Sealed Filter Driers Removes System Contaminants, Acid and Moisture Available with solid copper solder connections or steel flare connections F E A T U R E S Suitable for HCFC, HFC and CO2 refrigerants Maximum Working Pressure of 45 Barg Unique design with two solid core options henrytech.co.uk DESIGNED FOR PERFORMANCE HENRY TECHNOLOGIES S EA L E D F I LT E R D RI E RS The function of a filter drier is to remove system contaminants, acid and moisture. Applications Sealed Filter Driers are designed to protect refrigeration and airconditioning systems by removing moisture, acids and solid particles. Sealed Filter Driers are for use in the liquid line of the system. The range is suitable for use with HCFC, HFC and CO2 refrigerants (see core data). Main Features • Available with solid copper solder connections or steel flare connections • Solid core for drying/acid removal • Filter pad and mesh to remove solid particles • Suitable for HCFC, HFC and CO2 refrigerants Technical Specification Allowable operating temperature = -40°C to +100°C Allowable operating pressure = 0 to 45 barg Cores Selection Guidelines ‘M’ Core The user should select the appropriate core based on refrigerant and oil types (see note). The model should then be selected based on the required drying and liquid capacities. • 100% Molecular Sieve • High drying capacity • Suitable for HCFC, HFC and CO2 refrigerants. Note: Cores with Activated Alumina (type ’A’) are not recommended for use with oils containing additives. ‘A’ Core • 80% Molecular Sieve and 20% Activated Alumina • Absorbs moisture and acid in the system • Not suitable for oils containing additives. • Suitable for HCFC, HFC and CO2 refrigerants Installation – Main Issues 1. Install the filter drier upstream of the liquid line controls to give maximum protection. Locate upstream of moisture indicator so that drying effectiveness can be measured. 2. Ensure the indicated flow direction is complied with. Materials of Construction AC &R C OMPO NENTS PRO DUCTS The shell is constructed from carbon steel and powder coated for corrosion resistance. Connections are available as either copper ODS or steel flare type. Each core is constructed from a moulded composite of desiccant materials bonded to provide very high mechanical strength, micronic filtration and high moisture absorption. The ‘A’ core also provides acid removal. 2 2 1 Inlet flare connection 5 Solid core 2 Shell 6 Filter pad 3 Spring 7 Filter mesh 4 Perforated plate 8 Outlet flare connection 3 2 1 8 4 7 6 4 5 SEALED FILTER DRIERS S A E F LA R E M O D E L S Part No Conn Size (inch) Shell Diameter (mm) A (mm) ØB (mm) C (mm) Weight (kg) CE Cat SDM/SDA-032 SDM/SDA-033 SDM/SDA-052 SDM/SDA-053 SDM/SDA-082 SDM/SDA-083 SDM/SDA-084 SDM/SDA-162 SDM/SDA-163 SDM/SDA-164 SDM/SDA-165 SDM/SDA-303 SDM/SDA-304 SDM/SDA-305 SDM/SDA-306 SDM/SDA-413 SDM/SDA-414 SDM/SDA-415 SDM/SDA-416 1/4 3/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 5/8 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 46 46 65 65 65 65 65 78 78 78 78 78 78 78 78 92 92 92 92 63 63 72 72 98 98 98 112 112 112 112 185 185 185 185 192 192 192 192 46 46 65 65 65 65 65 78 78 78 78 78 78 78 78 92 92 92 92 110 120 119 129 145 155 163 159 169 177 185 242 250 258 264 249 257 265 271 0.26 0.31 0.40 0.44 0.52 0.55 0.58 0.75 0.79 0.83 0.90 1.24 1.29 1.35 1.37 1.87 1.89 1.94 1.97 SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP CAT I CAT