Measuring Instruments

advertisement
Measuring Instruments
Measuring Instruments
wa_sg05811
wa_sg04911
100
Measuring Instruments
Measuring Instruments
PHASE OUT TYPE
Power Meter KWZ
System
Rated Current
Type Designation
Article No.
Units per package
1N
40 A
KWZ-230
286839
1 / 60
3N
3N
5 A,CT
63 A
KWZ-3PH
KWZ-3PH-63
110825
110826
1 / 30
1 / 30
System Rated Current
Type Designation
Article No.
Units per package
1N
1N
1N
1N
1N
1N
1N
1N
32 A
32 A, MID cert.
40 A
40 A, MID cert.
80 A
80 A, MID cert.
125 A
125 A, MID cert.
EME1P32
EME1P32MID
EME1P40
EME1P40MID
EME1P80
EME1P80MID
EME1P125
EME1P125MID
167397
167398
167399
167400
167401
167402
167403
167404
1
1
1
1
1
1
1
1
3N
3N
3N
3N
3N
3N
80 A
80 A, MID cert.
5 A, CT
5 A, CT MID cert.
125 A
125 A, MID cert.
EME3P80
EME3P80MID
EME3PCT
EME3PCTMID
EME3P125
EME3P125MID
167413
167414
167417
167418
167415
167416
1
1
1
1
1
1
SG10007
KWZ-3PH-63
Power Meter EME
wa_sg05311
EME1P125
Accessories Current Transformer
• Z-MG/WAK: maximum cable diameter 21 mm
• Z-MG/WAS: maximum busbar cross section 30 x 10 mm, 40 x 10 mm or 50 x 12 mm,
maximum cable diameter 23 mm / 30 mm - according to type, see dimension diagramms
Communication modules
Designation
Type Designation
Article No.
Units per package
Communication module
Communication module
MBUS
Communication module
with MODBUS
EMECLAN
EMECMBUS
167419
167420
1
1
EMECMODB
167421
1
System Rated Current
Type Designation
Article No.
Units per package
3N
3N
3N
3N
3N
3N
EME3PCTB
EME3PCTBMID
EME3P63B
EME3P63BMID
EME3P63BMODBUS
EME3P63BMODBUSMID
167405
167406
167407
167408
167409
167410
1
1
1
1
1
1
EME3P80BMID
EME3P80BMODBUSMID
167411
167412
1
1
wa_sg00312
EMECMODB
Basic Devices
wa_sg05711
3N
3N
5 A, CT S0
5 A, CT S0 MID cert.
63 A, S0
63 A, S0 MID cert.
63 A, MODBUS
63 A, S0 MODBUS
MID cert.
80 A, S0 MID cert.
80 A, S0 MODBUS
MID cert.
101
Measuring Instruments
Multimeter EME3PMMCT5
Communication link
Type Designation
Article No.
Units per package
S0
EME3PMMCT5
171631
1
LAN Server Modbus/TCP EMELSMODBUS
PHASE OUT TYPE
Description
Type Designation
Article No.
Units per package
Data Concentrator with
Modbus/TCP
EMELSMODBUS
170509
1
Function/Measuring Range
Type Designation
Article No.
Units per package
248228
248229
248227
248223
248224
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
Z-MG/AD-20
Z-MG/AD-999
Z-MG/VD-600
Z-MG/VD+AD
248225
248226
248222
263140
1 / 30
1 / 30
1 / 30
1 / 30
Z-MG/VD+AD+S
263141
1 / 30
Analogue Ammeter and Voltmeter Z-MG
SG2802
Ammeter/0-10 A
Ammeter/0-40 A
Ammeter transformer/0-600A, x/5A
Voltmeter/0-250 V
Voltmeter/0-500 V
PHASE OUT TYPE
SG30012
Z-MG/AA-10
Z-MG/AA-40
Z-MG/AA5-WS
Z-MG/VA-250
Z-MG/VA-500
Digital Ammeter and Voltmeter Z-MG
Ammeter/0-20 A
Ammeter transformer/0-999A, x/5A
Voltmeter/0-600 V
Ammeter+Voltmeter/0-8kA, x/5A;
0-600V
Ammeter+Voltmeter/0-8kA, x/5A;
0-600V, 2 programmable
contacors
Accessories
Current transformer Z-MG/WAS.., Z-MG/WAK..
Exchangeable scale Z7-MG/WS-.. for Z-MG/AA5-WS
102
Measuring Instruments
Digital Ammeter and Voltmeter EM
Description
Type Designation
Article No.
Units per package
Ammeter
Voltmeter
EMA20
EMV600
167423
167422
1
1
wa_sg00212
Accessories Current Transformer
• Z-MG/WAK: maximum cable diameter 21 mm
• Z-MG/WAS: maximum busbar cross section 30 x 10 mm, 40 x 10 mm or 50 x 12 mm,
maximum cable diameter 23 mm / 30 mm - according to type, see dimension diagramms
Function/Ratio/Measuring Range
Type Designation
Article No.
Units per package
Current transf. f. cable / 40/5
Current transf. f. cable / 50/5
Current transf. f. cable / 60/5
Current transf. f. cable / 80/5
Current transf. f. busbar / 100/5
Current transf. f. busbar / 150/5
Current transf. f. busbar / 200/5
Current transf. f. busbar / 250/5
Current transf. f. busbar / 300/5
Current transf. f. busbar / 400/5
Current transf. f. busbar / 500/5
Current transf. f. busbar / 600/5
Current transf. f. busbar / 800/5
Current transf. f. busbar / 1000/5
Scale to Z-MG/AA5-WS / 0-50
Scale to Z-MG/AA5-WS / 0-60
Scale to Z-MG/AA5-WS / 0-80
Scale to Z-MG/AA5-WS / 0-100
Scale to Z-MG/AA5-WS / 0-150
Scale to Z-MG/AA5-WS / 0-200
Scale to Z-MG/AA5-WS / 0-250
Scale to Z-MG/AA5-WS / 0-300
Scale to Z-MG/AA5-WS / 0-400
Scale to Z-MG/AA5-WS / 0-500
Scale to Z-MG/AA5-WS / 0-600
Z-MG/WAK-40
Z-MG/WAK-50
Z-MG/WAK-60
Z-MG/WAK-80
Z-MG/WAS-100
Z-MG/WAS-150
Z-MG/WAS-200
Z-MG/WAS-250
Z-MG/WAS-300
Z-MG/WAS-400
Z-MG/WAS-500
Z-MG/WAS-600
Z-MG/WAS-800
Z-MG/WAS-1000
Z7-MG/WS-50
Z7-MG/WS-60
Z7-MG/WS-80
Z7-MG/WS-100
Z7-MG/WS-150
Z7-MG/WS-200
Z7-MG/WS-250
Z7-MG/WS-300
Z7-MG/WS-400
Z7-MG/WS-500
Z7-MG/WS-600
101619
101620
101621
101622
101623
101625
101626
101627
101628
101629
101630
101631
101632
101624
850001066
850001086
850001087
850001067
850001068
850001069
850001070
850001088
850001089
850001092
850001093
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
SG8797
SG8897
PHASE OUT TYPE
PHASE OUT TYPE
Operating Hours Counter BSZ
Readout
Rated Voltage
Type Designation
Article No.
Units per package
5+2digit
5+2digit
230V 50Hz
24V 50Hz
BSZ/230
BSZ/24
276309
276308
1 / 60
1 / 60
SG15805
103
Measuring Instruments
Operating Hours Counter ASOHC230
Readout
Rated Voltage
Type Designation
Article No.
Units per package
ASOHC230
167424
1
wa_sg04411
5+2stellig 230V 50Hz
PHASE OUT TYPE
Pulse Counter Z-IMZ
Readout
Rated Voltage
Type Designation
Article No.
Units per package
7digit
7digit
230V 50Hz
24V 50Hz
Z-IMZ/230
Z-IMZ/24
248206
248207
1 / 60
1 / 60
SG2702
Pulse Counter ASPC230
Readout
Rated Voltage
Type Designation
Article No.
Units per package
7digit
230V 50Hz
ASPC230
167425
1
wa_sg05011
104
Measuring Instruments
Power Meter KWZ
•
•
•
•
•
Power meter according to IEC/EN 61036 for sub-measurement
For active energy
3-phase AC types also suitable for uneven load
Type KWZ-230: single-phase kWh-meter
Type Z-KWZ-3PH: for 4-wire 3-phase AC system with external transducer
X/5A; Type Z-MG/WA.
Transducer ratios according to table
• Type Z-KWZ-3PH-25: For 4-wire 3-phase AC system with direct connection
Connection diagram
KWZ-230
L
N
1
4
Output
3
6
7
8
Load
Technical Data
KWZ-230
Electrical
Rated voltage Un
Working range
Rated current Ib
Maximum currentImax
Rated frequency
Overload short time
Back-up fuse
230 V AC
0.9 - 1.2 x Un
10A, direct
40 A
50/60Hz
–
MCB: C40
40 A gG/gL
no
from measurement
–
2W
sinusoidal
cosϕ=0.5 inductive to cosϕ=0,8 capacitive
1
0.1 kWh
640 pulse/kWh
<8 VA
–
Sealable
Auxiliary voltage
Power consumption
Power loss
Input signal
Power factor
Accuracy class
Resolution
LED signal
Own consumption per phase
DIP adjustment switch for
transducer ratios
Pulse output rated values
Pulse value (jumper)
Switching contact (potential-free)
Rated peak withstand voltage(1.2/50) µs
Test voltage 50Hz/1min.
5-48V DC, 50mA
10 pulse/kWh
1 NO
5 kV
2.5 kV
Mechanical
Frame size
Device height
Device width
Weight
Calibrateable
Display
Maximum display reading
Height of figures
Mounting
Degree of protection, built-in
Upper and lower terminals
Terminal capacity
Tightening torque of terminal screws
Permitted relative humidity
Perm. ambient temperature range
Flame class acc. to UL 94
45 mm
90 mm
35 mm (2MU)
180 g
no
5+1digit
99999,9kWh
4 mm
quick fastening on DIN rail IEC/EN 60715
IP51
lift terminals
12mm2 (2.5mm2 pulse-outp.)
