750 A 50W. HPS B 70W. HPS C 50W. PMH D 70W. PMH E (2) 13W. PL F 42W. PL G 100W. INC. ED17 Medium Base, Coated 3800 ED17 Medium Base, Coated 5985 ED17 Medium Base, Coated 3400 ED17 Medium Base, Coated 5400 GX23 Base 900 each GX24q-3 Base 3200 A19 I.F. Medium Base 1750 Typical Quadrant Initial Horizontal Footcandles for 42" Fixture (33" Light Center) Initial Horizontal Footcandles for 42" Fixture (33" Light Center) B C D E F 6' G A B C D E F Initial Lumens Lamp1 Typical Half A Photometrics G 3' 0' 0' 12 7 3.8 1.5 .75 .35 20 11 6 3 1.2 .70 11 6.3 3.8 1.8 .88 .34 18 10 6 2.8 1.4 .54 4 2 .75 .35 .15 .07 14.9 7.4 2.8 1.3 .56 .27 6 10 4.4 7 2 7.4 2 2.5 4 2.2 3.5 .75 2.8 1.2 1.5 2 1.1 1.8 .50 1.9 .70 .65 1 .57 .90 .28 1 .38 6' 9' 15' .07 .12 .09 .15 .01 .04 .02 3' 6' 9' 12' 15' Typical Half for 30 Watt LED 18' Initial Horizontal Footcandles for 42" Fixture (33" Light Center) 15' 12' 9' 18' 12' 9' 6' 3' 10.0 5.0 2.0 1.0 0.5 0.2 0.1 3' 6' 9' 12' 0' 6' 9' 12' 15' 18' 18' 150 50° 120° 120 20° 150° 90° 90 60° 60 68 6' 3' 0' 150 150° 50° 120° 120 20° TYPICAL CANDLEPOWER DISTRIBUTION 90° 90 CURVE FOR 30 WATT LED 100 200 60° 60 300 0° 30° 30 30° 30 KIM LIGHTING 220.0 110.0 5.0 22.0 11.0 00.5 00.2 0.1 3' 15' 21' 21' 18' 15' 12' 9' Initial Horizontal Footcandles for 42" Fixture (33" Light Center) 15' 3' 0' Typical Half for 60 Watt LED 21' 6' 21' 21' 18' 15' 12' 9' 150 50° 120° 120 20° 150° 90° 90 60° 60 6' 3' 0' 150 150° 50° 120° 120 20° TYPICAL CANDLEPOWER DISTRIBUTION 90° 90 CURVE FOR 240 480 60 WATT LED 60° 60 720 0° 30° 30 9' 12' 15' 0' 18' SL5 Luminaire with LED Module 21' 6' .30 .42 .25 .40 .14 .59 .15 .15 .20 .12 .19 .08 .29 .07 .07 .10 .06 .09 .04 .15 .03 12' .15 .25 .19 .30 .03 .11 .07 .03 .05 .03 .05 .01 .04 .01 0' 3' 3' 7 3.5 1.8 .70 .38 .18 30 30° 3' 6' 9' 12' 15' 18' ED-17 Coated Medium Base 70 M98 15000 5800 ED-17 Clear Medium Base 70 M98 15000 6000 ED-17 Coated Medium Base 100 M90 15000 8700 ED-17 Clear Medium Base 100 M90 15000 9000 50 S68 24000 3800 ED-17 Coated Medium Base 70 S62 24000 5860 ED-17 Clear Medium Base 70 S62 24000 6300 ED-17 Coated Medium Base 100 S54 24000 8800 ED-17 Clear Medium Base 100 S54 24000 9500 13 – 10000 860 32 – 10000 2400 42 – 10000 3200 LED – 75CRI, 3500K 30LED LED 30 – 50000+ 1200 45LED LED 45 – 50000+ 1800 60LED LED 60 – 50000+ 2400 70PMH 70PMH 100PMH 100PMH HIGH PRESSURE SODIUM 50HPS ED-17 Coated Medium Base 70HPS 70HPS 100HPS 100HPS COMPACT FLUORESCENT Coated 13PL GX23-2 Base 32PL Coated GX24q-3 Base 42PL Coated GX24q-4 Base Max. Amps. 3500 Starting Amps. Initial Lumens 1 15000 Open Circuit Life (Hours) M98 PULSE START METAL HALIDE 50PMH ED-17 Coated Medium Base Operating Amps. ANSI Ballast Type 50 Lamp Voltage Lamp Watts Lamp and Electrical Guide 120 208 240 277 347 120 208 240 277 347 0.63 0.40 0.35 0.33 0.24 0.80 0.46 0.40 0.35 0.28 1.16 0.67 0.57 0.50 0.48 1.90 1.00 0.90 0.80 0.65 0.87 0.51 0.47 0.32 0.21 0.55 0.30 0.25 0.25 0.20 1.16 0.67 0.57 0.50 0.48 1.90 1.00 0.90 0.80 0.65 120 0.80 1.90 0.55 1.90 208 240 277 347 120 208 240 277 347 120 208 240 277 347 0.46 0.40 0.35 0.28 1.15 0.66 0.58 0.50 0.40 1.15 0.66 0.58 0.50 0.40 1.00 0.90 0.80 0.65 2.30 1.40 1.15 1.00 1.00 2.30 1.40 1.15 1.00 1.00 0.30 0.25 0.25 0.20 1.20 0.80 0.65 0.60 0.40 1.20 0.80 0.65 0.60 0.40 1.00 0.90 0.80 0.65 2.30 1.40 1.15 1.00 1.00 2.30 1.40 1.15 1.00 1.00 120 208 240 277 120 208 240 277 347 120 208 240 277 347 120 208 240 277 347 120 208 240 277 347 0.55 0.33 0.30 0.26 0.81 0.47 0.40 0.35 0.30 0.81 0.47 0.40 0.35 0.30 1.15 0.67 0.58 0.50 0.39 1.15 0.67 0.58 0.50 0.39 1.24 0.60 0.52 0.45 1.45 0.85 0.75 0.65 0.55 1.45 0.85 0.75 0.65 0.55 2.20 1.25 1.10 0.85 0.70 2.20 1.25 1.10 0.85 0.70 0.58 0.35 0.31 0.25 0.75 0.45 0.37 0.35 0.30 0.75 0.45 0.37 0.35 0.30 1.30 0.75 0.65 0.60 0.45 1.30 0.75 0.65 0.60 0.45 1.24 0.60 0.52 0.45 1.45 0.85 0.75 0.65 0.55 1.45 0.85 0.75 0.65 0.55 2.20 1.25 1.10 0.85 0.70 2.20 1.25 1.10 0.85 0.70 120 277 120 208 240 277 120 208 240 277 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 0.30 0.13 0.31 0.18 0.15 0.13 0.41 0.24 0.20 0.18 120 277 120 277 120 277 – – – – – – – – – – – – 0.25 0.11 0.38 0.16 0.50 0.22 – – – – – – All initial lumen values shown may vary, from one manufacturer to another. Consult lamp manufacturer’s data for exact lumen and life data. NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others. 1 KIM LIGHTING 69