Custom Power Supply Cords

advertisement
Custom Power Supply Cords
How to Specify a Custom Power Cord/Harness
If you already have a power cord specification and blueprint, it is still helpful if you identify our plug, connector and wire
that is acceptable. Either note our catalog number on your print or fill in the SPECIFICATION SHEET on page 80 and
attach it to your print. Proceed directly to STEP 2.
Step 1: Determining Information
A. Identify type of cord required:
1. Power Supply Cord - Male plug for standard outlet or receptacle.
2. Detachable Power Supply Cord - Standard male plug, female connector.
3. Extension Cord - Standard NEMA male plug and female connector.
4. Wiring Harness - Free ends without plug or connector, on both or one end only, or with terminals or with special
non-standard connectors.
B. Required Approvals:
1. For products to be sold in U.S. and Canada, refer to the applicable UL and CSA Standard for designation of cord
types, materials, temperature ratings, etc. required for your application.
2. For products to be sold outside of North America, check with agencies in countries where product is to be used to
determine requirements for product approval as well as designated cord types, constructions, etc.
C. Copper Conductor Size - as defined by applicable standard and based on load requirments (amperage), select the
appropriate AWG or metric size copper needed.
D. Cord Type - Select a cord from the approval agency’s product standard, taking into consideration dimensions,
flexibility, special requirements and cost (SVT, SJT, SPT, etc.)
E. Male Plugs and/or Female Connectors
1. For North American power supply cord applications, refer to the NEMA Chart in our Technical Section for the
standard configuration and identifying number (1-15P, 5-15P, etc.) you require. Match with Unicable configuration
of available plug styles.
2. On International Style power supply cords, refer to International plug configuration section to match cord and load
requirements.
3. Special Molded plugs/connectors may also be available. Check with your Unicable Customer Service
Administrator for specific requirements.
Determine overall length, color and open-end finish required.
Step 2: Will a Unicable stock cord meet your needs or is a custom cord necessary?
A. If a Stock Cord satisfies your requirements, identify by stock part number and contact your Unicable Sales
Administrator for price and delivery.
B. If unsure whether a Stock Cord will suffice, proceed to STEP 3. If Unicable determines a Stock Cord can be used, we
will advise you in our quote.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
29
Custom Power Supply Cords
How to Specify a Custom Power Cord/Harness
Step 3: Product Specification Sheet
A. Refer to “How to Specify Power Cords” on page 80 for a basic guideline on terms used, options on free ends and
packaging.
B. Fill out the SPECIFICATION SHEET up to 1.
C. 1. Wire Type - describe wire type as follows:
a. AWG or metric size copper size (18awg or 1.0mm², etc.)
b. Number of conductors - two or three.
c. Cord type - SVT, STO, water resistant, etc., or LIGHT DUTY, ORDINARY DYT, etc.
d. If termperature rating is other than the standard 60ºC, you must indicate what rating is required.
D. “A” End - Based on STEP 1, Section E, insert Unciable’s plug configuration number for the plug/connector desired.
New tooling may be required for special plugs.
E. “B” End - Fill in the appropriate blank spaces as indicated using “End Process of Cords,” Page 79, as a guideline.
F. Overall Length - Length should be measured from the face of the plug/connector, or from the furthest tip of the leads,
to the furthest tip of the “B” end.
G. Color - if possible, select a standard color, as custom colors often cost more, increase minimums, and lengthen lead
times.
H. Packaging
1. A machine hanked cord is most expensive.
2. A tied-loop-hanked or coil and tied is medium cost.
3. Bulk packaging is the least expensive.
I. Strain Relief - For Power Supply Cords either a mechanical, or molded-on device is required to meet agency pull
tests.
1. Entrance holes or slot have to be at parting line or case for assembly. Molded-on strain reliefs should not be
inserted into pre-cut holes.
2. Select slot width necessary to accomodate housing thickness. You should submit to us the portion of your
housing where the strain relief is assembled in order for us to design a precise fit as quickly as possible.
J. Other - Fill in the application of the cord, or what type of product the cord is being designed for. Attach any product
literature available.
K. To ensure an accurate and prompt quotation, please include samples (if possible), your prints (if available) or at the
minimum a filled in Product Specification Sheet. Send a complete package either through our Area Representative or
directly to our Sales Department.
30
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 1-15P PLUG (POLARIZED OR
NON-POLARIZED)
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-001
Applicable Wire Type/Size:
20/2 AWG (4A/125V): XT, XTW
18/2 AWG (10A/125V): HPN, SPT-1, NISPT-1, SPT-2, NISPT-2
16/2 AWG (13A/125V): SPT-2, SPT-2W
16/2 AWG (15A/125V): HPN
CONFIGURATION STANDARD: NEMA 1-15P PLUG WITH CORD GRIP
(POLARIZED OR NON-POLARIZED)
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-01A
Applicable Wire Type/Size:
20/2 AWG (4A/125V): XT, XTW
18/2 AWG (10A/125V): HPN, SPT-1, NISPT-1, SPT-2, NISPT-2,
16/2 AWG (13A/125V): SPT-2, SPT-2W
16/2 AWG (15A/125V): HPN
CONFIGURATION STANDARD: NEMA 1-15P PLUG (POLARIZED OR
NON-POLARIZED)
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-01B
Applicable Wire Type/Size:
18/2 AWG (10A/125V): HPN, SPT-1, SPT-2
16/2 AWG (13A/125V): SPT-2
16/2 AWG (15A/125V): HPN
UC-002
CONFIGURATION STANDARD: FAN PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 10A/5A
VOLTAGE: 125V/250V
Applicable Wire Type/Size:
18/2 AWG (10A/125V, 5A/250V): SPT-1, SPT-2
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
31
Plugs & Connectors
UC-02A
CONFIGURATION STANDARD: RIGHT ANGLE FAN PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 10A/5A
VOLTAGE: 125V/250V
Applicable Wire Type/Size:
18/2 AWG (10A/125V, 5A/250V): SPT-1, SPT-2
UC-02B
CONFIGURATION STANDARD: RIGHT ANGLE FAN PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 10A/5A
VOLTAGE: 125V/250V
Applicable Wire Type/Size:
18/2 AWG (10A/125V, 5A/250V): SPT-1, SPT-2
UC-02C
CONFIGURATION STANDARD: RIGHT ANGLE FAN PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 10A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SPT-1, SPT-2
UC-02D
CONFIGURATION STANDARD: ULTRASONIC WELDED FAN
PLUG WITH 45º ANGLE
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SPT-1, SPT-2
32
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: NON-POLARIZED CONNECTOR, 2.3 DIA. CONTACT
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 7A
VOLTAGE: 125V
UC-003
Applicable Wire Type/Size:
20/2 AWG (4A/125V): XT
18/2 AWG (7A/125V): SPT-1, NISPT-1, SPT-2, NISPT-2
CONFIGURATION STANDARD: POLARIZED CONNECTOR, 2.3 DIA. CONTACTS
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 7A/2.5A
VOLTAGE: 125V/250V
UC-03A
Applicable Wire Type/Size:
20/2 AWG (4A/125V): XT
18/2 AWG (7A/125V, 2.5A/250V): SPT-1, NISPT-1, SPT-2, NISPT-2
UC-03C
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C7 CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 7A/2.5A
VOLTAGE: 125V/250V
Applicable Wire Type/Size:
18/2 AWG (7A/125V, 2.5A/250V):
UC-03C/H
SPT-1, NISPT-1, SPT-2, NISPT-2
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C7 CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA), DEMKO (DENMARK),
FIMKO (FINLAND), IMQ (ITALY), KEMA (NETHERLANDS), NEMKO (NORWAY),
OVE (AUSTRIA), SEMKO (SWEDEN), SEV (SWITZERLAND), VDE (GERMANY),
CE (EUROPE), SAA (AUSTRALIA)
AMPERAGE: 7A/2.5A
VOLTAGE: 125V/250V
Applicable Wire Type/Size:
18/2 AWG (7A/125V, 2.5A/250V): SPT-1, NISPT-1, SPT-2, NISPT-2
0.75mm2 (2.5A/250V): H03VVH2-F, H05VVH2-F
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
33
Plugs & Connectors
UC-03C/U
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C7 CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 7A/2.5A
VOLTAGE: 125V/250V
Applicable Wire Type/Size:
18/2 AWG (7A/125V, 2.5A/250V):
UC-03D
SPT-1, NISPT-1, SPT-2, NISPT-2
CONFIGURATION STANDARD: NON-POLARIZED CONNECTOR, 2.3 DIA. CONTACTS
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 7A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/2 AWG (7A/125V): SPT-1, NISPT-1, SPT-2, NISPT-2
UC-03E
CONFIGURATION STANDARD: POLARIZED CONNECTOR, 2.3/2.6 DIA. CONTACTS
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 7A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/2 AWG (7A/125V): SPT-1, NISPT-1, SPT-2, NISPT-2
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C7 RIGHT ANGLE
CONNECTOR
APPROVALS: UL (AMERICA). CUL (CANADA), CSA (CANADA)
AMPERAGE: 7A/2.5A
VOLTAGE: 125V/250V
UC-03F
Applicable Wire Type/Size:
18/2 AWG (7A/125V, 2.5A/250V): SPT-1, NISPT-1, SPT-2, NISPT-2
34
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
UC-03H
CONFIGURATION STANDARD: NON-POLARIZED CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 10A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SPT-2
CONFIGURATION STANDARD: NEMA 5-15P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-004
Applicable Wire Type/Size:
18/3 AWG (10A/125V):SPT-1, SPT-2, SPT-3, S, SO, SJ, SJO, SVT, SVTO, SJT,
SVT SHIELDED, SJT SHIELDED, SJTW, STO, STOW, ST, STW,SJTO, SJTOW,
HPN
17/3 AWG (12A/125V):SPT-1, SPT-2, SPT-3, S, SO, SJ, SJO, SVT, SVTO,
SVT SHIELDED, SJTW, STO, STOW, ST, STW, SJTO,SJTOW, HPN
16/3 AWG (13A/125V):SPT-2, SPT-3, SJT, S, SO, SJ, SJO, SJT SHIELDED,
SJTW,ST, STW, STO, STOW, SJTO, SJTOW16/3 AWG (15A/125V): HPN
14/3 AWG (15A/125V):S, SO, SJ, SJO, SJT SHIELDED, SJTW, SJTO, SJTOW,
ST,STW, STO, STOW, SPT-3
12/3 AWG (15A/125V):S, SO, SJ, SJO, SJT, SJTW, ST, STW, STO, STOW, SPT-3
CONFIGURATION STANDARD: NEMA 5-15P PLUG WITH CORD GRIP
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
UC-04A
18/3 AWG (10A/125V): SVT, STW, SPT-2, SPT-3, SVT SHIELDED, SJT,
SVT SHIELDED, SJT SHIELDED, SJTW, STO, STOW, SJTO, SJTOW, HPN
17/3 AWG (12A/125V): SVT, STW, SPT-2, SPT-3, SVT SHIELDED, SJT,
SJT SHIELDED, SJTW, ST, STW, SJTW, STO, STOW, SJTO, SJTOW, HPN
16/3 AWG (13A/125V): SJT, SJT SHIELDED, SJTW, ST, STW, STO,
STOW, SJTO, SJTOW
16/3 AWG (15A/125V): HPN
14/3 AWG (15A/125V): SJT, SJT SHIELDED, SJTW, SJTO, SJTOW,
ST, STW, STO, STOW, SPT-3
12/3 AWG (15A/125V): SJT, SJTW, ST, STW, STO, STOW, SPT-3
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
35
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 5-15P PLUG WITH SHROUD
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-04B
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SJT, SJTW
17/3 AWG (12A/125V): SJT, SJTW
