Type 1 & 3R Enclosures pg. 2 - 19 Section 2 Type 4 & 12 Enclosures pg. 20 - 47 Section 3 Flange Mounted Disconnect Enclosures pg. 48 - 89 Section 4 Type 4, 12 & 13 Oiltight Enclosures pg. 90 - 111 Section 5 Pushbutton Enclosures & Consolets pg. 112 - 129 Section 6 Wireways & Trough Products pg. 130 - 163 Section 7 Accessories pg. 164 - 181 Section 8 Locks & Latches pg. 182 - 185 Section 9 Index pg. 186 - 189 Index Locks & Latches Accessories Wireways & Trough Products Pushbutton Enclosures & Consolets Type 4,12 & 13 Oiltight Enclosures Flange-Mounted Disconnect Enclosures Type 4 & 12 Enclosures Section 1 Type 1 & 3R Enclosures TA B L E O F C O N T E N T S Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 1 & 3R Enclosures TYPE 1 SCREW COVER BOXES Austin screw cover boxes are Underwriters Laboratories Listed for Junction and Pull box applications. All screw cover boxes meet the general-purpose indoor requirements. Construction: Finish: • Fabricated in accordance with UL specifications from code gauge steel. Austin screw cover boxes are constructed standard in galvanized steel. An ANSI 61 gray polyester powder coating over CRS is available on request. • Boxes are furnished with or without knockouts. If knockouts are requested, a combination of 1/2 - 3/4" and 3/4 - 1" standard conduit sizes are furnished. Options: • Boxes under 48" x 36" have 5/16" mounted holes. • Special materials. • Special knockouts or knockout arrangements. • Special finishes. • Boxes 48" x 36" and over have 7/16" mounted holes. • Custom box size or construction. SEAMS ARE .31 DIA. SPOT WELDED MTG. HOLE (4 PLACES) 1.00 1.00** .500* A C B *THIS DIMENSION IS .750 WHEN "A" AND "B" ARE 24 x 24 AND OVER **THIS DIMENSION IS 1.250 WHEN "A" AND "B" ARE 24 x 24 AND OVER INDUSTRY STANDARDS UL 50 Type 1 NEMA Type 1 CUL Type 1 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 1 & 3R Enclosures SCREW COVER BOXES Catalog Number Bundle Quantity Bundle Weight Enclosure Size (AxBxC) Knockout Pattern Sides "A" Knockout Pattern Sides "B" AB-444SB AB-644SB AB-664SB AB-864SB AB-1064SB AB-1264SB AB-884SB AB-1084SB AB-1284SB AB-10104SB AB-12104SB AB-12124SB AB-15124SB AB-18124SB AB-24124SB AB-15154SB AB-18154SB AB-18184SB AB-24184SB AB-24244SB AB-30244SB AB-36244SB 5 5 5 5 5 5 5 5 5 5 5 5 1 1 1 1 1 1 1 1 1 1 10 10 15 20 22.5 25 25 25 32.5 35 40 45 11 13 15 14 16 17 23 35 43 51 4x4x4 6x4x4 6x6x4 8x6x4 10x6x4 12x6x4 8x8x4 10x8x4 12x8x4 10x10x4 12x10x4 12x12x4 15x12x4 18x12x4 24x12x4 15x15x4 18x15x4 18x18x4 24x18x4 24x24x4 30x24x4 36x24x4 A B B B B C B B C B C C C D D C D D D D D D A B B B B B B B B B B C C C C C C D D D D D AB-666SB AB-866SB AB-1266SB AB-886SB AB-1086SB AB-1286SB AB-10106SB AB-12106SB AB-12126SB AB-15126SB AB-18126SB AB-24126SB AB-15156SB AB-18156SB AB-18186SB AB-24186SB AB-24246SB AB-30246SB AB-36246SB AB-48246SB AB-30306SB AB-36306SB AB-36366SB 5 5 5 5 5 5 5 5 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 20 25 35 30 35 40 45 45 55 13 15 21 16 17 20 25 36 43 56 72 68 80 94 6x6x6 8x6x6 12x6x6 8x8x6 10x8x6 12x8x6 10x10x6 12x10x6 12x12x6 15x12x6 18x12x6 24X12X6 15X15X6 18X15X6 18x18x6 24x18x6 24x24x6 30x24x6 36x24x6 48x24x6 30x30x6 36x30x6 36x36x6 B B C B B C B C C C D D C D D D D D D D NA NA NA B B B B B B B B C C C C C C D D D D D D NA NA NA Catalog Number Bundle Quantity Bundle Weight Enclosure Size (AxBxC) Knockout Pattern (A) Sides "A" Knockout Pattern (B) Sides "B" AB-48366SB AB-48486SB 1 1 140.5 206 48x36x6 48x48x6 NA NA NA NA AB-888SB AB-10108SB AB-12128SB AB-15128SB AB-18128SB AB-24128SB AB-15158SB AB-18158SB AB-18188SB AB-24188SB AB-24248SB AB-30248SB AB-36248SB AB-48248SB AB-30308SB AB-36308SB AB-36368SB AB-48368SB AB-48488SB 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7 9.5 12 15 17 21 17 20 22.5 28 39.5 47.5 61 79 75 87 101.5 151 220 8x8x8 10x10x8 12x12x8 15x12x8 18x12x8 24x12x8 15x15x8 18x15x8 18x18x8 24x18x8 24x24x8 30x24x8 36x24x8 48x24x8 30x30x8 36x30x8 36x36x8 48x36x8 48x48x8 B B C C D D C D D D D D D D NA NA NA NA NA B B C C C C C C D D D D D D NA NA NA NA NA AB-121210SB AB-181210SB AB-181810SB AB-241810SB AB-242410SB AB-362410SB AB-303010SB AB-363010SB AB-363610SB AB-483610SB AB-484810SB 1 1 1 1 1 1 1 1 1 1 1 14 19 25 31.5 43.5 67 81 94 109 161.5 234 12x12x10 18x12x10 18x18x10 24x18x10 24x24x10 36x24x10 30x30x10 36x30x10 36x36x10 48x36x10 48x48x10 C D D D D D NA NA NA NA NA C C D D D D NA NA NA NA NA AB-121212SB AB-181212SB AB-241212SB AB-181812SB AB-241812SB AB-242412SB AB-362412SB AB-303012SB AB-363612SB AB-483612SB AB-484812SB 1 1 1 1 1 1 1 1 1 1 1 16 21 26.5 28 34.5 47.5 72 88 117 172 247.5 12x12x12 18x12x12 24x12x12 18x18x12 24x18x12 24x24x12 36x24x12 30x30x12 36x36x12 48x36x12 48x48x12 C D D D D D D NA NA NA NA C C C D D D D NA NA NA NA NOTE: Replace "SB" Suffix with: SBK: Screw Cover w/KO's SBGK: Screw Cover Gray w/KO's SBG: Screw Cover Gray "A" KNOCKOUT PATTERN 1/2"-3/4" COMBINATION POSSIBLE KNOCKOUT PAT T E R N S 1.63 "C" KNOCKOUT PATTERN 1/2"-3/4" & 3/4"-1" COMBINATION 1.69 1.63 1.69 1.69 1.69 "D" KNOCKOUT PATTERN 1/2"-3/4" & 3/4"-1" COMBINATION "B" KNOCKOUT PATTERN 1/2"-3/4" & 3/4"-1" COMBINATION 1.69 1.69 1.69 NOTE: REFER TO BOX TABLE FOR APPLICABLE KNOCKOUT PATTERN 1.63 1.69 1.69 1.69 1.69 1.63 1.69 3 Type 1 & 3R Enclosures TYPE 1 HINGED COVER BOXES Austin hinge cover boxes are Underwriters Laboratories Listed for Cabinet and Cutout box applications. All hinge cover boxes meet the general-purpose indoor requirements. Construction: Finish: • Fabricated in accordance with UL specifications from code gauge steel. Austin hinge cover boxes are constructed standard in galvanized steel. An ANSI 61 gray polyester powder coating is available on request. • Hinge cover boxes with a maximum dimension of 18" are fabricated with formed hinges and a pull ring catch. • Boxes are furnished with or without knockouts. If knockouts are requested, a combination of 1/2 " - 3/4" and 3/4" - 1" standard conduit sizes are furnished. • Back of boxes have mounting holes. INDUSTRY STANDARDS Options: • Special knockouts or knockout arrangements. • Special materials. • Special finishes. • Custom box size or construction. UL 50 Type 1 NEMA Type 1 CUL Type 1 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 1 & 3R Enclosures HINGE COVER BOXES Catalog Number Bundle Qty. Bundle Weight Enclosure Size (AxBxC) KO Pattern "A" Side KO Pattern "B" Side AB-644HC AB-664HC AB-864HC AB-1064HC AB-1264HC AB-884HC AB-1084HC AB-1284HC AB-10104HC AB-12104HC AB-12124HC AB-15124HC AB-18124HC AB-15154HC AB-18154HC AB-18184HC 5 5 5 5 5 5 5 5 5 5 5 1 1 1 1 1 10 15 20 22.5 25 25 25 32.5 35 40 45 11 13 14 16 17 6x4x4 6x6x4 8x6x4 10x6x4 12x6x4 8x8x4 10x8x4 12x8x4 10x10x4 12x10x4 12x12x4 15x12x4 18x12x4 15X15X4 18X15X4 18x18x4 B B B B C B B C B C C C D C D D B B B B B B B B B B C C C C C D AB-666HC AB-866HC AB-886HC AB-1086HC AB-1286HC AB-10106HC AB-12106HC AB-12126HC AB-15126HC AB-18126HC AB-15156HC AB-18156HC AB-18186HC 5 5 5 5 5 5 5 5 1 1 1 1 1 20 25 30 35 40 45 45 55 13 15 16 17 20 6x6x6 8x6x6 8x8x6 10x8x6 12x8x6 10x10x6 12x10x6 12x12x6 15x12x6 18x12x6 15X15X6 18X15X6 18x18x6 A B B B C B C C C D C D D A B B B B B B C C C C C D NOTE: Replace "HC" Suffix with: HCK: Hinge Cover w/KO's HCGK: Hinge Cover Gray w/KO's HCG: Hinge Cover Gray "A" KNOCKOUT PATTERN 1/2"-3/4" COMBINATION 1.63 POSSIBLE KNOCKOUT PAT T E R N S "C" KNOCKOUT PATTERN 1/2"-3/4" & 3/4"-1" COMBINATION 1.69 1.63 1.69 1.69 1.69 "D" KNOCKOUT PATTERN 1/2"-3/4" & 3/4"-1" COMBINA "B" KNOCKOUT PATTERN 1/2"-3/4" & 3/4"-1" COMBINATION 1.69 1.69 1.69 1.63 1.69 1.69 1.69 1.69 1.63 1.69 NOTE: REFER TO BOX TABLE FOR APPLICABLE KNOCKOUT PATTERN Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 5 Type 1 & 3R Enclosures TYPE 3, 12 SCREW COVER GASKETED BOXES Austin gasketed screw cover boxes are Underwriters Laboratories Listed for Wiring, Pull, Terminal, and Junction box application. They provide a degree of protection against rain, sleet, dust, dirt, external ice formation, and noncorrosive liquids. Construction: Finish: • Fabricated in accordance with UL specifications from code gauge steel. Austin gasketed screw cover boxes are constructed standard in galvanized steel. An ANSI 61 gray polyester powder coating over phosphatized surfaces is available on request. • Continuously welded seams ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. Options: • No mounting holes or mounting feet. • Special materials. • Special finishes. • Custom box size or construction. SEAMS ARE WELDED SOLID AND GROUND SMOOTH .50* A GASKET 1.00 6"MAX. 6" MAX C B * THIS DIMENSION IS .750 WHEN "A" AND "B" ARE OVER 18" INDUSTRY STANDARDS UL 50 Types 3 & 12 NEMA Types 3 & 12 (except for mounting provisions) CUL Types 3 & 0 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight AB-444GSB AB-664GSB AB-864GSB AB-884GSB AB-1084GSB AB-10104GSB AB-12104GSB AB-12124GSB 4x4x4 6x6x4 8x6x4 8x8x4 10x8x4 10x10x4 12x10x4 12x12x4 2 3 4 5 5 7 7 9 AB-666GSB AB-1266GSB AB-886GSB AB-10106GSB AB-12126GSB AB-15126GSB AB-15156GSB AB-18186GSB AB-24186GSB AB-24246GSB 6x6x6 12x6x6 8x8x6 10x10x6 12x12x6 15x12x6 15x15x6 18x18x6 24x18x6 24x24x6 4 7 6 9 11 13 16 20 26 39 Catalog Number Enclosure Size (AxBxC) Weight AB-888GSB AB-12128GSB AB-18188GSB AB-24248GSB AB-30248GSB AB-36248GSB AB-30308GSB AB-36308GSB 8x8x8 12x12x8 18x18x8 24x24x8 30x24x8 36x24x8 30x30x8 36x30x8 7 12 23 42 51 60 88 102 AB-181810GSB AB-242410GSB AB-302410GSB AB-362410GSB AB-303010GSB AB-363010GSB 18x18x10 24x24x10 30x24x10 36x24x10 30x30x10 36x30x10 25 48 58 67 96 111 AB-181812GSB AB-242412GSB AB-303012GSB AB-363612GSB 18x18x12 24x24x12 30x30x12 36x36x12 28 53 103 137 Type 1 & 3R Enclosures SCREW COVER GASKETED BOXES NOTE: Replace "GSB" Suffix with: GSBG: Gasket Screw Cover Box Gray Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 7 Type 1 & 3R Enclosures TYPE 3R RAINPROOF BOXES Austin rainproof boxes are Underwriters Laboratories Listed for Wiring or Junction box applications. All rainproof boxes are designed for outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. Construction: Finish: • Fabricated in accordance with UL specifications from code gauge steel. Austin rainproof boxes are constructed standard in galvanized steel. An ANSI 61 gray polyester powder coating over phosphatized surfaces is provided on request. • Dripshield along top of box. • Slip-on seamless cover attached by screws at bottom edge. • Embossed mounting holes on back of enclosure. Options: • Special knockouts or knockout arrangements in bottom only. • Special materials. • Special finishes. • Custom box size or construction. A .31 DIA. MTG. HOLE (4 PLACES) 1.00 .750 C 1.00 B INDUSTRY STANDARDS UL 50 Type 3R NEMA Type 3R CUL Type 3R Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 1 & 3R Enclosures RAINPROOF BOXES Catalog Number Bundle Quantity Bundle Weight Enclosure Size (AxBxC) AB-664RB AB-864RB AB-884RB AB-1084RB AB-10104RB AB-1284RB AB-12124RB 5 5 5 5 5 5 5 20 20 25 30 35 35 50 6x6x4 8x6x4 8x8x4 10x8x4 10x10x4 12x8x4 12x12x4 AB-666RB AB-886RB AB-10106RB AB-12126RB 5 5 5 5 20 30 45 60 6x6x6 8x8x6 10x10x6 12x12x6 Catalog Number Bundle Quantity Bundle Weight Enclosure Size (AxBxC) AB-15126RB AB-18126RB AB-18156RB AB-18186RB AB-24246RB 1 1 1 1 1 13 16 16 21 40 15x12x6 18x12x6 18x15x6 18x18x6 24x24x6 AB-18158RB AB-18188RB AB-24188RB AB-24248RB 1 1 1 1 20 23 35 44 18x15x8 18x18x8 24x18x8 24x24x8 1 48 24x24x10 AB-242410RB NOTE: Replace "RB" Suffix with: RBG: Rainproof Gray Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 9 Type 1 & 3R Enclosures TYPE 1 SMALL NEMA 1 O.E.M. CABINET Austin Small O.E.M. enclosures are Underwriters Laboratories Listed and designed for use as control and instrument enclosures which do not require an oil-tight or dust-tight rating. Construction: Finish: • Fabricated in accordance with UL specifications from code gauge steel. Austin Small O.E.M. enclosures are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. • Continuous hinge. • Flush latch; AB-14. • Stand-offs provided for mounting optional panel. Options: • Special materials. • Special finishes. • Custom box size or construction. CONTINUOUS HINGE AB-14 (QUARTER-TURN LATCH) .31 DIA. MTG. HOLE (4 PLACES) A .50 .50 1.18 PANEL (Optional) 1.50 C 1.18 B INDUSTRY STANDARDS UL 50 Type 1 NEMA Type 1 CUL Type 1 #10-32x.50 PRESS IN STAND-OFF FOR OPTIONAL PANEL Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog AB-664SM AB-864SM AB-884SM AB-1084SM AB-10104SM AB-12104SM AB-12124SM AB-14124SM 6x6x4 8x6x4 8x8x4 10x8x4 10x10x4 12x10x4 12x12x4 14x12x4 4 4 6 6 7 9 9 11 AB-66NP AB-86NP AB-88NP AB-108NP AB-1010NP AB-1210NP AB-1212NP AB-1412NP AB-866SM AB-886SM AB-1086SM AB-10106SM AB-12106SM AB-12126SM AB-14126SM 8x6x6 8x8x6 10x8x6 10x10x6 12x10x6 12x12x6 14x12x6 5 6 8 8 11 11 13 AB-86NP AB-88NP AB-108NP AB-1010NP AB-1210NP AB-1212NP AB-1412NP AB-12128SM AB-14128SM 12x12x8 14x12x8 13 15 AB-1212NP AB-1412NP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 1 & 3R Enclosures SMALL NEMA 1 O.E.M. CABINET 11 Type 1 & 3R Enclosures TYPE 1 LARGE NEMA 1 O.E.M. CABINET Austin Large O.E.M. enclosures are Underwriters Laboratories Listed and designed for housing electrical and electronic controls. Construction: • Fabricated in accordance with UL specifications from code gauge steel. AB-16 LATCH • Removable mounting panel. • Continuous hinge. • Enclosures have an AB-16 flush latch except as noted. Finish: Austin Large O.E.M. enclosures are provided standard with an ANSI 61 gray polyester powder coating. Panels are painted white. B-3.00 A-3.00 A .75 OMIT CENTER STUDS IF "A" IS LESS THAN 31" Options: .88 • Special materials. .88 • Special finishes. • Custom box size or construction. B FRONT VIEW w/DOOR & HINGE REMOVED C 1.00 INDUSTRY STANDARDS UL 50 Type 1 NEMA Type 1 CUL Type 1 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 1 & 3R Enclosures LARGE O.E.M. CABINET ENCLOSURES WITH PANELS Catalog Number Enclosure Size (AxBxC) Weight AB-16126LM AB-16166LM AB-20166LM AB-24166LM AB-20206LM AB-24206LM AB-24246LM AB-30246LM AB-36246LM AB-36306LM* 16x12x6 5/8 16x16x6 5/8 20x16x6 5/8 24x16x6 5/8 20x20x6 5/8 24x20x6 5/8 24x24x6 5/8 30x24x6 5/8 36x24x6 5/8 36x30x6 5/8 21 27 31 36 37 43 56 67 78 95 AB-16128LM AB-20168LM AB-20208LM AB-24208LM AB-24248LM AB-30248LM AB-36248LM AB-36308LM* 16x12x8 5/8 20x16x8 5/8 20x20x8 5/8 24x20x8 5/8 24x24x8 5/8 30x24x8 5/8 36x24x8 5/8 36x30x8 5/8 23 35 40 48 58 74 81 104 AB-242010LM AB-302410LM AB-363010LM* 24x20x10 5/8 30x24x10 5/8 36x30x10 5/8 53 81 114 AB-242412LM AB-363012LM* 24x24x12 5/8 36x30x12 5/8 69 123 *NOTE: If "A" and "B" are 36 x 30, an AB-10 tee handle is standard Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 13 Type 1 & 3R Enclosures TYPE 1 TELEPHONE CABINETS Austin Telephone Cabinets are Underwriters Laboratories Listed and are designed for use in telephone, panel junction, or cutout cabinet applications. They provide a degree of protection against limited amounts of dirt. Construction: Finish: • Fabricated in accordance with UL specifications from code gauge steel. Austin Telephone Cabinets are furnished standard with an ANSI 61 gray polyester powder coating. Box is furnished in galvanized steel. • Removable trim. • Cabinets 36" and under have an AB-16 flush locking latch. AB-16 LATCH • Cabinets 37" and over have an AB-6 three point latch handle with roller arms. • Surface or flush covers. A • Continuous hinge. Options: • Special finishes. • Custom box size or construction. • Optional Backboard studs for mounting optional Backboard. B TYPE A D+.75 D C WOOD BACKBOARD (Optional) FLUSH MOUNT INDUSTRY STANDARDS AB-6 HANDLE AB-7 w/LOCK (Optional) C WOOD BACKBOARD (Optional) SURFACE MOUNT UL 50 Type 1 NEMA Type 1 CUL Type 1 TYPE B TYPE B TELEPHONE CABINET IS AVAILABLE w/DOUBLE DOORS AND LEVER HANDLE Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 1 & 3R Enclosures TELEPHONE CABINETS A N D P LY W O O D B A C K B O A R D S Catalog Number AB-884T AB-10104T AB-12124T AB-16124T AB-18124T AB-24124T AB-18184T AB-24184T AB-30184T AB-24244T AB-30244T AB-36244T AB-30304T AB-36304T AB-48304T Type Enclosure Size (AxBxC) "D" Weight A A A A A A A A A A A A A A B 8x8x4 10x10x4 12x12x4 16x12x4 18x12x4 24x12x4 18x18x4 24x18x4 30x18x4 24x24x4 30x24x4 36x24x4 30x30x4 36x30x4 48x30x4 1 1/16" 1 1/16" 1 1/16" 1 1/16" 1 1/16" 1 1/16" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 3 1/4" 7 9 11 13 16 22 23 28 33 35 40 57 60 71 101 Backboard Catalog Number NA AB-1010TB AB-1212TB AB-1612TB AB-1812TB AB-2412TB AB-1818TB AB-2418TB AB-3018TB AB-2424TB AB-3024TB AB-3624TB AB-3030TB AB-3630TB AB-4830TB Panel Weight Catalog Number Type Enclosure Size (AxBxC) "D" Weight NA 1 1 1 1 2 2 3 3 4 5 6 6 7 8 AB-16126T AB-18126T AB-24126T AB-18186T AB-24186T AB-30186T AB-24246T AB-30246T AB-36246T AB-30306T AB-36306T AB-48306T AB-48366T A A A A A A A A A A A B B 16x12x6 18x12x6 24x12x6 18x18x6 24x18x6 30x18x6 24x24x6 30x24x6 36x24x6 30x30x6 36x30x6 48x30x6 48x36x6 1 1/16" 1 1/16" 1 1/16" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 2 1/4" 3 1/4" 3 1/4" 14 18 23 25 30 38 37 45 59 62 78 124 150 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Backboard Catalog Number AB-1612TB AB-1812TB AB-2412TB AB-1818TB AB-2418TB AB-3018TB AB-2424TB AB-3024TB AB-3624TB AB-3030TB AB-3630TB AB-4830TB AB-4836TB Phone: 336.468.2851 800.288.2851 Panel Weight 1 1 2 2 3 3 4 5 6 6 7 8 12 15 Type 1 & 3R Enclosures NEMA TYPE 3R S M A L L W E AT H E R P R O O F CABINETS Austin small hinge cover NEMA 3R cabinets are Underwriters Laboratories Listed and designed for outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. Construction: Finish: Options: • Fabricated in accordance • External mounting feet. with UL specifications from • Stand-offs provided for code gauge steel. mounting optional panel. • Galvanized continuous hinge with stainless steel hinge pin. Austin small hinge cover NEMA 3R cabinets are constructed standard in galvanized steel with an ANSI 61 gray polyester powder coating. Optional panels are painted white. • Special knockouts or knockout arrangements in bottom only. • Draw pull catch; AB-1. • Special materials. • Special finishes. • Custom box size or construction. • Seamless dripshield. B-2.00 .500 1.25 PANEL OPTIONAL .50 DOOR A+.75 A HINGE SIDE C B PADLOCKABLE DRAW PULL LATCH INDUSTRY STANDARDS UL 50 Type 3R NEMA Type 3R CUL Type 3R Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 1 & 3R Enclosures NEMA TYPE 3R SMALL W E AT H E R P R O O F C A B I N E T S Catalog Number AB-664WS AB-864WS AB-886WS AB-1086WS AB-10106WS AB-12106WS AB-12126WS AB-14126WS Enclosure Size (AxBxC) Weight Panel Catalog Number Panel Weight 6x6x4 8x6x4 5 6 AB-66NP AB-86NP 0.5 1 8x8x6 10x8x6 10x10x6 12x10x6 12x12x6 14x12x6 8 9 10 11 14 16 AB-88NP AB-108NP AB-1010NP AB-1210NP AB-1212NP AB-1412NP 1 1.5 2 2 3 3 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 17 Type 1 & 3R Enclosures NEMA TYPE 3R LARGE W E AT H E R P R O O F C A B I N E T S Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number Panel Weight AB-16126WL AB-16166WL AB-20166WL AB-24186WL AB-24246WL AB-36366WL 16x12x6 16x16x6 20x16x6 24x18x6 24x24x6 36x36x6 13 17 20 27 36 94 AB-1612TP AB-1616TP AB-2016TP AB-2418TP AB-2424TP AB-3636TP 4 6 7 8 15 37 AB-20208WL AB-24208WL AB-24248WL AB-30248WL AB-36248WL AB-36308WL AB-36368WL 20x20x8 24x20x8 24x24x8 30x24x8 36x24x8 36x30x8 36x36x8 27 31 40 47 61 87 102 AB-2020TP AB-2420TP AB-2424TP AB-3024TP AB-3624TP AB-3630TP AB-3636TP 9 13 15 19 24 30 37 Catalog Number Enclosure Size (AxBxC) Weight AB-242410WL AB-362410WL AB-363610WL AB-484810WL 24x24x10 36x24x10 36x36x10 48x48x10 44 67 109 234 AB-2424TP AB-3624TP AB-3636TP AB-4848TP 15 24 37 80 AB-303012WL AB-362412WL AB-363012WL AB-363612WL AB-423012WL AB-423612WL AB-483612WL AB-484812WL AB-603612WL 30x30x12 36x24x12 36x30x12 36x36x12 42x30x12 42x36x12 48x36x12 48x48x12 60x36x12 88 72 102 117 115 133 172 247 208 AB-3030TP AB-3624TP AB-3630TP AB-3636TP AB-4230TP AB-4236TP AB-4836TP AB-4848TP AB-6036TP 24 24 30 37 35 43 49 75 61 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Panel Catalog Number Panel Weight Phone: 336.468.2851 800.288.2851 19 Type 1 & 3R Enclosures NEMA TYPE 3R LARGE W E AT H E R P R O O F C A B I N E T S Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number Panel Weight AB-16126WL AB-16166WL AB-20166WL AB-24186WL AB-24246WL AB-36366WL 16x12x6 16x16x6 20x16x6 24x18x6 24x24x6 36x36x6 13 17 20 27 36 94 AB-1612TP AB-1616TP AB-2016TP AB-2418TP AB-2424TP AB-3636TP 4 6 7 8 15 37 AB-20208WL AB-24208WL AB-24248WL AB-30248WL AB-36248WL AB-36308WL AB-36368WL 20x20x8 24x20x8 24x24x8 30x24x8 36x24x8 36x30x8 36x36x8 27 31 40 47 61 87 102 AB-2020TP AB-2420TP AB-2424TP AB-3024TP AB-3624TP AB-3630TP AB-3636TP 9 13 15 19 24 30 37 Catalog Number Enclosure Size (AxBxC) Weight AB-242410WL AB-362410WL AB-363610WL AB-484810WL 24x24x10 36x24x10 36x36x10 48x48x10 44 67 109 234 AB-2424TP AB-3624TP AB-3636TP AB-4848TP 15 24 37 80 AB-303012WL AB-362412WL AB-363012WL AB-363612WL AB-423012WL AB-423612WL AB-483612WL AB-484812WL AB-603612WL 30x30x12 36x24x12 36x30x12 36x36x12 42x30x12 42x36x12 48x36x12 48x48x12 60x36x12 88 72 102 117 115 133 172 247 208 AB-3030TP AB-3624TP AB-3630TP AB-3636TP AB-4230TP AB-4236TP AB-4836TP AB-4848TP AB-6036TP 24 24 30 37 35 43 49 75 61 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Panel Catalog Number Panel Weight Phone: 336.468.2851 800.288.2851 19 NEMA 4, 12 STYLE-LINE ENCLOSURES Type 4 & 12 Enclosures Austin Style-Line enclosures are Underwriters Laboratories Listed and are designed to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. Construction: NEOPRENE GASKET (3/16 x 3/4) 60° • Fabricated in accordance with UL specifications from UL approved gauge steel. .63 DOOR OPENED 180° • Continuously welded seams ground smooth. M6x10 HEX HD SCREW ZINC PLATED • Standard collar studs for mounting optional panel. SECTION X-X • Mounting holes in back of enclosure for direct mounting or for optional external mounting feet. B REMOVABLE PIN 180° HINGE 1/4 TURN N-4 LATCH w/RECESSED SLOT A PANEL (Optional) GROUND STUD (10-32 PEM STUD) GROUND STUD (10-32 PEM STUD) X X .810 1.000 FRONT VIEW C • Neoprene gasket attached to door with oil resistant adhesive. • Door stiffener and/or body stiffener required for larger sizes. • Quarter turn latches for enclosures up through 36". .437 DIA. TYP. MTG. HOLE 3/8"-16 COLLAR STUD (4 PLACES) • Doors can be easily removed by pulling captive hinge pins. • Grounding stud in body. 4.000 4.000 • Enclosure opening has a rolled lip to exclude liquids and contaminants. • Three-point latch on enclosures over 36". .690 1.310 .25 DIA. HINGE MTG. HOLE (2 PLACES) PANEL A-3.00 B-3.00 4.000 1.000 2.380 1.000 2.380 FRONT VIEW w/DOOR REMOVED INDUSTRY STANDARDS UL 50 UL 508 CUL NEMA Types Types Types Types 4 4 4 4 & & & & 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Finish: Austin Style-Line enclosures are provided standard with an ANSI 61 gray polyester powder coating inside and out. Stainless steel Style-Line enclosures are provided standard in Type 304 stainless steel. Optional panels are painted white. Type 4 & 12 Enclosures NEMA 4, NEMA 12 STYLE-LINE ENCLOSURES Options: • Special finishes. • Handles or inserts Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 21 NEMA 4, 12 STYLE-LINE ENCLOSURES Type 4 & 12 Enclosures B REMOVABLE PIN 180° HINGE DOOR STIFFENER MOUNTED HORIZONTAL (INSIDE DOOR) 3 POINT LATCH N-4 w/PADLOCKING SLOT A X X PANEL (Optional) GROUND STUD (10-32 PEM STUD INSIDE DOOR) GROUND STUD (10-32 PEM STUD INSIDE ENCLOSURE) .810 1.000 4.000 C FRONT VIEW LEFT SIDE VIEW .437 DIA. TYP. MTG. HOLE 3/8"-16 COLLAR STUD (8 PLACES) .690 1.310 PANEL (Optional) BODY STIFFENER MOUNTED HORIZONTAL (INSIDE ENCLOSURE) A-3.00 .25 DIA. HINGE MTG HOLE NEOPRENE GASKET (3/16 x 3/4) 60° .63 B-3.00 2.380 4.000 .750 .750 M6x10 HEX HD SCREW ZINC PLATED 2.380 FRONT VIEW w/DOOR REMOVED INDUSTRY STANDARDS DOOR OPENED 180° UL 50 UL 508 CUL NEMA Types Types Types Types SECTION X-X 4 4 4 4 & & & & 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 4 & 12 Enclosures NEMA 4, NEMA 12 STYLE-LINE ENCLOSURES Catalog Number Catalog Number Stainless Steel Enclosure Size (AxBxC) Weight Panel Catalog Number Door Stiffener Body Stiffener Hinge Qty. Latch Qty. AB-12126SL AB-16126SL AB-16166SL AB-20166SL AB-20206SL AB-12126SLX AB-16126SLX AB-16166SLX AB-20166SLX AB-20206SLX 12x12x6 16x12x6 16x16x6 20x16x6 20x20x6 13 16 19 23 28 AB-1212TP AB-1612TP AB-1616TP AB-2016TP AB-2020TP - - 2 2 2 2 2 1 1 1 1 1 AB-16208SL AB-20168SL AB-20208SL AB-20248SL AB-24168SL AB-24208SL AB-24248SL AB-24308SL AB-30208SL AB-30248SL AB-30308SL AB-36248SL AB-36308SL AB-16208SLX AB-20168SLX AB-20208SLX AB-20248SLX AB-24168SLX AB-24208SLX AB-24248SLX AB-24308SLX AB-30208SLX AB-30248SLX AB-30308SLX AB-36248SLX AB-36308SLX 16x20x8 20x16x8 20x20x8 20x24x8 24x16x8 24x20x8 24x24x8 24x30x8 30x20x8 30x24x8 30x30x8 36x24x8 36x30x8 26 26 31 36 31 36 42 50 43 50 60 58 70 AB-1620TP AB-2016TP AB-2020TP AB-2420TP AB-2416TP AB-2420TP AB-2424TP AB-3024TP AB-3020TP AB-3024TP AB-3030TP AB-3624TP AB-3630TP - 1 1 2 2 2 2 2 2 2 2 2 2 2 3 3 1 1 1 2 2 2 2 2 2 2 2 2 2 AB-202012SL AB-242412SL AB-302412SL AB-363012SL AB-363612SL AB-402412SL AB-423612SL AB-482412SL AB-483612SL AB-602412SL AB-603612SL AB-202012SLX AB-242412SLX AB-302412SLX AB-363012SLX AB-363612SLX AB-402412SLX AB-423612SLX AB-482412SLX AB-483612SLX AB-602412SLX AB-603612SLX 20x20x12 24x24x12 30x24x12 36x30x12 36x36x12 40x24x12 42x36x12 48x24x12 48x36x12 60x24x12 60x36x12 38 50 59 81 94 75 106 88 118 106 144 AB-2020TP AB-2424TP AB-3024TP AB-3630TP AB-3636TP AB-4024TP AB-4236TP AB-4824TP AB-4836TP AB-6024TP AB-6036TP 1 1 1 1 1 1 1 1 1 1 1 2 2 2 3 3 3 3 3 3 3 3 1 2 2 2 2 3 pt. 3 pt. 3 pt. 3 pt. 3 pt. 3 pt. AB-242416SL AB-363016SL AB-483616SL AB-242416SLX AB-363016SLX AB-483616SLX 24x24x16 36x30x16 48x36x16 58 93 133 AB-2424TP AB-3630TP AB-4836TP 1 1 1 2 3 3 2 2 3 pt. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 23 NEMA 4 SINGLE DOOR ENCLOSURES Type 4 & 12 Enclosures Austin NEMA 4 single door enclosures are Underwriters Laboratories Listed and are designed for use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Door removed by pulling stainless steel continuous hinge pin. • All seams continuously welded and ground smooth. • Neoprene gasket attached to door with oil resistant adhesive. • Rolled lip around three sides of door and all sides of door opening for watertight seal. • Clamps on three sides of door for watertight seal. • Stainless steel external hardware. * THIS DIMENSION IS 1.50" WHEN "B" IS LESS THAN 16.00" B .63 3.00* C 3.00* Y • Hasp and staple provided for padlocking. X 1.06 • External mounting feet. Y • Standard plastic self-adhesive print pocket. • Standard collar studs for mounting optional panel. PADDLOCK TYPE HASP A Finish: Austin NEMA 4 single door enclosures are provided standard with an ANSI 61 gray polyester powder coating inside and out. Optional panels are painted white. 4.00 OR (TYP) 6.00 MAXIMUM CLAMP SPACING IS 15.00" .63 X DEPENDING ON ENCLOSURE SIZE .43 DIA. Options: OMIT TWO MIDDLE STUDS IF "B" IS LESS THAN 31.00" PANEL (Optional) GASKET CONTINUOUS HINGE B-3.00 • Special finishes. 1.38 3/8-16 COLLAR STUD A-3.00 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31.00" • Special materials. 1.00 • Custom box size or construction. SECTION Y-Y .88 .88 SECTION X-X INDUSTRY STANDARDS UL 50 Types UL 508 Types NEMA Types CUL Types 4 4 4 4 & & & & 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-16126NF AB-16166NF AB-20166NF AB-16206NF AB-20206NF AB-24126NF AB-24166NF AB-24206NF AB-24246NF AB-30206NF AB-30246NF AB-36246NF 16x12x6 16x16x6 20x16x6 16x20x6 20x20x6 24x12x6 24x16x6 24x20x6 24x24x6 30x20x6 30x24x6 36x24x6 23 28 32 32 38 31 37 43 49 53 60 69 AB-1612TP AB-1616TP AB-2016TP AB-1620TP AB-2020TP AB-2412TP AB-2416TP AB-2420TP AB-2424TP AB-3020TP AB-3024TP AB-3624TP AB-16128NF AB-20168NF AB-20208NF AB-24208NF AB-24248NF AB-30208NF AB-30248NF 16x12x8 20x16x8 20x20x8 24x20x8 24x24x8 30x20x8 30x24x8 25 35 42 47 54 57 65 AB-1612TP AB-2016TP AB-2020TP AB-2420TP AB-2424TP AB-3020TP AB-3024TP Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-30308NF AB-36248NF AB-36308NF AB-42308NF AB-42368NF AB-48368NF AB-60368NF 30x30x8 36x24x8 36x30x8 42x30x8 42x36x8 48x36x8 60x36x8 78 74 92 106 125 139 167 AB-3030TP AB-3624TP AB-3630TP AB-4230TP AB-4236TP AB-4836TP AB-6036TP AB-201610NF AB-242010NF AB-302410NF AB-363010NF AB-483010NF AB-483610NF AB-603610NF 20x16x10 24x20x10 30x24x10 36x30x10 48x30x10 48x36x10 60x36x10 39 52 70 98 125 147 176 AB-2016TP AB-2420TP AB-3024TP AB-3630TP AB-4830TP AB-4836TP AB-6036TP AB-302412NF AB-363012NF AB-483612NF 30x24x12 36x30x12 48x36x12 75 104 154 AB-3024TP AB-3630TP AB-4836TP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 4 & 12 Enclosures NEMA 4 SINGLE DOOR ENCLOSURES 25 NEMA 4 DOUBLE DOOR ENCLOSURES Type 4 & 12 Enclosures Austin NEMA 4 double door enclosures are Underwriters Laboratories Listed and designed for use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Rolled lip around three sides of door and along top of enclosure for watertight seal. • All seams continuously welded and ground smooth. • Removable centerpost with gasket. • Hasp and staple provided for padlocking. • Neoprene gasket attached to doors with oil resistant adhesive. • Standard plastic self-adhesive print pocket. • Clamps on three sides of door for watertight seal. • 12" floor stands welded on. • Heavy duty lifting eyes. • Stainless steel external hardware. • Standard collar studs for mounting optional panel. Finish: LIFTING EYE Austin NEMA 4 double door enclosures are provided standard with an ANSI 61 gray polyester powder coating inside and out. Optional panels are painted white. C B T 1.25" Options: • Special materials. HASP FOR PADLOCK A • Special finishes. • Custom box size or construction. 