I CAT I CAT I Part No Conn Size (inch) Shell Diameter (mm) A (mm) ØB (mm) C (mm) D (mm) Weight (kg) CE Cat SDM/SDA-032S SDM/SDA-033S SDM/SDA-052S SDM/SDA-053S SDM/SDA-082S SDM/SDA-083S SDM/SDA-084S SDM/SDA-162S SDM/SDA-163S SDM/SDA-164S SDM/SDA-165S SDM/SDA-303S SDM/SDA-304S SDM/SDA-305S SDM/SDA-306S SDM/SDA-413S SDM/SDA-414S SDM/SDA-415S SDM/SDA-416S 1/4 3/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 5/8 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 46 46 65 65 65 65 65 78 78 78 78 78 78 78 78 92 92 92 92 63 63 72 72 98 98 98 112 112 112 112 185 185 185 185 192 192 192 192 46 46 65 65 65 65 65 78 78 78 78 78 78 78 78 92 92 92 92 81 85 90 94 116 120 122 130 134 136 134 207 209 220 209 214 216 214 216 13 13 13 13 13 13 13 13 13 13 13 13 13 13 15 13 13 13 15 0.23 0.26 0.36 0.38 0.48 0.49 0.50 0.76 0.81 0.82 0.90 1.21 1.25 1.27 1.29 1.81 1.82 1.83 1.84 SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP SEP CAT I CAT I CAT I CAT I ODS MODELS Flare Model ODS Model 1 Inlet 2 Outlet 3 SEALED FILTER DRIERS D R Y I N G A N D L I Q U I D C A PA C I T Y TA B L E - ‘ M ’ C O R E Model Details Part No SDM-032/S SDM-033/S SDM-052/S SDM-053/S SDM-082/S SDM-083/S SDM-084/S SDM-162/S SDM-163/S SDM-164/S SDM-165/S SDM-303/S SDM-304/S SDM-305/S SDM-306/S SDM-413/S SDM-414/S SDM-415/S SDM-416/S R22 Conn Size (inch) 1/4 3/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 5/8 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 24°C 4.9 4.9 9.8 9.8 15.8 15.8 15.8 24.6 24.6 24.6 24.6 51.2 51.2 51.2 51.2 76.8 76.8 76.8 76.8 52°C 4.6 4.6 9.1 9.1 14.6 14.6 14.6 22.8 22.8 22.8 22.8 47.4 47.4 47.4 47.4 71.2 71.2 71.2 71.2 Drying Capacity (kg of refrigerant) R134a/R507 R404A 24°C 52°C 24°C 52°C 5.3 5 7.8 4.8 5.3 5 7.8 4.8 10.6 10.1 15.6 9.6 10.6 10.1 15.6 9.6 16.9 16.1 24.9 15.4 16.9 16.1 24.9 15.4 16.9 16.1 24.9 15.4 26.4 25.2 38.9 24.1 26.4 25.2 38.9 24.1 26.4 25.2 38.9 24.1 26.4 25.2 38.9 24.1 55 52.3 81 50 55 52.3 81 50 55 52.3 81 50 55 52.3 81 50 82.4 78.5 121.4 75 82.4 78.5 121.4 75 82.4 78.5 121.4 75 82.4 78.5 121.4 75 Liquid Capacity (kW) R407C/R410A 24°C 52°C 5.3 4.6 5.3 4.6 10.6 9.1 10.6 9.1 17 14.6 17 14.6 17 14.6 26.6 22.8 26.6 22.8 26.6 22.8 26.6 22.8 55.3 47.4 55.3 47.4 55.3 47.4 55.3 47.4 82.9 71.1 82.9 71.1 82.9 71.1 82.9 71.1 R-22 R-134a R-404A R-407C R-410A CO2 6.1 20.8 7.7 19 7.9 21.7 31.1 8.6 23 34.9 34.4 23.2 35.7 43.5 64.3 26.3 41.6 58.3 67.7 5.8 17.7 6.4 17.2 6.6 18.7 26.7 7.2 20.1 30.3 30.1 20.2 31.1 38.2 56 23.2 36.4 50.9 59.1 3.2 10.3 3.5 10.2 3.6 10.5 15.6 3.9 11.1 16.9 16 11 16.8 21.3 30.9 12.7 19.9 27.1 31.4 6.1 20.8 7.7 19 7.9 21.7 31.1 8.6 23 34.9 34.4 23.2 35.7 43.5 64.3 26.3 41.6 58.3 67.7 6.5 22.1 8.2 20.2 8.5 23.1 33.2 9.2 24.5 37.3 36.7 24.7 38.1 46.4 68.5 28 44.4 62.2 72.2 8.9 27.1 9.8 26.3 10.1 28.7 40.8 11 30.8 46.4 46.1 31 47.6 58.4 85.6 35.5 55.6 77.9 90.4 R-22 R-134a R-404A R-407C R-410A CO2 6.1 20.8 7.7 19 7.9 21.7 31.1 8.6 23 34.9 34.4 23.2 35.7 43.5 64.3 26.3 41.6 58.3 67.7 5.8 17.7 6.4 17.2 6.6 18.7 26.7 7.2 20.1 30.3 30.1 20.2 31.1 38.2 56 23.2 36.4 50.9 59.1 3.2 10.3 3.5 10.2 3.6 10.5 15.6 3.9 11.1 16.9 16 11 16.8 21.3 30.9 12.7 19.9 27.1 31.4 6.1 20.8 7.7 19 7.9 21.7 31.1 8.6 23 34.9 34.4 23.2 35.7 43.5 64.3 26.3 41.6 58.3 67.7 6.5 22.1 8.2 20.2 8.5 23.1 33.2 9.2 24.5 37.3 36.7 24.7 38.1 46.4 68.5 28 44.4 62.2 72.2 8.9 27.1 9.8 26.3 10.1 28.7 40.8 11 30.8 46.4 46.1 31 47.6 58.4 85.6 35.5 55.6 77.9 90.4 D R Y I N G A N