16/3 AWG (13A/125V): SJT, SJTW
14/3 AWG (15A/125V): SJT, SJTW
CONFIGURATION STANDARD: NEMA 5-15P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/3 AWG (10A/125V):SPT-1, SPT-2, SPT-3, S, SO, SJ, SJO, SVT, SVTO, SJT,
SVT SHIELDED, SJT SHIELDED, SJTW, STO, STOW, ST, STW,SJTO, SJTOW, HPN
17/3 AWG (12A/125V):SPT-1, SPT-2, SPT-3, S, SO, SJ, SJO, SVT, SVTO,
SVT SHIELDED, SJTW, STO, STOW, ST, STW, SJTO,SJTOW, HPN
UC-04C
16/3 AWG (13A/125V):SPT-2, SPT-3, SJT, S, SO, SJ, SJO, SJT SHIELDED,
SJTW,ST, STW, STO, STOW, SJTO, SJTOW
16/3 AWG (15A/125V): HPN
14/3 AWG (15A/125V):S, SO, SJ, SJO, SJT SHIELDED, SJTW, SJTO, SJTOW,
ST,STW, STO, STOW, SPT-3
12/3 AWG (15A/125V):S, SO, SJ, SJO, SJT, SJTW, ST, STW, STO, STOW, SPT-3
CONFIGURATION STANDARD: NEMA 5-15P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
UC-04D
18/3 AWG (10A/125V): SVT, SJT, ST, SJ, SV, SV SHIELDED, SVTO, SJTW, SJTO,
SJTOW, STW, STO, STOW, SJO, SJOW, SJOOW, SJW, SVO, SVOW, SVW, SO,
SOO,SOOW, SOW, HS, HSO, HSJ, HSJO
17/3 AWG (12A/125V): SVT, SJT, ST, SJ, SV, SV SHIELDED, SVTO, SJTW, SJTO,
SJTOW, STW, STO, STOW, SJO, SJOW, SJOOW, SJW, SVO, SVOW, SVW, SO,
SOO, SOOW, SOW, HS, HSO, HSJ, HSJO
16/3 AWG (13A/125V): SVT, SJT, ST, SJ, SV, SV SHIELDED, SVTO, SJTW, SJTO,
SJTOW, STW, STO, STOW, SJO, SJOW, SJOOW, SJW, SVO, SVOW, SVW, SO,
SOO, SOOW, SOW, HS, HSO, HSJ, HSJO
14/3 AWG (15A/125V): SJT, SJ, ST, ST SHIELDED, SJTW, SJTO, SJTOW, STW,
STO, STOW, SJO, SJO, SJOW, SJOOW, SJW, SO, SOO, SOOW, SOW, HS, HSO,
HSJ, HSJO
12/3 AWG (15A/125V): SJT, SJ, ST, ST SHIELDED, SJTW, SJTO, SJTOW, STW,
STO, STOW, SJO, SJO, SJOW, SJOOW, SJW, SO, SOO, SOOW, SOW, HS, HSO,
HSJ, HSJO
36
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 5-15P PLUG WITH CORD GRIP
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, ST, SJ, SV, SV SHIELDED, SVTO, SJTW, SJTO,
SJTOW, STW, STO, STOW, SJO, SJOW, SJOOW, SJW, SVO, SVOW, SVW, SO,
SOO,SOOW,SOW, HS, HSO, HSJ, HSJO
UC-04E
17/3 AWG (12A/125V): SVT, SJT, ST, SJ, SV, SV SHIELDED, SVTO, SJTW, SJTO,
SJTOW, STW, STO, STOW, SJO, SJOW, SJOOW, SJW, SVO, SVOW, SVW, SO, SOO,
SOOW, SOW, HS, HSO, HSJ, HSJO
16/3 AWG (13A/125V): SVT, SJT, ST, SJ, SV, SV SHIELDED, SVTO, SJTW, SJTO,
SJTOW, STW, STO, STOW, SJO, SJOW, SJOOW, SJW, SVO, SVOW, SVW, SO, SOO,
SOOW, SOW, HS, HSO, HSJ, HSJO
14/3 AWG (15A/125V): SJT, SJ, ST, ST SHIELDED, SJTW, SJTO, SJTOW, STW, STO,
STOW, SJO, SJO, SJOW, SJOOW, SJW, SO, SOO, SOOW, SOW, HS, HSO, HSJ,
HSJO
12/3 AWG (15A/125V): SJT, SJ, ST, ST SHIELDED, SJTW, SJTO, SJTOW, STW, STO,
STOW, SJO, SJO, SJOW, SJOOW, SJW, SO, SOO, SOOW, SOW, HS, HSO, HSJ,
HSJO
CONFIGURATION STANDARD: NEMA 5-15P PLUG FOR 1" DIA. HOLE
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-04M
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SPT-1, SPT-2, SPT-3, S, SO, SJ, SJO, SVT, SVTO, SJT,
SVT SHIELDED, SJT SHIELDED, SJTW, STO, STOW, ST, STW, SJTO, SJTOW, HPN
17/3 AWG (12A/125V): SPT-1, SPT-2, SPT-3, S, SO, SJ, SJO, SVT, SVTO,
SVT SHIELDED, SJTW, STO, STOW, ST, STW, SJTO, SJTOW, HPN
16/3 AWG (13A/125V): SPT-2, SPT-3, SJT, S, SO, SJ, SJO, SJT SHIELDED, SJTW,
ST, STW, STO, STOW, SJTO, SJTOW
16/3 AWG (15A/125V): HPN
14/3 AWG (15A/125V): S, SO, SJ, SJO, SJT SHIELDED, SJTW, SJTO, SJTOW, ST,
STW, STO, STOW, SPT-3
12/3 AWG (15A/125V): S, SO, SJ, SJO, SJT, SJTW, ST, STW, STO, STOW, SPT-3
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
37
Plugs & Connectors
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-005
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, NISPT-2, S, SO, SVT, SVT SHIELDED, SJT
SJT SHIELDED, SJTO, SJTOW, SJTW, ST, STO, STOW
16/3 AWG (13A/250V): SPT-2, NISPT-2, SJT, SJTOW, SJTW, SJT SHIELDED
ST, STO, STOW
14/3 AWG (15A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA), DEMKO (DENMARK),
FIMKO (FINLAND), IMQ (ITALY), KEMA (NETHERLANDS), NEMKO (NORWAY),
OVE (AUSTRIA), SEMKO (SWEDEN), SEV (SWITZERLAND), VDE (GERMANY),
CE (EUROPE), SAA (AUSTRALIA)
AMPERAGE: 15A (N. AMERICA), 10A (EUROPE, AUSTRALIA)
VOLTAGE: 250V
UC-05I
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, SVT, SVT SHIELDED, SJT, SJT SHIELDED, SJTO
SJTO, SJTOW, SJTW, STO
16/3 AWG (13A/250V): SPT-2, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/3 AWG (15A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (10A/250V): H05VV-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C15 CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-05A
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, NISPT-2, SJ, SO, SJT, SOW, SOOW, SJO, SJOO,
SJOOW, SVTO, SVT, SVT SHIELDED, SJT SHIELDED, SJTO, SJTOW, SJTW,
SJT, HS, HSO, HSJO
16/3 AWG (13A/250V): SPT-2, NISPT-2, SJ, SO, SOW, SOOW, SJO, SJOO, SJOOW,
SVTO, SJT, SJTO, SJTOW, SJTW, SJT SHIELED, HS, HSO, HSJO
14/3 AWG (15A/250V): SJ, SO, SOW, SOOW, SJO, SJOO, SJOOW, SJT, SJTO,
SJTOW, SJTW, SJT SHIELDED, HS, HSO, HSJO
38
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: EUROPEAN IEC
60320/C15 CONNECTOR
APPROVALS: PENDING
AMPERAGE: 10A
VOLTAGE: 250V
UC-05AI
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05RR-F, H05RN-F
1.00mm2 (10A/250V): H05RR-F, H05RN-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C17
CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-05C
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, NISPT-2, SVT SHIELDED, SJT, SJT SHIELDED
16/3 AWG (13A/250V): SPT-2, NISPT-2, SJT, SJT SHIELDED
14/3 AWG (15A/250V): SJT, SJT SHIELDED
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C17
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), IMQ (ITALY),
KEMA (NETHERLANDS), NEMKO (NORWAY), OVE (AUSTRIA), SEMKO (SWEDEN),
SEV (SWITZERLAND), VDE (GERMANY), CE (EUROPE
AMPERAGE: 10A
VOLTAGE: 250V
UC-05CI
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
UC-05E
CONFIGURATION STANDARD: EUROPEAN IEC 60320/17 CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 13A
VOLTAGE: 250V
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SVT SHIELDED
16/3 AWG (13A/250V): SVT, SVT SHIELDED, SJT, SJT SHIELDED
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
39
Plugs & Connectors
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C15 PHENOLIC CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A/10A
VOLTAGE: 125V/250V
UC-05P
Applicable Wire Type/Size:
18/3 AWG (10A/125V, 10A/250V): SPT-2, SJT, HPN
16/3 AWG (13A/125V, 10A/250V): SPT-2, SJT
16/3 AWG (15A/125V, 10A/250V): HPN
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 RIGHT
ANGLE CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-006
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, SVT, SVTO, SVT SHIELDED, SJT SHIELDED, SJTO,
SJTOW, SJTW, SJT, ST
16/3 AWG (13A/250V): SPT-2, ST, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/3 AWG (15A/250V): ST, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 RIGHT ANGLE
CONNECTOR
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), OVE (AUSTRIA),
NEMKO (NORWAY), SEMKO (SWEDEN), SEV (SWITZERLAND),
KEMA (NETHERLANDS), VDE (GERMANY), CE (EUROPE), SAA (AUSTRALIA)
AMPERAGE: 10A
VOLTAGE: 250V
UC-06I
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (10A/250V): H05VV-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C15 RIGHT ANGLE
CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-06A
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, SVT, SVT SHIELDED, SJT SHIELDED, SJTO
SJTOW, SJT
16/3 AWG (13A/250V): SPT-2, SJT, SJTO, SJTOW, SJT SHIELDED
14/3 AWG (15A/250V): SJT, SJTO, SJTOW, SJTWW, SJT SHIELDED
40
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C15 RIGHT ANGLE
CONNECTOR
APPROVALS: PENDING
AMPERAGE: 10A
VOLTAGE: 250V
UC-06AI
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05RR-F, H05RN-F
1.00mm2 (10A/250V): H05RR-F, H05RN-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C17 RIGHT ANGLE
CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-06C
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SJT, SVT SHIELDED, SJT, SJT SHIELDED
16/3 AWG (13A/250V): SJT, SJT SHIELDED
14/3 AWG (15A/250V): SJT, SJT SHIELDED
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C17 RIGHT ANGLE
CONNECTOR
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), KEMA (NETHERLANDS),
NEMKO (NORWAY), OVE (AUSTRIA), SEMKO (SWEDEN), SEV (SWITZERLAND),
VDE (GERMANY), CE (EUROPE)
AMPERAGE: 10A
VOLTAGE: 250V
UC-06CI
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VVH2-F, H05VV-F
1.00mm2 (10A/250V): H05VV-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 LEFT ANGLE
CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-06L
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, SVT, SVTO, SVT SHIELDED, SJT SHIELDED, SJTO,
SJTOW, SJTW, SJT, ST
16/3 AWG (13A/250V): SPT-2, ST, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/3 AWG (15A/250V): ST, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
41
Plugs & Connectors
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 LEFT ANGLE
CONNECTOR
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), KEMA (NETHERLANDS),
NEMKO (NORWAY), OVE (AUSTRIA), SEMKO ( SWEDEN), SEV (SWITZERLAND),
VDE (GERMANY), CE (EUROPE), SAA (AUSTRALIA)
AMPERAGE: 10A
VOLTAGE: 250V
UC-06LI
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (10A/250V): H05VV-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 RIGHT ANGLE
CONNECTOR, LOW PROFILE
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-06M
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, SVT, SVTO, SVT SHIELDED, SJT SHIELDED, SJTO,
SJTOW, SJTW, SJT, ST
16/3 AWG (13A/250V): SPT-2, ST, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/3 AWG (15A/250V): ST, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
CONFIGURATION STANDARD: EUROPEAN IEC 6032/C13 RIGHT ANGLE
CONNECTOR, LOW PROFILE
APPROVALS: SAA (AUSTRALIA)
AMPERAGE: 10A
VOLTAGE: 250V
UC-06MI
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F 3G
1.00mm2 (10A/250V): H05VV-F 3G
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 LEFT ANGLE
CONNECTOR, LOW PROFILE
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-06ML
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SPT-2, SVT, SVTO, SVT SHIELDED, SJT SHIELDED,
SJTO,SJTOW, SJTW, SJT, ST
16/3 AWG (13A/250V): SPT-2, ST, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/3 AWG (15A/250V): ST, SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
42
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C13 LEFT ANGLE
CONNECTOR, LOW PROFILE
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), IMQ (ITALY),
KEMA (NETHERLANDS), NEMKO (NORWAY), OVE (AUSTRIA),
SEMKO (SWEDEN), SEV (SWITZERLAND), VDE (GERMANY), CE (EUROPE),
SAA (AUSTRALIA)
AMPERAGE: 10A
VOLTAGE: 250V
UC-06MLI
Applicable Wire Type/Size:
1.00mm2 (10A/250V): H05VV-F
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-07A
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW,
SPT-1, SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW, SPT-2, SPT-3
14/3 AWG (15A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW, SPT-3
