DWYER INSTRUMENTS, INC.

advertisement
001.qxd:pg2
6/6/11
1:49 PM
Page 1
Dwyer Instruments, Inc. produces a broad range of competitively priced precision instruments for measuring, transmitting and
controlling pressure, temperature, level and flow.
Many of these instruments are widely known by their individual brand names, such as Magnehelic® and Spirahelic® pressure
gages, Photohelic® switch/gages, Rate-Master®, Mini-Master® and Visi-Float® flowmeters, Slack Tube® and Flex-Tube®
manometers, and Dwyer® pressure switches.
Other established Dwyer brands, including Flotect® flow and level switches, Hi-Flow® valves, Self-Tune temperature controllers and Iso Verter® signal converters/isolators, are the products of companies that are now divisions of Dwyer Instruments
– Mercoid, W. E. Anderson, Proximity Controls and Love Controls.
Founded in 1931, Dwyer Instruments, Inc. moved its manufacturing and headquarters from Chicago, Illinois, in 1955, to newly
constructed, greatly-expanded facilities in Michigan City, Indiana. The company has since added three more Indiana facilities in Wakarusa, Kingsbury and Wolcott as well as manufacturing facilities in Anaheim, California; Fergus Falls, Minnesota;
and Kansas City, Missouri.
In addition to making and selling quality precision instruments, Dwyer Instruments, Inc. is committed to a standard of customer service, including competitive prices and knowledgeable, courteous technical support, that generates and sustains
long-term relationships.
DWYER INSTRUMENTS, INC.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
1
002.qxd:pg2
6/6/11
1:50 PM
Page 1
REAL PEOPLE
Courteous and professional customer service representatives are available via phone and email to process and provide assistance with your
order. Dwyer provides industry leading response time to answer your call
quickly without making you wait.
PHONE
219/879-8000
EMAIL
orders@dwyer-inst.com
PRICING
Contact us for formal quotes, Dwyer offers bids and project quotes.
Discounts are available for particular customer types based on quantities
purchased.
PHONE
219/879-8000
EMAIL
quotes@dwyer-inst.com
LARGE INVENTORY LOCATED CENTRALLY IN THE U.S.
Dwyer is committed to get you your order quickly with more than 5,000
line items in stock in our Michigan City, Indiana headquarters and in most
cases lead times less than two weeks for non-stock products.
FAST PROCESSING AND PACKING
Our dedicated shipping staff packs and ships your order the same day on
stock items ordered before 2:00 PM U.S. Central Time.
FLEXIBLE SHIPPING
Dwyer offers blanket orders for OEM’s to schedule out your product shipments to be when you need them. Contact us for details.
2
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
003.qxd:pg2
6/6/11
1:51 PM
Page 1
All of our technical sales staff are degreed engineers trained to be product
and industry experts. We listen to your needs and get you the answers you
want quickly.
WE HELP YOU FIND A SOLUTION
•
•
•
•
•
•
Product Selection
Application Assistance
Regulatory and Agency Approval Compliance
Installation Guidance
Maintenance and Repair
Product Customization for OEM’s
TO CONTACT A TECHNICAL SUPPORT ENGINEER
PHONE
219/879-8000
FAX
219/872-9057
EMAIL
tech@dwyer-inst.com
At Dwyer it all starts with innovative products designed according to the needs of our customers. We strive to
make products optimized for ease of use, dependability and manufacturability. Through our over 75 years of
manufacturing excellence, Dwyer has found the means to manufacture products cost effectively to offer the best
value to our customers. We supply the highest quality products and stand behind them. Dwyer products are trusted in applications all over the world in almost every industry.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
3
004.qxd:pg2
6/6/11
1:51 PM
Page 1
EASY ONLINE ORDERING AND ORDER STATUS
•
•
•
•
Easy to use shopping cart and check out
Prices shown for all products
Lead times shown for all products
Check Order Status – shipment and tracking information,
see all open and closed orders for the past 30 days
DWYER DIGITAL CATALOG
• Browse the catalog on the web or download to your
computer to have access to it when offline
• Search by any word or phrase in the catalog
• Print or email pages
• Add notes to any page
PRODUCT INFORMATION
•
•
•
•
•
We offer more than what is in the Dwyer catalog – more products, more options and more technical details
Instruction manuals and catalog pages in PDF format for easy viewing and download
Product dimensions viewable in web browser
Product drawings in DWG format for downloading and using in CAD software
Agency approval certificates – CE, FM, UL, CSA and ATEX
PRODUCT SEARCH
• Search by model number, keyword or series
PRODUCT CONFIGURATOR
• Create and order your own custom Dwyer product on the web
• Easy to use graphic interface lets you see all available options and select
what you need for your application
• Shows option rules so that you can see what options are not compatible
AND MORE!
• Product applications and technical guides
• Download product brochures and catalogs in PDF format
• Frequently asked questions
4
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
005.qxd:pg2
6/6/11
1:52 PM
Page 1
Differential Pressure Transmitter
RoHS
®
Digital Push-Button Calibration with One-Touch Transmitter Technology, DIN Mount Housing
OPTIONAL
TERMINAL COVER
Optional
protective cap
R
One Touch® Digital
Push Button sets
both zero & span
The Series 616KD Differential Pressure Transmitters with One-Touch®
technology are designed for simplicity making them the ideal choice for installers
and maintenance professionals.
The One-Touch® Differential Pressure Transmitters are cost-effective, compact
transmitters that reduce up front costs as well as expenses over the life of the
product. These instruments not only alleviate cumbersome turn pots typically found
in most transmitters, but eliminate entirely the need to span the instrument during
calibration. With a single digital push button, both ZERO AND SPAN are calibrated
properly, nothing else is required. No additional reference pressure sources and
separate calibration devices are necessary; no need to remove from service and
send to a lab. All that is required of the installer or user is to let the unit sit at zero
reference pressure, then push a button. That is it! The transmitter is now ready for
operation. Time savings are enormous over the life of the product compared to
traditional transmitters which require time to annually remove the product from
service plus the additional time to actually perform a complete full-span calibration.
Mounting is simple with integral mounting holes on the 616KD that are inherent to
the molded housing. The 616KD has the expanded capability to be mounted on a
35 mm DIN rail either via its side or back integral DIN rail clips. The Series 616KD
has easy-to-wire open screw terminals at the top of the housing. An optional
protective cap snaps directly to housing to cover terminals.
The One-Touch® family of Differential Pressure Transmitters are ideal for building
automation applications such as air handlers, duct pressure, variable air volume
and filter monitoring. Available models include ranges from 1 in w.c. to 20 in w.c.
depending on series.
5/16
[7.94]
5/8
[15.88]
Ø5/32 [3.97]
MOUNTING
HOLE
2 PLACES
2-1/4
[57.15]
2-13/32
[61.12]
New Products
Series
616KD
NPB-41
3-21/64
[84.53]
2-13/32
[61.12]
1/2
[12.70]
7/8
[22.23]
1-1/2
[38.10]
1-1/32
[26.19]
SPECIFICATIONS
Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±2% FS.
Stability: ±1% FS/year.
Temperature Limits: 32 to 122°F (0 to 50°C).
Pressure Limits: 2 psi (13.8 kPa).
Thermal Effect on Span: ±0.11% FS/°F (±0.19% FS/°C) typ.
Thermal Effect on Zero: 616KD-X0: 0.6%/°F (1%/°C); 616KD-X1: 0.3%/°F
(0.5%/°C); 616KD-X2: 0.2%/°F (0.33%/°C); 616KD-X3: 0.12%/°F (0.2%/°C);
616KD-X4: 0.06%/°F (0.1%/°C) FS max.
Power Requirements: 16 to 35 VDC (2 or 3 wire), 20 to 28 VAC (3 wire).
Output Signal: 4 to 20 mA or unit with field selectable 0 to 10 & 0 to 5 volt.
Zero and Span Adjustments: Push button.
Loop Resistance: DC=1000 Ω max.; AC=1200 Ω max.
Current Consumption: 21 mA max.
Electrical Connections: Screw-type terminal block.
Process Connections: Barbed, dual size to fit 1/8˝ & 3/16˝ (3 mm & 5 mm) ID
rubber or vinyl tubing.
Enclosure Rating: NEMA1 (IP20).
Mounting Orientation: Position insensitive.
Weight: 1.8 oz (51 g).
Agency Approval: CE, RoHS.
ACCESSORY
A-480, Plastic Static Pressure Tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$0.80
A-618, Protective Terminal Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.00
Model
616KD-00
616KD-01
616KD-02
616KD-03
616KD-04
616KD-05
616KD-06
616KD-07
616KD-10
616KD-11
616KD-12
616KD-13
616KD-14
Range
Price
0 to 1 in w.c. $62.00
0 to 2 in w.c.
62.00
0 to 3 in w.c.
62.00
0 to 5 in w.c.
62.00
0 to 10 in w.c. 62.00
0 to 5 in w.c.
62.00
0 to 20 in w.c. 62.00
0 to 25 in w.c. 62.00
0 to 250 Pa
62.00
0 to 500 Pa
62.00
0 to 750 Pa
62.00
0 to 1250 Pa
62.00
0 to 2500 Pa
62.00
Note: For selectable 0 to 10 / 0 to 5 volt output models, add -V to end of model.
Ex: 616KD-01-V.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
5
006:pg2
6/6/11
1:53 PM
Page 1
NPB-41
New Products
Series
HADP
High Accuracy Differential
Pressure Transmitter
±0.14% FS Accuracy, NIST Certificate Included
4x 6-32UNC-2B
7/64 [2.78] MIN FULL THRD
1-3/32 CABLE
4x Ø5/32 [Ø3.97]
1/8-27
33/64
MOUNTING HOLES
NPT PORT [27.78] 2´ LONG
7/8
2-3/32 [13.1]
[22.23]
[53.18]
1-1/16
[26.99]
1-1/2
[38.1]
1-1/16
[26.99]
5/8
1/8
[15.88]
Ø2-47/64
[3.18]
3/16
[69.45]
[4.76]
1/8
5/16
3
[3.18]
5/16
[7.94]
2
[76.2]
[7.94]
[50.8]
3-1/4
[82.55]
Series HADP Differential Pressure Transmitter combines low ranges with
exceptional stability, reliability and an outstanding accuracy of ±0.14% FS. All models
come with NIST certificates and are available in unidirectional and bi-directional ranges
as low as 0 to 0.5 in w.c. and 0 to 5 psid. These transmitters are ideal for a variety of
applications such as HVAC control, leak detection, medical instrumentation, clean rooms,
energy management, and environmental testing. With minimal thermal effects and the
ability to withstand high overpressures, the Series HADP transmitters are extremely
stable allowing for use in the most demanding applications.
Model
HADP-UV-00
HADP-UV-01
HADP-UV-02
HADP-UV-03
HADP-UV-04
HADP-UV-05
HADP-UC-00
HADP-UC-01
HADP-UC-02
HADP-UC-03
HADP-UC-04
HADP-UC-05
HADP-BV-08
HADP-BV-09
HADP-BV-10
HADP-BV-11
HADP-BV-12
HADP-BV-13
HADP-BC-08
HADP-BC-09
HADP-BC-10
HADP-BC-11
HADP-BC-12
HADP-BC-13
Model
HADP-UV-06
HADP-UV-07
HADP-UC-06
HADP-UC-07
HADP-BV-14
HADP-BV-15
HADP-BC-14
HADP-BC-15
Range in w.c.
