products manual - Providence

advertisement
OWNER’S MANUAL
Thank you for choosing Providence. In order to take full advantage of the product’s features and performance, please read this
manual thoroughly and keep it in a safe place for future reference.
■Features
• Compact dimensions (180 mm wide x 60 mm deep)
• 70 mm footswitch spacing for easy operation
• Three DC9V outputs (180 mA max.)
• DC9V output overload warning indicator
• Bright indicator LEDs with high-visibility lenses
• Effect loop switches feature Single Contact True Bypass circuitry ensuring that the signal only passes through one contact
per switch in bypass mode for maximum reliability and sound
quality.
■Functions
The RX-L1 provides three series-connected effect loops. Effect units connected to the effect loops can be selected and combined as required via
footswitches while maintaining optimum signal quality at all times.
■Controls and Connections
①L1 (Loop 1 Switch)
Turns Loop 1 ON or OFF. When the loop is ON the corresponding indicator will
light and the signal will be routed through the effect unit connected to the
SND-1 and RTN-1 jacks.
②L2 (Loop 2 Switch)
Turns Loop 2 ON or OFF. When the loop is ON the corresponding indicator will
light and the signal will be routed through the effect unit connected to the
SND-2 and RTN-2 jacks.
③L3 (Loop 3 Switch)
Turns Loop 3 ON or OFF. When the loop is ON the corresponding indicator will
light and the signal will be routed through the effect unit connected to the
SND-3 and RTN-3 jacks.
④DC9V OVERLOAD (DC9V Overload Indicator)
This warning indicator will light when the total current load on the three DC9V
outputs exceeds the maximum supply capacity of 180 milliamps..
⑤IN (Input)
The output from the guitar, bass, or other instrument used is connected to this
input jack.
⑥SND-1〜SND-3 (Send 1〜Send 3)
These are the send jacks for the effect loops. Each send jack should be connected to the input jack of the corresponding effect unit.
■Connection example
⑦RTN-1〜RTN-3 (Return 1〜Return 3)
These are the return jacks from corresponding effect loops. The output from
each effect unit should be connected to the corresponding return jack.
⑧OUT (Output)
This is the final output from the effect chain. The OUT jack should be connected to the input of the following amplifier or processing device.
⑨DC9V OUT (DC9V Output)
DC9V output connectors. Three DC9V outputs with a total supply capacity of
180 milliamps are provided.
⑩POWER (DC9V Input)
The AC adaptor used to power the unit should be connected here.
■About the RX Series DC9V Outputs
■Specifications
• Power Consumption: DC9V, approx. 30 mA (all LEDs ON)
• Dimensions (W x D x H): 180 x 60 x 32 front/40 rear mm, not including
protrusions
• Weight: approx. 450 grams
■Precautions
The RX series routing boxes include three DC9V outputs that can be used to
power compatible effect units. The total current supply capacity of the three
outputs is 180 milliamps. If the 180 milliamp supply capacity is exceeded the
DC9V OVERLOAD indicator will light to warn that a voltage drop and overheating may occur. Do not continue to use the device if the OVERLOAD indicator
lights. Refer to the manuals that came with the effect units being used for information on their power consumption.
Each DC9V output also includes an independent filter that prevents power line
noise from entering the signal path. The main power supply circuit additionally
features a short protection circuit that prevents damage to the power supply if
the DC9V output is accidentally shorted.
• The footswitches will operate and the audio signal will be routed
accordingly even if the power supply (AC adaptor) is not connected, but
the LED indicators will not light and no power will be supplied to the
DC9V outputs.
• Do not insert/remove plugs into/from the unit’s input or output jacks
while connected to an amplifier or speaker system that is powered ON.
Doing so can cause noise spikes that might damage the speakers.
• If the unit malfunctions, cease operation immediately and contact the
dealer from which the unit was purchased or the manufacturer.
*Specification and appearance are subject to change without notice.
PPD0837-02
Rev 1.1
OWNER’S MANUAL
Thank you for choosing Providence. In order to take full advantage of the product’s features and performance, please read this
manual thoroughly and keep it in a safe place for future reference.
