Instructions For Installation Of 3671 UNIVERSAL CONTROLLER A6976E I Mounting Instructions 1. Mount exit device per instruction sheet provided. 2. Provide a 3/8” dia. min. raceway to allow insertion of electrical wires running between signal switch and electric hinge. 3. Wiring instructions: See wiring diagram on page 6. USE CONNECTORS ALLOWED BY LOCAL CODE. ALLOW SUFFICIENT LEAD LENGTH FOR REMOVAL OF INSERT. WIRES FROM HINGE RAIL* 55- INSERT 3/8” DIA. HOLES FOR ROUTING WIRES. * Exit Device must be ordered for specific door width. Cutting of rail in field is not recommended. 1 For installation assistance, contact SARGENT at 800-810-WIRE (9473) II Elevation Diagram 1. 2. 3. 4. 5. 6. 7. Exit Device, 80 Series, 55 Prefix Signal Switch Electric Hinge (4 Wire Minimum) Electromagnetic Lock, 24VDC only. .125 mA (1584) Fire Alarm Reset Switch, Momentary N.O. Contact (Optional) Fire Alarm, N.C. Contact (by others - opens upon alarm) Universal Controller - 3671 Power Supply, 24VDC, 1.8 AMP, Regulated (#3510) or 2.0 AMP, Regulated (#3530) 8. Key Switch (4375LH) 9. Door status Switch (3287 - Optional) 10. Optional Remote Release Switch Key Switch 4371LT If Fire Alarm N.C. Contact (item 5) is not used, a jumper must be field installed between terminals IN5, IN7 and COM of Logic Controller 3671. 5 6 2 WIRES 2 WIRES 2 WIRES 2 WIRES 2 WIRES 9 7 WIRES 2 WIRES 10 3 optional 10 WIRES 2 7 4 optional optional 1 For installation assistance, contact SARGENT at 800-810-WIRE (9473) 8 2 III WIRE UNIT ACCORDING TO WIRING DIAGRAM ON PAGE 6. GREEN A. Apply power to the “System”: 1. 2. 3. RED RED RED 1. 2. Insert key into cylinder of 4375LH keyswitch. (2-SPDT momentary switches). Rotate key clockwise. RED LED will illuminate, magnet will de-energize. 3. Rotate key counter clockwise (momentary position) and bring key to center position RED LED illuminates. After 10 seconds (Time delay, factory preset) GREEN LED illuminates. Unit is now armed in a “Delayed Egress Mode”. When rail is depressed, GREEN LED illuminates, RED LED flashes and horn sounds. After 15 seconds, RED LED illuminates solid. See F - Violation. C. “Momentary Egress Mode”: 1. 2. 3. 4. RED Rotate key counter clockwise (full rotation on 4375LH) and return key to center position. RED LED illuminates on keyswitch for ten seconds, magnet de-energizes for momentary authorized egress. After 10 seconds, (time delay expires) the magnet re-energizes and GREEN LED illuminates. Unit is then rearmed in “Delayed Egress Mode”. D. “Maintained Egress Mode”: 1. 2. 3. 4. Rotate key clockwise, return key to center position. You can pull out the key, if desired. RED LED will illuminate. Magnet de-energizes. Unit is in maintained egress mode and operates as a push/pull unit. E. Resetting the unit from “Maintained Egress Mode” to “Delayed Egress Mode”: 1. 2. 3. 4. 3 GREEN LED on 4375LH keyswitch will illuminate. Magnet will energize.(1584) Unit NOT armed. See “Arming System in Delayed Egress Mode”. See B - below. B. Arming the system in “Delayed Egress Mode”: 4. 5. GREEN Universal Controller OPERATING INSTRUCTIONS Rotate key counter clockwise, in 4375LH keyswitch. RED LED illuminates. After 10 seconds (time delay expires), the RED LED will shut off and GREEN LED will illuminate. Magnet energizes. Unit is in “Delayed Egress Mode” (armed position). For installation assistance, contact SARGENT at 800-810-WIRE (9473) OPERATING INSTRUCTIONS CONTINUED F. Violation occurs while in “Delayed Egress Mode” and resetting the unit back in”Delayed Egress Mode” 1. 