0 to 0.5
0 to 1
0 to 2.5
0 to 5
0 to 15
0 to 30
0 to 0.5
0 to 1
0 to 2.5
0 to 5
0 to 15
0 to 30
0 to ±0.25
0 to ±0.5
0 to ±1
0 to ±2.5
0 to ±7.5
0 to ±15
0 to ±0.25
0 to ±0.5
0 to ±1
0 to ±2.5
0 to ±7.5
0 to ±15
Range psid
0 to 5
0 to 10
0 to 5
0 to 10
0 to ±2.5
0 to ±5
0 to ±2.5
0 to ±5
Max Pressure
High Port
5 psi
7 psi
10 psi
20 psi
50 psi
50 psi
5 psi
7 psi
10 psi
20 psi
50 psi
50 psi
5 psi
7 psi
10 psi
20 psi
50 psi
50 psi
5 psi
7 psi
10 psi
20 psi
50 psi
50 psi
Max Pressure
High Port
75 psi
100 psi
75 psi
100 psi
75 psi
100 psi
75 psi
100 psi
Max Pressure
Low Port
2.5 in w.c.
5 in w.c.
12.5 in w.c.
25 in w.c.
75 in w.c.
150 in w.c.
2.5 in w.c.
5 in w.c.
12.5 in w.c.
25 in w.c.
75 in w.c.
150 in w.c.
2.5 in w.c.
5 in w.c.
12.5 in w.c.
25 in w.c.
75 in w.c.
150 in w.c.
2.5 in w.c.
5 in w.c.
12.5 in w.c.
25 in w.c.
75 in w.c.
150 in w.c.
Max Pressure
Low Port
25 psi
50 psi
25 psi
50 psi
25 psi
50 psi
25 psi
50 psi
SPECIFICATIONS
Service: Compatible non-conducting
air/gas.
Wetted Parts:
Positive (high) Pressure Port:
Gases compatible with SS, hard
anodized 6061 aluminum (Buna-N
O-ring);
Reference (low) Pressure Port:
Anodized aluminum, alumina
ceramics, gold, fluorocarbon
elastomer sealant & Buna-N O-ring.
Accuracy: < ±0.14% FS; Optional:
±0.073% FS.
Stability: < ±0.1% FS over 6 months
@ 70°F (21°C).
Pressure Limits: See Model Chart.
Temperature Limits:
Operating: 0 to 175°F
(-18 to 71°C), optional: -65 to 250°F
(-53 to 121°C);
Storage: -65 to 250°F
(-53 to 121°C).
Compensated Temperature Range:
30 to 150°F (-1 to 65°C).
Thermal Effect: < ±1.0% FS/100°F.
Power Requirements: 17 to 42 VDC
for current models, 22 to 30 VDC for
voltage models.
Output Signal: 4 to 20 mA for current
models, 0 to 5 VDC for voltage models.
Zero and Span Output:
Zero output: Factory set to within
±0.07 mA;
Span (FS) output: Factory set to
within ±0.07 mA.
Loop Resistance:
Min. supply voltage (VDC) = 17
+ 0.02 x Resistance of receiver plus
line;
Max. supply voltage (VDC) =
42 + 0.004 x Resistance of receiver
plus line.
Zero and Span Adjustments: None.
Response Time: < 5 ms.
Current Consumption: < 30 mA.
Electrical Connections: 2 ft multiconductor cable.
Process Connections: 1/8˝-27 NPT
internal (both positive and negative
ports).
Mounting Orientation: Pressure port
90° parallel to ground.
Thermal Effects: Max. zero: ±1.0
(±1.8); %FS/100°F (100°C) max.
Weight: 8 oz (227 g).
Agency Approval: CE.
All Series HADP Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$1249.00b
OPTIONS
To order option, add suffix to part number, i.e. HADP-UV-00-T1.
- T1 Expanded temp range -65 to 250°F (-53 to 121°C) . . . . . . . . . . . .add $229.00
- A1 Improved accuracy ±0.073% FS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109.00
b Items are subject to Schedule B discounts.
Note: HADP-XV-XX is for voltage, and HADP-XC-XX is for current.
6
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
007:pg2
6/6/11
1:56 PM
Page 1
High Accuracy Pressure Transmitter
New Products
Series
HATX
NPB-41
±0.05% FS Accuracy, 0.01% Repeatability FS, NIST Certificate Included
4X DRILLED & TAPPED
6-32 x 15/64 DP [5.95 DP] 4x MOUNTING HOLES
.625
FOR NO. 6 SCREWS
[15.88]
1-1/16
Ø5/32 [Ø3.97]
[26.99]
POSITIVE
PRESSURE PORT
1/8-27 NPT INTERNAL
REFERENCE
PRESSURE PORT
1/8-27 NPT INTERNAL
3-7/64
[78.98]
1-45/64
[43.26]
13/16
[20.64]
Series HATX Pressure Transmitter combines high accuracy with
exceptional stability and reliability for environmental tests and measurements.
All models come with NIST certificates and are available in barometric,
absolute, and gage ranges. These transmitters are ideal for a variety of
applications such as weather data systems, laser interferometers, altimeter
setting indicators, and engine test cells. Series HATX transmitters consume a
very low amount of power and possess an exceptionally fast warm-up and
response time. With its excellent consistency and great performance, the
HATX transmitter is well suited for the most demanding of applications.
All Series HATX Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$1499.00b
OPTIONS
To order option, add suffix to part number, i.e. HATX-A-10-T1.
- T1 Expanded temperature range -13 to 150°F (-25 to 65°C) .add $459.00
- A1 Improved accuracy ±0.03% FS . . . . . . . . . . . . . . . . . . . . . . .add 279.00
b Items are subject to Schedule B discounts.
Model
HATX-A-10
HATX-A-11
HATX-A-12
HATX-A-13
Model
HATX-G-20
HATX-G-21
HATX-G-22
HATX-G-23
HATX-G-24
Model
HATX-B-00
HATX-B-01
Absolute Range (psia)
0 to 10
0 to 20
0 to 50
0 to 100
Gage Range (psig)
0 to 5
0 to 10
0 to 20
0 to 50
0 to 100
Barometric Range (hPa/mb)
800 to 1100
600 to 1100
CALL TO ORDER:
U.S. Phone 219 879-8000
•
61/64
[24.21]
3-17/64
[82.95]
SPECIFICATIONS
Service: Non-conducting air/gas.
Wetted Materials: Anodized
aluminum, alumina ceramics,
gold, fluorocarbon elastomer
sealant & Buna-N O-ring.
Accuracy: < ±0.05% FS;
optional: ±0.03% FS.
Stability: < ±0.1% FS over 6
months @ 70°F.
Pressure Limits:
Barometric Ranges:
800 to 1100 hPa/mb;
600 to 1100 hPa/mb: 20 psia.
Absolute and Gage Ranges:
1.5 x of std range.
Temperature Limits:
Operating: 0 to 175°F
(-18 to 71°C), optional: -13 to
150°F (-25 to 65°C);
Storage: -65 to 250°F
(-53 to 121°C).
Compensated Temperature
Range: 30 to 120°F (-1 to 49°C).
Thermal Effect:
Barometric Ranges:
< ±0.2% FS/100°F;
psig and psia Ranges:
< ±0.1% FS/100°F.
U.K. Phone (+44) (0)1494-461707
•
3
[76.2]
Ø2-45/64
[68.66]
1-29/64
[36.91]
1-61/64
[49.61]
7/8
[22.23]
Power Requirements: 22 to 30
VDC.
Output Signal: 0 to 5 VDC.
Zero and Span Output:
Zero output: Factory set to
within ±5 mV;
Span (FS) output: Factory set
to within ±5 mV.
Zero and Span Adjustments:
None.
Response Time: < 10 ms.
Current Consumption: <10 mA.
Electrical Connections: 2 ft
multi-conductor cable.
Process Connections: 1/8˝-27
NPT internal.
Mounting Orientation: Pressure
port 90° parallel to ground.
Weight: 9 oz (255 g).
Agency Approval: CE.
Australia Phone (+61) (0) 2 4272 2055
7
008:pg2
6/6/11
1:57 PM
Page 1
NPB-41
New Products
Series
AVUB
Air Velocity Transmitter
Ideal for Monitoring Air Flow in Building Automation Systems
3-11/32
[85.0]
3/4
[19.0]
51/64
[2.0]
8-55/64
[225.0]
9-29/64
[240.0]
Our popular AVU Series Transmitter is now available in an even more competitively
priced package with the new AVUB Series Air Velocity Transmitter. The Series
AVUB Transmitter operates by measuring the heat loss from its sensing element in the
air-stream and calculating the air velocity by reading the local temperature of the air on
its probe. Units are virtually immune to drift due to the design of the sensing element,
which makes the transmitter accurate over the entire air velocity range. The Series AVUB
offers 8% accuracy at a surprisingly low cost. Models are available in three ranges of 0 to
785 fpm (0 to 4 m/s), 0 to 1575 fpm (0 to 8 m/s), and 0 to 3150 fpm (16 m/s) with a 0 to 10
VDC output. The Series AVUB is ideal for a wide range of HVAC measurement and
control applications, particularly in complete building control and energy management
systems.
FEATURES
• 0 to 10 V output
• NEMA 6 (IP67) enclosure rating
• AC or DC powered
• 8% accuracy
2-1/4
[57.0]
SPECIFICATIONS
Service: Clean air and compatible, non-combustible gases.
Accuracy: ±8% of FS.
Response Time (90%): 10 s (typical).
Temperature Limits: 32 to 104°F (0 to 40°C).
Humidity Limits: 0 to 90% RH, non-condensing.
Power Requirements: 24 VDC or 24 VAC +10% to 15%.
Output Signal: 0 to 10 VDC.
Max. Start Up Current: 60 mA + output current.
Electrical Connections: Screw terminal. Cable gland for 4 to 8 mm
wire (16 ga wire).
Enclosure Rating: NEMA 6 (IP67) except sensing point.
Mounting Orientation: Unit not position sensitive. Probe must be
aligned with airflow.
Weight: 8.8 oz (250 g).
APPLICATIONS
• Supply and exhaust fan tracking
• Clean room systems
• Air pollution studies and manufacturing
• Process control systems
Model
AVUB-1-V
AVUB-2-V
AVUB-3-V
Range
Output
Price
0 to 785 fpm (0 to 4 m/s) 0 to 10 VDC $225.00b
0 to 1575 fpm (0 to 8 m/s) 0 to 10 VDC 225.00b
0 to 3150 fpm (0 to 16 m/s) 0 to 10 VDC 225.00b
b Items are subject to Schedule B discounts.
8
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
009:pg2
6/7/11
10:21 AM
Page 1
Averaging Flow Sensor
Ideal for Sensing Fan Flow Rates
MOUNTING HOLES
2XØ3/16 [Ø4.76]
FOAM GASKET
1/4 THK
[6.35 THK]
PUSH-ON
CONNECTIONS
FOR 3/8
POLY TUBING
[9.53 OD]
3-1/2
[88.90]
New Products
Series
PAFS-1000
NPB-41
2-3/4
[69.85]
7/16
[11.11]
1-1/4
[57.15]
The Series PAFS-1000 Averaging Flow Sensor is ideal for sensing
differential pressure in the inlet section of variable air volume terminal units
and fan terminal units. Units can also be used to sense differential pressure at
other locations in the main or branch duct systems.
The “H” port senses total pressure and the “L” port senses static pressure.
The difference between these signals is the differential, or velocity pressure.
For models PAFS-1002 to PAFS-1005, up to four sensing points and lengths of
3-5/32˝ to 9-29/32˝ (8.02 to 25.26 cm) to accommodate box size diameters of 4˝
to 16˝ (10.16 to 40.64 cm) are available. For models PAFS-1006 to PAFS -1011,
up to 10 sensing points and lengths from 12-1/2˝ to 23-29/32˝ (31.75 to 60.72
cm) are available to accommodate appropriately sized duct dimensions.
APPLICATION
• Zone control in HVAC systems
CALL TO ORDER:
U.S. Phone 219 879-8000
•
A
SPECIFICATIONS
Service: Air and compatible gases.
Wetted Materials: ABS/polycarbonate (UL94-5V).
