WESCHLER INSTRUMENTS AEMC Ground Resistance Testers Digital Ground Resistance Tester Models 4620 & 4630 • Measures soil resistivity (4-Point) method • Measures ground resistance (2- and 3-Point) Fall-of-Potential method • Step voltage tests and touch potential measurements • Auto-Ranging: automatically selects the optimum range • Designed to reject high levels of noise and interference • Extremely simple to operate: connect – press – read • LED on faceplate informs operator of high input noise, high auxiliary rod resistance and fault connections • Large easy-to-read backlit display • Battery powered (Model 4620) • AC powered with rechargeable NiMH batteries (Model 4630) • Rugged dustproof and rainproof field case • Can also be used for continuity tests on bonding • Color-coded terminals Clamp-On Ground Resistance Tester Models 3711 & 3731 ▲ 3731 US Patent No. 362,639 ▲ 4630 • Simple and fast clamp-on operation — no leads, no auxiliary rods or spacing requirements • Direct reading of ground resistance from 0.1Ω to 1200Ω • Direct reading of continuity and ground loop resistance • Direct reading of ground leakage or phase current from 1mA to 30Arms • Jaw design with large 1.25" (32mm) window — accommodates up to 1000MCM cables • Auto-Off for power management • Alarm function with adjustable set point and buzzer for quick field checks (Model 3731) • Memory function to store 99 field measurements for later retrieval and analysis (Model 3731) • Meets EN 61010-1, Cat. III and CE Mark • Rugged Lexan® head and body construction resists breakage • Alarm settings and stored memory information saved during shutdown (Model 3731) • Patented design Also available as full kits Digital Ground Resistance Tester Model 4500 Ground Resistance Tester Models 3620, 3640 & 4610 ▲ ▲ 4610 Kit 4610 Available as standalone unit or in kit form • Measures soil resistivity (4-Point) method (Model 4610) • Large analog display for Model 3620 • Designed to reject high levels of noise and interference • Auto-Ranging: automatically selects the optimum range for Models 3640 and 4610 • Battery powered • Performs Fall-of-Potential method • All units measure ground resistance (2- & 3-Point) • Extremely simple to operate: connect – press – read • Indicator error lights • Rugged dustproof and rainproof case • Color-coded terminals and lead identification • Large LCD digital display (Models 3640 & 4610) • Supplied with a protective carrying case • Measure ground resistance (2- & 3-Point) Fall-of-Potential method and soil resistivity (4-Point) • Step voltage tests and touch potential measurements • Selectable: three test currents and five resistance ranges • Measure very low resistance on large grounding systems and grids • High test current also enables geological surveys • Large LCD display for easy reading • Display includes indicators for excess stray current and voltage, high auxiliary rod resistance and faulty connection • Battery (rechargeable 110V/220V) powered or external 12VDC • Rugged dustproof and rainproof case • Can be used for continuity tests on bonding ▲ 4500 ORDERING INFORMATION AE/2130.43 Ground Resistance Tester Model 4620 (4-Point, Digital, Battery Powered) AE/2114.94 AE/2114.91 Ground Resistance Tester Model 3620 Kit AE/2130.44 Ground Resistance Tester Model 4630 (4-Point, Digital, Rechargeable Battery) AE/2114.93 Ground Resistance Tester Model 3640 Kit AE/2114.95 Ground Resistance Tester Model 4610 Kit AE/2130.45 Ground Resistance Tester Model 4620 Kit AE/2117.60 Ground Resistance Tester Model 3711 (Clamp-On) AE/2130.46 Ground Resistance Tester Model 4630 Kit AE/2117.61 AE/2114.90 Ground Resistance Tester Model 3620 (3-Point, Analog) Ground Resistance Tester Model 3731 (Clamp-On with memory and alarm) AE/2114.92 Ground Resistance Tester Model 3640 (3-Point, Digital) AE/450.100 Digital Ground Resistance Tester Model 4500 (4-Point, Digital) 155 Ground Resistance Tester Model 4610 (4-Point, Digital) WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com WESCHLER INSTRUMENTS Megger® Ground Resistance Testers Three-Terminal Ground Resistance Testers ® BIDDLE Model 250260 is the tried and proven analog version. It is a simple, three-terminal tester that will tolerate 2 V peakto-peak voltage interference. The MEGGER® DET62D is also an economical, three-terminal model but with autoranging digital display, and an industry best 40 V peak-to-peak tolerance. Six 1.5 V “AA” dry cells provide power for the DET62D, allowing 700 typical 15-second tests. Addition of a fourth terminal permits resistivity (soil conductivity) testing in addition to resistance (installed ground) measurements. The DET3/2 has a 4-position range selector switch and is powered by an always-ready hand-crank generator. It offers 20V peakto-peak