12/3 AWG (15A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW, SPT-3
CONFIGURATION STANDARD: NEMA 6-20P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 20A
VOLTAGE: 250V
UC-07B
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SPT-2, SPT-3, SJT, SJTW, SJTO, SJTOW, ST, STW,
STO, STOW
16/3 AWG (13A/250V): SPT-2, SPT-3, SJT, SJTW, SJTO, SJTOW, ST, STW,STO, STOW
14/3 AWG (18A/250V): SPT-3, SJT, SJTW, SJTO, SJTOW, ST, STW,STO, STOW
12/3 AWG (20A/250V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW, SPT-3
CONFIGURATION STANDARD: NEMA 6-15P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-07C
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SPT-2, SPT-3, SJT, SJTW, SJTO, SJTOW, ST, STW,
STO, STOW
16/3 AWG (13A/250V): SJT, SJTW, SPT-2, SPT-3, SJTO, SJTOW, ST, STW,STO, STOW
14/3 AWG (15A/250V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW, SPT-3
12/3 AWG (15A/250V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW, SPT-3
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
43
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 5-20P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 20A
VOLTAGE: 125V
UC-07D
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO, SJTOW, ST,STW, STO, STOW, SPT-2,
SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW,STO, STOW, SPT-2, SPT-3
14/3 AWG (18A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW,STO, STOW, SPT-3
12/3 AWG (20A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW,STO, STOW, SPT-3
CONFIGURATION STANDARD: NEMA 5-20P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 20A
VOLTAGE: 125V
UC-07F
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO, SJTOW, ST,STW, STO, STOW, SPT-2,
SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW, SPT-2, SPT-3
14/3 AWG (18A/125V): S, SO, SOW, SOOW, SJ, SJO, SJOW, SJOOW,SJT, SJTW,
SJTO, SJTOW, ST, STW, STO, STOW, SPT-3
12/3 AWG (20A/125V): S, SO, SOW, SOOW, SJ, SJO, SJOW, SJOOW,SJT, SJTW,
SJTO, SJTOW, ST, STW, STO, STOW, SPT-3
CONFIGURATION STANDARD: NEMA 6-15P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-07G
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SPT-2, SPT-3, S, SO, SJ, SJO, SJT,SJTW, SJTO, SJTOW,
ST, STW, STO, STOW
16/3 AWG (13A/250V): SPT-2, SPT-3, S, SO, SJ, SJO, SJT, SJTW, SJTO, SJTOW, ST,
STW, STO, STOW
14/3 AWG (15A/250V): SJT, SJTW, SJTO, SJTOW, S, SO, SJ, SJO, ST, STW, STO,
STOW, SPT-3
12/3 AWG (15A/250V): SJT, SJTW, SJTO, SJTOW, S, SO, SJ, SJO, ST, STW, STO,
STOW, SPT-3
44
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 6-20P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 20A
VOLTAGE: 250V
UC-07H
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SPT-2, SPT-3, SJT, SJTW, SJTO, SJTOW,ST, STW, STO,
STOW
16/3 AWG (13A/250V): SPT-2, SPT-3, SJT, SJTW, SJTO, SJTOW, ST,STW, STO, STOW
14/3 AWG (18A/250V): SPT-3, SJT, SJTW, SJTO, SJTOW, ST, STW,STO, STOW
12/3 AWG (20A/250V): SPT-3, SJT, SJTW, SJTO, SJTOW, ST, STW,STO, STOW
CONFIGURATION STANDARD: NEMA 1-15P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SJ, SJO, SJOW, SJW, SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, SVTO, ST, STW, STO,
STOO, STOW, SPT-3
UC-008
17/2 AWG (12A/125V): SJ, SJO, SJOW, SJW, SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, SVTO, ST, STW, STO,
STOO, STOW, SPT-3
16/2 AWG (13A/125V): SJ, SJO, SJOW, SJW, SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, ST, STW, STO, STOO,
STOW, SPT-3
14/2 AWG (15A/125V): SJ, SJO, SJOW, SJW, SO, SOO, SOOW, SOW, SJT, SJTW,
SJTO, SJTOO, SJTOW, SJTOOW, ST, STW, STO, STOO, STOW, SPT-3, HPN
CONFIGURATION STANDARD: NEMA 1-15P PLUG, WITH CORD GRIP
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-08B
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SJ, SJO, SJOW, SJW, SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, SVTO, ST, STW, STO,
STOO, STOW, SPT-3
17/2 AWG (12A/125V): SJ, SJO, SJOW, SJW, SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, SVTO, ST, STW, STO,
STOO, STOOW, STOW, SPT-3
16/2 AWG (13A/125V): SJ, SJO, SJOW, SJW, SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, ST, STW, STO, STOO,
STOOW, STOW, SPT-3
14/2 AWG (15A/125V): SJ, SJO, SJOW, SJW, SO, SOO, SOOW, SOW, SJT, SJTW,
SJTO, SJTOO, SJTOW, SJTOOW, ST, STW, STO, STOO, STOOW, STOW, SPT-3
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
45
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 1-15P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-08C
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SJ, SJO, SJOW, SJW#44 SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, SVTO, ST, STW, STO,
STOO, STOW, SPT-3
17/2 AWG (12A/125V): SJ, SJO, SJOW, SJW#44 SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, SVTO, ST, STW, STO,
STOO, STOW, SPT-3
16/2 AWG (13A/125V): SJ, SJO, SJOW, SJW#44 SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, ST, STW, STO, STOO,
STOW, SPT-3
14/2 AWG (15A/125V): SJ, SJO, SJOW, SJW#44 SO, SOO, SOOW, SOW, SJT, SJTW,
SJTO, SJTOO, SJTOW, SJTOOW, ST, STW, STO, STOO, STOW, SPT-3, HPN
CONFIGURATION STANDARD: NEMA 1-15P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-08CS
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SJ, SJO, SJOW, SJW#44 SO, SOW, SOO, SOOW,SJT, SJTW,
SJTO, SJTOW, SJTOO, SJTOOW, ST, STW, STO, STOW, STOO, STOOW, SVT, SVTO,
SV, SVO, SPT-3
17/2 AWG (12A/125V): SJ, SJO, SJOW, SJW#44 SO, SOW, SOO, SOOW,SJT, SJTW,
SJTO, SJTOW, SJTOO, SJTOOW, ST, STW, STO, STOW, STOO, STOOW, SVT, SVTO,
SV, SVO, SPT-3
16/2 AWG (13A/125V): SJ, SJO, SJOW, SJW#44 SO, SOW, SOO, SOOW,SJT, SJTW,
SJTO, SJTOW, SJTOO, SJTOOW, ST, STW, STO, STOW, STOO, STOOW, SVT, SV,
SVO, SPT-3
14/2 AWG (15A/125V): SJ, SJO, SJOW, SJW#44 SO, SOW, SOO, SOOW,SJT, SJTW,
SJTO, SJTOW, SJTOO, SJTOOW, ST, STW, STO, STOW, STOO, STOOW, SPT-3
46
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 1-15P PLUG, WITH CORD GRIP
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-08D
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SJ, SJO, SJOW, SJW#44 SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, SVTO, ST, STW, STO,
STOO, STOW, SPT-3
17/2 AWG (12A/125V): SJ, SJO, SJOW, SJW#44 SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, SVTO, ST, STW, STO,
STOO, STOOW, STOW, SPT-3
16/2 AWG (13A/125V): SJ, SJO, SJOW, SJW#44 SV, SVO, SVOW, SO, SOO,SOOW,
SOW, SJT, SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SVT, ST, STW, STO, STOO,
STOOW, STOW, SPT-3
14/2 AWG (15A/125V): SJ, SJO, SJOW, SJW#44 SO, SOO, SOOW, SOW, SJT, SJTW,
SJTO, SJTOO, SJTOW, SJTOOW, ST, STW, STO, STOO, STOOW, STOW, SPT-3
UC-08F
CONFIGURATION STANDARD: NEMA 1-15P PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SVT
17/2 AWG (12A/125V): SVT
CONFIGURATION STANDARD: NEMA 1-15P TILT PROOF PLUG, WITH CORD GRIP
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-08BT
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SVT, SJT
17/2 AWG (12A/125V): SVT, SJT
16/2 AWG (13A/125V): SVT, SJT
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C14 PLUG CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-009
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SVT SHIELDED, SJT, SJT SHIELDED, STO, SJTO,
SJTOW, SJTW, STOW
16/3 AWG (13A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/3 AWG (15A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
47
Plugs & Connectors
UC-09I
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C14 PLUG CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA), VDE (GERMANY),
CE (EUROPE), SAA (AUSTRALIA)
AMPERAGE: 15A (N. AMERICA), 10A (EUROPE, AUSTRALIA)
VOLTAGE: 250V
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SVT SHIELDED, SJT, SJT SHIELDED, STO, SJTO,
SJTOW, SJTW, STOW
16/3 AWG (13A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/3 AWG (15A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (10A/250V): H05VV-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C14 RIGHT ANGLE PLUG
CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-09A
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SVT SHIELDED, SJT, SJT SHIELDED, STO, SJTO,
SJTOW, SJTW, STOW
16/3 AWG (13A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/3 AWG (15A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C14 RIGHT ANGLE
PLUG CONNECTOR
APPROVALS: SAA (AUSTRALIA)
AMPERAGE: 10A
VOLTAGE: 250V
UC-09AI
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C14 RIGHT ANGLE PLUG
CONNECTOR, LOW PROFILE
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), IMQ (ITALY),
KEMA (NETHERLANDS), NEMKO (NORWAY), OVE (AUSTRIA),
SEMKO (SWEDEN), SEV (SWITZERLAND), VDE (GERMANY), CE (EUROPE)
AMPERAGE: 10A
VOLTAGE: 250V
UC-09BI
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (10A/250V): H05VV-F
48
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C18 PLUG CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA),
DEMKO (DENMARK), FIMKO (FINLAND), IMQ (ITALY), KEMA (NETHERLANDS),
NEMKO (NORWAY), OVE (AUSTRIA), SEMKO (SWEDEN), SEV (SWITZERLAND),
VDE (GERMANY), CE (EUROPE)
AMPERAGE: 15A (N. AMERICA), 10A (EUROPE, AUSTRALIA)
VOLTAGE: 250V
UC-09CI
Applicable Wire Type/Size:
18/2 AWG (10A/250V): SVT, SVT SHIELDED, SJT, SJT SHIELDED, STO, SJTO,
SJTOW, SJTW, STOW
16/2 AWG (13A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
14/2 AWG (15A/250V): SJT, SJTO, SJTOW, SJTW, SJT SHIELDED
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
UC-010
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C5 CONNECTOR
APPROVALS: PENDING
AMPERAGE: 2.5A
VOLTAGE: 250V
Applicable Wire Type/Size:
0.75mm2 (2.5A/250V): H03VV-F, H05VV-F
1.00mm2 (2.5A/250V): H05VV-F
CONFIGURATION STANDARD: NEMA 1-15P TOY PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-011
Applicable Wire Type/Size:
18/2 AWG (10A/125V): NISPT-1, SPT-2
16/2 AWG (13A/125V): SPT-2
CONFIGURATION STANDARD: NEMA 1-15P PLUG, SHROUDED
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-014
Applicable Wire Type/Size:
18/2 AWG (10A/125V):
SVT, STOO, STOOW, SJT#44 SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SJO, SJOW
16/2 AWG (13A/125V):
STOO, STOOW, SJT#44 SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SJO, SJOW
14/2 AWG (15A/125V):
STOO, STOOW, SJT#44 SJTW, SJTO, SJTOO, SJTOW, SJTOOW, SJO, SJOW
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
49
Plugs & Connectors
UC-018
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE HOSPITAL GRADE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/3 AWG SHIELDED/UNSHIELDED (10A/125V):
SVT, SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
16/3 AWG SHIELDED/UNSHIELDED (13A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
14/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
12/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJT, SJTW, SJTOW LOW LEAKAGE
UC-018A
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE HOSPITAL GRADE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/3 AWG SHIELDED/UNSHIELDED (10A/125V):
