LED Tube Light – 100 LED Fluorescent Tube

advertisement
Energy Focus, Inc.
LED Light Tube (Linear Fluorescent Replacement)
LED Light Tube retrofit Installation Instruction
The product package includes the following components:
1. LED Tube - 100 Series (1 unit)
2. UL Safety Fixture Label (1 self-adhesive)
3. Installation Instruction (5 pages)
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
"THIS PRODUCT SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST NEC AND/OR LOCAL AUTHORITY HAVING
JURISDICTION. INSTALLATION SHALL BE PERFORMED BY A QUALIFIED ELECTRICIAN UNDERSTANDING THE
CONSTRUCTION AND OPERATION OF THIS PRODUCT AND THE ELECTRICAL REQUIREMENTS INVOLVED."
-
Risk of fire or electric shock: ALWAYS disconnect or terminate power to fixture prior to installation, or replacement,
of LED Light Tubes. Failure to do so may result may in shock and/or serious injury
-
Risk of fire or electric shock: The operating voltage of these products is 110-277 VAC. Installer shall verify operating
voltage at the luminaries prior to installation.
-
Risk of fire or electric shock: Install retrofit LED Tube Lamps only in new or existing linear fluorescent luminaries
modified as described in this manual, that meet the minimum dimension requirements as shown in the illustrations
below.
-
Risk of fire or electric shock: To prevent wiring damage or abrasion, protect wiring from exposed edges of sheet
metal or other sharp objects that may be present in the fixture.
Do not make modifications to or alter fixture housing, ballast enclosure or electrical components other than those
required for proper installation.
THIS RETROFIT ASSEMBLY IS AN APPROVED COMPONENT OF A LINEAR FLUORESCENT LUMINAIRE KIT WHERE THE
SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR LOCAL AUTHORITIES HAVING JURISDICTION.
-
For use only with UL and C-UL Listed surface mounted or recess mounted linear fluorescent luminaries with or without
diffuser.
-
Fluorescent lamp holders within fixture shall be rewired to line voltage and will no longer operate the original fluorescent lamp.
Included fixture warning label must be affixed to luminaire in a visible location after installation.
-
Suitable for dry locations only when used with open, surface, recessed and totally enclosed fixtures. May be used in wet
locations when installed in a suitable UL-listed wet location enclosed fixture.
-
Do not use with dimmers; LED Lamps are NOT dimmable
-
THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY LIGHTING (BATTERY TYPE) SYSTEMS FOR
FLUORESCENT LIGHTING PRODUCTS.
Please address all inquiries to:
Energy Focus Inc.
32000 Aurora Road
Solon, OH 44139
(800) 327-7877
customerservice@efoi.com
Page 1 of 5
Energy Focus, Inc. 32000 Aurora Road Solon, OH 44139 T (800) 327-7877 (440) 715-1300 F (440)715-1314 W energyfocusinc.com
© 2013 Energy Focus, Inc. All Rights Reserved. Energy Focus, Inc. reserves the right to changes specifications for product improvement without prior notice.
Energy Focus, Inc.
Before retrofit please confirm the existed fluorescent luminaries' Type is compatible with defined dimensions below.
Part Number
UL Model
No.
One Lamp
Fixture
Minimum Luminaire dimensions: Length x Width
Two Lamp
Three Lamp
Four Lamp
Fixture
Fixture
Fixture
LEDFLT10-7XX-24-100X
3AJ10086
24.49" x 5.71"
24.49" x 11.34"
24.49" x 16.54"
24.49" x 21.65"
LEDFLT10-7XX-48-100X
3AJ10166
48.11" x 5.71"
48.11" x 11.34"
48.11" x 16.54"
48.11" x 21.65"
Electrical Characteristics (Typical value):
Part Number
LEDFLT10-7XX-24-100X
LEDFLT10-7XX-48-100X
UL Model
No.
3AJ10086
3AJ10166
Size
2 ft
4 ft
Voltage
AC (V)
100 - 277
100 - 277
Current
AC (A)
0.06
0.12
Power
(W)
8
16
Rated
Frequency
(Hz)
50/60
50/60
Power
Factor
0.88
0.88
Page 2 of 5
Energy Focus, Inc. 32000 Aurora Road Solon, OH 44139 T (800) 327-7877 (440) 715-1300 F (440)715-1314 W energyfocusinc.com
© 2013 Energy Focus, Inc. All Rights Reserved. Energy Focus, Inc. reserves the right to changes specifications for product improvement without prior notice.
Energy Focus, Inc.
1.
Dimension:
Part Number
UL Model
No.
Size
3AJ10086
3AJ10166
2 ft
4 ft
LEDFLT10-7XX-24-100X
LEDFLT10-7XX-48-100X
A
MAX
23.22"
47.22"
B
MIN
23.4"
47.4"
C
MAX
23.5"
47.5"
MIN
/
/
MAX
23.78"
47.78"
D
MAX
ɸ 1.2598"
ɸ 1.2598"
2.
