Reinforcing Mesh Product Guide

advertisement
Reinforcing Mesh
Product Guide
“Reinforcing New Zealand since 1954”
Super Ductile 500E & Hard Drawn
www.fletcherreinforcing.co.nz
Contents
Fletcher Reinforcing
New Zealand Standards
Equivalent mesh to the 66x sizing
Mesh summary
Super Ductile 500E Specifications
Hard Drawn Mesh Specifications
Mesh Smart-phone App
www.fletcherreinforcing.co.nz
Fletcher Reinforcing supplies the reinforcing steel and mesh
that provides the strength to New Zealand‟s buildings and
infrastructure. Mesh is available from national Building
Merchants or our branch network to construction sites and
builders throughout New Zealand.
Fletcher Reinforcing offer a range of New Zealand
manufactured mesh that complies and is tested to all current
Standards. The range covers both Super Ductile mesh in
grade 500E wire and a proven range of hard drawn mesh in
the sizes required by builders and contractors throughout New
Zealand.
The Department of Building & Housing now states the reinforcing requirements for concrete slabs-onground of buildings built in accordance with NZS 3604: 2011, have a minimum of 2.27 kg/m2 of Grade
500E reinforcing mesh fabric which conforms with AS/NZS4671:2001. Super Ductile 500E meets these
requirements:
Grade 500E (seismic) as per AS/NZS 4671:2001
Yield stress (MPa) >500 <600
Uniform Elongation >10%
Tensile Ratio % >1.15 <1.40
Weight per m2 complies with NZS 3604:2011 (min 2.27kg/m2)
Weld Shear Strength >5.9 kN
External testing is completed by SGS, the world‟s leading inspection, verification, testing &
certification company
Hard drawn mesh is specified under NZ3421:1975 (see next page for more detail). Fletcher Reinforcing
offers a range of mesh sheet sizes and centres to meet the needs of typical New Zealand applications.
Our range covers standard sheet sizes of 4.65m x 1.97m through to our larger economical sheets which
are 6.15m x 2.42m. Centres are either 150 x150mm or the „step through‟ option of 300 x 300mm.
www.fletcherreinforcing.co.nz
New Zealand Standards
Standards New Zealand controls the preparation and publishing of all Standard Specifications and
Codes of Practice in New Zealand. They are developed by expert committees using a consensus-based
process that facilitates public input. The relevant Standards listed below, specify the mechanical
properties of the steel wire used for concrete reinforcement, the fabrication of the welded fabric and the
methods of application in respect to concrete reinforcement.
Visit www.standards.co.nz for more information.
NZ3421:1975
Specification for Hard Drawn Mild Steel Wire for Concrete Reinforcement
The Standard requires the following tensile properties:NOMINAL DIAMETER
(mm)
MINIMUM 0.2%
PROOF
STRESS (MPa)
Up to and including 3.15
Over 3.15
TENSILE STRENGTH (MPa)
Minimum
Maximum
485
575
855
485
575
775
NZ3422:1975
Specification for Welded Fabric of Drawn Steel Wire for Concrete Reinforcement
This Standard requires a minimum average Weld Shear load “Where the longitudinal wire diameter is in
the range 11mm to 3.15mm and the longitudinal to transverse wire diameter differential does not exceed
3mm, the minimum average shear value in Newtons shall be not less than 240 multiplied by the
cross-sectional area of the longitudinal wire in square millimetres”, and states requirements of “The
distance between centres of two adjacent wires shall not vary by more than 7.5 percent from the exact
pitch”. “If fabric is required to be cut to specific dimensions, the tolerance shall be as follows”:
5 Metres and under
+25mm
over 5 metres
+0.5%
NZS3101:2006
Code of Practice for The Design of Concrete Structures
This Standard lays out the development length and lap-splice requirements for plain wire mesh and
deformed wire mesh, and is the basis of any pertinent calculations or recommendations given in this
Product Guide.