2. Unit is in “Delayed Egress Mode” (Armed position). Depressing the push bar for more than 2 seconds, starts an irreversible alarm sequence. 3. 4. RED LED flashes on the key switch and GREEN LED illuminates solid. During this process, the magnet remains energized and the alarm on the key switch sounds. 5. After 15 seconds (factory preset delay) the RED LED illuminates solid. GREEN does not illuminate. Magnet de-energizes, allowing egress. Alarm continues to sound until unit is reset by a key at the door. PUSH BAR GREEN RED RED 6. 7. GREEN 8. 9. GREEN 10. 11. 12. RED Insert and rotate key clockwise and return it to center position. Alarm stops sounding, GREEN LED flashes and magnet is still de-energized. Rotate key counter clockwise and return to center position. After 10 seconds (time delay expires) RED LED shuts off and GREEN LED illuminates. Unit is in “Delayed Egress Mode” (armed position). G. Unit tied to a fire alarm: 1. 2. 3. In case of a fire/emergency, the magnet will de-energize instantaneously (voiding the 15 second delay) allowing immediate egress. RED LED illuminates. Resetting the fire alarm automatically sets the unit in a “Delayed Egress Mode” (Armed position). GREEN LED illuminates when a jumper is installed from IN7 to COM. For installation assistance, contact SARGENT at 800-810-WIRE (9473) 4 OPERATING INSTRUCTIONS CONTINUED H. “Door propped” alarm (Requires door status switch-3287): An alarm condition to signal the console and remote location that a door has been held open beyond a factory adjustable time period (0-60 adjustable seconds). Units are preset at the factory for approximately 15 seconds. When a momentary legal release is used, the door is opened, the timer will monitor the “door open” state. If the door remains open beyond the time set: a. The local console alarm and remote alarm will sound b. The station RED LED will remain lit c. The alarm circuitry will not be latched When the door is closed, the alarms will silence. The RED LED will extinguish, and the GREEN LED will illuminate. If the legal release is used during the alarm state, the alarm will silence, the timer will be reset, and the circuitry will resume with the functions of a normal legal release. If Door Status Switch is not used, a jumper from IN6 to COM, must be added. OPTIONAL REMOTE RELEASE • Used to disable system from the exterior of the opening or from security area • Momentary switch 4371LT, located at Terminals IN1 and COM SPECIFICATIONS Input Voltage: Power Consumption: Output Relays: Operating Temp: Enclosure Size: Power Supply: 24 VDC regulated/filtered 300 mA unloaded, 1.5A maximum Form C, 1AMP, 24 VDC -18°C to + 55°C ( 0°F to + 131°F) Steel enclosure with hinged lid, 12"x 12"x 4" Sargent 3510, 24VDC, 1.8A, UL Listed, Class 2 FIRE ALARM APPLICATIONS 1. Fire Alarm with (Normally Open) Momentary Reset Switch (as shown on page 6) Fire alarm contact opens on alarm (Maintained Egress Mode). After alarm condition ceases and Fire Alarm Contact is reset to closed position a momentary switch closure at IN7 to COM is required to reset system back to Delayed Egress mode. 2. Fire Alarm without Momentary Reset Switch Jumper wire must be connected from IN7 to COM. Fire alarm contact opens on alarm (Maintained Egress Mode). After alarm condition ceases and Fire Alarm Contact is reset to closed position the system resets back to Delayed Egress mode automatically. 