Specification Sheet EMC CLARiiON DC Power CX3 Model 20 Networked Storage System Specifications RAID Levels RAID 0: Data striped across three to 16 drives RAID 1: Mirrored pairs of two drives RAID 1/0: Data mirrored, then striped across four to 16 drives RAID 3: Independent data access on five or nine drives (with dedicated parity disk) RAID 5: Independent data access on three to 16 drives (with striped parity) RAID 6: Dual parity distributed across four to 16 drives Any combination of these RAID levels can exist on a single DC Power CX3 model 20 RAID stripe depth configurable to 4, 16, 64, 128, or 256 sectors per disk MetaLUNs: Storage virtualization via online LUN expansion through either striping or concatenation Configurable global hot spares Rebuild priority tuning: adjustment of minimum I/O reserved for server use during rebuild Front-End (Host) Connectivity EMC® CLARiiON® DC Power CX3 systems can be integral elements of a comprehensive information lifecycle management strategy—a strategy that helps your enterprise attain the maximum value from its information, at the lowest TCO, at every point in the information lifecycle. Information lifecycle management maps the right service level to the right application at the right cost—at the right time. Two storage processors per DC Power CX3 model 20 CX3-20 DC Power Six 4 Gb Fibre Channel optical ports Each storage processor has FCP SCSI-3 protocol FC-AL and FC-SW support Maximum Cable Length Shortwave Optical: 100 meters (4 Gb), 300 meters (2 Gb), 500 meters (1 Gb) Command tag queuing up to 256 tags Back-End (Disk) Connectivity Each storage processor has one 4 Gb Fibre Channel Arbitrated Loop. Multiple RAID groups may be distributed across redundant loops to maximize bandwidth to disks. DC Power CX3 model 20 supports a maximum of 120 disk drives. Drive Interface Failover from each storage processor to both Fibre Channel loops is possible. Nominal Capacity 73 GB 146 GB 300 GB (10,000) (10,000) (10,000) 73 GB 4 Gb/s (15,000) 146 GB 4 Gb/s (15,000) 135 GB 272 GB 67.7 GB 135 GB 67.7 GB Formatted Capacity* (520 bytes/sector, 1 MB = 1,048,576 bytes) Form Factor 3.5” 3.5” 3.5” 3.5” 3.5” Height 1.0” 1.0” 1.0” 1.0” 1.0” Rotational Speed 10,000 rpm 10,000 rpm 10,000 rpm 15,000 rpm 15,000 rpm Interface Fibre Channel Fibre Channel Fibre Channel Fibre Channel Fibre Channel Data Buffer 16 MB 32 MB 32 MB 32 MB 32 MB Transfer Rates Buffer to/from Media 59–118 MB/s 59–118 MB/s 59–118 MB/s max. 93 MB/s max. 93 MB/s 200 MB/s 200 MB/s 400 MB/s 400 MB/s SP to/from Buffer (max.) 200 MB/s Access Time 4.7 ms Read 4.7 ms Read 4.7 ms Read 3.6 ms Read 3.7 ms Read Average Seek 5.4 ms Write 4.1 ms Write 4.2 ms Write 5.4 ms Write 5.4 ms Write Rotational Latency 3 ms 3 ms 3 ms 2 ms 2 ms * Note: The FLARE® storage operating environment requires 33 GB of disk space on each of the first five drives. 300 GB 4 Gb/s (15,000) 272 GB 3.5” 1.0” 15,000 rpm Fibre Channel 16 MB 120–201 MB/s 400 MB/s 3.5 ms Read 4.0 ms Write 2 ms Available Software* SnapView™: point-in-time view of information for nondisruptive backup and clones MirrorView™: remote synchronous replication for disaster protection RecoverPoint/SE: remote asynchronous replication for disaster protection Online Upgrade: online upgrades of storage software and FLARE operating system Navisphere® Manager: complete configuration, management, and event notification Navisphere Analyzer: comprehensive performance, management, and trends analysis Navisphere Quality of Service Manager: application service-level monitoring and management CLARalert™: constant system monitoring, call-home notification, and remote diagnostics PowerPath®: path failover for continuous data access and dynamic load