L-806 Wind Cone Uses Provides visual surface wind direction and velocity information to pilots in flight or on the ground at airports and heliports. Features • The L-806 Wind Cone is a low-mass, frangible-designed wind cone available in two styles, lighted or unlighted, with an eight-foot wind sock • The lighted wind cone assemblies include an L-810 steady-burning red obstruction light • Sealed hanger bearings allow precision vaning for true wind direction in all types of weather and wind conditions • Mounted on rigid low-mass-supporting assembly • Easy installation and maintenance • The lighted wind cone assemblies may be powered by a 6.6A or 20A series circuit using a SAS power adapter or from a direct 120V AC source • The nylon fabric sock is treated for water repellency and resistance to rot and mildew • The standard color is aviation orange and the colorfastness exceeds Method 5671 of Federal Standard 191. Other colors such as white or alternate orange/white checked are available as a special order. Theory of Operation The operation of the wind cone is entirely dependent on the direction and relative velocity of the surface wind. Movement of the wind through the open throat of the cage and into the sock causes the tail to inflate. The tail of the inflated sock indicates true wind direction for velocities as low as three knots through a 360° circle about the vertical shaft. Lighting Assembly The lighting assembly consists of: • A 69W, 120V AC, L-810 red incandescent obstruction light mounted at the highest point of the wind cone assembly or a 120V AC, 60Hz, L-810 LED red obstruction light and • A group of four 120W PAR38 halogen floodlights mounted at 90° intervals on a junction box that illuminates the exterior of the wind cone (externally lighted) or two 100W/120V AC reflectorized lamps that illuminate the interior of the wind cone (internally lighted) The internally lighted wind cone can also be supplied with two 100W/6.6A lamps. 44D1222-X Type 1 = Size 1, Unlighted 2 = Size 1, Unlighted with L-810 Obstruction Light 4 = Size 1, Externally Lighted without L-810 Obstruction Light 5 = Size 1, Unlighted with L-810 LED Obstruction Light 6 = Size 1, Externally Lighted with L-810 LED Obstruction Light Internally Lighted Order 44D1222-2 (incandescent) or 44D1222-5 (LED), Size 1, unlighted wind cone with L-810 Obstruction Light. Include retrofit kit 94A0065 when ordering internally lighted wind cone. Items supplied in retrofit kit 94A0065 for 8-ft L-806 wind cone: QTY 1 1 1 Description Internal Light Kit Hex Reducer Bushing (0.75 in x 1 in) Nipple, 3/4” NPT x 2” Part No. 44A1925 77A0019 77A0131 Contact the SAS Sales Department for additional wind sock options. See catalog sheet 2063 for more information on the L-810 LED obstruction light. Wind Cones • Bearing covers are provided for additional bearing protection against dirt and moisture L-806 Ordering Code Spare Components Description Cage bearings Cage bearing (weather) shields Cage assembly Flood light assembly (External) Glassware assembly, red LED Hex nut 5/8-11 SS Hex sock set screw/8-32 x 3/16 Lamp, 120W/120V AC Par 38 (External) Lamp, bi-pin,100W/120V (Internal) Mast assembly Obstruction light assembly, 69W/120V AC Obstruction lamp, 69W/120V AC Ring assembly, middle Ring assembly, throat Ring assembly, trail SBOL LED assembly Sock, Int'l Orange, nylon Support rod, basket Part No. 75B0012 63A0332S 44D0923S 44A5901 44A6334-1 65A0015-37 64A0213-3 48A0078 48A0375 44B1223 44B0936S 48A0009 44C0934-05S 44B0935-02S 44C0934-06S 44A6369-1 77C0061-1 77B0045-01S 1016 Rev. I Manual No. 96A0052 I-1 Construction 1 1. L-810 Obstruction Light 2. Junction Box 3. External Lighting Assembly 4. 