OPTEVA fi 760 ADVANCED FUNCTION WALK-UP ATM THROUGH THE WALL R CALL 1-800-999-3600 CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP-820718-001. TOP FUNCTION KEY CARD READER STATEMENT PRINTER ( DI M ENSI ONS I NI NCHES) ADVANCED FUNCTION DISPENSER 794 TOP FUNCTION KEY (3114") 13 768 13 1 ( 2") (3014") 1 ( 2") 193 1197 CAE ( 2738" ) 695 SAFE 1038 ADA 82 ADVANCED FUNCTION DISPENSER STATEMENT PRINTER 1 (47 8") 9 16") (7 1000 (3938") (40 4") 152 (6") (40 4") 1022 193 1219 9 16") (48") (7 1000 152 (6") (3938") 1 152 (6") 1022 1 43 851 (3312") 11 16") (1 207 873 43 (818") (3438") (11116") 1247 193 1050 152 1050 207 901 43 (4918") (7916") (4138") (6") (4138") (818") (35 2") 1 (11116") HEIGHT - FROM SIDEWALK LEVEL 102 (314") CARD READER HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH CSA ( 4078" ) DI M ENSI ONS I N MI LLI M ETRES L549 5 HIGH WITH 13mm 1 (2") SAFE DEPTH - FROM FRONT EDGE OF BEZEL (4") 610 W.O. WALL OPENING HEIGHT NOTE #1: (24") 766mm (3018") MAXIMUM HEIGHT FROM EXTERIOR SIDEWALK / FLOOR LEVEL TO 343 ( 1312" ) THI RD ANGLE PROJECTI ON CSA BOTTOM OF WALL OPENING FOR CANADIAN STANDARDS ASSOCIATION (CSA) REQUIREMENTS. INSIDE FLOOR LEVEL CANNOT EXCEED 54mm (218") ABOVE EXTERIOR SIDEWALK / FLOOR LEVEL AND STILL COMPLY WITH THESE STANDARDS 788mm (31") MAXIMUM HEIGHT FROM EXTERIOR SIDEWALK / FLOOR LEVEL TO ADA BOTTOM OF WALL OPENING FOR AMERICANS WITH DISABILITIES ACT (ADA) 61 ( 238" ) REQUIREMENTS. INSIDE FLOOR LEVEL CANNOT EXCEED 76mm (3") ABOVE 31 EXTERIOR SIDEWALK / FLOOR LEVEL AND STILL COMPLY WITH THESE STANDARDS 610 W.O. 31 (24") (1316") 817mm (3218") MAXIMUM HEIGHT FROM EXTERIOR SIDEWALK / FLOOR LEVEL TO 672 FASCIA 3 16") (1 BOTTOM OF WALL OPENING FOR CENTRE FOR ENVIRONMENTS (CAE) CAE (2638") REQUIREMENTS. INSIDE FLOOR LEVEL CANNOT EXCEED 105mm (418") ABOVE EXTERIOR SIDEWALK / FLOOR LEVEL AND STILL COMPLY WITH THESE STANDARDS PLAN VIEW FOR ALL THREE STANDARDS ABOVE, WHERE INSIDE FLOOR IS MORE THAN 863mm (34") BELOW THE BOTTOM OF THE WALL OPENING THE OWNER’S G.C. MUST PROVIDE A SUPPORT PLATFORM. 330mm ( 13") MAXIMUM WALL THICKNESS IN AREA OF UNIT RECOMMENDED SERVICE AREA MINIMUM SERVICE AREA AIR VENTS 254 104 ( 418" ) 79 ( 318" ) 5 ) 16" HOLD 68 (21116") 330 WALL OPENING HEIGHT NOTE #2 VERIFY INSIDE FLOOR AND EXTERIOR SIDEWALK / FLOOR LEVEL HEIGHTS PRIOR TO CONSTRUCTING WALL OPENING. IF INSIDE FLOOR LEVEL IS HIGHER OR LOWER THAN EXTERIOR SIDEWALK / FLOOR, DIMENSION FOR WALL OPENING HEIGHT MUST BE ADJUSTED ACCORDINGLY AND OPTIMUM OPERATING HEIGHTS MAY NOT BE MET. EXTERIOR ELEVATION MAX. WALL (13") HOLD 343 695 SAFE (1312") (2738") 889 MINIMUM (35") 1038 1000 RECOMMENDED (4078") (3938") VERTICAL SECTION ( 7234" ) 1848 M I NI M UM 0m m TO 152m m (0"TO 6" )LEVELI NG 7 ) 16" ( 31 799 191 (712") ( 6234" ) 1594 795 ( 31 5 ( 28 8" ) 728 W . O. 1243 ( 481516" ) ( 45" ) 1142 40 (1916") 712 235 38 ( 112" ) 51 ( 2" ) ( 914" ) TOP OF MONITOR TOP FUNCTION KEY ( 28 58" ) 728 W . O. ( 3218" ) 184 SEE WALL OPENING DETAIL FOR RECOMMENDED CLEARANCE REQUIRED AROUND FASCIA. 