Ordering Information Cases • • • • • • Time delay on pick up or delay on drop off Rated voltage Setting range Contact combination Whether flag indication required Case size Type MDDA relay can be provided either in size 2/3 or 1 vedette drawout case or in 3N non-draw-out case (AC relay can be provided in size 1 vedette only) Qualification ISO 9001-2000 PART 01 02 04 CASE SIZE 2/3V 1V 3N CUT OUT A B 149.5 148 221 148 104 140 BEZEL C D 170 170 243 170 128 170 The policy of Easun Reyrolle is one of continuous improvement and development. The company therefore reserves the right to supply equipment, which may differ slightly from that described and illustrated in this publication. CORPORATE OFFICE Easun Reyrolle Limited., 98 Sipcot Industrial Complex Hosur 635 126, India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 TURNKEY PROJECTS BUSINESS/AMR BUSINESS #389, “Rasukumaki”, Hulimavu Begur Hobli, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 40477200/ 201 Fax: +91 80 40477202 Email: cenmarket@easunreyrolle.net HOSUR WORKS #98, Sipcot Industrial Complex Hosur - 635 126, India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 CENTRAL MARKETING & EXPORTS BUSINESS #17/3 Arakere Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: cenmarket@easunreyrolle.net BANGALORE WORKS #17/3 Arakere, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: blrworks@easunreyrolle.net AUTOMATION BUSINESS #389, “Rasukumaki”, Hulimavu Begur Hobli, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 40477200/ 201 Fax: +91 80 40477202 Email: smabp@easunreyrolle.net ®Easun Reyrolle-2007 - Easun Reyrolle, the Easun Reyrolle logo and any alternative version thereof are registered trade marks and service marks of Easun Reyrolle Note: 1. All dimensions are in mm 2. All dimensions are measured equidistant from centre line 3. Maximum depth of equipment inside panel : 200mm Cutout Details MDDA Definite Time Lag Relay Description Applications Type MDDA relay consists of a power supply unit, a timer unit and an attracted armature auxiliary relay. Resistor and Zener diode combination of the power supply unit provides low voltage stabilised DC supply to the static timer circuit. Non-linear resistors are used in the power supply unit for surge suppression. The timer unit consists of a timer circuit and a thumb wheel switch. The thumb wheel switch mounted on the name plate of the relay provides precise and high resolution time setting. The timer unit operates a reed relay which in turn energises an attracted armature auxiliary relay. This auxiliary relay is provided to achieve higher contact rating and flag indication, if required. Type MDDA is a Definite Time Lag that can be used for applications where an accurate and consistent time-delay operation is required. MDDA can be provided either as a delay on pick up relay or as a delay on drop-off relay. A normally open contact is used for initiating time delay on pick up relay and output element gets energised after the set time delay. In the case of delay on drop off relay, the output element is normally energised and with the normally closed initiating contact opening out, the output elements gets de-energised after the set time delay. Sales Offices Kolkata Easun Reyrolle Ltd. 4, Dr.Sundari Mohan Avenue, 5th Floor Flat No.18, Kolkata - 700 014, India. Tel: +91 33 22848320 Fax: +91 33 22848326 Email: kolkata@easunreyrolle.net Bhopal Easun Reyrolle Ltd. H.No.16, Essarjee Homes Near Gopal Nagar, Kalan Road Piplani, Bhopal - 462 021, India. Telefax: +91 755 2684221 Email: bhopal@easunreyrolle.net Chennai Easun Reyrolle Ltd. 6th Floor, Temple Tower, 672, Anna Salai, Nandanam Chennai - 600 035, India. Tel: +91 44 24346425/24347608 Fax: +91 44 24346435 Email: chennai@easunreyrolle.net Mumbai Secunderabad Easun Reyrolle Ltd. Easun Reyrolle Ltd. 23, Kasturi Building, Jamshedji Tata Road #2, 1st Floor, Paradise Chambers Mumbai - 400 020, India. Opp Hotel Ambassador Tel: +91 22 22022270/22855415 1-7-196 Prender Ghast Road Fax: +91 22 22825703 Secunderabad - 500 003, India. Email: mumbai@easunreyrolle.net Telefax: +91 40 27817847 Email: hyderabad@easunreyrolle.net Delhi Easun Reyrolle Ltd. 29/12, Ground Floor, East Patel Nagar New Delhi - 110 008, India. Tel: +91 11 25747321/25747322 Fax: +91 11 25747320 Email: delhi@easunreyrolle.net Definite Time Lag Relay - MDDA Corporate Office Easun Reyrolle Limited. 