■Features
• Compact dimensions (180 mm wide x 60 mm deep)
• 70 mm footswitch spacing for easy operation
• Three DC9V outputs (180 mA max.)
• DC9V output overload warning indicator
• Bright indicator LEDs with high-visibility lenses
• Effect loop switches feature Single Contact True Bypass circuitry ensuring that the signal only passes through one contact
per switch in bypass mode for maximum reliability and sound
quality.
■Functions
The RX-S1 provides two series-connected effect loops. Effect units connected to the effect loops can be selected and combined as required via
footswitches while maintaining optimum signal quality at all times. An A/B output select circuit is provided following the effect loops, allowing the
device’s output to be switched between two different amplifiers, an amplifier and a tuner, or simply muted as required.
■Controls and Connections
①L1 (Loop 1 Switch)
Turns Loop 1 ON or OFF. When the loop is ON the corresponding indicator will
light and the signal will be routed through the effect unit connected to the
SND-1 and RTN-1 jacks.
②L2 (Loop 2 Switch)
Turns Loop 2 ON or OFF. When the loop is ON the corresponding indicator will
light and the signal will be routed through the effect unit connected to the
SND-2 and RTN-2 jacks.
③A/B (A/B Switch)
Routes the output signal to either the A or B output. The indicator lights when
the A output is selected. When the indicator is not lit the B output is selected.
④DC9V OVERLOAD (DC9V Overload Indicator)
This warning indicator will light when the total current load on the three DC9V
outputs exceeds the maximum supply capacity of 180 milliamps..
⑤IN (Input)
The output from the guitar, bass, or other instrument used is connected to this
input jack.
⑥SND-1〜SND-2 (Send 1〜Send 2)
These are the send jacks for the effect loops. Each send jack should be connected to the input jack of the corresponding effect unit.
■Connection example
⑦RTN-1〜RTN-2 (Return 1〜Return 2)
These are the return jacks from corresponding effect loops. The output from
each effect unit should be connected to the corresponding return jack.
⑧A-OUT (A Output)
The signal is output via this jack when the indicator above the A/B Switch is lit.
This output jack should be connected to the input of the following amplifier or
other device.
⑨B-OUT (B Output)
The signal is output via this jack when the indicator above the A/B Switch is lit.
This output jack should be connected to the input of the following amplifier or
other device.
⑩DC9V OUT (DC9V Output)
DC9V output connectors. Three DC9V outputs with a total supply capacity of
180 milliamps are provided.
■Specifications
• Power Consumption: DC9V, approx. 30 mA (all LEDs ON)
• Dimensions (W x D x H): 180 x 60 x 32 front/40 rear mm, not including
protrusions
• Weight: approx. 450 grams
■Precautions
• The footswitches will operate and the audio signal will be routed
accordingly even if the power supply (AC adaptor) is not connected, but
the LED indicators will not light and no power will be supplied to the
DC9V outputs.
• Do not insert/remove plugs into/from the unit’s input or output jacks
while connected to an amplifier or speaker system that is powered ON.
Doing so can cause noise spikes that might damage the speakers.
• If the unit malfunctions, cease operation immediately and contact the
dealer from which the unit was purchased or the manufacturer.
*Specification and appearance are subject to change without notice.
PPD0837-02
⑪POWER (DC9V Input)
The AC adaptor used to power the unit should be connected here.
■About the RX Series DC9V Outputs
The RX series routing boxes include three DC9V outputs that can be used to
power compatible effect units. The total current supply capacity of the three
outputs is 180 milliamps. If the 180 milliamp supply capacity is exceeded the
DC9V OVERLOAD indicator will light to warn that a voltage drop and overheating may occur. Do not continue to use the device if the OVERLOAD indicator
lights. Refer to the manuals that came with the effect units being used for information on their power consumption.
Each DC9V output also includes an independent filter that prevents power line
noise from entering the signal path. The main power supply circuit additionally
features a short protection circuit that prevents damage to the power supply if
the DC9V output is accidentally shorted.
Rev 1.1