815 FASCI A ( 3938" ) WI TH SI GNAGE PANEL OPTIONAL CONSUMER BAR CODE SCANNER (SEE "CAUTION" LABEL) SEE PAGE 2 OF 4 ( 714" ) (118") 1000 FASCI A ( 3218" ) 815 FASCI A WI TH SI GNAGE PANEL ( 3938" ) INSTALLATION/SERVICE AREA 29 (2638") 1000 FASCI A 184 (714") ( 28" ) 672 FASCIA 330 (13") ( 10" ) 63 (2716") SEE W ALL OPENI NG HEI GHT NOTES #1 & #2 FI LE NO.177460 REV.12 " ALL DI M ENSI ONS AND DESI GN CRI TERI A SUBJECT TO CHANGE W I THOUT NOTI CE" PAGE 1 OF 4 OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL CONDUIT AND JUNCTION BOX REQUIREMENTS 1 POWER REQUIREMENTS THE ATM REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND IS NOT ACCEPTABLE). THE ATM WILL PROVIDE A POWER CORD WITH A COUNTRY 25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO 102mm (4") SQ. X 54mm (218") SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW. DP. JUNCTION BOX (ALL BY OWNER’S E.C.) DIEBOLD 100-127 VAC (+6%, -10%) 50Hz (– 1%) SINGLE-PHASE TO PROVIDE FLAT COVER WITH TAMPER SWITCH. 100-127 VAC (+6%, -10%) 60Hz (– 1%) SINGLE-PHASE 2 WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED 200-240 VAC (–10%) 50Hz (– 1%) SINGLE-PHASE TO ATM UNIT, OWNER’S E.C. TO RUN 19mm 3 (4") METAL CONDUIT FROM 200-240 VAC (–10%) 60Hz (– 1%) SINGLE-PHASE 102mm (4") SQ. X 54mm (218") DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY. 3 OWNER’S E.C. TO RUN 19mm 3 (4") LIQUID TIGHT FLEX METAL CONDUIT OR 19mm POWER TO THE ATM IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A 3 (4") SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE. CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE. ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES 4 3 19mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102mm (4") SQ. 100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES X 54mm (218") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2184mm (86") OF 200-240 VAC (–10%) SERVICE, DISCONNECT AT 10 AMPERES SIDE CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE ACCORDINGLY (ALL BY OWNER’S E.C.) (SEE POWER REQUIREMENTS). POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11. 5 OWNER’S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2184mm (86") POWER USAGE FROM SIDE OF UNIT. 1 MACHINE STATUS IDLE (NO TRANSACTION) NOTE: OR BULK NOTE) IN PROGRESS PLATE. ( LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). RAPID PROCESSING LOCATE IN AN EASILY ACCESSIBLE AREA. TRANSACTION IN PROGRESS 2 HEATER 2 WITH HEATER 190 WATTS 690 WATTS 255 WATTS 755 WATTS 285 WATTS 785 WATTS 375 WATTS 875 WATTS 550 WATTS 1,050 WATTS 