SZ-IO Stanza® Wireless Control Interfaces 369379 Rev. A 1 12.10.10 SZ-IO Contact Closure Interface Description The Stanza system is an easy-to-install and easy-to-use lighting control system designed especially for hotel guest rooms and similar applications. The system consists of wallbox dimmers, wallbox switches, line-voltage wallbox keypads, low-voltage interfaces, and lamp socket dimmer/switches. All of these devices communicate via radio frequency (RF) within each individual guest room. The Stanza contact closure interface allows Stanza systems to connect with equipment that has contactclosure inputs and outputs, including: – Occupancy and vacancy sensors. – Motorized window treatments. – AV equipment. – Thermostats. – Card switches. – Alarm systems. The functionality of the Stanza contact closure interface is determined by programming from the Stanza design graphical user interface (GUI) PC software. Features •Provides five inputs and five dry contact closure outputs. •Provides both normally open (NO) and normally closed (NC) momentary or maintained contacts. •Using the inputs, contact closures in other equipment can interface with the Stanza system to: – Select scenes. – Turn lights on or off based on room occupancy. – Generate contact closure outputs. •Using the outputs, contact closure inputs or button presses on keypads can: – Trigger outputs to control other equipment. – Provide status feedback to other equipment. •Provides 15 - 24 V , 100 mA maximum output for powering external devices, such as card switches and occupant sensors. •Up to 3 contact closure interfaces may be used in a basic Stanza system (limit can be increased with SZ-CI-PRG present). R SPECIFICATION SUBMIT T A L Job Name: Job Number: Model Numbers: Page 1 Wireless Control Interfaces SZ-IO Stanza® 369379 Rev. A 2 12.10.10 Specifications Standards: Five Output Terminals: •FCC approved. Complies with the limits for a Class B •Provide maintained or momentary (programmable digital device, pursuant to Part 15 of the FCC rules 0.25- to 20-second) outputs. •The SZ-IO is not rated to control unclamped, Input Power: inductive loads. Inductive loads include, but are not •Low-voltage PELV (Class 2: USA). limited to, relays, solenoids, and motors. To control Operating voltage: 15 - 24 V , 200 mA. these types of equipment, a flyback diode must be •AC adapter included (requires 120 V outlet; used (DC voltages only). See diagram below. provides 15 V output). Output Power: •The SZ-IO can support an external device drawing up to 100 mA. Note that the power is supplied directly from the external low-voltage PELV (Class 2: USA). Five Input Terminals: Flyback Diode Inductive Load NO + - NC DC SZ-IO Output •Accept maintained inputs and momentary inputs with 40 msec minimum pulse times. •Off-state leakage current must be less than 100 µA. •Open circuit voltage: 24 V maximum. •Relays are non-latching and de-energize if power is •Inputs must be dry contact closure, solid state, lost. open collector, or active-low (NPN)/active high •250 ft (76 m) maximum from interface to external (PNP) output. device. - Open collector NPN or active-low on-state •Output current is rated as follows: voltage must be less than 2 V and sink 3.0 mA. Resistive Supply Load Voltage - Open collector PNP or active-high on-state voltage must be greater than 12 V and 1.0 A 0 - 24 V source 3.0 mA. •250 ft (76 m) maximum from external device to 0.5 A 0 - 24 V interface R R SPECIFICATION SUBMIT T A L Job Name: Job Number: Model Numbers: Page 2 SZ-IO Stanza® Wireless Control Interfaces 369379 Rev. A 3 12.10.10 Specifications Key Design Features: •Five Status LEDs can be set to light when associated output or input is active (on) or closed. Additional status LEDs show proper device and system operation. •Power failure memory: if power is interrupted, when the power is restored, device will retain all settings that were in place prior to the interruption. •Diagnostic mode allows the outputs to be overridden temporarily. System Communications and Capacity: •Contact closure interface communicates