L-807 Wind Cone

advertisement
L-806
Wind Cone
Uses
Provides visual surface wind direction and velocity
information to pilots in flight or on the ground at airports
and heliports.
Features
• The L-806 Wind Cone is a low-mass, frangible-designed
wind cone available in two styles, lighted or unlighted,
with an eight-foot wind sock
• The lighted wind cone assemblies include an L-810
steady-burning red obstruction light
• Sealed hanger bearings allow precision vaning for true
wind direction in all types of weather and wind
conditions
• Mounted on rigid low-mass-supporting assembly
• Easy installation and maintenance
• The lighted wind cone assemblies may be powered by a
6.6A or 20A series circuit using a SAS power adapter or
from a direct 120V AC source
• The nylon fabric sock is treated for water repellency
and resistance to rot and mildew
• The standard color is aviation orange and the colorfastness exceeds Method 5671 of Federal Standard 191.
Other colors such as white or alternate orange/white
checked are available as a special order.
Theory of Operation
The operation of the wind cone is entirely dependent on
the direction and relative velocity of the surface wind.
Movement of the wind through the open throat of the
cage and into the sock causes the tail to inflate. The tail
of the inflated sock indicates true wind direction for
velocities as low as three knots through a 360° circle
about the vertical shaft.
Lighting Assembly
The lighting assembly consists of:
• A 69W, 120V AC, L-810 red incandescent obstruction
light mounted at the highest point of the wind cone
assembly or a 120V AC, 60Hz, L-810 LED red obstruction light and
• A group of four 120W PAR38 halogen floodlights
mounted at 90° intervals on a junction box that
illuminates the exterior of the wind cone (externally
lighted) or two 100W/120V AC reflectorized lamps that
illuminate the interior of the wind cone (internally
lighted)
The internally lighted wind cone can also be supplied
with two 100W/6.6A lamps.
44D1222-X
Type
1 = Size 1, Unlighted
2 = Size 1, Unlighted with L-810 Obstruction Light
4 = Size 1, Externally Lighted without L-810
Obstruction Light
5 = Size 1, Unlighted with L-810 LED Obstruction Light
6 = Size 1, Externally Lighted with L-810 LED
Obstruction Light
Internally Lighted
Order 44D1222-2 (incandescent) or 44D1222-5 (LED),
Size 1, unlighted wind cone with L-810 Obstruction Light.
Include retrofit kit 94A0065 when ordering internally
lighted wind cone. Items supplied in retrofit kit 94A0065
for 8-ft L-806 wind cone:
QTY
1
1
1
Description
Internal Light Kit
Hex Reducer Bushing
(0.75 in x 1 in)
Nipple, 3/4” NPT x 2”
Part No.
44A1925
77A0019
77A0131
Contact the SAS Sales Department for additional wind
sock options. See catalog sheet 2063 for more information on the L-810 LED obstruction light.
Wind Cones
• Bearing covers are provided for additional bearing
protection against dirt and moisture
L-806 Ordering Code
Spare Components
Description
Cage bearings
Cage bearing (weather) shields
Cage assembly
Flood light assembly (External)
Glassware assembly, red LED
Hex nut 5/8-11 SS
Hex sock set screw/8-32 x 3/16
Lamp, 120W/120V AC Par 38 (External)
Lamp, bi-pin,100W/120V (Internal)
Mast assembly
Obstruction light assembly, 69W/120V AC
Obstruction lamp, 69W/120V AC
Ring assembly, middle
Ring assembly, throat
Ring assembly, trail
SBOL LED assembly
Sock, Int'l Orange, nylon
Support rod, basket
Part No.
75B0012
63A0332S
44D0923S
44A5901
44A6334-1
65A0015-37
64A0213-3
48A0078
48A0375
44B1223
44B0936S
48A0009
44C0934-05S
44B0935-02S
44C0934-06S
44A6369-1
77C0061-1
77B0045-01S
1016 Rev. I
Manual No. 96A0052
I-1
Construction
1
1. L-810 Obstruction Light
2. Junction Box
3. External Lighting Assembly
4. 8-ft (2.5 m) Wind Sock
5. Frangible Coupling
6. Pole Support Base
7. Aluminum Mast
8. Bearings
9. Shaft Assembly
3
9
Internally Lighted
Wind Cone Assembly
Rotating Power
Assembly
40.75 in
(103.5
cm)
Wind Cones
112.75 in
(286.4
cm)
Wind Cone
Cage
72 in
(182.9
cm)
Externally Lighted
Wind Cone Assembly
2
48 in
(121.9
cm)
8
4
120 in
(304.8
cm)
72 in
(182.9
cm)
7
Internal Lighted
Assembly
5
Internally Lighted Wind Cone Assembly
6
Externally Lighted Wind Cone Assembly
Internally lighted wind cone has two 100W 120V AC lamps
Packaging
Description Quantity Dimensions
Per Box
8-ft. Wind
Cone
Lighted
1 Pole
8-ft. Wind
Cone
Unlighted
1 Pole
1 Basket
1 Basket
Weight
Externally lighted wind cone has four 120W 120V AC lamps
(H x W x D)
72 x 4 x 4 in
2828.8 x10.2 x 10.2 cm
24 x 24 x 13 in
609.6 x 609.6 x 330.2 cm
15 lb
6.8 kg
45 lb
20.4 kg
72 x 4 x 4 in
2828.8 x 10.2 x 10.2 cm
24 x 24 x 13 in
609.6 x 609.6 x 330.2 cm
15 lb
6.8 kg
40 lb
8.1 kg
The information contained in this document is subject to change without
notice. Siemens reserves the right to make changes and improvements to its
products and assumes no responsibility for making these modifications on
any equipment previously sold.
