Bussmann® LOW-PEAK LPJ ® Dual-Element Time-Delay Fuses Class J – 600 Volt Dimensional Data 2.25" (± 0.03) .81" .5" (± 0.03) 1A to 30A 2.38" (± 0.03) .63" 35A to 60A 1.06" (± 0.03) Catalog Symbol: LPJ-_SP Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Ampere Rating: 1 to 60A Voltage Rating: 600Vac (or less) 300Vdc (or less) Interrupting Rating: 300,000A RMS Sym. (UL) 100,000A dc Agency Information: UL Listed — Special Purpose*, Guide JFHR, File E56412 CSA Certified, 200,000 AIR, Class J per CSA 22.2 No. 248.8 Class 1422-02, File 53787 1-60 Amps General Information: • True dual-element fuses with a minimum 10 second timedelay at 500% overload. • Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges. • Can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail. • High interrupting rating to safely interrupt overcurrents up to 300,000A. • High degree of current limitation due to the fast speed-ofresponse to short-circuits. • Faster response to damaging short-circuit currents than mechanical overcurrent protective devices. • Reduces let-through thermal and magnetic forces in order to protect low withstand rated components. • Proper sizing provides “no damage” Type “2” coordinated protection for NEMA and IEC motor control in accordance with IEC Standard 947-4-1. • Dual-element fuses have lower resistance than ordinary fuses so they run cooler. • Lower watts loss reduces power consumption. • Unique dimensions assure that another class of fuse with a lesser voltage rating, interrupting rating or current-Iimiting ability cannot be substituted. • Space-saving package for equipment down sizing. *Meets all performance requirements of UL Standard 248-8 for Class J fuses. Catalog Symbol and Ampere Ratings LPJ-1SP LPJ-3SP LPJ-7SP LPJ-25SP LPJ-1⁄Ω¢SP LPJ-3-¤Ω¡ºSP LPJ-8SP LPJ-30SP LPJ-1-flΩ¡ºSP LPJ-3⁄Ω™SP LPJ-9SP LPJ-35SP LPJ-1-°Ω¡ºSP LPJ-4SP LPJ-10SP LPJ-40SP LPJ-2SP LPJ-4⁄Ω™SP LPJ-12SP LPJ-45SP LPJ-2⁄Ω¢SP LPJ-5SP LPJ-15SP LPJ-50SP LPJ-2⁄Ω™SP LPJ-5flΩ¡ºSP LPJ-17⁄Ω™SP LPJ-60SP LPJ-2°Ω¡ºSP LPJ-6SP LPJ-20SP Recommended fuseblocks/fuseholders for Class J 600V fuses See Data Sheets listed below • Finger-safe fuseholders - 1152 • Open fuseblocks - 1114 • Open pyramid fuseblocks - 1108 Carton Quantity and Weight Ampere Ratings Weight** Carton Qty. Lbs. Kg. 1–30 10 1.09 0.494 35–60 10 1.78 0.808 **Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 10-2-02 SB02295 Form No. LPJ 1-60 Page 1 of 3 Data Sheet: 1006 Bussmann® LOW-PEAK® LPJ Dual-Element Time-Delay Fuses Class J – 600 Volt 1-60 Amps 60A 30A 15A 10A 6A 3A 1A Time-Current Characteristic Curves–Average Melt AMPERE RATING 300 200 100 TIME IN SECONDS 10 1 1,000 100 1 .01 10 .1 CURRENT IN AMPERES 10-2-02 SB02295 Form No. LPJ 1-60 Page 2 of 3 Data Sheet: 1006 Bussmann® LOW-PEAK® Dual-Element Time-Delay Fuses Class J – 600 Volt LPJ 1-60 Amps Current Limitation Curves The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 10-2-02 SB02295 Form No. LPJ 1-60 Page 3 of 3 Data Sheet: 1006 Bussmann® LOW-PEAK® LPJ Dual-Element, Time-Delay Fuses Class J – 600 Volt 70 to 600A Dimensional Data 4.63" (– 0.03) 3.63" 2.63" .75" 1.13" (– 0.03) 1" .28" .43" 70A to 100A .13" 5.75" (– 0.03) 4.38" 3.0" 110A to 200A .43" 1.13" .28" 1.63" (– 0.03) 1.38" .19" 225A to 400A Catalog Symbol: LPJ-_SP Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Ampere Rating: 70 to 600A Voltage Rating: 600Vac (or less)* Interrupting Rating: 300,000A RMS Sym. Agency Information: UL Listed – Special Purpose†, Guide JFHR, File E56412 CSA Certified, Class J per CSA C22.2 No. 248.8, Class 1422-02, File 53787 *0-600A rated 300Vdc and 20 KAIC. †Meets all performance requirements of UL Standard 248-8 for Class J fuses. Catalog Symbol and Ampere Ratings LPJ-70SP LPJ-125SP LPJ-250SP LPJ-500SP LPJ-80SP LPJ-150SP LPJ-300SP LPJ-600SP LPJ-90SP LPJ-175SP LPJ-350SP — LPJ-100SP LPJ-200SP LPJ-400SP — LPJ-110SP LPJ-225SP LPJ-450SP — Carton Quantity and Weight Weight* Ampere Ratings Carton Qty. Lbs. Kg. 70–100 5 1.69 0.767 110–200 5 4.21 1.910 225–400 1 1.67 0.758 450–600 1 2.80 1.270 *Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 10-8-03 A03094 450A to 600A General Information: • True dual-element fuses with a minimum 10 second timedelay at 500% overload. • Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges. • Can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail. • High interrupting rating to safely interrupt overcurrents up to 300,000A. • High degree of current-limitation due to the fast speed-ofresponse to short-circuits. • Faster response to damaging short-circuit currents than mechanical overcurrent protective devices. • Reduces let-through thermal and magnetic forces in order to protect low withstand rated components. • Proper sizing provides “no damage” Type “2” coordinated protection for NEMA and IEC motor control in accordance with IEC Standard 947-4-1. • Dual-element fuses have lower resistance than ordinary fuses, hence they run cooler. • Lower watts loss reduces power consumption. • Unique dimensions assure that another class of fuse with a lesser voltage rating, interrupting rating or current-Iimiting ability cannot be substituted. • Space-saving package for equipment down sizing. Form No. LPJ 70-600 Page 1 of 3 Data Sheet: 1007 Bussmann® LOW-PEAK® LPJ Dual-Element, Time-Delay Fuses Class J – 600 Volt 70-600A Recommended fuseblocks for Class J 600V fuses See Data Sheet: 1114 600A 400A 200A 250A 125A 80A 100A Time-Current Characteristic Curves–Average Melt AMPERE RATING 300 200 100 TIME IN SECONDS 10 1 .1 10,000 100 1,000 .01 CURRENT IN AMPERES 10-8-03 A03094 Form No. LPJ 70-600 Page 2 of 3 Data Sheet: 1007 Bussmann® LOW-PEAK® Dual-Element, Time-Delay Fuses Class J – 600 Volt LPJ 70-600A Current-Limitation Curves The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 10-8-03 A03094 Form No. LPJ 70-600 Page 3 of 3 Data Sheet: 1007 Bussmann® LOW-PEAK® LP-CC Time-Delay Fuses Class CC – 600 Volt, ⁄Ω™ to 30 Amps Dimensional Data 1.5" (±0.031) (38.1mm) .41" (±0.005) (10.3mm) Catalog Symbol: LP-CC Time-Delay, Current-Limiting Ampere Rating: ⁄Ω™ to 30A AC Voltage Rating: 600V (or less) Interrupting Rating: 200,000A RMS Sym. Agency Information: UL Listed, Std. 248-4, Class CC, Guide JDDZ, File E4273 CSA Certified, C22.2 No. 248.4, Class 1422-02, File 53787 DC Voltage Rating: 300Vdc (or less) ⁄Ω™-2 °/⁄‚A and 20-30A, 20,000 AIR, UL 198L 150Vdc or less 3-15A, 20,000 AIR, UL 198L Catalog Numbers LP-CC-⁄Ω™ LP-CC-1⁄Ω™ LP-CC-3 LP-CC-6 LP-CC-12 LP-CC-flΩ¡º LP-CC-1flΩ¡º LP-CC-3¤Ω¡º LP-CC-6⁄Ω¢ LP-CC-15 LP-CC-°Ω¡º LP-CC-1°Ω¡º LP-CC-3⁄Ω™ LP-CC-7 LP-CC-20 LP-CC-1 