15"MAX S S 12.000 B - 4" REMOVABLE CENTERPOST T CONTINUOUS HINGE PANEL (Optional) GASKET 1.38 1.25 A - 6" 3/8-16 COLLAR STUD .875 .875 1.00 SECTION S-S SECTION T-T INDUSTRY STANDARDS UL 50 Types UL 508 Types NEMA Types CUL Types 4 4 4 4 & & & & 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Enclosure Number Size (AxBxC) Weight Type 4 & 12 Enclosures NEMA 4 DOUBLE DOOR ENCLOSURES Panel Catalog Number AB-624810NFD 62x48x10 357 AB-6048DP AB-626010NFD 62x60x10 507 AB-6060DP AB-746012NFD 74x60x12 560 AB-7260DP AB-747212NFD 74x72x12 626 AB-7272DP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 27 NEMA 4X S TA I N L E S S S T E E L E N C L O S U R E S Type 4 & 12 Enclosures Austin NEMA 4X stainless steel single door enclosures are Underwriters Laboratories Listed and are designed for use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: • Fabricated in accordance with UL specifications from 14 or 12 gauge Type 304 stainless steel standard, Type 316 stainless steel optional. • Neoprene gasket attached to door with oil resistant adhesive. • Clamps on three sides of door for watertight seal. • All seams continuously welded and ground smooth. • Stainless steel external hardware. • Rolled lip around three sides of door and all sides of door opening for watertight seal. • Hasp and staple provided for padlocking. • External mounting feet. • Standard plastic self-adhesive print pocket. * THIS DIMENSION IS 1.50" WHEN "B" IS LESS THAN 16.00" B .63 3.00* • Standard collar studs for mounting optional panel. C 3.00* X 1.06 Y Y Finish: PADDLOCK TYPE HASP Austin NEMA 4X stainless steel single door enclosures are provided standard in type 304 polished stainless steel. Optional panels are painted white, stainless steel panels are unpainted. A 4.00 OR (TYP) 6.00 MAXIMUM CLAMP SPACING IS 15.00" .63 Options: X DEPENDING ON ENCLOSURE SIZE • Custom Custom box box size size or or construction. construction. .43 DIA. • Type 316 stainless steel. OMIT TWO MIDDLE STUDS IF "B" IS LESS THAN 31.00" PANEL (Optional) B-3.00 GASKET CONTINUOUS HINGE 1.38 3/8-16 COLLAR STUD A-3.00 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31.00" .88 1.00 SECTION Y-Y .88 SECTION X-X INDUSTRY STANDARDS UL 50 Types UL 508 Types NEMA Types CUL Types 4X, 4X, 4X, 4X, 4 4 4 4 & & & & 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 4 & 12 Enclosures S TA I N L E S S S T E E L N E M A 4 X E N C L O S U R E S Catalog Number Enclosure Size (AxBxC) Enclosure Weight Panel Catalog Number Panel Weight AB-16126NFX AB-16166NFX AB-20166NFX AB-20206NFX AB-24246NFX 16x12x6 16x16x6 20x16x6 20x20x6 24x24x6 16 20 23 28 38 AB-1612TP AB-1616TP AB-2016TP AB-2020TP AB-2424TP 4 6 7 9 15 AB-24248NFX AB-24308NFX AB-30208NFX AB-30248NFX AB-36248NFX AB-36308NFX AB-42368NFX 24x24x8 24x30x8 30x20x8 30x24x8 36x24x8 36x30x8 42x36x8 42 50 43 50 58 98 130 AB-2424TP AB-3024TP AB-3020TP AB-3024TP AB-3624TP AB-3630TP AB-4236TP 15 19 16 19 24 30 43 Catalog Number Enclosure Size (AxBxC) Enclosure Weight Panel Catalog Number Panel Weight AB-48368NFX 48x36x8 146 AB-4836TP 49 AB-201610NFX AB-242010NFX AB-362410NFX AB-363010NFX AB-423010NFX 20x16x10 24x20x10 36x24x10 36x30x10 42x30x10 30 40 64 106 120 AB-2016TP AB-2420TP AB-3624TP AB-3630TP AB-4230TP 7 13 24 30 35 AB-242412NFX AB-302412NFX AB-363012NFX AB-483612NFX AB-603612NFX 24x24x12 30x24x12 36x30x12 48x36x12 60x36x12 50 59 114 166 201 AB-2424TP AB-3024TP AB-3630TP AB-4836TP AB-6036TP 15 19 30 49 61 *Optional stainless steel panels are available Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 29 NEMA 4X ALUMINUM ENCLOSURES Type 4 & 12 Enclosures Austin NEMA 4X aluminum enclosures are Underwriters Laboratories Listed and are designed for use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: • Fabricated in accordance with UL specifications form Type 5052-H32 aluminum. • Neoprene gasket attached to door with oil resistant adhesive. • Hasp and staple provided for padlocking. • Clamps on three sides of door for watertight seal. • All seams continuously welded and ground smooth. • Standard plastic selfadhesive print pocket. • Aluminum continuous hinge. • Rolled lip around three sides of door and all sides of door opening for watertight seal. • Stainless steel external hardware. B 3.00* • Standard collar studs for mounting optional panel. Finish: * THIS DIMENSION IS 1.50" WHEN "B" IS LESS THAN 16.00" .63 • External mounting feet C Y Austin NEMA 4X aluminum enclosures are provided standard in Type 5052-H32 aluminum. Optional panels are painted white. Aluminum panels are unpainted. X 3.00* 1.06 Y PADDLOCK TYPE HASP A Options: 4.00 OR (TYP) 6.00 MAXIMUM CLAMP SPACING IS 15.00" .63 DEPENDING ON ENCLOSURE SIZE Custom box box size size or or construction. construction. •• Custom X .43 DIA. OMIT TWO MIDDLE STUDS IF "B" IS LESS THAN 31.00" PANEL (Optional) B-3.00 GASKET CONTINUOUS HINGE 1.38 3/8-16 COLLAR STUD A-3.00 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31.00" SECTION Y-Y 1.00 .88 .88 SECTION X-X INDUSTRY STANDARDS UL 50 Types UL 508 Types NEMA Types CUL Types 4X, 4X, 4X, 4X, 4 4 4 4 & & & & 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Steel Panel Catalog Number AB-16126NFA AB-20166NFA AB-20206NFA AB-24206NFA 16x12x6 20x16x6 20x20x6 24x20x6 6 8 10 12 AB-1612TP AB-2016TP AB-2020TP AB-2420TP AB-24248NFA AB-30248NFA AB-36248NFA AB-36308NFA AB-48368NFA 24x24x8 30x24x8 36x24x8 36x30x8 48x36x8 17 20 24 32 47 AB-2424TP AB-3024TP AB-3624TP AB-3630TP AB-4836TP AB-201610NFA AB-242010NFA 20x16x10 24x20x10 11 14 AB-2016TP AB-2420TP AB-302412NFA AB-363012NFA AB-603612NFA 30x24x12 36x30x12 60x36x12 24 37 65 AB-3024TP AB-3630TP AB-6036TP Type 4 & 12 Enclosures ALUMINUM NEMA 4X ENCLOSURES *Optional aluminum panels are available Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 31 NEMA 12 SINGLE DOOR ENCLOSURES Type 4 & 12 Enclosures .43 DIA. PANEL (Optional) B-3.00 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31.00" A-3.00 OMIT TWO MIDDLE STUDS IF "B" IS LESS THAN 31.00" .88 .88 SECTION X-X * THIS DIMENSION IS 1.50" WHEN "B" IS LESS THAN 16.00" B .63 C 3.00* 3.00* 1.06 Y X Y PADLOCK TYPE HASP A ADDITIONAL CLAMP USED IN CENTER WHEN "A" EXCEEDS 47" AND HASP MOVED UP. 4.00 (TYP) X .63 GASKET CONTINUOUS HINGE 1.38 3/8-16 COLLAR STUD 1.00 SECTION Y-Y INDUSTRY STANDARDS UL 50 Type UL 508 Type NEMA Type CUL Type 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Austin NEMA 12 single door enclosures are Underwriters Laboratories Listed and are designed for indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: Finish: • Fabricated in accordance with UL specifications from code gauge steel. Austin Type 12 Single door enclosures are provided standard with an ANSI 61 gray polyester powder coating inside and out. Optional panels are finished white. • Continuously welded seams ground smooth. Type 4 & 12 Enclosures NEMA 12 SINGLE DOOR ENCLOSURES • Door removed by pulling continuous hinge pin. • Neoprene gasket attached to door with oil resistant adhesive. • Hasp and staple provided for padlocking. • External feet for mounting enclosure. Options: • Special materials. • Special finishes. • Custom Custom box box size size or or construction. construction. • Standard plastic self-adhesive print pocket. • Standard collar studs for mounting optional panel. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 33 NEMA 12 SINGLE DOOR ENCLOSURES Type 4 & 12 Enclosures * THIS DIMENSION IS 1.50" WHEN "B" IS LESS THAN 16.00" B .63 C 3.00* 3.00* Y 1.06 X .43 DIA. Y PANEL (Optional) PADLOCK TYPE HASP A B-3.00 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31.00" A-3.00 OMIT TWO MIDDLE STUDS IF "B" IS LESS THAN 31.00" .88 .88 4.00 (TYP) X .63 SECTION X-X GASKET CONTINUOUS HINGE 1.38 3/8-16 COLLAR STUD 1.00 SECTION Y-Y INDUSTRY STANDARDS UL 50 Type UL 508 Type NEMA Type CUL Type 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Enclosure Weight Panel Catalog Number Panel Weight AB-12246N AB-16126N AB-16166N AB-20126N AB-20166N AB-16206N AB-20206N AB-24126N AB-24166N AB-20246N AB-24206N AB-24246N AB-30166N AB-30206N AB-30246N AB-36246N AB-36306N 12x24x6 16x12x6 16x16x6 20x12x6 20x16x6 16x20x6 20x20x6 24x12x6 24x16x6 20x24x6 24x20x6 24x24x6 30x16x6 30x20x6 30x24x6 36x24x6 36x30x6 29 22 27 26 31 31 36 30 37 42 41 48 41 51 58 69 84 AB-1224TP AB-1612TP AB-1616TP AB-2012TP AB-2016TP AB-1620TP AB-2020TP AB-2412TP AB-2416TP AB-2024TP AB-2420TP AB-2424TP AB-3016TP AB-3020TP AB-3024TP AB-3624TP AB-3630TP 8 4 6 5 7 7 9 7 9 13 13 15 12 16 19 24 30 AB-16128N AB-16168N AB-20128N AB-20168N AB-16208N AB-20208N AB-24128N AB-12248N AB-24168N AB-24208N AB-20248N AB-24248N AB-30208N AB-30248N AB-24308N AB-30308N AB-36248N AB-36308N AB-30368N AB-36368N AB-42248N AB-42308N AB-42368N AB-48248N AB-48308N AB-48368N AB-60368N 16x12x8 16x16x8 20x12x8 20x16x8 16x20x8 20x20x8 24x12x8 12x24x8 24x16x8 24x20x8 20x24x8 24x24x8 30x20x8 30x24x8 24x30x8 30x30x8 36x24x8 36x30x8 30x36x8 36x36x8 42x24x8 42x30x8 42x36x8 48x24x8 48x30x8 48x36x8 60x36x8 24 31 28 34 34 40 33 33 40 46 46 52 55 63 62 75 72 90 89 102 82 101 119 92 113 133 160 AB-1612TP AB-1616TP AB-2012TP AB-2016TP AB-1620TP AB-2020TP AB-2412TP AB-1224TP AB-2416TP AB-2420TP AB-2024TP AB-2424TP AB-3020TP AB-3024TP AB-2430TP AB-3030TP AB-3624TP AB-3630TP AB-3036TP AB-3636TP AB-4224TP AB-4230TP AB-4236TP AB-4824TP AB-4830TP AB-4836TP AB-6036TP 4 6 5 7 7 9 7 7 15 13 13 15 16 19 19 30 24 30 30 37 28 35 43 32 40 49 61 AB-161210N AB-201610N 16x12x10 20x16x10 27 38 AB-1612TP AB-2016TP 4 7 Catalog Number Enclosure Size (AxBxC) Enclosure Weight Panel Catalog Number Panel Weight AB-202010N AB-241210N AB-242010N AB-242410N AB-302010N AB-302410N AB-362410N AB-363010N AB-423010N AB-423610N AB-483010N AB-483610N AB-603610N 20x20x10 24x12x10 24x20x10 24x24x10 30x20x10 30x24x10 36x24x10 36x30x10 42x30x10 42x36x10 48x30x10 48x36x10 60x36x10 44 36 50 56 60 68 78 96 108 126 120 141 169 AB-2020TP AB-2412TP AB-2420TP AB-2424TP AB-3020TP AB-3024TP AB-3624TP AB-3630TP AB-4230TP AB-4236TP AB-4830TP AB-4836TP AB-6036TP 9 7 13 15 16 19 24 30 35 43 40 49 61 AB-201612N AB-242012N AB-242412N AB-302412N AB-303012N AB-362412N AB-363012N AB-363612N AB-423012N AB-423612N AB-483612N AB-603612N AB-723012N 20x16x12 24x20x12 24x24x12 30x24x12 30x30x12 36x24x12 36x30x12 36x36x12 42x30x12 42x36x12 48x36x12 60x36x12 72x30x12 41 54 61 73 89 83 102 117 115 132 148 178 177 AB-2016TP AB-2420TP AB-2424TP AB-3024TP AB-3030TP AB-3624TP AB-3630TP AB-3636TP AB-4230TP AB-4236TP AB-4836TP AB-6036TP AB-7230TP 7 13 15 19 24 24 30 37 35 43 49 61 62 AB-242016N AB-242416N AB-302416N AB-363016N AB-423616N AB-483616N AB-603616N AB-723016N 24x20x16 24x24x16 30x24x16 36x30x16 42x36x16 48x36x16 60x36x16 72x30x16 62 70 82 114 147 164 195 196 AB-2420TP AB-2424TP AB-3024TP AB-3630TP AB-4236TP AB-4836TP AB-6036TP AB-7230TP 13 15 19 30 43 49 61 62 AB-722418N 72x24x18 157 AB-7224TP 49 AB-302420N AB-363020N AB-483620N AB-603620N AB-723020N 30x24x20 36x30x20 48x36x20 60x36x20 72x30x20 92 125 178 211 215 AB-3024TP AB-3630TP AB-4836TP AB-6036TP AB-7230TP 19 30 49 61 62 AB-722424N AB-723024N 72x24x24 72x30x24 184 234 AB-7224TP AB-7230TP 49 62 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 4 & 12 Enclosures NEMA 12 SINGLE DOOR ENCLOSURES 35 NEMA 12 DOUBLE DOOR ENCLOSURES Type 4 & 12 Enclosures Austin NEMA 12 double door enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Heavy duty lifting eyes. • Heavy gauge continuous hinge. • Continuously welded seams ground smooth. • Neoprene gasket attached to doors with oil resistant adhesive. • Overlapping doors eliminate need for centerpost. • Standard plastic self-adhesive print pocket. • An AB-6 three point lever handle with roller arms holds doors securely. • Standard collar studs provided for mounting optional panel. • 12" legs are welded to enclosure. Finish: C B 1.25 X LIFTING EYES PANEL Austin double door NEMA 12 enclosures are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. Y A Y Options: • Special materials. 12.000 12" LEGS • Special finishes. X • Custom box size or construction. B - 4" 1.25 PANEL (Optional) A - 4" 1.25 CONTINUOUS HINGE AB-6 HANDLE AB-7 w/LOCK (Optional) CONTINUOUS 1.38 HINGE GASKET 3/8-16 COLLAR STUD 1.38 .88 GASKET SECTIO 3/8-16 COLLAR STUD .88 SECTION Y-Y SECTION X-X INDUSTRY STANDARDS UL 50 Type UL 508 Type NEMA Type CUL Type 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-54428ND AB-60488ND 54x42x8 60x48x8 210 319 AB-5442DP AB-6048DP AB-604810ND AB-606010ND AB-726010ND AB-727210ND 60x48x10 60x60x10 72x60x10 72x72x10 330 390 450 525 AB-6048DP AB-6060DP AB-7260DP AB-7272DP AB-604812ND AB-606012ND AB-726012ND AB-727212ND 60x48x12 60x60x12 72x60x12 72x72x12 360 400 475 560 AB-6048DP AB-6060DP AB-7260DP AB-7272DP Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-604816ND AB-606016ND AB-726016ND AB-727216ND 60x48x16 60x60x16 72x60x16 72x72x16 420 520 582 630 AB-6048DP AB-6060DP AB-7260DP AB-7272DP AB-604820ND AB-726020ND AB-727220ND 60x48x20 72x60x20 72x72x20 486 577 650 AB-6048DP AB-7260DP AB-7272DP AB-604824ND AB-606024ND AB-726024ND AB-727224ND 60x48x24 60x60x24 72x60x24 72x72x24 500 566 614 690 AB-6048DP AB-6060DP AB-7260DP AB-7272DP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 4 & 12 Enclosures NEMA 12 DOUBLE DOOR ENCLOSURES 37 NEMA 12 FLUSH MOUNT ENCLOSURES Type 4 & 12 Enclosures Austin flush NEMA 12 enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and noncorrosive liquids. Construction: Finish: • Fabricated in accordance with UL specifications from code gauge steel. • Continuous hinge on one side and screws on opposite side to hold door in place. • Continuously welded seams ground smooth. • 10 gauge trim around enclosure. • Neoprene gasket attached to door with oil resistant adhesive. • Standard plastic self-adhesive print pocket. • Standard collar studs for mounting optional panel. Austin flush NEMA 12 enclosures are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. Options: • Special materials. • Special finishes. • Custom box size or construction. B+2.50 B Y Y C+1.06 A+2.50 A C PANEL (Optional) CONTINUOUS HINGE 1.25 GASKET 2.00 1.38 C+1.06 C 1.00 SECTION Y-Y INDUSTRY STANDARDS UL 50 Type UL 508 Type NEMA Type CUL Type 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-16126FN AB-20166FN AB-20206FN AB-24206FN 16x12x6 20x16x6 20x20x6 24x20x6 27 38 44 50 AB-1612TP AB-2016TP AB-2020TP AB-2420TP AB-24248FN AB-30248FN AB-36248FN AB-36308FN 24x24x8 30x24x8 36x24x8 36x30x8 61 73 83 104 AB-2424TP AB-3024TP AB-3624TP AB-3630TP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4 & 12 Enclosures NEMA 12 FLUSH ENCLOSURES Phone: 336.468.2851 800.288.2851 39 NEMA 12 ALUMINUM ENCLOSURES Type 4 & 12 Enclosures Austin NEMA 12 aluminum enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and noncorrosive liquids. Construction: Finish: • Fabricated in accordance with • External feet for mounting UL specifications from enclosure. 5052-H32 aluminum. • Standard plastic self-adhesive • Continuously welded seams print pocket. ground smooth. • Standard collar studs for • Aluminum continuous hinge. mounting optional panel. Austin NEMA 12 aluminum enclosures are provided standard in 5052-H32 aluminum. Optional steel panels are painted white. Aluminum panels are unpainted. Options: • Neoprene gasket attached to door with oil resistant adhesive. • Custom box size or construction. • Hasp and staple provided for padlocking. * THIS DIMENSION IS 1.50" WHEN "B" IS LESS THAN 16.00" B .63 C 3.00* 3.00* 1.06 Y X .43 DIA. Y PANEL (Optional) B-3.00 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31.00" PADLOCK TYPE HASP A A-3.00 OMIT TWO MIDDLE STUDS IF "B" IS LESS THAN 31.00" .88 .88 4.00 (TYP) X .63 SECTION X-X GASKET CONTINUOUS HINGE 1.38 3/8-16 COLLAR STUD 1.00 INDUSTRY STANDARDS SECTION Y-Y UL 50 Type UL 508 Type NEMA Type CUL Type 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Steel Panel Catalog Number AB-16126NA AB-20166NA AB-20206NA AB-24206NA 16x12x6 20x16x6 20x20x6 24x20x6 6 9 10 12 AB-1612TP AB-2016TP AB-2020TP AB-2420TP AB-24248NA AB-30248NA AB-36248NA AB-36308NA AB-48368NA 24x24x8 30x24x8 36x24x8 36x30x8 48x36x8 17 20 24 31 47 AB-2424TP AB-3024TP AB-3624TP AB-3630TP AB-4836TP AB-201610NA AB-242010NA 20x16x10 24x20x10 11 14 AB-2016TP AB-2420TP AB-302412NA AB-363012NA AB-603612NA 30x24x12 36x30x12 60x36x12 24 37 65 AB-3024TP AB-3630TP AB-6036TP Type 4 & 12 Enclosures NEMA 12 ALUMINUM ENCLOSURES *Optional aluminum panels are available Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 41 NEMA 12 S I N G L E D O O R F R E E S TA N D I N G ENCLOSURES Type 4 & 12 Enclosures Austin freestanding single door NEMA 12 enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: Finish: • Heavy gauge continuous hinge. • Fabricated in accordance with UL specifications from • Heavy duty lifting eyes. code gauge steel. Austin freestanding single door NEMA 12 enclosures are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. • Continuously welded seams ground smooth. • Standard plastic self-adhesive print pocket. • Neoprene gasket attached to door with oil resistant adhesive. • Mounting channels welded horizontally to enclosure interior sides at top, bottom, and center for optional panel. Options: • Special materials. • Special finishes. • An AB-6 three point lever handle with roller arms holds door securely. • Custom box size or construction. B 1.25 C X LIFTING EYES 3" B-4.00 PANEL (Optional) A Y A-12.00 Y 7" SECTION X-X X 1.25 CONTINUOUS HINGE GASKET AB-6 HANDLE AB-7 w/LOCK (Optional) 1.38 SECTION Y-Y INDUSTRY STANDARDS UL 50 Type UL 508 Type NEMA Type CUL Type 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number Weight AB-722418FSN AB-723018FSN AB-723618FSN 72x24x18 72x30x18 72x36x18 246 285 325 AB-7224FTP AB-7230FTP AB-7236FTP 65 74 98 AB-903620FSN 90x36x20 406 AB-9036FTP 108 AB-722424FSN AB-723024FSN AB-723624FSN AB-903624FSN 72x24x24 72x30x24 72x36x24 90x36x24 300 335 370 440 AB-7224FTP AB-7230FTP AB-7236FTP AB-9036FTP 65 74 98 108 AB-722430FSN AB-723630FSN 72x24x30 72x36x30 355 420 AB-7224FTP AB-7236FTP 65 74 AB-722436FSN 72x24x36 400 AB-7224FTP 65 AB-723636FSN 72x36x36 465 AB-7236FTP 74 AB-903636FSN 90x36x36 525 AB-9036FTP 108 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4 & 12 Enclosures NEMA 12 SINGLE DOOR F R E E S TA N D I N G E N C L O S U R E S Phone: 336.468.2851 800.288.2851 43 NEMA 12 D O U B L E D O O R F R E E S TA N D I N G ENCLOSURES Type 4 & 12 Enclosures Austin freestanding double door NEMA 12 enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: Finish: • Fabricated in accordance • An AB-6 three point lever with UL specifications from handle with roller arms holds code gauge steel. doors securely. Austin freestanding double door NEMA 12 enclosures are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. • Continuously welded seams ground smooth. • Heavy gauge continuous hinge. • Heavy duty lifting eyes. • Overlapping doors eliminate need for centerpost. • Neoprene gasket attached to door with oil resistant adhesive. • Standard plastic self-adhesive print pocket. • Mounting channels welded horizontally to enclosure interior sides at top, bottom, and center for optional panel. B 1.25 Options: • Special materials. • Special finishes. • Custom box size or construction. C X LIFTING EYES 3" B-4.00 A PANEL (Optional) Y Y A-12.00 7" SECTION X-X X CONTINUOUS HINGE AB-6 HANDLE AB-7 w/LOCK (Optional) 1.25 1.38 GASKET SECTION Y-Y INDUSTRY STANDARDS UL 50 Type UL 508 Type NEMA Type CUL Type 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-724818FSND AB-726018FSND AB-727218FSND 72x48x18 72x60x18 72x72x18 500 568 645 AB-7248FTP AB-7260FTP AB-7272FTP 131 159 187 AB-907220FSND 90x72x20 781 AB-9072FTP 238 AB-724824FSND AB-726024FSND AB-727224FSND AB-907224FSND 72x48x24 72x60x24 72x72x24 90x72x24 560 645 695 825 AB-7248FTP AB-7260FTP AB-7272FTP AB-9072FTP 131 159 187 238 AB-726036FSND 72x60x36 750 AB-7260FTP 159 AB-907236FSND 90x72x36 1000 AB-9072FTP 238 Type 4 & 12 Enclosures NEMA 12 DOUBLE DOOR F R E E S TA N D I N G E N C L O S U R E S Weight Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 45 NEMA 12 DOUBLE DOOR WALL MOUNT ENCLOSURES Type 4 & 12 Enclosures Austin double door NEMA 12 wall mount enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, instruments, and components. They provide a degree of protection against circulating dust, falling dirt, and noncorrosive liquids. Construction: Finish: • Overlapping doors eliminate • Fabricated in accordance need for centerpost. with UL specifications from code gauge steel. • Heavy gauge continuous hinge. • Continuously welded • Standard plastic self-adhesive seams ground smooth. print pocket. • An AB-6 three point lever • External mounting feet. handle with roller arms Austin double door NEMA 12 wall mount enclosures are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. holds doors securely. Options: • Special materials. • Standard collar studs for mounting optional panel. • Neoprene gasket attached to door with oil resistant adhesive. • Special finishes. • Custom box size or construction. CENTER MOUNTING FEET NOT ON ENCLOSURES WITH "B" LESS THAN 48" 1.25 B C .43 DIA. X A Y Y X PANEL (Optional) AB-6 HANDLE AB-7 w/LOCK (Optional) CONTINUOUS HINGE GASKET B-3.00 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31" 1.38 1.25 3/8-16 COLLAR STUD 1.00 A-3.00 .88 SECTION Y-Y .88 SECTION X-X INDUSTRY STANDARDS UL 50 Type UL 508 Type NEMA Type CUL Type 12 12 12 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-24428WDN AB-24488WDN 24x42x8 24x48x8 67 75 AB-4224TP AB-4824TP AB-304210WDN AB-304810WDN AB-306010WDN 30x42x10 30x48x10 30x60x10 103 116 141 AB-4230TP AB-4830TP AB-6030TP AB-364212WDN AB-364812WDN AB-366012WDN AB-426012WDN 36x42x12 36x48x12 36x60x12 42x60x12 128 166 201 228 AB-4236TP AB-4836TP AB-6036TP AB-6042TP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4 & 12 Enclosures NEMA 12 DOUBLE DOOR WALL MOUNT ENCLOSURES Phone: 336.468.2851 800.288.2851 47 TYPE 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Construction: • 14 gauge steel. Flange-Mounted Disconnect Enclosures • Seams are continuously welded and ground smooth. • External mounting feet. • Door and body stiffeners in larger enclosures for rigidity. • Formed lip around all sides of enclosure opening excludes liquids and contaminants. • Door removable by pulling continuous hinge pin. • Print pocket included. • Oil-resistant gasket. • 3/8-16 threaded collar studs provided for mounting optional panel. • Holes in body and door for mounting operating handle, operating mechanism, and door closing mechanism. • Cover interlock bracket welded to door. • Furnished with door latch bar for door hardware. (disconnect switch, operating handle, operating mechanism, and door hardware are not furnished with the enclosure. They must be ordered separately from the disconnect manufacturer.) Finish: • Enclosures under 40" height require 2-point door hardware. ANSI 61 gray polyester powder paint outside and inside. Optional panels are painted white polyester powder. • Enclosures 40" high and taller require 3-point door hardware. INDUSTRY STANDARDS UL 508 Type 12 CUL Type 12 NEMA Type 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Flange-Mounted Disconnect Enclosures SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS B .62 3.00 .44 DIA. C 3.00 OMIT TWO MIDDLE STUDS IF "B" IS LESS THAN 32" X STIFFENER S S PANEL (ORDERED SEPARATELY) A A-3.00 B-4 3/8 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31" X .44 .62 SECTION X-X DOOR STIFFENER CONTINUOUS HINGE DOOR STIFFENER 1.38 2.75 3/8-16 COLLAR STUD MOUNTING FEET MOUNTING FEET SPACE OCCUPIED BY DISCONNECT NEOPRENE GASKET BODY STIFFENER SECTION S-S NOTE: D = 4.75 WHEN C = 8.00 D = 7.09 WHEN C = 12.00 D = 11.62 WHEN C = 12.00 D = 11.62 WHEN C = 16.00 W = WIRING SPACE PANEL (ORDERED SEPARATELY) 1.50 W D CL TOP HOLE IN R.H. FLANGE E THIS SPACE IS OCCUPIED BY DISCONNECT SWITCH AND FUSE CLIP (IF USED) OR CIRCUIT BREAKER 1.59 F Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 2.62 Phone: 336.468.2851 800.288.2851 49 TYPE 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Austin Type 12 and Type 13 single door enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: • ABB Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. Flange-Mounted Disconnect Enclosures • Allen-Bradley Bulletin 1494V disconnect switches with flange-mounted variable depth operating mechanisms and Bulletin 1494V flange-mounted variable depth operating mechanisms for circuit breakers. (These enclosures will not accept Allen-Bradley Bulletin 1494F disconnect devices or Bulletin 1494D circuit breaker operators.) • Cutler-Hammer/Westinghouse Type C361 flange-mounted variable depth operating mechanisms with disconnect switches and Type C371 flange-mounted variable depth operating mechanisms for circuit breakers. • General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. • I-T-E Max-Flex flange-mounted variable depth operating handle for disconnect switches and circuit breakers. • Square D Class 9422 disconnect switches with flange-mounted variable depth operating mechanisms and Class 9422 flange-mounted variable depth operating mechanisms for circuit breakers. (These enclosures will not accept Square D Class 9422 bracket-mounted disconnect devices.) Catalog Number Enclosure Size AxBxC Panel Catalog Number Panel Size Ht. X Wd. Print Pocket AB-20228N/DSC AB-24228N/DSC AB-24268N/DSC AB-30228N/DSC AB-30268N/DSC AB-36268N/DSC AB-36328N/DSC AB-42328N/DSC AB-42388N/DSC AB-48388N/DSC AB-60388N/DSC 20x21.38x8 24x21.38x8 24x25.38x8 30x21.38x8 30x25.38x8 36x25.38x8 36x31.38x8 42x31.38x8 42x37.38x8 48x37.38x8 60x37.38x8 AB-2020TP AB-2420TP AB-2424TP AB-3020TP AB-3024TP AB-3624TP AB-3630TP AB-4230TP AB-4236TP AB-4836TP AB-6036TP 17x17 21x17 21x21 27x17 27x21 33x21 33x27 39x27 39x33 45x33 57x33 Small Small Small Small Large Large Large Small Large Large Large 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 AB-202210N/DSC AB-242210N/DSC AB-242610N/DSC AB-302210N/DSC AB-302610N/DSC AB-362610N/DSC AB-363210N/DSC AB-423210N/DSC AB-423810N/DSC AB-483810N/DSC AB-603810N/DSC 20x21.38x10 24x21.38x10 24x25.38x10 30x21.38x10 30x25.38x10 36x25.38x10 36x31.38x10 42x31.38x10 42x37.38x10 48x37.38x10 60x37.38x10 AB-2020TP AB-2420TP AB-2424TP AB-3020TP AB-3024TP AB-3624TP AB-3630TP AB-4230TP AB-4236TP AB-4836TP AB-6036TP 17x17 21x17 21x21 27x17 27x21 33x21 33x27 39x27 39x33 45x33 57x33 Small Small Small Small Large Large Large Small Large Large Large 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 AB-302612N/DSC AB-363212N/DSC AB-423212N/DSC AB-423812N/DSC AB-483812N/DSC AB-603812N/DSC 30x25.38x12 36x31.38x12 42x31.38x12 42x37.38x12 48x37.38x12 60x37.38x12 AB-3024TP AB-3630TP AB-4230TP AB-4236TP AB-4836TP AB-6036TP 27x21 33x27 39x27 39x33 45x33 57x33 Large Large Small Large Large Large 0 0 1 1 1 1 0 1 1 1 1 1 AB-363216N/DSC AB-483816N/DSC AB-603816N/DSC 36x31.38x16 48x37.38x16 60x37.38x16 AB-3630TP AB-4836TP AB-6036TP 33x27 45x33 57x33 Large Large Large 0 1 1 1 1 1 INDUSTRY STANDARDS UL 508 Type 12 CUL Type 12 NEMA Type 12 Stiffener Door/Body Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Disconnect Ordering Information: Allen-Bradley When using a Bulletin 1494F flange-mounted disconnect switch, order: – A disconnect switch with operating mechanism (Bulletin 1494V) – Bulletin 1494V-H1 operating handle – A connecting rod [Bulletin 1494V-RA1 for 8" and 10" deep enclosures; Bulletin 1494V-RA2 for 12" and 16" deep enclosures] – A trailer fuse block kit, if required (Bulletin 1494V) – A fuse clip kit, if required – Line and load connectors, if required – Door hardware (Bulletin 1494V-L1 for 2-point latching or Bulletin 1494V-L1 and 1494V-L2 for 3-point latching) When using a Bulletin 1494V circuit breaker operating mechanism, order: – A circuit breaker (C-H/Westinghouse) – A circuit breaker operating mechanism (Bulletin 1494V) – An operating handle (Bulletin 1494V-H11) – A connecting rod [Bulletin 1494V-RA1 for 8" and 10" deep enclosures or Bulletin 1494V-RA2 for 12" and 16" deep enclosures] – Door hardware (Bulletin 1494V-L1 for 2-point latching, or Bulletin 1494V-L1 and 1494V-L2 for 3-point latching) ABB Controls When using a disconnect switch, order: – A flange operated switch (fusible or non-fusible) – A shaft [DSFHS-12 for 8", 10", and 12" deep enclosures or DSFHS-17 for 16” deep enclosures] – A handle (DSFGN-HS12) – Door hardware (FH-DHK for 2-point latching or FH-DHK and FH-3RL for 3-point latching) When using a circuit breaker, order: – A circuit breaker (ABB) – An operating mechanism – A shaft [FHS-12 for 8", 10", and 12" deep enclosures or FHS-17 for 16” deep enclosures] – A handle mechanism (FHN-HS12) – Door hardware (FH-DHK for 2-point latching or FH-DHK and FH-3RL for 3-point latching) Cutler-Hammer/Westinghouse When using a Type C361 disconnect switch, order: – A disconnect switch with an operating mechanism – An operating handle (C361H1 or C361H3) – Door hardware (C361KJ4 or C361KJ6 and C361KR for 3-point latching) When using a Type C371 circuit breaker operating mechanism with a C-H/Westinghouse circuit breaker, order: – A circuit breaker – An operating mechanism – An operating handle – Door hardware (C361KJ4 or C361KJ6 for 2-point latching, C361KJ4 or C361KJ6 and C361KR for 3-point latching) When using a C-H/Westinghouse circuit breaker with a Flex Shaft handle mechanism, order: – A circuit breaker – A complete Flex Shaft handle mechanism – Door hardware (C361KJ4 or C361KJ6 for 2-point latching, C361KJ4 or C361KJ6 and C361KR for 3-point latching) General Electric When using a disconnect switch, order: – A disconnect switch (Type QMR or QMW) – A fuse clip or no-fuse kit – A flange handle (STDA1 or STDA2) – A variable depth operating mechanism – Door hardware (TDV1 for 2-point latching or TDV1 and TDV3 for 3-point latching) When using a circuit breaker with a Spectra Flex cable operator, order: – A circuit breaker – A flange-mounted handle mechanism – A breaker-mounted mechanism – An operating cable – Door hardware (TDV1 for 2-point latching or TDV1 and TDV3 for 3-point latching) Flange-Mounted Disconnect Enclosures When ordering wall-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. When using a circuit breaker, order: – A circuit breaker – A flange handle (STDA1 or STDA2) – A variable depth operating mechanism – Door hardware (TDV1 for 2-point latching or TDV1 and TDV3 for 3-point latching) I-T-E Siemens When using a disconnect switch, order: – A basic switch (right hand) – A fuse or no-fuse kit – FHOHS flange-mounted handle – Switch operator – Cable, 36" – Door hardware (DKR2 for 2-point latching or DKR3 for 3-point latching) When using a circuit breaker, order: – A circuit breaker – Pressure wire connectors – FHOH flange-mounted handle – A circuit breaker operator mechanism – An operating cable (standard 36" for 125 amp to 600 amp circuit breakers and 48" for 800 amp to 1200 amp circuit breakers) – Door hardware (DKR2 for 2-point latching or DKR3 for 3-point latching) Square D When using a Class 9422 disconnect switch, order: – A disconnect switch with operating mechanism (Class 9422) – A handle mechanism (Class 9422 Type A-1) – A door closing mechanism (Class 9423 Type M4 for 2-point latching, or Class 9423 Type M9 or M4 and Class 9423 Type M3 for 