SVT, SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
16/3 AWG SHIELDED/UNSHIELDED (13A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
14/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
12/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJT, SJTW, SJTOW LOW LEAKAGE
UC-018AL
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE HOSPITAL GRADE
PLUG, WITH LAMP
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/3 AWG SHIELDED/UNSHIELDED (10A/125V):
SVT, SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
16/3 AWG SHIELDED/UNSHIELDED (13A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
14/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
12/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJT, SJTW, SJTOW LOW LEAKAGE
50
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
UC-018G
CONFIGURATION STANDARD: NEMA 5-15P HOSPITAL GRADE PLUG,
WITH CORD GRIP
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/3 AWG SHIELDED/UNSHIELDED (10A/125V):
SVT, SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
16/3 AWG SHIELDED/UNSHIELDED (13A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
14/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
12/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJT, SJTW, SJTOW LOW LEAKAGE
CONFIGURATION STANDARD: NEMA 5-15P HOSPITAL GRADE PLUG, WITH LAMP
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-018L
Applicable Wire Type/Size:
18/3 AWG SHIELDED/UNSHIELDED (10A/125V):
SVT, SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
16/3 AWG SHIELDED/UNSHIELDED (13A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
14/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJ, SJO, S, SO, SJOW, SOOW, SJT, SJT LOW LEAKAGE
12/3 AWG SHIELDED/UNSHIELDED (15A/125V):
SJT, SJTW, SJTOW LOW LEAKAGE
CONFIGURATION STANDARD: NEMA 1-15R CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-020
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SJT, SJTW, HPN
16/2 AWG (13A/125V):
SJT, SJTW, SJTO, SJTOW, SPT-2, SPT-3
16/2 AWG (15A/125V): HPN
14/2 AWG (15A/125V):
SJT, SJTW, SJTO, SJTOW, SPT-3
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
51
Plugs & Connectors
UC-021
CONFIGURATION STANDARD: NEMA 1-15R 3-WAY CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
Applicable Wire Type/Size:
16/2 AWG (13A/125V): SPT-2
CONFIGURATION STANDARD: NEMA 5-15R CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-022
Applicable Wire Type/Size:
18/3 AWG (10A/125V):
SJT, SJTW, SJTOW, ST, ST SHIELDED, STO, STOW, SJ, SJO, SJOW, SJOOW,
SJW, SO, SOO, SOOW, SOW
16/3 AWG (13A/125V):
SJT, SJT SHIELDED, SJTW, SJTO, SJTOW, ST, STO, STOW, SJ, SJO, SJOW,
SJOOW, SJW, SO, SOO, SOOW, SOW, SPT-2, SPT-3
14/3 AWG (15A/125V):
SJT, SJTW, SJTO, SJTOW, ST, STW, STOW, SPT-3, SJ, SJO, SJOW, SJOOW,
SJW, SO, SOO, SOW, SOOW
12/3 AWG (15A/125V):
ST, STW, STOW, SJ, SJO, SJOW, SJOOW, SJW, SO, SOO, SOW, SOOW
CONFIGURATION STANDARD: NEMA 5-15P/R “PIGGYBACK” PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-026
Applicable Wire Type/Size:
18/2, 18/3 AWG (10A/125V): SO, SOO, SOOW, SOW, SJ, SJO, SJOO,
SJOW, SJW, SV, SVO, SVOO, SJT, SJTW, SJTOO, SJTOW, SJTOOW, SVT
16/2, 16/3 AWG (13A/125V): SO, SOO, SOOW, SOW, SJ, SJO, SJOO,
SJOW, SJW, SV, SVO, SVOO, SJT, SJTW, SJTOO, SJTOW, SJTOOW, SVT
14/2, 14/3 AWG (15A/125V): SO, SOO, SOOW, SOW, SJ, SJO, SJOO,
SJOW, SJW, SJT, SJTW, SJTOO, SJTOW, SJTOOW
CONFIGURATION STANDARD: NEMA 5-15P/R “PIGGYBACK” PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-028
Applicable Wire Type/Size:
18/2, 18/3 AWG (10A/125V): SJT, SJTW, SJTOW, SJOW, SOW
16/2, 16/3 AWG (13A/125V): SJT, SJTW, SJTOW, SJOW, SOW
14/2, 14/3 AWG (15A/125V): SJT, SJTW, SJTOW, SJOW, SOW
12/2, 12/3 AWG (15A/125V): SJT, SJTW, SJTOW, SJOW, SOW
52
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
UC-032
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C20 PLUG CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 20A
VOLTAGE: 250V
Applicable Wire Type/Size:
14/3 AWG (18A/250V): SJT, SJT SHIELDED, ST
12/3 AWG (20A/250V): SJT, SJT SHIELDED, ST
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C20 CONNECTOR
APPROVALS: PENDING
AMPERAGE: 16A
VOLTAGE: 250V
UC-032I
Applicable Wire Type/Size:
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (16A/250V): H05VV-F
UC-032R
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C20 RIGHT ANGLE CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 20A
VOLTAGE: 250V
Applicable Wire Type/Size:
14/3 AWG (18A/250V): SJT, SJT SHIELDED, ST
12/3 AWG (20A/250V): SJT, SJT SHIELDED, ST
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C20 RIGHT ANGLE
CONNECTOR
APPROVALS: PENDING
AMPERAGE: 16A
VOLTAGE: 250V
UC-032RI
Applicable Wire Type/Size:
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (16A/250V): H05VV-F
UC-033
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C19 CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 20A
VOLTAGE: 250V
Applicable Wire Type/Size:
14/3 AWG (18A/250V): SJT, SJT SHIELDED, SJTO, ST, STO
12/3 AWG (20A/250V): SJT, SJT SHIELDED, SJTO, ST, STO
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
53
Plugs & Connectors
UC-033I
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C19 CONNECTOR
APPROVALS: PENDING
AMPERAGE: 16A
VOLTAGE: 250V
Applicable Wire Type/Size:
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (16A/250V): H05VV-F
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C19 RIGHT ANGLE
CONNECTOR
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 20A
VOLTAGE: 250V
UC-033R
Applicable Wire Type/Size:
14/3 AWG (18A/250V): SJT, SJT SHIELDED, SJTO, ST, STO
12/3 AWG (20A/250V): SJT, SJT SHIELDED, SJTO, ST, STO
CONFIGURATION STANDARD: EUROPEAN IEC 60320/C19 RIGHT ANGLE
CONNECTOR
APPROVALS: PENDING
AMPERAGE: 16A
VOLTAGE: 250V
UC-033RI
Applicable Wire Type/Size:
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (16A/250V): H05VV-F
UC-034
CONFIGURATION STANDARD: 2-PIN APPLIANCE PLUG, .109" DIA
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 10A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SVT
UC-035
CONFIGURATION STANDARD: 2-PIN APPLIANCE CONNECTOR, .109" DIA
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 10A
VOLTAGE: 125V
Applicable Wire Type/Size:
18/2 AWG (10A/125V): SVT
54
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: 2-PIN PHENOLIC APPLIANCE CONNECTOR, .156" DIA
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A (125V), 10A (250V)
VOLTAGE: 125V/250V
UC-040
Applicable Wire Type/Size:
18/2 AWG (10A/125V): HPN
16/2 AWG (15A/125V, 10A/250V): HPN
CONFIGURATION STANDARD: 2-PIN PHENOLIC APPLIANCE CONNECTOR,
.156" DIA.
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A (125V), 10A (250V)
VOLTAGE: 125V/250V
UC-041
Applicable Wire Type/Size:
18/2 AWG (10A/125V): HPN
16/2 AWG (15A/125V, 10A/250V): HPN
UC-051
CONFIGURATION STANDARD: CHINESE GB 1002 PLUG
APPROVALS: CCC (CHINA)
AMPERAGE: 10A
VOLTAGE: 250V
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VVH2-F, H03VV-F, RVV 300/300V
1.00mm2 (10A/250V): H05VVH2-F, H05VV-F, RVV 300/500V
UC-052
CONFIGURATION STANDARD: CHINESE GB 1002 CONNECTOR
APPROVALS: CCC (CHINA)
AMPERAGE: 10A
VOLTAGE: 250V
Applicable Wire Type/Size:
1.00mm2 (10A/250V): H05VV-F, RVV 300/500V
UC-053
CONFIGURATION STANDARD: CHINESE GB 1002 PLUG
APPROVALS: CCC (CHINA)
AMPERAGE: 10A
VOLTAGE: 250V
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F, RVV 300/500V
1.00mm2 (10A/250V): H05VV-F, RVV 300/500V
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
55
Plugs & Connectors
UC-054
CONFIGURATION STANDARD: CHINESE GB 1002 RIGHT ANGLE PLUG
APPROVALS: CCC (CHINA)
AMPERAGE: 10A
VOLTAGE: 250V
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F, RVV 300/500V
1.00mm2 (10A/250V): H05VV-F, RVV 300/500V
UC-055
CONFIGURATION STANDARD: CHINESE GB 1002 PLUG
APPROVALS: CCC (CHINA)
AMPERAGE: 16A
VOLTAGE: 250V
Applicable Wire Type/Size:
1.50mm2 (16A/250V): H05VV-F, RVV 300/500V
UC-056
CONFIGURATION STANDARD: CHNIESE GB 1002 RIGHT ANGLE PLUG
APPROVALS: CCC (CHINA)
AMPERAGE: 16A
VOLTAGE: 250V
Applicable Wire Type/Size:
1.50mm2 (16A/250V): H05VV-F, RVV 300/500V
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE PLUG, WITH VENT TUBE
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-071
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO, SJTOW, ST, STW, STO, STOW, SPT-1,
SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO,STOW, SPT-2, SPT-3
14/3 AWG (15A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO,STOW, SPT-3
12/3 AWG (15A/125V): SJT, SJTW, SJTO, SJTOW, ST, STW, STO,STOW, SPT-3
56
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-071N
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT1, SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT-2,
SPT-3
14/3 AWG (15A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT-3
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-071S
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW,
SPT-1, SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT-2,
SPT-3
14/3 AWG (15A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT-3
CONFIGURATION STANDARD: NEMA 5-15P RIIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-071X
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW,
SPT-1, SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT-2,
SPT-3
14/3 AWG (15A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT-3
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE PLUG, 45 DEGREE
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-071XA
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW,
SPT-1, SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-2,
SPT-3
14/3 AWG (15A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-3
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
57
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-071Y
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW,
SPT-1, SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT-2,
SPT-3
14/3 AWG (15A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO,STOW, SPT-3
CONFIGURATION STANDARD: NEMA 5-15P RIGHT ANGLE PLUG, 45 DEGREE
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 125V
UC-071YA
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW,
SPT-1, SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-2,
SPT-3
14/3 AWG (15A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-3
CONFIGURATION STANDARD: NEMA 5-20P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 20A
VOLTAGE: 125V
UC-072
Applicable Wire Type/Size:
18/3 AWG (10A/125V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW,
SPT-2, SPT-3
16/3 AWG (13A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-2,
SPT-3
14/3 AWG (18A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-3
12/3 AWG (20A/125V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-3