Temperature Limits:
Operating: 40 to 120°F (4 to 49°C);
Storage: -40 to 140°F (-40 to 60°C).
Process Connection: 1/4˝ (6 mm) ID, 3/8˝ (10 mm) OD tubing.
Mounting Orientation: Integral flange with gasket.
Weight: 1 oz (28 g).
Model
PAFS-1002
PAFS-1003
PAFS-1004
PAFS-1005
PAFS-1006
PAFS-1007
PAFS-1008
PAFS-1009
PAFS-1010
PAFS-1011
Length (Dimension A)
3-5/32˝ (8.02 cm)
5-13/32˝ (13.73 cm)
7-21/32˝ (19.55 cm)
9-29/32˝ (25.26 cm)
12-1/2˝ (31.75 cm)
14-3/4˝ (37.47 cm)
17-1/8˝ (43.50 cm)
19-13/32˝ (49.29 cm)
21-21/32˝ (55.01 cm)
23-29/32˝ (60.72 cm)
U.K. Phone (+44) (0)1494-461707
•
Price
$7.25
8.50
10.50
13.50
29.00
34.00
34.00
43.00
47.00
52.00
Australia Phone (+61) (0) 2 4272 2055
9
010:pg2
6/6/11
2:01 PM
New Products
NPB-41
Page 1
Series
GSTA
Carbon Monoxide Gas Transmitter
High Accuracy Electrochemical Sensor, Universal Output
3-23/64
[85]
2-55/64
[73]
2-15/64
[57]
4x Ø13/64
[5.16]
MOUNTING HOLES
2-15/64
3-1/8
[56.75]
[107.95]
3-45/64
[94.06]
3-1/8
[107.95]
4-17/32
[115.09]
4-17/32
[115.09]
5-7/64
[129.78]
The Series GSTA Carbon Monoxide Transmitter monitors the gas
concentration in underground parking garages and loading docks. Carbon
monoxide is commonly used to measure the exhaust of gasoline engines. Field
selectable current and voltage outputs allow the transmitter to be used with
almost any building management controller. The user can select the output range
to be 0 to 200 ppm or 0 to 500 ppm. The output can be inverted to read 20 to 4
mA or 10 (5) to 0 VDC using internal dip switches.
To maximize the accuracy of the Series GSTA, the sensor can be field-calibrated
using the A-449 remote LCD display. When the sensor reaches the end of its life,
the display will indicate that the sensor needs to be replaced.
Gas Sensed Price
Model
CO
$175.00
GSTA-C
225.00
GSTA-C-D CO
ACCESSORIES
A-449, Remote LCD Display allows remote
indication of select Dwyer Wall Mount
Transmitters for validation or certification
purposes . . . . . . . . . . . . . . . . . . . . . . . . . .$50.00
A-505, CO Replacement Sensor . . . . . . .50.00n
n Items are net priced and are not subject to any discount.
10
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
3-59/64
[100]
SPECIFICATIONS
Sensor: Field replaceable electrochemical, 4 years typical lifespan.
Recommend calibration every 6 months.
Range:
CO: switch selectable 200 or 500 ppm;
Output Drift: <5%/yr in air.
Coverage Area: 5000 to 7500 sq ft typical.
Accuracy: CO=2% FS at the time of calibration.
Resolution: CO=1 ppm.
Temperature Limits: -4 to 122°F (-20 to 50°C).
Storage Temperature: For best sensor life, 32 to 68°F (0 to 20°C).
Humidity Range: 15 to 90% RH constant; 0 to 99% RH intermittent.
Response Time: <45 s to 90% CO.
Span and Zero Adjustment: Via pushbutton, using optional A-449
display.
Housing: UV resistant glass filled polycarbonate.
Output:
Switch selectable 4 to 20 mA (loop powered), 0 to 5 V @ 5 mA, or 0
to 10 V @ 5 mA;
Switch selectable 0 to 5 V / 1 to 5 V and 0 to 10 V / 2 to 10 V;
Switch selectable normal or reverse output.
Power Supply:
Current output: 10 to 35 VDC;
Voltage output: 15 to 35 VDC or 15 to 29 VAC.
Electrical Connection: Removable terminal block, knocks out for
conduit fitting.
Calibration: Via pushbuttons using A-449 auxiliary display. Span gas
concentration is field selectable.
Weight: 1 lb (.45 kg).
Agency Approval: CE.
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
011:pg2
6/7/11
10:29 AM
Page 1
Carbon Dioxide/Temperature Transmitter
NDIR Sensor, Universal Outputs, Optional Relay
35/64
[13.89]
3x 3/8
[9.53]
1-3/16
[30.20]
1-3/16
[30.20]
7/8
[22.35]
1-13/32
[35.72]
4-31/64
[113.9]
New Products
Series
CDT
NPB-41
4x 3/16
[4.76]
1-53/64
[46.43]
3-13/32
[86.52]
Series CDT Carbon Dioxide and Temperature Transmitters accurately monitor
the CO concentration and temperature in schools, office buildings, and other indoor
environments to help achieve LEED® certification. For increased sensor life, a single-beam
dual-wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct
the measurement in both occupied and unoccupied buildings against aging effects. The
single-beam dual-wavelength sensor technology provides the highest level of accuracy
compared to Automatic Baseline Correction methods which can unintentionally shift the
calibration based on CO levels and barometric pressure conditions. In order to achieve a
higher level of accuracy, the Series CDT includes digital barometric pressure adjustment
and the ability to field-calibrate the sensor.
2
2
Universal outputs allow users to select the transmitter output to be 4 to 20 mA, 0 to 5
VDC, or 0 to 10 VDC to work with virtually any building management controller. An
optional relay with user adjustable set points can be used to control exhaust fans, open
actuated windows or dampers, or signal a light or horn.
For applications that require visual indication, the Series CDT can be ordered with an
integral LCD display or the Model A-449 remote LCD display that can plug into the miniconnector port on the side of the transmitter. The display can be configured to display
temperature only, CO only, or CO and temperature together. Push buttons are standard
on the transmitters for access to the menu structure, but the transmitter can be ordered
without the buttons. To prevent tampering, the action of the buttons can be locked out
using an internal jumper selection. Menu items that can be accessed include: engineering
units, relay output set points, display configuration, transmitter output scaling, ambient
barometric pressure, and field calibration of the transmitter.
2
2
Single beam dual-wavelength sensor advantages:
• Automatically corrects for aging effects in occupied and unoccupied buildings*
o
Perfect for hospitals and manufacturing plants that are occupied 24 hours per
day
• Measures actual unfiltered light intensity directly
o
Eliminates error from incorrect assumptions of gas concentration in theoretical
logic assumption methods
*For buildings occupied 24 hours per day, it is recommended that calibration be
verified every 6 to 12 months depending on application.
1-13/32
[50.01]
SPECIFICATIONS
Sensor: Single beam, dual-wavelength NDIR.
Range:
CO2: 0 to 2000 or 0 to 5000 ppm (depending on model);
Temperature: 32 to 122°F (0 to 50°C).
Accuracy: ±40 ppm + 3% of reading.
Temperature Dependence: ±8 ppm/°C at 1100 ppm.
Non-Linearity: 16 ppm.
Pressure Dependence: 0.13% of reading per mm of Hg.
Response Time: 2 min for 99% step change.
Temperature Limits: 32 to 122°F (0 to 50°C).
Humidity Limits: 10 to 95% RH (non-condensing).
Power Requirements: 16 to 35 VDC or 19 to 28 VAC.
Power Consumption: Average: 2 w; Peak: 3.75 w.
Output:
Current: 4 to 20 mA (max. 500 Ω);
Voltage: 0 to 5 VDC or 0 to 10 VDC (min. 500 Ω);
Relay: SPST NO rated 2A @ 30 VDC;
RTD or thermistor per r-t curves (depending on model).
Weight: 5.6 oz (158.8 g).
CDT -2 W 4 4 -LCD Example: CDT-2W44-LCD
Price
0 to 2000 ppm CO range
2
0 to 5000 ppm CO range
5
Wall
W
$175.00
Configuration
4
4 to 20 mA / 0 to (5 or 10) VDC
CO Output
None
0
Temperature
4 to 20 mA / 0 to (5 or 10) VDC
4
Output
+5.00
10 KΩ NTC thermistor type III
A
+5.00
10 KΩ NTC thermistor type II
B
+5.00
3 KΩ NTC thermistor
C
+6.00
Pt100 Ω RTD
D
+6.00
Pt1000 Ω RTD
E
+6.00
20 KΩ NTC thermistor
F
+5.00
LCD LCD display
Options
+35.00
RLY Relay
+10.00
NBC No buttons
Series
Range
2
2
2
ACCESSORY
A-449, Remote LCD Display allows remote
indication of select Dwyer Wall Mount
Transmitters for validation or certification
purposes . . . . . . . . . . . . . . . . . . . . . . . . .$50.00
CALL TO ORDER:
U.S. Phone 219 879-8000
•
LEED® is a registered trademark of the U.S. Green Building Council.
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
11
012:pg2
6/6/11
New Products
NPB-41
2:04 PM
Page 1
Series
ULF
Ultrasonic Flow Transmitter
Integrated LCD Display, Non-Contact Level Sensing for Open Channel Flow
4-7/32
[107.0]
1-15/32
[37.0]
1-3/16
[30.0]
7-5/8
[194.0]
13/32
[10.0]
2˝ NPT OR 2˝ BSP
2-9/16
[65.0]
The Series ULF is an ultrasonic continuous flow measurement transmitter
perfect for maintenance free, non-contact measurement of open channels. This
series operates on ultrasonic technology and offers dependable, highly
accurate measurements. The ULF features easy programming with a 4 digit
LCD screen and a simple menu format. It is perfect for direct installation over
flumes and weirs and compensates for virtually all environmental conditions
such as vapors, gases, temperature variations, and wind. The weatherproof
NEMA 4 body makes this unit ideal for any flow measurement situation.
FEATURES
• High accuracy (0.25% of max. range)
• Automatic ambient temperature compensation
• ABS & UV resistant body
• Programmed with standard weir and flume sizes
1 [25.1]
35°
1/2˝ NPT CONDUIT OPENING
(ULF-XX-XXN)
PG9 CABLE GLAND
(ULF-XX-XXL)
3-3/4
[95.0]
2-5/32
[55.0]
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials:
Sensor: Polypropylene;
Acoustic window: ECTFE.
Ranges:
ULF-X1-XXX: 0.82 to 16.4 ft
(0.25 to 5 m).
ULF-X2-XXX: 1.96 to 49.2 ft
(0.6 to 15 m).
Accuracy: 0.25% of max. range
(at 20°C).
Resolution: 0.04˝ (1 mm).
Blind Zone:
ULF-X1-XXX: 0.8 ft (.25 m);
ULF-X2-XXX: 1.96 ft (0.6 m).
Beam Angle: 5° @ 3 db point.
Temperature Limits: -40 to
158°F (-40 to 70°C).
Temperature Compensation:
Automatic.
Pressure Limits: 13.5 to 30 psi
(0.9 to 2 bar).
Power Requirement: 18 to 28
VDC.
Output Signal: 4 to 20 mA.
Loop Resistance: Max. 750 Ω @
28 VDC.
Electrical Connections: Screw
terminal.
Conduit Connection: 1/2˝ NPT,
cable gland (optional).
Process Connection: 2˝ NPT,
1/2˝ BSP (optional).
Enclosure: Plastic enclosure:
ABS & UV resistant body.
Enclosure Rating: NEMA 4
(IP65).
Mounting Orientation: Vertical.
Failsafe: 3 min delay before
transmission of an error signal.
Memory: Non-volatile.
Display: 4 digit LCD.
Units: ft, m (optional).
Programming: 4 button.
Weight: 3.1 lb (1.4 kg).