3-point latching) When using a circuit breaker, order: – A circuit breaker (Square D) – An operating mechanism (Class 9422) – A handle mechanism (Class 9423 Type M4 for 2-point latching, or Class Type M9 or M4 and Class 9423 Type M3 for 3-point latching) When using a Class 9422 Type “T” disconnect switch with a cable mechanism, order: – A disconnect switch with operating mechanism (Class 9422, Type T) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT_O) 3-, 5-, or 10-foot – A door closing mechanism (Class 9423 Type M4 for 2-point latching, or Class 9423 Type M9 or M4 and Class 9423 Type M3 for 3-point latching) When using a circuit breaker with a cable mechanism, order: – A circuit breaker (Square D) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT_O) 3-, 5-, or 10-foot – A door closing mechanism (Class 9423 Type M4 for 2-point latching, or Class 9423 Type M9 or M4 and Class 9423 Type M3 for 3-point latching) Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 51 TYPE 4, 4X SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Construction: • 14 gauge steel or 14 gauge Type 304 stainless steel. Flange-Mounted Disconnect Enclosures • Seams are continuously welded and ground smooth. • External mounting feet. • Door and body stiffeners in larger enclosures for rigidity. • Formed lip around all sides of enclosure opening excludes liquids and contaminants. • Stainless steel exterior hardware. • Stainless steel door clamps on three sides of door provide a watertight seal. • Door removable by pulling continuous hinge pin. • Print pocket included. • Oil-resistant gasket. Finish: Type 4 enclosures are painted ANSI 61 gray polyester powder outside and inside. Type 4X enclosures are unpainted. Optional panels are painted white polyester powder. • 3/8-16 threaded collar studs provided for mounting optional panel. • Holes in body for mounting disconnect operating handle and operating mechanism • Cover interlock bracket welded to door. INDUSTRY STANDARDS Steel UL 508 Types 4 & 12 CUL Types 4 & 12 NEMA Types 4, 12, & 3 • Disconnect switch, operating handle, and operating mechanism are not furnished with the enclosure. They must be ordered separately from the disconnect manufacturer. Stainless Steel UL 508 Types 4X, 4, & 12 CUL Types 4X, 4, & 12 NEMA Types 4X, 4, 12, & 3 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS OMIT TWO MIDDLE STUDS IF "B" IS LESS THAN 32" B .62 3.00 C 3.00 X STIFFENER S S PANEL (ORDERED SEPARATELY) A Flange-Mounted Disconnect Enclosures .44 DIA. A-3.00 DOOR CLAMP B-4 3/8 IF "A" IS LESS THAN 31" X .62 .44 SECTION X-X MOUNTING DOOR STIFFENER CONTINUOUS HINGE OMIT TWO MIDDLE STUDS FEET DOOR STIFFENER 2.75 1.38 NEOPRENE GASKET 3/8-16 COLLAR STUD SPACE OCCUPIED BY DISCONNECT MOUNTING FEET BODY STIFFENER SECTION S-S NOTE: D = 8.62 WHEN C = 8.00 PANEL (ORDERED SEPARATELY) D = 11.62 WHEN C = 12.00 W = WIRING SPACE 1.50 W D CL TOP HOLE IN R.H. FLANGE E THIS SPACE IS OCCUPIED BY DISCONNECT SWITCH AND FUSE CLIP (IF USED) OR CIRCUIT BREAKER 1.59 F Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 2.62 Phone: 336.468.2851 800.288.2851 53 TYPE 4, 4X SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Austin Type 4 and Type 4X single door enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: Flange-Mounted Disconnect Enclosures • ABB Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. • Allen-Bradley Bulletin 1494V disconnect switches with flange-mounted variable depth operating mechanisms and Bulletin 1494V flange-mounted variable depth operating mechanisms for circuit breakers. (These enclosures will not accept Allen-Bradley Bulletin 1494F disconnect devices Bulletin 1494D circuit breaker operators.) or • Cutler-Hammer/Westinghouse Type C361 flange-mounted variable depth operating mechanisms with disconnect switches and Type C371 flange-mounted variable depth operating mechanisms for circuit breakers. • General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. • I-T-E Max-Flex flange-mounted variable depth operating handle for disconnect switches and circuit breakers. • Square D Class 9422 disconnect switches with flange-mounted variable depth operating mechanisms and Class 9422 flange-mounted variable depth operating mechanisms for circuit breakers. (These enclosures will not accept Square D Class 9422 bracket-mounted disconnect devices.) Catalog Number Stainless Steel Catalog Number Enclosure Size AxBxC Panel Catalog Number Panel Size Ht.xWd. Print Pocket No. of Clamps AB-24228NF/DSC AB-24268NF/DSC AB-30268NF/DSC AB-36268NF/DSC AB-36328NF/DSC AB-24228NFX/DSC AB-24268NFX/DSC AB-30268NFX/DSC AB-36268NFX/DSC AB-36328NFX/DSC 24x21.38x8 24x25.38x8 30x25.38x8 36x25.38x8 36X31.38X8 AB-2420TP AB-2424TP AB-3024TP AB-3624TP AB-3630TP 21x17 21x21 27x21 33x21 33x27 Small Small Large Large Large 6 6 9 9 9 0 0 0 0 0 0 0 0 0 1 AB-423212NF/DSC AB-423812NF/DSC AB-483812NF/DSC AB-603812NF/DSC AB-423212NFX/DSC AB-423812NFX/DSC AB-483812NFX/DSC AB-603812NFX/DSC 42x31.38x12 42x37.38x12 48x37.38x12 60x37.38x12 AB-4230TP AB-4236TP AB-4836TP AB-6036TP 39x27 39x33 45x33 57x33 Small Large Large Large 9 9 10 13 1 1 1 1 1 1 1 1 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Stiffener Door/Body Phone: 336.468.2851 800.288.2851 D I S C O N N E C T O R D E R I N G I N F O R M AT I O N When ordering wall-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. When using a Bulletin 1494V circuit breaker operating mechanism, order: – A circuit breaker (C-H/Westinghouse) – A circuit breaker operating mechanism (Bulletin 1494V) – An operating handle (Bulletin 1494V-W11) – A connecting rod [Bulletin 1494V-RA1 for 8" deep enclosures; Bulletin 1494V-RA2 for 12" deep enclosures] ABB Controls When using a disconnect switch, order: – A flange-operated switch (fusible or non-fusible) – A shaft (DSFHS-12) – A handle (DSFHN-HS4) When using a circuit breaker, order: – A circuit breaker (ABB) – An operating mechanism – A shaft (FHS-12) – A handle (FHN-HS4) Cutler-Hammer/Westinghouse When using a Type C361 disconnect switch, order: – A disconnect switch with an operating mechanism – An operating handle (C361H2 or C361H4) When using a Type C371 circuit breaker operating mechanism with a C-H/Westinghouse circuit breaker, order: – A circuit breaker – An operating mechanism – An operating handle (C371H2 or C371H4) When using a C-H/Westinghouse circuit breaker with Type 4/4X Flex Shaft handle mechanism, order: – A circuit breaker – A complete Flex Shaft handle mechanism General Electric When using a disconnect switch, order: – A disconnect switch (QMR or QMW) – A fuse clip kit or no-fuse kit – A flange handle (STDA1X) – A variable depth operating mechanism Flange-Mounted Disconnect Enclosures Allen-Bradley When using a Bulletin 1494V disconnect switch, order: – A disconnect switch with operating mechanism (Bulletin 1494V) – An operating handle (Bulletin 1494V-W1) – A connecting rod [Bulletin 1494V-RA1 for 8” deep enclosures; Bulletin 1494V-RA2 for 12" deep enclosures] – A trailer fuse block kit, if required (Bulletin 1494V) – A fuse clip kit, if required – Line and load connectors, if required When using a circuit breaker, order: – A circuit breaker – A flange handle (STDA1X) – A variable depth operating mechanism When using a circuit breaker with a Spectra Flex cable operator, order: – A circuit breaker – A flange-mounted handle mechanism – A breaker-mounted mechanism – An operating cable I-T-E Siemens When using a disconnect switch, order: – A basic switch (right hand) – A fuse or non-fuse kit – A flange-mounted handle (FHOHS4) – Switch operator – Cable, 36' When using a circuit breaker, order: – A circuit breaker – Pressure wire connectors – A flange-mounted handle (FHOHS4) – A circuit breaker operator mechanism – An operating cable (standard 36") Square D When using a Class 9422 disconnect switch, order: – A disconnect switch with operating mechanism (Class 9422) – A handle mechanism (Class 9422 Type A-2 or A-1) When using a circuit breaker, order: – A circuit breaker (Square D) – An operating mechanism (Class 9422) – A handle mechanism (Class 9422 Type A-2 or A-1) When using a Class 9422 Type “T” disconnect switch with a cable mechanism, order: – A disconnect switch with operating mechanism (Class 9422, Type T) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT-O) 3-, 5-, or 10-foot When using a circuit breaker with a cable mechanism, order: – A circuit breaker – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT_O) 3-, 5-, or 10-foot Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 55 TYPE 4, 4X, 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Wire Bend Space Above Disconnect Allen-Bradley Bulletin 1494V Disconnects Flange-Mounted Disconnect Enclosures Type Number When C=8 W Type 12 When When C = 10 C = 12 or 16 W W Type 4 & 12 When When C=8 C = 12 W W Amp Rating Fuse Clip Fuse Class Space Occupied E F* DS30 DS30 DS30 DS30 DS30 DS30 DS30 30A 30A 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 30A-600V 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R J H,K H,K J 3.88 5.25 8.00 5.25 6.00 8.50 5.38 6.62 6.62 6.62 6.62 6.62 6.62 6.62 2.88 2.88 2.88 2.88 2.88 2.88 2.88 5.25 5.25 5.25 5.25 5.25 5.25 5.25 9.75 9.75 9.75 9.75 9.75 9.75 9.75 6.75 6.75 6.75 6.75 6.75 6.75 6.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 DS60 DS60 DS60 DS60 DS60 DS60 DS60 DS60 60A 60A 60A 60A 60A 60A 60A 60A NO FUSE 60A-250V 60A-600V 60A-600V 30A-600V 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J H,K,R H,K H,K J 3.88 6.00 8.50 5.38 8.00 8.50 10.50 7.25 6.62 6.62 6.62 6.62 6.62 6.62 6.62 6.62 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 5.12 5.12 5.12 5.12 5.12 5.12 5.12 5.12 9.62 9.62 9.62 9.62 9.62 9.62 9.62 9.62 6.62 6.62 6.62 6.62 6.62 6.62 6.62 6.62 9.62 9.62 9.62 9.62 9.62 9.62 9.62 9.62 DS100** DS100** DS100** DS100** DS100** DS100** 100A 100A 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V 60A-600V 60A-600V NA H,K,R H,K,R J H,K,R J 3.88 8.12 10.12 6.88 10.12 8.88 6.62 6.62 6.62 6.62 6.62 6.62 NA NA NA NA NA NA 5.12 5.12 5.12 5.12 5.12 5.12 9.62 9.62 9.62 9.62 9.62 9.62 6.44 6.44 6.44 6.44 6.44 6.44 9.62 9.62 9.62 9.62 9.62 9.62 DS200** DS200** DS200** DS200** DS200** DS200** 200A 200A 200A 200A 200A 200A NO FUSE 200A-250V 200A-600V 200A-600V 100A-600V 100A-600V NA H,K,R H,K,R J H,K,R J 4.75 10.88 13.38 9.50 12.00 8.75 7.88 7.88 7.88 7.88 7.88 7.88 NA NA NA NA NA NA NA NA NA NA NA NA 8.12 8.12 8.12 8.12 8.12 8.12 NA NA NA NA NA NA 8.12 8.12 8.12 8.12 8.12 8.12 M40 15A-150A Westinghouse Circuit Breakers EHD, FD, FDB FDC, HFD, HMCP NA 5.00 4.50 4.25 6.62 11.12 8.12 11.12 M50 70A-250A Westinghouse Circuit Breakers JD, JDB, JDC, HJD, HMCP NA 9.75 4.75 NA NA 10.62 NA 10.62 M60 100A-400A Westinghouse Circuit Breakers KD, KDB, KDC HKD, HMCP NA 9.69 6.12 NA NA 10.50 NA 10.50 *Does not include space for optional auxiliary switch . **Series B Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Flange-Mounted Disconnect Enclosures DISCONNECT WIRING S PA C E I N F O R M AT I O N Wire Bend Space Above Disconnect ABB Controls Disconnect Switches with Flange-Mounted Operators Switch Number Space Occupied E F When C=8 W Type 12 When When C = 10 C = 12 or 16 W W Type 4 & 12 When When C=8 C = 12 W W Amp Rating Fuse Clip Fuse Class OETL-NF30-F OETL-NF60-F OETL-NF100-F OETL-NF175-F OETL-NF200-F 40A 80A 100A 175A 200A NO FUSE NO FUSE NO FUSE NO FUSE NO FUSE NA NA NA NA NA 4.45 4.86 4.86 7.30 7.36 3.78 3.78 4.78 6.49 7.28 6.41 6.22 5.66 NA NA 8.75 8.56 8.00 5.75 5.75 13.28 13.09 12.53 10.28 10.28 10.28 10.09 9.53 7.28 7.28 13.28 13.09 12.53 10.28 10.28 OESA-F30J6-F OESA-F60J6-F OESA-F100J6-F 30A 60A 100A 30A-600V 60A-600V 100A-600V J J J 4.28 4.28 6.54 6.58 6.26 7.65 4.73 4.73 4.30 7.07 7.07 6.64 11.61 11.61 11.17 8.61 8.61 8.17 11.61 11.61 11.17 Wire Bend Space Above Disconnect ABB Controls Circuit Breakers with Flange-Mounted Operators Mechanism FHD-M FHF-M FHF-M FHJ-M FHM-M FHM-M Amp Rating Frame Type 150A 150A-225A 225A 400A 600A 800A D E/Q F J L M Space Occupied E F 6.92 5.98 7.44 9.71 8.28 10.11 3.94 4.23 4.23 5.62 11.26 11.26 When C=8 W 5.29 3.84 3.84 NA NA NA Type 12 When When C = 10 C = 12 or 16 W W 7.64 6.19 6.19 NA NA NA 12.17 10.72 10.72 8.77 8.28 7.87 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4 & 12 When When C=8 C = 12 W W 9.17 7.72 7.72 NA NA NA 12.17 10.72 10.72 8.77 8.28 7.87 Phone: 336.468.2851 800.288.2851 57 TYPE 4, 4X, 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Wire Bend Space Above Disconnect Flange-Mounted Disconnect Enclosures Cutler-Hammer C361 Disconnect Switches Switch Number When C=8 W Space Occupied E F Type 12 When When C = 10 C = 12 or 16 W W Type 4 & 12 When When C=8 C = 12 W W Type Number Amp Rating Fuse Clip Fuse Class C361 C361 C361 C361 NC SC21 SC61 SC61 30A 30A 30A 30A NO FUSE 30A-250V 60A-250V 30A-600V NA H,K,R H,K,R H,J,K,R 5.75 8.38 8.38 8.38 7.43 7.43 7.43 7.43 3.44 3.44 3.44 3.44 5.75 5.75 5.75 5.75 10.31 10.31 10.31 10.31 7.31 7.31 7.31 7.31 10.31 10.31 10.31 10.31 C361 C361 C361 C361 C361 ND SD22 SD22 SD62 SD62 60A 60A 60A 60A 60A NO FUSE 60A-250V 30A-600V 60A-600V 60A-600V NA H,K,R J H,K,R J 5.75 8.38 8.38 8.38 8.38 7.43 7.43 7.43 7.43 7.43 3.44 3.44 3.44 3.44 3.44 5.75 5.75 5.75 5.75 5.75 10.31 10.31 10.31 10.31 10.31 7.31 7.31 7.31 7.31 7.31 10.31 10.31 10.31 10.31 10.31 C361 C361 C361 C361 NE SE263 SE263 SE263 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J 5.56 10.31 10.31 10.31 8.95 8.95 8.95 8.95 3.00 3.00 3.00 3.00 5.38 5.38 5.38 5.38 9.91 9.91 9.91 9.91 7.47 7.47 7.47 7.47 9.91 9.91 9.91 9.91 C361 C361 C361 NF* SF264* SF264* 200A 200A 200A NO FUSE 200A-250V 200A-600V NA H,K,R H,J,K,R 13.06 13.06 13.06 10.00 10.00 10.00 NA NA NA NA NA NA 7.94 7.94 7.94 4.94 4.94 4.94 7.94 7.94 7.94 . Wire Bend Space Above Disconnect Cutler-Hammer C371 Circuit Breaker Operators for C-H / Westinghouse Circuit Breakers Mechanism Space Occupied E F When C=8 W Type 12 When When C = 10 C = 12 or 16 W W Type 4 & 12 When When C=8 C = 12 W W Max Amp Rating Frame Type C371E C371E 225A 150A F-Frame: EHD, FDB, FD, HFD, FDC F-Frame: HMCP 6.00 6.00 5.50 5.50 4.44 4.44 6.81 6.81 11.44 11.44 8.44 8.44 11.44 11.44 C371F C371F 250A 250A J Frame: JDB, JD, HJD, JDC J Frame: HCMP 8.94 10.94 8.00 8.00 NA NA 6.75 6.75 11.25 11.25 NA NA 11.25 11.25 C371F C371F 400A 400A K Frame: DK, KDB, KD, HKD K Frame: HMCP 9.75 9.75 8.00 8.00 NA NA NA NA 10.75 10.75 NA NA 10.75 10.75 C371G C371G 600A 600A L Frame: LD, HLD, LDC L Frame: HMCP 8.44 8.44 11.88 11.88 NA NA NA NA 9.18 9.18 NA NA 9.18 9.18 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 DISCONNECT WIRING S PA C E I N F O R M AT I O N Complete Operator Mechanism Amp Rating Frame Type Breaker Height Breaker Width F1S03 F1S03 225A 150A F-Frame/EHD, FDB, FD, HFD, FDC F-Frame HMCP 6.00 6.00 4.12 4.12 F2S03 F2S03 250A 250A J-Frame/JDB, JD, HJD, JDC J-Frame HMCP 10.00 10.00 4.12 4.12 F3S03 F3S03 400A 400A K-Frame/DK, KDB, KD, HKD K-Frame HMCP 10.12 12.45 5.50 5.50 F4S03 F4S03 600A 600A L-Frame/LD, HLD, LDC L-Frame HMCP 10.75 12.50 8.25 8.25 F7S04 800A M-Frame/MD, MDS 16.00 8.25 F5S04 1200A N-Frame/ND, HND, NDC 16.00 8.25 F6S04 2500A R-Frame/RD, CRD, RDC 16.00 15.50 Flange-Mounted Disconnect Enclosures Cutler-Hammer Flex Shaft Operator Mechanisms for C-H/Westinghouse Circuit Breakers -Catalog numbers for complete mechanisms include a flange-mounted handle, flexible shaft and circuit breaker mechanism. -The last digit of the catalog number denotes the length of shaft (F1S03 = 3 foot shaft). The F, J, K frame Flex Shafts are available in 3-foot to 10-foot lengths. The L, N, R frame Flex Shafts are available in 4-foot to 6-foot lengths. Space Occupied by Disconnect *The Flex Shaft system allows the circuit breaker to be positioned independent from the flange-mounted handle mechanism. *Refer to National Electrical Code 1999, article 430-10(b) for wiring space "W" required for line side conductors. *Choose the length of shaft based on placement of the circuit breaker in the enclosure ensuring a 4" minimum bending radius for the Flex Shaft. *Space occupied by circuit breaker is determined by overall height "X", width "Y", wire bend space "W" and location "F" as selected from right to left. Wire Bend Space Above Disconnect General Electric Type STDA Operators for Disconnects Mechanism Type 12 When When C = 10 C = 12 or 16 W W Type 4 & 12 When When C=8 C = 12 W W Space Occupied E F When C=8 W NA H,R H,R H,R H,R 7.75** 7.75** 12.38** 12.38** 12.38** 5.25 5.25 5.25 5.25 5.25 6.18* 6.18* 6.18* 6.18* 6.18* 7.62 7.62 7.62 7.62 7.62 12.12 12.12 12.12 12.12 12.12 9.12 9.12 9.12 9.12 9.12 12.12 12.12 12.12 12.12 12.12 NO FUSE 60A-250V 60A-600V 100A-250V 100A-600V NO FUSE 100A-250V 100A-600V 200A-250V 200A-600V NA H,R H,R H,R H,R NA H,R H,R H,R H,R 7.75** 12.38** 12.38** 12.38** 12.38** 7.75** 12.38** 12.38** 12.38** 12.38** 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 6.18* 6.18* 6.18* 6.18* 6.18* 6.18* 6.18* 6.18* 6.18* 6.18* 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 12.12 12.12 12.12 12.12 12.12 12.12 12.12 12.12 12.12 12.12 9.12 9.12 9.12 9.12 9.12 9.12 9.12 9.12 9.12 9.12 12.12 12.12 12.12 12.12 12.12 12.12 12.12 12.12 12.12 12.12 NO FUSE 200A-250V 200A-600V NA H,R H,R 7.00 15.38 15.38 9.12 9.12 9.12 NA NA NA NA NA NA 9.50 9.50 9.50 6.50 6.50 6.50 9.50 9.50 9.50 Amp Rating Fuse Clip Fuse Class TD0M1A TD0M1A TD0M1B TD0M1B TD0M1B 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 60A-250V 60A-600V TD0M1A TD0M1B TD0M1B TD0M1B TD0M1B TD0M1A TD0M1B TD0M1B TD0M1B TD0M1B 60A 60A 60A 60A 60A 100A 100A 100A 100A 100A TD0M2 TD0M2 TD0M2 200A 200A 200A *Disconnect moved down .88" to fit on panel **Dimension applies to 8" deep enclosures and is .88" less in deeper enclosures Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 59 TYPE 4, 4X, 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Wire Bend Space Above Disconnect General Electric Type STDA Operators for Circuit Breakers Mechanism Space Occupied E F When C=8 W Type 12 When When C = 10 C = 12 or 16 W W Type 4 & 12 When When C=8 C = 12 W W Flange-Mounted Disconnect Enclosures Amp Rating Frame Type SD0M1A SD0M1A TD0M1B TD0M1B TD0M1C TD0M1D TD0M3 TD0M3 TD0M4 TD0M4 TD0M5 150A 150A 150A 150A 150A 150A 225A 225A 400A 600A 400A TEB, TED, THED TEC TB1 TEC, TECL TEL THLC1 TFJ TFK, THFK, TFL TJJ, TJK4, THJK4, TJL4V TJK6, THJK6, TJ4V, TJL4V TB4, TJH6S 7.75** 7.75** 12.38** 12.38** 7.75** 7.75** 10.38 10.38 8.25 8.25 14.25 5.25 5.25 5.25 5.25 5.25 5.25 5.75 5.75 9.38 9.38 9.38 6.06* 6.06* 6.06* 6.06* 6.06* NA NA NA NA NA NA 7.50 7.50 7.50 7.50 7.50 5.12 6.06 6.06 5.12 5.12 5.12 12.06 12.06 12.06 12.06 12.06 9.62 10.62 10.62 9.69 9.69 9.69 9.06 9.06 9.06 9.06 9.06 6.62 7.62 7.62 6.69 6.69 6.69 12.06 12.06 12.06 12.06 12.06 9.62 10.62 10.62 9.69 9.69 9.69 TD0M6 TD0M6 225A 400A TLB2, THLC2 TLB4, THLC4 11.75 11.75 9.38 9.38 NA NA NA NA 9.12 7.75 6.12 4.75 9.12 7.75 SD0M1A SD0M3 SD0M4 150A 250A 600A SPECTRA SE150 SPECTRA SF250 SPECTRA SG600 7.75** 10.38 10.00 5.25 5.75 7.00 6.06* NA NA 7.50 6.06 NA 12.06 10.62 7.93 9.06 7.06 NA 12.06 10.06 7.93 *Disconnect moved down .88" to fit on panel. **Dimension applies to 8" deep enclosures and is .88" less in deeper enclosures. General Electric Circuit Breakers with Spectra Flex Cable Operators Frame Size Max Amp Rating Circuit Breaker Height "X" Circuit Breaker Width "Y" E150 SE150 150A 150A 6.31 6.31 4.12 4.12 SF250 250A 10.12 4.12 SG600 600A 10.09 5.50 SK1200 1200A 15.50 8.25 Breaker Mechanism Flange-Mounted Handle Operating Cable SC0M1A SC0M1EF SC0M1G SC0M1K SCH1 SCH1 SCH1 SCH2K SC3L SC3L SC3L SC3H See enclosure size tables for enclosures that will accept these devices Frame Size E150 SE150/SF250 SG600 SK1200 *Operating cables are available in 3-foot to 10-foot lengths. (The number 3 in the catalog number denotes 3-foot cable.) **Add "X" for NEMA 4 or 4X flange mounted handle. Space Occupied by Circuit Breaker -The General Electric Spectra-Flex cable operators allow a circuit breaker to be positioned independent from the flange-mounted handle mechanism. -Refer to National Electrical Code 1999 article 430-10(b) for wiring space "W" required for line side conductors. -Choose the operating cable length based on placement of circuit breaker in the enclosure ensuring a 3" minimum bending radius for the cable. -Space occupied by circuit breaker is determined by overall circuit breaker size ("X" heigth and "Y" width) plus "W" wire bend space and location "F" from right to left as selected. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 DISCONNECT WIRING S PA C E I N F O R M AT I O N Switch Amp Rating Fuse Clip Fuse Class Disconnect Height "X" Disconnect Width "Y" MCS603R MCS603R MCS603R MCS603R 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 30A-600V NA H,K,R H,K,R J 5.52 8.11 10.11 8.48 6.13 6.13 6.13 6.13 MCS606R MCS606R MCS606R MCS606R 60A 60A 60A 60A NO FUSE 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R J 5.52 7.86 10.38 8.36 6.13 6.13 6.13 6.13 MCS610R MCS610R MCS610R MCS610R 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J 7.59 11.85 13.85 10.60 7.38 7.38 7.38 7.38 MCS620R MCS620R MCS620R MCS620R 200A 200A 200A . 200A NO FUSE 200A-250V 200A-600V 200A-600V NA H,K,R H,K,R J 9.02 14.70 17.20 13.32 9.17 9.17 9.17 9.17 Flange-Mounted Disconnect Enclosures I-T-E Disconnect Switches for Max-Flex Operators See enclosure size table for enclosures that accept these devices I-T-E Circuit Breakers with Max-Flex Operators Complete (1) (2) Operator Mechanism Circuit Breaker Frame Maximum Amp Rating Circuit Breaker Height "X" Circuit Breaker Width "Y" Circuit Breaker Type FH0E036 FH0E36 ED CED 125A 125A 6.34 9.58 3.00 3.00 ED2, ED4, ED6, HED4, HED6 CED6 FH0F036 FH0J036 FD CFD 250A 250A 9.50 14.25 4.50 4.50 FXD6-A, FD6-A, HFD6. FXD6-ETJ, HHFD6, HHFXD6 CFD6, CFD6-ETI FH0J036 FH0J036 JD CJD 400A 400A 11.00 17.86 7.50 7.50 JXD2, JXD6, JD6, HJD6, HHJD6, HHJXD6, JXD6-ETI CJD6, CJD6-ETI FH0J036 FH0J036 LD CLD 600A 600A 11.00 17.86 7.50 7.50 LXD6, LD6, HLD6, HHLD6, HHLDX6, LXD6-ETI CLD6, CLD6-ETI FH0LM036 LMD 800A 16.00 9.00 LMD6, LMXD6, HLMD6, HLMXD6, LMXD6-ETI . 1)The last 3 digits of operator mechanism number indicate cable length in inches. 48" cables are available for ED, FD, JD/LD operators and 60" cables for MD/ND, PD/RD operators 2) For Type 4 applications order handle, cable and circuit breaker operator separately. Space Occupied by Disconnect -The I-T-E Max-Flex cable system allows the disconnect to be positioned independent from the flange-mounted handle operator. . -Refer to National Electrical Code 1999 article 430-10(b) for wiring space "W" required for line side conductors. -Refer to Siemens I-T-E installation instructions for limits on disconnect location when using 36" or 48" Max-Flex cables -Space occupied by disconnect is determined by overall disconnect height "X", width "Y", wire bend space "W", and location "F" as selected from right to left. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 61 TYPE 4, 4X, 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Square D Class 9422 Disconnect Switches used with Cable Mechanism 9422-CFT30* and 9422A-1 Handle Mechanism Switch Flange-Mounted Disconnect Enclosures Amp Rating Fuse Clip Fuse Class Disconnect Height "X" Disconnect Width "Y" TCN-30 TCF-30 TCF-33 TCF-33 TCF-33 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 60A-250V 30A-600V NA H,K,R H,K,R H,K,R J 5.90 7.50 10.15 8.15 7.50 6.20 6.20 6.20 6.20 6.20 TDN-60 TDF-60 TDF-60 TDF-63 TDF-63 60A 60A 60A 60A 60A NO FUSE 30A-600V 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R H,K,R J 5.90 10.15 8.15 10.65 7.50 6.20 6.20 6.20 6.20 6.20 TEN-10 TEF-10 TEF-10 TEF-10 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J 5.90 10.35 12.35 10.35 6.20 6.20 6.20 6.20 See enclosure size table for enclosures that accept these devices. *Use switch with appropriate cable mechanism and 9422-A1 handle mechanism . Square D Class 9422 Cable Mechanisms for Circuit Breakers Cable Type* Switch 9422 CGJ30 9422 CEJ30 9422 CFA30 9422 CKA30 9422 CLA30 Amp Rating Frame Type Circuit Breaker Height "X" Circuit Breaker Width "Y" 75A 100A 100A 250A 400A GJL GJL FAL, FHL KAL, KHL LAL, LHL, Q4L 4.75 4.75 6.00 8.00 11.00 3.50 3.50 4.50 4.50 6.00 See enclosure size table for enclosures that accept these devices. Use cable mechanism with appropriate circuit breaker and 9422-A1 handle mechanism. *Cable operators are available in 3, 5, and 10 foot lengths. Numbers shown (30) are for 3 foot cables. Space Occupied by Disconnect Switch or Circuit Breaker -Square D cable mechansims allow disconnect device to be positioned independent from the flange mounted handle mechanism. -Refer to National Electrical Code 1999 article 430-10(b) for wiring space "W" required for line side conductors. -Choose cable mechanism length based on placement of disconnect in enclosure. See Square D Instruction Bulletin for minimum bend radius for cable. -Space occupied by disconnect is determined by overall disconnect ("X" height and "Y" width) plus "W" wire bend space and location "F" from right to left as selected. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 DISCONNECT WIRING S PA C E I N F O R M AT I O N Square D Class 9422 Disconnects Type Number Space Occupied E F When C=8 W Type 12 When When C = 10 C = 12 or 16 W W Type 4 & 12 When When C=8 C = 12 W W Amp Rating Fuse Clip Fuse Class TCN-30 TCF-30 TCF-33 TCF-33 TCF-33 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 60A-250V 30A-600V NA H,K,R H,K,R H,K,R J 3.80 5.53 8.15 6.15 5.53 6.84 6.84 6.84 6.84 6.84 3.69 3.69 3.69 3.69 3.69 6.03 6.03 6.03 6.03 6.03 10.56 10.56 10.56 10.56 10.56 7.56 7.56 7.56 7.56 7.56 10.56 10.56 10.56 10.56 10.56 TDN-60 TDF-60 TDF-60 TDF-63 TDF-63 60A 60A 60A 60A 60A NO FUSE 30A-600V 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R H,K,R J 3.80 8.15 6.15 8.65 5.53 6.84 6.84 6.84 6.84 6.84 3.69 3.69 3.69 3.69 3.69 6.03 6.03 6.03 6.03 6.03 10.56 10.56 10.56 10.56 10.56 7.56 7.56 7.56 7.56 7.56 10.56 10.56 10.56 10.56 10.56 TEN-10 TEF-10 TEF-10 TEF-10 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J 3.80 8.25 10.25 7.05 6.84 6.84 6.84 6.84 NA NA NA NA 5.91 5.91 5.91 5.91 10.44 10.44 10.44 10.44 7.44 7.44 7.44 7.44 10.44 10.44 10.44 10.44 TC-1 TC-2 TC-3 TC-3 TC-3 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 60A-250V 30A-600V NA H,K,R H,K,R H,K,R J 5.75 5.75 7.75 5.88 5.75 6.00 6.00 6.00 6.00 6.00 3.12 3.12 3.12 3.12 3.12 5.12 5.12 5.12 5.12 5.12 9.62 9.62 9.62 9.62 9.62 6.62 6.62 6.62 6.62 6.62 9.62 9.62 9.62 9.62 9.62 TD-1 TD-2 TD-2 TD-3 TD-3 60A 60A 60A 60A 60A NO FUSE 30A-600V 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R H,K,R J 6.38 8.50 6.50 9.00 6.38 6.62 6.62 6.62 6.62 6.62 3.62 3.62 3.62 3.62 3.62 6.00 6.00 6.00 6.00 6.00 10.50 10.50 10.50 10.50 10.50 7.50 7.50 7.50 7.50 7.50 10.50 10.50 10.50 10.50 10.50 TE-1 TE-2 TE-2 TE-2 TE-3 100A 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V 200A-600V NA H,K,R H,K,R J J 4.75 7.50 9.50 6.25 13.75 8.38 8.38 8.38 8.38 8.38 NA NA NA NA NA 5.75 5.75 5.75 5.75 5.75 10.25 10.25 10.25 10.25 10.25 NA NA NA NA NA 10.2 10.25 10.25 10.25 10.25 TF-1 TF-2 TF-2 TF-2 TF-3 200A 200A 200A 200A 200A NO FUSE 200A-250V 200A-600V 200A-600V 400A-600V NA H,K,R H,K,R J J 5.50 11.50 14.00 10.12 14.50 11.62 11.62 11.62 11.62 11.62 NA NA NA NA NA NA NA NA NA NA 8.88 8.88 8.88 8.88 8.88 NA NA NA NA NA 8.88 8.88 8.88 8.88 8.88 RG-1 RG-1 RN-1 RP-1 RR-1 75A 100A 100A 250A 400A GJL GJL FAL, FHL KAL, KHL LAL, LHL, Q4L Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker 3.53 3.53 5.12 7.12 7.62 3.74 3.74 5.25 5.62 8.75 3.59 3.59 3.75 4.25* NA 5.93 5.93 6.12 6.88 NA 10.47 10.47 10.62 11.37 7.00 7.47 7.47 7.62 8.38 NA 10.47 10.47 10.62 11.38 7.00 Flange-Mounted Disconnect Enclosures Wire Bend Space Above Disconnect *Not recommended except with #1 or smaller line conductors. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 63 TYPE 12 SINGLE DOOR ENCLOSURES FOR A-B FLANGE-MOUNTED DISCONNECTS Austin Type 12 and Type 13 single door enclosures for Allen-Bradley disconnects are designed to house Allen-Bradley Bulletin 1494F disconnect devices and Bulletin 1494D circuit breaker operators. Construction: Flange-Mounted Disconnect Enclosures • 14 gauge steel. • Seams are continuously welded and ground smooth. • External mounting feet. • Door and body stiffeners in larger enclosures for rigidity. • Formed lip around all sides of enclosure opening excludes liquids and contaminants. • Door removable by pulling continuous hinge pin. • Print pocket included. • Oil-resistant gasket. • 3/8-16 threaded collar studs provided for mounting optional panel. • Holes in body and door for mounting operating handle, operating mechanism, and door closing mechanism. • Cover interlock bracket welded to door. Finish: ANSI 61 gray polyester powder paint outside and inside. Optional panels are painted white polyester powder. • Furnished with door latch bar for door hardware. (disconnect switch, operating handle, operating mechanism, and door hardware are not furnished with the enclosure. They must be ordered separately from the disconnect manufacturer.) • Enclosures under 40" high require 2-point door hardware. • Enclosures 40" high and taller require 3-point door hardware. INDUSTRY STANDARDS UL 508 Type 12 CUL Type 12 NEMA Type 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 SINGLE DOOR ENCLOSURES FOR A-B FLANGE-MOUNTED DISCONNECTS OMIT TWO MIDDLE STUDS 3.00 B .44 DIA. IF "B" IS LESS THAN 32" 3.00 C X STIFFENER S S PANEL (ORDERED SEPARATELY) A Flange-Mounted Disconnect Enclosures .62 A-3.00 B-4 3/8 OMIT TWO MIDDLE STUDS IF "A" IS LESS THAN 31" X .44 .62 SECTION X-X DOOR STIFFENER MOUNTING FEET CONTINUOUS HINGE DOOR STIFFENER 2.75 1.38 3/8-16 COLLAR STUD SPACE OCCUPIED BY DISCONNECT NEOPRENE GASKET NOTE: D = 3.84 WHEN C = 8.00 D = 6.75 WHEN C = 10.00 D = 9.50 WHEN C = 12.00 (except enclosures for 200 amp switches) MOUNTING FEET BODY STIFFENER D = 9.50 WHEN C = 16.00 D = 10.50 WHEN C = 12.00 PANEL (ORDERED SEPARATELY) (for enclosures with 200 amp switches) SECTION S-S 1.50 W = WIRING SPACE W D CL TOP HOLE IS R.H. FLANGE E THIS SPACE IS OCCUPIED BY DISCONNECT SWITCH AND FUSE CLIP (IF USED) OR CIRCUIT BREAKER 1.30 F Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 2.62 Phone: 336.468.2851 800.288.2851 65 TYPE 12 SINGLE DOOR ENCLOSURES FOR A-B FLANGE-MOUNTED DISCONNECTS Flange-Mounted Disconnect Enclosures Type 12 Enclosures for Allen-Bradley Disconnects Catalog Number Enclosure Size AxBxC Panel Catalog Number Panel Size Ht.xWd . Print Pocket Stiffener Door/Body AB-20228N/ABDSC AB-24228N/ABDSC AB-24268N/ABDSC AB-30228N/ABDSC AB-30268N/ABDSC AB-36268N/ABDSC AB-36328N/ABDSC AB-42328N/ABDSC AB-42388N/ABDSC AB-48388N/ABDSC 20x21.38x8 24x21.38x8 24x25.38x8 30x21.38x8 30x25.38x8 36x25.38x8 36X31.38X8 42X31.38X8 42X37.38X8 48X37.38X8 AB-2020TP AB-2420TP AB-2424TP AB-3020TP AB-3024TP AB-3624TP AB-3630TP AB-4230TP AB-4236TP AB-4836TP 17x17 21x17 21x21 27x17 27x21 33x21 33x27 39x27 39x33 45x33 Small Small Small Small Large Large Large Small Large Large 0 0 0 0 0 0 0 1 1 1 0 0 0 0 0 0 1 1 1 1 AB-242210N/ABDSC AB-242610N/ABDSC AB-302210N/ABDSC AB-302610N/ABDSC AB-362610N/ABDSC AB-363210N/ABDSC AB-423210N/ABDSC AB-423810N/ABDSC AB-483810N/ABDSC AB-603810N/ABDSC 24x21.38x10 24x25.38x10 30x21.38x10 30x25.38x10 36x25.38x10 36x31.38x10 42x31.38x10 42x37.38x10 48x37.38x10 60x37.38x10 AB-2420TP AB-2424TP AB-3020TP AB-3024TP AB-3624TP AB-3630TP AB-4230TP AB-4236TP AB-4836TP AB-6036TP 21x17 21x21 27x17 27x21 33x21 33x27 39x27 39x33 45x33 57x33 Small Small Small Large Large Large Small Large Large Large 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 1 1 1 1 1 AB-363212N/ABDSC AB-423212N/ABDSC AB-423812N/ABDSC AB-483812N/ABDSC AB-603812N/ABDSC 36x31.38x12 42x31.38x12 42x37.38x12 48x37.38x12 60x37.38x12 AB-3630TP AB-4230TP AB-4236TP AB-4836TP AB-6036TP 33x27 39x27 39x33 45x33 57x33 Large Small Large Large Large 0 1 1 1 1 1 1 1 1 1 AB-483816N/ABDSC AB-603816N/ABDSC 48x37.38x16 60x37.38x16 AB-4836TP AB-6036TP 45x33 57x33 Large Large 1 1 1 1 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 SINGLE DOOR ENCLOSURES FOR A-B FLANGE-MOUNTED DISCONNECTS Flange-Mounted Disconnect Enclosures Disconnect Ordering Information: When using a Bulletin 1494F disconnect switch, order: – A disconnect switch (30A, 60A, or 100A) – A fuse block adapter, if required – Line and load connectors, if required – Door hardware (Bulletin 1494F-L1 for 2-point latching, or Bulletin 1494F-L2 and 1494F-L3 for 3-point latching) When using a Bulletin 1494D circuit breaker operating mechanism, order: – A circuit breaker (C-H/Westinghouse) – An operator mechanism – A slide mechanism – Door hardware (Bulletin 1494F-L1 for 2-point latching, or Bulletin 1494F-L2 and 1494F-L3 for 3-point latching) *Allen-Bradley 1494F Disconnect Switches Enclosure Depth 8.00 10.00 12.00 Wire Bend Space Above Disconnect 16.00 Type Number Amp Rating Fuse Clip Fuse Class Space Occupied E F (1) When D = 3.84 W When D = 6.75 W When D = 9.50 W 3.25 3.25 3.25 3.25 3.25 3.25 6.25 6.25 6.25 6.25 6.25 6.25 8.88 8.88 8.88 8.88 8.88 8.88 * * * * * * * * * * * * * * * * * * * * * * * * * * * * N30 NF30 NF30 NF30 NF30 NF30 NF30 30A 30A 30A 30A 30A 30A 30A NO FUSE 30A-250V 60A-250V 30A-600V 60A-600V 30A-600V 60A-600V NA H,K,R H,K,R H,K,R H,K,R J J 4.62 6.25 7.25 9.25 9.75 6.50 6.62 6.25 6.25 6.25 6.25 6.25 6.25 6.25 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * N60 NF60 NF60 NF60 NF60 NF60 NF60 NF60 60A 60A 60A 60A 60A 60A 60A 60A NO FUSE 30A-600V 60A-250V 100A-250V 60A-600V 100A-600V 60A-600V 100A-600V NA H,K,R H,K,R H,K,R H,K,R H,K,R J J 4.62 10.38 8.38 10.88 10.88 12.88 7.75 9.75 6.25 6.25 6.25 6.25 6.25 6.25 6.25 6.25 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 8.12 8.12 8.12 8.12 8.12 8.12 8.12 8.12 8.12 * * * * * * * * * * * * * * * * * * * * * N100 NF100 NF100 NF100 NF100 NF100 NF100 100A 100A 100A 100A 100A 100A 100A NO FUSE 100A-250V 200A-250V 100A-600V 200A-600V 100A-600V 200A-600V NA H,K,R H,K,R H,K,R H,K,R J J 4.62 11.38 12.25 13.38 14.75 10.12 10.88 7.00 7.00 7.25 7.12 7.38 7.00 7.25 NA NA NA NA NA NA NA 3.50 3.50 3.50 3.50 3.50 3.50 3.50 6.25 6.25 6.25 6.25 6.25 6.25 6.25 When D = 3.84 W When D = 6.75 W When D = 9.50 W 3.25 NA NA NA 6.12 5.34 5.31 5.44 8.88 8.09 8.06 8.19 *Allen-Bradley 1494D Circuit Breaker Operators Enclosure Depth 8.00 10.00 12.00 * * * * * * * * * 16.00 Type Number Frame Rating Breaker Type Frame Size (3 pole) * * * * N4/N40 N5/N55 N5/N50 N5/N60 150A 225A 250A 400A C-H/Westinghouse General Electric C-H/Westinghouse C-H/Westinghouse EHD, FD, FDB, FDC, HFD, HMCP TFC, TFK, THFK JD, JDB, JDC, HJD, HMCP KD, KDB, KDC, HKD, HMCP Space Occupied E F 5.81 8.81 8.81 8.81 4.31 4.50 4.50 5.62 (1) The "F" dimensions does not include space for auxiliary switches. See Allen-Bradley instructions for additional space required. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 67 TYPE 12 DOUBLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Construction: • 10 gauge steel. Flange-Mounted Disconnect Enclosures • Seams continuously welded and ground smooth. • Body stiffeners in larger enclosures for extra rigidity. • Removable centerpost for easy installation of optional panel. • Heavy gauge continuous hinge. • 3-point latching mechanisms operated by padlocking handle on all doors. • Heavy duty lifting eyes. • Print pocket included. • 15" floor stands are welded to enclosure. • Oil-resistant gasket. • Panel supports for optional panel. • 3/8-16 threaded collar studs provided for mounting optional panel. • Defeater on master door requires a screwdriver to open. • Mechanical interlock operated by master door prevents slave door from being opened first. Finish: ANSI 61 gray polyester powder paint outside and inside. Optional panels are painted white polyester powder. INDUSTRY STANDARDS UL 508 Type 12 NEMA Type 12 CUL Type 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 DOUBLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS 1.25 B C X Flange-Mounted Disconnect Enclosures 1.38 PADLOCKABLE HANDLE A 2.25 1.38 4.00 A/2 + 15.00 3.00 1.38 15.00 CONTINUOUS HINGE REMOVABLE CENTERPOST X 2.06 D W TOP OF DISCONNECT E THIS SPACE IS OCCUPIED BY DISCONNECT SWITCH AND FUSE CLIP (IF USED) OR CIRCUIT BREAKER F 2.44 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 69 TYPE 12 DOUBLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Austin Type 12 double door enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: Flange-Mounted Disconnect Enclosures • ABB Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. • Allen-Bradley Bulletin 1494F flange-mounted disconnect switches and Bulletin 1494D flange-mounted operators for circuit breakers. Allen-Bradley Bulletin 1494V variable depth flange-operated disconnect switches and circuit breaker mechanisms. • Cutler-Hammer/Westinghouse Type C361 disconnect switches and operator mechanisms, and Type C371 circuit breakers and circuit breaker operating mechanisms. Also Type SM safety handle mechanisms and Flex Shaft handle operators for circuit breakers. • General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also Spectra Flex cable operators for circuit breakers. • I-T-E Max-Flex flange-mounted variable depth operating handles for disconnect switches and circuit breakers. • Square D disconnect switches and circuit breakers used with Class 9422 flange-mounted variable depth operating mechanisms or cable mechanisms. (These enclosures will not receive Class 9422 bracket-mounted disconnect devices, Class 9422TG1, or TG2 devices.) Catalog Number Enclosure Size AxBxC Panel Catalog Number Panel Size Ht. X Wd. AB-604812ND/FDSC AB-606012ND/FDSC AB-726012ND/FDSC AB-727212ND/FDSC 60x49.62x12 60x61.62x12 72x61.62x12 72x73.62x12 AB-6048DP AB-6060DP AB-7260DP AB-7272DP 56x44 56x56 68x56 68x68 AB-604818ND/FDSC AB-606018ND/FDSC AB-726018ND/FDSC AB-727218ND/FDSC 60x49.62x18 60x61.62x18 72x61.62x18 72x73.62x18 AB-6048DP AB-6060DP AB-7260DP AB-7272DP 56x44 56x56 68x56 68x68 AB-604824ND/FDSC AB-606024ND/FDSC AB-727224ND/FDSC 60x49.62x24 60x61.62x24 72x73.62x24 AB-6048DP AB-6060DP AB-7272DP 56x44 56x56 68x68 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 D I S C O N N E C T O R D E R I N G I N F O R M AT I O N Allen-Bradley When using a Bulletin 1494F flange-mounted disconnect switch, order: – A disconnect switch – A fuse block adapter (if required) – Line and load connector (if required) When using a Bulletin 1494D flange-mounted operator for a circuit breaker, order: – A circuit breaker (C-H/Westinghouse) – A flange-mounted operator mechanism – A slide mechanism When using a Bulletin 1494V disconnect switch, order: – A disconnect switch – An operating handle – A connecting rod (long) – A trailer fuse block kit (if required) – A fuse clip kit (if required) – Line and load connectors (if required) When using a Bulletin 1494V circuit breaker operating mechanism, order: – A circuit breaker (C-H/Westinghouse) – A circuit breaker operating mechanism – An operating handle – A connecting rod (long) ABB Controls When using a disconnect switch, order: – A flange-operated switch (fusible or non-fusible) – A shaft [DSFHS-12 for 12" deep or DSFHS-17 for 18" deep enclosures; in 24" deep enclosures platform must be used with shaft] – A handle (DSFHN-HS12) When using a circuit breaker, order: – A circuit breaker (ABB) – An operating mechanism – A shaft [FSH-12 for 12" deep or FHS-17 for 18" deep enclosures; in 24" deep enclosures platform must be used with shaft] – A handle mechanism (FHN-HS12) Cutler-Hammer/Westinghouse When using a File C361 disconnect switch, order: – A disconnect switch with an operating mechanism – An operating handle (C361H1 or C361H3) When using a File C371 circuit breaker operating mechanism with C-H/Westinghouse circuit breaker, order: – A circuit breaker – An operating mechanism – An operating handle When using a Type SM handle mechanism, order: – A circuit breaker – A Type SM handle mechanism When using a Flex Shaft handle mechanism, order: – A circuit breaker – A complete Flex Shaft handle mechanism General Electric When ordering a disconnect switch, order: – A disconnect switch (Type QMR or QMW) – A fuse clip or no-fuse kit – A flange handle (STDA1 or STDA2) – A variable depth operating mechanism – An extended length drive rod (if required) When using a circuit breaker, order: – A circuit breaker – A flange handle (STDA1 or STDA2) – A variable depth operating mechanism – An extended length drive rod (if required) Flange-Mounted Disconnect Enclosures When ordering floor-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. When using a circuit breaker with a Spectra Flex cable operator, order: – A circuit breaker – A flange-mounted handle mechanism – A breaker-mounted mechanism – An operating cable I-T-E Siemens When using a disconnect switch, order: – A basic switch (right-hand) – A fuse or no-fuse kit – FHOHS flange-mounted handle – Switch operator – FHOECO36 cable for 12" deep or FHOECO48 for 18" and 24" deep enclosures When using a circuit breaker, order: – A circuit breaker – Pressure wire connectors – A flange-mounted handle – An operating cable [12" deep or 18" deep enclosures accept 36" or 48" cables; 24" deep enclosures require a 48" cable] Square D When using a disconnect switch, order: – A disconnect switch with operating mechanism – A universal handle mechanism – A long operating rod (if required) When using a circuit breaker, order: – A circuit breaker – An operating mechanism – A universal handle mechanism – A long operating rod (if required) When using a Class 9422 Type “T” disconnect switch with a cable mechanism, order: – A disconnect switch with operating mechanism (Class 9422, Type T) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT-O) 3-, 5-, or 10-foot When using a circuit breaker with a cable mechanism, order: – A circuit breaker (Square D) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT-0) 3-, 5-, or 10-foot Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 71 TYPE 12 S I N G L E D O O R F R E E S TA N D I N G ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Flange-Mounted Disconnect Enclosures Construction: • 10 gauge steel. • Seams continuously welded and ground smooth. • Body stiffeners in larger enclosures for extra rigidity. • Heavy duty lifting eyes. • Heavy gauge continuous hinges. • 3-point latching mechanisms operated by padlocking handle doors. • Print pocket included. • Oil-resistant gasket. • Panel supports for panel. • 3/8-16 threaded collar studs provided for mounting panel. • Defeater on door requires a screwdriver to open. Finish: ANSI 61 gray polyester powder outside and inside. Optional panels are painted white polyester powder. INDUSTRY STANDARDS UL 508 Type 12 NEMA Type 12 CUL Type 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 1.25 Flange-Mounted Disconnect Enclosures S I N G L E D O O R F R E E S TA N D I N G E N C L O S U R E F O R FLANGE-MOUNTED DISCONNECT C X B 3.00 4.00 2.38 3.25 PADLOCKABLE HANDLE A 1.38 2.25 PANEL SUPPORT A/2 + 2.00 3.00 .88 .88 CONTINUOUS HINGE 8.00 7.00 X SECTION X-X PANEL 4.06 W D TOP OF DISCONNECT E THIS SPACE IS OCCUPIED BY DISCONNECT SWITCH AND FUSE CLIP (IF USED) OR CIRCUIT BREAKER F 2.44 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 73 TYPE 12 S I N G L E D O O R F R E E S TA N D I N G ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Flange-Mounted Disconnect Enclosures Austin Type 12 single door freestanding enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: • ABB Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. • Allen-Bradley flange-mounted disconnect switches and Bulletin 1494D flange-mounted operators for circuit breakers. Allen-Bradley Bulletin 1494V variable depth flange-operated disconnect switches and circuit breaker mechanisms. • Cutler-Hammer/Westinghouse Type C361 disconnect switches and operator mechanisms. Cutler-Hammer Type C371 circuit breaker operating mechanisms. Also Type SM safety handle mechanisms and Flex Shaft handle operators for circuit breakers. • General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also Spectra Flex cable operators for circuit breakers. • I-T-E Max-Flex flange-mounted variable depth operating handles for disconnect switches and circuit breakers. • Square D disconnect switches and circuit breakers used with Class 9422 flange-mounted variabledepth operating mechanisms or cable mechanisms. (These enclosures will not receive Class 9422 bracket-mounted disconnect devices, Class 9422TG1 or TG2 devices.) Catalog Number Enclosure Size AxBxC Panel Catalog Number Panel Size Ht. X Wd. AB-722718FSN/DSC AB-723318FSN/DSC AB-723918FSN/DSC AB-843918FSN/DSC AB-903918FSN/DSC 72x27.38x18 72x33.38x18 72x39.38x18 84x39.38x18 90x39.38x20 AB-7227DSCP AB-7233DSCP AB-7239DSCP AB-8439DSCP AB-9039DSCP 60x21.75 60x27.75 60x33.75 72x33.75 78x33.75 AB-903920FSN/DSC 90x39.38x20 AB-9039DSCP 78x33.75 AB-843924FSN/DSC AB-903924FSN/DSC 84x39.38x24 90x39.38x24 AB-8439DSCP AB-9039DSCP 72x33.75 78x33.75 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 S I N G L E D O O R F R E E S TA N D I N G E N C L O S U R E S FOR FLANGE-MOUNTED DISCONNECTS Allen-Bradley When using a Bulletin 1494F flange-mounted disconnect switch, order: – A disconnect switch – A fuse block adapter (if required) – Line and load connector (if required) When using a Bulletin 1494D flange-mounted operator for a circuit breaker, order: – A circuit breaker (C-H/Westinghouse) – A flange-mounted operator mechanism – A slide mechanism When using a Bulletin 1494V disconnect switch, order: – A disconnect switch – An operating handle – A connecting rod (long) – A trailer fuse block kit (if required) – A fuse clip kit (if required) – Line and load connectors (if required) When using a Bulletin 1494V circuit breaker operating mechanism, order: – A circuit breaker (C-H/Westinghouse) – A circuit breaker operating mechanism – An operating handle – A connecting rod (long) ABB Controls When using a disconnect switch, order: – A flange-operated switch (fusible or non-fusible) – A shaft [DSFHS-12 for 12" deep or DSFHS-17 for 18" deep enclosures; in 24" deep enclosures platform must be used with shaft] – A handle (DSFHN-HS12) When using a circuit breaker, order: – A circuit breaker (ABB) – An operating mechanism – A shaft [FSH-12 for 12" deep or FHS-17 for 18" deep enclosures; in 24" deep enclosures platform must be used with shaft] – A handle mechanism (FHN-HS12) Cutler-Hammer/Westinghouse When using a File C361 disconnect switch, order: – A disconnect switch with an operating mechanism – An operating handle (C361H1 or C361H3) When using a File C371 circuit breaker operating mechanism with C-H/Westinghouse circuit breaker, order: – A circuit breaker – An operating mechanism - An operating handle When using a Type SM handle mechanism, order: – A circuit breaker – A Type SM handle mechanism When using a Flex Shaft handle mechanism, order: – A circuit breaker – A complete Flex Shaft handle mechanism General Electric When ordering a disconnect switch, order: – A disconnect switch (Type QMR or QMW) – A fuse clip or no-fuse kit – A flange handle (STDA1 or STDA2) – A variable depth operating mechanism – An extended length drive rod (if required) When using a circuit breaker, order: – A circuit breaker – A flange handle (STDA1 or STDA2) – A variable depth operating mechanism – An extended length drive rod (if required) Flange-Mounted Disconnect Enclosures When ordering floor-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. When using a circuit breaker with a Spectra Flex cable operator, order: – A circuit breaker – A flange-mounted handle mechanism – A breaker-mounted mechanism – An operating cable I-T-E Siemens When using a disconnect switch, order: – A basic switch (right-hand) – A fuse or no-fuse kit – FHOHS flange-mounted handle – Switch operator – FHOECO36 cable for 12" deep or FHOECO48 for 18" and 24" deep enclosures When using a circuit breaker, order: A circuit breaker Pressure wire connectors A flange-mounted handle An operating cable [12" deep or 18" deep enclosures accept 36" or 48" cables; 24" deep enclosures require a 48" cable] – – – – Square D When using a disconnect switch, order: – A disconnect switch with operating mechanism – A universal handle mechanism – A long operating rod (if required) When using a circuit breaker, order: - A circuit breaker – An operating mechanism – A universal handle mechanism – A long operating rod (if required) When using a Class 9422 Type “T” disconnect switch with a cable mechanism, order: – A disconnect switch with operating mechanism (Class 9422, Type T) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT-O) 3-, 5-, or 10-foot When using a circuit breaker with a cable mechanism, order: – A circuit breaker (Square D) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT-0) 3-, 5-, or 10-foot Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 75 TYPE 12 F R E E S TA N D I N G D O U B L E D O O R ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Flange-Mounted Disconnect Enclosures Construction: • 10 gauge steel. • Seams continuously welded and ground smooth. • Body stiffeners in larger enclosures for extra rigidity. • Heavy duty lifting eyes. • Removable centerpost for easy installation of panel. • Heavy gauge continuous hinges. • 3-point latching mechanisms operated by padlocking handle on all doors. • Print pocket included. • Oil-resistant gasket. • Panel supports for panel. • 3/8-16 threaded collar studs provided for mounting panel. • Defeater on master door requires a screwdriver to open. • Mechanical interlock operated by master door prevents slave door from being opened first. Finish: ANSI 61 gray polyester powder outside and inside. Optional panels are painted white polyester powder. INDUSTRY STANDARDS UL 508 Type 12 NEMA Type 12 CUL Type 12 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 1.25 Flange-Mounted Disconnect Enclosures F R E E S TA N D I N G D O U B L E D O O R E N C L O S U R E FOR FLANGE-MOUNTED DISCONNECT C X B 4.00 3.00 .88 .88 B-5.62 PADLOCKABLE HANDLE 3.25 2.38 A-4.00 A 1.38 2.25 3.00 CONTINUOUS HINGE BODY STIFFENER A/2 + 2.00 7.00 PANEL SUPPORT 8.00 X SECTION X-X PANEL 4.06 W D TOP OF DISCONNECT E THIS SPACE IS OCCUPIED BY DISCONNECT SWITCH AND FUSE CLIP (IF USED) OR CIRCUIT BREAKER F 2.44 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 77 TYPE 12 F R E E S TA N D I N G D O U B L E D O O R ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Austin Type 12 double door freestanding enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: Flange-Mounted Disconnect Enclosures • ABB Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. • Allen-Bradley Bulletin 1494F flange-mounted disconnect switches and Bulletin 1494D flangemounted operators for circuit breakers. Allen-Bradley Bulletin 1494V variable depth flange-operated disconnect switches and circuit breaker mechanisms. • Cutler-Hammer/Westinghouse Type C361 disconnect switches and operator mechanisms. Cutler-Hammer Type C371 circuit breaker operating mechanisms. Also Type SM safety handle mechanisms and Flex Shaft handle operators for circuit breakers. • General Electric Type STDA flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. Also Spectra Flex cable operators for circuit breakers. • I-T-E Max-Flex flange-mounted variable depth operating handles for disconnect switches and circuit breakers. • Square D disconnect switches and circuit breakers used with Class 9422 flange-mounted variabledepth operating mechanisms or cable mechanisms. (These enclosures will not receive Class 9422 bracket-mounted disconnect devices, Class 9422TG1 or TG2 devices.) Catalog Number Enclosure Size AxBxC Panel Catalog Number Panel Size Ht. X Wd. AB-725318FSND/DSC AB-726518FSND/DSC AB-727718FSND/DSC AB-847718FSND/DSC AB-907718FSND/DSC 72x53.62x18 72x65.62x18 72x77.62x18 84x77.62x18 90x77.62x18 AB-7253DSCP AB-7265DSCP AB-7277DSCP AB-8477DSCP AB-9077DSCP 60x46 60x58 60x70 72x70 78x70 AB-907720FSND/DSC 90x77.62x20 AB-9077DSCP 78x70 AB-727724FSND/DSC AB-847724FSND/DSC AB-907724FSND/DSC 72x77.62x24 84x77.62x24 90x77.62x24 AB-7277DSCP AB-8477DSCP AB-9077DSCP 60x70 72x70 78x70 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 F R E E S TA N D I N G D O U B L E D O O R E N C L O S U R E FOR FLANGE-MOUNTED DISCONNECT Allen-Bradley When using a Bulletin 1494F flange-mounted disconnect switch, order: – A disconnect switch – A fuse block adapter (if required) – Line and load connector (if required) When using a Bulletin 1494D flange-mounted operator for a circuit breaker, order: – A circuit breaker (C-H/Westinghouse) – A flange-mounted operator mechanism – A slide mechanism When using a Bulletin 1494V disconnect switch, order: – A disconnect switch – An operating handle – A connecting rod (long) – A trailer fuse block kit (if required) – A fuse clip kit (if required) – Line and load connectors (if required) When using a Bulletin 1494V circuit breaker operating mechanism, order: – A circuit breaker (C-H/Westinghouse) – A circuit breaker operating mechanism – An operating handle – A connecting rod (long) ABB Controls When using a disconnect switch, order: – A flange-operated switch (fusible or non-fusible) – A shaft [DSFHS-12 for 12" deep or DSFHS-17 for 18" deep enclosures; in 24" deep enclosures platform must be used with shaft] – A handle (DSFHN-HS12) When using a circuit breaker, order: – A circuit breaker (ABB) – An operating mechanism – A shaft [FSH-12 for 12" deep or FHS-17 for 18" deep enclosures; in 24" deep enclosures platform must be used with shaft] – A handle mechanism (FHN-HS12) Cutler-Hammer/Westinghouse When using a File C361 disconnect switch, order: – A disconnect switch with an operating mechanism – An operating handle (C361H1 or C361H3) When using a File C371 circuit breaker operating mechanism with C-H/Westinghouse circuit breaker, order: – A circuit breaker – An operating mechanism - An operating handle When using a Type SM handle mechanism, order: – A circuit breaker – A Type SM handle mechanism When using a Flex Shaft handle mechanism, order: – A circuit breaker – A complete Flex Shaft handle mechanism General Electric When ordering a disconnect switch, order: – A disconnect switch (Type QMR or QMW) – A fuse clip or no-fuse kit – A flange handle (STDA1 or STDA2) – A variable depth operating mechanism – An extended length drive rod (if required) When using a circuit breaker, order: – A circuit breaker – A flange handle (STDA1 or STDA2) – A variable depth operating mechanism – An extended length drive rod (if required) Flange-Mounted Disconnect Enclosures When ordering floor-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. When using a circuit breaker with a Spectra Flex cable operator, order: – A circuit breaker – A flange-mounted handle mechanism – A breaker-mounted mechanism – An operating cable I-T-E Siemens When using a disconnect switch, order: – A basic switch (right-hand) – A fuse or no-fuse kit – FHOHS flange-mounted handle – Switch operator – FHOECO36 cable for 12" deep or FHOECO48 for 18" and 24" deep enclosures When using a circuit breaker, order: A circuit breaker Pressure wire connectors A flange-mounted handle An operating cable [12" deep or 18" deep enclosures accept 36" or 48" cables; 24" deep enclosures require a 48" cable] – – – – Square D When using a disconnect switch, order: – A disconnect switch with operating mechanism – A universal handle mechanism – A long operating rod (if required) When using a circuit breaker, order: - A circuit breaker – An operating mechanism – A universal handle mechanism – A long operating rod (if required) When using a Class 9422 Type “T” disconnect switch with a cable mechanism, order: – A disconnect switch with operating mechanism (Class 9422, Type T) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT-O) 3-, 5-, or 10-foot When using a circuit breaker with a cable mechanism, order: – A circuit breaker (Square D) – A handle mechanism (Class 9422 Type A-1) – A cable mechanism (Class 9422 CFT-0) 3-, 5-, or 10-foot Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 79 TYPE 12 F L O O R M O U N T & F R E E S TA N D I N G ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Flange-Mounted Disconnect Enclosures Allen-Bradley 1494F Disconnect Switches Wire Bend Space Above Disconnect Allen-Bradley 1494F Disconnect Switches Space Occupied E F* Floor Mount Enclosures Type 12 When When A = 60 A = 72 W W Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W Type Number Amp Rating Fuse Clip Fuse Class N30 NF30 NF30 NF30 NF30 NF30 NF30 30A 30A 30A 30A 30A 30A 30A NO FUSE 30A-250V 60A-250V 30A-600V 60A-600V 30A-600V 60A-600V NA H,K,R H,K,R H,K,R H,K,R J J 4.62 6.25 7.25 9.25 9.75 6.50 6.62 6.50 6.50 6.50 6.50 6.50 6.50 6.50 5.31 5.31 5.31 5.31 5.31 5.31 5.31 10.81 10.81 10.81 10.81 10.81 10.81 10.81 9.31 9.31 9.31 9.31 9.31 9.31 9.31 14.81 14.81 14.81 14.81 14.81 14.81 14.81 17.81 17.81 17.81 17.81 17.81 17.81 17.81 N60 NF60 NF60 NF60 NF60 NF60 NF60 NF60 60A 60A 60A 60A 60A 60A 60A 60A NO FUSE 30A-600V 60A-250V 100A-250V 60A-600V 100A-600V 60A-600V 100A-600V NA H,K,R H,K,R H,K,R H,K,R H,K,R J J 4.62 10.38 8.38 10.88 10.88 12.88 7.75 9.75 6.50 6.50 6.50 6.50 6.50 6.50 6.50 6.50 4.62 4.62 4.62 4.62 4.62 4.62 4.62 4.62 10.12 10.12 10.12 10.12 10.12 10.12 10.12 10.12 8.62 8.62 8.62 8.62 8.62 8.62 8.62 8.62 14.12 14.12 14.12 14.12 14.12 14.12 14.12 14.12 17.12 17.12 17.12 17.12 17.12 17.12 17.12 17.12 N100 NF100 NF100 NF100 NF100 NF100 NF100 100A 100A 100A 100A 100A 100A 100A NO FUSE 100A-250V 200A-250V 100A-600V 200A-600V 100A-600V 200A-600V NA H,K,R H,K,R H,K,R H,K,R J J 4.62 11.38 12.25 13.38 14.75 10.12 10.88 7.25 7.38 7.62 7.50 7.75 7.38 7.50 NA NA NA NA NA NA NA 8.25 8.25 8.25 8.25 8.25 8.25 8.25 6.75 6.75 6.75 6.75 6.75 6.75 6.75 12.25 12.25 12.25 12.25 12.25 12.25 12.25 15.25 15.25 15.25 15.25 15.25 15.25 15.25 N200 NF200 NF200 NF200 NF200 NF200 NF200 200A 200A 200A 200A 200A 200A 200A NO FUSE 200A-250V 400A-250V 200A-600V 400A-600V 200A-600V 400A-600V NA H,K,R H,K,R H,K,R H,K,R J J 7.12 15.00 16.56 17.56 19.56 13.69 15.00 10.38 10.38 10.75 10.38 11.00 10.38 10.62 NA NA NA NA NA NA NA 6.62 6.62 6.62 6.62 6.62 6.62 6.62 5.12 5.12 5.12 5.12 5.12 5.12 5.12 10.62 10.62 10.62 10.62 10.62 10.62 10.62 13.62 13.62 13.62 13.62 13.62 13.62 13.62 *The "F" dimensions do not include space for auxiliary switches. See Allen-Bradley instructions for additional space required. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 D I S C O N N E C T W I R I N G S PA C E I N F O R M AT I O N Wire Bend Space Above Disconnect Type Number Frame Rating N4/N40 150A N5/N55 225A N5/N50 250A N5/N60 400A Circuit Breaker Type Frame Size Space Occupied E F* Westinghouse EHD, FD, FDB, FDC, HFD, HMCP General Electric TFC, TFK, THFK Westinghouse JD, JDB, JDC, HJD, HMCP Westinghouse KD, KDB, KDC, HKD, HMCP Floor Mount Enclosures Type 12 When When A = 60 A = 72 W W Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W 5.81 4.31 5.25 10.75 9.25 14.75 17.75 8.81 4.50 4.44 9.94 8.44 13.94 16.94 8.81 4.50 4.44 9.84 8.44 13.94 16.94 8.81 5.62 NA 10.00 8.50 14.00 17.00 *The "F" dimensions do not include space for auxiliary switches. See Allen-Bradley for additonal space required. For Floor Mount Disconnects: "D" = 5.88 when "A" = 60 "D" = 11.38 when "A" = 72 (except for 200A switches) "D" = 10.06 when "A" = 72 (for 200A switches) For Freestanding Disconnects: "D" = 9.88 when "A" = 72 (except for 200A switches) "D" = 8.56 when "A" = 72 (for 200 A switches) "D" = 15.38 when "A" = 84 (except for 200A switches) "D" = 14.06 when "A" = 84 (for 200A switches) "D" = 18.38 when "A" = 90 (except for 200A switches) "D" = 17.06 when "A" = 90 (for 200A switches) Allen-Bradley 1494V Disconnect Switches Flange-Mounted Disconnect Enclosures Allen-Bradley Bulletin 1494D Operators for Circuit Breakers Wire Bend Space Above Disconnect Allen-Bradley 1494V Disconnect Switches Space Occupied E F* Floor Mount Enclosures Type 12 When When A = 60 A = 72 W W Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W Type Number Amp Rating Fuse Clip Fuse Class DS30 DS30 DS30 DS30 DS30 DS30 DS30 30A 30A 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 30A-600V 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R J H,K H,K J 3.88 5.25 8.00 5.25 6.00 8.50 5.38 6.75 6.75 6.75 6.75 6.75 6.75 6.75 6.00 6.00 6.00 6.00 6.00 6.00 6.00 11.50 11.50 11.50 11.50 11.50 11.50 11.50 10.00 10.00 10.00 10.00 10.00 10.00 10.00 15.50 15.50 15.50 15.50 15.50 15.50 15.50 18.50 18.50 18.50 18.50 18.50 18.50 18.50 DS60 DS60 DS60 DS60 DS60 DS60 DS60 DS60 60A 60A 60A 60A 60A 60A 60A 60A NO FUSE 60A-250V 60A-600V 60A-600V 30A-600V 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J H,K,R H,K H,K J 3.88 6.00 8.50 5.38 8.00 8.50 10.50 7.25 6.75 6.75 6.75 6.75 6.75 6.75 6.75 6.75 5.81 5.81 5.81 5.81 5.81 5.81 5.81 5.81 11.31 11.31 11.31 11.31 11.31 11.31 11.31 11.31 9.81 9.81 9.81 9.81 9.81 9.81 9.81 9.81 15.31 15.31 15.31 15.31 15.31 15.31 15.31 15.31 18.31 18.31 18.31 18.31 18.31 18.31 18.31 18.31 DS100** DS100** DS100** DS100** DS100** DS100** 100A 100A 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V 60A-600V 60A-600V NA H,K,R H,K,R J H,K,R J 3.88 8.12 10.12 6.80 10.12 8.88 6.75 6.75 6.75 6.75 6.75 6.75 5.81 5.81 5.81 5.81 5.81 5.81 11.31 11.31 11.31 11.31 11.31 11.31 9.81 9.81 9.81 9.81 9.81 9.81 15.31 15.31 15.31 15.31 15.31 15.31 18.31 18.31 18.31 18.31 18.31 18.31 DS200** DS200** DS200** DS200** DS200** DS200** 200A 200A 200A 200A 200A 200A NO FUSE 200A-250V 200A-600V 200A-600V 100A-600V 100A-600V NA H,K,R H,K,R J H,K,R J 4.75 10.88 13.88 9.50 12.00 8.75 8.00 8.00 8.00 8.00 8.00 8.00 4.34 4.34 4.34 4.34 4.34 4.34 9.84 9.84 9.84 9.84 9.84 9.84 8.34 8.34 8.34 8.34 8.34 8.34 13.84 13.84 13.84 13.84 13.84 13.84 16.84 16.84 16.84 16.84 16.84 16.84 *The "F" dimensions do not include space for auxiliary switches. See Allen-Bradley instructions for additional space required. **Series B Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 81 TYPE 12 F L O O R M O U N T & F R E E S TA N D I N G ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Flange-Mounted Disconnect Enclosures Wire Bend Space Above Disconnect Allen-Bradley Bulletin 1494V Operators for Circuit Breakers Type Number Frame Rating Circuit Breaker Type Frame Size M40 15A-150A M50 70A-250A M60 100A-400A Floor Mount Enclosures Type 12 When When A = 60 A = 72 W W Space Occupied E F* Westinghouse EHD, FD, FDB, FDC, HFD, HMCP Westinghouse JD, JDB, JDC, HJD, HMCP Westinghouse KD, KDB, KDC. HKD, HMCP Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W 5.00 4.62 7.25 12.75 11.25 16.75 19.75 9.75 4.88 6.81 12.31 10.81 16.31 19.31 9.69 6.25 NA 12.12 10.62 16.12 19.12 *The "F" dimensions do not include space for auxiliary switches. See Allen-Bradley instructions for additional space required. For Floor Mount Disconnects: For Floor Mount Disconnects: For Freestanding Disconnects: For Freestanding Disconnects: "D" = 11.88 when "A" = 72 "D" = 17.38 when "A" = 84 "D" = 20.38 when "A" = 90 "D" = 7.88 when "A" = 60 "D" = 13.38 when "A" = 72 Wire Bend Space Above Disconnect ABB Controls Disconnect Switches with Flange-Mounted Operators Switch Number Space Occupied E F Double Door Enclosures Type 12 When When A = 60 A = 72 W W Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W Amp Rating Fuse Clip Fuse Class OETL-NF30-F OETL-NF60-F OETL-NF100-F OETL-NF175-F OETL-NF200-F 40A 80A 100A 175A 200A NO FUSE NO FUSE NO FUSE NO FUSE NO FUSE NA NA NA NA NA 4.45 4.86 4.86 7.30 7.36 3.91 3.91 4.91 6.62 7.41 9.53 9.34 8.78 6.53 6.53 15.03 14.84 17.28 12.03 12.03 13.53 13.34 15.78 10.53 10.53 19.03 18.84 21.28 16.03 16.06 22.03 21.84 24.28 19.03 19.03 OESA-F30J6-F OESA-F60J6-F OESA-F100J6-F 30A 60A 100A 30A-600V 60A-600V 100A-600V J J J 4.28 4.28 6.54 6.70 6.39 7.78 7.85 7.85 7.42 13.36 13.36 12.92 11.86 11.86 11.42 17.36 17.36 16.92 20.36 20.36 19.92 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 D I S C O N N E C T W I R I N G S PA C E I N F O R M AT I O N ABB Controls Circuit Breakers with Flange-Mounted Operators Mechanism FHD-M FHF-M FHF-M FHJ-M FHM-M FHM-M FHN-M Amp Rating Frame Type 150A 150A-225A 225A 400A 600A 800A 1200A D E/Q F J L M N Space Occupied E F 6.92 5.98 7.44 9.71 8.28 10.11 12.18 Floor Mount Disconnects: For Floor MountFor Disconnects: Floor Mount Enclosures Type 12 When When A = 60 A = 72 W W 4.06 4.55 4.55 5.75 11.39 11.39 11.39 8.42 6.97 6.97 5.02 NA NA NA 13.92 12.47 12.47 10.52 10.03 9.62 NA Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W 12.42 10.97 10.97 9.02 8.53 8.12 NA 17.92 16.47 16.47 14.52 14.03 13.62 9.81 20.92 19.47 19.47 17.52 17.03 16.62 12.81 Flange-Mounted Disconnect Enclosures Wire Bend Space Above Disconnect "D" = 7.88 when "A" = 60 "D" = 13.38 when "A" = 72 For Freestanding Disconnects: For Freestanding Disconnects: "D" = 11.88 when "A" = 72 "D" = 17.38 when "A" = 84 "D" = 20.38 when "A" = 90 Wire Bend Space Above Disconnect Cutler-Hammer C361 Disconnect Switches Switch Number Space Occupied E F Double Door Enclosures Type 12 When When A = 60 A = 72 W W Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W Amp Rating Fuse Clip Fuse Class C361NC C361SC21 C361SC61 C361SC61 30A 30A 30A 30A NO FUSE 30A-250V 60A-250V 30A-600V NA H,K,R H,K,R H,J,K,R 5.75 8.38 8.38 8.38 7.55 7.55 7.55 7.55 6.50 6.50 6.50 6.50 12.00 12.00 12.00 12.00 10.50 10.50 10.50 10.50 16.00 16.00 16.00 16.00 19.00 19.00 19.00 19.00 C361ND C361SD22 C361SD22 C361SD62 C361SD62 60A 60A 60A 60A 60A NO FUSE 60A-250V 30A-600V 60A-600V 60A-600V NA H,K,R J H,K,R J 5.75 8.38 8.38 8.38 8.38 7.55 7.55 7.55 7.55 7.55 6.50 6.50 6.50 6.50 6.50 12.00 12.00 12.00 12.00 12.00 10.50 10.50 10.50 10.50 10.50 16.00 16.00 16.00 16.00 16.00 19.00 19.00 19.00 19.00 19.00 C361NE C361SE263 C361SE263 C361SE263 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J 5.56 10.31 10.31 10.31 9.07 9.07 9.07 9.07 6.06 6.06 6.06 6.06 11.56 11.56 11.56 11.56 10.06 10.06 10.06 10.06 15.56 15.56 15.56 15.56 18.56 18.56 18.56 18.56 C361NF C361SF264 C361SF264 200A 200A 200A NO FUSE 200A-250V 200A-600V NA H,K,R H,J,K,R 13.06 13.06 13.06 10.12 10.12 10.12 4.06 4.06 4.06 9.62 9.62 9.62 8.06 8.06 8.06 13.62 13.62 13.62 16.62 16.62 16.62 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 83 TYPE 12 F L O O R M O U N T & F R E E S TA N D I N G ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Wire Bend Space Above Disconnect Cutler-Hammer C371 Circuit Breaker Operators for C-H / Westinghouse Circuit Breakers Mechanism Flange-Mounted Disconnect Enclosures Space Occupied E F Floor Mount Enclosures Type 12 When When A = 60 A = 72 W W Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W Max Amp Rating Frame Type C371E C371E 225A 150A F Frame: EHD, FDB, FD, HFD, FDC F Frame: HMCP 6.00 6.00 5.62 5.62 7.62 7.62 13.12 13.12 11.62 11.62 17.12 17.12 20.12 20.12 C371F C371F 250A 250A J Frame: JDB, JD, HJD, JDC J Frame: HCMP 8.94 10.94 8.12 8.12 7.50* 7.50* 13.00 13.00 11.44 11.44 16.94 16.94 20.00 20.00 C371F C371F 400A 400A K Frame: DK, KDB, KD, HKD K Frame: HMCP 9.75 9.75 8.12 8.12 7.00* 7.00* 12.50 12.50 11.00 11.00 16.50 16.50 19.50 19.50 C371G C371G 600A 600A L Frame: LD, HLD, LDC L Frame: HMCP 8.44 8.44 12.00 12.00 NA NA 10.88** 10.88** 9.38 9.38 14.88 14.88 17.88 17.88 C371K 800A M Frame: MD, MDS 10.25 12.00 NA NA NA 11.31 14.31 C371K 1200A N Frame: ND, HND, NDC 10.25 12.00 NA NA NA 11.31*** 14.31 *Available wire bend space "W" does not allow cable sizes larger than 4/0 AWG in a 60" tall enclosure. **Available wire bend space "W" does not allow cable sizes larger than 300 MCM. ***Available wire bend space "W" does not allow cable sizes larger than 350 MCM in a 90" tall enclosure when using 4 cable per terminal. See National Electrical Code 1999 table 373-6(b) for more information. Available wire bend space "W" is insufficient for use with Westinghouse breakers equipped with TA1201NB1 terminals. For Floor Mount Disconnects: For Floor Mount Disconnects: "D" = 7.88 when "A" = 60 "D" = 13.38 when "A" = 72 For Freestanding Disconnects: For Freestanding Disconnects: "D" = 11.88 when "A" = 72 "D" = 17.38 when "A" = 84 "D" = 20.38 when "A" = 90 Cutler-Hammer Flex Shaft Operator Mechanisms for C-H/Westinghouse Circuit Breakers Complete Operator Mechanism Amp Rating Frame Type Breaker Height Breaker Width F1S03 F1S03 225A 150A F-Frame/EHD, FDB, FD, HFD, FDC F-Frame HMCP 6.00 6.00 4.12 4.12 F2S03 F2S03 250A 250A J-Frame/JDB, JD, HJD, JDC J-Frame HMCP 10.00 10.00 4.12 4.12 F3S03 F3S03 400A 400A K-Frame/DK, KDB, KD, HKD K-Frame HMCP 10.12 12.45 5.50 5.50 F4S03 F4S03 600A 600A L-Frame/LD, HLD, LDC L-Frame HMCP 10.75 12.50 8.25 8.25 F7S04 800A M-Frame/MD, MDS 16.00 8.25 F5S04 1200A N-Frame/ND, HND, NDC 16.00 8.25 F6S04 2500A R-Frame/RD, CRD, RDC 16.00 15.50 -Catalog numbers for complete mechanisms include a flange-mounted handle, flexible shaft and circuit breaker mechanism. -The last digit of the catalog number denotes the length of shaft (F1S03 = 3 foot shaft). The F, J, K frame Flex Shafts are available in 3-foot to 10-foot lengths. The L, N, R frame Flex Shafts are available in 4-foot to 6-foot lengths. Space Occupied by Disconnect *The Flex Shaft system allows the circuit breaker to be positioned independent from the flange-mounted handle mechanism. *Refer to National Electrical Code 1999, article 430-10(b) for wiring space "W" required for line side conductors. *Choose the length of shaft based on placement of the circuit breaker in the enclosure ensuring a 4" minimum bending radius for the Flex Shaft. *Space occupied by circuit breaker is determined by overall height "X", width "Y", wire bend space "W" and location "F" as selected from right to left. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 D I S C O N N E C T W I R I N G S PA C E I N F O R M AT I O N Cutler-Hammer Type SM Safety Handle Mechanisms for C-H/Westinghouse Circuit Breakers Handle Mechanism SM101PR SM150R SM250JR SM400KR SM400PR SM600R SM800R SM8000PR Use with Circuit Breaker Floor Mount Enclosures Type 12 When When A = 60 A = 72 W W Space Occupied E F FB Tri-Pac F Frame EHD, FDB, FD, HFD, FDC J Frame JDB, JD, HJD, JDC K Frame DK, KDB, KD, HKD LA Tri-Pac L Frame LD, HLD, LDC M Frame MD, MDS, HMD NB Tri-Pac 8.00 8.00 8.50 9.06 14.44 8.81 10.68 16.81 5.38 5.38 7.50 7.50 9.75 7.62 9.75 9.75 6.50 6.50 NA NA NA NA NA NA Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W 12.00 12.00 9.50 9.12 9.25 NA NA NA 10.50 10.50 8.00 7.62 7.75 NA NA NA Floor Mount Disconnects: For Floor Mount Disconnects: "D" = 7.31 when "A" = 60 for up to type SM200 "D" = 12.81 when "A" = 72 for up to type SM200 "D" = 6.88 when "A" = 60 for type SM200 and larger "D" = 12.38 when "A" = 72 for type SM200 and larger reestanding Disconnects: For Freestanding Disconnects: "D" = 11.31 when "A" = 72 for up to type SM200 "D" = 16.81 when "A" = 84 for up to type SM200 "D" = 19.81 when "A" = 90 for up to type SM200 "D" = 10.88 when "A" = 72 for type SM200 and larger "D" = 16.38 when "A" = 84 for type SM200 and larger "D" = 19.38 when "A" = 90 for type SM200 and larger 16.00 16.00 13.50 13.12 13.25 12.38 9.66 9.66 19.00 19.00 16.50 16.12 16.25 15.38 12.66 12.66 Flange-Mounted Disconnect Enclosures Wire Bend Space Above Disconnect Wire Bend Space Above Disconnect General Electric Type STDA Disconnect Switch Operators Mechanism Space Occupied E F Double Door Enclosures Type 12 When When A = 60 A = 72 W W Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W Amp Rating Fuse Clip Fuse Class TD0M1A TD0M1A TD0M1B TD0M1B TD0M1B 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 60A-250V 60A-600V NA H,R H,R H,R H,R 6.88 6.88 11.50 11.50 11.50 5.38 5.38 5.38 5.38 5.38 8.38 8.38 8.38 8.38 8.38 13.88 13.88 13.88 13.88 13.88 12.38 12.38 12.38 12.38 12.38 17.88 17.88 17.88 17.88 17.88 20.88 20.88 20.88 20.88 20.88 TD0M1A TD0M1B TD0M1B TD0M1B TD0M1B 60A 60A 60A 60A 60A NO FUSE 60A-250V 60A-600V 100A-250V 100A-600V NA H,R H,R H,R H,R 6.88 11.50 11.50 11.50 11.50 5.38 5.38 5.38 5.38 5.38 8.38 8.38 8.38 8.38 8.38 13.88 13.88 13.88 13.88 13.88 12.38 12.38 12.38 12.38 12.38 17.88 17.88 17.88 17.88 17.88 20.88 20.88 20.88 20.88 20.88 TD0M1A TD0M1B TD0M1B TD0M1B TD0M1B 100A 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 200A-250V 200A-600V NA H,R H,R H,R H,R 6.88 11.50 11.50 11.50 11.50 5.38 5.38 5.38 5.38 5.38 8.38 8.38 8.38 8.38 8.38 13.88 13.88 13.88 13.88 13.88 12.38 12.38 12.38 12.38 12.38 17.88 17.88 17.88 17.88 17.88 20.88 20.88 20.88 20.88 20.88 TD0M2 TD0M2 TD0M2 200A 200A 200A NO FUSE 200A-250V 200A-600V NA H,R H,R 7.00 15.38 15.38 9.25 9.25 9.25 5.69 5.69 5.69 11.19 11.19 11.19 9.69 9.69 9.69 15.19 15.19 15.19 18.19 18.19 18.19 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 85 TYPE 12 F L O O R M O U N T & F R E E S TA N D I N G ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Wire Bend Space Above Disconnect General Electric Type STDA Operators for Circuit Breakers Mechanism Floor Mount Enclosures Type 12 When When A = 60 A = 72 W W Space Occupied E F Freestanding Enc Type 12 When When A = 72 A = 84 W W Flange-Mounted Disconnect Enclosures Amp Rating Frame Type SD0M1A SD0M1A TD0M1B TD0M1B TD0M1C TD0M1D 150A 150A 150A 150A 150A 150A TEB, TED, THED TEC TB1 TEC, TECL TEL THLC1 6.88 6.88 11.50 11.50 6.88 6.88 5.38 5.38 5.38 5.38 5.38 5.38 7.24 7.24 7.24 7.24 7.24 5.87 12.74 12.74 12.74 12.74 12.74 11.37 11.24 11.24 11.24 11.24 11.24 9.87 16.74 16.74 16.74 16.74 16.74 15.37 TD0M3 TD0M3 225A 225A TFJ TFK, THFK, TFL 10.38 10.38 5.88 5.88 6.81 6.81 12.31 12.31 10.81 10.81 16.31 16.31 TD0M4 TD0M4 400A 600A TJJ, TJK4, THJK4, TJL4V TJK6, THJK6, TJ4V, TJL4V 8.25 8.25 9.50 9.50 NA NA 11.41 11.41 9.91 9.91 15.41 15.41 TD0M5 400A TB4, TJH6S 14.25 9.50 NA 11.41 9.91 15.41 TD0M6 TD0M6 TD0M6 TD0M6 225A 400A 800A-1200A 1200A TLB2, THLC2 TLB4, THLC4 TKNA, THKMA, TK4V TK4V, THK4V 11.75 11.75 11.75 11.75 9.50 9.50 9.50 9.50 NA NA NA NA 10.85 9.47 NA NA NA NA NA NA 14.85 13.47 NA NA TD0M7 TD0M7 TD0M7 600A 800A 1200A TB6 TB8 TKL12S 18.12 18.12 18.12 9.50 9.50 9.50 NA NA NA NA NA NA NA NA NA 11.75 11.75 NA SD0M1A SD0M3 SD0M4 150A 250A 600A SPECTRA SE150 SPECTRA SF250 SPECTRA SG600 6.88 10.38 10.00 5.38 5.88 7.12 7.24 6.81 NA 12.74 11.38 8.68 11.24 10.81 NA 16.74 16.31 12.68 For Floor Mount Disconnects: For Floor Mount Disconnects: "D" = 7.88 when "A" = 60 "D" = 13.38 when "A" = 72 For Freestanding Disconnects: For Freestanding Disconnects: "D" = 11.88 when "A" = 72 "D" = 17.38 when "A" = 84 "D" = 20.38 when "A" = 90 General Electric Circuit Breakers with Spectra Flex Cable Operators Frame Size Max Amp Rating Circuit Breaker Height "X" Circuit Breaker Width "Y" E150 SE150 150A 150A 6.31 6.31 4.12 4.12 SF250 250A 10.12 4.12 SG600 600A 10.09 5.50 SK1200 1200A 15.50 8.25 See enclosure size tables for enclosures that will accept these devices Frame Size Breaker Mechanism E150 Flange Mounting Handle Operating Cable* SC0M1A SCH1 SE150/SF250 SCOM1EF SCH1 SC3L SC3L SG600 SCOM1G SCH1 SC3L SK1200 SCOM1K SCH3K SC3H *Operating cables are available in 3-foot to 10-foot lengths. (The number 3 in the catalog number denotes 3-foot cable). Space Occupied by Circuit Breaker *The General Electric Spectra-Flex cable operators allow a Circuit Breaker to be positioned independent from the flange-mounted handle mechanism. *Refer to National Electrical Code 1996 1999 article 430-10(b) for wiring space "W" for line side conductors. *Choose the operating cable length based on placement of circuit breaker in the enclosure ensuing a 3" minimum bending radius for the cable. *Space occupied by circuit breaker is determined by overall circuit breaker size ("X" height and "Y" width) plus "W" wire bend space and location "F" (from right to left) as selected. For Floor Mount Disconnects: "D" = 7.88 when "A" = 60 "D" = 13.38 when "A" = 72 For Freestanding Disconnects: "D" = 11.88 when "A" = 72 "D" = 17.38 when "A" = 84 "D" = 20.38 when "A" = 90 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 D I S C O N N E C T W I R I N G S PA C E I N F O R M AT I O N Switch Amp Rating Fuse Clip Fuse Class Disconnect Height "X" Disconnect Width "Y" MCS603R MCS603R MCS603R MCS603R 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 30A-600V NA H,K,R H,K,R J 5.52 8.11 10.11 8.48 6.13 6.13 6.13 6.13 MCS606R MCS606R MCS606R MCS606R 60A 60A 60A 60A NO FUSE 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R J 5.52 7.86 10.38 8.36 6.13 6.13 6.13 6.13 MCS610R MCS610R MCS610R MCS610R 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J 7.59 11.85 13.85 10.60 7.38 7.38 7.38 7.38 MCS620R MCS620R MCS620R MCS620R 200A 200A 200A 200A NO FUSE 200A-250V 200A-600V 200A-600V NA H,K,R H,K,R J 9.02 14.70 17.20 13.32 9.17 9.17 9.17 9.17 Flange-Mounted Disconnect Enclosures I-T-E Disconnect Switches for Max-Flex Operators See enclosure size table for enclosures that accept these devices Floor Mount enclosures that are 24" deep require a 48" Max-Flex cable (minimum) . I-T-E Circuit Breakers with Max-Flex Operators Complete (1) (2) Operator Mechanism Circuit Breaker Frame Maximum Amp Rating Circuit Breaker Height "X" Circuit Breaker Width "Y" Circuit Breaker Type FH0E036 FH0E36 ED CED 125A 125A 6.34 9.58 3.00 3.00 ED2, ED4, ED6, HED4, HED6 CED6 FH0F036 FH0J036 FD CFD 250A 250A 9.50 14.25 4.50 4.50 FXD6-A, FD6-A, HFD6. FXD6-ETJ, HHFD6, HHFXD6 CFD6, CFD6-ETI FH0J036 FH0J036 JD CJD 400A 400A 11.00 17.86 7.50 7.50 JXD2, JXD6, JD6, HJD6, HHJD6, HHJXD6, JXD6-ETI CJD6, CJD6-ETI FH0J036 FH0J036 LD CLD 600A 600A 11.00 17.86 7.50 7.50 LXD6, LD6, HLD6, HHLD6, HHLDX6, LXD6-ETI CLD6, CLD6-ETI FH0LM036 LMD 800A 16.00 9.00 LMD6, LMXD6, HLMD6, HLMXD6, LMXD6-ETI Mechanisms and Circuit Breakers listed above will fit any enclosure (1)- The last 3 digits of operator mechanism number indicate cable length in inches. 48" cables are available for ED, FD, JD/LD operators, and 60" cables for MD/ND, PD/RD operators. (2)- For Type 4 applications order handle, cable and circuit breaker operator separately or Floor Mount Disconnects: "D" = 7.88 when "A" = 60 "D" = 13.38 when "A" = 72 r Freestanding Disconnects: "D" = 11.88 when "A" = 72 "D" = 17.38 when "A" = 84 "D" = 20.38 when "A" = 90 For Floor Mount Disconnects: For Freestanding Disconnects: Space Occupied by Disconnect *The I-T-E Max-Flex cable system allows the disconnect to be positioned independent from the flange-mounted handle operator. *Refer to National Electrical Code 1999 article 430-10(b) for wiring space "W" required for line side conductors. *Refer to Siemens I-T-E installation instructions for limits on disconnect location when using a 36" or 48" Max-Flex cables. *Space occupied by disconnect is determined by overall disconnect height "X", width "Y", wire bend space "W", and location "F" from right to left as selected. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 87 TYPE 12 F L O O R M O U N T & F R E E S TA N D I N G ENCLOSURE FOR FLANGEMOUNTED DISCONNECT Square D Class 9422 Variable Depth Disconnects Switches Wire Bend Space Above Disconnect Square D Class 9422 Variable Depth Disconnects Switches Flange-Mounted Disconnect Enclosures Type Number Space Occupied E F Double Door Enclosures Type 12 When When A = 60 A = 72 W W Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W Amp Rating Fuse Clip Fuse Class TCN-30 TCF-30 TCF-33 TCF-33 TCF-33 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 60A-250V 30A-600V NA H,K,R H,K,R H,K,R J 3.80 5.53 8.15 6.15 5.53 6.97 6.97 6.97 6.97 6.97 6.75 6.75 6.75 6.75 6.75 10.75 10.75 10.75 10.75 10.75 12.25 12.25 12.25 12.25 12.25 16.25 16.25 16.25 16.25 16.25 19.25 19.25 19.25 19.25 19.25 TDN-60 TDF-60 TDF-60 TDF-63 TDF-63 60A 60A 60A 60A 60A NO FUSE 30A-600V 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R H,K,R J 3.80 8.15 6.15 8.65 5.53 6.97 6.97 6.97 6.97 6.97 6.75 6.75 6.75 6.75 6.75 10.75 10.75 10.75 10.75 10.75 12.25 12.25 12.25 12.25 12.25 16.25 16.25 16.25 16.25 16.25 19.25 19.25 19.25 19.25 19.25 TEN-10 TEF-10 TEF-10 TEF-10 TEF-13 100A 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V 200A-600V NA H,K,R H,K,R J J 3.80 8.25 10.25 7.05 NA 6.97 6.97 6.97 6.97 NA 6.62 6.62 6.62 6.62 6.62 10.62 10.62 10.62 10.62 10.62 12.13 12.13 12.13 12.13 12.13 16.13 16.13 16.13 16.13 16.13 19.13 19.13 19.13 19.13 19.13 TC-1 TC-2 TC-3 TC-3 TC-3 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 60A-250V 30A-600V NA H,K,R H,K,R H,K,R J 5.75 5.75 7.75 5.88 5.75 6.12 6.12 6.12 6.12 6.12 5.88 5.88 5.88 5.88 5.88 9.88 9.88 9.88 9.88 9.88 11.38 11.38 11.38 11.38 11.38 15.38 15.38 15.38 15.38 15.38 18.38 18.38 18.38 18.38 18.38 TD-1 TD-2 TD-2 TD-3 TD-3 60A 60A 60A 60A 60A NO FUSE 30A-600V 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R H,K,R J 6.38 8.50 6.50 9.00 6.38 6.75 6.75 6.75 6.75 6.75 6.75 6.75 6.75 6.75 6.75 10.75 10.75 10.75 10.75 10.75 12.25 12.25 12.25 12.25 12.25 16.25 16.25 16.25 16.25 16.25 19.25 19.25 19.25 19.25 19.25 TE-1 TE-2 TE-2 TE-2 TE-3 100A 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V 200A-600V NA H,K,R H,K,R J J 4.75 7.50 9.50 6.25 13.75 8.50 8.50 8.50 8.50 8.50 6.50 6.50 6.50 6.50 6.50 10.50 10.50 10.50 10.50 10.50 12.00 12.00 12.00 12.00 12.00 16.00 16.00 16.00 16.00 16.00 19.00 19.00 19.00 19.00 19.00 TF-1 TF-2 TF-2 TF-2 TF-3 200A 200A 200A 200A 200A NO FUSE 200A-250V 200A-600V 200A-600V 400A-600V NA H,K,R H,K,R J J 5.50 11.50 14.00 10.12 14.50 11.75 11.75 11.75 11.75 11.75 5.12 5.12 5.12 5.12 5.12 9.12 9.12 9.12 9.12 9.12 10.62 10.62 10.62 10.62 10.62 14.62 14.62 14.62 14.62 14.62 17.62 17.62 17.62 17.62 17.62 Wire Bend Space Above Disconnect Square D Class 9422 Variable Depth Operators-Circuit Breakers Type Number RG-1 RG-1 RN-1 RP-1 RR-1 RT-1 RT-1 Amp Rating Fuse Clip 75A 100A 100A 250A 400A 800A 1000A GJL GJL FAL, FHL KAL, KHL LAL, LHL, Q4L MEL, MXL MAL, MHL Space Occupied E F 3.53 3.53 5.12 7.12 7.62 9.12 9.12 Double Door Enclosures Type 12 When When A = 60 A = 72 W W 3.87 3.87 5.38 5.75 8.88 12.00 12.00 Floor Mount Disconnects: For FloorFor Mount Disconnects: "D" = 7.88 when "A" = 60 "D" = 13.38 when "A" = 72 For Freestanding Disconnects: For Freestanding Disconnects: "D" = 11.88 when "A" = 72 "D" = 17.38 when "A" = 84 "D" = 20.38 when "A" = 90 6.69 6.69 6.88 7.56 NA NA NA 12.19 12.19 12.38 13.06 8.75 NA NA Freestanding Enclosures Type 12 When When When A = 72 A = 84 A = 90 W W W 10.69 10.69 10.88 11.56 NA NA NA 16.19 16.19 16.38 17.06 12.75 12.62 12.62 19.19 19.19 19.38 20.06 15.75 15.62 15.62 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 D I S C O N N E C T W I R I N G S PA C E I N F O R M AT I O N Switch Amp Rating Fuse Clip Fuse Class Disconnect Height "X" Disconnect Width "Y" TCN-30 TCF-30 TCF-33 TCF-33 TCF-33 30A 30A 30A 30A 30A NO FUSE 30A-250V 30A-600V 60A-250V 30A-600V NA H,K,R H,K,R H,K,R J 5.90 7.50 10.15 8.15 7.50 6.20 6.20 6.20 6.20 6.20 TDN-60 TDF-60 TDF-60 TDF-63 TDF-63 60A 60A 60A 60A 60A NO FUSE 30A-600V 60A-250V 60A-600V 60A-600V NA H,K,R H,K,R H,K,R J 5.90 10.15 8.15 10.65 7.50 6.20 6.20 6.20 6.20 6.20 TEN-10 TEF-10 TEF-10 TEF-10 100A 100A 100A 100A NO FUSE 100A-250V 100A-600V 100A-600V NA H,K,R H,K,R J 5.90 10.35 12.35 10.35 6.20 6.20 6.20 6.20 Flange-Mounted Disconnect Enclosures Square D Class 9422 Disconnect Switches used with Cable Mechanism 9422-CFT30* and 9422A-1 Handle Mechanism See enclosure size table for enclosures that accept these devices . *Use switches listed above with appropriate cable mechanism and 9422-A1 handle mechanism. Cable operators are available in 3-foot, 5-foot and 10-foot lengths. Numbers shown (30) are for 3-foot cables Square D Class 9422 Cable Mechanisms for Circuit Breakers Cable Type* Switch 9422 CGJ30 9422 CEJ30 9422 CFA30 9422 CKA30 9422 CLA30 Amp Rating Frame Type Circuit Breaker Height "X" 75A 100A 100A 250A 400A GJL GJL FAL, FHL KAL, KHL LAL, LHL, Q4L 4.75 4.75 6.00 8.00 11.00 See enclosure size table for enclosures that accept these devices. Use cable mechanism with appropriate circuit breaker and 9422-A1 handle mechanism. *Cable operators are available in 3-foot, 5-foot and 10-foot lengths. Numbers shown (30) are for 3-foot cables. Space Occupied by Disconnect Switch or Circuit Breaker -Space D cable mechanisms allow disconnect device to be positioned independent from the flange-mounted handle mechanism. -Refer to National Electrical Code 1999 article 430-10(b) for wiring space "W" required for line side conductors. -Choose cable mechanism length based on placement of disconnect in enclosure. See Square D Instruction Bulletin for minimum bend raduis for cable. -Space occupied by disconnect is determined by overall disconnect ("X" height and "Y" width) plus "W" wire bend space and location "F" (from right to left) as selected. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 89 JIC CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: • Fabricated in accordance with UL specifications from 14 gauge steel. • Continuously welded seams ground smooth. • Cover held in place by continuous hinge on one side and stainless steel external screw clamps on opposite side. • External mounting feet. Type 4, 12 & 13 Oiltight Enclosures • Neoprene gasket attached to cover with oil resistant adhesive. • Enclosures that are 6x4x3 and over have stand-offs provided for mounting optional panel or terminal kit. Finish: Austin JIC Continuous Hinge boxes are provided standard with an ANSI 61 gray polyester powder coating. Optional panel are painted white. Y Y 1 CLAMP USED WHEN "A" IS LESS THAN 8" .31 DIA. Options: • Special materials. • Special finishes. B-1.13 PANEL (Optional) A+1.50 • Custom box size or construction. A+.75 A-1.13 C+.44 A C .50 .38 .31 • Hasp for padlocking. .31 B+1.18 SECTION Y-Y B-2.00 B FRONT VIEW WITH NO COVER AND CLAMPS REMOVED INDUSTRY STANDARDS UL 50 UL 508 NEMA CUL Type Type Type Type 12 12 12 12 & 13 & 13 & 13 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 4, 12 & 13 Oiltight Enclosures JIC CONTINUOUS HINGE BOXES Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 91 JIC L I F T- O F F H I N G E B O X E S Austin JIC Lift-Off Hinge (JL) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: • Fabricated in accordance with UL specifications from 14 gauge steel. • Chain holds cover to box when cover is removed. • Continuously welded seams ground smooth. • Enclosures that are 6x4x3 and over have stand-offs provided for mounting optional panel. Type 4, 12 & 13 Oiltight Enclosures • Neoprene gasket attached to cover with oil resistant adhesive. • External mounting feet. • Cover held in place by stainless steel external screw clamps. Finish: .31 DIA. Y B-1.13 PANEL (Optional) A+1.50 A+.75 A-1.13 A Austin JIC Lift-Off Hinge boxes are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. .38 .31 .31 B-2.00 Y Options: B B+.50 COVER ATTACHED TO BOX BY SMALL CHAIN (NOT SHOWN). WHEN "B" = 8 OR MORE, 2 CLAMPS ARE USED AT THIS END FRONT VIEW WITH NO COVER AND CLAMPS REMOVED • Special materials. • Special finishes. • Custom box size or construction. C+.44 C .50 SECTION Y-Y INDUSTRY STANDARDS UL 50 UL 508 NEMA CUL Type Type Type Type 12 12 12 12 & 13 & 13 & 13 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-443JL AB-643JL AB-863.5JL 4x4x3 6x4x3 8x6x3 1/2 2 3 5 NA AB-64JP AB-86JP AB-444JL AB-644JL AB-664JL AB-1084JL 4x4x4 6x4x4 6x6x4 10x8x4 5 2 3 8 NA AB-64JP AB-66JP AB-108JP AB-12105JL 12x10x5 12 AB-1210JP AB-14126JL AB-16146JL 14x12x6 16x14x6 16 21 AB-1412JP AB-1614JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures J I C L I F T- O F F H I N G E B O X E S Phone: 336.468.2851 800.288.2851 93 JIC SCREW COVER BOXES Austin JIC Screw Cover (JS) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They are designed for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Enclosures • Fabricated in accordance with UL specifications from 14 gauge steel. • Continuously welded seams ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. • External mounting feet. • Enclosures that are 6x4x3 and over are provided with stand-offs for mounting optional panel. • Cover attached with captivated screws threaded into sealed wells. Finish: Austin JIC Screw Cover boxes are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. .31 DIA. Y Y B-1.13 PANEL (Optional) A+1.50 A+.75 A-1.13 A .38 .31 .31 1.00 Options: B-2.00 B+.50 B • Special materials. FRONT VIEW WITH COVER REMOVED C+.44 • Special finishes. • Custom box size or construction. C .50 SECTION Y-Y INDUSTRY STANDARDS UL 50 UL 508 NEMA CUL Type Type Type Type 4, 4, 4, 4, 12 12 12 12 & 13 & 13 & 13 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-443JS AB-643JS AB-863.5JS 4x4x3 6x4x3 8x6x3 1/2 2 3 5 NA AB-64JP AB-86JP AB444JS AB-644JS AB-664JS AB-884JS AB-1084JS AB-10104JS 4x4x4 6x4x4 6x6x4 8x8x4 10x8x4 10x10x4 2 3 4 7 8 9 NA AB-64JP AB-66JP AB-88JP AB-108JP AB-1010JP AB-12105JS 12x10x5 11 AB-1210JP AB-866JS AB-1086JS AB-10106JS AB-12126JS AB-14126JS AB-16146JS 8x6x6 10x8x6 10x10x6 12x12x6 14x12x6 16x14x6 7 10 11 15 16 20 AB-86JP AB-108JP AB-1010JP AB-1212JP AB-1412JP AB-1614JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures JIC SCREW COVER BOXES Phone: 336.468.2851 800.288.2851 95 JIC NEMA 4 CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge NEMA 4 (JFH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They are designed for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Enclosures • Fabricated in accordance with UL specifications from 14 gauge steel. • Continuously welded seams ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. • External mounting feet. • Enclosures that are 6x4x3 and over are provided with stand-offs for mounting optional panel. • Stainless steel external screw clamps on three sides. • Stainless steel continuous hinge. Finish: .31 DIA. Y Y B-1.13 PANEL (Optional) Austin JIC Continuous Hinge NEMA 4 boxes are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. A+1.50 A+.75 A-1.13 A .38 .31 .31 B-2.00 B FRONT VIEW WITH NO COVER AND CLAMPS REMOVED C+.44 Options: C .50 • Special materials. B+1.18 • Special finishes. SECTION Y-Y 2.50 2.00 12x10 • Hasp for padlocking. 16x14 4x4 12x12 10x8 6x4 8x6 6x6 8x8 CL CL 10x10 14x12 2.50 2.00 1.50 1.50 2.50 2.50 1.50 1.50 CL CL INDUSTRY STANDARDS • Custom box size or construction. UL 50 UL 508 NEMA CUL Type Type Type Type 4, 4, 4, 4, 12 12 12 12 & 13 & 13 & 13 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-443JFH AB-643JFH AB-863.5JFH 4x4x3 6x4x3 8x6x3 1/2 2 3 6 NA AB-64JP AB-86JP AB-664JFH AB-1084JFH 6x6x4 10x8x4 4 9 AB-66JP AB-108JP AB-12105JFH 12x10x5 13 AB-1210JP AB-10106JFH AB-12126JFH AB-14126JFH AB-16146JFH 10x10x6 12x12x6 14x12x6 16x14x6 11 15 17 20 AB-1010JP AB-1212JP AB-1412JP AB-1614JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures JIC NEMA 4 CONTINUOUS HINGE BOXES Phone: 336.468.2851 800.288.2851 97 JIC NEMA 4 CLAMP COVER BOXES Austin JIC Clamp Cover NEMA 4 (JFC) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They are designed for indoor and outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Enclosures • Fabricated in accordance with UL specifications from 14 gauge steel. • Neoprene gasket attached to cover with oil resistant adhesive. • Continuously welded and ground smooth. • External mounting feet. • Cover held in place by stainless steel external screw clamps all four sides. • Enclosures that are 6x4x3 and over have stand-offs provided for mounting optional panel. Finish: .31 DIA. Y Y B-1.13 PANEL (Optional) Austin JIC Clamp Cover NEMA 4 boxes are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. A+1.50 A+.75 A-1.13 A .38 .31 .31 B-2.00 B FRONT VIEW WITH NO COVER AND CLAMPS REMOVED C+.44 Options: C .50 • Special materials. B+2.00 • Special finishes. SECTION Y-Y 2.50 2.00 • Custom box size or construction. 