D L I Q U I D C A PA C I T Y TA B L E - ‘A’ C O R E SDA-032/S SDA-033/S SDA-052/S SDA-053/S SDA-082/S SDA-083/S SDA-084/S SDA-162/S SDA-163/S SDA-164/S SDA-165/S SDA-303/S SDA-304/S SDA-305/S SDA-306/S SDA-413/S SDA-414/S SDA-415/S SDA-416/S Conn Size (inch) 1/4 3/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 5/8 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 Drying Capacity (kg of refrigerant) R22 24°C 4.3 4.3 8.6 8.6 13.8 13.8 13.8 21.5 21.5 21.5 21.5 44.8 44.8 44.8 44.8 67.1 67.1 67.1 67.1 52°C 4 4 8 8 12.8 12.8 12.8 19.9 19.9 19.9 19.9 41.5 41.5 41.5 41.5 62.2 62.2 62.2 62.2 R134a/R507 24°C 52°C 4.6 4.4 4.6 4.4 9.2 8.8 9.2 8.8 14.8 14.1 14.8 14.1 14.8 14.1 23.1 22 23.1 22 23.1 22 23.1 22 48.1 45.7 48.1 45.7 48.1 45.7 48.1 45.7 72.1 68.6 72.1 68.6 72.1 68.6 72.1 68.6 R404A 24°C 7.4 7.4 14.8 14.8 23.7 23.7 23.7 37 37 37 37 77 77 77 77 115.5 115.5 115.5 115.5 52°C 4 4 8 8 12.8 12.8 12.8 19.9 19.9 19.9 19.9 41.5 41.5 41.5 41.5 62.2 62.2 62.2 62.2 Liquid Capacity (kW) R407C/R410A 24°C 52°C 4.5 3.9 4.5 3.9 9.1 7.7 9.1 7.7 14.5 12.4 14.5 12.4 14.5 12.4 22.6 19.3 22.6 19.3 22.6 19.3 22.6 19.3 47.1 40.2 47.1 40.2 47.1 40.2 47.1 40.2 70.6 60.2 70.6 60.2 70.6 60.2 70.6 60.2 Drying Capacity is based on the following moisture content before and after drying: R22: R134a: R404A, R407C, R507: R410A: From 1050 ppm W to 60 ppw W in accordance with ARI 710-86 From 1050 ppm W to 75 ppm W. If refrigerant is to be dried to 50 ppm W, reduce the stated capacites by 15% From 1020 ppm W to 30 ppm W From 1050 ppm W to 60 ppm W Liquid Capacity is based on: Evaporating temperature of te = -15°C (-30°C for CO2 ) Condensing temperature of tc = +30°C (-5°C for CO2 ) Pressure drop across filter-drier of Δp = 0.07 bar AC &R C OMPO NENTS PRO DUCTS Model Details Part No 4 SEALED FILTER DRIERS S U R FA C E A N D V O L U M E I N F O R M AT I O N Model SDM/SDA-03 SDM/SDA-05 SDM/SDA-08 SDM/SDA-16 SDM/SDA-30 SDM/SDA-41 Core surface area cm2 64 127 180 290 442 551 A C I D C A PA C I T Y I N F O R M AT I O N Model SDA-03 SDA-05 SDA-08 SDA-16 SDA-30 SDA-41 AC &R C OMPO NENTS PRO DUCTS *Absorption capacity of oleic acid at 0.05TAN (Total Acid Number) 5 Acid Capacity* g 0.8 1.6 2.6 4 8.3 12.5 Core Volume cm3 43 90 146 219 451 649 Shell Volume ltr 0.1 0.2 0.3 0.5 0.9 1.3 SEALED FILTER DRIERS The information contained in this brochure is correct at the time of publication. Henry Technologies has a policy of continuous product development; we therefore reserve the right to change technical specifications without prior notice. Extensive changes within our industry have seen products of Henry Technologies being used in a variety of new applications. We have a policy, where possible, to offer research and development assistance to our clients. We readily submit our products for assessment at the development stage, to enable our clients to ascertain product suitability for a given design application. It remains the responsibility of the system designer to ensure all products used in the system are suitable for the application. For details of our warranty cover, please refer to our standard terms and conditions of sale. Copies are available on request. Henry Technologies 76 Mossland Road Hillington Park Glasgow G52 4XZ Scotland UK Tel. +44 141 882 4621 Fax. +44 141 810 9199 enquiries@henrytech.co.uk www.henrytech.co.uk FOLLOW US ON: Date of publication:- June 2012 AC &R C OMPO NENTS PRO DUCTS NOTES: 6