98 Sipcot Industrial Complex, Hosur 635 126 India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 www.easunreyrolle.com FACTMDDA/08-07/REV 1 Bangalore Easun Reyrolle Ltd. #17/3 Arakere, Bannerghatta Road, Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: blroffice@easunreyrolle.net Technical Information Wiring Diagram 0.1 sec.-9.9 secs In steps of 0.1 sec* 0.1 sec.-29.9 secs in steps of 0.1 sec* 1 sec.-99 secs In steps of 1 sec* 1 sec.-299 secs in steps of 1 sec* *Selection by means of thumb wheel switches Contact Arrangement Time Settings Contact Rating Voltage rating: DC 24V 30V 48V 110V 220V Typical Wiring Diagram for MDDA Relay AC 110V 240V - The relay will operate satisfactorily between 80% and 120% of rated voltage. Relays rated for 48V DC and above will be provided with an external resistor. Flag Indicator Burden Insulation Rated DC Voltage in volts 24 30 48 110 220 Max.Burden at rated Voltage in watts 5 6 7 12 23 Burden of AC relays will be furnished on request Basic Accuracy : At rated voltage and at 200C ambient the time delay will be within + 5% of setting or + 10 milli-seconds whichever is greater. Repeat Accuracy : The variation in time delay will be less than +1% with 200 milli-seconds between sequential operations. Effect on Accuracy : The variation in time delay over the with DC supply voltage range will be less with variation than + 5% of the value at the rated supply voltage. Effect on Accuracy : Variation from time delay at 200C will with Temperature be less than + 5% over the variation temperature range-100C to + 550C. : The relay can be provided with a maximum of 4 pairs of self or hand reset contacts in any combination of make and break with a maximum of 2-break contacts. : The contacts can make and carry 1500VA AC or 1500W DC within the under mentioned limits: Voltage : 660V Current : 3A continuously 8A for 3 secs or 16A for 1 sec The contacts can break 300VA AC or 75W DC (inclusive L/R=0.04) within the limits of 250V and 5A. : A hand reset flag indicator can be provided on the output auxiliary relay, if required. 2.0 KV rms for 1 min between all terminals & earth. 2.0 KV rms for 1 min between independent circuits 1.0 KV rms for 1 min across normally open contacts. Transient Overvoltage 5KV, 1.2/50µs, 0.5joules between all terminals and earth or between any two terminals without damage or flash over. Technical Information Wiring Diagram 0.1 sec.-9.9 secs In steps of 0.1 sec* 0.1 sec.-29.9 secs in steps of 0.1 sec* 1 sec.-99 secs In steps of 1 sec* 1 sec.-299 secs in steps of 1 sec* *Selection by means of thumb wheel switches Contact Arrangement Time Settings Contact Rating Voltage rating: DC 24V 30V 48V 110V 220V Typical Wiring Diagram for MDDA Relay AC 110V 240V - The relay will operate satisfactorily between 80% and 120% of rated voltage. Relays rated for 48V DC and above will be provided with an external resistor. Flag Indicator Burden Insulation Rated DC Voltage in volts 24 30 48 110 220 Max.Burden at rated Voltage in watts 5 6 7 12 23 Burden of AC relays will be furnished on request Basic Accuracy : At rated voltage and at 200C ambient the time delay will be within + 5% of setting or + 10 milli-seconds whichever is greater. Repeat Accuracy : The variation in time delay will be less than +1% with 200 milli-seconds between sequential operations. Effect on Accuracy : The variation in time delay over the with DC supply voltage range will be less with variation than + 5% of the value at the rated supply voltage. Effect on Accuracy : Variation from time delay at 200C will with Temperature be less than + 5% over the variation temperature range-100C to + 550C. : The relay can be provided with a maximum of 4 pairs of self or hand reset contacts in any combination of make and break with a maximum of 2-break contacts. : The contacts can make and carry 1500VA AC or 1500W DC within the under mentioned limits: Voltage : 660V Current : 3A continuously 8A for 3 secs or 16A for 1 sec The contacts can break 300VA AC or 75W DC (inclusive L/R=0.04) within the limits of 250V and 5A. : A hand reset flag indicator can be provided on the output auxiliary relay, if required. 2.0 KV rms for 1 min between all terminals & earth. 