3. Fire Alarm NOT used Jumper wire must be connected from IN5 to COM and IN7 to COM. 5 For installation assistance, contact SARGENT at 800-810-WIRE (9473) Wiring Diagram For Delayed Egress Applications SARGENT EXIT DEVICE 55-80 SERIES, 3510 POWER SUPPLY, 3671 LOGIC CONTROLLER, 1584 ELECTROMAGNETIC LOCK, AND 4375LH KEY SWITCH +24VDC 3510 1.8 Amp 24VDC Power Supply -24VDC 120VAC IN1* Optional Remote Release COM IN2 COM 3671 Universal Controller IN3 COM IN4 COM IN5* COM Fire Alarm Contact IN8 COM K1 NC C NO NC K8 C NO Return +24 Fire Alarm Reset Earth IN6* COM IN7* COM NC C NO NC 1584 K2 C NO Maglock NC Red LED K3 C NO 4375 NC Green LED K4 C NO 4375 NC K5 C NO NC K6 C NO Horn K7 White (Green LED) (+) Horn Red Black C 3287 Door Status Switch N.C. White (Red LED) (-) Horn Red (Red LED) 1584 Maglock Red (Green LED) SARGENT 4375LH Key Switch EMERGENCY EXIT ONLY Push until alarm sounds. Door can be opened in fifteen seconds Momentary Release Yellow IN3 COM Green IN4 COM Gray Black Red White Maintained Release Electric Hinge 55-80 Series Exit Device NOTES: 1. WIRES MUST BE PROTECTED AGAINST ABRASION. IN4 2. COLORS OF WIRES SHOWN ARE LEADS FROM EXIT DEVICE, COM NOT ELECTRIC HINGE. 3. DOOR STATUS IS (NORMALLY OPEN) HELD CLOSED WHEN DOOR IS CLOSED. IF NOT USED A JUMPER WIRE MUST BE INSTALLED FROM IN6 TO COM. 4. IN3, IN4 ARE NORMALLY OPEN 5. ALL INTERCONNECTING EQUIPMENT MUST BE LOCATED WITHIN THE SAME AREA. 6. CONSULT 3287 INSTRUCTION SHEET FOR PROPER WIRE COLORS. * M SEE NOTES ON PAGE 5 For installation assistance, contact SARGENT at 800-810-WIRE (9473) 6 Wiring From Universal Controller to Optional 4371LT Key Switch Used For Outside Operation SARGENT EXIT DEVICE 55-80 SERIES, 3510 POWER SUPPLY, 3671 LOGIC CONTROLLER, 1584 ELECTROMAGNETIC LOCK, AND 4375LH KEY SWITCH Both Red Wires of the Green and Red LED’s to +24VDC White Wire of Green LED to K4 N.O. of 3671 GRN LED Red Red White Wire of Red LED to K3 N.O. of 3671 RED LED SARGENT Black Wire from Key Switch to +24VDC 7 White Wire from Top of Timer to IN1 of 3671 factory wire from switch to timer Black Wire from Top of Timer to IN1 Com of 3671 Black Wire from Bottom of Timer to -24VDC For installation assistance, contact SARGENT at 800-810-WIRE (9473) TROUBLE SHOOTING 1. Unit does not arm • Check all wire connections • Check position of keyswitch. If GREEN LED is illuminated, magnet should be energized 2. Magnet does not release • Check all wire connections • Fire alarm must be jumped if not using (IN5 and COM) • Disconnect two magnet leads. With OHM meter, measure contacts K2NO and K2 C for continuity For installation assistance, contact SARGENT at 800-810-WIRE (9473) 8 SARGENT Manufacturing Company • 100 Sargent Drive • P.O. Box 9725 • New Haven • CT 06536-0915 Phone: 800-727-5477 • Fax: 888-863-5054 • Website: www.sargentlock.com SARGENT of Canada • Phone: 905-940-2040 • Fax: 905-940-3242 • Website: www.sargentcanada.ca SARGENT® Manufacturing Company is an ASSA ABLOY Group company. Founded in 1864, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products, and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional and industrial markets. The ASSA ABLOY Group is the world’s leading manufacturer and supplier of locks and associated products, dedicated to satisfying end-user needs for security, safety and convenience. An ASSA ABLOY Group company