2 Nm
90%
-5 to +55°C
V0
Dimensions (mm)
KWZ-230
176
Measuring Instruments
Power Meter KWZ-3PH
•
•
•
•
•
Power meter according to EN 62053 for sub-measurement
For active/reactive energy
For unbalanced load
Programming by front keyboard, 2 keys
Sealability front frame and terminal
Connection diagram
KWZ-3PH
KWZ-3PH-63
Technical Data
Electrical
Rated voltage Un
Working range
Rated current Ib
Maximum current Imax
Maximum back-up fuse
Rated frequency
Frequency range
Power consumption per phase (current path)
Overcurrent short time
Auxiliary voltage
Input signal
Accuracy class
Metering LED
Pulse output rated values
Switching contact (potential-free)
Pulse frequency (selectable)
Pulse duration (selectable)
Programmable parameters
Overvoltage category
Insulation voltage rating (phase - phase)
Rated impulse withstand voltage (1.2/50) µs
Test voltage
Input/pulse-output
all circuits and earth
Protection class
Mechanical
Frame size
Device height
Device width
Weight
Display
Digit height
Maximum display
Resolution
Measurement display
Mounting
Degree of protection, front frame / terminals
Upper and lower terminals
Terminal capacity
Current terminal
Voltage terminal
Permitted relative air humidity
Reference temperature
Perm. ambient temperature range
Storage and transportation temperature range
Pollution degree
KWZ-3PH
KWZ-3PH-63
230-240/400-415 V AC
110-254/190-440 V AC
1 and 5 A
6A
MCB: B10 or 10A gG/gL
(only voltage pathes)
50 and 60 Hz
47-63 Hz
≤0.5 VA (each phase)
20 x Imax / 0.5 s
from measurement
sinusoidal
1
1 pulse / 0.1 Wh
max. 110V AC/DC, 50mA
Opto coupler
S0-Interface according
DIN 43864 / EN 62053-31
1 pulse / 10Wh-100Wh-1kWh-10kWh
optional 1 pulse / 10VArh-100VArh1kVArh-10kVArh
50-100-150-200-300-400-500 ms
connection (1-phase, 3-phases
3- or 4-wire), external VT and
CT-ratio, power demand,
pulse output
III
450 V
5 kV
230-240/400-415 V AC
110-254/190-440 V AC
10 A
63 A
MCB: C63 or 63A gG/gL
2.75 kV
4 kV
II
50 and 60 Hz
47-63 Hz
≤4 VA (each phase)
30 x Imax / 10 ms
from measurement
sinusoidal
1
1 pulse / Wh
max. 110V AC/DC, 50mA
Opto coupler
S0-Interface according
DIN 43864 / EN 62053-31
1 pulse / 1Wh-10Wh--100Wh1kWh-10kWh
optional 1 pulse / 10VArh-100VArh1kVArh-10kVArh
50-100-150-200-300-400-500 ms
connection (3-phases 3- or 4-wire),
counting, power demand, pulse
output
III
300 V
5 kV
2.75 kV
4 kV
II
45 mm
45 mm
89 mm
89 mm
71.2 mm
71.2 mm
260 g
260 g
LCD 8 digit
LCD 8 digit
6 mm
6 mm
setable
999999,99 kWh
setable
10 W
subdivided on 6 pages
subdivided on 7 pages
quick fastening on DIN rail IEC/EN 60715
IP52 / IP20
IP52 / IP20
screw terminals
screw terminals
rigid cable 0.05-4mm2
flexible cable 0.05-2.5mm2
rigid cable 0.05-4mm2
flexible cable 0.05-2.5mm2
suitable for tropical dissipation
23°C ±2°C
-5 to +55°C
-25 to +70°C
2
177
input: rigid cable 1-10mm2
flexible cable 1-13mm2
output: rigid cable 1-4mm2
flexible cable 1-3mm2
suitable for tropical dissipation
23°C ±2°C
-5 to +55°C
-25 to +70°C
2
Measuring Instruments
Dimensions (mm)
Wiring diagrams KWZ-3PH
1-phase
3-phases
3-wires
balanced
3-phases
3-wires
unbalanced
3-phases
3-wires
unbalanced
3-phases
3-wires
unbalanced
3-phases
3-wires
unbalanced
3-phases
4-wires
balanced
3-phases
4-wires
unbalanced
Wiring diagrams KWZ-3PH-63
3-phases
3-wires
3-phases
4-wires
178
Measuring Instruments
Energy-meters single-phase 32-40 A, EME
• Digital active energy meter with measurement I - U - Hz - PF measurement
of active instantaneous power, by IR side set up communication - 1 tariff
- 1 S0
• Active energy-meters for single-phase alternating current with a, 7 digits
counter. These meters have 1 S0 output generating pulses for remote processing of the active energy measurements for 1 tariff.
• Display LCD
• For direct connection 32 A and 40 A
• 7 digits for energy values indication
• Accuracy class 1 for active energy according to EN 50470-3 (B)
• Most attractive operating range current (Ist ... Imax) - for direct connection 32
A and 40 A = 0.020 ... 32 A or 40 A
• The standard versions are designed to be combined with the communication module
• Active energy register zero setting (not for MID types)
• Active energy register in T1 import/export
• Instantaneous power active import/export display
• Current RMS
• Voltage RMS
• Power factor
• Frequency
• FW release
• FW checksum
• 1 DIN modules wide (18 mm)
Technical Data
EME1P32
EME1P32MID EME1P40
EME1P40MID
direct connection 32 A
direct connection 40 A
EN 50470-1, EN 50470-3 and EN 62053-31
Data in compliance with
General characteristics
Housing
DIN 43880
DIN
1 modules
1 modules
Mounting
EN 60715
35 mm
DIN rail
DIN rail
Depth
mm
70
70
Reference standard
active energy
EN 50470-1-3, EN 62053-31 EN 50470-1-3, EN 62053-31
Operating features
Connectivity
to single-phase network
n° wires
2
2
Storage of energy values and configuration
FRAM memory
yes
yes
Supply
Rated control supply voltage Un
VAC
230
230
Operating range voltage
V
184 ... 276
184 ... 276
Rated frequency fn
Hz
50
50
Rated power dissipation (max.) Pv
VA (W)
≤8 (0.6)
≤8 (0.6)
Overload capability
Voltage Un
continuous
V
276
276
momentary (1 s)
V
300
300
continuous
A
32
40
Current Imax
momentary (10 ms)
A
960
1200
Display (readouts)
Display type
LCD
n° digits
7 (2 decimals)
7 (2 decimals)
digit dimensions
mm x mm
6.00 x 3
6.00 x 3
Active energy: 1 display, 7-digit
kWh
0.00 ... 999999.9
0.00 ... 999999.9
Instantaneous tariff measurement
1
1
1 display, 1-digit
T1
T1
Display period refresh
s
1
1
Measuring accuracy
at 23 ±1°C, referred to nominal values
Active energy and power acc.to EN 50470-3
%
±1 (B)
±1 (B)
Measuring input
Type of connection
phase/N
direct
direct
Operating range voltage phase/N
V
184 ... 276
184 ... 276
Current Iref
A
5
5
Current Imin
A
0.25
0.25
Operating range current (Ist ... Imax)
direct connection
A
0.02 ... 32
0.02 ... 40
Frequency
Hz
50
50
Input waveform
alternating
alternating
Starting current for energy measurement (Ist)
mA
20
20
Pulse output S0
acc.to EN 62053-31
Pulse output
for active energy
yes
yes
Pulse quantity
Imp/kWh
1000
1000
Pulse duration
ms
90
90
Required voltage
min. (max.)
VAC (DC)
5 ... 230 ±5% (5 ... 300)
5 ... 230 ±5% (5 ... 300)
Permissible current
pulse ON (max. 230 V AC/DC)
mA
90
90
Permissible current
impuls OFF (leakage currrent max. 230 V AC/DC)
µA
1
1
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
5000
5000
179
Measuring Instruments
Safety acc. to EN 50470-1
Indoor meter
Degree of pollution
Operational voltage
V
AC voltage test (EN 50470-3, 7.2)
kV
Impulse voltage test
1.2/50 µs-kV
Protection class (EN 50470)
class
Housing material flame resistance
UL 94
class
Safety-sealing between upper and lower housing part
Adaptor for Communication
Plug-and-play technology
LAN Interface (TCP/IP) Ethernet 802.3
EMECLAN
Modbus RTU, Ascii
RS-485 3 wires
EMECMODB
M-Bus
RS-485 2 wires
EMECMBUS
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Type cage pulse output blade for slotted screw
mm
Terminal capacity main current paths
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Terminal capacity pulse outlet
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Mechanical environment
Electromagnetic environment
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity (not condensation)
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Degree protectionhousing when mounted in front (terminal)
-
EME1P32
EME1P32MID
direct connection 32 A
EME1P40
EME1P40MID
direct connection 40 A
yes
2
300
4
6
II
yes
2
300
4
6
II
V0
V0
no
yes
no
yes
•
10/100 Mbps
up to 19.200 bps
up to 9.600 bps
•
10/100 Mbps
up to 19.200 bps
up to 9.600 bps
PZ1
PZ0
PZ1
PZ0
16
16
16
16
0.15 (2.5)
0.15 (2.5)
0.15 (4)
0.15 (4)
M1
E2
-10 ... +55
-25 ... +70
≤80
M1
E2
-10 ... +55
-25 ... +70
≤80
±0.075
±0.075
IP51*)/IP20
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
Dimensions (mm)
Connection diagram
A Miniature Circuit Breaker of 32A
or 40A is recommended.
180
Measuring Instruments
Energy-meters single-phase 80 A, EME
• Digital active and reactive energy meter with measurement of active and
reactive instantaneous power, by IR side set up communication - 2 tariffs 2 S0
• Active and reaktive (not for MID types) energy-meters for single-phase
alternating current with either 1, 7 digits digital counters. These meters
have 2 S0 output generating pulses for remote processing of the energy
active and reactive measurements for 2 tariffs.
• Green backlighted LCD
• For direct connection 80 A
• 7 digits for energy values indication
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Accuracy class 2 for reactive energy and power according to EN 62053-23
• Most attractive operating range current (Ist ... Imax) for direct connection
80 A = 0.02 ... 80 A
• The standard versions are designed to be combined with the communication module
• Energy register zero setting (not for MID types)
• Energy register for import and export
• Instantaneous power active and reactive display (MID types: only active
power)
• Sealable terminal covers
• 2 DIN modules wide (36 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME1P80
EME1P80MID
direct connection 80 A
EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31
DIN 43880
EN 60715
DIN
35 mm
mm
active energy
reactive energy - pulse output
2 modules
DIN rail
70
EN 50470-1-3, EN 62053-23-31
Operating features
Connectivity
to single-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active and reactive energy
n° 2
Supply
Rated control supply voltage Un
VAC
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max.) Pv
VA (W)
Overload capability
Voltage Un
continuous
V
momentary (1 s)
V
Current Imax
continuous
A
momentary (10 ms)
A
Display (readouts)
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 7-digit
tariffs 1-2
kWh
+ display import or export (arrow)
overflow
kWh
Reactive energy: 1 display, 7-digit
tariffs 1-2
kvarh
+ display import or export (arrow)
overflow
kvarh
Instantaneous active power: 1 display, 3-digit
W, kW or MW
Instantaneous reactive power: 1 display, 3-digit
var, kvar or Mvar
Instantaneous tariff measurement
1 display, 1-digit
Display period refresh
s
Measuring accuracy
at 23 ±1°C, referred to nominal values
Active energy and power acc.to EN 50470-3
%
Reactive energy and power
acc.to EN 62053-23
%
Measuring input
Type of connection
phase/N
Operating range voltage phase/N
V
Current Iref
A
Current Imin
A
Operating range current (Ist ... Imax)
direct connection
A
Frequency
Hz
Input waveform
Starting current for energy measurement (Ist)
mA
181
2
yes
T1 and T2
230
184 ... 276
50
≤8 (0.6)
276
300
80
2400
7 (1 decimal)
6.00 x 3
000000.0 ... 999999.9
999999.9 ... 000000.0
000000.0 ... 999999.9
999999.9 ... 000000.0
000 ... 999
000 ... 999
1
T1 or T2
1
B
2
direct
184 ... 276
15
0.75
0.025 ... 80
50
sinusoidal
25
Measuring Instruments
EME1P80
EME1P80MID
direct connection 80 A
Pulse output S0
Pulse output
Pulse quantity
Pulse duration
Required voltage
Permissible current
Permissible current
acc.to EN 62053-31
for active and reactive energy T1 and T2
yes
Imp/kWh
1000
ms
30 ±2 ms
min. (max.)
VAC (DC)
5 ... 230 ±5% (5 ... 300)
pulse ON (max. 230 V AC/DC)
mA
90
impuls OFF (leakage currrent max. 230 V AC/DC)
µA
1
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
Safety acc. to EN 50470-1
Indoor meter
Degree of pollution
Operational voltage
V
AC voltage test (EN 50470-3, 7.2)
kV
Impulse voltage test
1.2/50 µs-kV
Protection class (EN 50470)
class
Housing material flame resistance
UL 94
class
Safety-sealing between upper and lower housing part
Adaptor for Communication
Plug-and-play technology
LAN Interface (TCP/IP) Ethernet 802.3
EMECLAN
Modbus RTU, Ascii
RS-485 3 wires
EMECMODB
M-Bus
RS-485 2 wires
EMECMBUS
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Type cage pulse output blade for slotted screw
mm
Terminal capacity main current paths
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Terminal capacity pulse outlet
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Mechanical environment
Electromagnetic environment
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity (not condensation)
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Degree protectionhousing when mounted in front (terminal)
-
1000
yes
2
300
4
6
II
V0
no
yes
•
10/100 Mbps
up to 19.200 bps
up to 9.600 bps
PZ2
0.8 x 3.5
1.5 (35)
1.5 (35)
0.14 (2.5)
0.14 (1.5)
M1
E2
-10 ... +55
-25 ... +70
≤80
±0.075
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
Dimensions (mm)
Connection diagram
A Miniature Circuit Breaker of 80A
is recommended.
