CBI-20 Current Loop Converter

advertisement
PROAT
CBI-20 Current Loop Converter
CBI-20 equipment adapts voltage levels from any unit of measurement (voltage divisor, direct voltage, resistive
sensor, etc) and converts to a proportional value of current loop (4-20 mA) or (0-5 mA).
It is used to distributed electric power installations (RENFE,
METRO, AVE, etc) to send away voltage values. It allows to
the control centre receives in real-time the measurement of
line voltage.
Operating features
•
•
•
•
•
•
•
Various levels (s/mod.)/ output 4…20 mA
Precision: class 0,5 CEI 688-1
Consumption < 2,5 VA
Maximum load: 500Ω
Response time: <150 ms (0 to 90% Un)
Maximum open circuit voltage: 75 VDC
Measuring range: 0 to 120% Un
Constructive features
•
•
•
•
Plastic enclosure for DIN installation
Terminals on front cover
Auxiliary voltage:(s/model):
48…120 VDC ± 20%
24 VDC ± 20%
220 VAC/50 Hz
Compliant standards:
Insulation voltage test
High frequency disturbances
Fast transitory
Voltage pulse
60
Models
45
CBI-XX Y/aaa-Z
XX = Output
Y = T. aux.
20 = 4 a 20 mA
5 = 0 a 5 mA
C = 48 a 120 VDC
B = 24 VDC
A = 230 VAC
70
48
30
aaa = Maximum voltage level.
Z = A = Alternate
C = Continuous/Direct
Example: CBI-20A/150C:
Current loop converter input 0..150 VDC and
output 4-20mA, with auxiliary supply 230 VAC
70
Warranty
1 year against manufacturing defaults.
90
Enclosure dimensions (millimeters)
CAT-001-06 (EN)
Brochure CBI-20 (160815)
PROAT
Enclosure OMEGA DIN EN 50022 (rail)
Self-extinguishing plastic material, type VO
Line Voltage
WIRING
DIAGRAM
4-20 mA
LMT
Example of installation of CBI20A/30C next to a resistive sensor CRS-3000
LMT external dimensions
Terminals CBI-20
1- Sensor voltage 9 -Output (+) current loop
3- Ground
11-Output (-) current loop
5230 VAC
7-
60
45
70
48
LMT equipment
30
It includes a secondary capacitor and the limiting element.
Terminals LMT
17.5
1 – Sensor voltage.
3 – Ground
90
Pol. Ind. Can Tapioles c/Narcís Monturiol, 4 nave 10
08110 MONTCADA-REIXAC (Barcelona) SPAIN
Tel:935790610 Fax: 935792522
e-mail: comercial@proat.es
web: www.proat.es
CAT-001-06 (EN)
Brochure CBI-20 (160815)
Download