I-2
1016 Rev. I
Manual No. 96A0052
Siemens Airfield Solutions, Inc.
977 Gahanna Parkway
Columbus, OH 43230
Telephone:
Fax:
614-861-1304
614-864-2069
L-807
Wind Cone
Compliance with Standards
FAA:
ICAO:
L-807 AC 150/5345-27 (Current Edition)
ETL Certified
Annex 14, Vol. 1, para. 5.1.1 (12' wind sock only)
Uses
Provides visual surface wind direction and velocity
information to pilots in flight or on the ground at airports
and heliports.
Features
• The L-807 Wind Cone is a non-frangible designed wind
cone available in two styles, lighted or unlighted, and
in two sizes, eight- or twelve-foot wind socks
• Sealed hanger bearings allow precision vaning for true
wind direction in all types of weather and wind
conditions
• Bearing covers are provided for additional bearing
protection against dirt and moisture
• A swing-out support leg allows the mast to be lowered
to a convenient servicing height for lamp replacement
• The nylon fabric sock is treated for water repellency
and resistance to rot and mildew
• The standard color is aviation orange and the colorfastness exceeds Method 5671 of Federal Standard 191.
Other colors such as white or alternate orange/white
checked are available as a special order.
• The lighted wind cone assemblies may be powered
from a 6.6A or 20A series circuit using a SAS power
adapter or from a direct 120V AC source
Lighting Assembly
• The externally lighted wind cone consists of a group of
four 120W PAR 38 halogen floodlights for an 8-foot
wind cone or five 120W PAR 38 halogen floodlights for
a 12-foot wind cone, which provide a minimum
illumination of 2-foot candles on any point of the
upper surface of a fully extended wind sock
• The internally lighted wind cone consists of two 100W/
120V AC lamps for an 8-foot wind cone or three 100W/
120V AC lamps for a 12-foot wind cone
• A 69W, 120V AC, L-810 red incandescent obstruction
light is supplied with the lighted wind
44D0941-X
Description
1 = Size 1, Unlighted, Style 2, 8-ft without L-810
Obstruction Light
4 = Size 1, Unlighted, Style 2, 8-ft with L-810
Incandescent Obstruction Light
5 = Size 1, Unlighted, Style 2, 8-ft with L-810 LED
Obstruction Light
10 = Size 1, Externally Lighted, 8-ft with L-810
Incandescent Obstruction Light
11 = Size 1, Externally Lighted, 8-ft with L-810 LED
Obstruction Light
13 = Size 2, Unlighted, Style 2, 12-ft without L-810
Obstruction Light
16 = Size 2, Unlighted, Style 2, 12-ft with L-810
Incandescent Obstruction Light
17 = Size 2, Unlighted, Style 2, 12-ft with L-810 LED
Obstruction Light
19 = Size 2, Externally Lighted, 12-ft without L-810
Obstruction Light
22 = Size 2, Externally Lighted, 12-ft with L-810
Incandescent Obstruction Light
23 = Size 2, Externally Lighted, 12-ft with L-810 LED
Obstruction Light
Wind Cones
• An L-810 steady-burning red obstruction light,
mounted on top of the wind cone mast, is included
with the lighted wind cone assemblies
L-807 Ordering Code
Internally Lighted - 12 foot1
Order 44D0941-16 (incandescent) or 44D0941-17 (LED),
Size 2, Unlighted, Style 2, 12-foot with L-810 Obstruction
Light. Include retrofit kit 94A0066 when ordering internally
lighted wind cone. Items supplied in retrofit kit 94A0066 for
12-foot L-807 wind cone:
QTY
1
1
1
Description
Internal Light Kit
Hex Reducer Bushing (0.75 in x 1in)
Nipple, 3/4” NPT x 2”
Part No.