Model
Max. Range
Price
Description
ULF-01-KFN Ultrasonic Flow Transmitter Short Range
16.4 ft (5 m) $897.50b
ULF-02-KFN Ultrasonic Flow Transmitter Standard Range 49.2 ft (15 m) 897.50b
b Items are subject to Schedule B discounts.
12
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
013:pg2
6/6/11
2:04 PM
Page 1
Surface Mount Temperature Sensor
RTD and Thermistor, 304 SS Probe, Waterproof
23.000
.250
STRIPPING LENGTH
1.000 x Ø0.250
WIRES 22AWG 7/30
BULLET PROBE STRANDED ETCHED TEFLON®
The Series S2-1 Surface Mount Temperature Sensors provide a cost effective and
reliable solution for surface contact temperature measurement of conditioned water
pipes, low pressure steam or refrigerant lines. The sensors are ideal for applications
where immersion wells are not practical to install. Models are constructed with a 1˝ (25
mm) 304 SS probe and a 23˝ stranded etched Teflon® leads.
Model
S2-11
S2-12
S2-13
S2-14
S2-15
S2-16
S2-17
S2-18
S2-19
S2-1A
S2-1B
Sensor Type
Pt 100Ω RTD
Pt 1000Ω RTD
Ni 1000Ω RTD
1000Ω Balco® RTD
10 kΩ Type II Thermistor
3 kΩ NTC Thermistor
5 kΩ NTC Thermistor
100 kΩ NTC Thermistor
20 kΩ NTC Thermistor
2252Ω NTC Thermistor
10 kΩ Type III NTC Thermistor
Price
$22.50
25.50
27.00
33.00
15.00
15.00
15.00
15.00
15.00
15.00
15.00
Model
TS485
New Products
Series
S2-1
NPB-41
.650
S2-1X NO HOUSING
SPECIFICATIONS
Accuracy:
Platinum RTD: ±0.1% @ 32°F (0°C), alpha 385 per DIN 43760;
Nickel RTD: ±0.5°F @ 70°F (21.1°C);
Balco®: ±0.5°F @ 70°F (21.1°C);
Thermistor: ±0.2°C interchangeable @ 77°F (25°C).
Operating Temperature: -40 to 250°F (-40 to 125°C).
Probe Diameter: 1/4˝ (6.3 mm).
Probe Length: 1˝ (25 mm).
Probe Material: 304 SS.
Balco® is a registered trademark of CRS Holdings, Inc.
Teflon® is a registered trademark of E.I. Dupont De Nemours and Company
RS-485 Serial Communications Module
Connects to Configuration Key Port
1-11/16
[42.86]
1-1/16
[26.99]
21/32
[16.67]
1-39/64
[40.89]
The Model TS485 Serial Communications Module allows users to read
the current temperature and parameter settings of the Love Controls family of
temperature switches. The configuration key port on the temperature switch
provides the data signal and power for the RS-485 module. For applications
with multiple temperature switches, the modules can be daisy chained together
so that only two wires need to be brought to the PC. The Model TS485 is
compatible with Series TS3, TSX3, TSF, TCS, TS2, TSS2, TSX, TSWB, TSL8,
and TSDIN.
SPECIFICATIONS
Compatible Devices: TS3, TSX3, TSF, TCS, TS2, TSS2, TSX, TSWB,
TSL8, and TSDIN.
Communication Type: RS-485 full duplex.
Electrical Isolation: 2500 VAC.
Agency Approvals: CE.
Model TS485, Serial Communications Module . . . . . . . . . . . . . . .$45.00
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
13
014:pg2
6/6/11
2:06 PM
New Products
NPB-41
Page 1
Series
CFS2
Cable Float Switch
Mercury-Free, UL/CSA Approved Options
1-41/64
[41.50]
3-3/16
[81.00]
4-9/64
[105.00]
5-5/32
[131.00]
The Series CFS2 Cable Float Switch is a mechanically actuated floating switch
intended to activate electrical components, usually pumps, to start and stop automatically.
The CFS2 is perfect for simple level control of liquids for filling or draining reservoirs and
tanks. Float switches such as the CFS2 are the most universally used for pump automation,
due to their high reliability, economical pricing, and easy installation. Counterweights and
cable hangers are available to suit a variety of mounting applications. Optional cables
available include those with UL/CSA approval, higher chemical compatibility, high
temperature durability, oil resistance, and drinking water suitability. Contact factory for
piggyback plug option, gold contact switch option and cable length options ranging from 10
to 70 ft (3.04 to 21.34 m).
ACCESSORIES
Model Description
A-457 7.76 oz (220 g) counterweight
A-459 Cable hanger
Price
$1.50
35.00
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Enclosure: Polypropylene; Cable: See model chart.
Temperature Limits: 32 to 122°F (0 to 50°C).
Pressure Limits: 14.5 psi (1 bar).
Enclosure Rating: IP68.
Switch Type: See model chart.
Electrical Rating:
CFS2-XXBXX-XX
10 (8) A @ 250 VAC.
CFS2-XXDXX-XX
1 HP @ 125 VAC 16 FLA;
2 HP @ 250 VAC 12 FLA;
Shipping Weight:
Enclosure: 5.43 oz (154 g);
Cable: 0.77 oz (21.27 g) per ft.
Agency Approvals: See model chart.
Model
CFS2-ONBPN-20
CFS2-ONBPN-30
CFS2-ONBPN-40
CFS2-ONBPN-50
CFS2-CNBPN-20
CFS2-CNBPN-30
CFS2-CNBPN-40
CFS2-CNBPN-50
CFS2-DNBPN-20
CFS2-DNBPN-30
CFS2-DNBPN-40
CFS2-DNBPN-50
CFS2-OGDSN-20
CFS2-OGDSN-30
CFS2-OGDSN-40
CFS2-OGDSN-50
CFS2-CGDSN-20
CFS2-CGDSN-30
CFS2-CGDSN-40
CFS2-CGDSN-50
14
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
6-15/64
[158.50]
Cable Type Approvals
CE
PVC
CE
PVC
CE
PVC
CE
PVC
CE
PVC
CE
PVC
CE
PVC
CE
PVC
CE
PVC
CE
PVC
CE
PVC
CE
PVC
UL/CSA
SJOW
UL/CSA
SJOW
UL/CSA
SJOW
UL/CSA
SJOW
UL/CSA
SJOW
UL/CSA
SJOW
UL/CSA
SJOW
UL/CSA
SJOW
www.dwyer-inst.co.uk
•
Switch Type
SPST NO
SPST NO
SPST NO
SPST NO
SPST NC
SPST NC
SPST NC
SPST NC
SPDT
SPDT
SPDT
SPDT
SPST NO
SPST NO
SPST NO
SPST NO
SPST NC
SPST NC
SPST NC
SPST NC
www.dwyer-inst.com.au
Cable Length
20 ft (6.10 m)
30 ft (9.14 m)
40 ft (12.19 m)
50 ft (15.24 m)
20 ft (6.10 m)
30 ft (9.14 m)
40 ft (12.19 m)
50 ft (15.24 m)
20 ft (6.10 m)
30 ft (9.14 m)
40 ft (12.19 m)
50 ft (15.24 m)
20 ft (6.10 m)
30 ft (9.14 m)
40 ft (12.19 m)
50 ft (15.24 m)
20 ft (6.10 m)
30 ft (9.14 m)
40 ft (12.19 m)
50 ft (15.24 m)
Price
$20.00
24.00
28.00
32.00
20.00
24.00
28.00
32.00
21.00
25.50
30.00
34.50
39.50
53.50
67.50
81.50
39.50
53.50
67.50
81.50
015:pg2
6/6/11
2:10 PM
Page 1
Free-Floating Level Switch
Designed for Industrial Applications, Mercury-Free, Self Counter-Weighted
New Products
Series
FSW2
NPB-41
8-23/64
[212.50]
5/8
[16.00]
4-45/64
[119.50]
The Series FSW2 Free-Floating Level Switch is a mercury-free self counterweighted floating switch designed for the automation of pumps, specifically filling and
draining of tanks, wells, and reservoirs. The FSW2 body is free of any irregularities
making it ideal for use in sewage water applications. The polypropylene body consists of a
double airtight chamber with high-pressure melted polypropylene re-injection sealing to
ensure a perfect seal against infiltration. Cable hangers are available to suit a variety of
mounting applications. Featuring CE approval and optional cables available that include
higher chemical compatibility, high temperature durability, oil resistance, and drinking
water suitability. Contact factory for piggyback plug option, and cable length options
ranging from 10 to 70 ft (3.04 to 21.34 m).
ACCESSORY
Model Description
A-459 Cable hanger
Price
$35.00
CALL TO ORDER:
SPECIFICATIONS
Service: Compatible liquids, slurries.
Wetted Materials: Enclosure: Polypropylene; Cable: PVC.
Operating Temperature: -4 to 176°F (-20 to 80°C).
Pressure Limits: 29 psi (2 bar).
Enclosure Rating: IP68.
Switch Type: See model chart.
Electrical Rating: 10 (8) A @ 250 VAC.
Mounting Orientation: Vertical.
Shipping Weight:
Enclosure: 2.4 lb (1100 g);
Cable: 0.77 oz (21.27 g) per ft.
Agency Approval: CE.
Model
FSW2-ONPN-20
FSW2-ONPN-30
FSW2-ONPN-40
FSW2-ONPN-50
FSW2-CNPN-20
FSW2-CNPN-30
FSW2-CNPN-40
FSW2-CNPN-50
FSW2-DNPN-20
FSW2-DNPN-30
FSW2-DNPN-40
FSW2-DNPN-50
U.S. Phone 219 879-8000
•
4-23/64
[110.83]
Switch Type
SPST NO
SPST NO
SPST NO
SPST NO
SPST NC
SPST NC
SPST NC
SPST NC
SPDT
SPDT
SPDT
SPDT
U.K. Phone (+44) (0)1494-461707
•
Cable Length Price
20 ft (6.10 m) $60.00
30 ft (9.14 m)
63.50
40 ft (12.19 m) 67.00
50 ft (15.24 m) 70.50
20 ft (6.10 m)
60.00
30 ft (9.14 m)
63.50
40 ft (12.19 m) 67.00
50 ft (15.24 m) 70.50
20 ft (6.10 m)
62.00
30 ft (9.14 m)
66.50
40 ft (12.19 m) 71.00
50 ft (15.24 m) 75.50
Australia Phone (+61) (0) 2 4272 2055
15
016:pg2
6/6/11
New Products
NPB-41
2:13 PM
Page 1
Series
ULB
Ultrasonic Level Transmitter for Solids
Integrated LCD Display, Automatic Temperature Compensation
4-7/32
[107.0]
1-15/32
[37.0]
1-3/16
[30.0]
7-5/8 35°
[194.0]
1/2˝ NPT
13/32
[10.0]
2˝ NPT
2-9/16
[65.0]
3-3/4
[95.0]
1 [25.1]
2-5/32
[55.0]
The Series ULB is a direct-install level transmitter designed for non-contact
measurement of solid levels. The ULB utilizes ultrasonic technology paired
with automatic temperature compensation to provide reliable and accurate
measurements in virtually all conditions. Sophisticated algorithms are used to
overcome acoustic interferences and false echoes. An integrated LCD screen
and four push buttons allow for quick and easy programming on a simple menu
structure. Diagnostic capabilities and a failsafe output signal make the ULB an
essential choice in critical applications.
FEATURES
• Direct installation
• Integral LCD display
• High accuracy (0.25% of max. range)
• Automatic ambient temperature compensation
Model Description
Max. Range
Price
ULB-11 Ultrasonic Level Transmitter 11.5 ft (3.5 m) $875.00b
Standard Range
ULB-12 Ultrasonic Level Transmitter 28 ft (8.5 m)
875.00b
Extended Range
b Items are subject to Schedule B discounts.
16
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
SPECIFICATIONS
Service: Bulk solids.