Environmental requirements:
Operating temperature: -20 to +40°C
Storage temperature: -30 to +60°C
Working humidity: 30% to 85%
Storage humidity: 10% to 90%
Storage and operating environment: Normal indoor ventilation and non-corrosive environments
3.
Installation
Socket type
G13
G13
DANGER -RISK OF SHOCK-DISCONNECT POWER
TO LIGHT FIXTURE BEFORE INSTALLATION
-
To replace fluorescent light tube with LED light tube, the wiring must be installed according to these instructions to ensure
a complete and safe installation of the LED light tube
-
The luminaire shall be grounded.
LED Light Tube Wiring Diagram:
Page 3 of 5
Energy Focus, Inc. 32000 Aurora Road Solon, OH 44139 T (800) 327-7877 (440) 715-1300 F (440)715-1314 W energyfocusinc.com
© 2013 Energy Focus, Inc. All Rights Reserved. Energy Focus, Inc. reserves the right to changes specifications for product improvement without prior notice.
Energy Focus, Inc.
Rewiring Guide for Various Fluorescent Ballasts
Inductance ballast
Pre-retrofit wiring
Required alterations
Post retrofit wiring
Electronic ballast
Pre-retrofit wiring
Required alterations
Post retrofit wiring
Multiple Lamp Installation Guide
Pre-retrofit wiring
Required alterations
Post retrofit wiring
Note: LED Tube Lamp requires single end power only; wiring to one side of the fixture is sufficient. Ensure
Lamp end labeled “Power end here” is installed to the live circuit.
CAUTION:
LAMP HOLDERS MUST BE NON-SHUNTED. POWER FLOWS THROUGH LED LIGHT TUBE
1.
Turn off the power to the light fixture at the breaker panel before installation.
2.
If retrofitting an enclosed fixture open the diffuser from the light fixture.
3.
Remove existing fluorescent lamps. Please dispose or recycle these items properly in accordance with local
requirements as they contain mercury
4.
Open the wiring cover to expose the fluorescent ballast.
5.
Cut the wires shown as the diagram above. Optional: Remove ballast and starter and dispose or recycle in accordance with
local requirements.
6.
Make the new wire connection for new branch circuit wiring required and shown as in diagram above.
The labeled end of LED Light Tube is the live, input powered end. The opposite end is electrically isolated and serves as
means of mechanical support only.
7.
Reinstall the ballast cover over the wiring channel.
8.
IMPORTANT: Install the fixture warning label provided in a visible location after the LED Light Tubes are installed.
"Notice: This luminaire has been modified and no longer operates Fluorescent Lamps. Use only Energy Focus, Inc. Model
LEDFLT10-7XX-XX-100X LED self-ballasted lamps for lamp replacement. (Tel: (888) 704-2276 www.energyfocusinc.com)”
inside the fixture in an easily visible location to anyone changing lamps, possibly on the cover over the wiring channel.
Page 4 of 5
Energy Focus, Inc. 32000 Aurora Road Solon, OH 44139 T (800) 327-7877 (440) 715-1300 F (440)715-1314 W energyfocusinc.com
© 2013 Energy Focus, Inc. All Rights Reserved. Energy Focus, Inc. reserves the right to changes specifications for product improvement without prior notice.
Energy Focus, Inc.
9.
Install the LED tube lamps, close the diffuser.
10. After all LED tube lamps are installed, restore the power at the circuit breaker and turn the lights on.
Example ‘A’
Light directed away from Fixture mounting location
LED Light Tube settings at 0°
1.
Verify arrowhead direction before installing. If the arrow does not point to 0°, rotate lamp bi-pin to 0°. The rotation range of
the lamp socket is 0~90° as indicated on the socket cap, refer to end view in diagram. Do not rotate beyond this range as
it will damage the lamp socket and possibly cause failure of the LED Light Tube.
2.
Install the tube to the lamp holder, the direction of the pins shall be parallel to the fixture base, refer to diagram (2).
3.
After installation, light tubes LEDs are parallel with the surface of the fixture. Refer to diagram (3).
Example ‘B
Light directed along Fixture mounting surface
LED Light Tube settings at 90°
1.
Verify arrowhead direction before installing. If the arrow does not point to 90°, rotate lamp bi-pin to9 0°. The rotation range
of the lamp socket is 0~90° as indicated on the socket cap, refer to end view in diagram. Do not rotate beyond this range
as it will damage the lamp socket and possibly cause failure of the LED Light Tube.
2.
Install the tube to the lamp holder, the direction of the pins shall be parallel to the fixture base, refer to diagram (2).
3.
After installation, light tubes LEDs are perpendicular to the surface of the fixture. Refer to diagram (3).
Please address all inquiries to:
Energy Focus Inc.
32000 Aurora Road
Solon, OH 44139
(800) 327-7877
customerservice@efoi.com
Page 5 of 5
Energy Focus, Inc. 32000 Aurora Road Solon, OH 44139 T (800) 327-7877 (440) 715-1300 F (440)715-1314 W energyfocusinc.com
© 2013 Energy Focus, Inc. All Rights Reserved. Energy Focus, Inc. reserves the right to changes specifications for product improvement without prior notice.
Download