with other Stanza system components through radio frequency (RF) at 434 MHz. •Multiple RF channels and thousands of system addresses prevent interference between systems. •Each contact closure interface counts as 1 device toward the basic system maximum of 31 RF devices (maximum devices can be increased to 100 if an SZ-CI-PRG is present in the system). •A maximum of three Stanza contact closures may be used per system (limit increases with SZ-CI-PRG present). Environment: •32-104 °F (0-40 °C). •Relative humidity less than 90% non-condensing. •Indoor use only. •Cannot be mounted in a metal enclosure (interferes with RF reception). Warranty: •1-year limited warranty •2-year full parts and labor warranty, with 8-year pro-rated parts replacement on commissioned systems For complete warranty details, see www.lutron.com/TechnicalDocumentLibrary/ Warranty_CommercialSystems.pdf Color/Finish: •Black only R SPECIFICATION SUBMIT T A L Job Name: Job Number: Model Numbers: Page 3 SZ-IO Stanza® Wireless Control Interfaces 369379 Rev. A 4 12.10.10 Dimensions Dimensions are in inches (mm). 2.47 (62.7) Mounting holes 6.0 (152.4) 4.26 (108.2) 3.75 (95.3) 0.25 (6.4) 0.18 (4.6) dia. 0.34 (8.6) dia. 1.0 (25.4) 5.26 (133.6) Terminal blocks on this side LEDs and DIP switches on this side #6 or #8 (M3 or M4) screw recommended (not included) 0.18 (4.6) dia. 1.06 (26.9) Mounting Diagram Mounting 1.Mount the control interface directly on a wall, as shown in the Mounting Diagram, using screws (not included). 2.When mounting, provide sufficient space for the antenna and connecting cables. 3.Mount in an accessible location for convenient access to addressing button, LEDs, terminal blocks, and DIP switches. 4.The unit cannot be mounted in a full metal enclosure. If mounting in a metal enclosure is necessary, antenna must fully protrude out of a knockout or other hole. The antenna is not removable or remotely mountable. 5.Connect wiring as shown in the Wiring Diagram. Use wire sizes as specified in the Wiring Diagram. 6.The SZ-IO should be mounted no less than 3 ft (1 m) from motorized window treatments for proper RF performance. 7.The SZ-IO must remain accessible after commissioning. 8.The SZ-IO must be connected to Earth/Ground or Chassis Ground for ESD protection (see Wiring Diagram). Wall 2.50 3.75 Control Interface Wire Strip Length 4.26 5.26 3/8 in (10 mm) 1.06 R SPECIFICATION SUBMIT T A L Job Name: Job Number: Model Numbers: Page 4 Wireless Control Interfaces SZ-IO Stanza® 369379 Rev. A 5 12.10.10 System Overview System Communication Notes Keypad Dimmer 30 ft (9 m) max. 30 ft (9 m) max. from repeater device Feature Maximum devices RS232 and/or Ethernet Interface Capability PC Required for Device Replacement 30 ft (9 m) max. from repeater device •Stanza RF devices must be located within 30 ft (9 m) of a Stanza RF device configured as a repeater. Multiple devices configured as repeaters may be necessary to provide adequate coverage. •Any Stanza RF device can be configured as a repeater. •A total of 5 devices maximum can be configured as repeaters. •Devices configured as repeaters must be within 30 ft (9 m) of another device configured as a repeater. •Stanza lighting controls cannot be controlled wirelessly, and Stanza keypads and contact closure interfaces will not function, until they are addressed and programmed. Basic System (no SZ-CI-PRG present) 31 No Advanced System (with SZ-CI-PRG present) 100 Yes No Yes Interface Overview Antenna SZ-IO Addressing button LED LED LED LED LED LED LED 1234567 PELV (Class 2: USA) Power In 15 - 24 V 200 mA 1: CCI/O 1 status 2: CCI/O 2 status 3: CCI/O 3 status 4: CCI/O 4 status 5: CCI/O 5 status 6: Addressing mode 7: RF link activity DIP Switches Note: Device should be powered using the supplied transformer or shade power supply (Lutron® part number SZ-PS-P1-1-50). See Wiring Diagram. Contact Lutron Technical Support prior to powering device using any other transformer or power supply. R SPECIFICATION SUBMIT T A L Job Name: Job Number: Model Numbers: Page 5 Wireless Control Interfaces SZ-IO