Wetted Materials:
Sensor: Polypropylene;
Acoustic window: ECTFE.
Ranges:
ULB-11: .82 to 11.5 ft (0.25 to 3.5 m);
ULB-12: 1.96 to 28 ft (0.6 to 8.5 m).
Accuracy: 0.25% of max. range (at 20°C).
Resolution: 0.04˝ (1 mm).
Blind Zone:
ULB-11: 0.8’ (.25 m);
ULB-12: 1.96’ (0.6 m).
Beam Angle: 5° @ 3 db point.
Temperature Limits: -40 to 158°F (-40 to 70°C).
Temperature Compensation: Automatic.
Pressure Limits: 13.5 to 30 psi (0.9 to 2 bar).
Power Requirement: 18 to 28 VDC.
Output Signal: 4 to 20 mA.
Loop Resistance: Max. 750 Ω @ 28 VDC.
Electrical Connections: Screw terminal.
Conduit Connection: 1/2˝ NPT, cable gland (optional).
Process Connection: 2˝ NPT, 2˝ BSP (optional).
Enclosure: Plastic enclosure: ABS & UV resistant body.
Enclosure Rating: NEMA 4 (IP65).
Mounting Orientation: Vertical.
Failsafe: 3 min delay before transmission of an error signal.
Memory: Non-volatile.
Display: 4 digit LCD.
Units: ft, m (optional).
Programming: 4 button.
Weight: 3.1 lb (1.4 kg).
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
017:pg2
6/6/11
2:27 PM
Page 1
Smart Programmable Panel Meter
RoHS
New Products
Series
SPPM
NPB-41
Fully Field Configurable, 16-Bit Color Touch Screen Display
1/2
[12.45]
3 [76.45]
SMART PROGRAMMABLE PANEL METER
2-3/8
[60.44]
1-29/32
[48.26]
(COUNTRY OF ORIGIN)
DATE CODE
15/16
[23.62]
9/32
[7.11]
1/16
[1.52]
21/32
[16.51]
23/32
[18.29]
1-11/16
[42.55]
SPPM-24
3-17/32
[89.51]
1/4
[6.71]
3-1/2
[89.10]
2-9/32
1-11/16 [57.60]
[43.22]
29/32
[23.40]
2-1/4
[56.80]
19/32
[15.19]
5/32 [3.90]
3/8 [9.80]
19/32
[15.20]
3/4
9/16
1-3/8
[19.06] 5/16 [35.12]
[14.00]
[7.70]
3-5/16
[84.10]
2-1/8
[53.81]
11/16
[17.80]
3/16
[5.07]
1/16
[1.90]
SPPM-28
The Series SPPM Smart Programmable Panel Meter is a configurable, full color
touch screen display that can be used in a variety of applications. Utilizing a USB
connection, the panel meter can be configured with downloadable software, using any
computer running Windows® based software. Available with either a 2.4˝ or 2.8˝ screen
which features remarkable graphics that can easily be customized to read and/or graph
pressure, temperature, humidity, gas concentration, or many other parameters. Up to two
transmitters or transducers can feed the panel meter’s user scalable inputs. The Model
SPPM-24 includes a gasket and mounting clip for quick installation into a panel.
Model
Description
SPPM-24 Smart Programmable Panel Meter with 2.4˝ display
SPPM-28 Smart Programmable Panel Meter with 2.8˝ display
Price
$110.00b
125.00b
ACCESSORY
SPPM-CA, Mini USB to full USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$10.00b
b Items are subject to Schedule B discounts.
Programmable Display Configurations
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Inputs: 0 to 40 VDC, scalable (factory set from 0 to 10 V).
Accuracy: 0.1%.
Resolution: 0.3 to 9.8 mV (depending on input range).
Power Supply: 30 VDC max. or via USB.
Current Consumption: 190 mA max.
Display: 2.4˝ or 2.8˝ TFT full color touch screen.
Display Resolution: 320 x 240 pixels.
Sampling Rate: 3 samples/s.
Temperature Limits: 32 to 104°F (0 to 40°C).
Warm Up: 30 s.
Mounting: Panel mount.
Electrical Connection: Screw terminals, pin connection, or USB.
Software Requirements: Compatible with Windows® XP, Windows® 2000,
Windows® 7 and Windows Vista®.
Weight: 2.8 oz (79.4 g).
Approvals: CE, RoHS.
Windows® and Windows Vista® are registered trademarks of Microsoft Corporation
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
17
018:pg2
6/6/11
New Products
NPB-41
2:29 PM
Page 1
Model
CM-1
Digital Clamp Meter
Measures DC/AC Voltage, AC Current, Resistance, Frequency
2-23/32
[69.00]
7-41/64
[194.00]
RED
BLACK
TEST LEADS
RUBBER TEST LEAD HOLDER
The compact, low cost Model CM-1 Digital Clamp Meter is ideal for general electrical
testing and troubleshooting. A few applications include HVAC, automotive,
electrical/power, and environmental monitoring uses. The digital clamp meter measures
DC and AC voltage to 600 V, AC current to 400 A, and resistance to 400 Ω. In addition
to volts, amps and ohms, this meter includes a frequency test to 400 Hz. The CM-1 also
features data/range hold and auto range buttons to keep the screen from updating when
gathering values. The 3-3/4 digit LCD features automatic polarity, overload and low
battery indication. The Model CM-1 is furnished with red and black test leads, two AAA
batteries and carrying case with belt loop.
Model CM-1, Digital Clamp Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$75.00b
b Items are subject to Schedule B discounts.
Model
CM-2
SPECIFICATIONS
Over Voltage Category: CAT III 600 V.
AC Voltage: 0.1 V to 600 V ± (1.0% + 5 digit).
DC Voltage: 0.1 V to 600 V ± (1.0% + 3 digit).
AC Current: 0.1 A to 400 A ± (2.0% + 10 digit).
Resistance: 0.1 to 400 Ω ± (1.0% + 5 digit).
Continuity Test: Audible buzzer.
Max. Conductor Size: 1.18˝ diameter (30 mm).
Frequency: 0.001 kHz to 400 Hz ± (0.8% + 3).
Display: 4000 counts plus decimal point.
Sampling Rate: 2 x per s.
Power Requirements: 2 AAA batteries.
Weight: 9.88 oz (280 g).
Digital Clamp Meter with True RMS
Measures DC/AC Voltage, DC/AC Current, Resistance
2-23/32
[69.00]
7-41/64
[194.00]
RED
BLACK
TEST LEADS
Our compact, low cost Model CM-2 Digital Clamp Meter with True RMS is ideal for
general electrical testing and troubleshooting. A few applications include HVAC,
automotive, electrical/power, and environmental monitoring uses. The Model CM-2
measures DC and AC voltage to 600 V, DC and AC current to 400 A, and resistance to 40
MΩ. The digital clamp meter features data/range hold and auto range buttons to prevent
the screen from updating when gathering values, as well as a zero function. The 3-3/4
digit LCD features automatic polarity, overload and low battery indication. The Model
CM-2 is furnished with red and black test leads, two AAA batteries and a carrying case
with belt loop.
Model CM-2, Digital Clamp Meter with True RMS . . . . . . . . . . . . . . . . .$125.00b
b Items are subject to Schedule B discounts.
18
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
SPECIFICATIONS
Over Voltage Category: CAT III 600 V.
AC Voltage: 0.1 mV to 600 V ± (1.0% + 3 digit).
DC Voltage: 0.1 mV to 600 V ± (0.8% + 2 digit).
AC Current: 10 mA to 400 A ± (2.0% + 10 digit).
DC Current: 10 mA to 400 A ± (2.0% + 10 digit).
Resistance: 0.1 to 40 mΩ ± (1.0% + 3 digit).
Continuity Test: Audible buzzer.
Max. Conductor Size: 1.18˝ diameter (30 mm).
Display: 4000 counts plus decimal point.
Sampling Rate: 2 x per s.
Power Requirements: 2 AAA batteries.
Weight: 8.64 oz (245 g).
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
019:pg2
6/6/11
2:32 PM
Page 1
Digital Clamp Meter with True RMS,
Peak Hold and Min/Max
Measures DC/AC Voltage, DC/AC Current, Energy, Resistance
New Products
Model
CM-3
NPB-41
2-3/4
[70.00]
7-61/64
[202.00]
RED
BLACK
TEST LEADS
ALLIGATOR CLIPS
Our compact, low cost Model CM-3 Digital Clamp Meter is ideal for general electrical
testing and troubleshooting. A few applications include HVAC, automotive,
electrical/power, and environmental monitoring uses. The CM-3 measures DC and AC
voltage to 600 V, AC current to 4000 A, and resistance to 2000 Ω. The digital clamp meter
features data/range hold and auto range buttons to prevent the screen from updating
when gathering values, as well as a zero function. Additional features include single and
three phase energy measurement, MIN/MAX and average. The 3-3/4 digit backlit LCD
features automatic polarity, overload, low battery indication and a bar graph. The Model
CM-3 is furnished with red and black test leads, two AAA batteries and a carrying case
with belt loop.
Model CM-3, Digital Clamp Meter with True RMS,
Peak Hold and Min/Max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$225.00b
b Items are subject to Schedule B discounts.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Over Voltage Category: CAT III 600 V.
AC Voltage: 0.1 V to 600 V ± (1.0% + 3 digit).
DC Voltage: 0.1 V to 600 V ± (1.0% + 3 digit).
AC Current: 0.1 A to 4000 A ± (12.0% + 3 digit).
Resistance: 0.1 to 2000 Ω ± (1.0% + 5 digit).
Continuity Test: Audible buzzer.
Max Conductor Size: 1.18˝ diameter (30 mm).
Frequency: 40 Hz to 400 Hz ± (0.5% + 1).
Active Power Range: 0 to 1000 kW ± (3.5% + 3).
Display: Backlit with bar graph. 10,000 counts plus decimal point.
Power Requirements: 2 AAA batteries.
Weight: 9.88 oz (280 g).
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
19
020:pg2
6/6/11
New Products
NPB-41
2:38 PM
Page 1
Model
MM-1
Digital Auto-Range Multimeter
Measures DC/AC Voltage, DC/AC Current, Resistance, Frequency, Capacitance
3-15/32
[88.00]
6-27/64
[163.00]
Our compact, low cost Model MM-1 Digital Auto-Range Multimeter is ideal for
general electrical testing and troubleshooting. This full function multimeter measures DC
and AC voltage to 600 V, DC and AC current to 10 A and resistance to 400 Ω. In addition
to volts, amps and ohms, this meter includes audible continuity, diode, LED and transistor
hFE tests. The rotary switch allows you to select from any of the functions quickly and
easily. The 4 digit backlit LCD features value, mode, and low battery indication. The
rugged, high impact case is double injected for excellent strength and durability. The
Model MM-1 is furnished with black and red test leads, two AAA batteries and carrying
case with belt loop.
Model MM-1, Digital Auto-Range Multimeter . . . . . . . . . . . . . . . . . . . . . .$67.50b
b Items are subject to Schedule B discounts.
Model
MM-2
SPECIFICATIONS
Overvoltage Category: CAT IV 600 V,
CAT III 1000 V.
DC Voltage: 0.1 mV to 600 V (0.8%
+ 2 digit).
AC Voltage: 0.001 V to 600 V (0.8%
+ 3 digit).
DC Current: 0.01 A to 10 A (1.2% + 3
digit).
AC Current: 0.01 A to 10 A (1.2% + 3
digit).
Resistance: 400, 4K, 40K, 400K, 4M,
40M ± (1.0% + 2 digit).
RED
BLACK
TEST LEADS
Protection: 600 Vrms.
Continuity Test: Audible buzzer.
Frequency: 0.01 Hz to 99.99 kHz.
Duty Cycle: 20 to 80% ± (1.0% + 5
digit).