182
Measuring Instruments
Energy-meters single-phase 125 A, EME
• Digital active and reactive energy meter with measurement of active and
reactive instantaneous power, by IR side set up communication - 2 tariffs
• Active energy-meters for single-phase alternating current with either 2,
8 digits digital counters. These meters have 2 S0 output generating pulses
for remote processing of the energy active and reactive measurements for
2 tariffs.
• Green backlighted LCD
• For direct connection 125 A
• 8 digits for energy values indication
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Accuracy class 2 for reactive energy and power according to EN 62053-23
• Most attractive operating range current (Ist ... Imax) for direct connection
125 A = 0.020 ... 125 A
• The standard versions are designed to be combined with the communication module
• Energy register zero setting (not for MID types)
• Energy register for import and export
• Instantaneous power active and reactive display
• Sealable terminal covers
• 3 DIN modules wide (52 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME1P125 EME1P125MID
direct connection 125 A
EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31
DIN 43880
EN 60715
DIN
35 mm
mm
active energy
reactive energy - pulse output
3 modules
DIN rail
70
EN 50470-1-3, EN 62053-23-31
Operating features
Connectivity
to single-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active and reactive energy
n° 2
Supply
Rated control supply voltage Un
VAC
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max.) Pv
VA (W)
Overload capability
Voltage Un
continuous
V
momentary (1 s)
V
Current Imax
continuous
A
momentary (10 ms)
A
Display (readouts)
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 8 digit
tariffs 2
Wh
+ display import or export (arrow)
overflow
MWh
Reactive energy: 1 display, 8 digit
tariffs 2
varh
+ display import or export (arrow)
overflow
Mvarh
Instantaneous active power: 1 display, 3-digit
W, kW or MW
Instantaneous reactive power: 1 display, 3-digit
var, kvar or Mvar
Instantaneous tariff measurement
1 display, 1-digit
Display period refresh
s
Measuring accuracy
at 23 ±1°C, referred to nominal values
Active energy and power acc.to EN 50470-3
%
Reactive energy and power
acc.to EN 62053-23
%
Measuring input
Type of connection
phase/N
Operating range voltage phase/N
V
Current Iref
A
Current Imin
A
Operating range current (Ist ... Imax)
direct connection
A
Frequency
Hz
Input waveform
Starting current for energy measurement (Ist)
mA
183
2
yes
T1 and T2
230
184 ... 276
50
≤8 (0.6)
276
300
125
3750
8 (2 decimal)
6.00 x 3
0.01
999999.99
0.01
999999.99
000 ... 999
000 ... 999
1
T1 or T2
1
B
2
direct
184 ... 276
5
0.25
0.020 ... 125
50
sinusoidal
20
Measuring Instruments
EME1P125 EME1P125MID
direct connection 125 A
Pulse output S0
Pulse output
Pulse quantity
Pulse duration
Required voltage
Permissible current
Permissible current
acc.to EN 62053-31
for active and reactive energy T1 and T2
yes
Imp/kWh
1000
ms
30 ±2 ms
min. (max.)
VAC (DC)
5 ... 230 ±5% (5 ... 300)
pulse ON (max. 230 V AC/DC)
mA
90
impuls OFF (leakage currrent max. 230 V AC/DC)
µA
1
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
Safety acc. to EN 50470-1
Indoor meter
Degree of pollution
Operational voltage
V
AC voltage test (EN 50470-3, 7.2)
kV
Impulse voltage test
1.2/50 µs-kV
Protection class (EN 50470)
class
Housing material flame resistance
UL 94
class
Safety-sealing between upper and lower housing part
Adaptor for Communication
Plug-and-play technology
LAN Interface (TCP/IP) Ethernet 802.3
EMECLAN
Modbus RTU, Ascii
RS-485 3 wires
EMECMODB
M-Bus
RS-485 2 wires
EMECMBUS
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Type cage pulse output blade for slotted screw
mm
Terminal capacity main current paths
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Terminal capacity pulse outlet
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Mechanical environment
Electromagnetic environment
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity (not condensation)
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Degree protectionhousing when mounted in front (terminal)
-
1000
yes
2
300
4
6
II
V0
no
yes
•
10/100 Mbps
up to 19.200 bps
up to 9.600 bps
PZ2
0.8 x 3.5
1.5 (50)
1.5 (50)
1 (4)
1 (2.5)
M1
E2
-10 ... +55
-25 ... +70
≤80
±0.075
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
Dimensions (mm)
Connection diagram
A Miniature Circuit Breaker of 125A
is recommended.
184
Measuring Instruments
Energy-meters three-phase, transformer 5 A, direct 80 A, EME
• Digital active and reactive energy-meter with measurement of active and
reactive instantaneous power, by IR side set up communication - 2 tariffs 2 S0 (MID types: displays only active power).
• Active energy-meters for three-phase alternating current with either 2,
8 digits digital counters. These meters have 2 S0 output generating pulses
for remote processing of the instantaneous energy active and reactive
measurements for 2 tariffs.
• Green backlighted LCD
• For direct connection 80 A, or for transformer .../5 A
• For transformer primary current of 5 A to 10.000/5 A. Input is in 5 A increments
• 8 digits - 8 display for energy values indication
• Detection of connection errors (phase transposition)
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Accuracy class 2 for reactive energy and power according to EN 62053-23
• Most attractive operating range current (Ist ... Imax), for direct connection 80
A = 0.015 ... 80 A, for connection by CT .../5 A = 0.003 ... 5 A
• The standard versions are designed to be combined with the communication module
• Energy register zero setting (not for MID types)
• Energy register for import and export
• Instantaneous power active and reactive display (MID types: only active
power)
• Sealable terminal covers
• 4 DIN modules wide (72 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME3P80
EME3P80MID EME3PCT
EME3PCTMID
direct connection 80 A
CT connection till 10.000/5 A
EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31
DIN 43880
EN 60715
active energy
pulse output
DIN
35 mm
mm
-
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
2-4
4
yes
yes
T1 and T2
T1 and T2
230
184 ... 276
50
≤8 (0.6)
230
184 ... 276
50
≤8 (0.6)
480
800
276
460
80
2400
480
800
276
460
6
120
-
PHASE Err
8 (2 decimal)
6.00 x 3
PHASE Err
8 (2 decimal)
6.00 x 3
0.01
0.01
999999.99
999999.99
0.01
0.01
999999.99
000 ... 999
000 ... 999
999999.99
000 ... 999
000 ... 999
T1 or T2
1
T1 or T2
5 ... 10.000
1
B
2
B
2
Operating features
Connectivity
to single/three-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active and reactive energy
n° 2
Supply
VAC
Rated control supply voltage Un
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max. for phase) Pv
VA (W)
Overload capability
Voltage Un
continuous; phase/phase V
1 second: phase/phase
V
continuous; phase/N
V
1 second: phase/N
V
continuous
A
Current Imax
momentary (0,5 s)
A
momentary (10 ms)
A
Display (readouts)
Connection errors and phase out
discernible from phase-sequence indication
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 8 digit
tariffs 2
Wh
+ display import or export (arrow)
overflow
MWh
Reactive energy: 1 display, 8-digit
tariffs 2
varh
+ display import or export (arrow)
overflow
Mvarh
Instantaneous active power: 1 display, 3-digit
W, kW or MW
Instantaneous reactive power: 1 display, 3-digit
var, kvar or Mvar
Instantaneous tariff measurement
1 display, 1-digit
Transformer primary current
A
Display period refresh
s
Measuring accuracy
Active energy and power acc.to EN 50470-3
class 1
Reactive energy and power acc.to EN 62053-23
class 2
185
Measuring Instruments
Measuring input
Type of connection
Voltage Un
phase/phase
V
phase/N
V
Operating range voltage phase/phase
V
phase/N
V
Current Iref
A
A
Current In
Current Imin
A
Operating range current (Ist ... Imax)
direct connection
A
transformer connection (CT) A
Transformer current
primary current of the transformer
A
smallest input step adjustment
A
Frequency
Hz
Input waveform
Starting current for energy measurement (Ist)
mA
Pulse output SO
acc.to EN 62053-31
Pulse output
for act. and react. energy T1 and T2
Quantity pulse output
for direct connection 80 A Imp/kWh
depending on the transf. factor.
Imp/kWh
Pulse duration
ms
Required voltage
min. (max.)
VAC (DC)
Permissible current
pulse ON (max. 230 V AC/DC)
mA
Permissible current pulse OFF (leakage current max. 230 V AC/DC)
µA
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
Safety acc. to EN 50470-1
Indoor meter
Degree of pollution
Operational voltage
V
AC voltage test (EN 50470-3, 7.2)
kV
Impulse voltage test
1.2/50 µs-kV
Protection class (EN 50470)
class
Housing material flame resistance
UL 94
class
Safety-sealing between upper and lower housing part
Adaptor for Communication
Plug-and-play technology
LAN (TCP/IP) interface Ethernet 802.3
EMECLAN
Modbus RTU, Ascii interface
RS-485 - 3 wires
EMECMODB
M-Bus interface
RS-485 - 2 wires
EMECMBUS
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Type cage pulse output blade for slotted screw
mm
Terminal capacity main current paths
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Terminal capacity pulse outlet
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
186
EME3P80
EME3P80MID
direct connection 80 A
EME3PCT
EME3PCTMID
CT connection till 10.000/5 A
direct
400
230
319 ... 480
184 ... 276
5
0.25
transformer .../5 A
400
230
319 ... 480
184 ... 276
5
0.05
0.015 ... 80
-
0.003 ... 6
50
sinusoidal
15
5 ...10.000
in 5 A steps
5
50
sinusoidal
3
yes
500
yes
-
30 ±2
5 ... 230 ±5% (5 ... 300)
100-10-1
30 ±2
5 ... 230 ±5% (5 ... 300)
90
90
1
1
1000
10.000
yes
2
300
4
6
II
yes
2
300
4
6
II
V0
V0
yes
no
no
yes
•
10/100 Mbps
•
10/100 Mbps
up to 19.200 bps
up to 9.600 bps
up to 19.200 bps
up to 9.600 bps
PZ2
0.8 x 3.5
PZ1
0.8 x 3.5
1.5 (35)
1 (4)
1.5 (35)
1 (4)
1 (4)
1 (4)
1 (2.5)
1 (4)
Measuring Instruments
Environmental conditions
Mechanical environment
Electromagnetic environment
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity (not condensation)
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Degree protectionhousing when mounted in front (terminal)
-
EME3P80
EME3P80MID
direct connection 80 A
EME3PCT
EME3PCTMID
CT connection till 10.000/5 A
M1
E2
-10 ... +55
-25 ... +70
≤80
M1
E2
-10 ... +55
-25 ... +70
≤80
±0.075
±0.075
IP51*)/IP20
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
Direct connection 80 A
Dimensions (mm)
Connection diagrams
A Miniature Circuit Breaker of 80A
is recommended.
Wire N needs to be connected to
the meter.
187
Measuring Instruments
Connection through CT .../5 A till 10.000/5 A
Dimensions (mm)
Connection diagrams
Wire N needs to be connected to the meter.
Instructions for the connection of transformer counters
A Miniature Circuit Breaker of 6A is recommended. Current
transformers must not be operated with open terminals since
dangerous high voltages might occur which may result in personal injuries
and property damage. In addition to this, the transformers are
exposed to thermal overload.
