OWNER’S MANUAL Thank you for choosing Providence. In order to take full advantage of the product’s features and performance, please read this manual thoroughly and keep it in a safe place for future reference. ■Features • Compact dimensions (180 mm wide x 60 mm deep) • 70 mm footswitch spacing for easy operation • Three DC9V outputs (180 mA max.) • DC9V output overload warning indicator • Bright indicator LEDs with high-visibility lenses • Effect loop switches feature Single Contact True Bypass circuitry ensuring that the signal only passes through one contact per switch in bypass mode for maximum reliability and sound quality. ■Functions The RX-L1 provides three series-connected effect loops. Effect units connected to the effect loops can be selected and combined as required via footswitches while maintaining optimum signal quality at all times. ■Controls and Connections ①L1 (Loop 1 Switch) Turns Loop 1 ON or OFF. When the loop is ON the corresponding indicator will light and the signal will be routed through the effect unit connected to the SND-1 and RTN-1 jacks. ②L2 (Loop 2 Switch) Turns Loop 2 ON or OFF. When the loop is ON the corresponding indicator will light and the signal will be routed through the effect unit connected to the SND-2 and RTN-2 jacks. ③L3 (Loop 3 Switch) Turns Loop 3 ON or OFF. When the loop is ON the corresponding indicator will light and the signal will be routed through the effect unit connected to the SND-3 and RTN-3 jacks. ④DC9V OVERLOAD (DC9V Overload Indicator) This warning indicator will light when the total current load on the three DC9V outputs exceeds the maximum supply capacity of 180 milliamps.. ⑤IN (Input) The output from the guitar, bass, or other instrument used is connected to this input jack. ⑥SND-1〜SND-3 (Send 1〜Send 3) These are the send jacks for the effect loops. Each send jack should be connected to the input jack of the corresponding effect unit. ■Connection example ⑦RTN-1〜RTN-3 (Return 1〜Return 3) These are the return jacks from corresponding effect loops. The output from each effect unit should be connected to the corresponding return jack. ⑧OUT (Output) This is the final output from the effect chain. The OUT jack should be connected to the input of the following amplifier or processing device. ⑨DC9V OUT (DC9V Output) DC9V output connectors. Three DC9V outputs with a total supply capacity of 180 milliamps are provided. ⑩POWER (DC9V Input) The AC adaptor used to power the unit should be connected here. ■About the RX Series DC9V Outputs ■Specifications • Power Consumption: DC9V, approx. 30 mA (all LEDs ON) • Dimensions (W x D x H): 180 x 60 x 32 front/40 rear mm, not including protrusions • Weight: approx. 450 grams ■Precautions The RX series routing boxes include three DC9V outputs that can be used to power compatible effect units. The total current supply capacity of the three outputs is 180 milliamps. If the 180 milliamp supply capacity is exceeded the DC9V OVERLOAD indicator will light to warn that a voltage drop and overheating may occur. Do not continue to use the device if the OVERLOAD indicator lights. Refer to the manuals that came with the effect units being used for information on their power consumption. Each DC9V output also includes an independent filter that prevents power line noise from entering the signal path. The main power supply circuit additionally features a short protection circuit that prevents damage to the power supply if the DC9V output is accidentally shorted. • The footswitches will operate and the audio signal will be routed accordingly even if the power supply (AC adaptor) is not connected, but the LED indicators will not light and no power will be supplied to the DC9V outputs. • Do not insert/remove plugs into/from the unit’s input or output jacks while connected to an amplifier or speaker system that is powered ON. Doing so can cause noise spikes that might damage the speakers. • If the unit malfunctions, cease operation immediately and contact the dealer from which the unit was purchased or the manufacturer. *Specification and appearance are subject to change without notice. PPD0837-02 Rev 1.1 OWNER’S MANUAL Thank you for choosing Providence. In order to take full advantage of the product’s features and performance, please read this manual thoroughly and keep it in a safe place for future