RENOIR II Cat. Nos. AWRMG, AWSMG, AWSMT, AWWMG, AWWMT Environmental Conditions: 0-40º C, 0-90% non-condensing humidity. Input Power Rating 110-277VAC, 60Hz only (incandescent non-neutral model is 120V input only) PK-93824-10-00-2A-X2 INSTALLATION WARNINGS AND CAUTIONS: • TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS. • IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN. • DO NOT GANG VERTICALLY. • ONLY INSTALL FOR THE ALLOWED LOAD TYPES (SEE FIGURE 5). INSTALLATION FOR ANY OTHER LOAD TYPE WILL VOID WARRANTY AND POSSIBLY CAUSE DAMAGE TO THIS DEVICE AND/OR CONNECTED EQUIPMENT. • USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY. Features and Operation: • Turn Dimmer ON or OFF – Pressing the switch will turn the dimmer ON if the dimmer is OFF. If the dimmer is ON, pressing the switch will turn the dimmer OFF. • Set Dimmer Level – Adjust the knob or slider to set the desired output level. When the dimmer turns ON, the dimmer always turns ON to the level set by the slider or knob. • Set Cutoff Level – The cutoff level is the lowest voltage the dimmer will output before shutting off. To set the cutoff level, adjust the knob or slider to the cutoff level you desire, then push and hold the button for 5 seconds. The dimmer will turn OFF and then back ON again indicating that the new cutoff level has been set. To reset the cutoff level to 0, lower the slider all the way down, then push and hold the button for 5 seconds. If your load type is flickering , not turning on, or suffering from any other erratic behavior at the minimum setting, raising the cutoff level may eliminate the problem. • Preset Operation – While dimmer is off, set level of dimmer. Then press button. The dimmer will turn on at the set level. • Power Restore – Upon restoration of power, the dimmer turns ON to the state it was in at the time of power loss. • 5-Way Operation – Link together 2, 3, 4, or 5 dimmers for multi-way dimming. • LED Locator – At the bottom of the switch is an LED locator. This locator illuminates when the dimmer is OFF so you can find the dimmer in the dark. • Remote Control – If you are using a remote, the operation at the remote is identical to the operation at the master. A slight reaction delay may be noticed if operating level changes very quickly. • Service Switch – Some units have a service switch which must be used to disconnect the load when replacing lamps. The breaker should be disconnected when performing any luminaire, ballast, or other circuit service other than lamp replacement. Load Disconnected Load Connected Load Connected Load Disconnected Service Switch Service Switch Rotate far left for OFF, rotate far right for ON Installation Instructions: 1. WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING! 2. Remove existing wall plate and switch, if applicable. 3. Remove 5/8” (1.6 cm) of insulation from each circuit conductor. Make sure the ends of wires are straight. 4. Connect wires per WIRING DIAGRAM on device as follows: Twist strands of each lead tightly together and, with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise making sure no bare conductors show below the wire connectors. Secure each connector with electrical tape. 5. Installation may now be completed by carefully positioning all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting screws supplied. Snap faceplate into place. 