LP-CC-2 LP-CC-4 LP-CC-7⁄Ω™ LP-CC-25 LP-CC-1⁄Ω• LP-CC-2⁄Ω¢ LP-CC-4⁄Ω™ LP-CC-8 LP-CC-30 LP-CC-1⁄Ω¢ LP-CC-2⁄Ω™ LP-CC-5 LP-CC-9 — LP-CC-1›Ω¡º LP-CC-2°Ω¡º LP-CC-5flΩ¡º LP-CC-10 — Carton Quantity and Weight Ampere Ratings Weight* Carton Qty. Lbs. Kg. 10 .193 .088 0-30 *Weight per carton. Recommended fuseblocks/fuseholders for Class CC 600V fuses See Data Sheets listed below • Open fuseblocks - 1105 • Finger-safe fuseholders - 1109, 1102, 1103, 1151 • Panel-mount fuseholders - 2114, 2113 • In-line fuseholders - 2126 General Information: LP-CC LOW-PEAK Yellow™ Fuse • A superior all-purpose, space-saving branch circuit fuse that meets most protection requirements up to 30A. • Very compact; physical size is only ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) with rejection tip. • The unique yellow color makes it easy to tell that the correct fuse type is installed. • Faster response to damaging short-circuit currents and higher interrupting rating than mechanical overcurrent protective devices. 200,000A Interrupting Rating • Maximum interrupting rating for available fault current in today's large capacity systems. • Helps ensure that future growth will not obsolete the system. Dual Characteristics • Time-delay to avoid unwanted fuse openings from surge currents. • Fast speed of response under short-circuit conditions for a high degree of current-limitation. • ADVANTAGE: The LOW-PEAK ® fuse can be sized close to full load ratings for maximum overload and short-circuit protection. • ADVANTAGE: Can be used where either a time-delay or a fast-acting fuse is needed, making selection easier and reducing spare fuse inventories for substantial cost reduction. Superior Motor Protection • For protection of small horsepower motor circuits. • Proper sizing can provide Type “2” coordinated protection for NEMA and IEC motor controllers. • Motors receive maximum protection against burnout from overloads and single phasing. Current-Limiting Effects Prospective Short- *Let-Through Current (Apparent RMS Symmetrical) Circuit Current 1⁄Ω¢A 2°Ω¡ºA 15A 20A 25A 30A 1,000 100 135 240 305 380 435 3,000 140 210 350 440 575 580 5,000 165 255 420 570 690 710 10,000 210 340 540 700 870 1,000 20,000 260 435 680 870 1,090 1,305 30,000 290 525 800 1,030 1,300 1,520 40,000 315 610 870 1,150 1,390 1,700 50,000 340 650 915 1,215 1,520 1,820 60,000 350 735 1,050 1,300 1,650 1,980 80,000 390 785 1,130 1,500 1,780 2,180 100,000 420 830 1,210 1,600 2,000 2,400 200,000 525 1,100 1,600 2,000 2,520 3,050 *RMS Symmetrical Amperes Short-Circuit NOTE: To calculate Ip (Ipeak) multiply IRMS value ≈ 2.3. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. 10-2-02 SB02295 Form No. LP-CC Page 1 of 2 Data Sheet: 1023 Bussmann® LOW-PEAK® LP-CC AMPERE RATING 2-8/10 300 1-1/4 200 100 80 60 50 40 30 2,000 800 1,000 400 500 600 300 200 80 100 20 1,000 CURRENT IN AMPERES 100 10 1 PROSPECTIVE SHORT-CIRCUIT CURRENT–SYMMETRICAL RMS AMPS .4 .01 AMPERE RATING 600 500 400 10 .1 30 25 20 15 1,000 800 40 50 60 1 2,000 30 10 3,000 20 100 TIME IN SECONDS 4,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 200 10 3 3⁄Ω™ 4 4⁄Ω™ 6 8 10 12 15 20 25 30 ⁄Ω™ flΩ¡º °Ω¡º 1 1⁄Ω¢ Time-Delay Fuses Class CC – 600 Volt, ⁄Ω™ to 30 Amps The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 10-2-02 