8-ft (2.5 m) Wind Sock 5. Frangible Coupling 6. Pole Support Base 7. Aluminum Mast 8. Bearings 9. Shaft Assembly 3 9 Internally Lighted Wind Cone Assembly Rotating Power Assembly 40.75 in (103.5 cm) Wind Cones 112.75 in (286.4 cm) Wind Cone Cage 72 in (182.9 cm) Externally Lighted Wind Cone Assembly 2 48 in (121.9 cm) 8 4 120 in (304.8 cm) 72 in (182.9 cm) 7 Internal Lighted Assembly 5 Internally Lighted Wind Cone Assembly 6 Externally Lighted Wind Cone Assembly Internally lighted wind cone has two 100W 120V AC lamps Packaging Description Quantity Dimensions Per Box 8-ft. Wind Cone Lighted 1 Pole 8-ft. Wind Cone Unlighted 1 Pole 1 Basket 1 Basket Weight Externally lighted wind cone has four 120W 120V AC lamps (H x W x D) 72 x 4 x 4 in 2828.8 x10.2 x 10.2 cm 24 x 24 x 13 in 609.6 x 609.6 x 330.2 cm 15 lb 6.8 kg 45 lb 20.4 kg 72 x 4 x 4 in 2828.8 x 10.2 x 10.2 cm 24 x 24 x 13 in 609.6 x 609.6 x 330.2 cm 15 lb 6.8 kg 40 lb 8.1 kg The information contained in this document is subject to change without notice. Siemens reserves the right to make changes and improvements to its products and assumes no responsibility for making these modifications on any equipment previously sold. I-2 1016 Rev. I Manual No. 96A0052 Siemens Airfield Solutions, Inc. 977 Gahanna Parkway Columbus, OH 43230 Telephone: Fax: 614-861-1304 614-864-2069 L-807 Wind Cone Compliance with Standards FAA: ICAO: L-807 AC 150/5345-27 (Current Edition) ETL Certified Annex 14, Vol. 1, para. 5.1.1 (12' wind sock only) Uses Provides visual surface wind direction and velocity information to pilots in flight or on the ground at airports and heliports. Features • The L-807 Wind Cone is a non-frangible designed wind cone available in two styles, lighted or unlighted, and in two sizes, eight- or twelve-foot wind socks • Sealed hanger bearings allow precision vaning for true wind direction in all types of weather and wind conditions • Bearing covers are provided for additional bearing protection against dirt and moisture • A swing-out support leg allows the mast to be lowered to a convenient servicing height for lamp replacement • The nylon fabric sock is treated for water repellency and resistance to rot and mildew • The standard color is aviation orange and the colorfastness exceeds Method 5671 of Federal Standard 191. Other colors such as white or alternate orange/white checked are available as a special order. • The lighted wind cone assemblies may be powered from a 6.6A or 20A series circuit using a SAS power adapter or from a direct 120V AC source Lighting Assembly • The externally lighted wind cone consists of a group of four 120W PAR 38 halogen floodlights for an 8-foot wind cone or five 120W PAR 38 halogen floodlights for a 12-foot wind cone, which provide a minimum illumination of 2-foot candles on any point of the upper surface of a fully extended wind sock • The internally lighted wind cone consists of two 100W/ 120V AC lamps for an 8-foot wind cone or three 100W/ 120V AC lamps for a 12-foot wind cone • A 69W, 120V AC, L-810 red incandescent obstruction light is supplied with the lighted wind 44D0941-X Description 1 = Size 1, Unlighted, Style 2, 8-ft without L-810 Obstruction Light 4 = Size 1, Unlighted, Style 2, 8-ft with L-810 Incandescent Obstruction Light 5 = Size 1, Unlighted, Style 2, 8-ft with L-810 LED Obstruction Light 10 = Size 1, Externally Lighted, 8-ft with L-810 Incandescent Obstruction Light 11 = Size 1, Externally Lighted, 8-ft with L-810 LED Obstruction Light 13 = Size 2, Unlighted, Style 2, 12-ft without L-810 Obstruction Light 16 = Size 2, Unlighted, Style 2, 12-ft with L-810 Incandescent Obstruction Light 17 = Size 2, Unlighted, Style 2, 12-ft with L-810 LED Obstruction Light 19 = Size 2, Externally Lighted, 12-ft without L-810 Obstruction Light 22 = Size 2, Externally Lighted, 12-ft with L-810 Incandescent Obstruction Light 23 = Size 2, Externally Lighted, 12-ft with L-810 LED Obstruction Light Wind Cones • An L-810 steady-burning red obstruction light, mounted on top of the wind cone mast, is included with the lighted wind cone