CONFIGURATION STANDARD: NEMA 6-15P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 15A
VOLTAGE: 250V
UC-073
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW,
SPT-2, SPT-3
16/3 AWG (13A/250V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-2,
SPT-3
14/3 AWG (18A/250V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-3
12/3 AWG (20A/250V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-3
58
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: NEMA 6-20P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA), CSA (CANADA)
AMPERAGE: 20A
VOLTAGE: 250V
UC-074
Applicable Wire Type/Size:
18/3 AWG (10A/250V): SVT, SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW,
SPT-2, SPT-3
16/3 AWG (13A/250V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-2,
SPT-3
14/3 AWG (18A/250V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-3
12/3 AWG (20A/250V): SJT, SJTW, SJTO#44 SJTOW, ST, STW, STO, STOW, SPT-3
UC-077
CONFIGURATION STANDARD: NEMA 6-30P RIGHT ANGLE PLUG
APPROVALS: UL (AMERICA), CUL (CANADA)
AMPERAGE: 30A
VOLTAGE: 250V
Applicable Wire Type/Size:
10/3 AWG (30A/250V): S, SO, SOO, SJT#44 ST, STO, STOO, SE,
SW, SOW, SOOW, STW, STOW, STOOW, SEW
CONFIGURATION STANDARD: DC OUTPUT PLUG, FEMALE, DIA. 3.0MM
APPROVALS: (PENDING)
AMPERAGE: LOW CURRENT
VOLTAGE: LOW VOLTAGE
UC-701
Applicable Wire Type/Size:
22/2 AWG: XTW
20/2 AWG: XTW
18/2 AWG: SPT-1
CONFIGURATION STANDARD: EUROPEAN CEE 7/16 2-PIN PLUG
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), IMQ (ITALY),
KEMA (NETHERLANDS), NEMKO (NORWAY), OVE (AUSTRIA), SEMKO (SWEDEN),
SEV (SWITZERLAND), VDE (GERMANY)
AMPERAGE: 2.5A
VOLTAGE: 250V
UC-811
Applicable Wire Type/Size:
0.75mm2 (2.5A/250V): H03VVH2-F, H05VVH2-F, H03VV-F, H05VV-F
1.00mm2 (2.5A/250V): H05VV-F
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
59
Plugs & Connectors
CONFIGURATION STANDARD: EUROPEAN CEE 7/17 2-PIN “EURO” PLUG
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), KEMA (NETHERLANDS),
NEMKO (NORWAY), OVE (AUSTRIA), SEMKO (SWEDEN), VDE (GERMANY)
AMPERAGE: 16A
VOLTAGE: 250V
UC-812
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VVH2-F, H05VVH2-F, H03VV-F, H05VV-F, H05RR-F
1.00mm2 (10A/250V): H05VV-F, H05RR-F, H07RN-F
1.50mm2 (16A/250V): H05VV-F, H07RN-F
CONFIGURATION STANDARD: EUROPEAN CEE 7/7 GROUNDING “SCHUKO” PLUG
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), KEMA (NETHERLANDS),
NEMKO (NORWAY), OVE (AUSTRIA), SEMKO (SWEDEN), VDE (GERMANY)
AMPERAGE: 16A
VOLTAGE: 250V
UC-813
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VV-F, H05VV-F, H05RR-F, H05RN-F
1.00mm2 (10A/250V): H05VV-F, H05RR-F, H05RN-F, H07RN-F
1.50mm2 (16A/250V): H05VV-F, H05RR-F, H07RN-F
CONFIGURATION STANDARD: EUROPEAN CEE 7/7 RIGHT ANGLE GROUNDING
“SCHUKO” PLUG
APPROVALS: DEMKO (DENMARK), FIMKO (FINLAND), KEMA (NETHERLANDS),
NEMKO (NORWAY), OVE (AUSTRIA), SEMKO (SWEDEN), VDE (GERMANY)
AMPERAGE: 16A
VOLTAGE: 250V
UC-814
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VV-F, H05VV-F, H05RR-F, H05RN-F
1.00mm2 (10A/250V): H05VV-F, H05RR-F, H05RN-F
1.50mm2 (16A/250V): H05VV-F, H05RR-F, H07RN-F
CONFIGURATION STANDARD: AUSTRALIAN AS 3112 PLUG
APPROVALS: SAA (AUSTRALIA)
AMPERAGE: 10A
VOLTAGE: 250V
UC-821
Applicable Wire Type/Size:
0.75mm2 (7.5A/250V): H03VVH2-F, H03VV-F, H05VVH2-F, H05VV-F
1.00mm2 (10A/125V): H05VV-F, H07RN-F
60
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: AUSTRALIAN AS 3112 PLUG
APPROVALS: SAA (AUSTRALIA)
AMPERAGE: 10A
VOLTAGE: 250V
UC-822
Applicable Wire Type/Size:
0.75mm2 (7.5A/250V): H03VVH2-F, H03VV-F, H05VVH2-F, H05VV-F, H05RR-F,
H05RN-F
1.00mm2 (10A/250V): H05VV-F, H05RR-F, H05RN-F, H07RN-F
CONFIGURATION STANDARD: AUSTRALIAN AS 3112 RIGHT ANGLE PLUG
APPROVALS: SAA (AUSTRALIA)
AMPERAGE: 10A
VOLTAGE: 250V
UC-823
Applicable Wire Type/Size:
0.75mm2 (7.5A/250V): H03VVH2-F, H03VV-F, H05VVH2-F, H05VV-F, H05RR-F,
H05RN-F
1.00mm2 (10A/250V): H05VV-F, H05RR-F, H05RN-F, H07RN-F
UC-824
CONFIGURATION STANDARD: AUSTRALIAN AS 3112 PLUG
APPROVALS: SAA (AUSTRALIA)
AMPERAGE: 15A
VOLTAGE: 250V
Applicable Wire Type/Size:
1.00mm2 (10A/250V): H05VV-F, H05RR-F, H05RN-F, H07RN-F
1.50mm2 (15A/250V): H05VV-F, H05RR-F, H07RN-F
CONFIGURATION STANDARD: JAPANESE JIS C8303 PLUG
APPROVALS: PSE DENAN (JAPAN)
AMPERAGE: 15A
VOLTAGE: 125V
UC-830
Applicable Wire Type/Size:
0.75mm2 (7A/125V): VFF, HVFF, VCTF, HVCTF, VCTFK, HVCTFK
1.25mm2 (12A/125V): VFF, HVFF, VCTF, HVCTF, VCTFK, HVCTFK
2.00mm2 (15A/125V): VFF, HVFF, VCTF, HVCTF, VCTFK, HVCTFK
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
61
Plugs & Connectors
CONFIGURATION STANDARD: JAPANESE JIS C8303 CONNECTOR
APPROVALS: PSE DENAN (JAPAN)
AMPERAGE: 15A
VOLTAGE: 125V
UC-831
Applicable Wire Type/Size:
0.75mm2 (7A/125V): VFF, HVFF, VCTF, HVCTF, VCTFK, HVCTFK
1.25mm2 (12A/125V): VFF, HVFF, VCTF, HVCTF, VCTFK, HVCTFK
2.00mm2 (15A/125V): VFF, HVFF, VCTF, HVCTF, VCTFK, HVCTFK
CONFIGURATION STANDARD: JAPANESE JIS C8303 PLUG
APPROVALS: PSE DENAN (JAPAN)
AMPERAGE: 15A
VOLTAGE: 125V
UC-832
Applicable Wire Type/Size:
0.75mm2 (7A/125V): VCTF, HVCTF, VCTFK, HVCTFK
1.25mm2 (12A/125V): VCTF, HVCTF, VCTFK, HVCTFK
2.00mm2 (15A/125V): VCTF, HVCTF, VCTFK, HVCTFK
CONFIGURATION STANDARD: JAPANESE JIS C8303 PLUG, WITH DRAIN WIRE
APPROVALS: PSE DENAN (JAPAN)
AMPERAGE: 15A
VOLTAGE: 125V
UC-834
Applicable Wire Type/Size:
0.75mm2 (7A/125V): VCTF, HVCTF, VCTFK, HVCTFK
1.25mm2 (12A/125V): VCTF, HVCTF, VCTFK, HVCTFK
2.00mm2 (15A/125V): VCTF, HVCTF, VCTFK, HVCTFK
CONFIGURATION STANDARD: JAPANESE IEC 60320/C13 CONNECTOR
APPROVALS: PSE DENAN (JAPAN)
AMPERAGE: 15A
VOLTAGE: 125V
UC-837
Applicable Wire Type/Size:
0.75mm2 (7A/125V): VCTF, HVCTF
1.25mm2 (12A/125V): VCTF, HVCTF
2.00mm2 (15A/125V): VCTF, HVCTF
62
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Plugs & Connectors
CONFIGURATION STANDARD: JAPANESE IEC 60320/C13 RIGHT ANGLE
CONNECTOR
APPROVALS: PSE DENAN (JAPAN)
AMPERAGE: 15A
VOLTAGE: 125V
UC-838
Applicable Wire Type/Size:
0.75mm2 (7A/125V): VCTF, HVCTF
1.25mm2 (12A/125V): VCTF, HVCTF
CONFIGURATION STANDARD: SWISS SEV 1011 TYPE 11 PLUG
APPROVALS: SEV (SWITZERLAND)
AMPERAGE: 10A
VOLTAGE: 250V
UC-840
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VV-F, H03VVH2-F, H05VV-F, H05VVH2-F
1.00mm2 (10A/250V): H05VV-F
CONFIGURATION STANDARD: SWISS SEV 1011 TYPE 12 PLUG
APPROVALS: SEV (SWITZERLAND)
AMPERAGE: 10A
VOLTAGE: 250V
UC-841
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VV-F, H05VV-F
1.00mm2 (10A/250V): H05VV-F
UC-861
CONFIGURATION STANDARD: ITALIAN CEI 23-16-VII PLUG
APPROVALS: PENDING
AMPERAGE: 10A
VOLTAGE: 250V
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VV-F, H05VV-F, H05RR-F, H03RT-F
1.00mm2 (10A/250V): H05VV-F, H05RR-F, H03RT-F, H05RN-F, H07RN-F
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
63
Plugs & Connectors
CONFIGURATION STANDARD: BS 546 RIGHT ANGLE PLUG
APPROVALS: PENDING
AMPERAGE: 15A
VOLTAGE: 250V
UC-871
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VV-F, H03RT-F, H05VV-F
1.00mm2 (10A/250V): H03RT-F, H05VV-F
1.50mm2 (15A/250V): H03RT-F, H05VV-F
CONFIGURATION STANDARD: BS 546 PLUG
APPROVALS: PENDING
AMPERAGE: 15A
VOLTAGE: 250V
UC-872
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H03VV-F, H05VV-F
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (15A/250V): H05VV-F
CONFIGURATION STANDARD: DANISH AFSNIT 107-2-D1 PLUG
APPROVALS: DEMKO (DENMARK)
AMPERAGE: 10A
VOLTAGE: 250V
UC-881
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/125V): H05VV-F
UC-882
CONFIGURATION STANDARD: DANISH AFSNIT 107-2-D1 PLUG
APPROVALS: DEMKO (DENMARK)
AMPERAGE: 10A
VOLTAGE: 250V
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/125V): H05VV-F
CONFIGURATION STANDARD: ISRAEL SI 32 3-PIN PLUG
APPROVALS: PENDING
AMPERAGE: 16A
VOLTAGE: 250V
UC-892
Applicable Wire Type/Size:
0.75mm2 (6A/250V): H05VV-F
1.00mm2 (10A/250V): H05VV-F
1.50mm2 (16A/250V): H05VV-F
64
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Wire Reference Guide
North American Wire Types
Type: SVT
NUMBER
COND
3
AWG
18
Foil Shield, Thermoplastic, 300V
STRANDING
41x34
Type: SJT
NUMBER
COND
3
3
3
3
AWG
18
16
14
12
3
3
3
3
AWG
18
16
14
12
INSULATION
THICKNESS
INCHES
0.015
JACKET
THICKNESS
INCHES
0.030
NOMINAL**
O.D.
INCHES
TEMP
0.248
60ºC/105ºC
COLORS
Black, Gray, or Custom
Foil Shield, Thermoplastic, 300V
STRANDING
41x34
65x34
41x30
65x30
Type: SJT
NUMBER
COND
3-Conductor, Shielded
INSULATION
THICKNESS
INCHES
0.030
0.030
0.030
0.030
JACKET
THICKNESS
INCHES
0.030
0.030
0.030
0.045
NOMINAL**
O.D.
INCHES
TEMP
0.343
0.360
0.390
0.437
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
COLORS
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
Foil & Braid Shield, Thermoplastic, 300V
STRANDING
41x34
65x34
41x30
65x30
INSULATION
THICKNESS
INCHES
0.030
0.030
0.030
0.030
JACKET
THICKNESS
INCHES
0.030
0.030
0.030
0.045
NOMINAL**
O.D.
INCHES
TEMP
0.390
0.412
0.443
0.484
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
COLORS
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
North American and CEE color codes available.
** Reference O.D.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
65
Wire Reference Guide
North American Wire Types
Type: SVT*
NUMBER
COND
3
AWG
18
3-Conductor, Un-Shielded
Thermoplastic, 300V
STRANDING
41x34
INSULATION
THICKNESS
INCHES
0.015
*Type: SVTO/SVT oil-resistant also available.
Type: SJT*
NUMBER
COND
3
3
3
3
AWG
18
16
14
12
JACKET
THICKNESS
INCHES
0.030
NOMINAL**
O.D.
INCHES
TEMP
0.255
STRANDING
41x34
26x30
41x30
65x30
Type: ST*
3
3
3
3
AWG
18
16
14
12
COLORS
Black, Gray, or Custom
Thermoplastic, 300V
INSULATION
THICKNESS
INCHES
0.030
0.030
0.030
0.030
JACKET
THICKNESS
INCHES
0.030
0.030
0.030
0.045
NOMINAL**
O.D.
INCHES
TEMP
0.307
0.334
0.375
0.429
*Type SJTO/SJT oil-resistant also available. Type SJTW available for outdoor use.
NUMBER
COND
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
COLORS
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
Thermoplastic, 600V
STRANDING
16x30
26x30
41x30
65x30
INSULATION
THICKNESS
INCHES
0.030
0.030
0.045
0.045
JACKET
THICKNESS
INCHES
0.060
0.060
0.080
0.095
NOMINAL**
O.D.
INCHES
TEMP
0.370
0.405
0.531
0.600
*Type: STO/ST oil-resistant also available. Type: STW available for outdoor use.
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
COLORS
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
** Reference O.D.
66
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Wire Reference Guide
North American Wire Types
Type: SPT-1
NUMBER
COND
3
AWG
18
Thermoplastic, 300V
STRANDING
41x34
Type: SPT-2
NUMBER
COND
3
3
AWG
18
16
3
3
3
3
AWG
18
16
14
12
STRANDING
41x34
65x34
3
3
AWG
18
16
STRANDING
41x34
65x34
41x30
65x30
3
3
AWG
0.118/.315
TEMP
COLORS
TEMP
COLORS
60ºC/105ºC
Black, Brown, White, or Custom
INSULATION
THICKNESS
INCHES
0.045
0.045
NOMINAL**
O.D.
INCHES
0.142/.339
0.154/.382
60ºC/105ºC
60ºC/105ºC
Black, Brown, White, or Custom
Black, Brown, White, or Custom
INSULATION
THICKNESS
INCHES
NOMINAL**
O.D.
