: Installation of this equipment should only be performed by skilled personnel such as qualified electricians and Certified Renewable Energy (RE) System Installers. 120/240 Vac or 240 Vac only Grid (AC1) Grid (AC1) Inverting Inverting Flashing = sell Gen (AC2) Equalize Flashing = sell Gen (AC2) Fault / Warning Charging Battery Fault / Warning Equalize Charging Battery 24 Vdc or 48 Vdc All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. 975-0238-01-01 Rev A.vsd 4/24/2007 © 2007 Xantrex Technology Inc. The following information is a list of basic steps required to install an XW Inverter/Charger. Actual installation procedures will vary depending upon the configuration of the intended system. xantrex Grid (AC1) Inverting Flashing = sell Gen (AC2) Fault / Warning Equalize Charging Battery Hybrid Inverter/Charger Hybrid Inverter/Charger 24 Vdc or 48 Vdc 975-0238-01-01 Rev A.vsd/SI(6)/April 24, 2007 © 2007 Xantrex Technology Inc. Vented Battery Enclosure All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. xantrex AC LEGEND Grid (AC1) Neutral Inverting Flashing = sell Gen (AC2) Fault / Warning Charging Equalize Battery HOT L1 NEUTRAL HOT L2 L2 L1 Ground GROUND L1 AC OUT AC IN AC IN Inv OUT Grid GEN N L2 L1 N L2 L1 N L2 Hybrid Inverter/Charger (+) (–) (+) (–) ON L1 L2 OFF G N Fuse Block (optional) BATTERY LEGEND FUSE FUSE CLASS TT CLASS 300 AMP AMP 300 Negative (–) Negative (–) Positive (+) Positive (+) 24 Vdc or 48 Vdc xantrex 975-0238-01-01 Rev A.vsd/SI Wiring(7)/April 24, 2007 © 2007 Xantrex Technology Inc. Ground xantrex Grid (AC1) Invertin g Flashin g = sell Gen (AC2) Fault / Warnin g Equaliz e Chargin g Battery xantrex BA PV PV XWBAT Solar Charge T+ – + – Hybrid Inverter/Charger Controller XW Power Distribution Panel XW Conduit Box Battery Bank Vented Battery Enclosure 975-0238-01-01 Rev A.vsd/SI RE Solar(8)/April 24, 2007 © 2007 Xantrex Technology Inc. All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. N xantrex AC LEGEND Grid (AC1) Inverting Flashing = sell Gen (AC2) Fault / Warning Neutral Chargin g Equalize AC Breakers AC Breakers Battery INV 1 IN Bypass (See Note 1) INV 1 OUT GEN HOT L1 xantrex xantrex HOT L2 Ground BAT BAT PV + – – PV + (–) AC OUT AC IN AC IN Inv OUT Grid GEN L1 N L2 L1 N L2 L1 N PV + BAT + PV – BAT – L2 Mppt PV DC Disconnects Hybrid Inverter/Charger (+) (–) L1 L2 G N DC LEGEND Negative (–) 120/240 Vac or 240 Vac only Positive (+) Ground BTS Communication Cable BATTERY LEGEND All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. Negative (–) Battery Temperature Sensor (BTS) 975-0238-01-01 Rev A.vsd/SI RE Wiring (Solar)(9)/April 24, 2007 © 2007 Xantrex Technology Inc. Positive (+) xantrex Ground If no Grid is available, the generator can be connected to the AC breakers in the XW Power Distribution Panel, instead of to a separate AC breaker. Charge/Diversion Load Controller C-Series xantrex Grid (AC1) Invertin g Flashing = sell Gen (AC2) Chargin g Fault / Warning Equaliz e Battery Hybrid Inverter/Charger XW Power Distribution Panel DC In XW Conduit Box 975-0238-01-01 Rev A.vsd/SI RE DL(10)/April 24, 2007 © 2007 Xantrex Technology Inc. Vented Battery Enclosure All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. XW Inverter/Charger Communication Ports L2 G N BTS CM/CMR BAT POS L1 PV/Load POS COM NEG COM NEG (on Bottom of Inverter) N xantrex AC Breakers INV 1 IN Bypass (See Note 1) GEN INV 1 OUT AC LEGEND Neutral HOT L1 (–) HOT L2 Ground L1 AC OUT AC IN AC IN Inv OUT Grid GEN N L2 L1 N L2 L1 N DC Disconnect L2 Mppt PV Hybrid Inverter/Charger All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. If no Grid is available, the generator can be connected to the AC breakers in the XW Power Distribution Panel, instead of to a separate AC breaker. 