6. Install device control push button and control assembly (see below). 7. Restore power at circuit breaker or fuse. Installation is complete. 8. Test Dimmer operation. Align flats when installing knob Load after Remote Dimmer/Switch and Master Dimmer/Switch Load White Neutral (White) – Run a separate neutral wire for each dimming circuit Load NOT X– DO share neutral wires White Hot Hot Dimmed Hot Ground Ground Traveler Ground Neutral Center tab in opening Neutral Fin break off points LOAD Neutral Remote Dimmer/Switch Master Dimmer/Switch Load in between Master Dimmer/Switch and Remote Dimmer/Switch Hot Neutral Ground Traveler Rotary dimmer Slide dimmer Hot Dimmed Hot Ground Ground Neutral Neutral LOAD Multi-Gang Installations: A multi-ganged installation exists when multiple devices are installed in the same back box. In multi-gang installations, the following may be required: 1. Dimmer location 2. Dimmer de-rating 3. Fin removal 4. Back box size 5. Use of joiner bars for adjacent dimmers. 6. Narrow dimmers must always be installed in between wide dimmers. NOTE: TEST FIT DIMMER INSTALLATION WITH THE WALL PLATE PRIOR TO BREAKING FINS OR INSTALLING DIMMERS TO ENSURE YOU UNDERSTAND ALL REQUIREMENTS. Number & Type of NARROW Slide Dimmer • These devices are designed for installation into a 2" x 3" (5.08 cm x 7.62 cm) single gang or multi-gang device back box. 2-1/2" (6.35 cm) or deeper back boxes are required. These devices are not designed for a multi-gang field configured box. In some installations where conduit entry is from the side, or, in multi-gang installations where nipples between two adjacent boxes are used, deeper back boxes may be necessary. Test fit installation prior to rough-in. • Installation of multiple devices into a single box may require de-rating and other specific installation provisions. Reference Multi-Gang Installations for more details. • As dimmers vent top/bottom, dimmers should not be installed vertically (one over the other). • To avoid flickering, flashing, or lights on one dimmer adjusting when another dimmer’s level is changed, do not share neutrals. Run separate neutrals for each load circuit back to the dimmer. Neutral (White) Break off these fins Figure 2 - Fin Removal The Renoir II product line supports up to 5-way dimming. Any combination of Dimmers, Switches, or Remotes are supported with a MAXIMUM OF 5 DEVICES. Total run length from end to end is MAXIMUM 250 FEET. Remotes require Uncontrolled Hot, Neutral, & Ground for proper operation. One traveler wire is to run in between all masters and remotes. Remotes draw 15mA power (ea) from the Dimmer to which they are connected. NOTE: Remote Hot/Neutral should ideally be fed from the same circuit as the Master. If this is not possible, ensure that the master and remote are both fed from the same phase. Master Dimmer/Switch DO NOT Break off these fins Dimmed Hot Neutral 0 0 Backbox - # Gangs Wallplate Part # 1 Device Configuration Wallplate Part # Backbox - # Gangs 2 Device Configuration Wallplate Part # 3 Backbox - # Gangs Device Configuration