Wireless Wireless Wireless Wireless Broadband Broadband Broadband Broadband 1200 Amps @ -48VDC Single-Bay, 6000 Amps Multi-Bay Cable Cable Cable Cable 163 Power System Click Here to Read About Ne w Produc t Enhancem ents Front View Rear View • 1200 Amps Per Bay (12) 100 Amp hot swappable switchmode rectifiers can be installed • Single and 3 Phase Configurations • Self-Contained Power, Distribution, and Monitoring Operates as an all-inclusive power solution • Customized Distribution Each bay can be equipped with up to four panels. Nine different panel options can provide up to 72 circuit breakers • Simple Controller Easy to navigate, pushbutton controller has two lines of text to allow plant monitoring and control • Remote Monitoring The plant is accessible via the Internet, LAN, or WAN connection when equipped with an optional Gateway® card and GUI screens • SNMP Compliant • Small Footprint 23.62" by 23.62" (600mm by 600mm) • 6000 Amp Power System Up to five bays can be connected in parallel Product Description The 163 is a self-contained, expandable, power and distribution solution. Each plant is equipped with our 100 Amp digital switchmode rectifier modules, which have one of the highest power density ratings available in the industry. Customized distribution is available by combining up to four of the nine available circuit breaker and fuse panels. Up to 24 alarms can be extended to office monitoring equipment via relay contacts. The controller on the front of the 163 allows the user to easily navigate plant menus to view status information, change setpoints, or monitor alarms. The system passes active status information via a CAN bus, ensuring that real-time information is available. Each system can be connected to a LAN, WAN, or the Internet, allowing staff to view plant status or make adjustments remotely. Up to five 163 bays can be connected in parallel, providing up to 6000 Amps @ -48VDC. An optional battery-monitoring panel (BAP) is available, as is a Shunt Monitoring Module (SHM) for additional shunt monitoring. 163/8-03/a Specifications are subject to change without notice. Please visit our website for the latest revision. 1200 Amps @ -48VDC Single-Bay, 6000 Amps Multi-Bay 163 Power System 163 Power System Specifications Input Voltage Range Frequency Range Current Single Phase 3-Phase 220VAC 176 - 265VAC, single or 3-phase 480VAC 320 - 530VAC, single or 3-phase 47 - 63Hz 80 Amps per phase @ 100% load per rectifier shelf 46 Amps per phase @ 100% load per rectifier shelf 40 Amps per phase @ 100% load per rectifier shelf 23 Amps per phase @ 100% load per rectifier shelf Output Float Voltage Range Regulation Current 50 - 60VDC. Factory Set @ 54.0VDC ± - 0.5% Line, ± 1.0% Load, at 10 - 100% load 100 Amps per rectifier, 1200 Amps per bay Environmental Storage Ambient Operating Ambient Nominal Hardened* Humidity Heat Dissipation -40˚F to +158˚F (-40°C to +70°C), from sea level to 5905' (1153m) 23˚F to 122˚F (-5°C to +50°C), from sea level to 5905' (1153m) -40˚F to +149˚F (-40°C to +65°C), from sea level to 5905' (1153m) < 95% non-condensing (maximum) 31,200 BTU/bay @ 100% load Mechanical Height Width Depth Weight Mounting Cooling 84.0" (2133.6mm) 23.62" (600mm) 23.62" (600mm) Up to 950 lbs. (430.9kg) Exact weight is dependent on the distribution configuration Floor Front-to-rear variable speed fan on rectifier modules Documentation Product Manual System Layout Drawing 4380192PD J438163P *Hardened refers to the worst-case temperature operation and the system is de-rated to 80% Specifications are subject to change without notice. Please visit our website for the latest revision. 163/8-03/a 1200 Amps @ -48VDC Single-Bay, 6000 Amps Multi-Bay 163 Power System Visual Indicators Rectifier Module: Controller: LED Description Fail Standby Go LED Description Power Minor Power Major Rectifier Major Rectifier Minor Battery Monitor Distribution Fuse Distribution Current MMC OK Low Low Voltage Low Voltage Color Amber Red Red Amber Amber Red Amber Green Red Amber Color Red Amber Green LED Description High Voltage Battery Fuse Battery Distribution Battery Discharge Load Disconnect Total Current AC Fail Temp High/Low Float Mode Equalize Mode BTC Active Color Red Red Red Red Red Amber Amber Amber Green Amber Amber Options List # 1 2 20 21 22 30 31 32 33 37 43 46 50 51 52 60 61 62 63 64 65 70 80 100 101 163/8-03/a Description PECO II Part Number Basic bay: -48VDC @ 1200 Amp (208VAC input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .607163P-4 Basic bay: -48VDC @ 1200 Amp (480VAC input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .607163P-5 Rectifier 100 Amp @ 48VDC, 220VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SM100F48PM-1 Rectifier 100 Amp @ 48VDC, 480VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SM100K48PM-1 Rectifier, blank panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4361148P Initial bay kit (required to convert a basic bay into an initial bay) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420525P Gateway communications kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420523P