INCHES
0.060
0.060
0.080
0.095
0.173/.394
0.181/.445
0.240/.559
0.287/.591
TEMP
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
60ºC/105ºC
COLORS
Black, Brown, Gray, or Custom
Black, Brown, Gray, or Custom
Black, Brown, Gray, or Custom
Black, Brown, Gray, or Custom
Thermoset, 300V
STRANDING
41x34
65x34
Type: SRDT
NUMBER
COND
0.015
NOMINAL**
O.D.
INCHES
Thermoplastic, 600V
Type: HPN
NUMBER
COND
INSULATION
THICKNESS
INCHES
Thermoplastic, 300V
Type: SPT-3
NUMBER
COND
3-Conductor, Parallel
INSULATION
THICKNESS
INCHES
0.045
0.045
NOMINAL**
O.D.
INCHES
0.142/.339
0.161/.366
TEMP
COLORS
90ºC/105ºC
90ºC/105ºC
Black, Brown, or Custom
Black, Brown, or Custom
TEMP
COLORS
Thermoplastic, 300V
STRANDING
2/6+1/8 266/168x30
3/10
104x30
INSULATION
THICKNESS
INCHES
0.10
0.10
NOMINAL**
O.D.
INCHES
0.453/1.028
0.374/.795
60ºC/105ºC
60ºC/105ºC
Black, Gray, or Custom
Black, Gray, or Custom
Ground wire insulation is green.
**Reference O.D.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
67
Wire Reference Guide
North American Wire Types
Type: SVT*
NUMBER
COND
2
2-Conductor, Jacketed
2-Conductor, Thermoplastic, 300V
AWG
STRANDING
18
41x34
INSULATION
THICKNESS
INCHES
0.015
*Type: SVTO/SVT oil-resistant also available.
Type: SJT*
NUMBER
COND
2
2
AWG
STRANDING
18
16
41x34
26x30
Type: SJTO/SJT*
2
2
AWG
18
16
0.030
INSULATION
THICKNESS
INCHES
0.030
0.030
JACKET
THICKNESS
INCHES
0.030
0.030
STRANDING
41x34
26x30
Type: ST*
2
2
AWG
18
16
NUMBER
COND
2
2
AWG
18
16
COLORS
60ºC/105ºC
Black, Gray, or Custom
NOMINAL**
O.D.
INCHES
TEMP
0.280
0.320
COLORS
60ºC/105ºC
60ºC/105ºC
Black, Gray, or Custom
Black, Gray, or Custom
INSULATION
THICKNESS
INCHES
0.030
0.030
JACKET
THICKNESS
INCHES
0.030
0.030
NOMINAL**
O.D.
INCHES
TEMP
0.280
0.320
COLORS
60ºC/105ºC
60ºC/105ºC
Black, or Custom
Black, or Custom
2-Conductor, Extra Hard Service, Thermoplastic, 600V
STRANDING
16x30
26x30
*Type: STW available for outdoor use.
Type: STO*
0.248
2-Conductor, Oil Resistant, Thermoplastic, 300V
*Type: SJTOW/SJTW oil-resistant also available for outdoor use.
NUMBER
COND
NOMINAL**
O.D.
INCHES
TEMP
2-Conductor, Thermoplastic, 300V
*Type SJTW available for outdoor use.
NUMBER
COND
JACKET
THICKNESS
INCHES
INSULATION
THICKNESS
INCHES
0.030
0.030
JACKET
THICKNESS
INCHES
0.060
0.060
NOMINAL**
O.D.
INCHES
TEMP
0.346
0.374
60ºC/105ºC
60ºC/105ºC
COLORS
Black, or Custom
Black, or Custom
2-Conductor, Extra Hard Service, Oil Resistant, Thermoplastic, 600V
STRANDING
16x30
26x30
*Type STOW available for outdoor use.
INSULATION
THICKNESS
INCHES
0.030
0.030
JACKET
THICKNESS
INCHES
0.060
0.060
NOMINAL**
O.D.
INCHES
TEMP
0.346
0.374
60ºC/105ºC
60ºC/105ºC
COLORS
Black, or Custom
Black, or Custom
North American and CEE color codes available.
**Reference O.D.
68
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Wire Reference Guide
North American Wire Types
Type: SPT-1
NUMBER
COND
2
AWG
18
Thermoplastic, 300V
STRANDING
41x34
Type: SPT-2
NUMBER
COND
2
2
AWG
18
16
2
2
AWG
18
16
STRANDING
41x34
65x34
2
2
AWG
18
16
STRANDING
16x30
26x30
2
AWG
20
STRANDING
41x34
65x34
2
AWG
27
TEMP
COLORS
60ºC/105ºC
Black, Brown, White, Clear Gold
or Custom
INSULATION
THICKNESS
INCHES
0.045
0.045
NOMINAL**
O.D.
INCHES
0.139/.271
0.152/.289
TEMP
COLORS
TEMP
COLORS
TEMP
COLORS
60ºC/105ºC
60ºC/105ºC
Black, Brown, White, or Custom
Black, Brown, White, or Custom
INSULATION
THICKNESS
INCHES
0.060
0.060
NOMINAL**
O.D.
INCHES
0.173/.346
0.190/.364
60ºC/105ºC
60ºC/105ºC
Black, Brown, Gray, or Custom
Black, Brown, Gray, or Custom
INSULATION
THICKNESS
INCHES
0.045
0.045
NOMINAL**
O.D.
INCHES
0.138/.280
0.150/.307
90ºC/105ºC
90ºC/105ºC
Black, Brown, Gray or Custom
Black, Brown, Gray or Custom
Thermoplastic Insulation, 125V
STRANDING
27x34
Type: TPT
NUMBER
COND
0.108/.210
Thermoset Insulation, 300V
Type: XT/PXT
NUMBER
COND
0.030
NOMINAL**
O.D.
INCHES
Thermoplastic Insulation, 600V
Type: HPN
NUMBER
COND
INSULATION
THICKNESS
INCHES
Thermoplastic Insulation, 300V
Type: SPT-3
NUMBER
COND
2-Conductor, Parallel
INSULATION
THICKNESS
INCHES
0.030
NOMINAL**
O.D.
INCHES
0.100/0.193
TEMP
60ºC/105ºC
COLORS
Black, or Custom
Thermoplastic Insulation, Tinsel Wire, 250V
STRANDING
*15/T/250
INSULATION
THICKNESS
INCHES
0.030
NOMINAL**
O.D.
INCHES
0.110/0.205
TEMP
60ºC
*T-250: Nylon thread is wrapped by flattened copper (0.01” thick x 0.025” wide)
COLORS
Black, or Custom
**Reference O.D.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
69
Wire Reference Guide
International Wire Types 3-Conductor, Jacketed
Type: H03VV-F
NUMBER
COND
3
AWG
0.75mm²
Thermoplastic, 300V
STRANDING
24/0.21
Type: H05VV-F
NUMBER
COND
3
3
3
AWG
0.75mm²
1.00mm²
1.50mm²
3
3
3
AWG
0.75mm²
1.25mm²
2.00mm²
STRANDING
24/0.21
32/0.21
30/0.26
3
3
3
AWG
0.75mm²
1.25mm²
2.00mm²
NOMINAL**
O.D.
mm
TEMP
0.60
5.800
70ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, Gray, or Custom
INSULATION
THICKNESS
mm
0.60
0.60
0.70
0.80
0.80
0.90
6.70
7.00
8.50
70ºC
70ºC
70ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, Gray, or Custom
Black, Gray, or Custom
Black, Gray, or Custom
Thermoplastic, 300V
STRANDING
30/0.18
50/0.18
37/0.263
Type: HVCTF
NUMBER
COND
0.50
JACKET
THICKNESS
mm
Thermoplastic, 500V
Type: VCTF
NUMBER
COND
INSULATION
THICKNESS
mm
INSULATION
THICKNESS
mm
0.60
0.60
0.60
1.00
1.00
1.00
7.00
7.80
8.50
60ºC
60ºC
60ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, or Custom
Black, or Custom
Black, or Custom
Thermoplastic, 300V
STRANDING
30/0.18
50/0.18
37/0.263
INSULATION
THICKNESS
mm
0.60
0.60
0.60
1.00
1.00
1.00
7.00
7.80
8.50
75ºC
75ºC
75ºC
COLORS
Black, or Custom
Black, or Custom
Black or Custom
**Reference O.D.
70
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Wire Reference Guide
International Wire Types
Type: SAA
NUMBER
COND
3
Light Duty, Thermoplastic, 250V
AWG
0.75mm²
STRANDING
24/0.21
Type: H03VV-F
NUMBER
COND
3
3
AWG
0.75mm²
1.00mm²
2
AWG
0.75mm²
STRANDING
24/0.21
32/0.21
2
AWG
0.75mm²
STRANDING
24/0.21
2
2
AWG
0.75mm²
1.00mm²
NOMINAL**
O.D.
mm
TEMP
0.60
6.20
75ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, or Custom
INSULATION
THICKNESS
mm
0.60
0.60
0.80
0.80
6.80
7.10
75ºC
75ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, Gray, or Custom
Black, Gray or Custom
INSULATION
THICKNESS
mm
0.50
0.60
5.50
70ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, or Custom
Thermoplastic, 300V
STRANDING
24/0.21
Type: H05VV-F
NUMBER
COND
0.50
JACKET
THICKNESS
mm
Thermoplastic, 300V
Type: H03VVH2-F
NUMBER
COND
INSULATION
THICKNESS
mm
Thermoplastic, 300V
Type: H03VV-F
NUMBER
COND
3- & 2-Conductor, Jacketed
INSULATION
THICKNESS
mm
0.50
0.60
3.4/5.5
70ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, or Custom
Thermoplastic, 500V
STRANDING
24/0.21
32/0.21
INSULATION
THICKNESS
mm
0.60
0.60
0.80
0.80
6.30
6.70
70ºC
70ºC
COLORS
Black, Gray, or Custom
Black, Gray or Custom
**Reference O.D.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
71
Wire Reference Guide
International Wire Types
Type: H05VVH2-F
NUMBER
COND
2
AWG
0.75mm²
Thermoplastic, 300V
STRANDING
24/0.21
Type: VCTF
NUMBER
COND
2
2
2
AWG
0.75mm²
1.25mm²
2.00mm²
2
2
2
AWG
0.75mm²
1.25mm²
2.00mm²
STRANDING
30/0.18
50/0.18
37/0.26
2
2
2
AWG
0.75mm²
1.25mm²
2.00mm²
0.60
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
0.80
4.0/6.3
70ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, or Custom
INSULATION
THICKNESS
mm
0.60
0.60
0.60
1.00
1.00
1.00
6.60
7.40
8.40
60ºC
60ºC
60ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, or Custom
Black, or Custom
Black, or Custom
Thermoplastic, 300V
STRANDING
30/0.18
50/0.18
37/0.26
Type: VCTFK
NUMBER
COND
INSULATION
THICKNESS
mm
Thermoplastic, 300V
Type: HVCTF
NUMBER
COND
2-Conductor, Jacketed
INSULATION
THICKNESS
mm
0.60
0.60
0.60
1.00
1.00
1.00
6.60
7.40
8.40
75ºC
75ºC
75ºC
JACKET
THICKNESS
mm
NOMINAL**
O.D.
mm
TEMP
COLORS
Black, or Custom
Black, or Custom
Black, or Custom
Thermoplastic, 300V
STRANDING
30/0.18
50/0.18
37/0.26
INSULATION
THICKNESS
mm
0.60
0.60
0.60
1.00
1.00
1.00
4.3/6.6
4.7/7.4
5.0/8.0
60ºC
60ºC
60ºC
COLORS
Black, or Custom
Black, or Custom
Black, or Custom
**Reference O.D.
72
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Wire Reference Guide
International Wire Types
Type: HVCTFK
NUMBER
COND
AWG
2
2
2
0.75mm²
1.25mm²
2.00mm²
Thermoplastic, 300V
STRANDING
30/0.18
50/0.18
37/0.26
Type: SAA
NUMBER
COND
0.75mm²
0.75mm²
STRANDING
24/0.21
24/0.21
Type: SAA
NUMBER
COND
0.75mm²
0.75mm²
2.00mm²
STRANDING
24/0.21
24/0.21
32/0.21
Type: VFF
NUMBER
COND
2
2
2
2
2
2
2
0.60
0.60
0.60
NOMINAL**
O.D.
mm
TEMP
4.3/6.6
4.7/7.4
5.0/8.0
COLORS
75ºC
75ºC
75ºC
Black, or Custom
Black, or Custom
Black, or Custom
INSULATION
THICKNESS
mm
0.50
0.50
JACKET
THICKNESS
mm
0.60
0.60
NOMINAL**
O.D.
mm
TEMP
3.7/5.8
5.5
COLORS
75ºC
75ºC
Black, or Custom
Black, or Custom
AWG
0.50mm²
0.75mm²
1.25mm²
2.00mm²
AWG
0.75mm²
1.25mm²
2.00mm²
INSULATION
THICKNESS
mm
0.60
0.60
0.60
JACKET
THICKNESS
mm
0.80
0.80
0.80
NOMINAL**
O.D.
mm
TEMP
4.3/6.6
6.60
7.00
COLORS
75ºC
75ºC
75ºC
Black, or Custom
Black, or Custom
Black, or Custom
Thermoplastic, 300V
STRANDING
20/0.18
30/0.18
50/0.18
37/0.26
Type: HVFF
NUMBER
COND
0.60
0.60
0.60
JACKET
THICKNESS
mm
Ordinary Duty, Thermoplastic, 250V
AWG
2
2
2
INSULATION
THICKNESS
mm
Light Duty, Thermoplastic, 250V
AWG
2
2
2-Conductor, Jacketed & Parallel
INSULATION
THICKNESS
INCHES
0.80
0.80
0.80
0.80
NOMINAL**
O.D.