Wallplate Part # Number & Type of WIDE 1 Device Configuration Backbox - # Gangs 1 1 2 3 4 6** W W+W W+W+W AWP0F-01x AWP0F-02x AWP0F-03x 3 5 or 6 8 N W+N W+N+W W+W+N+W AWP0F-10x AWP0F-11x AWP0F-12x AWP0F-13x 2 4 6 8 N*+*N W+N*+*N W+N*+*N+W W*+*W+N*+*N+W AWP00-20x AWP00-21x AWP00-22x AWP00-23x 4** 6** 7 Ground W+N+N+N W+N*+N*+*N+W W*+*W+N*+N*+*N+W AWP00-30x AWP00-31x AWP00-32x AWP00-33x 1. Find the cells that correspond to your application by identifying the row with the number of wide heatsink dimmers you have, and the columns that correspond to the number of narrow heat sink dimmers you have. In the cell you’ll find the following: 2. The number indicates the number of “Gangs” required. 3. The letters under the number indicate the order dimmers should be installed, N=narrow, W=wide. 4. -W* = right fin break-off on wide dimmer, N* = right fin break-off on narrow dimmer. -*W = left fin break-off on wide dimmer, *N = left fin break-off on narrow dimmer. -*W* = fin break-off on both sides of wide dimmer, *N* = fin break-off on both sides of narrow dimmer. 5. '** indicates that use of jumper bars is required. Jumper bars can be found in the kit with the faceplate. 6. Replace 'x' in the faceplate part number with the desired color: W=White, I=Ivory, A=Almond, T=Light Almond, E=Black, G=Gray, K=24K Gold, L=Satin Stainless, R=Antique Bronze, B=Brushed Brass. NOTE: Metal finishes are not available on custom face plates. Fin Removal: Narrow/Narrow When it is desired to install dimmers in as small a space as possible, all inside fins of like sized, adjacent dimmers can be broken off. Figures 1 & 2 show how to break off fins and the specific order in which multiple dimmers must be installed in multi-gang installations. LOAD Hot Hot Hot Hot Hot Ground Ground Ground Ground Ground Neutral Joiner Bar Neutral Neutral Traveler Master Dimmer/Switch Joiner Bar Traveler Remote Dimmer/Switch Neutral Neutral Traveler Remote Dimmer/Switch Traveler Remote Dimmer/Switch Remote Dimmer/Switch Maximum 5 Devices, Dimmers or Remotes Maximum 250 feet Multiple Dimmer/Switches and Remote Dimmer/Switches 9 N+N+N Remote Dimmer/Switch Multiple Remote Dimmer/Switches Figure 3 - Joiner Bar NOTE: Basic configurations shown. For additional multi-gang configurations, see Figure 5A. Installation Requirements: Black To determine the required back-box size in multi-gang installations, reference Figure 1. In applications where the dimmers do not line up with back box device mounting holes, use joiner bars to join the dimmers together. Reference Figures 1 & 3. Multi-Way Dimming: Back Box Size Chart Rotary Dimmer Hot (Black) Back Box Size & Joiner Bars: Break off these fins Basic Configurations Hot (Black) When fins are broken, some dimmer models must be de-rated. Reference Figure 5 to determine the dimmer ratings when 0, 1, or 2 fins are removed. Back view of dimmers shown Figure 1 Black De-ratings: Dimmed Hot Neutral Ground Wide/Narrow Dimmed Hot LOAD Neutral Ground LOAD Wide/Wide Hot Hot Hot Hot Hot Ground Ground Ground Ground Ground Neutral Figure 4 - Second Single Gang Device Box Four-gang wallbox Single-gang wallbox Neutral Traveler Master Dimmer/Switch 3-1/2" deep back box is required Neutral Traveler