188
Measuring Instruments
Energy-meters three-phase 125 A, EME
• Digital active and reactive energy-meter with measurement of active and
reactive instantaneous power, by IR side set up communication - 2 tariffs 2 S0 (MID types: displays only active power).
• Active energy-meters for three-phase alternating current with either 2,
8 digits digital counters. These meters have 2 S0 output generating pulses
for remote processing of the instantaneous energy active and reactive
measurements for 2 tariffs.
• Green backlighted LCD
• For direct connection 125 A
• 8 digits - 8 display for energy values indication
• Detection of connection errors (phase transposition)
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Accuracy class 2 for reactive energy and power according to EN 62053-23
• Most attractive operating range current (Ist ... Imax) for direct connection
125 A = 0.020 ... 125 A
• The standard versions are designed to be combined with the communication module
• Energy register zero setting (not for MID types)
• Energy register for import and export
• Instantaneous power active and reactive display (MID types: only active
power)
• Sealable terminal covers
• 6 DIN modules wide (108 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME3P125 EME3P125MID
direct connection 125 A
EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31
DIN 43880
EN 60715
DIN
35 mm
mm
active energy
reactive energy - pulse output
6 modules
DIN rail
70
EN 50470-1-3
EN 62053-23-31
Operating features
Connectivity
to single/three-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active and reactive energy
n° 2
Supply
Rated control supply voltage Un
VAC
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max.) Pv
VA (W)
Overload capability
Voltage Un
continuous; phase/phase V
1 second: phase/phase
V
continuous; phase/N
V
1 second: phase/N
V
continuous
A
Current Imax
momentary (10 ms)
A
Display (readouts)
Connection errors and phase out
discernible from phase-sequence indication
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 8 digit
tariffs 2
Wh
+ display import or export (arrow)
overflow
MWh
Reactive energy: 1 display, 8 digit
tariffs 2
varh
+ display import or export (arrow)
overflow
Mvarh
Instantaneous active power: 1 display, 3-digit
W, kW or MW
Instantaneous reactive power: 1 display, 3-digit
var, kvar or Mvar
Instantaneous tariff measurement
1 display, 1-digit
Display period refresh
s
Measuring accuracy
Active energy and power acc.to EN 50470-3
%
Reactive energy and power
acc.to EN 62053-23
%
Measuring input
Type of connection
Voltage Un
phase/phase
V
phase/N
V
Operating range voltage
phase/phase
V
phase/N
V
189
2-4
yes
T1 and T2
230
184 ... 276
50
≤8 (0.6)
480
800
276
300
125
3750
PHASE Err
8 (2 decimal)
6.00 x 3
0.01
999999.99
0.01
999999.99
000 ... 999
000 ... 999
1
T1 or T2
1
B
2
direct
400
230
319 ... 480
184 ... 276
Measuring Instruments
EME3P125 EME3P125MID
direct connection 125 A
Measuring input
A
5
Current Iref
Current Imin
A
0.25
Operating range current (Ist ... Imax)
direct connection
A
0.020 ... 125
Frequency
Hz
50 ±2%
Input waveform
sinusoidal
Starting current for energy measurement (Ist)
mA
20
Pulse output S0
acc.to EN 62053-31
Pulse output
for active and reactive energy T1 and T2
yes
Quantity pulse output
Imp/kWh
500
Pulse duration
ms
30 ±2 ms
Required voltage
min. (max.)
VAC (DC)
5 ... 230 ±5% (5 ... 300)
Permissible current
pulse ON (max. 230 V AC/DC)
mA
90
Permissible current
impuls OFF (leakage currrent max. 230 V AC/DC)
µA
1
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
1000
Safety acc. to EN 50470-1
Indoor meter
yes
Degree of pollution
2
Operational voltage
V
300
AC voltage test (EN 50470-3, 7.2)
kV
4
Impulse voltage test
1.2/50 µs-kV
6
Protection class (EN 50470)
class
II
Housing material flame resistance
UL 94
class
V0
Safety-sealing between upper and lower housing part
no
yes
Adaptor for Communication
Plug-and-play technology
•
LAN (TCP/IP) interface Ethernet 802.3
EMECLAN
10/100 Mbps
Modbus RTU, Ascii interface
RS-485 - 3 wires
EMECMODB
up to 19.200 bps
M-Bus interface
RS-485 - 2 wires
ENECMBUS
up to 9.600 bps
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
PZ2
Type cage pulse output blade for slotted screw
mm
0.8 x 3.5
Terminal capacity main current paths
1.5 (50)
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
1.5 (50)
Terminal capacity pulse outlet
solid wire min. (max.)
mm2
1 (4)
stranded wire with sleeve min. (max.)
mm2
1 (2.5)
Environmental conditions
Mechanical environment
M1
Electromagnetic environment
E2
Operating temperature
°C
-10 ... +55
Limit temperature of transportation and storage
°C
-25 ... +70
Relative humidity (not condensation)
%
≤80
Vibrations
50 Hz sinusoidal vibration amplitude
mm
±0.075
Degree protectionhousing when mounted in front (terminal)
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
190
Measuring Instruments
Dimensions (mm)
Connection diagrams
A Miniature Circuit Breaker of
125A is recommended.
Wire N needs to be connected to the meter.
191
Measuring Instruments
LAN-TCP/IP interface EMECLAN
• Additional communication modules for Energy-meter, Network analyzer
and Power-meters
• Additional module for LAN-TCP/IP connection for energy, power, V, I, cosϕ,
frequency
• Data transfer speed LAN limited Mbit/s 100
•
•
•
•
HW interface RJ 45 connector
SW protocol TCP/IP
Suitable for both single-phase and three-phase energy meters
1 DIN module wide (18 mm)
Technical Data
EMECLAN
IEC 60950, EN 61000-6-2, EN 61000-6-3 and EN 61000-4-2
Data in compliance with
General characteristics
Housing
DIN 43880
DIN
Mounting
EN 60715
35 mm
Depth
mm
Power supply
Auxiliary voltage rating Un
VAC
Auxiliary power rating
W
Auxiliary voltage range
VAC
Frequency rating
Hz
Frequency range
Hz
Operating features
System start
LAN Server data addressing
Data transfer speed
LAN limited
Mbit/s
User interface for setup and management
Web browser
Suitable for both single-phase and three-phase energy meters
LAN Interface
HW interface
SW protocol
Interface to measuring instrument
HW interface
optical IR
n°
SW protocol
Safety acc. to IEC 60950
Degree pollution
Overvoltage category
Working voltage
V
Clearance
mm
Creepage distance
mm
Test voltage
impulse (1,2/50 µs) peak value
on AC power supply
kV
50 Hz 1 min
kV
Housing material flame resistance
UL 94
class
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Terminal capacity
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Protection class
acc.to IEC 60950
Degree of protection
housing when mounted in front
1 module
DIN rail
70
230
≤1.5
0.80 ... 1.20 x Un
50/60
45 ... 65
automatic at connection of auxiliary power
by means of it IP address
≤100
W3C HTML 4.01 compliant
yes
RJ 45 connector
TCP/IP
2 (Tx, Rx)
proprietary
2
II
300
≥4
≥4
4
4
V0
PZ0
0.15 (2.5)
0.15 (4)
0 ... +55
-25 ... +70
≤80
±0.25
II
IP20
Dimensions (mm)
192
Measuring Instruments
M-Bus interface EMECMBUS
• Additional communication modules for Energy-meter, Network analyzer
and Power-meters
• Additional module for M-Bus connection for energy, power, V, I, cosϕ, frequency
• M-Bus according to EN1434
• Suitable for both single-phase and three-phase energy meters
• 1 DIN module wide (18 mm)
Technical Data
EMECMBUS
EN 13757-1-2-3, IEC 60950, EN 61000-6-2, EN 61000-6-3 and
EN 61000-4-2
Data in compliance with
General characteristics
Housing
DIN 43880
DIN
Mounting
EN 60715
35 mm
Depth
mm
Power supply
Power supply
Operating features
Suitable for both single-phase and three-phase energy meters
M-bus interface
HW interface
SW protocol
Baudrate
Baud
Interface to measuring instrument
HW interface
optical IR
n°
SW protocol
Safety acc. to IEC 60950
Degree pollution
Overvoltage category
Working voltage
V
Clearance
in equipment
mm
on PCB (not coated)
mm
Creepage distance
mm
Test voltage
impulse (1,2/50 µs)
peak value
kV
50 Hz 1 min
kV
Housing material flame resistance
UL 94
class
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Terminal capacity
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Protection class
acc.to IEC 60950
Degree of protection
housing when mounted in front
1 module
DIN rail
70
through bus connection
yes
2 screw clamps
M-Bus according to EN1434
300-9600
2 (Tx, Rx)
proprietary
2
II
24 ... 36
≥1.5
≥1.5
≥2.1
2.5
1.35
V0
PZ0
0.15 (2.5)
0.15 (4)
0 ... +55
-25 ... +70
≤80
±0.25
II
IP20
Dimensions (mm)
193
Measuring Instruments
Modbus interface RTU and Ascii EMECMODB
• Additional communication modules for Energy-meter, Network analyzer
and Power-meters
• Additional module for Modbus RTU and Ascii connection for energy,
power, V, I, cosϕ, frequency
• Protocols Modbus Ascii - Modbus RTU
• Suitable for both single-phase and three-phase energy meters
• 1 DIN module wide (18 mm)
Technical Data
Data in compliance with
General characteristics
Housing
DIN 43880
DIN
Mounting
EN 60715
35 mm
Depth
mm
Power supply
Auxiliary voltage rating Un
VAC
Auxiliary power rating
W
Auxiliary voltage range
VAC
Frequency rating
Hz
Frequency range
Hz
Operating features
Protocol
selectable by software
Suitable for both single-phase and three-phase energy meters
Modbus interface
HW interface
RS-485
terminals n°
Input resistance
UL (kΩ)
Termination resistance
Ω
SW protocol
SW selectable
Data transfer speed
SW selectable
baud
Parity
Addressing
Interface to measuring instrument
HW interface
optical IR
n°
SW protocol
Safety acc. to IEC 60950
Degree pollution
Overvoltage category
Working voltage
V
Clearance
mm
Creepage distance
mm
Test voltage
impulse (1,2/50 µs) peak value
on AC power supply
kV
on telecommunication network
kV
50 Hz 1 min
kV
Housing material flame resistance
UL 94
class
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Terminal capacity
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Protection class
acc.to IEC 60950
Degree of protection
housing when mounted in front
Dimensions (mm)
194
EMECMODB
IEC 60950, EN 61000-6-2, EN 61000-6-3 and EN 61000-4-2
1 module
DIN rail
70
230
≤10
0.80 ... 1.20 x Un
50/60
45 ... 65
Modbus RTU or Ascii
yes
3 (+/-, cable shield)
1 (12)
80
Modbus Ascii - Modbus RTU
≤38.400 - default 19200
none/even - default: none
1 to 247
2 (Tx, Rx)
proprietary
2
II
300
≥4
≥4
2.5
1.5
2.5
V0
PZ0
0.15 (2.5)
0.15 (4)
0 ... +55
-25 ... +70
≤80
±0.25
II
IP20
Measuring Instruments
BASIC Energy-meters three-phase, transformer 5 A, EME
• Active energy-meters for three-phase alternating current with either 2,
9 digits digital counters. These meters have 1 S0 output generating pulses
for remote processing of the instantaneous energy active measurements
for 2 tariffs.