INCHES
2.5/5.0
2.7/5.4
3.1/.62
3.4/6.8
TEMP
60ºC
60ºC
60ºC
60ºC
COLORS
Black,
Black,
Black,
Black,
or
or
or
or
Custom
Custom
Custom
Custom
Thermoplastic, 300V
STRANDING
30/0.18
50/0.18
37/0.26
INSULATION
THICKNESS
INCHES
0.80
0.80
0.80
NOMINAL**
O.D.
INCHES
2.7/5.5
3.2/6.3
3.5/6.9
TEMP
75ºC
75ºC
75ºC
COLORS
Black, or Custom
Black, or Custom
Black, or Custom
**Reference O.D.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
73
Molded Strain Reliefs
Unit: mm
Strain Reliefs & Grommets
All Power Cords for appliances and tools must be attached so that:
*Pull force on the cord does not permit stress on the terminations.
*The chance of mechanical damage to the cord jacket and insulation is minimal.
*The flex life of the cord is not affected.
End product standards at UL and CSA often require a 35lb pull for one minute to be applied to the cord at the attachment
point to test for the strain-relief on the terminations. The design of the product and internal-wiring may suggest that it is
most efficient to use a custom molded component on the cord.
End product designers must consider all of the factors above to develop the correct part to pass all tests.
Strain Relief:
Necessary to restrict movement of the internal conductors of the cord so that stress is not applied to the terminations.
Internal clamps, posts and pressure points are frequently used.
Grommets:
Provide protection from damage by sharp edges or continuous movement.
Flex Relief:
Often required where the cord is frequently flexed by use of the appliance or tool. A good design prevents sharp bends in
the conductors that will fail due to metal fatigue of the copper strands.
Unicable will work with your designs or help develop new ones for your needs. We
can perform flex and strain-relief testing and provide you with results to optimize the
application. The following examples are a few of the potential solutions for your
consideration. Customized tooling is quick and inexpensive.
74
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Molded Strain Reliefs
Unit: mm
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
75
Molded Strain Reliefs
Unit: mm
76
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Molded Strain Reliefs
Unit: mm
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
77
Molded Strain Reliefs
Unit: mm
78
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
How to Specify Power Supply Cords
The Critical Parts of a Power Supply Cord
1. Plug
See our Plugs and Receptacles (pages 31-64) to identify correct configuration and rating to be specified.
2. Cord
See Wire Types (pages 65-73) to identify correct wire type to be specified. Include type, color, AWG, number of
conductors, temperature, and overall length, measuring from the face of the plug to the furthest end.
3. End Finishing
For detachable power supply cords, see our Plugs and Connectors (pages 31-64) to identify the correct configuration and
rating to be specified for this end.
For non-detachable power supply cords, choose from one of the following end treatments:
Outer Jacket
Blunt cut
Remove Outer Jacket
Parallel Cord
Blunt cut
Split Leads
Strip & Twist
ROJ & Strip
ROJ/Stagger
Split/Stagger
Strip, Twist & Tin (Specify any max
tinning OD required.)
End Treatment
Tinned Tips (Specify any max tinning OD req.)
Attach Terminal (Specify terminal req.)
Strip & Retain
Note any special requirements, such as custom molded strain reliefs, etc. A selection of standard strain reliefs are on
pages 75-78.
4. Standard Packaging
Is often required where the cord is frequently flexed by use of the appliance or tool. A good design prevents sharp bends
in the conductors that will fail due to metal fatigue of the copper strands.
Bulk/ Bundled
UNICABLE
www.unicable.com
Machine Hanked
Tied Loop Hank
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
Coiled and Tied
FAX: (714) 761-0569
FAX: (270) 843-8888
79
How to Specify Power Supply Cords
Specification Sheet
Name:
Title:
Company Name:
Address:
Phone: (
Zip Code:
)
Fax: (
Your Part Number:
)
Date:
Rev:
Quote Qty:
Per:
Ship To City:
Print Attached?
Yes
No
Sample Enclosed?
1. Wire Type:
Yes
No
Temperature Rating:
2. “A” End-Male or Female- pn:
Dimension:
3. “B” End-Open or Female-pn:
Dimension:
Live*
Neutral*
Ground*
Overall Length of Conductors
Strip Length
Twist & Tin
(Full Tin unless otherwise noted)
Open End Terminals
Describe Type of Mfg Pn
Mating Screw/Stud Size
Other
4. Overall Lengh:
6. Packaging:
5. Color**:
Bulk:
7. Strain Relief***
Hank: A.
Yes
No
B.
C.
Pn:
Coil & Tie: A.
B.
C.
Location:
8. Other Details:
* Specify NA or CEE color code.
**If color match is required enclose color chip or wire sample.
***If custom strain relief is required attach strain-relief detailed drawing.
80
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Molded Cable Assemblies
DIN Cable Assemblies
Our molded DIN and mini-DIN cables are made to meet your specific requirements. Pin configurations are shown
below. Options include coiling, shielding and pin-out. Some available in right-angle
Miscellaneous Cable Assemblies
Unicable has capabilities to produce a variety of molded and unmolded cable assemblies, including you custom design.
Tooling requires minimal time, usually ten days or less, and is very inexpensive. Some standard items available for
assembly are fused and non-fused cigarette plugs, straight and right-angle mono plugs, battery clips, sockets on ribbon
cable, etc.
Modular Keyboard Cable Assemblies
Using UL style 20512 tinned copper cable, these assemblies are built to your specifications to interconnect electronic
computers, business machines and telephone equipment. Available in 4, 6, 8 position, in straight and retractile lengths.
Molded versions are available.
Parallel Interface Cable Assemblies
For computer-printer interface, these molded assemblies have a 36 position ribbon Centronics connector on one end,
and a 25 position D-sub connector on the other end. Foil and braided shield and shielded handles are normally used to
guard against EMI and RFI.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
81
Technical Information
International Approval & Standard Agencies
AUSTRALIA
Department of Fair Trading
1 Fitzwilliam STreet Parramatta
NSW 2150
Telephone:
02-9895-0111
Fax:
02-9895-0222
AUSTRIA
Osterreichischer Verband fur
Elektrotechnik
Eschenbachgasse 9
A-1010 Wien 1
Telephone:
43-222-587-6373
Fax:
32-22-603-OEVE
ITALY
Instituto Italiano del Marchio
di Qualita
Via Quintiliano, 43
I-20138 Milano
Telephone:
39-2-507-2316
Fax:
39-2-507-3271
JAPAN
Ministry of Economy, Trade and Industry METI
3-1, Kasumgaseki, 1-Chrome, Chiyoda-ku
Tokyo
Telephone:
03-3501-1511
NETHERLANDS
Comite Electrotechnique Belge Service
Service de la Marque CEBEC
Rodestraat 125
B-1630 Linkebeek Bruxelles
Telephone:
32-2-380-8520
Fax:
32-2-380-6133
N.V. KEMA -NV tot Keuring van
Elektrotechnische Materialen
Utrechtseweg 310
Postbus 9035
NL-6800 ET Arnhem
Telephone:
31-85-56-2815
Fax:
31-85-51-4922
CANADA
NEW ZEALAND
Canadian Standards Association
178 Rexdale Boulevard
Rexdale, Ontario M9W 1R3
Telephone:
416-747-4000
Fax:
416-747-4149
Standards Association of New Zealand
181-187 Victoria Street
Privage Vag
Wellington 1
Telephone:
64-04-384-2108
Fax:
64-04-384-3938
BELGIUM
CHINA
Certification and Accreditation Administration CNCA
10(A) Chaoyangmenmei Daji
Beijing 100020
Telephone:
10-65-99-42-26
Fax:
10-65-99-46-20
DENMARK
DEMKO
Postbox 514
Lyskaer 8
DK-2730 Herlev
Telephone:
45-42-94-7266
Fax:
45-42-94-7261
FINLAND
FIMKO
SETI - Electrical Inspectorate
Sarkiniementie 3
PO Box 21
SF-00210 Helsinki 21
Telephone:
358-0-69631
Fax:
358-0-69254-74
FRANCE
UTE - Union Technique de I’Electricite
Cedex 64
F-92052 Paris la Defense
Telephone:
33-1-4723-7257
Fax:
33-1-4723-6860
GERMANY
VDE - Prufstelle
Merianstrasse 28
D-6050 Offenbech (Main)
Telephone:
49-69-8306-1
Fax:
49-69-8306-555
GREAT BRITAIN
BASEC - British Approvals Service
for Electric Cables
PO Box 390
Milton Keynes
GM-MK14 6LN England
Telephone:
44-908-31-5555
Fax:
44-908-32-0856
82
UNICABLE
www.unicable.com
NORWAY
NEMKO
Norges Elektriske Materiellkontroll
Gaustadallen 30
Postboks 73 Blindern
N-0314 Oslo 3
Telephone:
47-2-691-950
Fax:
47-2-698-636
SINGAPORE
The Safety Authority
1 Science Park Drive
Singapore 11822
Telephone:
66-773-3163
Fax:
66-778-1315
SPAIN
Asociacion Electrotecnica y
Electronica Espanola
Avda. de Brasil, 7
E-28020 Madrid
Telephone:
34-4-156-7664
Fax:
34-1-270-4972
SWEDEN
SEMKO - Svenska Electriska
Materielkontrollanstalten AB
Torshamnsgatan 43, Box 1103
S-164 22 Kista-Stockholm
Telephone:
46-8-750-0000
Fax:
46-8-750-6030
SWITZERLAND
SEV - Technische Prufanstalten
des Schweizerischer
Elektrotechnischer Verein
Postfach CH-8034
Seefeldstrasse 301
CH-8008 Zurich
Telephone:
41-1-384-9111
Fax:
41-1-551-426
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
Standards Agencies:
STANDARD ASSOCIATION
OF AUSTRALIA
BRITISH STANDARDS
INSTITUTION
CANADIAN STANDARDS
ASSOCIATION
INTERNATIONAL COMMISSION
ON RULE FOR THE APPROVAL
OF ELECTRICAL EQUIPMENT
EUROPEAN COMMITTEE FOR
ELECTROMECHANICAL
STANDARDIZATION
INTERNATIONAL
ELECTROMECHANICAL
COMMISSION
JAPANESE INDUSTRIAL
STANDARDS OFFICE
DEUTSCHE INDUSTRIE NORM
FAX: (714) 761-0569
FAX: (270) 843-8888
Technical Information
International Wire Coding Systems
European “Harmonized” Cordage Types
H05VV_ _F 3G 0.75
Type:
“H”: Harmonized or “A”: Other Standard
Voltage Rating:
“03”: 300/300V, “05”: 300/500V, “07”: 450/750V
Conductor Insulation:
Cable Jacket:
V: PVC, R: Rubber (Natural or Synthetic), N: Polychloroprene Rubber,
S: Silicone Rubber, J: Glass Fiber Construction
V: PVC, R: Rubber (Natural or Synthetic), N: Polychloroprene Rubber, T: Textile Construction
Special Component:
Rarely Used
Construction Detail:
H: Flat, separate cable, H2: Flat, non-separate cable
Conductor Type:
U: Solid, R: Stranded, K: Fine wire - fixed install, F: Fine wire - flexible cordage,
H: Extra-fine wire - flexible cordage, Y: Tinsel cord
Number of Conductors:
Dimension of Conductor:
2 or 3
“0.75”: in mm², G: ground wire, X: without ground wire
HD-21 is the harmonized standard for PVC insulated cables and flexible cords.
HD-22 is the harmonized standard for rubber insulated cable and flexible cords.
