Decoder Cable Switch Device (DCSD)TM Patent Pending Quick-disconnect Splitter – Splits the incoming signal from the central computer into two (part# 270DCSD) or three (part# 270DCSD3) directions. See wiring schematics below. By simply flipping a switch, the decoder cables can be disconnected in order to isolate sections of the system while troubleshooting. No need to cut and re-splice wires. Water Tight - Installed in valve boxes for ease of access. See installation detail below. O-Ring Seal – Provides a waterproof capsule. Cap is unscrewed to access the switches. ACME Threads – Minimizes binding of threads due to soil. 36” Leads – Allows the assembly to be brought above grade when accessing the switches for troubleshooting. Technical Data: Body Assembly Dimensions Wire Leads, 36” long Toggle Switch Rating Diameter: 2-3/16”, Height: 3-1/16” for 270DCSD Diameter: 2-3/8”, Height: 3-1/4” for 270DCSD3 3-Pairs for 270DCSD and 4-pairs for 270DCSD3, 18AWG stranded, Stripped and retained 5 Amps @ 125VAC or 28VDC, Double Pole Single Throw Typical Specifications: The Paige electric DCSD (Part# 270DCSD for 2-way split and 270DCSD3 for 3-way split) shall be installed at strategic locations of a decoder system such that it can isolate certain sections of cables for purposes of troubleshooting. The DCSD shall be installed inside an irrigation valve box as per installation detail. The splices for all connections shall be made using a 3M model DBY-6 or DBR-6 (Paige Electric Part numbers 270337 and 270338, respectively.) Installation Detail: The following installation detail can be downloaded in AutoCAD format from www.paigewire.com PAIGE ELECTRIC (DCSD) DECODER CABLE SWITCH DEVICE TOGGLE SWITCHES ISOLATING OUTGOING CABLES 3M DBY-6 OR DBR-6 DIRECT BURIAL SPLICE KITS (TYPICAL) OU TG OI NG OU TG OI NG INCO MIN GCA BL E(R ED ) CA BL E1 OUTGOING DECODER CABLES CA BL E2 (R ED ) ) CK LA E(B BL GCA MIN INCO NG OI TG OU (R ED ) E1 BL CA ) CK (BLA ) CK LA (B E2 BL CA NG OI TG OU DECODER CABLE FROM DIRECTION OF CENTRAL EQUIPMENT LOCATION. _ __ :___ :___ TO AW DR mA mA TO :___ __ _ DR AW :___ LABEL FOR DOCUMENTING NORMAL CURRENT DRAW 24" MINIMUM FROM :____ __ mA DR AW :___ FINISH GRADE NOTES: 1. INSTALL DECODER CABLE SWITCH DEVICE (DCSD) BETWEEN CABLE FROM CENTRAL AND TWO OUTGOING CABLES. 2. AT ALL SPLICE LOCATIONS, PROVIDE SUFFICIENT SLACK TO ALLOW THE SPLICE TO BE RAISED A MINIMUM OF 24" (IN.) ABOVE GRADE 3. DECODER CABLE SHALL HAVE A MINIMUM OF 24" (IN.) OF COVER. 10" ROUND VALVE BOX WITH GRAY LID 4. CLEARLY MARK ON TAG WHERE SUPPLY CABLE ORIGINATES FROM (EX: FROM 8th HOLE) AND EACH OUTGOING CABLE GOES TO (EX: TO 10th GREEN) IN AN OUTWARD BOUND DIRECTION FROM THE CENTRAL EQUIPMENT LOCATION. 5. CLEARLY MARK THE MILLIAMP DRAW FOR EACH LEG OF CABLE BASED ON THE NUMBER OF DECODERS "DOWNSTREAM" FROM THAT POINT. 3" GRAVEL (IF REQUIRED) 6" PVC SLEEVE (IF REQUIRED) NOT TO SCALE Wiring Schematics: Red Red Red s1 IN Black s1 OUT1 Black OUT1 Black Red Red s1 IN Black OUT2 Black Red Red s2 OUT2 s2 Black OUT3 Black 270DCSD 270DCSD3 CONTACT INFORMATION: LOCATION PHONE 1160 Springfield Rd, Union, NJ 07083 (800) 327-2443 14538 So. Garfield Ave., Paramount, CA 90723 (800) 228-7137 2683 W. Lake Van Ness Circle, Fresno, CA 93711 (559) 431-2346 www.paigewire.com 1/26/04 FAX (908) 687-2722 (562) 633-9532 (559) 431-2574