Remote Dimmer/Switch Neutral Neutral Traveler Dimmer/Switch Traveler Remote Dimmer/Switch Maximum 5 Devices, Dimmers or Remotes Maximum 250 feet 3/4" space (use chase nipple) Remote Dimmer/Switch Figure 5 - Model, Voltage, Allowed Loads, Current and De-rating Charts INCANDESCENT DIMMER - 110-277VAC/VCA, 60Hz INCANDESCENT NON-NEUTRAL” DIMMER - 110-277VAC/VCA, 60HZ FLUORESCENT - 2 WIRE PHASE CONTROL - 120-277VAC/VCA, 60HZ ELECTRONIC LOW VOLTAGE - 120-277VAC/VCA, 60HZ Use only for permanently installed luminaire of load type: Incandescent, Tungsten, Inductive Transformer (ex: magnetic low voltage), LED fixtures with drivers with incandescent control input. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a fluorescent lighting luminaire. Use only for permanently installed luminaire of load type: Incandescent, Tungsten, Inductive Transformer (ex: magnetic low voltage), LED fixtures with drivers with incandescent control input. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a fluorescent lighting luminaire. Use only for control of electronic ballasted luminaires. Intended for Advance Mark 10, Lutron Tu-Wire, or Sylvania Quicktronic Power Sense ballasts. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a transformer supplied appliance. Use only for permanently installed luminaire of load type: Incandescent, Tungsten, or Electronic Transformer. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a fluorescent lighting luminaire. INCANDESCENT AWRMG-MA_ AWSMG-MA_ AWSMT-MA_ AWRMG-MB_ AWSMG-MB_ AWRMG-MC_ AWSMG-MC_ AWRMG-MD_ AWSMG-MD_ AWSMT-MB_ AWSMT-MC_ AWSMT-MD_ Amps VA @ 120V 0 FINS REMOVED VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V 1 FIN REMOVED 5.0 600 12.5 1500 3680 4432 8.3 1000 1917 2308 12.5 1500 2875 3463 16.0 1920 3680 4432 AWRMG-IC_ AWSMG-IC_ M I L E 1495 1801 1219 1468 12.3 1476 AWRMG-ID_ AWSMG-ID_ AWSMT-IB_ 2829 3407 12.3 1476 13.5 1620 3105 3740 7.0 840 2829 3407 5.5 660 1610 1939 10.2 1224 1265 1524 8.7 1044 2346 2825 13.0 1560 AWSMT-IC_ AWSMT-ID_ 600 VA @ 120V Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V FLUORESCENT 2 WIRE PHASE CONTROL Amps AWRMG-XA_ VA @ 120V AWSMG-XA_ VA @ 230V AWSMT-XA_ VA @ 277V Amps VA @ 120V AWRMG-XB_ VA @ 230V AWSMG-XB_ 2 FINS REMOVED 8.3 1000 6.5 780 12.5 1500 16.0 1920 8.3 1000 12.5 1500 16.0 1920 5.3 636 12.3 1476 12.3 1476 5.5 660 8.7 1044 11.1 1332 13.5 1620 7.0 840 10.2 1224 13.0 1560 AWRMG-XC_ AWSMG-XC_ AWRMG-XD_ AWSMG-XD_ Use only for permanently installed electronic ballasted luminaire of fluorescent, HID, or LED load type with driver/ballast setup for 0-10Vdc sinking control. Dimmer will sink maximum 75mA. Intended for the control of Advance Mark 7, Universal Sumper Dim, Lutron TVE, Leviton Sector, or Sylvania Quicktronic Powersense ballast. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a transformer supplied appliance. FLUORESCENT 0-10VDC SINKING CONTROL Amps AWRMG-7D_ VA @ 120V AWRMT-7D_ AWSMG-7D_ VA @ 230V AWSMT-7D_ VA @ 277V 2553 3601 1 FIN REMOVED 5.0 FLUORESCENT - 0-10VDC SINKING CONTROL - 120-277VAC/VCA, 60HZ 2001 2410 11.1 1332 2990 Amps 0 FINS REMOVED Y R INA AWRMG-IB_ AWSMG-IB_ 5.3 636 PR 16.0 1920 2875 3463 INCANDESCENT NON-NEUTRAL AWRMG-IA_ AWSMG-IA_ AWSMT-IA_ 1150 1385 6.5 780 8.3 1000 1917 2308 2 FINS REMOVED 3075 0 FINS REMOVED 1 FIN REMOVED 16.0 1920 3680 4432 AWSMT-XB_ AWSMT-XC_ 2 FINS REMOVED AWSMT-XD_ 0 FINS REMOVED 1 FIN REMOVED 5.0 600 1150 1385 6.5 780 8.3 1000 1917 2308 VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V 16.0 1920 3680 4432 Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V 8.3 1000 1917 2308 12.5 1500 VA @ 230V VA @ 277V Amps VA @ 120V 2875 3463 16.0 1920 VA @ 230V VA @ 277V 3680 4432 12.5 1500 2875 3463 1495 1801 13.5 1620 3105 3740 7.0 840 1610 1939 10.2 1224 2346 2825 13.0 1560 2990 3601 2 FINS REMOVED ELECTRONIC LOW VOLTAGE Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V AWRMG-EA_ AWSMG-EA_ AWSMT-EA_ 5.3 636 AWRMG-EB_ AWSMG-EB_ 1219 1468 12.3 1476 AWSMT-EB_ 2829 3407 12.3 1476 2829 3407 0 FINS REMOVED 8.3 1000 1917 2308 8.3 1000 VA @ 230V VA @ 277V 1917 2308 1 FIN REMOVED 5.0 600 1150 1385 2 FINS REMOVED 8.2 984 1886 2271 6.8 816 7.5 900 1564 1884 1725 2078 FAN SPEED CONTROLS, FULL VARIABLE, FULL QUIET - 120-277VAC/VCA, 60HZ For use with any fan, up to 5A. For use with any quantity of ceiling paddle fans up to maximum current rating. FAN SPEED CONTROLS FULL VARIABLE, FULL QUIET Amps AWRMG-QA_ VA @ 120V AWSMG-QA_ VA @ 230V AWSMT-QA_ VA @ 277V Amps VA @ 120V AWRMG-QB_ AWSMG-QB_ VA @ 230V VA @ 277V Amps VA @ 120V AWSMT-QB_ VA @ 230V VA @ 277V 5.5 660 1265 1524 8.7 1044 2001 2410 11.1 1332 2553 3075 0 FINS REMOVED 8.3 1000 1917 2308 8.3 1000 1917 2308 1 FIN REMOVED 5.0 600 1150 1385 6.5 780 2 FINS REMOVED 5.3 636 1495 1801 7.0 840 1610 1939 1219 1468 5.5 660 1265 1524 FLUORESCENT - 3 WIRE PHASE CONTROL 120-277VAC/VCA, 60HZ 1 2 SWITCHES - 120-277VAC/VCA, 60HZ Use only for resistive, incandescent, inductive, ballast or motor load. SWITCHES Amps HP @ 120V HP @ 230V AWWMG-0D_ HP @ 277V AWWMT-0D_ FLA VA @ 120V VA @ 230V VA @ 277V 0, 1 or 2 FINS REMOVED 15.0 1HP 1.5HP 1.5HP 12.0 1800 3450 4150 3 Device Configuration 1 N/A Wallplate Part # Backbox - # Gangs Device Configuration 1 Device Configuration Wallplate Part # 3 4 4 6** 9 W W+W W+W+W W+W+W+W AWP0F-02x AWP0F-03x AWP0F-04x W*+*W W*+*W*+*W W*+*W*+*W*+*W AWP00-02x AWP00-03x AWP00-04x 5 or 6 8 not supported 1 2 AWP0F-01x Wallplate Part # Backbox - # Gangs Number & Type of WIDE 3 3 W+N+W W+W+N+W W+W+N+W+W AWP0F-10x AWP0F-11x AWP0F-12x AWP0F-13x AWP0F-14x not supported Device Configuration Wallplate Part # Device Configuration Wallplate Part # Backbox - # Gangs Device Configuration Wallplate Part # Backbox - # Gangs 5+1** or 7 9 W*+*W+N+W W*+*W+N+W*+*W AWP00-13x AWP00-14x 10 12 1+1 3+1, or 5 W+N+N W+N+N+W W+W+N+N+W W+W+N+N+W+W AWP0F-20x AWP0F-21x AWP0F-22x AWP0F-23x AWP0F-24x N*+*N W+N*+*N W+N*+*N+W W*+*W+N*+*N+W W*+*W+N*+*N+W*+*W AWP00-20x AWP00-21x AWP00-22x AWP00-23x AWP00-24x 4** 6** 9 11 N+N 2 4 6 8 4 11 W+N 7 Additional Configurations 7 N Backbox - # Gangs Backbox - # Gangs 5 Figure 5A - continued 6 10 14 N+N+N W+N+N+N W+N+N+N+W W+W+N+N+N+W W+W+N+N+N+W+W AWP0F-30x AWP0F-31x AWP0F-32x AWP0F-33x AWP0F-34x Device Configuration 3 5 7 9 N*+*N*+*N W+N*+*N*+*N W+N*+*N*+*N+W W*+*W+N*+*N*+*N+W W*+*W+N*+*N*+*N+W+W Wallplate Part # AWP0F-30x AWP00-31x AWP00-32x AWP00-33x Device Configuration Wallplate Part # Backbox - # Gangs 11 5 Remove Fins Fins Left On Remove