Capacitance: 5n, 50n, 500n, 5u, 50u,
100uF ± (3% + 5 digit).
Display: Backlit, 4000 counts plus
decimal point.
Sampling Rate: 2.5 x per s.
Power Requirements: 2 AAA
batteries.
Weight: 23.5 oz (666 g).
Digital Multimeter with True RMS
Measures DC/AC Voltage, DC/AC Current Resistance, 4000 Count Digital Display
3-15/32
[88.00]
THERMISTOR
6-27/64
[163.00]
ADAPTER
RED
BLACK
TEST LEADS
Our compact, low cost Model MM-2 Digital Multimeter with True RMS is ideal for
general electrical testing and troubleshooting. This full function multimeter measures DC
voltage to 1000 V and AC voltage to 750 V, DC and AC current to 10 A and resistance to
400 Ω. In addition to volts, amps and ohms, this meter includes audible continuity, diode,
LED and transistor hFE tests. The rotary switch allows you to select from any of the
functions quickly and easily. The 4 digit backlit LCD features value, mode, and low
battery indication. The rugged, high impact case is double injected for excellent strength
and durability. The Model MM-2 is furnished with black and red test leads, 9 V battery,
thermistor with input adapter, and carrying case with belt loop.
Model MM-2, Digital Multimeter with True RMS . . . . . . . . . . . . . . . . . . .$119.00b
b Items are subject to Schedule B discounts.
20
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
SPECIFICATIONS
Overvoltage Category: CAT IV 600 V,
CAT III 1000 V.
DC Voltage: 0.1 mV to 1000 V (0.5%
+ 2 digit).
AC Voltage: 0.1 mV to 750 V (1.3%
+ 5 digit).
DC Current: 0.1 uA to 10 A (1.0% + 3
digit).
AC Current: 0.1 uA to 10 A (1.5% + 5
digit).
Resistance: 400, 4K, 40K, 400K, 4M,
40M ± (1.0% + 2 digit).
www.dwyer-inst.co.uk
•
Protection: 1000 Vrms.
Continuity Test: Audible buzzer.
Frequency: 1 Hz to 40 MHz.
Capacitance: 4n, 40n, 400n, 4u, 40u,
400u, 4m, 40mF ± (1% + 5 digit).
Temperature: -40 to 1382°F (-40 to
800°C).
Display: Backlit with bar graph. 4000
counts plus decimal point.
Sampling Rate: 2.5 x per s.
Power Requirements: 9 V battery.
Weight: 23.5 oz (666 g).
www.dwyer-inst.com.au
021:pg2
6/6/11
2:45 PM
Page 1
Digital Pen Meter
Measures DC/AC Voltage, Resistance, Continuity, Diode, Frequency
2-1/8
[54.00]
New Products
Model
PM-1
NPB-41
7-7/8
[200.00]
BLACK WIRED TEST LEAD
RED PEN TEST LEAD
Our compact, low cost Model PM-1 Digital Pen Meter is ideal for general electrical
testing and troubleshooting. A few applications include HVAC, automotive,
electrical/power, and environmental monitoring uses. This meter measures DC and AC
voltage to 600 V and resistance to 40 MΩ. In addition to volts and ohms, the digital pen
meter includes continuity, diode, and frequency tests to 10 kHz. This meter features data
hold, REL (relative value), and auto range buttons. The 4 digit LCD displays value, mode,
and low battery indication. The Model PM-1 is furnished with red and black test leads,
two AA batteries and carrying case with belt clip.
Model PM-1, Digital Pen Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$52.50b
b Items are subject to Schedule B discounts.
Model
PM-2
SPECIFICATIONS
Over Voltage Category:
CAT IV 600 V.
AC Voltage: 1 mV to 600 V
± (1.0% + 3 digit).
DC Voltage: 0.1 mV to 600 V
± (0.8% + 2 digit).
Resistance: 0.1 to 40M ohm
± (1.0% + 3).
Continuity: Audible buzzer.
Diode Test: 1.5 VDC.
Frequency: 0.001 Hz to 10 KHz ±
(0.8% + 2).
Display: 4000 counts plus decimal
point.
Power Requirements: 2 AA batteries.
Weight: 5.3 oz (150 g).
Digital Pen Meter with Phase Rotation
Measures DC/AC Voltage, Resistance, Continuity, Frequency and Phase Rotation
2-1/8
[54.00]
7-7/8
[200.00]
BLACK WIRED TEST LEAD
RED PEN TEST LEAD
Our compact, low cost Model PM-2 Digital Pen Meter is ideal for general electrical
testing and troubleshooting. A few applications include HVAC, automotive,
electrical/power, and environmental monitoring uses. This meter measures DC and AC
voltage to 600 V and resistance to 1499 Ω. In addition to volts and ohms, this meter
includes continuity, diode, and frequency tests to 69.9 Hz. Along with the mentioned
functions, the PM-2 has the ability to perform a phase test from 100 to 600 V. This meter
features data hold, display (to show voltage and frequency during AC tests), and clear
screen buttons. The 4 digit LCD features value, mode, and low battery indication. The
Model PM-2 is furnished with red and black test leads, 2 AA batteries and carrying case
with belt clip.
Model PM-2, Digital Pen Meter with Phase Rotation . . . . . . . . . . . . . . . .$84.50b
b Items are subject to Schedule B discounts.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Over Voltage Category: CAT IV 600 V.
AC Voltage: 1.5 V to 600 V ± (1.5% rdg + 5 dgt).
DC Voltage: 1.5 V to 600 V ± (0.8% rdg + dgt).
Resistance: 1 to 1499 ohm ± (1.0% + 5 dgt).
Continuity: Audible buzzer.
Phase Test: 100 to 600 V.
Frequency: 0.1 Hz to 69.9 Hz ± (1.0% + 2).
Display: 6000 counts plus decimal point.
Power Requirements: 2 AA batteries.
Weight: 5.3 oz (150 g).
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
21
022:pg2
6/7/11
10:17 AM
Page 1
NPB-41
New Products
Series
DCS/RDCS
DCS35T1D
Springless Diaphragm Valves
RDCS20C
DCS35C1D
FEATURES
• Thermoplastic polyurethane diaphragm for longer life
• High flow factor for effective cleaning
• Unique diaphragm eliminates spring
• Valve can be mounted in any position
• Quick on & off response time
ACCESSORY
A-237, Muffler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$4.80
*110 VAC with DIN Connector
Series DCS/RDCS Model Guide
DCS
Construction
RDCS
20
Size
25
35
T
Connection
C
Voltage
1D
2D
3D
22
Cv
Factor
(gal/min)
14
23
42
DIAPHRAGM VALVE CONSTRUCTION
Price
$30.00
45.00
45.00
59.00
40.00
53.00
56.00
68.00
56.00
77.00
70.00
89.00
NEMA 4X (IP65)
Solenoid Coil
Solenoid
Integrated Solenoid
Stem
Cover
Unique Diaphragm
Design Eliminates
Need for a
Spring
Integrated coil
Remote coil
3/4˝
1˝
1-1/2˝
NPT
Coupling
110 VAC DIN (for integrated coil only)
220 VAC DIN (for integrated coil only)
24 VDC DIN (for integrated coil only)
VISIT OUR WEBSITES:
www.dwyer-inst.com
RDCS35T
SPECIFICATIONS
Service: Compatible gases, filtered and oil free.
Wetted Materials:
Body: Aluminum;
Diaphragm disc: Thermoplastic polyurethane;
Solenoid seals: NBR;
Diaphragm core and spring: 304 SS.
Other Materials:
Cover: Aluminum;
Body bolts: Zinc plated SS;
Solenoid: Nylon.
Pressure Limits: Min. of 4.4 psi (0.3 bar), max. of 124.7 psi (8.6 bar).
Temperature Limits:
Ambient: -4 to 140°F (-20 to 60°C);
Operating: -4 to 185°F (-20 to 85°C).
Power Requirements: 110 VAC, 220 VAC, or 24 VDC for DCS models.
Power Consumption: 12 W; Inrush: 17 VA; Holding: 14.5 VA for DCS models.
Electrical Connection: DIN connection for DCS models.
Enclosure Rating: NEMA 4X (IP65) for DCS models.
Process Connection: See model chart.
Mounting Orientation: Any position.
Agency Approval: CE.
The Series DCS/RDCS Springless Dust Collection Valves are ideal for use with
the Series DCT1000 and Series DCT500 duct collection timer boards. A springless design
offers not only durability, but also reliability for an exceptional cleaning pulse. Both the
Series DCS and RDCS have the option for either coupling or NPT connections. The
coupling connection allows for a quick and simple installation. Only the stub pipe and
blowtube need to be cleaned and deburred before the valve is fit into position. The “T”
Series DCS has female threaded connections and the “C” Series DCS has a coupling
connection. Both the “T” and “C” versions have a 90° angle between the inlet and outlet:
the most suitable configuration for pulse valve applications. The valves are offered in both
integrated and remote coil configurations.
Number of
Model
Size Solenoid Connection Diaphragms
RDCS20T 3/4˝
Remote NPT
1
RDCS20C
Remote Coupling
DCS20T1D
Integral* NPT
DCS20C1D
Integral* Coupling
RDCS25T 1˝
Remote NPT
1
RDCS25C
Remote Coupling
DCS25T1D
Integral* NPT
DCS25C1D
Integral* Coupling
RDCS35T 1-1/2˝ Remote NPT
1
RDCS35C
Remote Coupling
DCS35T1D
Integral* NPT
DCS35C1D
Integral* Coupling
RDCS35C
Diaphragm
Robust Die Cast
Aluminum Body
Body
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
023.qxd:pg2
6/6/11
2:49 PM
Page 1
NPB-41
C
C
New Products
DCS/RDCS Dimensional Chart
F
F
B
B
E
E
D
D
DCS Dimensional Chart
Connection Model
DCS20TxD
NPT
DCS25TxD
DCS35TxD
DCS20CxD
Coupling
DCS25CxD
DCS35CxD
RDCS Dimensional Chart
Connection Model
RDCS20T
NPT
RDCS25T
RDCS35T
RDCS20C
Coupling
RDCS25C
RDCS35C
A
A
A (mm)
3-1/8˝ (79.38)
3-19/64˝ (83.74)
4-11/32˝ (110.33)
4-9/64˝ (105.17)
4-7/16˝ (112.71)
5-23/64˝ (136.13)
B (mm)
2-47/64˝ (69.45)
3-7/32˝ (81.76)
3-43/64˝ (93.27)
3-25/64˝ (86.10)
4-43/64˝ (118.67)
5-21/64˝ (135.33)
C (mm)
2-45/64˝ (68.66)
2-53/64˝ (71.83)
3-1/2˝ (88.9)
2-45/64˝ (68.66)
2-53/64˝ (71.83)
3-1/2˝ (88.9)
D (mm)
1-37/64˝ (40.08)
1-55/64˝ (47.23)
2-17/32˝ (64.29)
2-39/64˝ (66.28)
3˝ (76.20)
3-35/64˝ (90.09)
E (mm)
1-15/64˝
1-31/64˝
1-15/32˝
1-51/64˝
2-49/64˝
2-61/64˝
(31.35)
(37.70)
(37.31)
(45.64)
(70.25)
(75.01)
A (mm)
3-1/8˝ (79.38)
3-19/64˝ (83.74)
4-11/32˝ (110.33)
4-9/64˝ (105.17)
4-7/16˝ (112.71)
5-23/64˝ (136.13)
B (mm)
2-47/64˝ (69.45)
3-7/32˝ (81.76)
3-43/64˝ (93.27)
3-25/64˝ (86.1)
4-43/64˝ (118.67)
5-21/64˝ (135.33)
C (mm)
2-45/64˝ (68.66)
2-53/64˝ (71.83)
3-1/2˝ (88.9)
2-45/64˝ (68.66)
2-53/64˝ (71.83)
3-1/2˝ (88.9)
D (mm)
1-37/64˝ (40.08)
1-55/64˝ (47.23)
2-17/32˝ (64.29)
2-39/64˝ (66.28)
3˝ (76.20)
3-35/64˝ (90.09)
E (mm)
1-15/64˝
1-31/64˝
1-15/32˝
1-51/64˝
2-49/64˝
2-61/64˝
(31.35)
(37.70)
(37.31)
(45.64)
(70.25)
(75.01)
F (mm)
2-5/32˝ (54.77)
2-11/32˝ (59.53)
2-3/8˝ (60.33)
2-11/64˝ (55.17)
2-23/64˝ (59.93)
2-3/8˝ (60.33)
Operating Principle
The valve is divided into two chambers by a diaphragm. These upper and lower chambers are connected by a small air passage so both chambers see the same pressure.