www.fletcherreinforcing.co.nz
Hard Drawn Mesh Equivalents
Standard
Equivalent Centres Wire Ø
668
665
663
662
661
150
150
150
150
150
4.0
5.3
6.3
7.1
7.5
Economical
Length
Width
(mm)
(mm)
4650
4650
4650
1970
1970
1970
Nett
Fletcher
Cover Reinforcing
(m2)
Item
7.525
7.525
7.525
668L
665L
663L
Length
Width
Nett
Cover
(mm)
(mm)
(m2)
Fletcher
Reinforcing
Item
6150
6150
6150
6150
2420
2420
2400
2400
12.760
12.760
12.285
12.285
665E
663E
662E
661E
300 Centres
Equivalent Centres Wire Ø
668
665
300
300
5.6
7.5
Length
Width
(mm)
(mm)
4950
4950
2220
2220
Nett
Fletcher
Cover Reinforcing
(m2)
Item
10.08
10.08
84/10
147/10
Equivalents are based on the nominal sectional area of steel per metre width
* Note:
Additional meshes are available as a special order. Minimum order quantities will apply.
Please contact your local Fletcher Reinforcing Branch for further details
Super Ductile 500E Mesh Equivalents
What does SE62 mean?
Equivalent Centres Wire Ø
665
665
665
664
662
661
200
200
300
200
200
200
6.1
6.1
7.5
7.0
8.0
9.0
Length
Width
(mm)
(mm)
5050
5850
6050
6100
6100
6100
2020
2420
2420
2440
2440
2440
Nett
Fletcher
Cover Reinforcing
(m2)
Item
8.312
11.93
11.58
12.76
12.76
12.76
SE62Res
SE62
SE73
SE72
SE82
SE92
AS/NZS 4671:2001 designates
letters to be used to identify welded
mesh products:
S = Square (shape of grid centres)
E = Seismic grade (Earthquake)
6 = 6mm wire
2 = 200mm centres
Equivalents are based on the nominal sectional area of steel per metre width
www.fletcherreinforcing.co.nz
Hard drawn wire mesh
Super Ductile wire mesh
485 Mpa
Min: 500 MPa Max: 600MPa
Wire
Cross
Wire
Cross
Description Diameter Centres
Mass
Section
per m
Industry
2
Equivalents Description Diameter Centres
mm
mm
mm 2/m
kg/m 2
668L
84/10
4.0
5.6
150
300
83.8
82.1
1.315
1.289
668
668
665L
665E
147/10
5.3
5.3
7.5
150
150
300
147.1
147.1
147.3
2.309
2.309
2.312
665
665
665
664
Mass
Section
per m2
mm
mm
mm 2/m
kg/m 2
SE62Res
SE62
SE73
6.1
6.1
7.5
200
200
300
146.1
146.1
147.3
2.294
2.294
2.312
SE72
7.0
200
192.0
3.02
663L
663E
6.3
6.3
150
150
207.8
207.8
3.263
3.263
663
663
662E
7.1
150
263.9
4.144
662
SE82
8.0
200
251.0
3.95
661E
7.5
150
294.5
4.624
661
SE92
9.0
200
318.0
4.99
Equivalents are based on the nominal sectional area of steel per metre width
* Note:
Additional meshes are available as a special order. Minimum order quantities will apply.
Please contact your local Fletcher Reinforcing Branch for further details
www.fletcherreinforcing.co.nz
SE62 Res
Seismic Grade Reinforcing Mesh
Mesh Specification
Product Description: 5.05m x 2.02m — 200 x 200 Grid R6.1 Line Wire, R6.1 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
6.1 R
200
5050
11
25
25
146.1
0.2294
12.74
Cross Wire
6.1 R
200
2020
26
10
10
146.1
0.2294
12.05
GROSS SHEET WEIGHT (Kg):
24.79
MASS PER SQ METER (Kg/m2):
2.294
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
10.201
NETT COVER (m2):
8.312
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.0933
BUNDLE WEIGHT (Tonnes):
0.6198
MECHANICAL PROPERTIES
Yield Strength
Tensile Ratio
Uniform
Elongation %
Min
Max
Min
Max
Weld Shear
Strength
≥ 10%
500MPa
600MPa
1.15
1.4
> 5.9
Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001. All Super Ductile 500E product is
Individually tagged . The tag contains the product code and the unique batch number relevant to the sheet. It is important that
this tag is kept in position to allow easy identification until covered with concrete.