Fins Fins Left On Remove Fins Fins Left On 0 Backbox - # Gangs 0 Number & Type of NARROW Additional Configurations Remove Fins Fins Left On Remove Fins Fins Left On Remove Fins Fins Left On Remove Fins Fins Left On FLUORESCENT 0, 1 or 2 FINS 3 WIRE PHASE CONTROL REMOVED Amps 5.0 AWRMG-HA_ VA @ 120V 600 AWSMG-HA_ 1150 VA @ 230V AWSMT-HA_ 1385 VA @ 277V Amps 8.3 AWRMG-HB_ VA @ 120V 1000 AWSMG-HB_ 1917 AWSMT-HB_ VA @ 230V 2308 VA @ 277V Amps 12.5 AWRMG-HC_ VA @ 120V 1500 AWSMG-HC_ 2875 AWSMT-HC_ VA @ 230V VA @ 277V 3463 Amps 16.0 AWRMG-HD_ VA @ 120V 1920 AWSMG-HD_ 3680 AWSMT-HD_ VA @ 230V VA @ 277V 4432 Figure 5A Number & Type of NARROW Use only for control of electronic ballasted luminaires. Intended for Lutron Eco-10, Hi-Lume, or Hi-Lume 3D Fluorescent Ballasts. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a transformer supplied appliance. Backbox - # Gangs Device Configuration Wallplate Part # Backbox - # Gangs Device Configuration Wallplate Part # Backbox - # Gangs Number & Type of WIDE 0 1 2 3 4 4+1** 6+1** or 8 8+1** or 10 13 15 N+N+N+N W+N+N+N+N W+N+N+N+N+W W+W+N+N+N+N+W W+W+N+N+N+N+W+W AWP0F-40x AWP0F-41x AWP0F-42x AWP0F-43x AWP0F-44x N*+*N*+*N*+*N W+N*+*N*+*N*+*N W+N*+*N*+*N*+*N+W W*+*W+N*+*N*+*N*+*N+W W*+*W+N*+*N*+*N*+*N+W*+*W AWP00-40x AWP00-41x AWP00-42x AWP00-43x AWP00-44x 7** 9** 11** or 12 14 4 6 8 10 12 17 Device Configuration N+N+N+N+N W+N+N+N+N+N W+N+N+N+N+N+W W+W+N+N+N+N+N+W W+W+N+N+N+N+N+W+W Wallplate Part # AWP0F-50x AWP0F-51x AWP0F-52x AWP0F-53x AWP0F-54x 5 7 9 11 Backbox - # Gangs Device Configuration Wallplate Part # Backbox - # Gangs Device Configuration Wallplate Part # Backbox - # Gangs 13 W+N*+*N*+*N*+*N+*N+W W*+*W+N*+*N*+*N*+*N+*N+W W*+*W+N*+*N*+*N*+*N+*N+W*+*W AWP00-51x AWP00-52x AWP00-53x AWP00-54x 9+1** or 11 11+1** or 13 16 N*+*N*+*N*+*N*+*N W+N*+*N*+*N*+*N*+*N AWP00-50x 7+1** 18 N+N+N+N+N+N W+N+N+N+N+N+N W+N+N+N+N+N+N+W W+W+N+N+N+N+N+N+W W+W+N+N+N+N+N+N+W+W AWP0F-60x AWP0F-61x AWP0F-62x AWP0F-63x AWP0F-64x 6 8 10 12 14 Device Configuration N*+*N*+*N*+*N*+*N*+*N W+N*+*N*+*N*+*N*+*N*+*N W+N*+*N*+*N*+*N*+*N*+*N+W W*+*W+N*+*N*+*N*+*N*+*N*+*N+W W*+*W+N*+*N*+*N*+*N*+*N*+*N+W*+*W Wallplate Part # AWP00-60x AWP00-61x AWP00-62x AWP00-63x AWP00-64x 1.W* = right fin break-off on wide dimmer, N* = right fin break-off on narrow dimmer. *W = left fin break-off on wide dimmer, *N = left fin break-off on narrow dimmer. *W* = fin break-off on both sides of wide dimmer, *N* = fin break-off on both sides of narrow dimmer. 2. '** Indicates that use of jumper bars is required. Jumper bars can be found in the kit with the faceplate. 3. '+1 indicates that in addition to the multi-device box, a second 1 device box shall be installed 3/4" apart from the first. A 3/4" chase nipple shall be used between the two boxes (ref. Figure 4). 4. Replace 'x' in the wall plate part number with the desired color: W=White, I=Ivory, A=Almond, T=Light Almond, E=Black, G=Gray, K=24K Gold, L=Satin Stainless, R=Antique Bronze, B=Brushed Brass. NOTE: Metal finishes are not available on custom face plates. AWP00-33x LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. © 2009 Leviton Mfg. Co., Inc. For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com PK-93824-10-00-2A-X2