• Three-phase digital active energy-meter with connection by CT .../5 A, up to
10.000/5 A - 0.05-5 (6) A - 2 tariffs - 2 S0
• For transformer .../5 A
• For transformer primary current of 5 A to 10.000/5 A. Input is in 5 A increments
• 9 digits - 4 display for energy values indication
• Detection of connection errors (phase transposition and phase missing)
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Most attractive operating range current (Ist ... Imax), for connection by
CT .../5 A = 0.003 ... 5 A
• Energy register zero setting (not for MID types)
• Energy register for import and export
• Sealable terminal covers
• 4 DIN modules wide (72 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME3PCTB EME3PCTBMID
CT connection till 10.000/5 A
EN 50470-1, EN 50470-3 and EN 62053-31
DIN 43880
EN 60715
active energy
pulse output
DIN
35 mm
mm
-
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
Operating features
Connectivity
to three-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active energy
n° 2
Supply
Rated control supply voltage Un
VAC
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max. for phase) Pv
VA (W)
Overload capability
Voltage Un
continuous; phase/phase V
1 second: phase/phase
V
continuous; phase/N
V
1 second: phase/N
V
Current Imax
continuous
A
momentary (0,5 s)
A
momentary (10 ms)
A
Display (readouts)
Connection errors and phase out
discernible from phase-sequence indication
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 9 digit - 2 tariffs
min. measuring energy
kWh
+ display import or export (arrow)
max. measuring overflow kWh
Instantaneous tariff measurement
1 display, 1-digit
Transformer primary current
A
Display period refresh
s
Measuring accuracy
Active energy
acc.to EN 50470-3
class 1
Measuring input
Type of connection
Voltage Un
phase/phase
V
phase/N
V
Operating range voltage phase/phase
V
phase/N
V
Current Iref
A
A
Current In
Current Imin
A
Operating range current (Ist ... Imax)
direct connection
A
transformer connection (CT) A
195
4
yes
T1 and T2
230
184 ... 276
50
≤8 (0.6)
480
800
276
300
6
120
-
PHASE Err
9 (2 decimal)
6.00 x 3
0.01
9999999.99
T1 or T2
5 ... 10.000
1
B
transformer .../5 A
400
230
319 ... 480
184 ... 276
5
0.05
0.003 ... 6
Measuring Instruments
EME3PCTB EME3PCTBMID
CT connection till 10.000/5 A
Measuring input
Transformer current
primary current of the transformer
A
5 ...10.000
smallest input step adjustment
in 5 A steps
A
5
Frequency
Hz
50
Input waveform
sinusoidal
Starting current for energy measurement (Ist)
mA
3
Pulse output S0
acc.to EN 62053-31
Pulse output
for active and reactive energy T1 and T2
yes
Quantity pulse output
for direct connection 63 A Imp/kWh
depending on the transf. factor
Imp/kWh
100-10-1
Pulse duration
ms
30 ±2 ms
Required voltage
min. (max.)
VAC (DC)
5 ... 230 ±5% (5 ... 300)
Permissible current
pulse ON (max. 230 V AC/DC)
mA
90
Permissible current
impuls OFF (leakage currrent max. 230 V AC/DC)
µA
1
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
10.000
Safety acc. to EN 50470-1
Indoor meter
yes
Degree of pollution
2
Operational voltage
V
300
AC voltage test (EN 50470-3, 7.2)
kV
4
Impulse voltage test
1.2/50 µs-kV
6
Protection class (EN 50470)
class
II
Housing material flame resistance
UL 94
class
V0
Safety-sealing between upper and lower housing part
no
yes
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
PZ1
Type cage pulse output blade for slotted screw
mm
0.8 x 3.5
Terminal capacity main current paths
1 (4)
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
1 (4)
Terminal capacity pulse outlet
1 (4)
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
1 (4)
Environmental conditions
Mechanical environment
M1
Electromagnetic environment
E2
Operating temperature
°C
-10 ... +55
Limit temperature of transportation and storage
°C
-25 ... +70
Relative humidity (not condensation)
%
≤80
Vibrations
50 Hz sinusoidal vibration amplitude
mm
±0.075
Degree protectionhousing when mounted in front (terminal)
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
196
Measuring Instruments
Connection through CT .../5 A till 10.000/5 A
Connection diagrams
Dimensions (mm)
Wire N needs to be connected to the meter.
Instructions for the connection of transformer counters
A Miniature Circuit Breaker of 6A is recommended.
Current transformers must not be operated with open terminals
since dangerous high voltages might occur which
may result in personal injuries and property damage. In addition to this, the transformers are exposed to thermal overload.
197
Measuring Instruments
BASIC Energy-meters three-phase, direct 63 A, EME
• Active energy-meters for three-phase alternating current with either 2,
9 digits digital counters. These meters have 2 S0 output generating pulses
for remote processing of the instantaneous energy active measurements
for 2 tariffs.
• Three-phase digital active energy-meter with direct connection 0.25-5 (63) A
- 2 tariffs - 2 S0
• For direct connection 63 A
• 9 digits - display for 4 energy values indication
• Detection of connection errors (phase transposition and phase missing)
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Most attractive operating range current (Ist ... Imax), for direct connection
63 A = 0.015 ... 63 A
• Energy register zero setting (not for MID types)
• Energy register for import and export
• Sealable terminal covers
• 4 DIN modules wide (72 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME3P63B
EME3P63BMID
direct connection 63 A
direct connection 63 A
EN 50470-1, EN 50470-3 and EN 62053-31
DIN 43880
EN 60715
active energy
pulse output
DIN
35 mm
mm
-
Operating features
Connectivity
to three-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active energy
n° 2
Supply
Rated control supply voltage Un
VAC
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max. for phase) Pv
VA (W)
Overload capability
Voltage Un
continuous; phase/phase V
1 second: phase/phase
V
continuous; phase/N
V
1 second: phase/N
V
Current Imax
continuous
A
momentary (0,5 s)
A
momentary (10 ms)
A
Display (readouts)
Connection errors and phase out
discernible from phase-sequence indication
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 9 digit - 2 tariffs
min. measuring energy
kWh
+ display import or export (arrow)
max. measuring overflow kWh
Instantaneous tariff measurement
1 display, 1-digit
Transformer primary current
A
Display period refresh
s
Measuring accuracy
Active energy
acc.to EN 50470-3
class 1
Measuring input
Type of connection
Voltage Un
phase/phase
V
phase/N
V
Operating range voltage phase/phase
V
phase/N
V
Current Iref
A
A
Current In
Current Imin
A
Operating range current (Ist ... Imax)
direct connection
A
transformer connection (CT) A
198
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
4
4
yes
T1 and T2
yes
T1 and T2
230
184 ... 276
50
≤8 (0.6)
230
184 ... 276
50
≤8 (0.6)
480
800
276
300
63
1900
480
800
276
300
63
1900
PHASE Err
9 (2 decimal)
6.00 x 3
PHASE Err
9 (2 decimal)
6.00 x 3
0.01
0.01
9999999.99
9999999.99
T1 or T2
1
T1 or T2
1
B
B
direct
400
230
319 ... 480
184 ... 276
5
0.25
direct
400
230
319 ... 480
184 ... 276
5
0.25
0.015 ... 80
-
0.015 ... 80
-
Measuring Instruments
EME3P63B
direct connection 63 A
EME3P63BMID
direct connection 63 A
Measuring input
Transformer current
primary current of the transformer
A
smallest input step adjustment
A
Frequency
Hz
50
Input waveform
sinusoidal
Starting current for energy measurement (Ist)
mA
15
Pulse output S0
acc.to EN 62053-31
Pulse output
for active and reactive energy T1 and T2
yes
Quantity pulse output
for direct connection 63 A Imp/kWh
500
depending on the transf. factor
Imp/kWh
Pulse duration
ms
30 ±2 ms
Required voltage
min. (max.)
VAC (DC)
5 ... 230 ±5% (5 ... 300)
Permissible current
pulse ON (max. 230 V AC/DC)
mA
90
Permissible current
impuls OFF (leakage currrent max. 230 V AC/DC)
µA
1
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
1000
Safety acc. to EN 50470-1
Indoor meter
yes
Degree of pollution
2
Operational voltage
V
300
AC voltage test (EN 50470-3, 7.2)
kV
4
Impulse voltage test
1.2/50 µs-kV
6
Protection class (EN 50470)
class
II
Housing material flame resistance
UL 94
class
V0
Safety-sealing between upper and lower housing part
yes
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
PZ2
Type cage pulse output blade for slotted screw
mm
0.8 x 3.5
Terminal capacity main current paths
solid wire min. (max.)
mm2
1.5 (35)
stranded wire with sleeve min. (max.)
mm2
1.5 (35)
Terminal capacity pulse outlet
1 (4)
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
1 (2.5)
Environmental conditions
Mechanical environment
M1
Electromagnetic environment
E2
Operating temperature
°C
-10 ... +55
Limit temperature of transportation and storage
°C
-25 ... +70
Relative humidity (not condensation)
%
≤80
Vibrations
50 Hz sinusoidal vibration amplitude
mm
±0.075
Degree protectionhousing when mounted in front (terminal)
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
199
50
sinusoidal
15
yes
500
30 ±2 ms
5 ... 230 ±5% (5 ... 300)
90
1
1000
yes
2
300
4
6
II
V0
yes
PZ2
0.8 x 3.5
1.5 (35)
1.5 (35)
1 (4)
1 (2.5)
M1
E2
-10 ... +55
-25 ... +70
≤80
±0.075
IP51*)/IP20
Measuring Instruments
Direct connection 63 A
Dimensions (mm)
Connection diagrams
A Miniature Circuit Breaker of 63A
is recommended.
Wire N needs to be connected to
the meter.
200
Measuring Instruments
BASIC Energy-meters three-phase, 63 A, EME
• Digital active energy meter with partial active energy counter resettable
and inbuilt communication Modbus RTU- 2 tariffs
• Three-phase digital active energy-meter with direct connection 0.25-5
(63) A, and inbuilt communication Modbus RTU - 2 tariffs
• For direct connection 63 A
• 9 digits for 8 energy indication values
• Detection of connection errors (phase transposition and phase missing)
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Most attractive operating range current (Ist ... Imax), for direct connection
63 A = 0.015 ... 63 A
• Energy register zero setting (not for MID types)
• Energy register “Partial” zero setting also for MID types
• Sealable terminal covers
• Energy register for delivery and supply
• 4 DIN modules wide (72 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME3P63BMODBUS
EME3P63BMODBUSMID
direct connection 63 A
direct connection 63 A
EN 50470-1, EN 50470-3 and EN 62053-31
DIN 43880
EN 60715
active energy
pulse output
DIN
35 mm
mm
-
Operating features
Connectivity
to three-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active energy
n° 2
Supply
Rated control supply voltage Un
VAC
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max. for phase) Pv
VA (W)
Overload capability
Voltage Un
continuous; phase/phase V
1 second: phase/phase
V
continuous; phase/N
V
1 second: phase/N
V
Current Imax
continuous
A
momentary (0,5 s)
A
momentary (10 ms)
A
Display (readouts)
Connection errors and phase out
discernible from phase-sequence indication
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 9 digit - 2 tariffs
min. measuring energy
kWh
+ display import or export (arrow)
max. measuring overflow kWh
Instantaneous tariff measurement
1 display, 1-digit
Transformer primary current
A
Display period refresh
s
Measuring accuracy
Active energy
acc.to EN 50470-3
class 1
Measuring input
Type of connection
Voltage Un
phase/phase
V
phase/N
V
Operating range voltage phase/phase
V
phase/N
V
A
Current Iref
Current In
A
A
Current Imin
Operating range current (Ist ... Imax)
direct connection
A
transformer connection (CT) A
Transformer current
primary current of the transformer
A
smallest input step adjustment
A
Frequency
Hz
Input waveform
Starting current for energy measurement (Ist)
mA
201
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
4
4
yes
T1 and T2
yes
T1 and T2
230
184 ... 276
50
≤8 (0.6)
230
184 ... 276
50
≤8 (0.6)
480
800
276
300
80
2400
480
800
276
300
80
2400
PHASE Err
9 (2 decimal)
6.00 x 3
PHASE Err
9 (2 decimal)
6.00 x 3
0.01
0.01
9999999.99
9999999.99
T1 or T2
1
T1 or T2
1
B
B
direct
400
230
319 ... 480
184 ... 276
5
0.25
direct
400
230
319 ... 480
184 ... 276
5
0.25
0.015 ... 63
-
0.015 ... 63
-
50
sinusoidal
15
50
sinusoidal
15
Measuring Instruments
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
Safety acc. to EN 50470-1
Indoor meter
Degree of pollution
Operational voltage
V
AC voltage test (EN 50470-3, 7.2)
kV
Impulse voltage test
1.2/50 µs-kV
Protection class (EN 50470)
class
Housing material flame resistance
UL 94
class
Safety-sealing between upper and lower housing part
Embedded communication
Modbus RTU
RS-485 - 3 wires
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Type cage pulse output blade for slotted screw
mm
Terminal capacity main current paths
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Terminal capacity pulse outlet
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Mechanical environment
Electromagnetic environment
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity (not condensation)
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Degree protectionhousing when mounted in front (terminal)
-
EME3P63BMODBUS
direct connection 63 A
EME3P63BMODBUSMID
direct connection 63 A
1000
1000
yes
2
300
4
6
II
yes
2
300
4
6
II
V0
V0
yes
yes
up to 19.200 bps
up to 19.200 bps
PZ2
0.8 x 3.5
PZ2
0.8 x 3.5
1.5 (35)
1.5 (35)
1.5 (35)
1.5 (35)
1 (4)
1 (4)
1 (2.5)
1 (2.5)
M1
E2
-10 ... +55
-25 ... +70
≤80
M1
E2
-10 ... +55
-25 ... +70
≤80
±0.075
±0.075
IP51*)/IP20
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
Dimensions (mm)
Connection diagrams
Wire N needs to be connected to
the meter.