44A1926
77A0019
77A0131
Notes
Contact the SAS Sales Department for additional wind sock
options
1
Not ETL Certified
• An optional 9W (49VA),120V AC, 60Hz L-810 LED red
obstruction light is available. See catalog sheet 2063
for more details.
1005 Rev. I
Manual No. 96A0003
I-3
Theory of Operation
The operation of the wind cone is entirely dependent on
the direction and relative velocity of the surface wind.
Movement of the wind through the open throat of the
cage and into the sock causes the tail to inflate. The tail
of the inflated sock indicates true wind direction for
velocities as low as three knots through a 360° circle
about the vertical shaft.
Packaging
Description Quantity
Per Box
Dimensions
(H x W x D)
Weight
8-ft. Wind
Cone
Lighted
16.6 x 10 x 10 in
502.9 x 25.4 x 25.4 cm
20 x 20 x 15 in
50.8 x 50.8 x 38.1 cm
150 lb
68 kg
47 lb
21.3 kg
16.6 x 10 x 10 in
502.9 x 25.4 x 25.4 cm
20 x 20 x 15 in
50.8 x 50.8 x 38.1 cm
135 lb
61.2 kg
42 lb
19.1 kg
16.6 x 10 x 10 in
502.9 x 25.4 x 25.4 cm
45 x 42 x 6 in
114.3 x 106.7 x 15.2 cm
20 x 20 x 15 in
50.8 x 50.8 x 38.1 cm
150 lb
68 kg
47 lb
21.3 kg
45 lb
20.4 kg
16.6 x 10 x 10 in
502.9 x 25.4 x 25.4 cm
45 x 42 x 6 in
114.3 x 106.7 x 15.2 cm
20 x 20 x 15 in
50.8 x 50.8 x 38.1 cm
135 lb
61.2 kg
42 lb
19.1kg
45 lb
20.4 kg
8-ft. Wind
Cone
Unlighted
12-ft. Wind
Cone
Lighted
1 Pole
1 Basket
1 Pole
1 Basket
1 Pole
1 Basket
Wind Cones
Hardware
12-ft. Wind
Cone
Unlighted
1 Pole
1 Basket
Hardware
Spare Components
Description
Cage assembly, 8 ft
Cage assembly, 12 ft
Cage bearings
Cage bearing (weather) shields
External light assembly, 8 ft
External light assembly, 12 ft
Glassware assembly, red LED
Lamp, 120W, 120V AC Par 38 (External)
Lamp, bi-pin 100W, 120V AC (Internal)1
Obstruction light assembly, 69W, 120V
Obstruction lamp, 69W, 120V
Pole assembly, 8 ft
Pole assembly, 12 ft
Ring assembly, middle, 8 ft
Ring assembly, middle, 12 ft
Ring assembly, tail, 8 ft
Ring assembly, tail, 12 ft
Ring assembly, throat, 8 ft
Ring assembly, throat, 12 ft
Rope cleat
SBOL LED assembly
Shoulder screw, 3/8-16 x 1/2-inch
Sock, Int'l Orange, nylon, 8 ft
Sock, Int'l Orange, nylon, 12 ft
Support rod, 8 ft, basket
Support rod, 12 ft, basket
Part No.
44D0923
44D0919S
75B0012
63A0332S
44A5902
44A5853
44A6334-1
48A0078
48A0375
44B0936S
48A0009
44D0940S
44D1845
44C0934-05S
44C0934-02S
44C0934-06S
44C0934-03S
44B0935-02S
44B0935-01S
62B0319S
44A6369-1
64A0072
77C0061-1
77C0062-1
77B0045-01S
77B0045-02S
Externally Lighted Wind Cone
1
8.0 in
2
48 in (Size 1)
50 in (Size 2)
Internally Lighted Wind Cone*
8-ft (Size 1)
12-ft (Size 2)
Fully Extended
3
26 in (Size 1)
43 in (Size 2)
40.25 in (Size 1)
58.25 in (Size 2)
5
6
4
7
192 in
8
9
10
192 in
11
12
Construction
* Internally lighted wind cone is ETL Certified for 12-foot
only.
1.
2.
3.
4.
5.
6.
L-810 Obstruction Light
External Lighting Assembly
Bearings
Basket Assembly
Wind Sock
Mast Lowering Rope
7. Support Arm Assembly
8. Pole
9. Lowering Placard
10. Optional Tether
11. Pivot Point
12. Pole Support Base
The information contained in this document is subject to change without
notice. Siemens reserves the right to make changes and improvements to its
products and assumes no responsibility for making these modifications on any
equipment previously sold.
I-4
1005 Rev. I
Manual No. 96A0003
Siemens Airfield Solutions, Inc.