2.0 KV rms for 1 min between independent circuits 1.0 KV rms for 1 min across normally open contacts. Transient Overvoltage 5KV, 1.2/50µs, 0.5joules between all terminals and earth or between any two terminals without damage or flash over. Ordering Information Cases • • • • • • Time delay on pick up or delay on drop off Rated voltage Setting range Contact combination Whether flag indication required Case size Type MDDA relay can be provided either in size 2/3 or 1 vedette drawout case or in 3N non-draw-out case (AC relay can be provided in size 1 vedette only) Qualification ISO 9001-2000 PART 01 02 04 CASE SIZE 2/3V 1V 3N CUT OUT A B 149.5 148 221 148 104 140 BEZEL C D 170 170 243 170 128 170 The policy of Easun Reyrolle is one of continuous improvement and development. The company therefore reserves the right to supply equipment, which may differ slightly from that described and illustrated in this publication. CORPORATE OFFICE Easun Reyrolle Limited., 98 Sipcot Industrial Complex Hosur 635 126, India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 TURNKEY PROJECTS BUSINESS/AMR BUSINESS #389, “Rasukumaki”, Hulimavu Begur Hobli, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 40477200/ 201 Fax: +91 80 40477202 Email: cenmarket@easunreyrolle.net HOSUR WORKS #98, Sipcot Industrial Complex Hosur - 635 126, India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 CENTRAL MARKETING & EXPORTS BUSINESS #17/3 Arakere Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: cenmarket@easunreyrolle.net BANGALORE WORKS #17/3 Arakere, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: blrworks@easunreyrolle.net AUTOMATION BUSINESS #389, “Rasukumaki”, Hulimavu Begur Hobli, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 40477200/ 201 Fax: +91 80 40477202 Email: smabp@easunreyrolle.net ®Easun Reyrolle-2007 - Easun Reyrolle, the Easun Reyrolle logo and any alternative version thereof are registered trade marks and service marks of Easun Reyrolle Note: 1. All dimensions are in mm 2. All dimensions are measured equidistant from centre line 3. Maximum depth of equipment inside panel : 200mm Cutout Details MDDA Definite Time Lag Relay Description Applications Type MDDA relay consists of a power supply unit, a timer unit and an attracted armature auxiliary relay. Resistor and Zener diode combination of the power supply unit provides low voltage stabilised DC supply to the static timer circuit. Non-linear resistors are used in the power supply unit for surge suppression. The timer unit consists of a timer circuit and a thumb wheel switch. The thumb wheel switch mounted on the name plate of the relay provides precise and high resolution time setting. The timer unit operates a reed relay which in turn energises an attracted armature auxiliary relay. This auxiliary relay is provided to achieve higher contact rating and flag indication, if required. Type MDDA is a Definite Time Lag that can be used for applications where an accurate and consistent time-delay operation is required. MDDA can be provided either as a delay on pick up relay or as a delay on drop-off relay. A normally open contact is used for initiating time delay on pick up relay and output element gets energised after the set time delay. In the case of delay on drop off relay, the output element is normally energised and with the normally closed initiating contact opening out, the output elements gets de-energised after the set time delay. Sales Offices Kolkata Easun Reyrolle Ltd. 4, Dr.Sundari Mohan Avenue, 5th Floor Flat No.18, Kolkata - 700 014, India. Tel: +91 33 22848320 Fax: +91 33 22848326 Email: kolkata@easunreyrolle.net Bhopal Easun Reyrolle Ltd. H.No.16, Essarjee Homes Near Gopal Nagar, Kalan Road Piplani, Bhopal - 462 021, India. Telefax: +91 755 2684221 Email: bhopal@easunreyrolle.net Chennai Easun Reyrolle Ltd. 6th Floor, Temple Tower, 672, Anna Salai, Nandanam Chennai - 600 035, India. Tel: +91 44 24346425/24347608 Fax: +91 44 24346435 Email: chennai@easunreyrolle.net Mumbai Secunderabad Easun Reyrolle Ltd. Easun Reyrolle Ltd. 23, Kasturi Building, Jamshedji Tata Road #2, 1st Floor, Paradise Chambers Mumbai - 400 020, India. Opp Hotel Ambassador Tel: +91 22 22022270/22855415 1-7-196 Prender Ghast Road Fax: +91 22 22825703 Secunderabad - 500 003, India. Email: mumbai@easunreyrolle.net Telefax: +91 40 27817847 Email: hyderabad@easunreyrolle.net Delhi Easun Reyrolle Ltd. 29/12, Ground Floor, East Patel Nagar New Delhi - 110 008, India. Tel: +91 11 25747321/25747322 Fax: +91 11 25747320 Email: delhi@easunreyrolle.net Definite Time Lag Relay - MDDA Corporate Office Easun Reyrolle Limited. 98 Sipcot Industrial Complex, Hosur 635 126 India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 www.easunreyrolle.com FACTMDDA/08-07/REV 1 Bangalore Easun Reyrolle Ltd. #17/3 Arakere, Bannerghatta Road, Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: blroffice@easunreyrolle.net