A Miniature Circuit Breaker of 63A
is recommended.
202
Measuring Instruments
BASIC Energy-meters three-phase, direct 80 A, EME
• Active energy-meters for three-phase alternating current with either 2,
9 digits digital counters. These meters have 2 S0 output generating pulses
for remote processing of the instantaneous energy active measurements
for 2 tariffs.
• Three-phase digital active energy-meter with direct connection 0.015 (80) A
- 2 tariffs - 2 S0
• For direct connection 80 A
• 9 digits - display for 4 energy values indication
• Detection of connection errors (phase transposition and phase missing)
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Most attractive operating range current (Ist ... Imax), for direct connection
80 A = 0.015 ... 80 A
• Energy register zero setting (not for MID types)
• Energy register for import and export
• Sealable terminal covers
• 4 DIN modules wide (72 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME3P80BMID
direct connection 80 A
EN 50470-1, EN 50470-3 and EN 62053-31
DIN 43880
EN 60715
active energy
pulse output
DIN
35 mm
mm
-
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
Operating features
Connectivity
to three-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active energy
n° 2
Supply
Rated control supply voltage Un
VAC
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max. for phase) Pv
VA (W)
Overload capability
Voltage Un
continuous; phase/phase V
1 second: phase/phase
V
continuous; phase/N
V
1 second: phase/N
V
Current Imax
continuous
A
momentary (0,5 s)
A
momentary (10 ms)
A
Display (readouts)
Connection errors and phase out
discernible from phase-sequence indication
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 9 digit - 2 tariffs
min. measuring energy
kWh
+ display import or export (arrow)
max. measuring overflow kWh
Instantaneous tariff measurement
1 display, 1-digit
Transformer primary current
A
Display period refresh
s
Measuring accuracy
Active energy
acc.to EN 50470-3
class 1
Measuring input
Type of connection
Voltage Un
phase/phase
V
phase/N
V
Operating range voltage phase/phase
V
phase/N
V
Current Iref
A
A
Current In
Current Imin
A
Operating range current (Ist ... Imax)
direct connection
A
transformer connection (CT) A
203
4
yes
T1 and T2
230
184 ... 276
50
≤8 (0.6)
480
800
276
300
80
2400
PHASE Err
9 (2 decimal)
6.00 x 3
0.01
9999999.99
T1 or T2
1
B
direct
400
230
319 ... 480
184 ... 276
5
0.25
0.015 ... 80
-
Measuring Instruments
EME3P80BMID
direct connection 80 A
Measuring input
Transformer current
primary current of the transformer
A
smallest input step adjustment
A
Frequency
Hz
50
Input waveform
sinusoidal
Starting current for energy measurement (Ist)
mA
15
Pulse output S0
acc.to EN 62053-31
Pulse output
for active and reactive energy T1 and T2
yes
Quantity pulse output
for direct connection 63 A Imp/kWh
500
depending on the transf. factor
Imp/kWh
Pulse duration
ms
30 ±2 ms
Required voltage
min. (max.)
VAC (DC)
5 ... 230 ±5% (5 ... 300)
Permissible current
pulse ON (max. 230 V AC/DC)
mA
90
Permissible current
impuls OFF (leakage currrent max. 230 V AC/DC)
µA
1
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
1000
Safety acc. to EN 50470-1
Indoor meter
yes
Degree of pollution
2
Operational voltage
V
300
AC voltage test (EN 50470-3, 7.2)
kV
4
Impulse voltage test
1.2/50 µs-kV
6
Protection class (EN 50470)
class
II
Housing material flame resistance
UL 94
class
V0
Safety-sealing between upper and lower housing part
yes
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
PZ2
Type cage pulse output blade for slotted screw
mm
0.8 x 3.5
Terminal capacity main current paths
solid wire min. (max.)
mm2
1.5 (35)
stranded wire with sleeve min. (max.)
mm2
1.5 (35)
Terminal capacity pulse outlet
1 (4)
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
1 (2.5)
Environmental conditions
Mechanical environment
M1
Electromagnetic environment
E2
Operating temperature
°C
-10 ... +55
Limit temperature of transportation and storage
°C
-25 ... +70
Relative humidity (not condensation)
%
≤80
Vibrations
50 Hz sinusoidal vibration amplitude
mm
±0.075
Degree protectionhousing when mounted in front (terminal)
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
204
Measuring Instruments
Direct connection 80 A
Dimensions (mm)
Connection diagrams
A Miniature Circuit Breaker of 80A
is recommended.
Wire N needs to be connected to
the meter.
205
Measuring Instruments
BASIC Energy-meters three-phase, 80 A, EME
• Digital active energy meter with partial active energy counter resettable
and inbuilt communication Modbus RTU- 2 tariffs
• Three-phase digital active energy-meter with direct connection 0.015 (80) A,
and inbuilt communication Modbus RTU - 2 tariffs
• For direct connection 80 A
• 9 digits for 8 energy indication values
• Detection of connection errors (phase transposition and phase missing)
• Accuracy class 1 for active energy and power according to EN 50470-3 (B)
• Most attractive operating range current (Ist ... Imax), for direct connection
80 A = 0.015 ... 80 A
• Energy register zero setting (not for MID types)
• Energy register “Partial” zero setting
• Sealable terminal covers
• 4 DIN modules wide (72 mm)
Technical Data
Data in compliance with
General characteristics
Housing
Mounting
Depth
Reference standard
EME3P80BMODBUSMID
direct connection 80 A
EN 50470-1, EN 50470-3 and EN 62053-31
DIN 43880
EN 60715
active energy
pulse output
DIN
35 mm
mm
-
4 modules
DIN rail
70
EN 50470-1-3
EN 62053-31
Operating features
Connectivity
to three-phase network
n° wires
Storage of energy values and configuration
digital display (EEPROM) Display tariffs identifier for active energy
n° 2
Supply
Rated control supply voltage Un
VAC
Operating range voltage
V
Rated frequency fn
Hz
Rated power dissipation (max. for phase) Pv
VA (W)
Overload capability
Voltage Un
continuous; phase/phase V
1 second: phase/phase
V
continuous; phase/N
V
1 second: phase/N
V
Current Imax
continuous
A
momentary (0,5 s)
A
momentary (10 ms)
A
Display (readouts)
Connection errors and phase out
discernible from phase-sequence indication
Display type
LCD
n° digits
digit dimensions
mm x mm
Active energy: 1 display, 9 digit - 2 tariffs
min. measuring energy
kWh
+ display import or export (arrow)
max. measuring overflow kWh
Instantaneous tariff measurement
1 display, 1-digit
Transformer primary current
A
Display period refresh
s
Measuring accuracy
Active energy
acc.to EN 50470-3
class 1
Measuring input
Type of connection
Voltage Un
phase/phase
V
phase/N
V
Operating range voltage phase/phase
V
phase/N
V
A
Current Iref
Current In
A
A
Current Imin
Operating range current (Ist ... Imax)
direct connection
A
transformer connection (CT) A
Transformer current
primary current of the transformer
A
smallest input step adjustment
A
Frequency
Hz
Input waveform
Starting current for energy measurement (Ist)
mA
206
4
yes
T1 and T2
230
184 ... 276
50
≤8 (0.6)
480
800
276
300
80
2400
PHASE Err
9 (2 decimal)
6.00 x 3
0.01
9999999.99
T1 or T2
1
B
direct
400
230
319 ... 480
184 ... 276
5
0.25
0.015 ... 80
50
sinusoidal
15
Measuring Instruments
EME3P80BMODBUSMID
direct connection 80 A
Optical interfaces
Front side (accuracy control)
LED
Imp/kWh
Safety acc. to EN 50470-1
Indoor meter
Degree of pollution
Operational voltage
V
AC voltage test (EN 50470-3, 7.2)
kV
Impulse voltage test
1.2/50 µs-kV
Protection class (EN 50470)
class
Housing material flame resistance
UL 94
class
Safety-sealing between upper and lower housing part
Embedded communication
Modbus RTU
RS-485 - 3 wires
Connection terminals
Type cage main current paths
screw head Z +/POZIDRIV
Type cage pulse output blade for slotted screw
mm
Terminal capacity main current paths
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Terminal capacity pulse outlet
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Mechanical environment
Electromagnetic environment
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity (not condensation)
%
Vibrations
50 Hz sinusoidal vibration amplitude
mm
Degree protectionhousing when mounted in front (terminal)
-
1000
yes
2
300
4
6
II
V0
yes
up to 19.200 bps
PZ2
0.8 x 3.5
1.5 (35)
1.5 (35)
1 (4)
1 (2.5)
M1
E2
-10 ... +55
-25 ... +70
≤80
±0.075
IP51*)/IP20
*) For the installation in a cabinet at least with IP51 protection
Dimensions (mm)
Connection diagrams
Wire N needs to be connected to
the meter.
A Miniature Circuit Breaker of 80A
is recommended.