SB02295 Form No. LP-CC Page 2 of 2 Data Sheet: 1023 Bussmann® Class J Fuseblocks J600 Series 600 Volt, ⁄Ω™-600 Amps Catalog Symbol: J600 Series Ampere Rating: ⁄Ω™-600A Voltage Rating: 600V Withstand Rating: 200,000 RMS Sym. Amps For use with Class J Fuses (Bussmann LPJ, JKS) Agency Information: UL Listed, UL 512, Guide IZLT, File E14853 CSA Certified, C22.2 No. 39, Class 6225-01, File 47235 UL Flammability: 94VO Materials: Thermoplastic Standard J Fuseblocks (600V) Catalog Data Amps ⁄Ω™-30 31-60 61-100 101-200 201-400 401-600 Poles Screw† Pressure Plate† 1 2 3 1 2 3 1 3 1 3 1 3 1 3 J60030-1S(2) J60030-2S(2) J60030-3S(2) — — — — — — — — — — — J60030-1P J60030-2P J60030-3P — — — — — — — — — — — Catalog Numbers Box Box Lug w/ Lug Retaining Clip J60030-1C J60030-2C J60030-3C J60060-1C J60060-2C J60060-3C — — — — — — — — Fig. No. J60030-1CR†† 1 J60030-2CR†† 2 J60030-3CR†† 3 J60060-1CR†† 1 J60060-2CR†† 2 J60060-3CR†† 3 J60100-1CR 4 J60100-3CR†† 5 J60200-1CR 6 J60200-3CR 7 J60400-1CR(3) 8 J60400-3CR(3) 9 J60600-1CR 10 J60600-3CR(2) 11 Wire Range C, CR #2-14 CU, #2-8 AL COR #2-14 CU ONLY P, PR, S, SR #10-14 CU ONLY C, CR, #2-14 CU/AL COR #4-14 CU ONLY COR 1/0-8 CU ONLY CR, CRQ 1/0-8 CU/AL CR 250kcmil-6 CU/AL CR 500kcmil -4 CU/AL CR (2) 500kcmil-4/0 CU/AL †Clip reinforcing springs are standard on fuseblocks rated 100A and above. Available on 30A and 60A blocks by adding the letter “R” to the end of the part number. ††Copper only connections available by changing “CR” suffix to “COR”. (2)No UL, No CSA Certification (3)UL Recognized, CSA Certification Dimensional Data All dimensions (±0.015) 61-100A ⁄Ω™-60A 1.702" 3.202" .750" 2.250" 4.702" 2.415" 2.250" 750" 5" 2.28" .30" C L 4.005" .94" 1.583" .22" Dia. .5" C'Bore 6.28" CL 3.14" 1.500" 1.75" FIGURE 1. FIGURE 2. FIGURE 3. FIGURE 4. 1.5" FIGURE 5. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 11-12-03 SB03116 Form No. J600 Series Page 1 of 2 Data Sheet: 1114 Bussmann® Class J Fuseblocks J600 Series 600 Volt, ⁄Ω™-600 Amps 101-200A 3.1" 3.06" .75" c'bore 6.125" 7.00" .31" .5" 3.15" 8.31" .75" 3" 2" .344" dia. hole through .750 dia. c'bore 6.125" 1.69" .34" dia. .750" FIGURE 7. FIGURE 6. 201-400A 10.51" 4" 3" 1.75" .56" .625" 3.5" 7.50" .75" c'bore .34" dia. 7.5" 4.00" 9.00" 6.00" 1" .344" dia. hole through .750 dia. c'bore 2.00" .50" .5" 1.00" FIGURE 8. FIGURE 9. 401-600A 4.99" 4" 1.75" 1.125" 4.99" 14.144" 1" 11.00" .56" 3.25" 8.875" .75" c'bore .34" dia. 2.375" FIGURE 10. .344" dia. hole through .750 dia. c'bore 8.875" 2.88" FIGURE 11. .50" 1.00" All dimensions (±0.015) The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 11-12-03 SB03116 Form No. J600 Series Page 2 of 2 Data Sheet: 1114 Cooper Bussmann CH Series Modular Fuse Holders Class J Class J – 600 Volt 1-60A Features: • Choice of Indication: –Easy ID window to view indicator on Cooper Bussmann LPJ-(amp)SPI fuses for permanent fuse indication, even when power is disconnected. –Neon indicator is field installable or can be purchased installed from the factory. • Comes in standard 1, 2 & 3 Pole ganged assemblies where all fuses are extracted simultaneously. • Kits are available for ganging units in the field. • Meets requirements of IEC 60529 for IP-20 finger safe rating. • 35mm DIN rail and chassis (6-32 UNC Pan Head