Modem communications kit (requires L31) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420526P Shunt monitoring kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420522P Low voltage load disconnect contactor 1200A for single bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420529P Inner bay connection kit for battery and ground bus bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420527P 6000 Amp external ground window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420537P Fuse panel (15) 3-70 Amp TPS fuse (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6170108P-2 Fuse panel (6) 70-250 Amp TPL fuse (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6170107P-1 Fuse panel (2) 300-600 Amp TPL fuse (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6170109P Circuit breaker panel (18) 2-50 Amp plug-in 1 pole (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180572P Circuit breaker banel (15) 2-100 Amp plug-in 1 pole (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180573P Circuit breaker panel (6) 125-150 Amp plug-in 2 pole (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180582P-1 Circuit breaker panel (4) 100-250 Amp bolt-in 1 pole (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180571P-3 Circuit breaker panel (2) 300-400 Amp bolt-in 2 pole (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180571P-4 Circuit breaker panel (1) 450-700 Amp bolt-in 3 pole (see page 26) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180571P-5 Blank panel, 4 position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4361101P-4 Battery monitor panel (wall mount) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180584P-1 Output load distribution assembly for L63 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180593P Output load distribution assembly for L51 & L62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180593P-1 * See J438163P for complete list of options Specifications are subject to change without notice. Please visit our website for the latest revision. 1200 Amps @ -48VDC Single-Bay, 6000 Amps Multi-Bay 163 Power System Line Drawing 163 Power System is shown Certifications: Specifications are subject to change without notice. Please visit our website for the latest revision. 163/8-03/a 1200 Amps @ -48VDC Single-Bay, 6000 Amps Multi-Bay 163 Power System Circuit Breaker & Fuse Distribution Panels 163/8-03/a Specifications are subject to change without notice. Please visit our website for the latest revision. 1200 Amps @ -48VDC Single-Bay, 6000 Amps Multi-Bay 163 Power System Multi-Bay Configuration Multi-Bay System The 163 1200 Amp bay can be interconnected into a multi-bay system. Up to (5) 1200 Amp bays can be combined to provide 6000 Amp total capacity. Each individual bay can be equipped with up to (12) switchmode rectifiers and 1200 Amps of distribution fuse or breaker panels. Specifications are subject to change without notice. Please visit our website for the latest revision. 163/8-03/a Product Enhancement Announcement Monday August 4, 2003 PECO II, Inc. has just released several enhancements to the 163, a multi-bay –48Vdc, 6000 Amp power plant. In a continuous effort to keep the 163 at the front of the Medium Power Systems class, the following additions have been made: 1. Recognizing the impact of a loss of AC power to a rectifier, PECO II added an AC fail alarm for each rectifier. What makes this feature unique is that the micro is still operational, allowing the controller to communicate with the rectifier. This means the AC power will continuously be monitored. In addition, a visual indicator notifies the user which rectifier is affected. 2. The Battery On Discharge (BOD) alarm is reported as a power major. The corresponding LED is red. 3. To allow the user to distinguish a DC Power Major from a Major caused by a main bay controller (MMC) failure, the Monitor Fail relay is energized in the normal state and deenergized in the alarm state. 4. The web page for the plant displays peak loads and peak load periods, which are stored indefinitely until they are manually cleared. 5. The plant voltage is displayed with two decimal places. 6. The latest software upgrades allow the user to manually initiate individual alarms to verify proper operation. This may be done locally at the site or remotely via the optional Gateway feature. This benefit allows users to test the alarms during preventative maintenance to ensure they would work properly in the event of an actual failure. 7. The Rectifier Count Alarm, which alarms when the number of installed rectifiers does not match the quantity programmed in the controller, can be enabled or disabled by the user (factory default is disabled). 8. There is a Limited Recharge indication, a user settable threshold of the percentage plant discharge current to total plant rectifier capacity. 9. Users can calibrate any monitored analog input. For further information on these enhancements or to inquire about the 163, please contact Kim Burgandine at 800-999-7326 ext. 1228. Visit PECO II, Inc. on the web at www.peco2.com.