207
Measuring Instruments
Multimeter, EME3PMMCT5
• The Eaton Multimeter offer an extremely compact multifunction solution
for switchgear and incoming or outgoing feeders in industrial plants and
buildings like offices, hospitals, universities and so on
• Can be connected to three phase networks via current transformers (.../5A
till 10.000/5A)
• Three phase 38 readouts, imported and exported power
• Clear readable LED display that reports all measurements through a userfriendly interface controlled directly from the front panel
• Analysis of the different loads on each phase to identify displacements,
asymmetrical or unbalanced conditions
•
•
•
•
•
Offers a range of different options to combine and assess measured values
Provided with 2 S0 outputs report active and reactive energy
Two different tariffs settled by an external energy counter (Wh and VArh)
With a side IrDA interface for external communication
External communication allows for the transmission of measured values to
a remote energy management system
• 6 modules housing for DIN rail mounting
• User can display continuously five indicated values
Technical Data
Communication link
Connection
Housing DIN modules (wide)
Measuring voltage range
Frequency range
Starting current (Ist)
Reference current (Iref)
Main supply
System connectivity
Display
Display green backlighted
Main terminal
Operating temperature
Pulse output SO
Measuring accurancy
EN 50470-1-3 active energy class 1
EN 62053-23 reactive energy class 2
Voltage
Current
Power factor
Frequency
Active power
Reactive power
Apparent power
Import active energy
Export active energy
Import reactive energy
Export reactive energy
EME3PMMCT5
S0
.../5 A
6
AC 50 ... 276 / 87 ... 480
49 ... 51
3
5
Auxiliary 184 ... 276
2-3-4
LED
YES
4
-10 to +55
2
V
Hz
mA
A
V AC
(n° wires)
(n° digit)
(wire mm2)
°C
(n°)
L1, L2, L3
L1-2, L2-3, L3-1
L1, L2, L3
N
L1, L2, L3
ΣL
L1, L2, L3
ΣL
L1, L2, L3
ΣL
L1, L2, L3
ΣL
L1, L2, L3, ΣL
Tariff 1 and 2
L1, L2, L3, ΣL
Tariff 1 and 2
L1, L2, L3, ΣL
Tariff 1 and 2
L1, L2, L3, ΣL
Tariff 1 and 2
Communication (s)
IR - side: M-Bus, Modbus RTU, KNX, LAN-TCP/IP, SD-Card
B (1%)
2%
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
YES
l = Measured parameters displayed, s = Measured parameters through IR side modules
208
Measuring Instruments
LAN Server Modbus/TCP, EMELSMODBUS
Overview:
The LAN Servers are Plug-and-Play data concentrators for Energy Meter,
Network Analyzer and Power Meter products. The LAN Server allows an easy
and reliable connection of several instruments to a data communication network. It is an innovative product designed to implement fast data communication between a supervisory PC and a set of measurement instruments connected through LAN, WAN or Internet. Instruments may be of different kinds
and are automatically recognized through a unique coding.
LAN Server Modbus/TCP:
This Plug-and-Play product collects the measurement data from different
devices connected via a Modbus serial bus. Data are made available on LAN,
WAN or Intranet through an HTTP interface and are accessible using simultaneously a standard browser or a Modbus/TCP Application.
The LAN Server Modbus/TCP requires an auxiliary at 230 V AC power supply.
Common features
• Worldwide communication with measuring devices
• Hardware connection through RJ45
• TCP/IP data protocol
• HTTP for web server
• FTP for file transfer
• NTP for time synchronization
• Static or DHCP based addressing
• DDNS to maintain a host name, accessible on the internet, without the
need for a static IP
• Plug-and-play technology
• Internet browser user interface, three languages
• Password-protected site access
• Internal memory: 2 Gigabytes available for long period storage
• 4 DIN modules wide (72 mm)
Technical Data
Type
Description
According to norm general EN 61000-6-2-3, EN 61000-4-2
According to norm general
Number of modules
EMELSMODBUS
LAN Server Modbus/TCP
Data Concentrator with Modbus/TCP
YES
EN 60950
4
Power supply
Voltage range
Aux. power rating
Frequency range
230 ±20 %
≤ 10
45 ... 65
V AC
VA
Hz
Operation feature
Memory storage
LAN - HW interface
LAN - SW protocol
LAN - Bandrate
Application level protocols
Interface to instruments
HW interface
SW protocol
Directly connected instruments
S0 impulse input
Safety acc. to IEC 60950
Degree pollution
Overvoltage category
Working voltage
Test voltage impulse
(1,2/50 µs) peak value
50 Hz 1 min
Environmental conditions
Operating temperature
Limit temperature of storage
Relative humidity (non condensing)
Vibrations amplitude at 50 Hz
Protection class
Degree of protection
Internal 2 Gigabyte
RJ 45
TCP/IP
10/100 Mbit/s
HTTP - FTP - modbus/TCP
RS485
3 screw clamps
Modbus RTU and ASCII
31
–
V AC
2
II
... 300
kV
kV
4
4
°C
°C
-10 to 55
-25 to 70
≤ 80%
±0.25
II
IP20
mm
209
Measuring Instruments
Analogue Measuring Instruments Z-MG
•
•
•
•
Analogue ammeters and voltmeters
For measuring single-phase AC voltages and currents
Direct measuring range up to 40 A (AC)
Type Z-MG/AA5-WS with exchangeable dial for transducer operation up to
600 A
• Exchangeable dial (Z-MG/WS...)
• Moving iron measuring unit
• Accessories
Voltmeter changeover switch, see type Z-DSV.
Block Diagram
Technical Data
Z-MG/AA-10
Electrical
Rated voltage Un
Rated current In
Input signal
Rated frequency
Operational frequency
Measuring accuracy class
Measuring range
Power consumption
Exceeding of measuring range
permanently
short time
Rated insulation voltage
Test voltage 50Hz/1min.
Mechanical
Frame size
Device height
Device width
Weight
Mounting
Degree of protection, built-in
Upper and lower terminals
Terminal capacity
Tightening torque of terminal screws
Permitted relative humidity
Perm. ambient temperature range
Flame class acc. to UL 94
Z-MG/AA-40
Z-MG/AA5-WS Z-MG/VA-250
Z-MG/VA-500
–
–
–
10 A
40 A
5A
symmetric, sinusoidal, form factor 1.11
50 Hz
50 Hz
50 Hz
45-65 Hz
45-65 Hz
45-65 Hz
1.5
1.5
1.5
0 - In
0 - In
0 - In
<1,1 VA
<1,1 VA
<1,1 VA
250 V AC
500 V AC
50 Hz
45-65 Hz
1.5
0 - Un
<3 VA
50 Hz
45-65 Hz
1.5
0 - Un
<3 VA
1.2xIn
10xIn/5s
0.6 kV
2 kV
1.2xUn
2xUn/5s
0.6 kV
2 kV
1.2xUn
2xUn/5s
0.6 kV
2 kV
45 mm
89 mm
70 mm
130 g
45 mm
89 mm
70 mm
130 g
IP50
lift terminals
4 mm2
1 Nm
65%
-25 to +50°C
V1
IP50
lift terminals
4 mm2
1 Nm
65%
-25 to +50°C
V1
1.2xIn
10xIn/5s
0.6 kV
2 kV
1.2xIn
10xIn/5s
0.6 kV
2 kV
45 mm
45 mm
45 mm
89 mm
89 mm
89 mm
70 mm
70 mm
70 mm
130 g
130 g
130 g
quick fastening on DIN rail IEC/EN 60715
IP50
IP50
IP50
lift terminals lift terminals lift terminals
4 mm2
8 mm2
4 mm2
1 Nm
1.8 Nm
1 Nm
65%
65%
65%
-25 to +50°C
-25 to +50°C
-25 to +50°C
V1
V1
V1
Dimensions (mm)
210
Measuring Instruments
Digital Measuring Instruments Z-MG
•
•
•
•
•
Digital ammeters and voltmeters
For measuring single-phase AC voltages and currents
7 segment display, green LEDs
LED overload display
Direct measuring range up to 20 A (Z-MG/AD-20)
Via current transformer X/5A (Z-MG/AD-999) display up to 999A.
• Type Z-MG/AD-999:
Possible current transformer ratios 15/5, 20/5, 25/5, 40/5, 60/5, 100/5, 150/5,
200/5, 250/5, 400/5, 600/5, 1000/5 adjustable
• Type Z-MG/VD+AD+S:
has a alarms intervention display - blinking message “AL”
• Accessories: Voltmeter changeover switch, see type Z-DSV.
Connection diagram
Z-MG/VD+AD
A,V
230V~
14
15
12
20
Technical Data
Z-MG/AD-20
Z-MG/AD-999
Z-MG/VD-600
Electrical
Rated voltage Un
Rated current In
Auxiliary voltage
Power consumption auxiliary voltage
Input signal wave form
Rated frequency
Operational frequency
Measuring accuracy
Resolution
Number of measuring operations per second
Measuring range
Power consumption
Voltage input
Current input
Input impedance
Exceeding of measuring range
permanently
short time
Rated insulation voltage
Test voltage 50Hz/1min.
Contact (alarms) 2 pcs.
Type
Set point
Hysteresis
Delay
Relay state
Contacts range
Mechanical
Frame size
Device height
Device width
Maximum display reading
Height of figures
Weight
Mounting
Degree of protection, built-in
Upper and lower terminals
Terminal capacity
Tightening torque of terminal screws
Permitted relative humidity
Perm. ambient temperature range
Flame class acc. to UL 94
45 mm
45 mm
45 mm
89.5 mm
89.5 mm
89.5 mm
71.2 mm
71.2 mm
71.2 mm
999
999
999
14 mm
14 mm
14 mm
300 g
300 g
300 g
quick fastening on DIN rail IEC/EN 60715
IP50
IP50
IP50
lift terminals lift terminals lift terminals
4 mm2
4 mm2
4 mm2
0.6 Nm
0.6 Nm
0.6 Nm
95%
95%
95%
-10°C to +55°C -10°C to +55°C -10°C to +55°C
V1
V1
V1
Dimensions (mm)
–
–
600 V AC
20 A
5A
–
230V, 50Hz
230V, 50Hz
230V, 50Hz
< 4.5 VA
< 4.5 VA
< 4.5 VA
symmetric, sinusoidal, form factor 1.11
50 Hz
50 Hz
50 Hz
45-65 Hz
45-65 Hz
45-65 Hz
±1% +1 digit
±1% +1 digit
±1% +1 digit
1 digit
1 digit
1 digit
3
3
3
0 - In
0 - In
0 - Un
–
Z-MG/VD+AD
Z-MG/VD+AD+S
500 V AC
5A
230V, 50Hz
< 2.5 VA
500 V AC
5A
230V, 50Hz
< 2.5 VA
50 Hz
47-63 Hz
±1% +1 digit
1V/0.01-10A
0.67
0-600V/0,1-6A
50 Hz
47-63 Hz
±1% +1 digit
1V/0.01-10A
0.67
0-600V/0,1-6A
–
–
<1.1 VA
–
–
<1.1 VA
>1MΩ
<0.1VA
–
–
<0.1VA
<0.6VA
–
2xIn
2.5xIn/5s
0.66 kV
2 kV
–
–
–
–
–
–
–
2xIn
10xIn/5s
0.66 kV
2 kV
–
–
–
–
–
–
–
1.1xUn
–
0.66 kV
2 kV
–
–
–
–
–
–
–
1.2xUn/1.2xIn
2xIn/5s
0.66 kV
3 kV
–
–
–
–
–
–
–
1.2xUn/1.2xIn
2xIn/5s
0.66 kV
3 kV
programmable
min. and/or max.
0-120%
0-set point
0-60s (1s steps)
energised/de-energ.
5A/250VAC
45 mm
89.5 mm
71.2 mm
999
14 mm
250 g
45 mm
89.5 mm
71.2 mm
999
14 mm
270 g
IP50
lift terminals
4 mm2
0.6 Nm
20-80%
-5°C to +55°C
V1
IP50
lift terminals
4 mm2
0.6 Nm
20-80%
-5°C to +55°C
V1
<0.6VA
Measuring range - resolution
Z-MG/VD+AD
Z-MG/VD+AD+S
Range
Display
Resolution
Range
Display
Resolution
Range
Display
Resolution
Range
Display
Resolution
211
10A
10.0
15A
15.0
20A 25A
20.0 25.0
100A 120A 150A 160A 200A 250A
100 120 150 160 200 250
1kA 1,2kA 1,5kA 1,6kA 2kA 2,5kA
1.00 1.20 1.50 1.60 2.00 2.50
5A
5.00
10mA
30A 40A 50A 60A 70A 75A
30.0 40.0 50.0 60.0 70.0 75.0
100mA
300A 400A 500A 600A 700A 750A
300 400 500 600 700 750
1A
3kA 4kA 5kA 6kA 7kA 7,5kA
3.00 4.00 5.00 6.00 7.00 7.50
10A
80A
80.0
800A
800
8kA
8.00
Measuring Instruments
Voltmeter EMV600 - Ammeter EMA20
• Digital measuring instruments offer greater readout immediacy for the
value displayed. They also offer the advantage of having no moving parts
which are subject to wear over the long term, an issue which can affect the
precision and reliability of the instrument.