balancing SAN Copy™: enables local or long distance data movement between various arrays (e.g., CLARiiON, Symmetrix®, HP StorageWorks) VisualSAN®/VisualSRM™: data protection, shared storage access, SAN management Replication Manager Family: manages the replication process (host and replication software) to integrate SnapView and MirrorView operations VMware®: enables server consolidation with CLARiiON storage * Consult your EMC account manager for availability, software configuration, and compatibility information. System Memory Two Storage Processors per DC Power CX3 model 20 2 GB of Memory per Storage Processor Dimensions (approximate) Rackmount Processor Chassis Height 3.5 in. (8.9 cm), 2 EIA units Width 18.92 in. (48.06 cm) Depth 24.0 in. (60.96 cm) Rackmount 4 Gb Fibre Channel Point-to-Point Disk Expansion Chassis Width Depth Height 17.72 in (45.0 cm) 14.00 in. (35.56 cm) 5.25 in. (13.33 cm), 3 EIA units Weight 52.5 lb. (23.8 kg) max. Weight 68 lb. (30.9 kg) max. configuration Power Processor Chassis 4 Gb Fibre Channel Point-to-Point Disk Expansion Chassis DC Line Voltage -36 to -72 Vdc (Nominal -48V or -60V power systems) -36 to -72 Vdc (Nominal -48V or -60V power systems) DC Line Current 7.4 A max. at -36 Vdc, 5.5 A typ. at -48 Vdc 11.8 A max. at -36 Vdc, 8.9 A typ. at -48 Vdc Power Consumption 265 W max. 425 W max. Heat Dissipation 0.95 x 106 J/hr, (905 Btu/hr) max. 1.53 x 106 J/hr, (1,450 Btu/hr) max. Inrush Current 24 A peak, per requirements in EN300 132-2 Sect. 4.7 limit curve. 20 A peak, per requirements in EN300 132-2 Sect. 4.7 limit curve DC Protection 10 A fuse on each power supply 20 A fuse on each power supply DC Inlet Type Positronic Industries PLA06M4B0A1-436.0 Positronic Industries PLB3W3M1000 Mating DC Connector Positronic Industries PLA06F7050/AA Positronic Industries PLB3W3F7100A1 Ride-through Time 10 ms min. at -48 V input 10 ms min. at -48 V input Current Sharing 60% max., 40% min., between power supplies 60% max., 40% min., between power supplies Operating Environment Operating Temperature*: 41 to 104°F (5 to 40°C) up to 8,000 ft. (2,440 m) altitude Short-Term Operating Temperature**: 23 to 122°F (-5 to 55°C) up to 5,900 ft. (1,800 m) altitude Temperature Gradient: 54°F/hr (30°C/hr) Operating Relative Humidity: 5% to 85% Short-Term Relative Humidity**: 5% to 90%, not to exceed 0.024 kg water/kg of dry air Altitude Operational Altitude: 10,000 feet above sea level Transit Altitude: 25,000 feet above sea level *Maximum operating temperature shall be de-rated 1.1 degree C/1,000 feet above 7,500 feet. **Short-term refers to a period of not more than 96 consecutive hours and not more than 15 days in 1 year. (This is a total of 360 hours maximum, and not more than 15 occurrences in any given year.) Electromagnetic Emissions and Immunity FCC Class A EN55022 Class A CE Mark VCCI Class A (for Japan) ICES-003 Class A (for Canada) AS/NZS 3548 Class A (for Australia/New Zealand) EN55024 Immunity, ITEBSMI Class A (for Taiwan) Quality and Safety Standards UL 60950; CSAC 22.2-60950, FN 60950 NEBS Level 3 Certification EMC Corporation Hopkinton Massachusetts 01748-9103 1-508-435-1000 In North America 1-866-464-7381 ETSI EN 300 386 Manufactured under an ISO 9000-registered quality system EMC2, EMC, CLARiiON, FLARE, Navisphere, Symmetrix, PowerPath, VisualSAN, and where information lives are registered trademarks and SAN Manager, CLARalert, SnapView, MirrorView, and VisualSRM are trademarks of EMC Corporation. VMware is a registered trademark of VMware, Inc. Other trademarks are the property of their respective owners. © Copyright 2007 EMC Corporation. All rights reserved. Published in the USA. 07/07 Specification Sheet H2577.1 www.EMC.com