Recommended) mounting features. • Fuseholder wire ports dual wire rated from 18 to 3AWG. Specifications: Fuse Sizes Voltage Rating Amperage Rating 35 to 60A Class J 600V 600V 30A 60A Torque IP Rating 18-1AWG Single 18-3AWG Dual 75°C 35in-lbs IP-20 (Finger Safe) 18-1AWG Single 18-3AWG Dual 75°C 35in-lbs IP-20 (Finger Safe) Clip Material Tin Plated Copper Tin Plated Copper UL 94 VO Thermoplastic 90V UL 94 VO Thermoplastic 90V 34mA (460Vac) 34mA (460Vac) Wire Range Housing Material Catalog Symbol: CH30J_(I) CH60J_ (I) Ampere Rating: 1 to 60A Voltage Rating: 600Vac (or less) Interrupting Rating: 200,000A RMS Sym. Agency Approvals: Listed UL 512, Guide IZLT, File E14853 CSA Certified per C22.2 Nos. 39 Class 6225-01, File LR47235 Other Electrical Certifications: CE compliance for the European Union Low Voltage Directive Recommended Cooper Bussmann Fuses: Class J Time Delay LPJ (Data Sheet 1006) Class J Fast Acting JKS (Data Sheet 1026) 0 to 30A Class J Minimum Indicating Voltage (Neon Lamp) Nominal Operating Current (Neon Lamp) Max Operating Temperature Storage Temperature 85°C 85°C -20°C to +65°C -20°C to +65°C CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Cooper Bussmann Application Engineering at 314-527-1270 for more information. 7-5-05 SB05189 Form No. Class J 1-60 Page 1 of 2 Data Sheet: 2144 Cooper Bussmann CH Series Modular Fuse Holders Class J Class J – 600 Volt 1-60A E H D G Dimensional Data F 3 POLE CLASS J Modular Fuse Holder Dimension CH30J in [mm] CH60J in [mm] A 1.28 [32.5] 1.58 [40.0] B 2.56 [65.0] 3.16 [80.0] C 3.84 [97.5] 4.72 [120.0] D 4.59 [116.6] 4.88 [124.0] E 2.83 [71.8] 3.31 [84.1] F 3.56 [90.4] 3.85 [97.9] G 1.28 [32.5] 1.58 [40.0] H 0.18 [4.44] 0.18 [4.44] A B C Catalog Numbers Easy ID Window 30A Class J 30A AND 60A Ganging Assembly 60A Class J Neon Indicating 1Pole CH30J1 CH30J1I 2Pole CH30J2 CH30J2I 3Pole CH30J3 CH30J3I 1Pole CH60J1 CH60J1I 2Pole CH60J2 CH60J2I 3Pole CH60J3 CH60J3I Accessories Part Number Description Carton Qty. 2A1073 Ganging Kit (3 Pole) 2 Spring Pins 6 Plastic Connectors 2A1164 Neon Indication 3 2A1777 Circuit Markers 100 INDICATOR ASSEMBLING The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 7-5-05 SB05189 Form No. Class J 1-60 Page 2 of 2 Data Sheet: 2144 Bussmann® Class CC Fuseblocks BCA Series 600 Volt, 30 Amps Dimensional Data All dimensions ±.015’’ (.38mm) Catalog Symbol: BCA Series Class CC Fuseblocks For use with Class CC Fuses (Bussmann LP-CC, KTK-R, and FRQ-R) Ampere Rating: ⁄Ω¡º to 30 Voltage Rating: 600V Withstand Rating: 200,000A, RMS Sym. Agency Information: UL Listed, UL 512, Guide IZLT, File E14853 CSA Certified, C22.2 No. 39, Class 6225-01, File 47235 UL Flammability: 94 VO Materials: Base - Thermoplastic Clips - Bright tin-plated bronze Catalog Data Terminal Type Amps ⁄Ω¡º to 30 Poles Adder 1 2 3 Screw with Quick Connect* BCA603ASQ BCA6031SQ BCA6032SQ BCA6033SQ Pressure Plate with Quick Connect* BCA603APQ BCA6031PQ BCA6032PQ BCA6033PQ Fuse blocks feature a unique adder block which can be snapped onto 1-, 2-, or 3-pole blocks to form multi-pole segmented blocks of as many poles as desired. Wire Range CU Only #10-#18 *QUICK CONNECT RATED FOR 20A MAXIMUM. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 4-12-05 SB05085 Form No. BCA Series Page 1 of 1 Data Sheet: 1154