aabcefghicd drywall trimless - installation instructions

advertisement
SKIM
1
DRYWALL TRIMLESS - INSTALLATION INSTRUCTIONS
3
2
SINGLE FIXTURE
W W W . L U M E N W E R X . C O M
C
*
*
A
A
B
Prepare the area and mark the mounting point
location where the fixture is going to be installed
according to the dimensions [*] in the client
drawings.
Locate wall bracket (A) position using provided
client drawing. Install wall bracket to wall. Align
with structural stud or use drywall anchors when
needed.
Remove lens (B) from the fixture (C).
4
5
6
F
G
H
I
D
C
E
Disconnect LED molex connector (D) by taking a
pointed object and pressing on the two tabs on the
top.
Unscrew and remove the cartridge (E) from the
fixture.
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC.
Install power cable (F) (by other) through the BX
connector (G) (by other) and install onto the power
plate (H) provided. Make electrical connections
between power cable (F) and fixture cables using
electrical marettes (I). Reinstall the power plate
(H) to the fixture (C).
FILE NAME:SKIM.DRYWALL.TRIMLESS.INST
LumenWerx ULC. reserves the right to change or modify product specifications without notification
November 3, 2015
Page: 1 / 4
DRYWALL TRIMLESS - INSTALLATION INSTRUCTIONS
W W W . L U M E N W E R X . C O M
7
9
8
J
K
L
+
_
SKIM
D
C
C
E
A
Insert fixture (C) into pre-cut hole in drywall,
aligning threaded rods (J) with holes in top of
fixture (C). Put washers (K) and tighten nuts (L) to
secure the fixture (C).
10
Insert fixture (C) into wall bracket (A), adjustable
of 1/4”.
Reconnect the LED connector (D) to the cartridge
(E). Reinstall the cartridge (E).
11
12
CONTINUOUS SYSTEM
*
*
A
*
A
B
Reinstall the lens (B).
Prepare the area and mark the mounting point
location where the fixture is going to be installed.
according to the dimensions [*] in the client
drawings.
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC.
Locate wall bracket (A) position using provided
client drawing. Install wall brackets to wall. Align
with structural stud or use drywall anchors when
needed.
FILE NAME:SKIM.DRYWALL.TRIMLESS.INST
LumenWerx ULC. reserves the right to change or modify product specifications without notification
November 3, 2015
Page: 2 / 4
SKIM
DRYWALL TRIMLESS - INSTALLATION INSTRUCTIONS
13
W W W . L U M E N W E R X . C O M
15
14
D
E
B
Remove lens (B) from all the fixtures in the run.
16
Disconnect LED molex connector (D) by taking a
pointed object and pressing on the two tabs on the
top.
17
F
Unscrew and remove the cartridges (E) from all
the fixtures in the run.
18
J
K
L
G
H
C
I
C
Install power cable (F) (by other) through the BX
connector (G) (by other) and install onto the power
plate (H) provided. Make electrical connections
between power cable (F) and first fixture cables
using electrical marettes (I). Reinstall the power
plate (H) to the first fixture (C).
C
A
Insert the first fixture (C) into pre-cut hole in
drywall, aligning threaded rods (J) with holes in
top of fixture (C). Put washers (K) and tighten nuts
(L) to secure the fixture (C).
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC.
Insert the first fixture (C) into wall bracket (A),
adjustable of 1/4”.
FILE NAME:SKIM.DRYWALL.TRIMLESS.INST
LumenWerx ULC. reserves the right to change or modify product specifications without notification
November 3, 2015
Page: 3 / 4
SKIM
19
DRYWALL TRIMLESS - INSTALLATION INSTRUCTIONS
O
20
C
W W W . L U M E N W E R X . C O M
21
J
K
L
M
O
M
N
A
22
_
Make wires connection between (C) and (M) using
quick connectors (N).
Insert the second fixture (M) into pre-cut hole in
drywall, aligning threaded rods (J) with holes in
top of fixture (M) and the second fixture with the
joining brackets (O). Put washers (K) and tighten
nuts (L) to secure the fixture (M).
23
D
Insert the second fixture (M) into wall bracket
(A),adjustable of 1/4”.
24
+
M
O
E
P
B
E
Tighten the set screws (P) on both joining brackets
(O) using Allen Key to secure the fixtures together.
B
Reconnect the LED connector (D) to the cartridges
(E). Reinstall the cartridges (E).
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC.
Reinstall the lenses (B) on all the fixtures.
FILE NAME:SKIM.DRYWALL.TRIMLESS.INST
LumenWerx ULC. reserves the right to change or modify product specifications without notification
November 3, 2015
Page: 4 / 4
Download