12x10 16x14 4x4 12x12 10x8 6x4 8x6 6x6 8x8 CL CL 10x10 14x12 2.50 2.00 1.50 1.50 2.50 2.50 1.50 CL CL INDUSTRY STANDARDS 1.50 UL 50 UL 508 NEMA CUL Type Type Type Type 4, 4, 4, 4, 12 12 12 12 & 13 & 13 & 13 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-443JFC AB-643JFC AB-863.5JFC 4x4x3 6x4x3 8x6x3 1/2 2 3 6 NA AB-64JP AB-86JP AB-664JFC AB-1084JFC 6x6x4 10x8x4 4 9 AB-66JP AB-108JP AB-12105JFC 12x10x5 12 AB-1210JP AB-14126JFC AB-16146JFC 14x12x6 16x14x6 17 21 AB-1412JP AB-1614JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures JIC NEMA 4 CLAMP COVER BOXES Phone: 336.468.2851 800.288.2851 99 JIC NEMA 4X CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge NEMA 4X (JHFX) boxes are Underwriters Laboratories Listed and are designed for housing electrical components in highly corrosive environments. They are designed for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Enclosures • Fabricated in accordance with UL specifications from 14 gauge Type 304 stainless steel. • Neoprene gasket attached to cover with oil resistant adhesive. • Continuously welded seams ground smooth. • External mounting feet. • Stainless steel external screw clamps. • Enclosures that are 6x4x3 and over have stainless steel stand-offs provided for mounting optional panel. • Stainless steel continuous hinge. Finish: .31 DIA. Y Y B-1.13 PANEL (Optional) Austin JIC Continuous Hinge NEMA 4X boxes are provided standard in Type 304 stainless steel. Optional panels are painted white or stainless steel panels are unpainted. A+1.50 A+.75 A-1.13 A .38 .31 .31 B-2.00 B FRONT VIEW WITH NO COVER AND CLAMPS REMOVED Options: C+.44 C .50 • Type 316 Stainless Steel. B+1.18 SECTION Y-Y 2.50 2.00 • Custom box size or construction. • Hasp for padlocking. 12x10 16x14 4x4 12x12 10x8 6x4 8x6 6x6 8x8 CL CL 10x10 14x12 2.50 2.00 1.50 1.50 2.50 2.50 1.50 CL CL INDUSTRY STANDARDS 1.50 UL 50 UL 508 NEMA CUL Types Types Types Types 4, 4, 4, 4, 4X, 4X, 4X, 4X, 12 12 12 12 & & & & 13 13 13 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-863.5JHFX 8x6x3 1/2 6 AB-86JP AB-664JHFX AB-884JHFX AB-1084JHFX 6x6x4 8x8x4 10x8x4 5 7 9 AB-66JP AB-88JP AB-108JP AB-12105JHFX 12x10x5 13 AB-1210JP AB-14126JHFX AB-16146JHFX 14x12x6 16x14x6 17 20 AB-1412JP AB-1614JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures JIC NEMA 4X CONTINUOUS HINGE BOXES Phone: 336.468.2851 800.288.2851 101 JIC NEMA 4X CLAMP COVER BOXES Austin JIC Clamp Cover NEMA 4X (JFCX) boxes are Underwriters Laboratories Listed and are designed for housing electrical components in highly corrosive environments. They are designed for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: • Fabricated in accordance with UL specifications from 14 gauge Type 304 stainless steel. • External mounting feet. • Enclosures that are 6x4x3 and over have stainless steel stand-offs provided for mounting optional panel. • Continuously welded seams and ground smooth. Type 4, 12 & 13 Oiltight Enclosures • Neoprene gasket attached to cover with oil resistant adhesive. • Cover held in place by stainless steel external screw clamps. Finish: .31 DIA. Y Y B-1.13 PANEL (Optional) Austin JIC Clamp Cover NEMA 4X boxes are provided standard in Type 304 stainless steel. Optional panels are painted white or stainless steel panels are unpainted. A+1.50 A+.75 A-1.13 A .38 .31 .31 B-2.00 B FRONT VIEW WITH NO COVER AND CLAMPS REMOVED C+.44 Options: C .50 • Type 316 Stainless Steel. B+2.00 SECTION Y-Y 2.50 2.00 • Custom box size or construction. 12x10 16x14 4x4 12x12 10x8 6x4 8x6 6x6 8x8 CL CL 10x10 14x12 2.50 2.00 1.50 1.50 2.50 2.50 1.50 CL CL INDUSTRY STANDARDS 1.50 UL 50 UL 508 NEMA CUL Types Types Types Types 4, 4, 4, 4, 4X, 4X, 4X, 4X, 12 12 12 12 & & & & 13 13 13 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-863.5JFCX 8x6x3 1/2 6 AB-86JP AB-664JFCX AB-884JFCX AB-1084JFCX 6x6x4 8x8x4 10x8x4 5 7 9 AB-66JP AB-88JP AB-108JP AB-12105JFCX 12x10x5 13 AB-1210JP AB-12126JFCX AB-14126JFCX 12x12x6 14x12x6 15 17 AB-1212JP AB-1412JP AB-16146JFCX 16x14x6 20 AB-1614JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures JIC NEMA 4X CLAMP COVER BOXES Phone: 336.468.2851 800.288.2851 103 JIC ALUMINUM CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge aluminum (JHA) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: • Fabricated in accordance with UL specifications from code gauge Type 5052 H-32 aluminum. • External mounting feet. • Cover held in place by external screw clamps and aluminum continuous hinge. • Enclosures that are 6x4x3 and over have aluminum stand-offs provided for mounting optional panel. Type 4, 12 & 13 Oiltight Enclosures • Continuously welded seams ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. Finish: .31 DIA. Y Y B-1.13 PANEL (Optional) A+1.50 A+.75 A-1.13 Austin JIC continuous hinge aluminum boxes are provided standard in Type 5052 H-32 aluminum. Optional aluminum panels are unpainted and optional steel panels are painted white. A .38 .31 .31 B-2.00 Options: B 1 CLAMP USED WHEN "A" IS LESS THAN 8" • Custom box size or construction. FRONT VIEW WITH NO COVER AND CLAMPS REMOVED • Hasp for padlocking. C+.44 C .50 B+1.18 SECTION Y-Y INDUSTRY STANDARDS UL 50 UL 508 NEMA CUL Type Type Type Type 12 12 12 12 & 13 & 13 & 13 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-643JHA AB-863.5JHA 6X4X3 8x6x3 1/2 3 2 AB-64JP AB-86JP AB-664JHA AB-1084JHA 6x6x4 10x8x4 2 3 AB-66JP AB-108JP AB-12105JHA 12x10x5 5 AB-1210JP AB-14126JHA AB-16146JHA 14x12x6 16x14x6 7 9 AB-1412JP AB-1614JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures JIC ALUMINUM CONTINUOUS HINGE BOXES Phone: 336.468.2851 800.288.2851 105 JIC NEMA 4X ALUMINUM CLAMP COVER BOXES Austin JIC Clamp Cover NEMA 4X aluminum (JCA) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They are designed for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water, and damage from external ice formation. Construction: • Fabricated in accordance with UL specifications from code gauge Type 5052 H-32 aluminum. • External mounting feet. • Enclosures that are 6x4x3 and over have aluminum stand-offs provided for mounting optional panel. Type 4, 12 & 13 Oiltight Enclosures • Cover is held in place by external screw clamps on all four sides. • Continuously welded seams ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. Finish: .31 DIA. Y Y B-1.13 PANEL (Optional) Austin JIC Clamp Cover NEMA 4X aluminum boxes are provided standard in Type 5052 H-32 aluminum. Optional aluminum panels are unpainted and optional steel panels are painted white. A+1.50 A+.75 A-1.13 A .38 .31 .31 B-2.00 B FRONT VIEW WITH NO COVER AND CLAMPS REMOVED C+.44 C .50 Options: • Custom box size or construction. B+2.00 SECTION Y-Y 2.50 2.00 12x10 16x14 4x4 12x12 10x8 6x4 8x6 6x6 8x8 CL CL 10x10 14x12 2.50 2.00 1.50 1.50 2.50 2.50 1.50 CL CL INDUSTRY STANDARDS 1.50 UL 50 UL 508 NEMA CUL Types Types Types Types 4, 4, 4, 4, 4X, 4X, 4X, 4X, 12 12 12 12 & & & & 13 13 13 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-863.5JCA 8x6x3 1/2 2 AB-86JP AB-664JCA AB-1084JCA 6x6x4 10x8x4 2 3 AB-66JP AB-108JP AB-12106JCA AB-14126JCA AB-16146JCA 12x10x6 14x12x6 16x14x6 5 7 9 AB-1210JP AB-1412JP AB-1614JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures JIC NEMA 4X ALUMINUM CLAMP COVER BOXES Phone: 336.468.2851 800.288.2851 107 S M A L L O I LT I G H T E N C L O S U R E S Austin small oiltight (STE) enclosures are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: • Fabricated from 14 gauge steel. • Stand-offs provided for mounting optional panel. • Door attached by continuous hinge and captivated screws threaded into sealed wells. • Continuously welded seams ground smooth. Type 4, 12 & 13 Oiltight Enclosures • Neoprene gasket attached to door with oil resistant adhesive. • External mounting feet. Finish: Austin small oiltight enclosures are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. .31 DIA. Y B-1.13 Y A+1.50 A+.75 A-1.13 A .38 .31 .31 1.00 Options: B-2.00 B • Special materials. FRONT VIEW WITH NO COVER AND NO HINGE • Special finishes. C+.44 • Custom box size or construction. C .50 • Hasp for padlocking. SECTION Y-Y INDUSTRY STANDARDS UL 50 UL 508 NEMA CUL Type Type Type Type 12 12 12 12 & 13 & 13 & 13 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Enclosure Size (AxBxC) Weight Panel Catalog Number AB-664STE AB-864STE AB-884STE AB-1084STE AB-10104STE AB-12104STE 6x6x4 8x6x4 8x8x4 10x8x4 10x10x4 12x10x4 4 5 6 7 8 10 AB-66JP AB-86JP AB-88JP AB-108JP AB-1010JP AB-1210JP AB-866STE AB-886STE AB-1086STE AB-10106STE AB-12106STE AB-12126STE AB-14126STE 8x6x6 8x8x6 10x8x6 10x10x6 12x10x6 12x12x6 14x12x6 7 8 9 10 12 14 16 AB-86JP AB-88JP AB-108JP AB-1010JP AB-1210JP AB-1212JP AB-1412JP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Type 4, 12 & 13 Oiltight Enclosures S M A L L O I LT I G H T E N C L O S U R E S Phone: 336.468.2851 800.288.2851 109 L A R G E O I LT I G H T E N C L O S U R E S Austin large oiltight (JXL) enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, instruments, and terminals. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Standard plastic self-adhesive print pocket. • Continuously welded seams ground smooth. • Standard collar studs provided for mounting optional panel. Type 4, 12 & 13 Oiltight Enclosures • Door attached by continuous hinge and captivated screws threaded into sealed wells. • External mounting feet. • Neoprene gasket attached to door with oil resistant adhesive. Finish: Austin large oiltight enclosures are provided standard with an ANSI 61 gray polyester powder coating. Optional panels are painted white. OMIT CENTER SCREW IF "A" IS LESS THAN 31" Y Y .43 DIA. .63 PANEL (Optional) Options: B-3.00 B+.56 A-3.00 • Special materials. A • Special finishes. C+.50 .88 OMIT CENTER STUDS C IF "A" IS LESS THAN 31" • Custom box size or construction. 1.00 .88 .75 SECTION Y-Y B-6.00 B FRONT VIEW WITH NO COVER AND NO HINGE INDUSTRY STANDARDS UL 50 UL 508 NEMA CUL Type Type Type Type 12 12 12 12 & 13 & 13 & 13 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number O I LT I G H T Enclosure Size (AxBxC) Weight Panel Catalog Number AB-20167JXL AB-20207JXL AB-24207JXL AB-24247JXL AB-30207JXL AB-30247JXL AB-36247JXL 20x16x7 20x20x7 24x20x7 24x24x7 30x20x7 30x24x7 36x24x7 31 36 41 48 49 58 66 AB-2016TP AB-2020TP AB-2420TP AB-2424TP AB-3020TP AB-3024TP AB-3624TP AB-20169JXL AB-20209JXL AB-24209JXL AB-24249JXL AB-30209JXL 20x16x9 20x20x9 24x20x9 24x24x9 30x20x9 35 36 47 52 54 AB-2016TP AB-2020TP AB-2420TP AB-2424TP AB-3020TP Catalog Number ENCLOSURES Enclosure Size (AxBxC) Weight Panel Catalog Number AB-30249JXL AB-36249JXL AB-36309JXL AB-42309JXL AB-42369JXL 30x24x9 36x24x9 36x30x9 42x30x9 42x36x9 66 76 90 102 121 AB-3024TP AB-3624TP AB-3630TP AB-4230TP AB-4236TP AB-242411JXL AB-362411JXL AB-483611JXL 24x24x11 36x24x11 48x36x11 57 80 155 AB-2424TP AB-3624TP AB-4836TP AB-302413JXL AB-363013JXL 30x24x13 36x30x13 72 104 AB-3024TP AB-3630TP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Type 4, 12 & 13 Oiltight Enclosures LARGE 111 AUSTIN S TA N D A R D P U S H B U T T O N ENCLOSURES Austin standard pushbutton enclosures are Underwriters Laboratories Listed and are designed to house standard oiltight switches, pilot lights, and pushbutton switches. They provide a degree of protection against dust, dirt, oil, and water. Construction: • Fabricated from 14 gauge steel. • External mounting feet. • Continuously welded seams ground smooth. • Standard “4-way” 30mm pushbutton holes. • Neoprene gasket attached to cover with oil resistant adhesive. • Cover held in place by captivated screws threaded into sealed wells. Finish: Pushbutton Enclosures & Consolets Y Austin standard pushbutton enclosures are provided standard with an ANSI 61 gray polyester powder coating. Y A+1.50 2.25 A+.75 A 2.25 .38 2.38 1.00 B-2.00 2.25 2.38 B FRONT VIEW WITH COVER REMOVED C+.44 C Options: SECTION Y-Y • Special materials. HOLE ARRANGEMENT • Special finishes. A-1 B-1 B-2 C-1 C-2 • Custom box size or construction. C-3 D-1 D-3 D-4 E-1 E-4 E-5 NOTE: G-1 HAS 1/2" ADDED ON EACH SIDE OF THE CENTER HOLE. H-1 HAS 1" ADDED BETWEEN THE TWO CENTER HOLES. F-1 • “4-way” 22mm pushbutton holes. G-1 H-1 J-1 K-1 INDUSTRY STANDARDS UL 50 Types 4, 12 & 13 NEMA Types 4, 12 & 13 CUL Types 4, 12 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 A U S T I N S TA N D A R D P U S H B U T T O N E N C L O S U R E S Catalog Number AB-A1NPB AB-B1NPB AB-B2NPB AB-C1NPB AB-C2NPB AB-C3NPB AB-D1NPB AB-D3NPB AB-D4NPB AB-E1NPB AB-E4NPB AB-E5NPB AB-F1NPB AB-G1NPB AB-H1NPB AB-J1NPB AB-K1NPB Enclosure Size (AxBxC) Holes Hole Arrangement Weight 3 1/2x3 1/2x3 6 3/4x3 1/2x3 6 3/4x6 3/4x3 9x3 1/2x3 9x6 3/4x3 9x9x3 11 1/4x3 1/2x3 11 1/4x9x3 11 1/4x11 1/4x3 13 1/2x3 1/2x3 13 1/2x11 1/4x3 13 1/2x13 1/2x3 15 3/4x3 1/2x3 19x3 1/2x3 21 1/4x3 1/2x3 23 1/2x3 1/2x3 25 3/4x3 1/2x3 1 2 4 3 6 9 4 12 16 5 20 25 6 7 8 9 10 A-1 B-1 B-2 C-1 C-2 C-3 D-1 D-3 D-4 E-1 E-4 E-5 F-1 G-1 H-1 J-1 K-1 2 2 4 3 5 7 4 8 9 5 11 13 6 6 8 8 8 Catalog Number AB-A1NBPB AB-B1NBPB AB-B2NBPB AB-C1NBPB AB-C2NBPB AB-C3NBPB AB-D1NBPB AB-D3NBPB AB-D4NBPB AB-E1NBPB AB-E4NBPB AB-E5NBPB AB-F1NBPB AB-G1NBPB AB-H1NBPB AB-J1NBPB AB-K1NBPB Enclosure Size (AxBxC) Weight 3 1/2x3 1/2x3 6 3/4x3 1/2x3 6 3/4x6 3/4x3 9x3 1/2x3 9x6 3/4x3 9x9x3 11 1/4x3 1/2x3 11 1/4x9x3 11 1/4x11 1/4x3 13 1/2x3 1/2x3 13 1/2x11 1/4x3 13 1/2x13 1/2x3 15 3/4x3 1/2x3 19x3 1/2x3 21 1/4x3 1/2x3 23 1/2x3 1/2x3 25 3/4x3 1/2x3 2 2 4 3 5 7 4 8 9 5 11 13 6 6 8 8 8 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Pushbutton Enclosures & Consolets Blank Cover 113 AUSTIN EXTRA DEEP PUSHBUTTON ENCLOSURES Austin extra deep pushbutton enclosures are Underwriters Laboratories Listed and are designed to house standard oiltight switches, pilot lights, and stacked pushbutton units. They provide a degree of protection against dust, dirt, oil, and water. Construction: • Fabricated from 14 gauge steel. • External mounting feet. • Continuously welded seams ground smooth. • Standard “4-way” 30mm pushbutton holes. • Neoprene gasket attached to cover with oil resistant adhesive. • Cover held in place by captivated screws threaded into sealed wells. Finish: Pushbutton Enclosures & Consolets Y Austin extra deep pushbutton enclosures are provided standard with an ANSI 61 gray polyester powder coating. Y A+1.50 2.25 A+.75 A 2.25 .38 2.38 1.00 2.25 B-2.00 2.38 B FRONT VIEW WITH COVER REMOVED C+.44 C Options: • Special materials. SECTION Y-Y HOLE ARRANGEMENT • Special finishes. A-1 B-1 • Custom box size or construction. B-2 C-1 C-2 C-3 D-1 D-3 D-4 E-2 E-4 E-5 F-5 F-6 H-2 INDUSTRY STANDARDS UL 50 Types 4, 12 & 13 NEMA Types 4, 12 & 13 CUL Types 4, 12 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 • “4-way” 22mm pushbutton holes. Phone: 336.468.2851 800.288.2851 AUSTIN EXTRA DEEP PUSHBUTTON ENCLOSURES Catalog Number AB-A1DPB AB-B1DPB AB-B2DPB AB-C1DPB AB-C2DPB AB-C3DPB AB-D1DPB AB-D3DPB AB-D4DPB AB-E2DPB AB-E4DPB AB-E5DPB AB-F5DPB AB-F6DPB AB-H2DPB Enclosure Size (AxBxC) Holes Hole Arrangement Weight 3 1/2x3 1/2x4 1/2 6 3/4x3 1/2x4 1/2 6 3/4x6 3/4x4 1/2 9x3 1/2x4 1/2 9x6 3/4x4 1/2 9x9x4 1/2 11 1/4x3 1/2x4 1/2 11 1/4x9x4 1/2 11 1/4x11 1/4x4 1/2 13 1/2x6 3/4x4 1/2 13 1/2x11 1/4x4 1/2 13 1/2x13 1/2x4 1/2 15 3/4x13 1/2x4 1/2 15 3/4x15 3/4x4 1/2 20 1/4x6 3/4x4 1/2 1 2 4 3 6 9 4 12 16 10 20 25 30 36 16 A-1 B-1 B-2 C-1 C-2 C-3 D-1 D-3 D-4 E-2 E-4 E-5 F-5 F-6 H-2 3 3 6 4 6 8 5 9 10 9 13 15 17 21 10 Catalog Number AB-A1DBPB AB-B1DBPB AB-B2DBPB AB-C1DBPB AB-C2DBPB AB-C3DBPB AB-D1DBPB AB-D3DBPB AB-D4DBPB AB-E2DBPB AB-E4DBPB AB-E5DBPB AB-F5DBPB AB-F6DBPB AB-H2DBPB Enclosure Size (AxBxC) Weight 3 1/2x3 1/2x4 1/2 6 3/4x3 1/2x4 1/2 6 3/4x6 3/4x4 1/2 9x3 1/2x4 1/2 9x6 3/4x4 1/2 9x9x4 1/2 11 1/4x3 1/2x4 1/2 11 1/4x9x4 1/2 11 1/4x11 1/4x4 1/2 13 1/2x6 3/4x4 1/2 13 1/2x11 1/4x4 1/2 13 1/2x13 1/2x4 1/2 15 3/4x13 1/2x4 1/2 15 3/4x15 3/4x4 1/2 20 1/4x6 3/4x4 1/2 3 3 6 4 6 8 5 9 10 9 13 15 17 21 10 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Pushbutton Enclosures & Consolets Blank Cover 115 AUSTIN PENDANT PUSHBUTTON ENCLOSURES Austin pendant pushbutton enclosures are Underwriters Laboratories Listed and are designed to house standard oiltight switches, pilot lights, and pushbutton switches. They provide a degree of protection against dust, dirt, oil, and water. Construction: • Fabricated from 14 gauge steel. • Neoprene gasket attached to cover with oil resistant adhesive. • Has hub and hanger bracket at top for overhead wiring and support. • Standard “4-way” 30mm pushbutton holes. • Continuously welded and ground smooth. • Cover held in place by captivated screws threaded into sealed wells. Finish: Pushbutton Enclosures & Consolets Austin pendant pushbutton enclosures are provided standard with as ANSI 61 gray polyester powder coating. 2.25 2.75 .44 DIA. 1.50 A .50 1.00 2.25 2.25 2.00 B Options: C • Special materials. HOLE ARRANGEMENT • Special finishes. A-1 • Custom box size or construction. B-1 C-1 D-1 Note: G-1 has .5” added on each side of center hole. H-1 has 1” added between the two center holes. INDUSTRY STANDARDS • “4-way” 22mm pushbutton holes. E-1 F-1 G-1 H-1 UL 50 Types 4, 12 & 13 NEMA Types 4, 12 & 13 CUL Types 4, 12 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN PENDANT PUSHBUTTON ENCLOSURES AB-A1PPB AB-B1PPB AB-C1PPB AB-D1PPB AB-E1PPB AB-F1PPB AB-G1PPB AB-H1PPB Enclosure Size (AxBxC) Holes Hole Arrangement Weight "A" Dimension Conduit Hub 3 7/8x2 1/2x2 3/8 6 1/8x2 1/2x2 3/8 8 3/8x2 1/2x2 3/8 10 5/8x2 1/2x2 3/8 12 7/8x2 1/2x2 3/8 15 1/8x2 1/2x2 3/8 18 3/8x2 1/2x2 3/8 20 5/8x2 1/2x2 3/8 1 2 3 4 5 6 7 8 A-1 B-1 C-1 D-1 E-1 F-1 G-1 H-1 2 2 3 3 4 4 5 5 4 6 1/4 8 1/2 10 3/4 13 15 1/4 18 1/2 20 3/4 1/2 3/4 3/4 3/4 1 1 1 1 1/4 Pushbutton Enclosures & Consolets Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 117 AUSTIN SLIM-LINE PUSHBUTTON ENCLOSURES Austin slim-line pushbutton enclosures are Underwriters Laboratories Listed and are designed to house oiltight switches, pilot lights, and pushbutton switches where space is limited. They provide a degree of protection from dust, dirt, oil, and water. Construction: • Fabricated from 14 gauge steel. • External mounting feet. • Cover is held in place by captivated screws threaded into sealed wells. • Standard “4-way” 30mm pushbutton holes. • Continuously welded seams and ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. Finish: Pushbutton Enclosures & Consolets 2.75 .31 DIA. .38 A+.75 A Austin slim-line pushbutton enclosures are provided standard with as ANSI 61 gray polyester powder coating. .50 2.25 2.25 2.00 .38 C B Options: HOLE ARRANGEMENT • Special materials. • Special finishes. A-1 B-1 • Custom box size or construction. C-1 D-1 E-1 • “4-way” 22mm pushbutton holes. F-1 Note: G-1 has .5” added on each side of center hole. H-1 has 1” added between the two center holes. INDUSTRY STANDARDS G-1 H-1 UL 50 Types 4, 12 & 13 NEMA Types 4, 12 & 13 CUL Types 4, 12 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN SLIM-LINE PUSHBUTTON ENCLOSURES AB-A1MPB AB-B1MPB AB-C1MPB AB-D1MPB AB-E1MPB AB-F1MPB AB-G1MPB AB-H1MPB Enclosure Size (AxBxC) Holes Hole Arrangement Weight 3 7/8x2 1/2x2 3/8 6 1/8x2 1/2x2 3/8 8 3/8x2 1/2x2 3/8 10 5/8x2 1/2x2 3/8 12 7/8x2 1/2x2 3/8 15 1/8x2 1/2x2 3/8 18 3/8x2 1/2x2 3/8 20 5/8x2 1/2x2 3/8 1 2 3 4 5 6 7 8 A-1 B-1 C-1 D-1 E-1 F-1 G-1 H-1 1 2 2 3 3 4 4 8 Pushbutton Enclosures & Consolets Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 119 AUSTIN NEMA 4X PUSHBUTTON ENCLOSURES Austin NEMA 4X pushbutton enclosures are Underwriters Laboratories Listed and are designed to house oiltight switches, pilot lights, and pushbutton switches. They provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose directed water, and damage from external ice formation. They are also designed for use in areas where corrosion is a serious problem. Construction: • Fabricated from 14 gauge Type 304 steel. • External mounting feet. • Cover is held in place by captivated screws threaded into sealed wells. • Standard “4-way” 30mm pushbutton holes. • Continuously welded seams and ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. Pushbutton Enclosures & Consolets Finish: Y Y A+1.50 2.25 A+.75 Austin NEMA 4X pushbutton enclosures are provided standard in Type 304 stainless steel. A 2.25 .38 2.38 1.00 2.25 B-2.00 2.38 B FRONT VIEW WITH COVER REMOVED Options: • Type 316 stainless steel. C+.44 C • Custom box size or construction. SECTION Y-Y HOLE ARRANGEMENT • “4-way” 22mm pushbutton holes. A-1 B-1 C-1 C-2 C-3 D-1 INDUSTRY STANDARDS D-3 UL 50 Types 4, 12 & 13 NEMA Types 4, 12 & 13 CUL Types 4, 12 & 13 D-4 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN NEMA 4X PUSHBUTTON ENCLOSURES AB-A1FPB AB-B1FPB AB-C1FPB AB-C2FPB AB-C3FPB AB-D1FPB AB-D3FPB AB-D4FPB Enclosure Size (AxBxC) Holes Hole Arrangement Weight 3 1/2x3 1/2x3 6 3/4x3 1/2x3 9x3 1/2x3 9x6 3/4x3 9x9x3 11 1/4x3 1/2x3 11 1/4x9x3 11 1/4x11 1/4x3 1 2 3 6 9 4 12 16 A-1 B-1 C-1 C-2 C-3 D-1 D-3 D-4 2 2 3 6 7 4 8 10 Pushbutton Enclosures & Consolets Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 121 AUSTIN EXTRA LARGE HINGE COVER PUSH BUTTON ENCLOSURES WITH BACK Austin extra large hinge cover oiltight pushbutton enclosures are Underwriters Laboratories Listed and are designed to house oiltight switches, pilot lights, and pushbutton switches. They provide a degree of protection against dust, dirt, oil, and water. Construction: • Fabricated from 14 gauge steel. • Standard back panel. • Cover held in place by captivated screws threaded into sealed wells and a continuous hinge. • External mounting feet. • Standard “4-way” 30mm pushbutton holes. • Continuously welded seams ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. Finish: .31 DIA. Pushbutton Enclosures & Consolets Y Y B-1.13 2.25 A+1.50 A-1.13 A+.75 A+.50 A 2.25 .38 .31 .31 2.38 Austin hinge cover oiltight pushbutton enclosures are provided standard with an ANSI 61 gray polyester powder coating. Back panels are painted white. 1.00 .38 B-2.00 2.25 2.38 B B+.56 FRONT VIEW WITH NO COVER AND NO HINGE Options: C+.38 C .50 • Special materials. • Special finishes. SECTION Y-Y • Custom box size or construction. HOLE ARRANGEMENT • “4-way” 22mm pushbutton holes. C-2 C-3 D-3 D-4 E-4 E-5 F-5 F-6 HOLE ARRANGEMENT INDUSTRY STANDARDS UL 50 Type 12 & 13 NEMA Type 12 & 13 CUL Type 12 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN EXTRA LARGE HINGE COVER PUSHBUTTON ENCLOSURES WITH BACK AB-C2XPB AB-C3XPB AB-D3XPB AB-D4XPB AB-E4XPB AB-E5XPB AB-F5XPB AB-F6XPB Enclosure Size (AxBxC) Holes Hole Arrangement Weight 9x6 3/4x6 1/4 9x9x6 1/4 11 1/4x9x6 1/4 11 1/4x11 1/4x6 1/4 13 1/2x11 1/4x6 1/4 13 1/2x13 1/2x6 1/4 15 3/4x13 1/2x6 1/4 15 3/4x15 3/4x6 1/4 6 9 12 16 20 25 30 36 C-2 C-3 D-3 D-4 E-4 E-5 F-5 F-6 10 11 15 17 19 22 23 27 Pushbutton Enclosures & Consolets Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 123 AUSTIN SLOPING PUSHBUTTON ENCLOSURES Austin sloping pushbutton enclosures are Underwriters Laboratories Listed and are designed to house standard oiltight switches, pilot lights, and pushbutton switches where slanted control surfaces are desired. They provide a degree of protection against dust, dirt, oil, and water. Construction: • Fabricated from 14 gauge steel. • External mounting feet. • Continuously welded seams ground smooth. • Standard “4-way” 30mm pushbutton holes. • Neoprene gasket attached to cover with oil resistant adhesive. • Cover held in place by captivated screws threaded into sealed wells. B 2.250 Pushbutton Enclosures & Consolets G 1.00 2.250 .38 2.250 D A Finish: 1.00 D+.75 2.250 Austin sloping pushbutton enclosures are provided standard with an ANSI 61 gray polyester powder coating. F B .31 DIA. VIEW X-X .38 SECTION Y-Y X- 30˚ X C 10-32 SCREW w/RIVNUT 2.50 Y Y Options: • Special materials. • Special finishes. HOLE ARRANGEMENT A-1 A-2 B-2 B-6 B-5 • “4-way” 22mm pushbutton holes. A-4 A-3 B-4 B-3 B-8 C-3 D-3 D-4 D-5 E-5 INDUSTRY STANDARDS E-6 UL 50 Types 4, 12 & 13 NEMA Types 4, 12 & 13 CUL Types 4, 12 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number AB-A1SPB AB-A2SPB AB-A3SPB AB-A4SPB AB-B2SPB AB-B3SPB AB-B4SPB AB-B5SPB AB-B6SPB AB-B8SPB AB-C3SPB AB-D3SPB AB-D4SPB AB-D5SPB AB-E5SPB AB-E6SPB Enclosure Size (AxBxC) Holes Hole Arrangement Weight "F" "G" 3 1/2x3 1/4x4 7/8 3 1/2x5 1/2x4 7/8 3 1/2x7 3/4x4 7/8 3 1/2x10x4 7/8 7 1/4x6 1/4x6 3/4 7 1/4x8 1/2x6 3/4 7 1/4x10 3/4x6 3/4 7 1/4x13x6 3/4 7 1/4x15 1/4x6 3/4 7 1/4x19 3/4x6 3/4 9 1/2x8 1/2x7 7/8 11 3/4x8 1/2x9 11 3/4x10 3/4x9 11 3/4x13x9 14x13x10 1/8 14x15 1/4x10 1/8 1 2 3 4 4 6 8 10 12 16 9 12 16 20 25 30 A-1 A-2 A-3 A-4 B-2 B-3 B-4 B-5 B-6 B-8 C-3 D-3 D-4 D-5 E-5 E-6 2 3 4 5 6 7 9 10 11 12 9 11 13 14 17 19 1 3/4 1 3/4 1 3/4 1 3/4 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 1 5/8 1 5/8 1 5/8 1 5/8 2 2 2 2 2 2 2 2 2 2 2 2 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Pushbutton Enclosures & Consolets AUSTIN SLOPING PUSHBUTTON ENCLOSURES 125 AUSTIN O I LT I G H T C O N S O L E T S A N D P E D E S TA L S Austin Oiltight Consolets are Underwriters Laboratories Listed and are designed to house electrical controls and instruments. The consolet can be mounted on machines, desk tops, or Austin consolet pedestals. It can also be mounted to give a control surface incline of 30º or 60º angle. They provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Continuously welded seams ground smooth. • Cover attached by captivated screws threaded into sealed wells and continuous hinge on opposite side. • Neoprene gasket attached to cover with oil resistant adhesive. Finish: Pushbutton Enclosures & Consolets Austin Oiltight Consolets are provided standard with an ANSI 61 gray polyester powder coating. Options: • Special materials. • Special finishes. INDUSTRY STANDARDS UL 50 Type 12 & 13 NEMA Type 12 & 13 (except for mounting provisions) CUL Type 12 & 13 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 A U S T I N O I LT I G H T C O N S O L E T S A N D P E D E S TA L S Austin Pedestals and Bases allow the consolets to be floor mounted. Wiring can be installed through the base, access opening in pedestal, or directly into the consolet. Construction: • Box connector fitting, a neoprene gasket on column flange, and screws are provided to attach the consolet to the pedestal. • Pedestal fabricated from 14 gauge steel. • Base fabricated from 10 gauge steel. Pushbutton Enclosures & Consolets Finish: Austin pedestals and bases are provided standard with an ANSI 61 gray polyester powder coating. Options: • Special materials. • Special finishes. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 127 AUSTIN O I LT I G H T C O N S O L E T S A N D P E D E S TA L S .312 DIA. TYP D .312 TYP E B .813 A OMIT MIDDLE HOLES FOR 4x4 Pushbutton Enclosures & Consolets PEDESTAL ACCESS PLATE 35.000 F G ACCESS OPENING 2.000 J .312 DIA. TYP H BASE 1.000 TYP 1.000 C INDUSTRY STANDARDS UL 50 Type 12 & 13 NEMA Type 12 & 13 (except for mounting provisions) CUL Type 12 & 13 C Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 A U S T I N O I LT I G H T C O N S O L E T S A N D P E D E S TA L S Y 2.50 .75 A 10-32 SCREW w/RIVNUT D 30 Y B C .56 Pushbutton Enclosures & Consolets CONTINUOUS HINGE SECTION Y-Y Oiltight Consolets Catalog Number Enclosure Size (AxBxC) AB-88PBC AB-812PBC AB-816PBC AB-820PBC 8x8x7 5/32 8x12x7 5/32 8x16x7 5/32 8x20x7 5/32 AB-1212PBC AB-1216PBC AB-1220PBC AB-1224PBC 12x12x9 5/32 12x16x9 5/32 12x20x9 5/32 12x24x9 5/32 "D" Dimension 7 7 7 7 Weight 7/16 7/16 7/16 7/16 8 10 12 14 10 7/8 10 7/8 10 7/8 10 7/8 15 18 22 26 Catalog Number Enclosure Size (AxBxC) "D" Dimension Weight AB-1616PBC AB-1620PBC AB-1624PBC AB-1630PBC AB-1636PBC 16x16x11 5/32 16x20x11 5/32 16x24x11 5/32 16x30 11 5/32 16x36x11 5/32 14 3/8 14 3/8 14 3/8 14 3/8 14 3/8 22 27 31 34 45 AB-2020PBC AB-2024PBC AB-2030PBC 20x20x13 5/32 20x24x13 5/32 20x30x13 5/32 17 7/8 17 7/8 17 7/8 34 35 51 Pedestals and Bases Catalog Number AB-44PS AB-66PS Description (AxB) 4x4 Pedestal 6x6 Pedestal "D" "E" "F" "G" "H" "J" Weight Catalog Number 5.63 7.63 5.63 7.63 4.00 6.00 3.00 4.75 8.00 8.00 6.75 6.75 18 24 AB-1818B AB-2424B Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Description (CxC) 18x18 Base 24x24 Base Weight 20 47 Phone: 336.468.2851 800.288.2851 129 AUSTIN SCREW COVER TROUGHS Austin screw cover troughs are Underwriters Laboratories Listed for use of indoor wiring. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • End caps spot welded in. • Single sheet steel for body. • Cover attached by screws. Finish: Austin screw cover troughs are provided standard in galvanized steel. An ANSI 61 gray polyester powder coating over CRS is available on request. .750 B Wireways & Trough Products A SECTION VIEW 12" MAX Options: ENDS SPOT WELDED IN C • Special knockouts or knockout arrangements. • Special materials. • Special finishes. • Custom trough size or construction. INDUSTRY STANDARDS UL 870 NEMA Type 1 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN SCREW COVER TROUGHS Catalog Number Trough Size (AxBxC) Weight AB-4412ST AB-4424ST AB-4436ST AB-4448ST AB-4460ST AB-4472ST AB-4484ST AB-4496ST 4x4x12 4x4x24 4x4x36 4x4x48 4x4x60 4x4x72 4x4x84 4x4x96 4 8 11 15 18 22 25 29 AB-6612ST AB-6624ST AB-6636ST AB-6648ST AB-6660ST AB-6672ST AB-6684ST AB-6696ST 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x72 6x6x84 6x6x96 7 12 17 22 28 33 39 44 AB-6424ST AB-6436ST AB-6448ST 6x4x24 6x4x36 6x4x48 7 14 18 AB-8624ST AB-8636ST AB-8648ST AB-8660ST AB-8672ST 8x6x24 8x6x36 8x6x48 8x6x60 8x6x72 18 25 33 41 48 Catalog Number Trough Size (AxBxC) Weight 8x8x24 8x8x36 8x8x48 8x8x60 8x8x72 8x8x84 8x8x96 17 24 31 38 45 52 59 AB-101024ST AB-101036ST AB-101048ST AB-101060ST AB-101072ST AB-101096ST AB-1010120ST 10x10x24 10x10x36 10x10x48 10x10x60 10x10x72 10x10x96 10x10x120 27 30 47 58 69 91 112 AB-121224ST AB-121236ST AB-121248ST AB-121260ST AB-121272ST AB-121296ST AB-1212120ST 12x12x24 12x12x36 12x12x48 12x12x60 12x12x72 12x12x96 12x12x120 33 45 58 71 84 110 135 AB-181836ST AB-181860ST AB-181896ST AB-1818120ST 18x18x36 18x18x60 18x18x96 18x18x120 74 113 172 212 AB-8824ST AB-8836ST AB-8848ST AB-8860ST AB-8872ST AB-8884ST AB-8896ST Wireways & Trough Products Replace "ST" Suffix with: STG: Screw Cover Trough Gray Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 131 AUSTIN HINGE COVER TROUGHS Austin hinge cover troughs are Underwriters Laboratories Listed for use of indoor wiring. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • End caps spot welded in. • Single sheet steel for body. • Cover attached to trough with butt hinges one side and screws on opposite side. Finish: Wireways & Trough Products Austin hinge cover troughs are provided standard in galvanized steel. An ANSI 61 gray polyester powder coating over CRS is available on request. BUTT HINGE B A SECTION VIEW Options: ENDS SPOT WELDED IN C • Special knockouts or knockout arrangements. • Special materials. • Special finishes. • Custom trough size or construction. INDUSTRY STANDARDS UL 870 NEMA Type 1 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Trough Size (AxBxC) Weight AB-4412HT AB-4424HT AB-4436HT AB-4448HT AB-4460HT AB-4472HT AB-4484HT AB-4496HT 4x4x12 4x4x24 4x4x36 4x4x48 4x4x60 4x4x72 4x4x84 4x4x96 4 8 11 15 18 22 25 29 AB-6612HT AB-6624HT AB-6636HT AB-6648HT AB-6660HT AB-6672HT AB-6684HT AB-6696HT 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x72 6x6x84 6x6x96 7 12 17 22 28 33 39 44 AB-6424HT AB-6436HT AB-6448HT 6x4x24 6x4x36 6x4x48 7 14 18 AB-8624HT AB-8636HT AB-8648HT AB-8660HT AB-8672HT 8x6x24 8x6x36 8x6x48 8x6x60 8x6x72 18 25 33 41 48 AB-8824HT 8x8x24 17 Catalog Number Trough Size (AxBxC) Weight 8x8x36 8x8x48 8x8x60 8x8x72 8x8x84 8x8x96 24 31 38 45 52 59 AB-101024HT AB-101036HT AB-101048HT AB-101060HT AB-101072HT AB-101096HT AB-1010118HT 10x10x24 10x10x36 10x10x48 10x10x60 10x10x72 10x10x96 10x10x118 27 30 47 58 69 91 112 AB-121224HT AB-121236HT AB-121248HT AB-121260HT AB-121272HT AB-121296HT AB-1212118HT 12x12x24 12x12x36 12x12x48 12x12x60 12x12x72 12x12x96 12x12x118 33 45 58 71 84 110 135 AB-181836HT AB-181860HT AB-181896HT AB-1818118HT 18x18x36 18x18x60 18x18x96 18x18x118 74 113 172 212 AB-8836HT AB-8848HT AB-8860HT AB-8872HT AB-8884HT AB-8896HT Replace "HT" Suffix with: HTG: Hinge Cover Trough Gray Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Wireways & Trough Products AUSTIN HINGE COVER TROUGHS 133 AUSTIN SCREW COVER GASKETED TROUGHS Austin gasketed screw cover troughs are Underwriters Laboratories Listed and are designed to protect from rain, sleet, or snow in outdoor use. Indoor use, gasketed troughs protect from dust and moisture. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Continuously welded seams ground smooth. • Neoprene gasket attached to cover with oil resistant adhesive. Finish: Austin gasketed screw cover troughs are constructed standard in galvanized steel. An ANSI 61 gray polyester powder coating over phosphatized surfaces is available on request. GASKET Wireways & Trough Products .75 B A SEAMS WELDED SOLID AND GROUND SMOOTH SECTION VIEW Options: 6" MAX • Special materials. • Special finishes. C • Custom trough size or construction. INDUSTRY STANDARDS UL 870 NEMA Type 3 & 12 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN SCREW COVER GASKETED TROUGHS Catalog Number Trough Size (AxBxC) Weight AB-4412GST AB-4424GST AB-4436GST AB-4448GST AB-4460GST AB-4472GST AB-4484GST AB-4496GST 4x4x12 4x4x24 4x4x36 4x4x48 4x4x60 4x4x72 4x4x84 4x4x96 4 8 11 15 18 22 25 29 AB-6612GST AB-6624GST AB-6636GST AB-6648GST AB-6660GST AB-6672GST AB-6684GST AB-6696GST AB-66120GST 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x72 6x6x84 6x6x96 6x6x120 7 12 17 22 28 33 39 44 54 AB-8824GST AB-8836GST AB-8848GST AB-8860GST AB-8872GST 8x8x24 8x8x36 8x8x48 8x8x60 8x8x72 17 24 31 38 45 Catalog Number Trough Size (AxBxC) Weight 8x8x84 8x8x96 8x8x120 52 59 73 AB-101024GST AB-101036GST AB-101048GST AB-101060GST AB-101072GST AB-101096GST AB-1010120GST 10x10x24 10x10x36 10x10x48 10x10x60 10x10x72 10x10x96 10x10x120 27 30 47 58 69 91 112 AB-121224GST AB-121236GST AB-121248GST AB-121260GST AB-121272GST AB-121296GST AB-1212120GST 12x12x24 12x12x36 12x12x48 12x12x60 12x12x72 12x12x96 12x12x120 33 45 58 71 84 110 135 AB-181836GST AB-181860GST AB-181896GST AB-1818120GST 18x18x36 18x18x60 18x18x96 18x18x120 74 113 172 212 AB-8884GST AB-8896GST AB-88120GST Wireways & Trough Products Replace "GST" Suffix with: GSTG: Gasketed Screw Cover Trough Gray Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 135 AUSTIN RAINPROOF TROUGHS Austin rainproof troughs are Underwriters Laboratories Listed and are designed to provide a degree of protection against rain, sleet, and snow in outdoor use. Indoor use, rainproof troughs protect from dripping water. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Dripshield along top of trough. • Slip-on cover attached by screws at bottom edge. • Embossed mounting holes on back. Finish: Austin rainproof troughs are provided standard in galvanized. An ANSI 61 gray polyester powder coating over phosphatized |surfaces is available on request. FRONT COVER SLIDES UNDER TOP FLANGE Wireways & Trough Products TOP SECTION THRU SIDE FRONT COVER SECTION THRU TOP Options: • Special knockouts or knockout arrangements in bottom only. C A • Special materials. B • Special finishes. • Custom trough size or construction. INDUSTRY STANDARDS UL 870 NEMA Type 3R CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN RAINPROOF TROUGHS Catalog Number Trough Size (AxBxC) Weight AB-4412RT AB-4418RT AB-4424RT AB-4436RT AB-4448RT AB-4460RT AB-4472RT AB-4484RT AB-4496RT AB-44118RT 4x4x12 4x4x18 4x4x24 4x4x36 4x4x48 4x4x60 4x4x72 4x4x84 4x4x96 4x4x118 4 6 8 11 15 18 22 25 29 35 AB-6612RT AB-6624RT AB-6636RT AB-6648RT AB-6660RT AB-6672RT AB-6684RT AB-6696RT AB-66118RT 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x72 6x6x84 6x6x96 6x6x118 7 12 17 23 28 33 39 44 54 AB-8824RT AB-8836RT AB-8848RT 8x8x24 8x8x36 8x8x48 17 24 31 Catalog Number Trough Size (AxBxC) Weight 8x8x60 8x8x72 8x8x84 8x8x96 8x8x118 38 45 52 59 72 AB-101024RT AB-101036RT AB-101048RT AB-101060RT AB-101072RT AB-101084RT AB-101096RT AB-1010118RT 10x10x24 10x10x36 10x10x48 10x10x60 10x10x72 10x10x84 10x10x96 10x10x118 22 34 44 54 63 73 83 101 AB-121224RT AB-121236RT AB-121248RT AB-121260RT AB-121272RT AB-121284RT AB-121296RT AB-1212118RT 12x12x24 12x12x36 12x12x48 12x12x60 12x12x72 12x12x84 12x12x96 12x12x118 30 46 59 72 86 98 112 136 AB-8860RT AB-8872RT AB-8884RT AB-8896RT AB-88118RT Wireways & Trough Products NOTE: Replace "RT" Suffix with: RTG: Rainproof Trough Gray Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 137 JIC O I LT I G H T S C R E W C O V E R T R O U G H S Austin JIC screw cover troughs are Underwriters Laboratories Listed and are designed to provide a degree of protection against dust, dirt, oil, and water. Construction: • Cover and body fabricated from 14 gauge steel. • Neoprene gasket attached to cover with oil resistant adhesive. • Continuously welded seams ground smooth. • External mounting feet. • Cover held in place by captivated screws threaded into sealed wells. Finish: Austin JIC screw cover troughs are provided standard with an ANSI 61 gray polyester powder coating. GASKET Wireways & Trough Products B A SECTION VIEW SEAMS WELDED SOLID GROUND SMOOTH CAPTIVATED SCREWS w/SEALED WELLS. QUANTITY & LOCATION VARY w/LENGTH Options: • Special materials. • Special finishes. C INDUSTRY STANDARDS UL 870 NEMA Type 12 CUL 870 • Custom trough size or construction. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 J I C O I LT I G H T S C R E W C O V E R T R O U G H S Trough Size (AxBxC) Weight AB-4412JTS AB-4424JTS AB-4436JTS AB-4448JTS 4x4x12 4x4x24 4x4x36 4x4x48 6 10 16 20 AB-6612JTS AB-6624JTS AB-6636JTS AB-6648JTS AB-6660JTS AB-6672JTS 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x72 9 16 23 29 32 43 AB-8824JTS AB-8836JTS AB-8848JTS 8x8x24 8x8x36 8x8x48 AB-8860JTS 8x8x60 Catalog Number Trough Size (AxBxC) Weight 8x8x72 58 AB-101024JTS AB-101036JTS AB-101048JTS AB-101060JTS AB-101072JTS AB-101096JTS 10x10x24 10x10x36 10x10x48 10x10x60 10x10x72 10x10x96 27 38 48 59 70 92 23 32 40 AB-121224JTS AB-121236JTS AB-121248JTS AB-121260JTS AB-121272JTS 12x12x24 12x12x36 12x12x48 12x12x60 12x12x72 34 49 60 73 86 49 AB-121296JTS 12x12x96 99 AB-8872JTS Wireways & Trough Products Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 139 JIC O I LT I G H T H I N G E C O V E R T R O U G H S Austin JIC oiltight hinge cover troughs are Underwriters Laboratories Listed and are designed to provide a degree of protection against dust, dirt, oil, and water. Construction: • Cover and body fabricated from 14 gauge steel. • Cover held in place by external quick release clamps on one side and butt hinges on opposite side. • Neoprene gasket attached to cover with oil resistant adhesive. • External mounting feet. • Continuously welded ends and seams ground smooth. Finish: Austin JIC oiltight troughs are provided standard with an ANSI 61 gray polyester powder coating. QUICK RELEASE LATCH GASKET Wireways & Trough Products BUTT HINGE B SEAMS WELDED SOLID GROUND SMOOTH A SECTION VIEW Options: • Special materials. CLAMP/FEET QUANTITY & LOCATION VARY WITH SIZE • Special finishes. C • Custom trough size or construction INDUSTRY STANDARDS UL 870 NEMA Type 12 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 J I C O I LT I G H T H I N G E C O V E R T R O U G H S Trough Size (AxBxC) Weight AB-2212JTR AB-2218JTR AB-2224JTR AB-2230JTR AB-2236JTR AB-2248JTR AB-2260JTR AB-2272JTR 2 1/2x2 1/2x12 2 1/2x2 1/2x18 2 1/2x2 1/2x24 2 1/2x2 1/2x30 2 1/2x2 1/2x36 2 1/2x2 1/2x48 2 1/2x2 1/2x60 2 1/2x2 1/2x72 3 5 6 9 10 13 16 19 AB-4412JTR AB-4418JTR AB-4424JTR AB-4430JTR AB-4436JTR AB-4448JTR AB-4460JTR AB-4472JTR 4x4x12 4x4x18 4x4x24 4x4x30 4x4x36 4x4x48 4x4x60 4x4x72 6 8 10 13 16 20 25 30 AB-6612JTR 6x6x12 9 Catalog Number Trough Size (AxBxC) Weight AB-6618JTR AB-6624JTR AB-6630JTR AB-6636JTR AB-6648JTR AB-6660JTR AB-6672JTR 6x6x18 6x6x24 6x6x30 6x6x36 6x6x48 6x6x60 6x6x72 12 16 19 23 29 32 43 AB-8812JTR AB-8824JTR AB-8836JTR AB-8848JTR AB-8860JTR 8x8x12 8x8x24 8x8x36 8x8x48 8x8x60 13 23 32 40 49 12x12x24 12x12x36 12x12x48 12x12x60 34 49 60 73 AB-121224JTR AB-121236JTR AB-121248JTR AB-121260JTR Wireways & Trough Products Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 141 NEMA 1 S C R E W C O V E R W I R E WAY S Austin NEMA 1 screw cover wireway is Underwriters Laboratories Listed and is designed for use in housing electrical wiring. It provides a degree of protection against limited amounts of falling dirt. Fittings can be opened on any side to permit the laying in of entire runs of wiring. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Wireway is furnished with or without knockouts. • Cover has keyhole slots to permit easy removal without removing screws. • Single sheet steel for body. Finish: SCREW QUANTITY & LOCATION VARY WITH LENGTH Wireways & Trough Products Austin NEMA 1 screw cover wireway is provided standard in galvanized steel. An ANSI 61 gray polyester powder coating over CRS is available on request. C WIREWAY CONSTRUCTED TO INSIDE DIMENSIONS QUANTITY OF CONNECTOR HOLES VARY WITH SIZE B Options: A END VIEW • Special knockouts or knockout arrangements. KNOCKOUT PATTERN FOR 2.5 x 2.5 1/2"-3/4" COMBINATION • Special materials. 4.00 • Special finishes. KNOCKOUT PATTERN FOR 4 x 4 & 6 x 6 1/2"-3/4" & 1"-1 1/4" COMBINATION 4.00 4.00 INDUSTRY STANDARDS UL 870 NEMA Type 1 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Wireway Size (AxBxC) Description Weight AB-2212SW AB-2224SW AB-2236SW AB-2248SW AB-2260SW AB-2272SW AB-2284SW AB-2296SW AB-22120SW 2 1/2x2 1/2x12 2 1/2x2 1/2x24 2 1/2x2 1/2x36 2 1/2x2 1/2x48 2 1/2x2 1/2x60 2 1/2x2 1/2x72 2 1/2x2 1/2x84 2 1/2x2 1/2x96 2 1/2x2 1/2x120 2 4 6 8 10 13 16 18 20 AB-4412SW AB-4424SW AB-4436SW AB-4448SW AB-4460SW AB-4472SW AB-4484SW AB-4496SW AB-44120SW 4x4x12 4x4x24 4x4x36 4x4x48 4x4x60 4x4x72 4x4x84 4x4x96 4x4x120 AB-22EP AB-22TE AB-22L90 AB-22UC AB-22PA AB-22L45 AB-22UH AB-22X AB-22TS AB-44EP AB-44TE AB-44L90 AB-44UC AB-44PA AB-44L45 AB-44UH AB-44X AB-42R AB-44TS Catalog Number Wireway Size (AxBxC) Description Weight AB-6612SW AB-6624SW AB-6636SW AB-6648SW AB-6660SW AB-6672SW AB-6684SW AB-6696SW AB-66120SW 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x72 6x6x84 6x6x96 6x6x120 5 10 15 20 25 30 39 44 50 3 7 10 14 17 20 25 29 35 AB-8812SW AB-8824SW AB-8836SW AB-8848SW AB-8860SW AB-8872SW AB-8884SW AB-8896SW AB-88120SW 8x8x12 8x8x24 8x8x36 8x8x48 8x8x60 8x8x72 8x8x84 8x8x96 8x8x120 End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Telescope .3 2 2 .3 .5 2 2 4 3 AB-66EP AB-66TE AB-66L90 AB-66UC AB-66PA AB-66L45 AB-66UH AB-66X AB-64R AB-66TS End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope .5 5 5 .3 1 4 2 6 .5 5 AB-88EP AB-88TE AB-88L90 AB-88UC AB-88PA AB-88L45 AB-88UH AB-88X AB-86R AB-88TS Catalog Number Wireway Size (AxBxC) Description Weight AB-101012SW AB-101024SW AB-101036SW AB-101048SW AB-101060SW AB-101072SW AB-101084SW AB-101096SW AB-1010120SW 10x10x12 10x10x24 10x10x36 10x10x48 10x10x60 10x10x72 10x10x84 10x10x96 10x10x120 10 20 30 40 50 60 70 80 100 7 16 25 33 41 50 64 73 88 AB-121212SW AB-121224SW AB-121236SW AB-121248SW AB-121260SW AB-121272SW AB-121284SW AB-121296SW AB-1212120SW 12x12x12 12x12x24 12x12x36 12x12x48 12x12x60 12x12x72 12x12x84 12x12x96 12x12x120 13 26 38 51 63 75 99 112 126 End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope 1 8 7 .5 2 5 2 10 2 9 AB-1010EP AB-1010TE AB-1010L90 AB-1010UC AB-1010PA AB-1010L45 AB-1010UH AB-1010X AB-108R AB-1010TS End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope 2.5 20 18 2 3 14 5 20 2 12 End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope 2 14 12 1 2 10 3 16 2 10 AB-1212EP AB-1212TE AB-1212L90 AB-1212UC AB-1212PA AB-1212L45 AB-1212UH AB-1212X AB-1210R AB-1212TS End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope 3 26 24 2 3 19 6 24 2 15 Replace "SW" Suffix with: SWG: Screw Cover Wireway Gray SWGK: Screw Cover Wireway Gray w/KO's SWK: Screw Cover Wireway w/KO's Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Wireways & Trough Products N E M A 1 S C R E W C O V E R W I R E WAYS 143 NEMA 1 H I N G E C O V E R W I R E WAY S Austin NEMA 1 hinge cover wireway is Underwriters Laboratories Listed and is designed for use in housing electrical wiring. It provides a degree of protection against limited amounts of falling dirt. Fittings can be opened on any side to permit the laying in of entire runs of wiring. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Wireway sizes 2.5x2.5, 4x4, and 6x6 have formed hinges. • Single sheet steel for body. • Wireway can be furnished with or without knockouts. • Wireway sizes 8x8, 10x10, and 12x12 have butt hinges. • Cover is held in place by screws on opposite side of hinge. Finish: Austin NEMA 1 hinge cover wireway is provided standard in galvanized steel. An ANSI 61 gray polyester powder coating over CRS is available on request. SCREW QUANTITY & LOCATION VARY WITH LENGTH Wireways & Trough Products C - WIREWAY CONSTRUCTED TO INSIDE DIMENSIONS HINGE A QUANTITY OF CONNECTOR HOLES VARY WITH SIZE B END VIEW Options: • Special knockouts or knockout arrangements. KNOCKOUT PATTERN FOR 2.5 x 2.5 1/2"-3/4" COMBINATION • Special materials. 4.00 • Special finishes. KNOCKOUT PATTERN FOR 4 x 4 & 6 x 6 1/2"-3/4" & 1"-1 1/4" COMBINATION 4.00 4.00 INDUSTRY STANDARDS UL 870 NEMA Type 1 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Wireway Size (AxBxC) Description Weight AB-2212HW AB-2224HW AB-2236HW AB-2248HW AB-2260HW AB-2272HW AB-2284HW AB-2296HW AB-22120HW 2 1/2x2 1/2x12 2 1/2x2 1/2x24 2 1/2x2 1/2x36 2 1/2x2 1/2x48 2 1/2x2 1/2x60 2 1/2x2 1/2x72 2 1/2x2 1/2x84 2 1/2x2 1/2x96 2 1/2x2 1/2x120 2 4 6 8 10 13 16 18 20 AB-4412HW AB-4424HW AB-4436HW AB-4448HW AB-4460HW AB-4472HW AB-4484HW AB-4496HW AB-44120HW 4x4x12 4x4x24 4x4x36 4x4x48 4x4x60 4x4x72 4x4x84 4x4x96 4x4x120 AB-22EP AB-22TE AB-22L90 AB-22UC AB-22PA AB-22L45 AB-22UH AB-22X AB-22TS AB-44EP AB-44TE AB-44L90 AB-44UC AB-44PA AB-44L45 AB-44UH AB-44X AB-42R AB-44TS Catalog Number Wireway Size (AxBxC) Description Weight AB-6612HW AB-6624HW AB-6636HW AB-6648HW AB-6660HW AB-6672HW AB-6684HW AB-6696HW AB-66120HW 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x72 6x6x84 6x6x96 6x6x120 5 10 15 20 25 30 39 44 50 3 7 10 14 17 20 25 29 35 AB-8812HW AB-8824HW AB-8836HW AB-8848HW AB-8860HW AB-8872HW AB-8884HW AB-8896HW AB-88120HW 8x8x12 8x8x24 8x8x36 8x8x48 8x8x60 8x8x72 8x8x84 8x8x96 8x8x120 End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Telescope .3 2 2 .3 .5 2 2 4 3 AB-66EP AB-66TE AB-66L90 AB-66UC AB-66PA AB-66L45 AB-66UH AB-66X AB-64R AB-66TS End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope .5 5 5 .3 1 4 2 6 .5 5 AB-88EP AB-88TE AB-88L90 AB-88UC AB-88PA AB-88L45 AB-88UH AB-88X AB-86R AB-88TS Catalog Number Wireway Size (AxBxC) Description Weight AB-101012HW AB-101024HW AB-101036HW AB-101048HW AB-101060HW AB-101072HW AB-101084HW AB-101096HW AB-1010120HW 10x10x12 10x10x24 10x10x36 10x10x48 10x10x60 10x10x72 10x10x84 10x10x96 10x10x120 10 20 30 40 50 60 70 80 100 7 16 25 33 41 50 64 73 88 AB-121212HW AB-121224HW AB-121236HW AB-121248HW AB-121260HW AB-121272HW AB-121284HW AB-121296HW AB-1212120HW 12x12x12 12x12x24 12x12x36 12x12x48 12x12x60 12x12x72 12x12x84 12x12x96 12x12x120 13 26 38 51 63 75 99 112 126 End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope 1 8 7 .5 2 5 2 10 2 9 AB-1010EP AB-1010TE AB-1010L90 AB-1010UC AB-1010PA AB-1010L45 AB-1010UH AB-1010X AB-108R AB-1010TS End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope 2.5 20 18 2 3 14 5 20 2 12 End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope 2 14 12 1 2 10 3 16 2 10 AB-1212EP AB-1212TE AB-1212L90 AB-1212UC AB-1212PA AB-1212L45 AB-1212UH AB-1212X AB-1210R AB-1212TS End Cap Tee 90 Elbow U-Connector Panel Adapter 45 Elbow U-Hanger Cross Reducer Telescope 3 26 24 2 3 19 6 24 2 15 Replace "HW" Suffix with: HWG: Hinge Cover Wireway Gray HWGK: Hinge Cover Wireway Gray w/KO's HWK: Hinge Cover Wireway w/KO's Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Wireways & Trough Products N E M A 1 H I N G E C O V E R W I R E WAYS 145 NEMA 1 W I R E WAY F I T T I N G S C E B A TEE Allows runs of wireway to split off or come together at a 90˚ angle E Wireways & Trough Products B A CROSS B 6.00 Allows runs of wireway to intersect and cross or split off at 90˚ angles A 0 - 5.00 TELESCOPE Length easily adjusts from 6" to 11". No cutting or welding is required D C C B B A A 90˚ ELBOW 45˚ ELBOW Similar to the 90˚ elbow but only makes a 45˚ turn Any side can be removed to retain the lay-in feature of the wireway. Sides are held in place with screws Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 N E M A 1 W I R E WAY F I T T I N G S Wireway Size A B C D E F G 2 1/2x2 1/2 4x4 6x6 8x8 10x10 12x12 2 1/2 4 6 8 10 12 2 1/2 4 6 8 10 12 5 8 12 14 16 18 3 4 5/8 5 7/16 6 1/4 7 1/8 7 15/16 7 1/2 12 18 20 22 24 NA 2 1/2 4 6 8 10 NA 2 1/2 4 6 8 10 B A U-CONNECTOR PANEL ADAPTER U-Connectors are used to join sections of wireway together. These must be ordered separately. Allows a run of wireway to be securely connected to an enclosure A A B G UNIVERSAL HANGER Allows runs of wireway to be supported from either the ceiling or the wall F REDUCER Allows the reduction of a run of wireway to a smaller wireway size END CAP Used to close off the end of a wireway run Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Wireways & Trough Products B 147 JIC P U L L -T H R O U G H W I R E WAY Austin JIC Pull-Through wireway is Underwriters Laboratories Listed and is designed to protect electrical wiring from dust, dirt, oil, and water. Construction: • Fabricated in accordance with UL specifications from 14 gauge steel. • Cover attached to body with heavy butt hinges and quick release clamps. • Continuously welded seams. • One piece oil-resistant gasket is provided with each straight section and fitting for bolting sections together. • Neoprene gasket attached to cover with oil-resistant adhesive. Finish: Wireways & Trough Products Austin JIC PullThrough wireway is provided standard with an ANSI 61 gray polyester powder coating inside and out. CONNECTING HOLES VARY WITH SIZE C B LATCH QUANTITY & LOCATION VARY WITH SIZE A Options: QUICK RELEASE LATCH GASKET BUTT HINGE • Special materials. • Special finishes. B A SECTION VIEW INDUSTRY STANDARDS UL 870 NEMA Type 12 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Catalog Number Wireway Size (AxBxC) Description Weight AB-2212JW AB-2224JW AB-2236JW AB-2248JW AB-2260JW AB-22120JW AB-22JL90 AB-22JL45 AB-22JTE AB-22JX AB-22JTSC NA AB-22JBF AB-22JCF AB-22JN1 AB-22JN2 AB-22JN3 AB-22JBH AB-22JDH AB-22JEP AB-22JG 2 1/2x2 1/2x12 2 1/2x2 1/2x24 2 1/2x2 1/2x36 2 1/2x2 1/2x48 2 1/2x2 1/2x60 2 1/2x2 1/2x120 90 Elbow 45 Elbow Tee Cross Telescope Reducer Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Bracket Hanger Drop Hanger End Plate Gasket 4 7 11 15 19 35 3 2 4 5 4 AB-4412JW AB-4424JW AB-4436JW AB-4448JW AB-4460JW AB-44120JW AB-44JL90 AB-44JL45 AB-44JTE AB-44JX AB-44JTSC AB-42JR AB-44JBF AB-44JCF AB-44JN1 AB-44JN2 AB-44JN3 AB-44JBH AB-44JDH AB-44JEP AB-44JG 4x4x12 4x4x24 4x4x36 4x4x48 4x4x60 4x4x120 90 Elbow 45 Elbow Tee Cross Telescope Reducer Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Bracket Hanger Drop Hanger End Plate Gasket 7 12 17 21 26 55 5 3 6 8 7 1 1 6 2 2 2 1 1 1 1 3 1 1 2 1 1 1 Catalog Number Wireway Size (AxBxC) Description Weight AB-6612JW AB-6624JW AB-6636JW AB-6648JW AB-6660JW AB-66120JW AB-66JL90 AB-66JL45 AB-66JTE AB-66JX AB-66JTSC AB-64JR AB-66JBF AB-66JCF AB-66JN1 AB-66JN2 AB-66JN3 AB-66JBH AB-66JDH AB-66JEP AB-66JG 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x120 90 Elbow 45 Elbow Tee Cross Telescope Reducer Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Bracket Hanger Drop Hanger End Plate Gasket 10 18 24 32 40 76 8 6 10 13 11 2 1 8 3 3 4 3 2 3 AB-8812JW AB-8824JW AB-8836JW AB-8848JW AB-8860JW AB-88120JW AB-88JL90 AB-88JL45 AB-88JTE AB-88JX AB-88JTSC AB-86JR AB-88JBF AB-88JCF AB-88JN1 AB-88JN2 AB-88JN3 AB-88JBH AB-88JDH AB-88JEP AB-88JG 8x8x12 8x8x24 8x8x36 8x8x48 8x8x60 8x8x120 90 Elbow 45 Elbow Tee Cross Telescope Reducer Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Bracket Hanger Drop Hanger End Plate Gasket 12 21 32 42 51 99 12 9 15 18 15 3 2 11 4 4 5 6 6 4 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Wireways & Trough Products J I C P U L L -T H R O U G H W I R E WAY Phone: 336.468.2851 800.288.2851 149 JIC P U L L -T H R O U G H W I R E WAY F I T T I N G S C B A 90˚ ELBOW Allows a wireway run to turn at a 90˚ angle D D Wireways & Trough Products B A CROSS Allows runs of wireway to intersect and cross or split off at 90˚ angles B B 13.50 A 12.00 A TELESCOPE Allows easy adjustment for up to 12" CUT-OFF FITTING E Allows user to cut off part of fitting and weld on flange to form a section between 1" and 12" D B B A A C 45˚ ELBOW Similar to a 90˚ elbow but only makes a 45˚ turn TEE Allows runs of wireway to split off or come together at a 90˚ angle Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 J I C P U L L -T H R O U G H W I R E WAY F I T T I N G S Wireway Size A B C D E F G K M R S T 2 1/2x2 1/2 4x4 6x6 8x8 2 1/2 4 6 8 2 1/2 4 6 8 6 1/2 8 10 12 10 1/2 12 14 16 3 3/8 4 4 7/8 5 5/8 NA 2 1/2 4, 2 1/2 6,4,2 1/2 NA 2 1/2 4, 2 1/2 6,4,2 1/2 11 3/4 13 1/4 15 1/4 19 1/4 4 5/8 6 1/8 8 1/8 10 1/8 4 5 1/2 7 1/2 9 1/2 4 5 1/2 5 1/2 5 1/2 4 1/2 6 8 10 M B B R A A S T L K NIPPLE END PLATE Available in 1", 2", and 3" lengths Used to close off the end of a wireway run BRACKET HANGER Allows a run of wireway to be attached to the wall, ceiling, or floor A B B B A F GASKET BOX FITTING Used when wireway enters an enclosure on the inside of the enclosure to provide a tight seal Neoprene gasket used to provide a water tight seal between sections of wireway or between sections of wireway and fittings REDUCER Allows reduction of a wireway run to a smaller wireway size Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Wireways & Trough Products DROP HANGER Allows a run of wireway to be suspended from the ceiling G A 151 JIC P U L L -T H R O U G H W I R E WAY N E M A 4 X Austin JIC Pull-Through NEMA 4X wireway is Underwriters Laboratories Listed and is designed to protect electrical wiring from dust, dirt, oil, and water. Construction: • Fabricated in accordance with UL specifications from 14 gauge Type 304 stainless steel. • Cover attached to body with heavy butt hinges and quick release clamps. • Continuously welded seams. • One piece oil-resistant gasket is provided with each straight section and fitting for bolting sections together. • Neoprene gasket attached to cover with oil-resistant adhesive. Finish: Austin JIC Pull-Through 4X wireway is provided standard in Type 304 stainless steel. SCREW CLAMP GASKET BUTT HINGE Wireways & Trough Products B A SECTION VIEW CONNECTING HOLES VARY WITH SIZE LATCH QUANTITY & LOCATION VARY WITH SIZE Options: • Type 316 stainless steel C B A INDUSTRY STANDARDS UL 870 NEMA Type 4, 4X & 12 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 J I C P U L L -T H R O U G H W I R E WAY N E M A 4 X AB-4412JWFX AB-4424JWFX AB-4436JWFX AB-4448JWFX AB-4460JWFX AB-44120JWFX AB-44JL90X AB-44JL45X AB-44JTEX AB-44JXX AB-44JTSX AB-42JRX AB-44JBFX AB-44JCFX AB-44JN1X AB-44JN2X AB-44JN3X AB-44JBHX AB-44JDHX AB-44JEPX AB-44JG Wireway Size (AxBxC) Description Weight 4x4x12 4x4x24 4x4x36 4x4x48 4x4x60 4x4x120 90 Elbow 45 Elbow Tee Cross Telescope Reducer Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Bracket Hanger Drop Hanger End Plate Gasket 7 12 17 21 26 55 5 3 6 8 7 1 1 6 2 2 2 1 1 1 Catalog Number AB-6612JWFX AB-6624JWFX AB-6636JWFX AB-6648JWFX AB-6660JWFX AB-66120JWFX AB-66JL90X AB-66JL45X AB-66JTEX AB-66JXX AB-66JTSX AB-64JRX AB-66JBFX AB-66JCFX AB-66JN1X AB-66JN2X AB-66JN3X AB-66JBHX AB-66JDHX AB-66JEPX AB-66JG Wireway Size (AxBxC) Description Weight 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x120 90 Elbow 45 Elbow Tee Cross Telescope Reducer Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Bracket Hanger Drop Hanger End Plate Gasket 10 18 24 32 40 76 8 6 10 13 11 2 1 8 3 3 4 3 2 3 Wireways & Trough Products Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 153 JIC L AY- I N W I R E WAY Austin JIC Lay-In wireway is Underwriters Laboratories Listed and is designed to protect electrical wiring from dust, dirt, oil, and water. All sections and fittings are completely open on one side to allow a complete run of wiring to be laid into the wireway run. Construction: • One piece oil-resistant gasket and flat sealing plate (not shown) are provided with each straight section and fitting and a 90º sealing plate with each end plate for bolting sections together. • Fabricated in accordance with UL specifications from 14 gauge steel. • Continuously welded seams. • Neoprene gasket attached to cover with oil-resistant adhesive. • Cover attached to body with heavy butt hinges and quick release clamps. Finish: Wireways & Trough Products Austin JIC Lay-In wireway is provided standard with an ANSI 61 gray polyester powder coating inside and out. CONNECTING HOLES VARY WITH SIZE C LATCH QUANTITY & LOCATION VARY WITH SIZE B Options: A QUICK RELEASE LATCH • Special materials. GASKET BUTT HINGE • Special finishes. B A SECTION VIEW INDUSTRY STANDARDS UL 870 NEMA Type 12 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 J I C L AY- I N W I R E WAY Wireway Size (AxBxC) Description Catalog Number Wireway Size (AxBxC) Description Catalog Number Wireway Size (AxBxC) Description Catalog Number Wireway Size (AxBxC) Description AB-2212LW AB-2224LW AB-2236LW AB-2248LW AB-2260LW AB-22120LW 2 1/2x2 1/2x12 2 1/2x2 1/2x24 2 1/2x2 1/2x36 2 1/2x2 1/2x48 2 1/2x2 1/2x60 2 1/2x2 1/2x120 AB-4412LW AB-4424LW AB-4436LW AB-4448LW AB-4460LW AB-44120LW 4x4x12 4x4x24 4x4x36 4x4x48 4x4x60 4x4x120 AB-6612LW AB-6624LW AB-6636LW AB-6648LW AB-6660LW AB-66120LW 6x6x12 6x6x24 6x6x36 6x6x48 6x6x60 6x6x120 AB-8812LW AB-8824LW AB-8836LW AB-8848LW AB-8860LW AB-88120LW 8x8x12 8x8x24 8x8x36 8x8x48 8x8x60 8x8x120 AB-22LL90T AB-22LL90N AB-22LL90 AB-22LL45T AB-22LL45N AB-22LL45 AB-22LTT AB-22LT AB-22LX AB-22LL90R 90L Outside open 90L Inside open 90L Top Open 45L Outside open 45L Inside open 45L Top Open Tee Top open Tee Outside open Cross Clockwise Transposition 90L Counter Clockwise Transposition 90L Straight Clockwise Transposition Straight Counter Clockwise Transposition Junction Box Telescope Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Reducer Bracket Hanger Drop Hanger End Plate Flat Sealing Plate 90 Sealing Plate AB-44LL90T AB-44LL90N AB-44LL90 AB-44LL45T AB-44LL45N AB-44LL45 AB-44LTT AB-44LT AB-44LX AB-44LL90R 90L Outside open 90L Inside open 90L Top Open 45L Outside open 45L Inside open 45L Top Open Tee Top open Tee Outside open Cross Clockwise Transposition 90L Counter Clockwise Transposition 90L Straight Clockwise Transposition Straight Counter Clockwise Transposition Junction Box Telescope Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Reducer Bracket Hanger Drop Hanger End Plate Flat Sealing Plate 90 Sealing Plate AB-66LL90T AB-66LL90N AB-66LL90 AB-66LL45T AB-66LL45N AB-66LL45 AB-66LTT AB-66LT AB-66LX AB-66LL90R 90L Outside open 90L Inside open 90L Top Open 45L Outside open 45L Inside open 45L Top Open Tee Top open Tee Outside open Cross Clockwise Transposition 90L Counter Clockwise Transposition 90L Straight Clockwise Transposition Straight Counter Clockwise Transposition Junction Box Telescope Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Reducer Bracket Hanger Drop Hanger End Plate Flat Sealing Plate 90 Sealing Plate AB-88LL90T AB-88LL90N AB-88LL90 AB-88LL45T AB-88LL45N AB-88LL45 AB-88LTT AB-88LT AB-88LX AB-88LL90R 90L Outside open 90L Inside open 90 Elbow 45L Outside open 45L Inside open 45 Elbow Tee Top open Tee Outside open Cross Clockwise Transposition 90L Counter Clockwise Transposition 90L Straight Clockwise Transposition Straight Counter Clockwise Transposition Junction Box Telescope Box Fitting Cut-off Fitting Nipple 1" Nipple 2" Nipple 3" Reducer Bracket Hanger Drop Hanger End Plate Flat Sealing Plate 90 Sealing Plate AB-22LL90L AB-22LCS AB-22LCC AB-22LJB AB-22LTS AB-22LBF AB-22LCF AB-22LN1 AB-22LN2 AB-22LN3 NA AB-22LBH AB-22LDH AB-22LEP AB-22LFP AB-22LNP AB-44LL90L AB-44LCS AB-44LCC AB-44LJB AB-44LTS AB-44LBF AB-44LCF AB-44LN1 AB-44LN2 AB-44LN3 AB-42LR AB-44LBH AB-44LDH AB-44LEP AB-44LFP AB-44LNP AB-66LL90L AB-66LCS AB-66LCC AB-66LJB AB-66LTS AB-66LBF AB-66LCF AB-66LN1 AB-66LN2 AB-66LN3 AB-64LR AB-66LBH AB-66LDH AB-66LEP AB-66LFP AB-66LNP AB-88LL90L AB-88LCS AB-88LCC AB-88LJB AB-88LTS AB-88LBF AB-88LCF AB-88LN1 AB-88LN2 AB-88LN3 AB-86LR AB-88LBH AB-88LDH AB-88LEP AB-88LFP AB-88LNP Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Wireways & Trough Products Catalog Number 155 JIC L AY- I N W I R E WAY F I T T I N G S D B A C TEE TOP OPENING This is used when all the wireway branches open on the same side D Wireways & Trough Products C B B A C A TEE OUTSIDE OPENING This is used when two branches open