975-0238-01-01 Rev A.vsd/SI RE DL Wiring(11)/April 24, 2007 © 2007 Xantrex Technology Inc. Vented Battery Enclosure xantrex xantrex Grid (AC1) Equaliz e Grid (AC1) Invertin g Flashin g = sell Gen (AC2) Fault / Warnin g xantrex Invertin g Flashin g = sell Gen (AC2) Fault / Warnin g Chargin g Equaliz e Battery Chargin g Battery xantrex PVCharge Controller PV XW Solar BAT BAT + – Hybrid Inverter/Charger Hybrid Inverter/Charger – + XW Power Distribution Panel xantrex PVCharge Controller PV XW Solar BAT BAT + – XW Conduit Box 975-0238-01-01 Rev A.vsd/DI RE Solar(12)/April 24, 2007 © 2007 Xantrex Technology Inc. – + XW Conduit Box Vented Battery Enclosure All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. AC LEGEND N xantrex xantrex AC Breakers INV 1 IN (Grid) INV 2 IN (Grid) Grid Bypass L2 G N XW Solar Charge Controller Neutral HOT L1 L1 (See Note 1) Grid Bypass INV 1 OUT (AC Loads) INV 2 OUT (AC Loads) INV 1 IN (Gen) INV 2 IN (Gen) HOT L2 xantrex Ground Inverter AC Distribution Panel NEUTRAL L2 L1 BAT BAT PV PV + – – + (–) AC OUT AC IN AC IN AC OUT AC IN AC IN Inv OUT Grid GEN Inv OUT Grid GEN L1 N L2 L1 N L2 L1 N L1 L2 N L2 L1 N L2 L1 N L2 CC + Hybrid Inverter/Charger CC + Mppt PV PV + PV + DC Disconnects GROUND Hybrid Inverter/Charger xantrex BAT BAT PV PV + – – + DC LEGEND If no Grid is available, the generator can be connected to the AC breakers in the XW Power Distribution Panel, instead of to a separate AC breaker. 975-0238-01-01 Rev A.vsd/DI RE Solar Wiring(13)/April 24, 2007 © 2007 Xantrex Technology Inc. xantrex 24 Vdc or 48 Vdc BATTERY LEGEND Negative (–) Negative (–) Positive (+) Positive (+) Ground Ground xantrex Grid (AC1) Charge/Diversion Load Controller Charge/Diversion Load Controller C-Series C-Series xantrex Grid (AC1) Inverting Inverting Flashing = sell Flas hing = sell Gen (AC2) Gen (AC2) Fault / Warning Fault / Warning Charging Equalize Charging Equalize Battery Battery Hybrid Inverter/Charger XW Power Distribution Panel Communication Hybrid Inverter/Charger DC In XW Conduit Box 975-0238-01-01 Rev A.vsd/DI RE DL(14)/April 24, 2007 © 2007 Xantrex Technology Inc. XW Conduit Box All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. All configurations must comply with local and national electrical code jurisdiction. Consult your local certified installer or local electrical authority to ensure compliance. L2 G N BTS CM/CMR BAT POS L1 PV/Load POS COM NEG COM NEG N xantrex xantrex Grid (AC1) Inverting Flashing = sell Gen (AC2) Fault / Warning Charging AC Breakers (See Note 1) Equalize Battery INV 1 IN (Grid) INV 2 IN (Grid) Grid Bypass Grid Bypass INV 1 OUT (AC Loads) INV 2 OUT (AC Loads) INV 1 IN (Gen) INV 2 IN (Gen) (–) AC OUT AC IN AC IN AC OUT AC IN AC IN Inv OUT Grid GEN Inv OUT Grid GEN L1 N L2 L1 N L2 L1 N L1 L2 N L2 L1 N L2 L1 N L2 Mppt PV DC Disconnects Hybrid Inverter/Charger Hybrid Inverter/Charger BTS Communication Cable If no Grid is available, the generator can be connected to the AC breakers in the XW Power Distribution Panel, instead of to a separate AC breaker. xantrex 975-0238-01-01 Rev A.vsd/DI RE DL Wiring(15)/April 24, 2007 © 2007 Xantrex Technology Inc. Battery Temperature Sensor (BTS) Vented Battery Enclosure