interference tolerance. The DET5/4R and DET5/4D are autoranging for either 3- or 4terminal testing and tolerate 40V peak-to-peak interference. DET 3/2 ▲ ▲ 250260 Four-Terminal Ground Resistance Testers ▲ ▲ For testing in extreme electrical environments, the DET2/2 offers 0.001Ω resolution, adjustable test frequency and additional interference filtering. DET 62 DET 5/4R ORDERING INFORMATION Catalog No. ME/250260 ME/DET62D Model No. ME/DET5/4D DET5/4D ME/DET5/4R DET5/4R ME/250302 DET3/2 ME/250202 DET2/2 DET62D Range Resistance 0.5 - 500Ω 0.1 - 199.9Ω 0.001 kΩ - 1.999 kΩ 0.01 - 19.99Ω 0.1 - 199.9Ω 0.001 - 1.999 kΩ 0.01 - 19.99 kΩ 0.01 - 19.99Ω 0.1 - 199.9Ω 1.0Ω - 1.999 kΩ 10Ω - 19.99 kΩ 0.010Ω - 19.99kΩ Power Source Battery Battery Display Analog Digital Testing Application Simple Ground System Battery Digital Larger, more complex grounding systems; moderate ac interference voltages present Digital Complex systems; extreme ac interference Rechargeable Lead-Acid Battery Hand-cranked Rechargeable Battery ACCESSORY KITS Catalog No. ME/250581 ME/250583 ME/250560 Contents Set of three color-coded test leads, 25, 50, 100 ft. (8, 15, 30 m); Pair of 20-in. (51 cm) grounding rods; padded case to hold instrument, leads and rods Set of three test leads, 12, 31, 50 ft. (3.6, 9.4, 15 m); Pair of 11-in. (28 cm) ground rods; calibration standard Used With 250202, DET5/4D, DET5/4R, DET62D 250302 250260 156 WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com WESCHLER INSTRUMENTS ▲ Ground Resistance Testers • Easy, fast clamp-on operation – No rods or cables necessary • Measures ground resistance from 0.025Ω to 1500Ω • Measures ground leakage or phase current from 0.2mA to 35A • Auto ranging with high and low alarms • Automatic self calibration DET20C APPLICATIONS • Measure resistance and continuity of grounding loops around pads and buildings. • Check multi-grounded systems without disconnecting the ground rod/stake under test. • Measure leakage current flowing to ground or circulating in ground systems. • Use on cell towers, RF transmitters and telecommunications sites. • Inspect and verify lightning protection systems. • Test consumer installations, including pools, spas, etc. FEATURES • Large LCD display screen can be read in bright sunlight. • Large 1.36" (35mm) jaw opening to accommodate a variety of conductors. • Indication of high noise content that may affect readings. • Hold function for difficult to reach installations. • Auto-off to save on battery power. • Configurable high and low alarms with audible indication for fast field checks. • On board storage of test results (up to 8180 records). • Calibration check loop to insure proper operation. • Rugged construction for regular field use. • Lightweight storage case contains complete testing kit. Model DET20C includes RS-232 interface and software for downloading test data. Both models include battery, carrying case & calibration loop. ORDERING INFORMATION ME/DET10C ME/DET20C 157 Digital Earth Test Clampmeter Digital Earth Test Clampmeter with RS-232 Interface Hioki Battery Testers ▲ Megger® Clamp-on Testers NEW 3551 • Test Without Disconnecting the Battery • Three Level Indication: Pass, Warning, Fail • Temperature Correction Get an instantaneous check of battery condition based on internal resistance and voltage. Model 3550 for medium-capacity alkali and lead-acid storage batteries: UPS and similar applications. Model 3551 for high-capacity alkali and lead-acid storage batteries. Model 3555 for compact storage batteries: portable telephones and similar applications. SPECIFICATIONS Measurement Ranges: Ohms: 3550: 30mΩ to 3Ω, 3 ranges, 10µΩ resolution max. 3551: 3mΩ to 300mΩ, 3 ranges, 1µΩ resolution max. 3555: 300 mΩ to 30Ω, 3 ranges, 100µΩ resolution max. Volts: 3 or 30V DC, 2 ranges, 1mV resolution max. Temperature: -10 to 60°C, 1 range, 0.1°C resolution (platinum sensor)* Comparator: Upper and lower limit for resistance; lower limit for voltage Alert: LED & beep output Operating Temperature: 0-40ºC, <80% RH (non-condensing) Test Frequency: 1kHz Max. Input: 50VDC Power: 6 AA batteries Dimensions: 7.8"W x 5.2"H x 2"D Supplied Accessories: 3550: Clip-type lead with temperature sensor, carrying case 3551: Pin-type lead, remote control switch, carrying case 3555: Pin-type lead *Temperature measurement with the 3551 requires the optional 9460 lead. Temperature not available on the 3555. ORDERING INFORMATION HK/3550 HK/3551 HK/3555 HK/9460 HK/9382 HK/9418-10 Battery HiTester (medium capacity alkaline & lead acid) Battery HiTester (high capacity alkaline & lead acid) Battery HiTester (compact storage batteries) Clip-type lead with temperature sensor Carrying case for 3555 AC adapter for 3551 WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com