When the exhaust is closed air cannot vent out of the upper chamber and the valve stays closed as shown in Figure 1. When the exhaust on the upper chamber is opened
the air pressure decreases on top of the diaphragm allowing the air pressure on the bottom to force open the valve by pushing the diaphragm up as shown in Figure 2. When
the valve opens an abrupt air blast comes through the valve outlet and is directed by the dust collector to the dirty filter. The air pulse then blows out through the filter from the
inside blowing the particulate accumulation off of the filter to clean it. After the air pulse the pressure in the upper and lower chamber will equalize and the diaphragm will return
to the closed position. The valve exhaust port is controlled by either an integral or remote solenoid.
EXHAUST
DIAPHRAGM
AIR INLET
FLOW
OUTLET
Figure 1: Closed Position
CALL TO ORDER:
U.S. Phone 219 879-8000
•
Figure 2: Open Position
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
23
024:pg2
6/6/11
3:30 PM
NPB-41
Page 1
New Products
Series
BV2FH
Two-Piece Stainless Steel Flange Ball Valve
ISO Mounting Pad, Hand Lever
Dimensions (in)
D
C
Model
BV2FH02
BV2FH03
BV2FH04
BV2FH05
BV2FH06
BV2FH07
BV2FH08
BV2FH09
BV2FH10
B
A
The Series BV2FH Two-Piece Stainless Steel Flange Ball Valve is designed to
meet ANSI B16.34 flange standards and features ANSI 150# flanged ends for easy
installation. The valve features a stem design providing additional protection against blow
outs and RTFE seats and seals for extended life. An ISO 5211 mounting pad accepts direct
mounting of pneumatic and electric actuators. All sizes allow for maximum flow rates with
minimal pressure drops. The Series BV2FH body, ends, and ball have increased
performance from the 316 SS construction.
Size
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
2-1/2˝
3˝
4˝
Model
BV2FH02
BV2FH03
BV2FH04
BV2FH05
BV2FH06
BV2FH07
BV2FH08
BV2FH09
BV2FH10
ISO
5211
F04
F04
F05
F05
F07
F07
F07
F10
F10
A
4.25
4.62
5.00
5.50
6.50
7.00
7.50
8.00
9.00
B
1.51
1.63
1.96
1.97
2.61
2.95
3.52
4.23
4.84
C
3.53
3.88
4.25
4.62
5.00
6.00
7.00
7.50
9.00
D
5.90
5.90
7.08
7.08
8.26
8.26
10.23
10.23
12.20
Weight
lb (kg)
4 (1.81)
6 (2.72)
8 (3.63)
12 (5.44)
16 (7.26)
21 (9.53)
38 (17.24)
46 (20.87)
73 (33.11)
SPECIFICATIONS
Service: Compatible liquids and gases.
Line Size: 1/2 to 4˝.
End Connection: 150# flange.
Pressure Limit: 275 psi (16 bar).
Wetted Materials:
Body and ends: CF8M;
Ball: 316 SS;
Seat: RTFE.
Temperature Limit: 450°F (232°C); 366°F (186°C) steam.
Other Materials:
Belleville washer, lock washer, handle washer, handle nut, handle,
and packing nut: 304 SS;
Thrust washer: 50% TFE and 50% SS powder;
O-ring: FKM;
Stem: ASTM;
Body seal: RTFE.
Cv
Price
15
$131.00b
40
152.00b
70
208.00b
130
257.00b
240
384.00b
400
538.00b
700
807.00b
980 1170.00b
1700 1703.00b
b Items are subject to Schedule B discounts.
Series
3BV2FH
NPT
Size
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
2-1/2˝
3˝
4˝
3-Way Stainless Steel Flange Ball Valve
Full Port, ISO Mounting Pad, Hand Lever
Dimensions (in)
Model
3BV2FHX02
3BV2FHX03
3BV2FHX04
3BV2FHX05
3BV2FHX06
3BV2FHX07
3BV2FHX08
3BV2FHX09
3BV2FHX10
D
C
B
A
The Series 3BV2FH 3-Way Stainless Steel Flange Ball Valve is designed to meet
ANSI B16.34 flange standards and features ANSI 150# flanged ends for easy installation.
This full port valve is ideal for mixing applications. An ISO 5211 mounting pad accepts
direct mounting of pneumatic and electric actuators. All sizes from 1/2 to 4˝ have excellent
flow rates with minimal pressure drops. The Series 3BV2FH has a 4-seat design for high
cycles and increases performance from high quality 316 SS ball and stem construction.
T-Port
L-Port
Model
Model
3BV2FHL02 3BV2FHT02
3BV2FHL03 3BV2FHT03
3BV2FHL04 3BV2FHT04
3BV2FHL05 3BV2FHT05
3BV2FHL06 3BV2FHT06
3BV2FHL07 3BV2FHT07
3BV2FHL08 3BV2FHT08
3BV2FHL09 3BV2FHT09
3BV2FHL10 3BV2FHT10
b Items are subject to Schedule B
Size
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
2-1/2˝
3˝
4˝
24
Cv
L-Port T-Port
16
10
24
14
45
25
77
34
100
56
430
110
670
160
1170
260
2070
430
discounts.
VISIT OUR WEBSITES:
Price
$344.00b
421.00b
548.00b
769.00b
1031.00b
1637.00b
2399.00b
3123.00b
5079.00b
www.dwyer-inst.com
NPT
Size
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
2-1/2˝
3˝
4˝
ISO
5211
F03/F04
F04/F05
F04/F05
F05/F07
F05/F07
F07/F10
F10
F10
F10
SPECIFICATIONS
Service: Compatible liquids and gases.
Line Size: 1/2 to 4˝.
End Connection: 150# flange.
Pressure Limit: 275 psi (19 bar).
Wetted Materials:
Body and ends: CF8M;
Ball and stem: 316 SS;
Stem packing: TFE;
Seats: RTFE 1/2 to 2˝; TFE 2-1/2 to
4˝.
A
5.98
6.57
7.28
7.97
8.66
9.96
11.81
12.01
14.51
B
2.26
2.72
2.93
3.78
4.07
4.78
6.16
5.37
6.16
C
5.71
6.50
7.68
8.12
9.84
12.20
19.69
25.59
25.59
•
B-C
www.dwyer-inst.co.uk
A-B
•
Weight
lb (kg)
8 (3.63)
10 (4.54)
15 (6.80)
22 (9.98)
29 (13.15)
48 (21.77)
55 (24.95)
71 (32.21)
118 (53.52)
Temperature Limit: 450°F (232°C).
Other Materials:
Packing gland, belleville washer,
gland nut, handle nut, stop pin,
handle bolt, handle, bolts and nuts:
304 SS;
Bushing: PTFE;
O-ring: FKM;
Blind cap and bonnet: CF8M;
Gasket and body seal: TFE.
Flow Path
Port
Configuration Position 1 Position 2
A-B
“T” Port
A-C
“L” Port
D
2.99
3.29
3.64
3.98
4.33
4.98
5.91
6.00
7.25
www.dwyer-inst.com.au
025:pg2
6/7/11
9:30 AM
Page 1
3-Way Stainless Steel Sanitary Ball Valve
Full Port, ISO Mounting Pad, Hand Lever
Dimensions (in)
A
Model
3BV3SHX02
3BV3SHX03
3BV3SHX04
3BV3SHX06
3BV3SHX07
3BV3SHX08
3BV3SHX09
D
C
B
The Series 3BV3SH 3-Way Stainless Steel Sanitary Ball Valve features sanitary
clamp ends allowing for easy line removal. Ideal for use in pharmaceutical, food & beverage,
and chemical processing systems. Full port design provides consistent flow characteristics.
An ISO 5211 mounting pad is provided for easy automation when attached with an electric
or pneumatic actuator. Ball and stem are constructed of quality 316 SS.
Size
1/2˝
3/4˝
1˝
1-1/2˝
2˝
2-1/2˝
3˝
L-Port
Model
3BV3SHL02
3BV3SHL03
3BV3SHL04
3BV3SHL06
3BV3SHL07
3BV3SHL08
3BV3SHL09
T-Port
Model
3BV3SHT02
3BV3SHT03
3BV3SHT04
3BV3SHT06
3BV3SHT07
3BV3SHT08
3BV3SHT09
L-Port
3.5
11
22
56
110
162
270
b Items are subject to Schedule B discounts.
Cv
T-Through T-Branched
3
5.3
9.2
16
16
33
49
85
93
160
144
315
240
410
Series
3BV3H
Price
$660.00b
737.00b
876.00b
1480.00b
2186.00b
3930.00b
5042.00b
NPT
Size
1/2˝
3/4˝
1˝
1-1/2˝
2˝
2-1/2˝
3˝
ISO
5211
F03/04
F03/04
F04/05
F05/07
F05/07
F07/10
F010/12
SPECIFICATIONS
Service: Compatible liquids and gases.
Line Size: 1/2 to 3˝.
End Connection: Sanitary clamp.
Pressure Limit: 1000 psi (69 bar).
Wetted Materials:
Body and ends: CF8M;
Ball and stem: 316 SS;
Seat: PTFE.
Temperature Limit: 450°F (232°C);
366°F (186°C) steam.
Port
Configuration
“T” Port
“L” Port
A
4.60
5.00
6.00
6.90
7.20
9.00
10.20
B
1.80
1.90
2.30
2.80
3.20
3.90
4.90
C
3.00
3.10
3.40
4.00
4.40
4.30
5.30
D
4.70
4.70
5.40
7.20
7.20
14.60
15.70
Weight
lb (kg)
3.60 (1.63)
4.30 (1.95)
6.80 (3.08)
12.60 (5.72)
21.60 (9.80)
33.70 (15.29)
56.40 (25.58)
New Products
Series
3BV3SH
NPB-41
Other Materials:
Belleville washer: 301 SS;
Gland ring, lever nut, locking
tab, handle, stop bolt, and
bolts:
304 SS;
Anti-static device and spring:
316 SS;
Joint gasket, gasket, and seal:
PTFE;
O-ring: FKM.
Flow Path
Position 1 Position 2
A-B
A-C
B-C
A-B
3-Way Stainless Steel Ball Valve
Full Port, ISO Mounting Pad, Hand Lever
Dimensions (in)
NPT
Model
Size
3BV3HX02 1/2˝
3BV3HX03 3/4˝
3BV3HX04 1˝
3BV3HX05 1-1/4˝
3BV3HX06 1-1/2˝
3BV3HX07 2˝
C
DB
ISO
5211
F03/04
F04/05
F04/05
F05/07
F05/07
F07/10
A
3.78
4.21
4.96
5.24
5.94
6.54
B
1.96
2.35
2.50
3.13
3.40
4.13
C
1.89
2.11
2.48
2.62
2.97
3.27
D
2.26
2.72
2.93
3.78
4.07
4.80
Weight
lb (kg)
3.90 (1.77)
5.65 (2.56)
8.85 (4.01)
11.90 (5.40)
18.45 (8.37)
23.25 (10.55)
A
The Series 3BV3H 3-Way Stainless Steel Ball Valve incorporates heavy duty construction with a full port design. Ball and stem are manufactured of high quality 316 SS. The
4-seat design is excellent for high cycle applications. Pneumatic and electric actuators can
be easily mounted using the ISO 5211 mounting pad. The Series 3BV3H offers 1/2 to 2˝ providing exceptional flow rates, minimizing pressure loss.