• Voltmeter AC
• Ammeter AC
• 2 DIN modules wide (36 mm)
Technical Data
Data in compliance with
General characteristics
Housing
DIN 43880
Mounting
EN 60715
Depth
Reference standard
Power supply
Voltage
Operating range voltage
Frequency rating
Operating range frequency
Power rating
Overload capability
Voltage Un
continuous
momentary (1 s)
continuous
Current Ib/In
momentary (1 s)
Display (readouts)
Voltage
3 digits h = 10 mm
voltages >600 V
voltages <12 V
Current
3 digits h = 10 mm
Voltmeter
Ammeter
EMV600
EMA20
EN 61010-1, EN 61000-6-2, EN 61000-6-3
DIN
35 mm
mm
-
2 modules
DIN rail
70
DIN 43751-1-2
2 modules
DIN rail
70
DIN 43751-1-2
VAC
VAC
Hz
Hz
VA
230
0.90 ... 1.15
50
45 ... 65
2
230
0.90 ... 1.15
50
45 ... 65
2
V
V
A
A
1.2 x voltage rating
1.3 x voltage rating
-
1.1 x current rating
10 x current rating
V
A
12 ... 600
HHH
---
0.4 ... 20 (a)
0.1 ... 5 (b) (CT operat.)
-
HHH
4
--4
±1 ±1 digit
±0.03
± 0.5 ±1 digit
±0.03
direct
direct (a)(b < 5 A)
with CT .../5 A (b)
20 (a) 5 (b)
0.4 ... 20 (a)
currents >10 A - 20 A/5 A (connection CT)
A
currents <0.1 A - 0.2 A - 0.4 A (connection CT)
A
Readout refresh rate
readout/s
Measuring accuracy
at 23 ±1°C referred to nominal values
Voltage
%
Current
%
Temperature (deviating)
% for °C
Measuring input
Connectivity
Voltage Un
Measurement range
Current Ib/In
Measurement range
Frequency rating
Measurement range
Input waveform
Safety acc. to EN 61010-1
Degree pollution
Overvoltage category
Working voltage
Material group
Clearance
Creepage distance
voltage
current
frequency
V
V
A
A
600
12 ... 600
0.2 ... 10 (b)
Hz
Hz
-
50
45 ... 65
synus. symmetric
(0.1 ... 5) x transformer ratio (b)
50
45 ... 65
synus. symmetric
2
II
300
II
≥3.0
≥4.3
2
II
600
II
≥1.5
≥2.1
≥3.0
≥1.5
4.0
2.2
2.5
1.35
V0
V0
V
mm
inside the equipment
mm
on printed wiring boards (not coated)
mm
Test voltage
impulse (1,2/50 µs) peak value
kV
50 Hz 1 min
kV
Housing material flame resistance
UL 94
class
212
Measuring Instruments
Connection terminals
Type cage
Terminal capacity
screw head Z +/POZIDRIV
solid wire min. (max.)
mm2
stranded wire with sleeve min. (max.)
mm2
Environmental conditions
Operating temperature
°C
Limit temperature of transportation and storage
°C
Relative humidity
%
Vibrations (sinusoidal) 50 Hz sinusoidal vibration amplitude
mm
Protection class
acc.to EN 61010-1
Degree of protection
housing when mounted (terminal)
Dimensions (mm)
Voltmeter
EMV600
Ammeter
EMA20
PZ1
1 (6)
PZ1
1 (6)
1 (6)
1 (6)
0 ... +55
-25 ... +70
≤80
0 ... +55
-25 ... +70
≤80
±0.25
II
IP52 (IP20)
±0.25
II
IP52 (IP20)
Connection diagrams
213
Measuring Instruments
Accessories for Measuring Instruments
Current Transformer for Cable Z-MG/WAK, Current Transformer for Busbar Z-MG/WAS,
• Transform high currents to standard measuring currents
• Current transformers help to cut costs when installing and connecting busbar system
• Recommended from 40 A upward
• Accuracy classes
Class 0.5: for accurate measurement and calibrated kWh-meters
Class 1: for general measurement and non-calibrated kWh-meters
Class 3: for coarse measurement, relays and for protection
• When winding several turns of the primary cable around the current transformer, you will receive half the primary current per turn while power and
class remain unchanged.
Connection diagram
Technical Data
Electrical
Max. service voltage
Secondary current
Rated frequency
Cable diameter
Busbar cross section
Primary nominal current IpN 40 A
50 A
60 A
80 A
100 A
150 A
200 A
250 A
300 A
400 A
500 A
600 A
800 A
1000 A
Connections
Nominal thermic short-time current Ith
Nominal dynamic short circuit current Idyn
Permanent overload
Insulation class (IEC 85)
Test voltage 50Hz/1min.
Mechanical
Mounting
Degree of protection
Secondary connection
Permitted relative humidity
Perm. ambient temperature range
Max. temperature of busbars
Z-MG/WAK
Z-MG/WAS
720 V
5A
50-60 Hz
21 mm
–
Class
3
3
3
3
720 V
5A
50-60 Hz
23 mm, 30 mm
30 x 10 mm, 40 x 10 mm, 50 x 12 mm
Class
P [VA]
P [VA]
1.3
1.5
1.5
2
1
1.5
1
3
1
3
0.5
2
0.5
2
0.5
3
0.5
10
0.5
10
0.5
10
0.5
10
P1 (K) primary input, P2 (L) primary output, s1 (k) secondary input, s2 (l) secondary output
60 x IpN for 1 s
60 x IpN for 1 s
2.5 x Ith for 1 s
2.5 x Ith for 1 s
1.2 x IpN
1.2 x IpN
E
E
6 kV
6 kV
quick fastening on DIN rail IEC/EN 60715,
wall mounting,
directly onto the cable or onto busbar
IP30
IP30
plug-in terminals 6.3 mm
plug-in terminals 6.3 mm
80%
80%
-20 to +50°C
-20 to +50°C
–
70°C
Dimensions (mm)
214
Measuring Instruments
Operating Hours Counter BSZ
• According to DIN 61010
• Hours counter for gathering operating time data of machines and systems
and determining operating costs, maintenance intervals, warranty and
working times.
Connection diagram
Technical Data
Electrical
Rated voltage
Rated frequency
Current consumption
Accuracy
Own consumption
Mechanical
Frame size
Device height
Device width
Weight
Zero position
Operation indicator
Counting range
Height of figures
Colour of figures
Mounting
Degree of protection, built-in
Lower terminals
Terminal capacity
Tightening torque of terminal screws
Temperature range
BSZ/230
BSZ/24
230 V AC ±10%
50 Hz
10 mA
line frequency-dependent
1 VA
24 V AC ±10%
50 Hz
10 mA
line frequency-dependent
1 VA
45 mm
45 mm
85 mm
85 mm
35 mm
35 mm
75 g
75 g
no
no
no
no
99999,99 h
99999,99 h
3.5 mm
3.5 mm
white on black
white on black
decimals red
decimals red
quick fastening on DIN rail IEC/EN 60715
IP40
IP40
screw terminals
10 mm2
10 mm2
1.2 Nm
1.2 Nm
-25 to +55°C
-25 to +55°C
Dimensions (mm)
215
Measuring Instruments
Operating Hours Counter ASOHC230
• The operating hours counter registers the operating hours to an accuracy
of two decimals (hundredths of a second).
• Power supply for terminals 1 and 3 of the electronic counter is required to
enable the device to continuously display the measured values. If terminal
3 is supplied with voltage (at DC “+“), the counting process will get started.
• In case of a power failure, the counting result will be saved for an indefinite
period of time (EEPROM). Once power is back again, counting will be continued from the value that has been saved before.
• The 7-digit LCD display can be reset electrically or manually.
• Time counters are used for a reliable collection of production and service
hours, which allows an accurate planning and monitoring of production
processes, maintenance cycles and warranty periods.
Connection diagram
Technical Data
ASOHC230
DIN VDE 0435-110, DIN EN 60255-6, UL 863
UL 863, UL File No. E300537, CSA C22.2 No. 6 and 55
230
0,9 ... 1,1
50
Standards
Approvals
Rated control supply voltage Uc
VAC
Working range
at 50/60 Hz
x Uc
Rated frequency
Hz
Rated power loss Pv
VA
<1
Type of operation
counting of
Display
Cyclometer register
h
Terminals
±Screws (Philips)
Terminal capacity
rigid
mm2
flexible with wire end sleeve, min.
mm2
Allowed range of ambient temperature
°C
Degree of protection
acc. to DIN EN 60529
Protection class
acc. to DIN EN 61140 / VDE 0140
Allowed range of air humidity
%
hours
00000,00
1
1,5
0,75
-10 ... +70
IP20, with conductors connected
II
<80
Dimensions (mm)
216
Measuring Instruments
Pulse Counter Z-IMZ
• According to DIN 61010
Connection diagram
Z-IMZ
Technical Data
Z-IMZ/230
Z-IMZ/24
Electrical
Rated voltage
Rated frequency
Current consumption
Accuracy
Counting frequency
Pulse duration / interval
Duty
Own consumption
230 V AC ±10%
50 Hz
8 mA
–
max. 10 pulse/s
10 ms
100%
1.84 VA
24 V AC ±10%
50 Hz
10 mA
–
max. 10 pulse/s
10 ms
100%
0.24 VA
Mechanical
Frame size
Device height
Device width
Weight
Zero position
Operation indicator
Counting range
Height of figures
Colour of figures
Mounting
Degree of protection, built-in
Lower terminals
Terminal capacity
Tightening torque of terminal screws
Temperature range
45 mm
45 mm
90 mm
90 mm
35 mm
35 mm
60 g
60 g
no
no
no
no
9999999 pulses
9999999 pulses
4 mm
4 mm
white on black
white on black
quick fastening on DIN rail IEC/EN 60715
IP65
IP65
screw terminals
0.14-4 mm2
0.14-4 mm2
0.8 Nm
0.8 Nm
-10 to +70°C
-10 to +70°C
Dimensions (mm)
217
Measuring Instruments
Pulse Counter ASPC230
• The pulse counter sums up the number of pulses, e.g. how many times a
device is switched on.
• Power supply for terminals 1 and 3 of the electronic counter is required to
enable the device to continuously display the measured values. If terminal
3 is supplied with voltage (at DC “+“), the counting process will get started.
Supplying terminal 4 with voltage for a moment (at DC “+“) will reset the
counter.
• In case of a power failure, the counting result will be saved for an indefinite
period of time (EEPROM). Once power is back again, counting will be continued from the value that has been saved before.
• The 7-digit LCD display can be reset electrically or manually.
• Pulse counters are used for a reliable collection of production and service
hours, which allows an accurate planning and monitoring of production
processes, maintenance cycles and warranty periods.
• Pulse counting is used for general quantity counting, registration of the
switch-on frequency, and for the collection of switch-on cycles or production quantities in systems and machines.
Connection diagram
Technical Data
Standards
Approvals
Rated control supply voltage Uc
Working range
at 50/60 Hz
Rated frequency
Rated power loss Pv
VA
Type of operation
counting of
Display
Cyclometer register
LCD Display
Frequency of counting
Pulse duration
Resetting
ASPC230
DIN VDE 0435-110, DIN EN 60255-6, UL 863
UL 863, UL File No. E300537, CSA C22.2 No. 6 and 55
230
0,9 ... 1,1
50/60
VAC
x Uc
Hz
<1
-
pulses
0000000
--10
50
--1
1,5
h
Hz
ms
electrical
mechanical
Terminals
±Screws (Philips)
Terminal capacity
rigid
mm2
flexible with wire end sleeve, min.
mm2
Allowed range of ambient temperature
°C
Degree of protection
acc. to DIN EN 60529
Protection class
acc. to DIN EN 61140 / VDE 0140
Allowed range of air humidity
%
0,75
-10 ... +70
IP20, with conductors connected
II
<80
Dimensions (mm)
218