on the same side and the third opens on another side STRAIGHT TRANSPOSITION CLOCKWISE B C A STRAIGHT TRANSPOSITION COUNTER CLOCKWISE Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 J I C L AY- I N W I R E WAY F I T T I N G S C Wireways & Trough Products C B A C B A 90˚ ELBOW B A TOP OPENING 90˚ ELBOW OUTSIDE OPENING 90˚ ELBOW INSIDE OPENING E A B B B E A E 45˚ ELBOW TOP OPENING 45˚ ELBOW OUTSIDE OPENING A 45˚ ELBOW INSIDE OPENING Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 157 JIC L AY- I N W I R E WAY F I T T I N G S M K R S T BRACKET HANGER Allows a run of wireway to be attached to the wall, ceiling, or floor DROP HANGER Allows a run of wireway to be suspended from the ceiling Wireways & Trough Products B B A A REDUCER Reduces the run to a smaller wireway size without losing the lay-in feature. Furnished with special sealing plate END PLATE Used to close off the end of a wireway run B B C A A L TELESCOPE Allows easy adjustment for up to 12" NIPPLE Available in 1", 2", 3", and 6" lengths Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 J I C L AY- I N W I R E WAY F I T T I N G S Wireway Size A B C D E F G K M R S T X Y Z 2 1/2x2 1/2 4x4 6x6 8x8 2 1/2 4 6 8 2 1/2 4 6 8 6 1/2 8 10 12 10 1/2 12 14 16 3 3/8 4 4 7/8 5 5/8 NA 2 1/2 4, 2 1/2 6,4,2 1/2 NA 2 1/2 4, 2 1/2 6,4,2 1/2 11 3/4 13 1/4 15 1/4 19 1/4 4 5/8 6 1/8 8 1/8 10 1/8 4 5 1/2 7 1/2 9 1/2 4 5 1/2 5 1/2 5 1/2 4 1/2 6 8 10 10 12 14 16 10 1/2 14 18 22 12 14 16 18 C B C A A COUNTER CLOCKWISE TRANSPOSITION 90˚ ELBOW B CLOCKWISE TRANSPOSITION 90˚ ELBOW B 20.000 A CUT-OFF FITTING Y X For lengths of 8" to 20". The body comes in two pieces. Shorten body and cover to desired length and weld JUNCTION BOX B Wireways & Trough Products Z A JIC LATCH ON ALL FOUR CORNERS D D B B A A CROSS An intersection device used when all wireway opens on the same side Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 159 NEMA 1 X - RAY E Q U I P M E N T L AY- I N D U C T Austin Lay-In wireway for X-Ray equipment is Underwriters Laboratories Listed and is designed to house electrical wiring where protection from dust, dirt, oil, and water are not necessary. Construction: • Fabricated in accordance with UL specifications from code gauge steel. • Single sheet steel for body. • Cover attached to body with plated steel screws. Finish: Austin Lay-In wireway for X-Ray equipment is provided standard with an ANSI 61 gray polyester powder coating inside and out. Wireways & Trough Products SCREW QUANTITY & LOCATION VARY WITH LENGTH C B Options: • Special materials. A • Special finishes. INDUSTRY STANDARDS UL 870 NEMA Type 1 CUL 870 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 N E M A 1 X - RAY E Q U I P M E N T L AY- I N D U C T AB-1012YW AB-1024YW AB-1036YW AB-1048YW AB-1060YW AB-1072YW AB-1084YW AB-1096YW AB-10120YW Catalog Number AB-60YD AB-10YHL AB-10YVL AB-10YHT AB-10YVT AB-10YX AB-10YEC AB-10YC AB-10YPA Wireway Size (AxBxC) Weight 10x3 1/2x12 10x3 1/2x24 10x3 1/2x36 10x3 1/2x48 10x3 1/2x60 10x3 1/2x72 10x3 1/2x84 10x3 1/2x96 10x3 1/2x120 7 15 22 30 37 45 52 60 73 Description Weight 60" Divider Horizontal 90 Elbow Vertical 90 Elbow Horizontal Tee Vertical Tee Cross End Cap U-Connector Panel Adapter 5 8 7 7 7 8 1 1 2 Catalog Number AB-1812YW AB-1824YW AB-1836YW AB-1848YW AB-1860YW AB-1872YW AB-1884YW AB-1896YW AB-18120YW Catalog Number AB-60YD AB-18YHL AB-18YVL AB-18YHT AB-18YVT AB-18YX AB-18YEC AB-18YC AB-18YPA Wireway Size (AxBxC) Weight 18x3 1/2x12 18x3 1/2x24 18x3 1/2x36 18x3 1/2x48 18x3 1/2x60 18x3 1/2x72 18x3 1/2x84 18x3 1/2x96 18x3 1/2x120 12 23 35 47 58 70 81 93 117 Description Weight 60" Divider Horizontal 90 Elbow Vertical 90 Elbow Horizontal Tee Vertical Tee Cross End Cap U-Connector Panel Adapter 5 23 11 23 23 24 2 2 2 Wireways & Trough Products Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 161 NEMA 1 X - RAY D U C T E Q U I P M E N T F I T T I N G S END CAP D B A CROSS C D Wireways & Trough Products C B B A A HORIZONTAL 90˚ ELBOW HORIZONTAL TEE E F E A A B B VERTICAL 90˚ ELBOW VERTICAL TEE Wireway Size A B C D E F 10x3 1/2 18x3 1/2 10 18 3 1/2 3 1/2 12 20 14 22 6 6 8 1/2 8 1/2 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 Wireways & Trough Products N E M A 1 X - RAY D U C T E Q U I P M E N T F I T T I N G S CONNECTOR TYPICAL X-RAY DUCT RUN DIVIDER PANEL ADAPTER Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 163 JIC PANELS S T E E L , A L U M I N U M , S TA I N L E S S JIC steel panels are 14 gauge painted white. Stainless steel panels are 14 gauge Type 304. Aluminum panels are 5052-H32 aluminum alloy. Mounting hardware is furnished with all enclosures that will accept these panels. Catalog Number (Steel) AB-64JP AB-66JP AB-86JP AB-88JP AB-108JP AB-1010JP AB-126JP AB-1210JP AB-1212JP AB-1412JP AB-1614JP Panel Size (AxB) Weight 4 7/8 x 2 7/8 4 7/8 x 4 7/8 6 7/8 x 4 7/8 6 7/8 x 6 7/8 8 7/8 x 6 7/8 8 7/8 x 8 7/8 10 7/8 x 4 7/8 10 7/8 x 8 7/8 10 7/8 x 10 7/8 12 7/8 x 10 7/8 14 7/8 x 12 7/8 0.3 0.5 1 1 1.3 2 1.3 2 3 3 5 B Accessories .218 x .312 OBROUND A .31 .31 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 J I C PA N E L S S T E E L , A L U M I N U M , S TA I N L E S S AB-64JPA AB-66JPA AB-86JPA AB-108JPA AB-1210JPA AB-1412JPA AB-1614JPA Panel Size (AxB) Weight 4 7/8 x 2 7/8 4 7/8 x 4 7/8 6 7/8 x 4 7/8 8 7/8 x 6 7/8 10 7/8 x 8 7/8 12 7/8 x 10 7/8 14 7/8 x 12 7/8 0.5 0.5 0.5 1 1 1 2 Catalog Number (Stainless Steel) AB-66JPX AB-86JPX AB-88JPX AB-108JPX AB-1210JPX AB-1212JPX AB-1412JPX AB-1614JPX Panel Size (AxB) Weight 4 7/8 x 4 7/8 6 7/8 x 4 7/8 6 7/8 x 6 7/8 8 7/8 x 6 7/8 10 7/8 x 8 7/8 10 7/8 x 10 7/8 12 7/8 x 10 7/8 14 7/8 x 12 7/8 0.5 1 1 1.5 2 3 3 5 Accessories Catalog Number (Aluminum) Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 165 NEMA STEEL PANELS FOR SINGLE AND DOUBLE DOOR NEMA Panels are code gauge steel and painted white. All panels have flanges on all four sides. Stainless steel panels are Type 304 or optional 316 stainless steel. Panel mounting hardware is furnished with all enclosures that will accept these panels. B Accessories OMIT TWO MIDDLE HOLES IF PANEL WIDTH IS 27" OR UNDER A OMIT TWO MIDDLE HOLES IF PANEL HEIGHT IS 27" OR UNDER .88 .88 .750 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 NEMA STEEL PANELS FOR SINGLE AND DOUBLE DOOR Steel Panels for Single Door NEMA 4 & 12 Enclosures and Double Door Wall-Mt N-12 Enclosures AB-1612TP AB-1616TP AB-2012TP AB-2016TP AB-2020TP AB-2412TP AB-2416TP AB-2418TP AB-2420TP AB-2424TP AB-3016TP AB-3020TP AB-3024TP AB-3030TP AB-3624TP Stainless Steel Catalog Number AB-1612TPX AB-1616TPX AB-2012TPX AB-2016TPX AB-2020TPX AB-2412TPX AB-2416TPX AB-2418TPX AB-2420TPX AB-2424TPX AB-3016TPX AB-3020TPX AB-3024TPX AB-3030TPX AB-3624TPX Panel Size (AxB) Weight 13x9 13x13 17x9 17x13 17x17 21x9 21x13 23x15 21x17 21x21 27x13 27x17 27x21 27x27 33x21 4 6 5 7 9 7 9 8 13 15 12 16 19 24 24 Catalog Number AB-3630TP AB-3636TP AB-4224TP AB-4230TP AB-4236TP AB-4824TP AB-4830TP AB-4836TP AB-6030TP AB-6036TP AB-6042TP AB-7224TP AB-7230TP AB-4848TP Stainless Steel Catalog Number Panel Size (AxB) Weight AB-3630TPX AB-3636TPX AB-4224TPX AB-4230TPX AB-4236TPX AB-4824TPX AB-4830TPX AB-4836TPX AB-6030TPX AB-6036TPX AB-6042TPX AB-7224TPX AB-7230TPX AB-4848TPX 33x27 33x33 39x21 39x27 39x33 45x21 45x27 45x33 57x27 57x33 57x39 69x21 69x27 45x45 30 37 28 35 43 32 40 49 43 61 71 49 62 80 Steel Panels for Double Door NEMA 12 Enclosures with Legs Catalog Number AB-5442DP AB-6048DP AB-6060DP Panel Size (AxB) 50x38 56x44 56x56 Weight 62 103 130 Catalog Number AB-7260DP AB-7272DP Panel Size (AxB) 68x56 68x68 Weight 158 191 Steel Panels for Freestanding NEMA 12 Enclosures Catalog Number AB-7224FTP AB-7230FTP AB-7236FTP AB-9036FTP Panel Size (AxB) 60x20 60x26 60x32 78x32 Weight 65 74 98 108 Catalog Number AB-7248FTP AB-7260FTP AB-7272FTP AB-9072FTP Panel Size (AxB) 60x44 60x56 60x68 78x68 Weight 131 159 187 238 Accessories Catalog Number Steel Panels for Double Door NEMA 4 Enclosures Catalog Number AB-6248FP AB-6260FP Panel Size (AxB) 56x44 56x56 Weight 103 130 Catalog Number AB-7460FP AB-7472FP Panel Size (AxB) 68x56 68x68 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Weight 158 191 Phone: 336.468.2851 800.288.2851 167 JIC SWING-OUT PANEL KITS Designed to allow mounting of switches, gauges, pilot lights, and other components near the front of enclosure for easy access. Each kit contains heavy-gauge brackets and hinges which can be installed by drilling holes in the sides of the enclosure and bolting the brackets in place. Mounting hardware and instructions are provided. Swing-out panels can be mounted on either side. Sealing washers are furnished to ensure that the enclosures will meet the original JIC standards after they are installed. JIC box Swing-Out Panel Kit can be mounted in the following enclosures: • All JIC boxes where A x B is 8 x 6 or larger. Accessories Catalog Number AB-JSOPK Description JIC Swing-Out Panel Kit *Panels must be ordered separately. *The maximum load on JIC Panel Kit cannot exceed 25 pounds. The load includes the weight of the panel plus the weight of the added components, with the weight of the components spread evenly over the panel. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 JIC SWING-OUT PANEL KITS .38 .62 MIN. .31 1.56 1.38 1.31 .81 DETAIL "B" DETAIL "A" DETAIL "A" HINGE BRACKETS RETAINING BRACKETS ENCLOSURE (ORDER SEPARATELY) BRACKET MOUNTING SCREWS PANEL (ORDER SEPARATELY) Accessories SEALING WASHERS PANEL MOUNTING SCREWS DETAIL "B" SCREW RETAINER SPACE AVAILABLE ON SWING-OUT PANEL CAPTIVE THUMB SCREW Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 169 NEMA SWING-OUT PANEL KITS Designed to allow mounting of switches, gauges, pilot lights, and other components near the front of enclosure for easy access. Each kit contains heavy-gauge brackets and hinges which can be installed by drilling holes in the sides of the enclosure and bolting the brackets in place. Mounting hardware and instructions are provided. Swing-out panels can be mounted on either side. Sealing washers are furnished to ensure that the enclosures will meet the original NEMA standards after they are installed. NEMA Swing-Out Panel Kit can be mounted in the following enclosures: • All single door Type 4, 12, and 13 enclosures where A x B is 12 x 12 or larger. • All “WL” Type 3R enclosures where A x B is 16 x 16 or larger. • All “LM” Type 1 enclosures where A x B is 16 x 12 or larger. Accessories Catalog Number AB-NSOPK Description NEMA Swing-Out Panel Kit *Panels must be ordered separately. *The maximum load on NEMA Panel Kit cannot exceed 100 pounds. The load includes the weight of the panel plus the weight of the added components, with the weight of the components spread evenly over the panel. Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 NEMA SWING-OUT PANEL KITS 1.25 MIN. 1.88 1.12 1.09 .50 .50 2.88 2.88 DETAIL "A" DETAIL "B" DETAIL "A" HINGE BRACKET BRACKET MOUNTING SCREW ENCLOSURE (ORDER SEPARATELY) SEALING WASHER RETAINING BRACKET Accessories PANEL MOUNTING CARRIAGE BOLT PANEL (ORDER SEPARATELY) CAPTIVE THUMB SCREW SPACE AVAILABLE ON SWING-OUT PANEL DETAIL "B" SCREW RETAINER Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 171 JIC T E R M I N A L S T R A P K I T A S S E M B LY Provides a strong, versatile, and easily installed means for mounting terminal blocks in JIC boxes. These kits can be installed in all JIC boxes. Bracket Assembly: • Each bracket assembly consists of two brackets which mount on panel stand-offs in the box. Finish is white. Terminal Strap: TERMINAL STRAP • A 12 gauge flat strap that mounts on top of brackets. They can be positioned anywhere along the brackets and are held in place with spring locking nuts. Finish is white. BRACKET B X A F G 1.63 1.50 Accessories X E SECTION X-X Terminal Kit Assembly for JIC Boxes Bracket Assemblies Bracket Assembly Catalog Number AB-6JBKTA AB-8JBKTA AB-10JBKTA AB-12JBKTA AB-14JBKTA Enclosure Dimension Parallel to Brackets "E" Dimension 6 8 10 12 14 5 7 9 11 13 Terminal Strap Catalog Number AB-8JTST AB-10JTST AB-12JTST AB-14JTST AB-16JTST Enclosure Dimension Parallel to Straps "F" Dimension "G" Dimension (Useable Space) 8 10 12 14 16 5.75 7.75 9.75 11.75 13.75 4.438 6.438 8.438 10.438 12.438 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 NEMA T E R M I N A L S T R A P K I T A S S E M B LY Provides a strong, versatile, and easily installed means for mounting terminal block supports. These kits fit Type 4, 12, and 13 enclosures as well as Large Type 1 enclosures. Bracket Assembly: • Each bracket assembly consists of two or three brackets which mount on panel stand-offs in the box. Finish is white. Terminal Strap: BRACKET B • A 12 gauge flat channel strap that mounts on top of brackets. They can be positioned anywhere along the brackets and are held in place with spring locking nuts. Finish is white. X 3.187 F A E X Accessories 1.50 SECTION X-X TERMINAL STRAP D Terminal Kit Assembly for NEMA Enclosures Bracket Assemblies Bracket Assembly Catalog Number AB-12NBKTA2 AB-16NBKTA2 AB-20NBKTA2 AB-24NBKTA2 AB-24NBKTA3 AB-30NBKTA2 AB-30NBKTA3 AB-36NBKTA2 AB-36NBKTA3 Number of Brackets Enclosure Dimension Parallel to Brackets "D" Dimension 2 2 2 2 3 2 3 2 3 12 16 20 24 24 30 30 36 36 8.75 12.75 16.75 20.75 20.75 26.75 26.75 32.75 32.75 Terminal Strap Catalog Number Enclosure Dimension Parallel to Straps "F" Dimension "E" Dimension (Useable Space) 16 20 24 30 36 42 48 60 13 17 21 27 33 39 45 57 11.5 15.5 19.5 25.5 31.5 37.5 43.5 55.5 AB-16NTS AB-20NTS AB-24NTS AB-30NTS AB-36NTS AB-42NTS AB-48NTS AB-60NTS Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 173 AUSTIN L O U V E R P L AT E K I T S Austin Louver Plate Kits are designed to provide ventilation for areas where excessive moisture or internal heat is present. They are easily installed by making a cutout of the proper size and attaching the louver plate to the enclosure. All hardware is furnished for mounting. Catalog Number AB-44LK AB-58LK Louver Length Number of Louvers 4" 5" 4 8 Size of Plate 5 5/8" x 5 1/2" 7 1/4" x 10 3/4" Weight 1 1 Accessories CABINET LOUVER PLATE 1/4-20 HEX NUT 1/2 X 1/4" WASHER 3/16" GASKET MATERIAL 1/4-20 X 3/4" HEX HEAD CAP SCREW Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN WINDOW KITS Austin Window Kits are easily installed by making a cutout in the enclosure and attaching the window and frame in place. Frames are fabricated from 14 gauge steel with an ANSI 61 gray polyester powder coating or 14 gauge Type 304 stainless steel. The window is .25” clear acrylic plastic for both kits. A neoprene gasket around the frame preserves the watertight rating. All mounting hardware and installation instructions are furnished. AB-53WK AB-95WK AB-133WK AB-138WK AB-175WK AB-1711WK AB-2315WK AB-2919WK AB-3523WK S.S. Catalog Number AB-53WKX AB-95WKX AB-133WKX AB-138WKX AB-175WKX AB-1711WKX AB-2315WKX AB-2919WKX AB-3523WKX Window Size ExF Frame Size AxB Cut-Out Size CxD Weight 5x3 9x5.5 13x3 13x8 17x5.5 17x11 23x15 29x19 35x23 7.5x5.5 11.5x8 15.5x5.5 15.5x10.5 19.5x8 19.5x13.5 25.5x17.5 31.5x21.5 37.5x25.5 6.69x4.69 10.69x7.19 14.69x4.69 14.69x9.69 18.69x7.19 18.69x12.69 24.69x16.69 30.69x20.69 36.69x24.69 2 3 4 4 6 7 9 12 15 Accessories Catalog Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 175 AUSTIN MOUNTING FOOT KITS Austin Mounting Foot Kits contain four 14 gauge steel with an ANSI 61 gray polyester powder coating, galvanized, or Type 304 stainless steel external mounting feet and fasteners. Sealing washers are provided with each kit to maintain Type 4, 4X or Type 12 rating after field installation. Catalog Number Description AB-MTGFT-GAL AB-MTGFT-GRY AB-MTGFT-SS Galvanized Mounting Foot Kit Steel Mounting Foot Kit - Painted Gray Stainless Steel Mounting Foot Kit Accessories Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN DOOR STOP KITS Accessories Door Stop Kits are designed for securing the door of the enclosure in the open position. Kits can be mounted at the top or bottom of the door opening. Two holes must be drilled in the enclosure and in the door. The angle of the door is adjusted by a wingnut and the stop arm slides out of the way when the door is closed. Enclosures must have a “B” dimension of 16” or more and the door must open horizontally. Catalog Number Description AB-DSTOPK AB-DSTOPKX Plated Steel Door Stop Kit Stainless Steel Door Stop Kit Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 177 AUSTIN F L O O R S TA N D K I T S Austin Floor Stand Kits can be installed easily on Austin NEMA 4, 4X, and 12 single and double door enclosures. To install Floor Stand Kits, drill holes in bottom of enclosure and bolt on. Each kit includes two stands and is fabricated from 10 gauge steel with an ANSI 61 gray polyester powder coating or 12 gauge Type 304 stainless steel. Catalog Number AB-6SK8 AB-6SK10 AB-6SK12 AB-12SK8 AB-12SK10 AB-12SK12 AB-12SK16 AB-12SK20 AB-18SK8 AB-18SK10 AB-18SK12 AB-18SK16 AB-24SK8 AB-24SK10 AB-24SK12 AB-24SK16 Stainless Steel Catalog Number AB-6SK8SS AB-6SK10SS AB-6SK12SS AB-12SK8SS AB-12SK10SS AB-12SK12SS AB-12SK16SS AB-12SK20SS AB-18SK8SS AB-18SK10SS AB-18SK12SS AB-18SK16SS AB-24SK8SS AB-24SK10SS AB-24SK12SS AB-24SK16SS Floor Stand Height Depth of Enclosure "C" Dimension Weight 6 6 6 12 12 12 12 12 18 18 18 18 24 24 24 24 8 10 12 8 10 12 16 20 8 10 12 16 8 10 12 16 16 17 18 23 26 32 35 42 32 36 41 47 40 45 50 58 Accessories Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN O I LT I G H T H O L E S E A L S Catalog Number 050HS 075HS 100HS 125HS 150HS 200HS 250HS 300HS 350HS 400HS MHS PHS Stainless Steel Catalog Number 050HSSS 075HSSS 100HSSS 125HSSS 150HSSS 200HSSS 250HSSS 300HSSS 350HSSS 400HSS MHSSS PHSSS Description Hole Seal Diameter 1/2" - conduit 3/4" conduit 1" conduit 1 1/4" conduit 1 1/2" conduit 2" conduit 2 1/2" conduit 3" conduit 3 1/2" conduit 4" conduit 22.5mm pushbutton holes 30.5mm pushbutton holes 1.375 1.625 1.875 2.250 2.500 3.000 3.500 4.000 4.625 5.125 1.250 1.750 Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Accessories Knockouts, pushbutton holes, and conduit openings can be sealed against dust, dirt, oil, and water with Austin Hole Seals. Hole Seals are fabricated from 14 gauge steel with an ANSI 61 gray polyester powder coating or from 14 gauge Type 304 stainless steel. All Hole Seals are constructed with a neoprene oil resistant gasket, stainless steel stud and stainless steel wing nut. Phone: 336.468.2851 800.288.2851 179 AUSTIN DRIPSHIELD KITS Austin Dripshield Kits protect from dripping water and settling dust. Easily installed to enclosure with carriage bolts and sealing washers (hardware is furnished). Dripshield kits are fabricated from 12 gauge steel and provided standard with an ANSI 61 gray polyester powder coating or fabricated from Type 304 12 gauge stainless steel. (Stainless hardware is furnished). Catalog Number AB-12DK AB-16DK AB-20DK AB-24DK AB-30DK AB-36DK AB-42DK AB-48DK AB-60DK AB-72DK S.S. Catalog Number Enclosure Width "B" Dimension Weight AB-12DKX AB-16DKX AB-20DKX AB-24DKX AB-30DKX AB-36DKX AB-42DKX AB-48DKX AB-60DKX AB-72DKX 12 16 20 24 30 36 42 48 60 72 1 1 2 2 3 3 3 3 5 6 Accessories 1/4-20x3/4 CARRIAGE BOLT DRIPSHIELD DRIPSHIELD 12 "M AX . ENCLOSURE ENCLOSURE DOOR DOOR FACTORY INSTALLED DRIPSHIELD WELDED ON ENCLOSURE DRIPSHIELD FOR N-12 & N-4 (EXCEPT FS) INVERT DRIPSHIELD AS SHOWN FOR FREESTANDING N-12 AND N-4 ONLY 1/4 RUBBER FLAT WASHER 1/4 RUBBER FENDER WASHER 1/4-20 LOCKNUT Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 AUSTIN PRINT POCKETS Austin print pockets provide a convenient place to store charts, wiring diagrams, and other documentation in the enclosure. Self-adhesive backs make for easy installation on the inside of enclosure door. Thermoplastic pockets are provided standard light gray. AB-SMPRPKT AB-LGPRPKT Description Inside Dimensions AxBxC Small Print Pocket Large Print Pocket 5 7/8 x 5 7/8 x 1 9 1/8 x 8 5/8 x 1 3/16 C Accessories Catalog Number A B Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 181 AUSTIN L O C K S , L AT C H E S A N D ASSEMBLIES Tee Handles Catalog Number Description AB-9 AB-10 Tee handle with lock Tee handle Standard Lever Handles Locks & Latches Catalog Number Description AB-6 AB-7 Lever handle Lever handle with lock Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 A U S T I N L O C K S , L AT C H E S A N D A S S E M B L I E S Padlockable Lever Handle Catalog Number Description AB-18 Stainless Steel padlockable lever handle Catalog Number Description AB-8 AB-14 AB-17 AB-17X Flush cylinder lock Quarter-turn latch NEMA-4 Quarter-turn latch NEMA-4 Stainless Steel Quarter-turn latch Locks & Latches Locks And Latches Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 183 AUSTIN L O C K S , L AT C H E S A N D ASSEMBLIES JIC Quick Release Latch JIC Draw Pull Latches Catalog Number Description Catalog Number Description AB-15 AB-15X Plated Steel JIC Quick Release Latch Stainless Steel JIC Quick Release Latch AB-22 AB-22X JIC Quick release catch for field installation JIC Quick release catch stainless steel for field installation Locks & Latches Draw Pull Latch Locking Flush Latch Catalog Number Description Catalog Number Description AB-1 AB-1X Draw pull catch with hasp Stainless Steel Draw pull catch with hasp AB-16 Flush lift-latch with lock Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 A U S T I N L O C K S , L AT C H E S A N D A S S E M B L I E S Hasp and Staple JIC Clamp JIC Clamp Assembly Assembly Description Catalog Number Description AB-CLAMPSET-JIC JIC Clamp Assembly AB-3 Hasp and Staple Locks & Latches Catalog Number QuickRelease ReleaseNEMA NEMA Latch Quick Latch Catalog Number Description AB-20ASM AB-20 Quick release NEMA clamp assembly Quick release NEMA clamp Toggle Latch NEMA NEMA Clamp ClampAssembly Assembly Catalog Number Description AB-CLAMPSET-NEMA NEMA Clamp Assembly Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 Phone: 336.468.2851 800.288.2851 185 INDEX Austin products are listed in catalog by a catalog number consisting of the following alpha codes: (Air Conditioners, Heat Exchangers, Fans and Packaged Blowers are listed on the last page of index) AB-000000-CODE 1. AB - Austin Box 2. 000000 - H x W x D 3. CODE - Product Examples: AB-664SB - 6 x 6 x 4 Screw Cover Box Galvanized AB-1010120HW - 10 x 10 x 120 Hinge Cover Wireway Galvanized The following is a list of product codes and page location: Product Code Description ABD ABDB ABF ABM ABN ABNB ABP ABS AB-X ABX B DK DKX DP DSTOPK DSTOPKX EP EPG FN FP FSN FSN/DSC FSND FSND/DSC FTP GSB GSBG GST GSTG HC HCG HCGK HCK HS Extra Deep Pushbutton Enclosure Extra Deep Pushbutton Blank Cover Enclosure NEMA 4X Pushbutton Enclosure Slim-Line Pushbutton Enclosure Standard Pushbutton Enclosure Standard Pushbutton Blank Cover Enclosure Pendant Pushbutton Enclosure Sloping Pushbutton Enclosure (Ex. AB-7) Locks & Latches Extra Large Hinge Cover Pushbutton Enclosure with Back Panel Base Dripshield Kit Stainless Steel Dripshield Kit Double Door NEMA 12 Panel Door Stop Kit Stainless Steel Door Stop Kit NEMA 1 End Plate NEMA 1 End Plate Gray Flush NEMA 12 Enclosure Double Door NEMA 4 Panel NEMA 12 Freestanding Single Door Enclosure NEMA 12 Freestanding Single Door Disconnect Enclosure NEMA 12 Freestanding Double Door Enclosure NEMA 12 Freestanding Double Door Disconnect Enclosure Freestanding NEMA 12 Panel Gasket Screw Cover Box Galvanized Gasket Screw Cover Box Gray Gasket Screw Trough Galvanized Gasket Screw Trough Gray Hinge Cover Box Galvanized Hinge Cover Box Gray Hinge Cover Box Gray with Knockouts Hinge Cover Box with Knockouts Hole Seal Product Code Page Number Description Page Number Index Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 114,115 114,115 120,121 118,119 112,113 112,113 116,117 124,125 182-185 122,123 127-129 180 180 166,167 177 177 146,147 146,147 38,39 166,167 42,43 72-75,80-89 44,45 76-89 166,167 6,7 6,7 134,135 134,135 4,5 4,5 4,5 4,5 179 Phone: 336.468.2851 800.288.2851 INDEX Description HSSS HT HTG HW HWG HWGK HWK JBF JBFX JBH JBHX JBKTA JCA JCF JCFX JDH JDHX JEP JEPX JFC JFCX JFH JG JH JHA JHFX JL JL45 JL45X JL90 JL90X JN1 JN1X JN2 JN2X JN3 JN3X JP JPA JPX JR JRX JS JSOPK JTE JTEX JTR JTS JTS JTS JTSX JW JWFX JX JXL Stainless Steel Hole Seal Hinge Cover Trough Galvanized Hinge Cover Trough Gray Hinge Cover Wireway Galvanized Hinge Cover Wireway Gray Hinge Cover Wireway Gray with Knockouts Hinge Cover Wireway with Knockouts JIC Pull-Through Box Fitting JIC Pull-Through Stainless Steel Box Fitting JIC Pull-Through Bracket Hanger JIC Pull-Through Stainless Steel Bracket Hanger JIC Bracket Assembly JIC Clamp Cover Aluminum NEMA 4X Box JIC Pull-Through Cut-Off Fitting JIC Pull-Through Stainless Steel Cut-Off Fitting JIC Pull-Through Drop Hanger JIC Pull-Through Stainless Steel Drop Hanger JIC End Plate JIC End Plate Stainless Steel JIC Clamp Cover NEMA 4 Box JIC Clamp Cover NEMA 4X Stainless Steel Box JIC Continuous Hinge NEMA 4 Box JIC Gasket JIC Continuous Hinge Box JIC Continuous Hinge Aluminum Box JIC Continuous Hinge NEMA 4X Stainless Steel Box JIC Lift-Off Box JIC Pull-Through 45 Elbow JIC Pull-Through Stainless Steel 45 Elbow JIC Pull-Through 90 Elbow JIC Pull-Through Stainless Steel 90 Elbow JIC Pull-Through 1" Nipple JIC Pull-Through Stainless Steel 1" Nipple JIC Pull-Through 2" Nipple JIC Pull-Through Stainless Steel 2" Nipple JIC Pull-Through 3" Nipple JIC Pull-Through Stainless Steel 3" Nipple JIC Panel JIC Aluminum Panel JIC Stainless Steel Panel JIC Pull-Through Reducer JIC Pull-Through Stainless Steel Reducer JIC Screw Cover Box JIC Swing-Out Panel Kit JIC Pull-Through Tee JIC Pull-Through Stainless Steel Tee JIC Hinge Cover Trough JIC Pull-Through Telescope JIC Screw Cover Trough JIC Terminal Strap JIC Pull-Through Stainless Steel Telescope JIC Pull-Through Wireway JIC Pull-Through Wireway Nema 4X JIC Pull-Through Cross Large Oiltight Enclosure Page Number Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 179 132,133 132,133 144,145 144,145 144,145 144,145 150,151 150,151 150,151 150,151 172 106,107 150,151 150,151 150,151 150,151 150,151 150,151 98,99 102,103 96,97 150,151,153,155 90,91 104,105 100,101 92,93 150,151 150,151 150,151 150,151 150,151 150,151 150,151 150,151 150,151 150,151 164,165 164,165 164,165 150,151 150,151 94,95 168,169 150,151 150,151 140,141 150,151 138,139 172 150,151 148,149 152,153 150,151 110,111 Phone: 336.468.2851 800.288.2851 Index Product Code 187 INDEX Index Product Code Description Page Number JXX L45 L45G L90 L90G LBF LBH LCC LCF LCS LDH LEP LFP LJB LK LL45 LL45N LL45T LL90 LL90L LL90N LL90R LL90T LM LN1 LN2 LN3 LNP LR LT LTS LTT LW LX MTGFT N N/ABDSC N/DSC NA NBKTA ND ND/FDSC NF NF/DSC NFA NFD NFX NFX/DSC NSOPK NTS PA PBC JIC Pull-Through Stainless Steel Cross NEMA 1 45 Elbow NEMA 1 45 Elbow Gray NEMA 1 90 Elbow NEMA 1 90 Elbow Gray JIC Lay-In Box Fitting JIC Lay-In Bracket Hanger JIC Lay-In Straight Counter Clockwise Transposition JIC Lay-In Cut-Off Fitting JIC Lay-In Straight Clockwise Transposition JIC Lay-In Drop Hanger JIC End Plate JIC Lay-In Flat Sealing Plate JIC Lay-In Junction Box Louver Kit JIC Lay-In Top Open 45 Elbow JIC Lay-In Inside Open 45 Elbow JIC Lay-In Outside Open 45 Elbow JIC Lay-In Top Open 90 Elbow JIC Lay-In Counter Clockwise Transposition 90 Elbow JIC Lay-In Inside Open 90 Elbow JIC Lay-In Clockwise Transposition 90 Elbow JIC Lay-In Outside Open 90 Elbow Large O.E.M. Box JIC Lay-In 1" Nipple JIC Lay-In 2" Nipple JIC Lay-In 3" Nipple JIC Lay-In 90 Sealing Plate JIC Lay-In Reducer JIC Lay-In Tee Outside Open JIC Lay-In Telescope JIC Lay-In Tee Top Open JIC Lay-In Wireway JIC Lay-In Cross Mounting Foot Kit NEMA 12 Enclosure NEMA 12 Allen-Bradley Disconnect Enclosure NEMA 12 Disconnect Enclosure NEMA 12 Aluminum Enclosure NEMA Bracket Assembly NEMA 12 Double Door Enclosure NEMA 12 Double Door Disconnect Enclosure NEMA 4 Enclosure NEMA 4 Disconnect Enclosure NEMA 4X Aluminum Enclosure NEMA 4 Double Door Enclosure NEMA 4X Stainless Steel Enclosure NEMA 4X Stainless Steel Disconnect Enclosure NEMA Swing-Out Panel Kit NEMA Terminal Strap NEMA 1 Panel Adapter Oiltight Consolet Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 150,151 146,147 146,147 146,147 146,147 158,159 158,159 156,157 158,159 156,157 158,159 158,159 158,159 158,159 174 156,157 156,157 156,157 156,157 156,157 156,157 158,159 158,159 12,13 158,159 158,159 158,159 158,159 158,159 156,157 158,159 156,157 154,155 158,159 176 32-35 64-67 48-51, 56-63 40,41 173 36,37 68-71, 80-89 24,25 52-63 30,31 26,27 28,29 52-63 170,171 173 146,147 126-129 Phone: 336.468.2851 800.288.2851 INDEX Description Page Number PRPKT PS R RB RBG RG RT RTG SB SBG SBGK SBK SK SKX SL SLX SM ST STE STG SW SWG SWGK SWK T TE TEG TL TP TPX TS TSG UC UCG UH UHG WDN WK WKX WL WS X XG YC YD YEC YHL YHT YPA YVL YVT YW YX Print Pocket Pedestal NEMA 1 Reducer Rainproof Box Galvanized Rainproof Box Gray NEMA 1 Reducer Gray Rainproof Trough Galvanized Rainproof Trough Gray Screw Cover Box Galvanized Screw Cover Box Gray Screw Cover Box Gray with Knockouts Screw Cover Box with Knockouts Floor Stand Kit Stainless Steel Floor Stand Kit Style-Line Enclosure Style-Line Enclosure Stainless Steel Small O.E.M. Box Screw Trough Galvanized Small Oiltight Enclosure Screw Trough Gray Screw Cover Wireway Galvanized Screw Cover Wireway Gray Screw Cover Wireway Gray with Knockouts Screw Cover Wireway with Knockouts Telephone Cabinet NEMA 1 Tee NEMA 1 Tee Gray Telephone Cabinet Flush NEMA Panel Stainless Steel NEMA Panel NEMA 1 Telescope NEMA 1 Telescope Gray NEMA 1 U-Connector NEMA 1 U-Connector Gray NEMA 1 U-Hanger NEMA 1 U-Hanger Gray NEMA 12 Double Door Wall-Mount Enclosure Window Kit Stainless Steel Window Kit Large Weatherproof Cabinet Small Weatherproof Cabinet NEMA 1 Cross NEMA 1 Cross Gray U-Connector (X-Ray) 60" Divider (X-Ray) End Cap (X-Ray) Horizontal 90 Elbow (X-Ray) Horizontal Tee (X-Ray) Panel Adapter (X-Ray) Vertical 90 Elbow (X-Ray) Vertical Tee (X-Ray) Lay-In Duct for X-Ray Equipment Cross (X-Ray) Austin Electrical Enclosures Post Office Box 2320 Yadkinville, NC 27055 181 127-129 146,147 8,9 8,9 146,147 136,137 136,137 2,3 2,3 2,3 2,3 178 178 20-23 20-23 10,11 130,131 108,109 130,131 142,143 142,143 142,143 142,143 14,15 146,147 146,147 14,15 166,167 166,167 146,147 146,147 146,147 146,147 146,147 146,147 46,47 175 175 18,19 16,17 146,147 146,147 162,163 162,163 162,163 162,163 162,163 162,163 162,163 162,163 160,161 162,163 Phone: 336.468.2851 800.288.2851 Index Product Code 189 NOTES NOTES NOTES