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
SE62
Seismic Grade Reinforcing Mesh
Mesh Specification
Product Description: 5.85m x 2.42m — 200 x 200 Grid R6.1 Line Wire, R6.1 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
6.1 R
200
5850
13
25
25
146.1
0.2294
17.45
Cross Wire
6.1 R
200
2420
30
10
10
146.1
0.2294
16.65
GROSS SHEET WEIGHT (Kg):
34.10
MASS PER SQ METER (Kg/m2):
2.294
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
14.157
NETT COVER (m2):
11.932
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
2.2453
BUNDLE WEIGHT (Tonnes):
0.8525
MECHANICAL PROPERTIES
Yield Strength
Tensile Ratio
Uniform
Elongation %
Min
Max
Min
Max
Weld Shear
Strength
≥ 10%
500MPa
600MPa
1.15
1.4
> 7.3
Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001. All Super Ductile 500E product is
Individually tagged . The tag contains the product code and the unique batch number relevant to the sheet. It is important that
this tag is kept in position to allow easy identification until covered with concrete.
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
SE73
Seismic Grade Reinforcing Mesh
Mesh Specification
Product Description: 6.05m x 2.42m — 300 x 300 Grid R7.5 Line Wire, R7.5 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
7.5 R
300
6050
9
25
25
147.3
0.3468
18.88
Cross Wire
7.5 R
300
2420
21
10
10
147.3
0.3468
17.62
GROSS SHEET WEIGHT (Kg):
36.51
MASS PER SQ METER (Kg/m2):
2.312
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
14.641
NETT COVER (m2):
11.582
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
2.8550
BUNDLE WEIGHT (Tonnes):
0.9127
MECHANICAL PROPERTIES
Yield Strength
Tensile Ratio
Uniform
Elongation %
Min
Max
Min
Max
Weld Shear
Strength
≥ 10%
500MPa
600MPa
1.15
1.4
> 11.0
Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001. All Super Ductile 500E product is
Individually tagged . The tag contains the product code and the unique batch number relevant to the sheet. It is important that
this tag is kept in position to allow easy identification until covered with concrete.
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
668L
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 4.65m x 1.97m — 150 x 150 Grid D4.0 Line Wire, D4.0 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
4.0 D
150
4650
14
75
75
83.8
0.0986
6.42
Cross Wire
4.0 D
150
1970
31
10
10
83.8
0.0986
6.02
GROSS SHEET WEIGHT (Kg):
12.44
MASS PER SQ METER (Kg/m2):
1.315
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
9.161
NETT COVER (m2):
7.525
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.0550
BUNDLE WEIGHT (Tonnes):
0.3110
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
665L
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 4.65m x 1.97m — 150 x 150 Grid D5.3 Line Wire, D5.3 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
5.3 D
150
4650
14
75
75
147.1
0.1732
11.28
Cross Wire
5.3 D
150
1970
31
10
10
147.1
0.1732
10.58
GROSS SHEET WEIGHT (Kg):
21.85
MASS PER SQ METER (Kg/m2):
2.309
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
9.161
NETT COVER (m2):
7.525
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.0728
BUNDLE WEIGHT (Tonnes):
0.5463
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
663L
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 4.65m x 1.97m — 150 x 150 Grid D6.3 Line Wire, D6.3 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
6.3 D
150
4650
14
75
75
207.8
0.2447
15.93
Cross Wire
6.3 D
150
1970
31
10
10
207.8
0.2447
14.94
GROSS SHEET WEIGHT (Kg):
30.87
MASS PER SQ METER (Kg/m2):
3.263
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
9.161
NETT COVER (m2):
7.525
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.0866
BUNDLE WEIGHT (Tonnes):
0.7719
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
665E
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 6.15m x 2.42m — 150 x 150 Grid D5.3 Line Wire, D5.3 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
5.3 D
150
6150
17
75
75
147.1
0.1732
18.11
Cross Wire
5.3 D
150
2420
41
10
10
147.1
0.1732
17.18
GROSS SHEET WEIGHT (Kg):
35.29
MASS PER SQ METER (Kg/m2):
2.309
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
14.883
NETT COVER (m2):
12.76
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.1183