977 Gahanna Parkway
Columbus, OH 43230
Telephone:
Fax:
614-861-1304
614-864-2069
L-810
Obstruction Light
Compliance with Standards
FAA:
ICAO:
L-810 AC 150/5345-43 (Current Edition)
ETL Certified
Annex 14, Vol. 1, para. 6.3.11 for use as
low-intensity obstacle light
Ordering Code
L-810 Single/Dual Fixture Without Lamp-Out Relay
Uses
Steady-burning red incandescent light fixture marking all
fixed obstructions to eliminate air navigational hazards.
Features
• Optional lamp-out relay switches power to reserve
lamp if the normally operating lamp fails. Available only
on dual 120V AC fixtures.
• Units with lamp-out relay have an alarm terminal that
can activate an alarm (user-supplied) in case of lamp
failure
• Mounting Hub–Three optional mounting ports are
available for the dual L-810 with the lamp-out relay
option:
- standard bottom port (1- to 11.5-inch normal pipe
thread)
- side port (1- to 11.5-inch normal pipe thread)
- side port (0.75- to 14-inch normal pipe thread)
Units without lamp-out relay option:
- standard bottom port (1- to 11.5-inch normal pipe
thread)
45W/6.6A
69W/120V AC
116W/120V AC
116W/130V AC
• Lamp Life: 120V AC lamps rated at 8,000 hours, 6.6A
lamps rated at 1,000 hours
• Gasket seal between lens cap and fixture base prevents
moisture penetration
44C100X-X
Fixture
5 = Single Light Fixture
7 = Dual Light Fixture
Lamp Wattage
1 = 120V AC Fixture With 69W Lamp*
2 = 6.6A Fixture With 45W Lamp
3 = 120V AC Fixture Only (No Lamps)
4 = 6.6 A Fixture Only (No Lamps)
6 = 120V AC Fixture With 116W Lamp
7 = 130V AC Fixture With 116W Lamp
L-810 Dual Light Fixture With Lamp-Out Relay
44C1532-XX1X
Lamp Wattage
1 = 120V AC Fixture With 69W Lamp
3 = 120V AC Fixture With 116W Lamp
Include Lamp
0 = Fixture Without Lamps
1 = Fixture With Lamps
Port Size/Location
1 = 1-11.5-in NPT Bottom Port (Standard)
2 = 1-11.5-in NPT Side Port (Special Order)
3 = 0.75-14-in NPT Side Port (Special Order)
Note
* ETL Certified
Obstruction Lights
• All parts are corrosion-resistant
• Optional Lamps: -
L-810 Dual Light Fixture
• Two spring latches allow fast removal of the red lens
cap from the base of the fixture for replacing lamps
and lenses, providing easy maintenance
• A safety cable attached to the lens cap permits handsfree, rapid lamp and lens replacement
• Both single or dual units are available for use with
either 120V AC parallel or 6.6A series lighting circuits
Environmental Conditions
Temperature: -67°F to +131°F (-55°C to +55°C)
Humidity: 0 to 100%
Wind speeds: Up to 150 mph (240 kph)
1013 Rev. H
Manual No. 96A0006
I-5
Lamp-Out Relay Operation
Spare Components
120V AC input power to the dual L-810 fixture energizes a
relay and the normally operating lamp #1. If lamp #1 fails,
the relay is de-energized causing the 120V AC to be
switched to the backup lamp #2. At the same time, 120V
AC power is also switched to the alarm terminal, which
can be used to activate a user-supplied alarm.
Description
Gasket
Lamp, 45W/6.6A
Lamp, 69W/120V
Lamp, 116W/120V AC
Lamp, 116W/130V AC (Dual Only)
Lamp-out relay
Lens clamp (clamp lever)
Lens, collar (2 required per lens)
Lens, red
Socket, 45W/6.6A
Socket, 69W, 116W/120-130V AC
Packaging
Single
Actual
in
cm
5.63 dia. x 8.09 H
14.30 dia. x 20.55 H
In cardboard box:
in
cm
6 H x 6 W x 8.5 D
15.24 H x 15.24 W x 21.59 D
Net weight:
4 lb (1.81 kg)
Part No.
63B0015-1
48A0007
48A0009
48A0010
48A0169
53A0232
61A0130
62B0457S
63A0149
49A0002
49A0014
Construction
Obstruction Lights
Dual
Actual
in
cm
5.63 dia. x 8.06 H x 12.25 W
14.30 dia. x 20.47 H x 31.12 W
In cardboard box:
in
cm
12 H x 9 W x 9.5 D
30.48 H x 22.86 W x 24.13 D
Net weight:
8 lb (3.63 kg)
The information contained in this document is subject to change without
notice. Siemens reserves the right to make changes and improvements to its
products and assumes no responsibility for making these modifications on
any equipment previously sold.
I-6
1013 Rev. H
Manual No. 96A0006
Siemens Airfield Solutions, Inc.
977 Gahanna Parkway
Columbus, OH 43230
Telephone:
Fax:
614-861-1304
614-864-2069
Download