Japanese Cordage Types
HV CTF
High Temperature:
H
Conductor Insulation/Jacket:
Construction:
V: Polyvinyl Chloride, N: Neoprene, H: Hypalon, C: Bare copper
TF: Twin twisted flexible (jacketed), FF: Flat flexible (parallel), K: Oval construction
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
83
Technical Information
UL Cord Type Designation
North American Cordage Type
Designation
HSJ
HSJO
HPN
SJ
SJO
SJOO
SO
SOO
ST
STO
STOO
SP-1
SP-2
SP-3
SPT-1
SPT-2
SPT-3
SPE-1
SPE-2
SPE-3
NISPT-1
NISPT-2
Heater Service Junior
HSJ with Oil-Resistant Jacket
Heater Parallel Neoprene
Service Junior
SJ with Oil-Resistant Jacket
SJO with Oil-Resistant Insulation
S with Oil-Resistant Jacket
SO with Oil-Resistant Insulation
Service Thermoplactic
ST with Oil-Resistant Jacket
STO with Oil-Resistant Insulation
Service Parallel-2/64 Insulation
Service Parallel-3/64 Insulation
Service Parallel-4/64 Insulation
SP Thermoplastic-2/64 Insulation
SP Thermoplastic-3/64 Insulation
SP Thermoplastic-4/64 Insulation
SP Elastomer-2/64 Insulation
SP Elastomer-3/64 Insulation
SP Elastomer-4/64 Insulation
Non-Integral SPT-1
Non-Integral SPT-2
SE
SEO
S
SEOO
SJE
SJEO
SJEOO
SJT
SJTO
SJTOO
SV
SVO
SVOO
SVT
SVTO
SVTOO
SVE
SVEO
SVEOO
TPT
TST
XT
Serive Elastomer
SE with Oil-Resistant Jacket
Service
SEO with Oil-Resistant Insulation
Service Junior Elastomer
SJE with Oil-Resistant Jacket
SJEO with Oil-Resistant Insulation
Service Junior Thermoplastic
SJT with Oil-Resistant Jacket
SJTO with Oil-Resistant Insulation
Service Vacuum
SV with Oil-Resistant jacket
SVO with Oil-Resistant Insulation
Service Vacuum Thermoplastic
SVT with Oil-Resistant Jacket
SVTO with Oil-Resistant Insulation
Service Vacuum Elastomer
SVE with Oil-Resistant Jacket
SVEO with Oil-Resistant Insulation
Tinsel Parallel Thermoplastic
Tinsel Service Thermoplastic
Christmas Tree Thermoplactic
Notes:
* Thermoplastic insulation and jacket are PVC (polyvinyl chloride).
* Elastomer insulation and jacket are thermoplastic elastomer (TPE).
* Designation without “T” or “E” indicates insulation and jacket are thermoset rubber.
* “W” added, (e.g. SJTW, SOW, SPT-2W, etc.) means the insulation is water resistant AND the jacket is sunlight
resistant AND the cord is suitable for use in cold termperatures.
* Type designations are harmonized with UL and CSA (Underwriters Laboratories and Canadian Standards Association).
* Service Parallel types - integral construction includes insulation and jacket combined.
Cord Current Carrying Capacity in Amperes
AWG
Tinsel Cord
27
0.50
18
--17
--16
--14
--12
--10
--8
--6
--4
--REF: NEC Table 400-5(A)
84
UNICABLE
www.unicable.com
Rubber & Plastic Cords
--10
12
13
18
25
30
40
55
70
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
Heater Cords
--10
--15
20
30
35
-------
FAX: (714) 761-0569
FAX: (270) 843-8888
Technical Information
UL Cord Type Construction & Rating
Cord Type
AWG
Size Range
No. Of
Conductors
Conductor
Insulation
TPT
SP-1
SPT-1
27 (Tinsel)
18
18
2
2+
2+
0.030 Plastic
0.030 Rubber
0.030 Plastic
60
60
60
SP-2
SPT-2
SP-3
SPT-3
18-16
18-16
18-12
18-10
2+
2+
2+
2+
0.045
0.045
0.060
0.060
Rubber
Plastic
Rubber++
Plastic++
60
60
60
60
TS
TST
SV
SVE
SVEO
SVO
27 (Tinsel)
27 (Tinsel)
18
18-17
18-17
18
2
2
2+
2+
2+
2+
0.015
0.015
0.015
0.015
0.015
0.015
Rubber
Plastic
Rubber
Elastomer
Elastomer
Rubber
SVT
SVTO
SJ
18-17
18-17
18-10
2+
2+
2-4
0.015 Plastic
0.015 Plastic
0.030 Rubber++
SJE
SJEO
SJO
SJT
SJTO
S
SE
SEO
18-10
18-10
18-10
18-10
18-10
18-2
18-2
18-2
2-5
2-5
2-4
2-4
2-4
2+
2+
2+
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
SO
ST
STO
SRD±
18-2
18-2
18-2
10-4
2+
2+
2+
3 or 4
0.030
0.030
0.030
0.045
SRDT±
HPN (Flat)
HSJ
10-4
18-12
18-12
3 or 4
2+
2-4
0.045 Rubber
0.045 Neoprene+++
0.030 Neoprene
HSJO
HS
HSO
18-12
14-12
14-12
2-4
2-4
2-4
0.030 Neoprene++
0.045 Neoprene
0.045 Neoprene
Jacket
0.030
0.030
0.030
0.030
0.030
0.030
Rubber
Plactic
Rubber
Elastomer
Elastomer
Neoprene
Temp. Rating**
Std.
Other
75,90,105
75,90,105
75,90,105
Voltage
Rating
250
300
300
300
300
300
300
60
60
60
105
105
60
75,90
125
125
300
300
300
300
0.030 Plastic
0.030 Plastic
0.030 Rubber++
60
60
60
75,90,105
75,90,105
75,90
300
300
300
Elastomer
Elastomer
Rubber++
Plastic++
Plastic++
Rubber++
Elastomer
Elastomer
0.030
0.030
0.030
0.030
0.030
0.060
0.060
0.060
Elastomer
Elastomer
Neoprene
Plastic
Plastic
Rubber++
Elastomer
Elastomer
105
105
60
60
60
60
105
105
75,90,105
75,90,105
75,90,105
75,90
300
300
300
300
300
600
600
600
Rubber++
Plastic++
Plastic++
Plastic
0.060
0.060
0.060
0.060
Neoprene++
Plastic++
Plastic++
Rubber
60
60
60
60
75,90
75,90,105
75,90,105
600
600
600
300
90
105
0.030 Rubber
60
90
90
300
300
300
0.030 Neoprene
0.060 Rubber
0.060 Neoprene
90
90
90
0.060 Plastic
75,90
300
300
300
* Types SVO, SVTO, SJO, SJTO, SO, STO, HSJO, & HSO have jackets which are also recognized for oil resistance at 60ºC and lower
temperatures. Types SJ, SJO, SJT, SJTO, S, SO, ST, STO, SPT-1 & SPT-2 may be made for outdoor use, with “W” printed on the
jacket after the type designation (example: Type SJTW) “W” cords are suitable for “Water Resistant” use. Types TPT, SPT-1, SPT-2,
SPT-3, HPN, SVO, SJO, SJT, SJTO, SO, ST, & STO (the parallel condeuctor types are limited to 2 conductor construction) may be
made in retractile form. Types SV, SVO, SVT, SVTO, SJ, SJO, SJT, SJTO, S, SO, ST, & STO may be made with foil serve, or braid
shields under the jacket and are printed “Shielded”. Type SJT in 3 conductors may be made in special low leakage constructions for
medical applications.
** Termperature ratings higher than 60ºC are printed on jacket except for heater cordage type HPN 90ºC or 105ºC, HSJ, HSJO, HS &
HSO heater cordage is rated 90ºC for core only, while termperature printed on outside applies to jacket only.
+ Also recognized by Underwriters’ Laboratories, Inc. in 3 conductors when the third conductor (with green insulation) is used for
appliance or equipment grounding.
++ Insulation and jacket thickness depend on cord size. Thickness shown are for 18 & 16 awg.
+++ HPN may use CPE (Chlorosulfonated polyethylene) to enhance color stability.
± Note SRD & SRDT in 3 conductor versions can be made in braidless parallel construction with 0.110” nominal insulation.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
85
Technical Information
IEC 227/CEE (13) European PVC Insulated Cordage
86
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Technical Information
CEE (2) European Rubber Insulated Cordage
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
87
Technical Information
Japanese Insulated Cordage
88
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Technical Information
IEC 60320 Configurations
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
89
Wire & Cable Terminology & Abbreviations
Glossary
90
AC
Alternating current
ampere
A standard unit of current. Designated as the amount of current that occurs when one volt of
emf is applied across one ohm of resistance. An ampere of current is produced by one coulomb
of charge passing a pint in one second.
AWG
American Wire Gauge. A wire diameter specification. The lower the AWG number, the larger
the wire diameter.
AWM
Appliance Wiring Material
BC
Bare Copper
braid
A group of textile or metallic filaments interwoven to form a tubular structure which may be
applied over one or more wires, or flattened to form a strap.
bunch strand
Conductor twisted together with the same lay and direction without regards to geometric pattern.
coiled & tied
Method of coiling a cordset in a designated diameter circle, tied with wire ties at one or more
points.
CSA
Canadian Standard Association
CUL
Underwriters’ Laboratories mark for products for Canada market. Accepted in Canada as equal
to CSA.
drain wire
An uninsulated wire in contact with shield throughout its length, and used for terminating the
shield.
durometer
The measurement of hardness of a material.
EMI
Electromagnetic interference
EPDM
Ethylene-propylene-diene monomer rubber. A material with good electrical insulating
properties.
EPR
Ethylene-propylene copolymer rubber. A material with good electrical insulation properties.
fillers
Nonconducting components cabled with the insulated conductors, to impart roundness, flexibility
tensile strength, or a combination of all three, to the cable.
flex life
The ability of a cable to bend many times before breaking.
flexibility
The ability of a cable to bend in a short radius.
ground
An electrical connection to the earth, generally through a ground rod. Also a common return to a
point of zero potential, such as the metal chassis in radio equipment.
hank & tie
Method of coiling in a cordset or cable assembly in a designated size, usually a figure 8, tied in
the middle with a wire tie.
Hypalon
A Du Pont trade name for a synthetic rubber (chlorosulfonated polyethylene) used as a
insulating and jacketing materials for wire and cable.
insulation
A material having good dielectric properties which is used to separate close electrical
components, such as a cable conductors and circuit components.
jacket
Pertaining to wire and cable, the outer sheath which protects against environment and may also
provide additional insulation.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
Wire & Cable Terminology & Abbreviations
Glossary
lay
Pertaining to wire and cable, the axial distance required for one cabled conductor or conductor
strand to complete on revolution about the axis around which it is cabled.
lay direction
The twist in the cable as indicated by the top strands while looking along the axis of the cable
away from the observer. Described as “right hand” or “left hand”.
NEC
National Electric Code
NEMA
National Electrical Manufacturers Association
neoprene
A synthetic rubber with good resistance to oil, chemical, and flame. Also called polychloroprene.
plasticizer
A chemical added to plastics to make them softer and more flexible.
polyethylene
A thermoplastic material having excellent electrical properties.
polypropylene
A thermoplastic similar to polyethylene but stiffer and having higher softening point
(temperature).
PVC
Polyvinyl Chloride A general purpose thermoplastic used for wire and cable insulations and
jackets.
retractile cord
A cord having specially treated insulation or jacket so that it will retract like a spring.
Retractability may be added to all or part of a cord’s length.
shield
A sheet, screen, or braid of metal, usually copper, aluminum, or other conduction material placed
around or between electric circuits or cables or their components, to contain any unwanted
radiation, or to keep out any unwanted interference.
shield effectiveness
The relative ability of a shield to screen out undesirable radiation. Frequently confused with the
term shield percentage, which it is not.
shield percentage
The physical area of a circuit or cable actually covered by shielding material, expressed in
percent.
strain relief
A device attached to a cordset to absorb the stress on a cord, attached as a separate
component or molded to the cord.
thermoplastic
A material which will soften, flow or distort appreciably when subjected to sufficient heat and
pressure. Examples are polyvinyl chloride and polyethylene.
thermosetting
A material which will not soften, flow or distort appreciably when subjected to heat and pressure.
Vulcanizable. Examples are rubber and neoprene.
tinning
Dipping the stripped leads of a conductor into solder to a specified length.
tinsel
A type of electrical conductor comprised of a number of tiny threads, each thread having a fine,
flat ribbon of copper or other metal closely spiraled above it. Used for small size cables
requiring limpness and extra-long flex life.
thermal rating
The temperature range in which a material will perform its function without undue degradations.
UL
Underwriters Laboratories, Inc.
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
91
Technical Information
NEMA Configurations
92
UNICABLE
www.unicable.com
California: (800) GET-CORD
Kentucky: (800) FOR-CORD
FAX: (714) 761-0569
FAX: (270) 843-8888
511 South Harbor Boulevard, Unit I
La Habra,CA90631
Tel: 562-383-9278
Fax: 562-383-9279
Download