BUNDLE WEIGHT (Tonnes):
0.8823
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
663E
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 6.15m x 2.42m — 150 x 150 Grid D6.3 Line Wire, D6.3 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
6.3 D
150
6150
17
75
75
207.8
0.2447
25.58
Cross Wire
6.3 D
150
2420
41
10
10
207.8
0.2447
24.28
GROSS SHEET WEIGHT (Kg):
49.86
MASS PER SQ METER (Kg/m2):
3.263
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
14.883
NETT COVER (m2):
12.76
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.1406
BUNDLE WEIGHT (Tonnes):
1.2466
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
662E
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 6.15m x 2.4m — 150 x 150 Grid D7.1 Line Wire, D7.1 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
7.1 D
150
6150
14
150
150
263.9
0.3108
26.76
Cross Wire
7.1 D
150
2400
40
150
300
263.9
0.3108
29.84
GROSS SHEET WEIGHT (Kg):
56.60
MASS PER SQ METER (Kg/m2):
4.144
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
14.76
NETT COVER (m2):
12.285
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.2096
BUNDLE WEIGHT (Tonnes):
1.4149
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
661E
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 6.15m x 2.4m — 150 x 150 Grid D7.5 Line Wire, D7.5 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
mm2/m
Wire kg/m Weight (kg)
Longitudinal Wire
7.5 D
150
6150
14
150
150
294.5
0.3468
29.86
Cross Wire
7.5 D
150
2400
40
150
300
294.5
0.3468
33.29
GROSS SHEET WEIGHT (Kg):
63.15
MASS PER SQ METER (Kg/m2):
4.624
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
14.76
NETT COVER (m2):
12.285
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.2214
BUNDLE WEIGHT (Tonnes):
1.2630
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
84/10
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 4.95m x 2.22m — 300 x 300 Grid D5.6 Line Wire, D5.6 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
Longitudinal Wire 1
5.6 D
300
4950
6
25
25
Longitudinal Wire 2
4.0 D
50
4950
4
25
25
Cross Wire
5.6 D
300
2220
19
10
10
mm2/m
Wire kg/m Weight (kg)
82.1
0.1933
5.74
0.0986
1.95
0.1933
8.15
GROSS SHEET WEIGHT (Kg):
15.85
MASS PER SQ METER (Kg/m2):
1.289
82.1
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
10.989
NETT COVER (m2):
10.08
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.0923
BUNDLE WEIGHT (Tonnes):
0.3962
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
147/10
Hard Drawn Reinforcing Mesh
Mesh Specification
Product Description: 4.95m x 2.22m — 300 x 300 Grid D7.5 Line Wire, D7.5 Cross Wire
Wire Dia. (mm) Spacing (mm)
Length (mm)
No. of Wires
Overhangs (mm)
Longitudinal Wire 1
7.50 D
300
4950
6
25
25
Longitudinal Wire 2
5.30 D
50
4950
4
25
25
Cross Wire
7.50 D
300
2220
19
10
10
mm2/m
Wire kg/m Weight (kg)
147.3
0.3468
10.30
0.1732
3.43
0.3468
14.63
GROSS SHEET WEIGHT (Kg):
28.36
MASS PER SQ METER (Kg/m2):
2.312
147.3
MESH SKETCH (not to scale)
GROSS SHEET AREA (m2):
10.989
NETT COVER (m2):
10.08
Ratio STACK & TURNED (Y/N):
No. OF SHEETS / BUNDLE:
Y
25
ESTIMATED CUBIC (m3):
0.1236
BUNDLE WEIGHT (Tonnes):
0.7089
MECHANICAL PROPERTIES
Wire Diam
Uniform
Elongation %
0.2% Proof Stress
Min
> 5.0mm
≥ 1.5%
485MPa
≥ 5.0mm
≥ 1.5%
485MPa
Max
Ratio
Rm / Re
≥ 1.03%
750MPa
≥ 1.03%
* All measurements/weights approximate
Mesh App:
Download our free smart-phone
app by visiting the Apple or
Google stores. Alternatively,
scan the QR code from your
phone to download directly.
www.fletcherreinforcing.co.nz
Overview
The Fletcher Reinforcing Smart Phone App is designed to
offer you immediate access to the information you need
about our ranges of Super Ductile and Hard Drawn meshes.
This Guide will outline how to access this information quickly
and easily.
Downloading
Available for both the Apple iPhone and all Android
phones, the free download can be accessed through the
Apple App Store and the Android Market. Just search for
“Fletcher Reinforcing”
Alternatively, scan this QR Code from your phone to be
taken to the appropriate download:
Current Devices
The App is currently available for:
iPhone
Android phones
iPad (not optimised)
www.fletcherreinforcing.co.nz
Download