640 WATTS 1,140 WATTS TRANSACTION (DISPENSE JUNCTION BOXES MUST BE LOCATED WITHIN 2184mm ( 86") OF CONNECTING WITH 1 BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED CONFIGURATION WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. PROCESSOR, COLOR LCD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL 1 PRINTER, 80mm THERMAL RECEIPT PRINTER, STANDARD DEPOSITORY AND 5 HIGH AFD. PHYSICAL SECURITY 2 THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295, PROCESSOR, SVD LCD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL PRINTER, 80mm THERMAL RECEIPT PRINTER, IDM, 5 HIGH AFD, SIGNAGE AND BULK NOTE ACCEPTOR. 12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE DOOR RAPID PROCESSING - SYSTEMS CONFIGURED FOR SIMULTANEOUS IDM (INTELLIGENT HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR SHOULD BE CONTROLLED DEPOSITORY MODULE) AND ENA (ENHANCED NOTE ACCEPTOR) OR IDM AND BNA (BULK BY A MINIMUM OF A GROUP 2M UL LISTED COMBINATION LOCK WITH OR WITHOUT NOTE ACCEPTOR) OPERATIONS. KEYLOCKING DIAL CAPABILITY OR OPTIONAL ELECTRONIC LOCK. THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE ATM, AND THE TYPE OF TRANSACTION THE ATM IS PERFORMING. ALARM PROTECTION THE UL-LISTED SAFE IS EQUIPPED WITH A BASIC ALARM SENSOR PACKAGE. THE BASIC PACKAGE INCLUDES A SAFE DOOR OPEN SWITCH, ALARM SHUNTING SWITCH, PROJECTI ON 1 2,677 BTU/HR DISPENSE WITH HEATER 648 BTU/HR IDLE WITHOUT HEATER 3,580 BTU/HR RAPID PROCESSING WITH HEATER 2 2,984 BTU/HR BULK NOTE WITH HEATER 870 BTU/HR IDLE WITHOUT HEATER 3,890 BTU/HR RAPID PROCESSING WITH HEATER. BUILDING AIR PRESSURE BUILDING AIR PRESSURE DIFFERENCES AT THE ATM INSTALLATION LOCATION AFFECT THE INFILTRATION OF OUTSIDE AIR AND ACCOMPANY DIRT. THE ATM WILL OPERATE THROUGH ITS FULL RANGE OF FASCIA TEMPERATURES -34” C TO 54” C (-29” F TO 129” F) WITH ZERO (STATIC) OR POSITIVE AIR PRESSURE DIFFERENTIAL OPERATING ENVIRONMENT (MEASURED FROM THE INSIDE TO THE OUTSIDE OF THE BUILDING AT THE ATM 10” C TO 38” C (50” F TO 100” F) SAFE LOCATION INSTALLATION LOCATION). IF STATIC OR POSITIVE AIR PRESSURE CANNOT BE RELATIVE HUMIDITY ( NON-CONDENSING ) MAINTAINED, THE FASCIA LOWER LIMIT TEMPERATURE IS -20” C (-4” F). THE 20 TO 80% AT 32” C (90” F), MAXIMUM NEGATIVE AIR PRESSURE ALLOWED IS 0.05" H O. 2 20 TO 55% AT 38” C (100” F) -34” C TO 54” C (-30” F TO 130” F) RELATIVE HUMIDITY 15 TO 100% FASCIA LOCATION SIGNAL CABLE RUN CONSTRAINTS THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. WEIGHT OF UNIT 696kg (1,535 LBS.) SEPARATION FROM OTHER CABLES BELOW 2 KVA 2-5 KVA ABOVE 5 KVA 127mm (5") 127mm (5") 127mm (5") UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT 127mm (5") 305mm (12") UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT 64mm (212") 152mm (6") 30mm (1316") 76mm (3") TYPE OF