Size
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
L-Port
Model
3BV3HL02
3BV3HL03
3BV3HL04
3BV3HL05
3BV3HL06
3BV3HL07
T-Port
Model
3BV3HT02
3BV3HT03
3BV3HT04
3BV3HT05
3BV3HT06
3BV3HT07
Cv
L-Port T-Port
Price
10
16
$207.00b
14
24
249.00b
25
45
326.00b
34
77
482.00b
56
430
632.00b
110
670
991.00b
b Items are subject to Schedule B discounts.
CALL TO ORDER:
U.S. Phone 219 879-8000
SPECIFICATIONS
Service: Compatible liquids and gases.
Line Size: 1/2 to 2˝.
End Connection: Female NPT.
Pressure Limit: 1000 psi (69 bar).
Wetted Materials:
Body and ends: CF8M;
Ball and stem: 316 SS;
Seats: RTFE.
Temperature Limit: 450°F (232°C).
Port
Configuration
“T” Port
“L” Port
•
Other Materials:
Packing gland, belleville washer,
spring washer, body bolts, and
packing nut:
304 SS;
Blank cap: 316 SS;
Body seal, stem packing, and thrust
washer: PTFE.
Flow Path
Position 1 Position 2
A-B
A-C
B-C
U.K. Phone (+44) (0)1494-461707
A-B
•
Australia Phone (+61) (0) 2 4272 2055
25
026:pg2
6/7/11
New Products
NPB-41
9:32 AM
Page 1
Series
BV2IB
Bronze Ball Valve with ISO Mounting Pad
Full Port, Hand Lever
D
C
B
Dimensions (in)
NPT ISO
Model
Size 5211
BV2IB02 1/2˝ F03/04
BV2IB03 3/4˝ F03/04
F04/05
BV2IB04 1˝
BV2IB05 1-1/4˝ F04/05
BV2IB06 1-1/2˝ F05/07
F05/07
BV2IB07 2˝
A
2.50
2.50
3.15
3.58
3.96
4.84
B
1.65
1.94
2.07
2.28
2.81
3.17
C
2.81
3.08
3.21
3.41
4.19
4.55
A
The Series BV2IB Bronze Ball Valve with ISO Mounting Pad provides
an economical solution for commercial and general industrial use. Buna-N stem
O-rings and PTFE seats and seals allow for longer life and leak-free operations.
The valve’s stem design provides additional protection against blow outs. The
Series BV2IB full port is designed for minimal pressure drops with consistent
flow rates. ISO 5211 mounting pad accepts direct mounting of pneumatic and
electric actuators.
Price
Size Model
Cv
$52.00b
1/2˝
BV2IB02 13
67.00b
3/4˝
BV2IB03 27
78.00b
1˝
BV2IB04 49
1-1/4˝ BV2IB05 114 117.00b
1-1/2˝ BV2IB06 161 157.00b
2˝
BV2IB07 249 212.00b
b Items are subject to Schedule B discounts.
26
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
SPECIFICATIONS
Service: Compatible liquids and gases.
Line Size: 1/2 to 2˝.
End Connection: Female NPT.
Pressure Limit: 600 psi (41.4 bar).
Wetted Materials:
Body: Bronze;
Ball: Chrome plated brass;
Seat: PTFE.
Temperature Limit: 320°F (160°C).
Other Materials:
Packing gland: Brass;
Seat backing: EPDM;
O-ring: Buna-N;
Mounting pad: Bronze;
Stem packing and seal: PTFE;
Stem: Brass.
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
D
4.92
4.92
5.51
5.51
6.89
6.89
Weight
lb (kg)
0.68 (0.31)
0.78 (0.35)
0.82 (0.37)
0.91 (0.41)
1.35 (0.61)
2.22 (1.01)
027:pg2
6/7/11
9:33 AM
Page 1
SS Ball Valve with ISO Mounting Pad
Full Port, Hand Lever
Dimensions (in)
NPT
Model
Size
BV2IM00 1/4˝
BV2IM01 3/8˝
BV2IM02 1/2˝
BV2IM03 3/4˝
BV2IM04 1˝
BV2IM05 1-1/4˝
BV2IM06 1-1/2˝
BV2IM07 2˝
BV2IM08 2-1/2˝
BV2IM09 3˝
B
A
The Series BV2IM SS Ball Valve with ISO Mounting Pad provides an
economical, high quality stainless steel ball valve with an ISO mounting pad. The
ISO 5211 mounting pad accepts direct mounting of pneumatic and electric
actuators. The Series BV2IM body, ends, ball, and stem are made from high
quality 316 SS. The valve offers a stem design providing additional protection
against blow outs. Full port design allows for maximum flow rates with minimal
pressure drops.
Price
$51.00b
51.00b
51.00b
63.00b
91.00b
117.00b
175.00b
270.00b
663.00b
793.00b
b Items are subject to Schedule B discounts.
Size
1/4˝
3/8˝
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
2-1/2˝
3˝
Model
BV2IM00
BV2IM01
BV2IM02
BV2IM03
BV2IM04
BV2IM05
BV2IM06
BV2IM07
BV2IM08
BV2IM09
Cv
10
12
15
38
65
118
195
320
386
600
CALL TO ORDER:
U.S. Phone 219 879-8000
•
ISO
5211
F03/04
F03/04
F03/04
F03/04
F04/05
F04/05
F05/07
F05/07
F07/10
F07/10
A
2.56
2.56
2.95
3.15
3.54
4.33
4.72
5.51
7.28
8.07
B
1.69
1.69
1.64
1.74
1.99
2.19
2.59
3.14
3.20
3.67
Weight
lb (kg)
0.88 (0.40)
0.88 (0.40)
0.95 (0.43)
1.45 (0.66)
2.36 (1.07)
3.50 (1.59)
4.21 (1.91)
7.90 (3.58)
17.60 (7.98)
25.30(11.48)
New Products
Series
BV2IM
NPB-41
SPECIFICATIONS
Service: Compatible liquids and gases.
Line Size: 1/4 to 3˝.
End Connection: Female NPT.
Pressure Limit: 1000 psi (69 bar).
Wetted Materials:
Body and ends: CF8M;
Ball and stem: 316 SS;
Seat: RTFE.
Temperature Limit: 450°F (232°C); 366°F (186°C) steam.
Other Materials:
Gland nut, belleville washer, lock washer, handle nut, handle, and
packing nut: 304 SS;
Thrust washer, body seal, and stem packing: PTFE.
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
27
028:pg2
6/7/11
9:34 AM
NPB-41
Page 1
New Products
Series
3ABVH
3-Way Brass Ball Valve
ISO Mounting Pad, Hand Lever
D
Model
3ABVHX00
3ABVHX01
3ABVHX02
3ABVHX03
3ABVHX04
3ABVHX05
3ABVHX06
3ABVHX07
3ABVHX08
3ABVHX09
C
A
B
The Series 3ABVH 3-Way Brass Ball Valve offers an economical hand
lever ball valve for commercial and general industrial use. Perfect for manual
valve shut off in hot and cold water systems. The Series 3ABVH features PTFE
seats and seals for longer life and leak-free operation and a stem design
providing additional protection against blow outs. Valve body, end caps, ball, and
stem are all made of quality brass. The ISO 5211 mounting pad allows for direct
mounting of pneumatic and electric actuators.
Cv
T-Port
L-Port
Model
L-Port T-Port
Size
Model
1/4˝
3ABVHL00 3ABVHT00 3.26 3.50
3/8˝
3ABVHL01 3ABVHT01 3.50 4.08
1/2˝
3ABVHL02 3ABVHT02 4.20 5.02
3/4˝
3ABVHL03 3ABVHT03 7.00 7.70
1˝
3ABVHL04 3ABVHT04 12.83 14.24
1-1/4˝ 3ABVHL05 3ABVHT05 18.67 19.72
1-1/2˝ 3ABVHL06 3ABVHT06 29.75 30.69
2˝
3ABVHL07 3ABVHT07 43.76 44.58
2-1/2˝ 3ABVHL08 3ABVHT08 70.00 71.00
3˝
3ABVHL09 3ABVHT09 70.00 71.00
b Items are subject to Schedule B discounts.
Series
BBV-0
Price
$113.00b
113.00b
113.00b
126.00b
196.00b
294.00b
453.00b
736.00b
1302.00b
1338.00b
Dimensions (in)
NPT
Size
1/4˝
3/8˝
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
2-1/2˝
3˝
ISO
5211
F03
F03
F03
F03
F05
F05
F05
F07
F07
F07
A
2.07
2.07
2.19
2.45
2.87
3.42
3.91
4.61
5.54
5.74
B
2.63
2.63
2.87
3.18
3.74
4.38
4.86
5.70
6.93
7.08
C
0.93
0.93
0.93
1.01
1.20
1.42
1.91
2.31
2.56
2.76
Port
Flow Path
Configuration Position 1 Position 2
“T” Port
A-B
A-C
“L” Port
B-C
A-B
2-Valve Block Manifold
INSTRUMENT
VENT
ISOLATE
BBV-0N
The Series BBV-0 2-Valve Block Manifold is perfect for use over a broad
range of industrial applications including oil refineries, nuclear power stations,
petrochemical processing, and more. The Series BBV-0 is forged from 316
stainless steel bar stock and designed to withstand repeated open and close
operations. Suited to control oil, water, toxic fluids, chemicals, air, and steam;
the 2-valve block manifold has (1) isolate and (1) vent valves. Each valve stem is
precision machined with hard seats to reduce operating torque.
The BBV-0F and BBV-0N are designed to mount directly to industrial pressure
transmitters. The BBV-0F comes with two 7/16-20 UNF mounting bolts and one
PTFE gasket.
Model Description
BBV-0F Flanged 2-valve block manifold
BBV-0N 2-valve block manifold
28
VISIT OUR WEBSITES:
Price
$90.00
60.00
www.dwyer-inst.com
•
Weight
lb (kg)
1.16 (0.53)
1.16 (0.53)
1.21 (0.55)
1.44 (0.65)
2.64 (1.20)
4.15 (1.88)
6.02 (2.73)
9.08 (4.12)
16.33 (7.41)
19.55 (8.87)
SPECIFICATIONS
Service: Compatible liquids and gases.
Line Size: 1/4 to 3˝.
End Connection: Female NPT.
Pressure Limit: 400 psi (27.6 bar).
Wetted Materials:
Body, ends, ball (hard chrome plated), and packing nut: Brass
CW 617N UNI EN 12165;
Seat and stem seal: PTFE.
Temperature Limit: 320°F (160°C).
Other Materials:
Thrust washer: PTFE;
Stem and body o-ring: FKM;
Screw and lever handle: Plated steel;
Stem and bushing: Brass CW 617N UNI EN 12165.
Stainless Steel Body, NPT Connections
BBV-0F
D
4.72
4.72
4.72
4.72
6.69
6.69
6.69
9.05
9.05
9.05
PROCESS
SPECIFICATIONS
Service: Compatible liquids, gases, or steam.
End Connections:
Process connection: 1/2˝ female NPT;
Instrument connection:
No flange: 1/2˝ male NPT;
Flange: 1/2˝ DIN 19213 flange;
Vent/test: 1/4˝ female NPT.
Wetted Materials:
Body, stem, valve assembly: 316 SS;
Stem packing: PTFE.
Pressure Limit: 6000 psi (400 bar).
Temperature Limit: 464°F (240°C).
Other Materials: Handle: 304 SS.
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Download