reference. ■Features • Compact dimensions (180 mm wide x 60 mm deep) • 70 mm footswitch spacing for easy operation • Three DC9V outputs (180 mA max.) • DC9V output overload warning indicator • Bright indicator LEDs with high-visibility lenses • Effect loop switches feature Single Contact True Bypass circuitry ensuring that the signal only passes through one contact per switch in bypass mode for maximum reliability and sound quality. ■Functions The RX-S1 provides two series-connected effect loops. Effect units connected to the effect loops can be selected and combined as required via footswitches while maintaining optimum signal quality at all times. An A/B output select circuit is provided following the effect loops, allowing the device’s output to be switched between two different amplifiers, an amplifier and a tuner, or simply muted as required. ■Controls and Connections ①L1 (Loop 1 Switch) Turns Loop 1 ON or OFF. When the loop is ON the corresponding indicator will light and the signal will be routed through the effect unit connected to the SND-1 and RTN-1 jacks. ②L2 (Loop 2 Switch) Turns Loop 2 ON or OFF. When the loop is ON the corresponding indicator will light and the signal will be routed through the effect unit connected to the SND-2 and RTN-2 jacks. ③A/B (A/B Switch) Routes the output signal to either the A or B output. The indicator lights when the A output is selected. When the indicator is not lit the B output is selected. ④DC9V OVERLOAD (DC9V Overload Indicator) This warning indicator will light when the total current load on the three DC9V outputs exceeds the maximum supply capacity of 180 milliamps.. ⑤IN (Input) The output from the guitar, bass, or other instrument used is connected to this input jack. ⑥SND-1〜SND-2 (Send 1〜Send 2) These are the send jacks for the effect loops. Each send jack should be connected to the input jack of the corresponding effect unit. ■Connection example ⑦RTN-1〜RTN-2 (Return 1〜Return 2) These are the return jacks from corresponding effect loops. The output from each effect unit should be connected to the corresponding return jack. ⑧A-OUT (A Output) The signal is output via this jack when the indicator above the A/B Switch is lit. This output jack should be connected to the input of the following amplifier or other device. ⑨B-OUT (B Output) The signal is output via this jack when the indicator above the A/B Switch is lit. This output jack should be connected to the input of the following amplifier or other device. ⑩DC9V OUT (DC9V Output) DC9V output connectors. Three DC9V outputs with a total supply capacity of 180 milliamps are provided. ■Specifications • Power Consumption: DC9V, approx. 30 mA (all LEDs ON) • Dimensions (W x D x H): 180 x 60 x 32 front/40 rear mm, not including protrusions • Weight: approx. 450 grams ■Precautions • The footswitches will operate and the audio signal will be routed accordingly even if the power supply (AC adaptor) is not connected, but the LED indicators will not light and no power will be supplied to the DC9V outputs. • Do not insert/remove plugs into/from the unit’s input or output jacks while connected to an amplifier or speaker system that is powered ON. Doing so can cause noise spikes that might damage the speakers. • If the unit malfunctions, cease operation immediately and contact the dealer from which the unit was purchased or the manufacturer. *Specification and appearance are subject to change without notice. PPD0837-02 ⑪POWER (DC9V Input) The AC adaptor used to power the unit should be connected here. ■About the RX Series DC9V Outputs The RX series routing boxes include three DC9V outputs that can be used to power compatible effect units. The total current supply capacity of the three outputs is 180 milliamps. If the 180 milliamp supply capacity is exceeded the DC9V OVERLOAD indicator will light to warn that a voltage drop and overheating may occur. Do not continue to use the device if the OVERLOAD indicator lights. Refer to the manuals that came with the effect units being used for information on their power consumption. Each DC9V output also includes an independent filter that prevents power line noise from entering the signal path. The main power supply circuit additionally features a short protection circuit that prevents damage to the power supply if the DC9V output is accidentally shorted. Rev 1.1