ELECTRICAL RUN FLUORESCENT, NEON OR INCANDESCENT LIGHTING FIXTURES POWER LINES IN GROUNDED CONDUIT WITH SIGNAL CABLES IN GROUNDED CONDUIT 305mm (12") 152mm (6") SIGNAL CABLE INSTALLATION CONSTRAINTS RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS. UNLIKE POWER AND 1594 64 51 (212") (2") ( 6234" ) 0m m TO 152m m (0"TO 6" )LEVELI NG (2634") 104 80 1 4 180 330 (718") (13") ( 318" ) 40 AIR VENTS ( 418" ) 19 WITHSTAND AS MUCH STRAIN IN INSTALLATION. 3 ( ) 4" LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT 679 " ALL DI M ENSI ONS AND DESI GN CRI TERI A SUBJECT TO CHANGE W I THOUT NOTI CE" CAUTION LABEL 610mm (2’-0") ( 1916" ) PAGE 2 OF 4 WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT FI LE NO.177460 REV.12 THI RD ANGLE AND RATE-OF-RISE HEAT SENSOR. HEAT OUTPUT CONFIGURATION AIR VENTS 2 4 1 5 3 149 508 343 (578") (20") (1312") 38 (112") 1038 (4078") INTERIOR ELEVATION VERTICAL SECTION OPTEVAfi 760 ADVANCED FUNCTION WALK-UP ATM THROUGH THE WALL R 5 HIGH WITH 13mm 1 (2") SAFE CALL 1-800-999-3600 WALL OPENING DETAIL SUPPORT PLATFORM AS REQUIRED (NOT BY DIEBOLD) NOTCH REQUIRED IN WALLS 610 W.O. OVER 191mm (712") (24") ( 2858" ) ( 2858" ) 728 W . O. 82 191 101 1 (7 2") (4") 610 W.O. 3 INTERIOR FLOOR LEVEL OR TOP OF SUPPORT PLATFORM BY THE OWNER’S G.C. 610 W.O. 712m m ( 28" )M I N. 350 (13 4") 863m m ( 34" )M AX. SEE W ALL OPENI NG HEI GHT NOTES #1 & #2 142 (24") ( 558" ) MAX. 142 ( 43" ) (314") ( 558" ) 1092 SHOW N 728 W . O. (3314") ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES 845 SHOWN PROJECTI ON PLAN VIEW INTERIOR ELEVATION 330 MAX. WALL IN AREA OF UNIT (13") DETAIL FOR WALLS OVER 191mm ( 712") SECTION WALL OPENING HEIGHT NOTE #1: 766mm 330mm (13") MAX. WALL THICKNESS IN AREA OF UNIT CSA (3018") MAXIMUM HEIGHT FROM EXTERIOR SIDEWALK / FLOOR LEVEL TO BOTTOM OF WALL OPENING FOR CANADIAN STANDARDS ASSOCIATION (CSA) REQUIREMENTS. INSIDE FLOOR LEVEL CANNOT EXCEED 54mm (218") ABOVE EXTERIOR SIDEWALK / FLOOR LEVEL AND STILL COMPLY WITH THESE STANDARDS 788mm (31") MAXIMUM HEIGHT FROM EXTERIOR SIDEWALK / FLOOR LEVEL TO ADA BOTTOM OF WALL OPENING FOR AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS. INSIDE FLOOR LEVEL CANNOT EXCEED 76mm (3") ABOVE EXTERIOR SIDEWALK / FLOOR LEVEL AND STILL COMPLY WITH THESE STANDARDS 817mm (3218") MAXIMUM HEIGHT FROM EXTERIOR SIDEWALK / FLOOR LEVEL TO BOTTOM OF WALL OPENING FOR CENTRE FOR ENVIRONMENTS (CAE) CAE PAGE 3 OF 4 * FOR ALL THREE STANDARDS ABOVE, WHERE INSIDE FLOOR IS MORE THAN 863mm (34") BELOW THE BOTTOM OF THE WALL OPENING THE OWNER’S G.C. MUST PROVIDE A SUPPORT PLATFORM. OPENING FOR PROPER INSTALLATION OF THE ATM *724 1 (28 2") 610 W.O. *57 (214") 0 (24") LINE OF FASCIA WITH SIGNAGE PANEL LINE OF FASCIA 728 W . O. ( 28 58" ) ( 2858" ) 728 W . O, 1 870 ( 34 4" ) ( 2858" ) 