Stanza® 369379 Rev. A 6 12.10.10 Wiring Diagram Contact Closure Inputs CCO 1 NC CCO 1 NO 1-2 COM CCO 2 NC CCO 2 NO CCO 3 NC CCO 3 NO 3-4 COM CCO 4 NC CCO 4 NO CCO 5 NC CCO 5 NO 5 COM CCI 1 CCI 2 CCI 3 CCI 4 CCI 5 COM +PWR OUT COM GND N/C Contact Closure Outputs 15 - 24 V 200 mA Power terminals each hold two 18 AWG (1.0 mm2) wires CCI and CCO terminals each hold one 28 - 16 AWG (0.08 - 1.5 mm2) wire Note: For ESD protection, the included ground wire should be connected to Earth/Ground before device is powered. Operation The SZ-IO receives its operating settings during system startup. A device database containing settings is transferred to the SZ-IO after it has been addressed. This database includes settings for: • CCO behavior (maintained vs. momentary) • Momentary pulse time • CCI programming action • System presets LED Feedback The SZ-IO provides 7 LEDs for user feedback: Status LEDs LEDs 1 through 5 provide feedback for the CCOs and CCIs. The display mode (CCO vs. CCI status) depends on the position of DIP switch 7: The LED lights when the CCO is active or when the CCI is closed. Switch up (on): CCI status displayed Switch down (off): CCO status displayed Addressing Mode LED LED 6 will blink during addressing. A slow blink (on for 3 seconds every 4 seconds) indicates an unaddressed device. A fast blink (once per second) indicates an addressed device. When not in addressing mode, this LED is off. RF Link Activity LED LED 7 will blink when the SZ-IO receives or transmits an RF packet. R SPECIFICATION SUBMIT T A L Job Name: Job Number: Model Numbers: Diagnostic Mode and DIP Switch Settings Diagnostic mode allows the user to override the contact closure outputs (CCOs) of the device. DIP Switch Settings Switch # 6 7 Mode LED Display Shows Normal Outputs Normal Inputs Diagnostic Outputs Switch up (On) Switch down (Off) Note: In diagnostic mode, DIPs 1-5 set the override state of the outputs. Diagnostic Mode Operation 1. Enter diagnostic mode. Move DIP switch 6 to the on (up) position. LEDs 6 and 7 will flash together (once per second) while the unit is in diagnostic mode. 2. Select CCOs to override. Use DIP switches 1 through 5 to select which CCOs to close when the addressing (ADDR) button is pressed. (The DIP switch number corresponds to the CCO it controls.) 3. Activate the CCOs. Press the addressing button to activate the CCOs you set using the DIP switches in the previous step. The CCOs will remain active as long as the button is pressed. 4. Exit diagnostic mode. Move DIP switch 6 to the off (down) position. LEDs 6 and 7 will stop flashing together. Page 6 Wireless Control Interfaces SZ-IO Stanza® 369379 Rev. A 7 12.10.10 Wiring Examples } Stanza card switch (rear view) Common +PWR COM GND N/C Wiring to Stanza® Card Switch Available CCIs (any available CCI can be used) SZ-IO Rear View 4: CCI Common 3: CCI 1: Common 2: Power 15 – 24 V Wiring to Stanza® Contact Closure Shade Note: Power supplied to SZ-IO by plug-in wall transformer on the other side of the unit. Available CCOs (any available CCO can be used) Lutron® motorized window treatment power supply } GND N/C +PWR COM N/C 24 V COM Note: The SZ-IO should be mounted no less than 3 ft (1 m) from motorized window treatments for proper RF performance. SZ-IO Rear View To second EDU (if present) Terminal block of shade or drape EDU COM 24 V Close Open Lutron contact closure drapery track system electronic drive unit (EDU) Note: When wiring to Lutron contact closure shade as shown, power is provided to the SZ-IO by the window treatment power supply. In this case, a separate plug-in wall transformer should not be used for the SZ-IO. Available CCIs } Common Available CCOs } +PWR COM GND N/C Wiring to/from Equipment by Others Note: Power supplied to SZ-IO by plug-in wall transformer on the other side of the unit (not shown). SZ-IO Rear View For powering equipment by others 15 - 24 V 100 mA max available from plugin supply on front panel. R To CCI equipment by others SPECIFICATION SUBMIT T A L Job Name: Job Number: Model Numbers: From CCO equipment by others Page 7