assemblies L-807 Ordering Code Internally Lighted - 12 foot1 Order 44D0941-16 (incandescent) or 44D0941-17 (LED), Size 2, Unlighted, Style 2, 12-foot with L-810 Obstruction Light. Include retrofit kit 94A0066 when ordering internally lighted wind cone. Items supplied in retrofit kit 94A0066 for 12-foot L-807 wind cone: QTY 1 1 1 Description Internal Light Kit Hex Reducer Bushing (0.75 in x 1in) Nipple, 3/4” NPT x 2” Part No. 44A1926 77A0019 77A0131 Notes Contact the SAS Sales Department for additional wind sock options 1 Not ETL Certified • An optional 9W (49VA),120V AC, 60Hz L-810 LED red obstruction light is available. See catalog sheet 2063 for more details. 1005 Rev. I Manual No. 96A0003 I-3 Theory of Operation The operation of the wind cone is entirely dependent on the direction and relative velocity of the surface wind. Movement of the wind through the open throat of the cage and into the sock causes the tail to inflate. The tail of the inflated sock indicates true wind direction for velocities as low as three knots through a 360° circle about the vertical shaft. Packaging Description Quantity Per Box Dimensions (H x W x D) Weight 8-ft. Wind Cone Lighted 16.6 x 10 x 10 in 502.9 x 25.4 x 25.4 cm 20 x 20 x 15 in 50.8 x 50.8 x 38.1 cm 150 lb 68 kg 47 lb 21.3 kg 16.6 x 10 x 10 in 502.9 x 25.4 x 25.4 cm 20 x 20 x 15 in 50.8 x 50.8 x 38.1 cm 135 lb 61.2 kg 42 lb 19.1 kg 16.6 x 10 x 10 in 502.9 x 25.4 x 25.4 cm 45 x 42 x 6 in 114.3 x 106.7 x 15.2 cm 20 x 20 x 15 in 50.8 x 50.8 x 38.1 cm 150 lb 68 kg 47 lb 21.3 kg 45 lb 20.4 kg 16.6 x 10 x 10 in 502.9 x 25.4 x 25.4 cm 45 x 42 x 6 in 114.3 x 106.7 x 15.2 cm 20 x 20 x 15 in 50.8 x 50.8 x 38.1 cm 135 lb 61.2 kg 42 lb 19.1kg 45 lb 20.4 kg 8-ft. Wind Cone Unlighted 12-ft. Wind Cone Lighted 1 Pole 1 Basket 1 Pole 1 Basket 1 Pole 1 Basket Wind Cones Hardware 12-ft. Wind Cone Unlighted 1 Pole 1 Basket Hardware Spare Components Description Cage assembly, 8 ft Cage assembly, 12 ft Cage bearings Cage bearing (weather) shields External light assembly, 8 ft External light assembly, 12 ft Glassware assembly, red LED Lamp, 120W, 120V AC Par 38 (External) Lamp, bi-pin 100W, 120V AC (Internal)1 Obstruction light assembly, 69W, 120V Obstruction lamp, 69W, 120V Pole assembly, 8 ft Pole assembly, 12 ft Ring assembly, middle, 8 ft Ring assembly, middle, 12 ft Ring assembly, tail, 8 ft Ring assembly, tail, 12 ft Ring assembly, throat, 8 ft Ring assembly, throat, 12 ft Rope cleat SBOL LED assembly Shoulder screw, 3/8-16 x 1/2-inch Sock, Int'l Orange, nylon, 8 ft Sock, Int'l Orange, nylon, 12 ft Support rod, 8 ft, basket Support rod, 12 ft, basket Part No. 44D0923 44D0919S 75B0012 63A0332S 44A5902 44A5853 44A6334-1 48A0078 48A0375 44B0936S 48A0009 44D0940S 44D1845 44C0934-05S 44C0934-02S 44C0934-06S 44C0934-03S 44B0935-02S 44B0935-01S 62B0319S 44A6369-1 64A0072 77C0061-1 77C0062-1 77B0045-01S 77B0045-02S Externally Lighted Wind Cone 1 8.0 in 2 48 in (Size 1) 50 in (Size 2) Internally Lighted Wind Cone* 8-ft (Size 1) 12-ft (Size 2) Fully Extended 3 26 in (Size 1) 43 in (Size 2) 40.25 in (Size 1) 58.25 in (Size 2) 5 6 4 7 192 in 8 9 10 192 in 11 12 Construction * Internally lighted wind cone is ETL Certified for 12-foot only. 1. 2. 3. 4. 5. 6. L-810 Obstruction Light External Lighting Assembly Bearings Basket Assembly Wind Sock Mast Lowering Rope 7. Support Arm Assembly 8. Pole 9. Lowering Placard 10. Optional Tether 11. Pivot Point 12. Pole Support Base The information contained in this document is subject to change without notice. Siemens reserves the right to make changes and improvements to its products and assumes no responsibility for making these modifications on any equipment previously sold. I-4 1005 Rev. I Manual No. 96A0003 Siemens Airfield Solutions, Inc. 977 Gahanna Parkway Columbus, OH 43230 Telephone: Fax: 614-861-1304 614-864-2069 L-810 Obstruction Light Compliance with Standards FAA: ICAO: L-810 AC 150/5345-43 (Current Edition) ETL Certified Annex 14, Vol. 1, para. 6.3.11 for use as low-intensity obstacle light Ordering Code L-810 Single/Dual Fixture Without Lamp-Out Relay Uses Steady-burning red incandescent light fixture marking all fixed obstructions to eliminate air navigational hazards. Features • Optional lamp-out relay switches power to reserve lamp if the normally operating lamp fails. Available only on dual 120V AC fixtures. • Units with lamp-out relay have an alarm terminal that can activate an alarm (user-supplied) in case of lamp failure • Mounting Hub–Three optional mounting ports are available for the dual L-810 with the lamp-out relay option: - standard bottom port (1- to 11.5-inch normal pipe thread) - side port (1- to 11.5-inch normal pipe thread) - side port (0.75- to 14-inch normal pipe thread) Units without lamp-out relay option: - standard bottom port (1- to 11.5-inch normal pipe thread) 45W/6.6A 69W/120V AC 116W/120V AC 116W/130V AC • Lamp Life: 120V AC lamps rated at 8,000 hours, 6.6A lamps rated at 1,000 hours • Gasket seal between lens cap and fixture base prevents moisture penetration 44C100X-X Fixture 5 = Single Light Fixture 7 = Dual Light Fixture Lamp Wattage 1 = 120V AC Fixture With 69W Lamp* 2 = 6.6A Fixture With 45W Lamp 3 = 120V AC Fixture Only (No Lamps) 4 = 6.6 A Fixture Only (No Lamps) 6 = 120V AC Fixture With 116W Lamp 7 = 130V AC Fixture With 116W Lamp L-810 Dual Light Fixture With Lamp-Out Relay 44C1532-XX1X Lamp Wattage 1 = 120V AC Fixture With 69W Lamp 3 = 120V AC Fixture With 116W Lamp Include Lamp 0 = Fixture Without Lamps 1 = Fixture With Lamps Port Size/Location 1 = 1-11.5-in NPT Bottom Port (Standard) 2 = 1-11.5-in NPT Side Port (Special Order) 3 = 0.75-14-in NPT Side Port (Special Order) Note * ETL Certified Obstruction Lights • All parts are corrosion-resistant • Optional Lamps: - L-810 Dual Light Fixture • Two spring latches allow fast removal of the red lens cap from the base of the fixture for replacing lamps and lenses, providing easy maintenance • A safety cable attached to the lens cap permits handsfree, rapid lamp and lens replacement • Both single or dual units are available for use with either 120V AC parallel or 6.6A series lighting circuits Environmental Conditions Temperature: -67°F to +131°F (-55°C to +55°C) Humidity: 0 to 100% Wind speeds: Up to 150 mph (240 kph) 1013 Rev. H Manual No. 96A0006 I-5 Lamp-Out Relay Operation Spare Components 120V AC input power to the dual L-810 fixture energizes a relay and the normally operating lamp #1. If lamp #1 fails, the relay is de-energized causing the 120V AC to be switched to the backup lamp #2. At the same time, 120V AC power is also switched to the alarm terminal, which can be used to activate a user-supplied alarm. Description Gasket Lamp, 45W/6.6A Lamp, 69W/120V Lamp, 116W/120V AC Lamp, 116W/130V AC (Dual Only) Lamp-out relay Lens clamp (clamp lever) Lens, collar (2 required per lens) Lens, red Socket, 45W/6.6A Socket, 69W, 116W/120-130V AC Packaging Single Actual in cm 5.63 dia. x 8.09 H 14.30 dia. x 20.55 H In cardboard box: in cm 6 H x 6 W x 8.5 D 15.24 H x 15.24 W x 21.59 D Net weight: 4 lb (1.81 kg) Part No. 63B0015-1 48A0007 48A0009 48A0010 48A0169 53A0232 61A0130 62B0457S 63A0149 49A0002 49A0014 Construction Obstruction Lights Dual Actual in cm 5.63 dia. x 8.06 H x 12.25 W 14.30 dia. x 20.47 H x 31.12 W In cardboard box: in cm 12 H x 9 W x 9.5 D 30.48 H x 22.86 W x 24.13 D Net weight: 8 lb (3.63 kg) The information contained in this document is subject to change without notice. Siemens reserves the right to make changes and improvements to its products and assumes no responsibility for making these modifications on any equipment previously sold. I-6 1013 Rev. H Manual No. 96A0006 Siemens Airfield Solutions, Inc. 977 Gahanna Parkway Columbus, OH 43230 Telephone: Fax: 614-861-1304 614-864-2069