728 W . O. 712m m ( 28" )M I N. OPENING FOR PROPER INSTALLATION OF ATM 863m m ( 34" )M AX. *CLEARANCE REQUIRED AROUND WALL WALL OPENING HEIGHT NOTE #2 SEE W ALL OPENI NG HEI GHT NOTES #1 & #2 * * SEE W ALL OPENI NG HEI GHT NOTES #1 & #2 65 * ( 3" ) 77 1054 * ( 212" ) * ( 1014" ) 259 (214") 0 *57 ( 4112" ) " ALL DI M ENSI ONS AND DESI GN CRI TERI A SUBJECT TO CHANGE W I THOUT NOTI CE" REQUIREMENTS. INSIDE FLOOR LEVEL CANNOT EXCEED 105mm (418") ABOVE EXTERIOR SIDEWALK / FLOOR LEVEL AND STILL COMPLY WITH THESE STANDARDS PROVIDE VERTICAL AND HORIZONTAL FLAT PLUMB SURFACE AROUND WALL FI LE NO.177460 REV.12 THI RD ANGLE (24") 191 (712") MAX. 330 VERIFY INSIDE FLOOR AND EXTERIOR SIDEWALK / FLOOR LEVEL HEIGHTS PRIOR TO CONSTRUCTING WALL OPENING. IF INSIDE FLOOR LEVEL IS HIGHER OR LOWER THAN EXTERIOR SIDEWALK / FLOOR, DIMENSION FOR WALL OPENING HEIGHT MUST BE ADJUSTED ACCORDINGLY AND OPTIMUM OPERATING HEIGHTS MAY NOT BE MET. EXTERIOR ELEVATION MAX. WALL (13") VERTICAL SECTION FLOOR LEVEL OR TOP OF SUPPORT PLATFORM BY THE OWNER’S G.C. ANCHOR BOLT RECOMMENDED ANCHOR BOLT SIZE - M20 19mm 3 (4") (NOT SUPPLIED WITH ATM). 768 SAFE CABLE ENTRY (3014") 35 698 35 (138") (2712") (138") 465 303 (18516") (111516") ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES ENTERING THE ATM PASS THROUGH THE POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN ENTER FROM THE SIDE OR OPTIONALLY FROM UNDER THE ATM. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE OF THE SAFE AS VIEWED FROM THE REAR OF THE ATM. 417 7 ( 3 8" ) 99 222 29mm (118") DIA. HOLE FOR ALARM CABLES (SIDE ENTRY) ( 2738" ) 9 ) 16" 695 SAFE ( 1534" ) 400 AND DATA CABLES (SIDE ENTRY) 73 7 1 2 99 1 2 ( 278" ) 38 OPENING FOR POWER CORD POWER CABLE PLATE ( 112" ) 508 497 2 ( 19 2 ( 3 8" ) 38 ( 112" ) SEE CABLE ENTRY NOTE PROJECTI ON PLAN/SECTION SAFE FLOOR 1 9 (4) 14mm ( 16") DIA. LEVELING LEG HOLES 2 (4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES NOTE: RECOMMENDED SERVICE AREA SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS. 1604 MINIMUM SERVICE AREA ALL ELECTRICAL AND DATA CABLES MUST ENTER UNIT IN THIS AREA 1 16") (63 1303 453 152 794 357 (6") (3114") (14") 13 16") (17 ( 434" ) ( 6" ) 3 121 152 1000 ( 39 8" ) 7 709 ( 27 8" ) 330 ( 13" ) (6") M AX. W ALL 330 PLAN VIEW MINIMUM SERVICE AREA ( 13" ) 51 (2") W ALL 51 (2") M AX. (14") 1 ( 6" ) 2039 121 ( 434" ) 152 152 ( 2778" ) ( 13" ) 357 1 TOP CHASSIS SERVICE DOOR ( 80 4" ) TOP CHASSIS SERVICE DOOR ( 35" ) 889 708 330 1927 794 (31 4") CHEST DOOR CHEST DOOR ( 7578" ) " ALL DI M ENSI ONS AND DESI GN CRI TERI A SUBJECT TO CHANGE W I THOUT NOTI CE" PAGE 4 OF 4 (5114") FI LE NO.177460 REV.12 THI RD ANGLE 1 ( 834" ) 149 ( 578" ) 1 ( 20" ) ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES (16716") PLAN VIEW RECOMMENDED SERVICE AREA