Electromechanical Preset Counters with Manual and/or Electric Reset and 1 Preset, subtracting FS218, FS219 Features – Preset counter with 1 preset – Subtracting – With manual or electric reset Order designation Order no. A3 B5 B8 B9 FS218.550B FS219.550B Electrical data Counting Voltage DC 24 VDC ± 10 % Rating Min. pulse duration Min. pulse interval Load factor at 25 °C 4W 50 ms 50 ms 100 % Electric reset Voltage DC 24 VDC ± 10 % Rating Min. pulse duration Min. pulse interval Load factor at 25 °C 30 W 300 ms 9 x pulse length 10 % max. 1 min Contact load E-connection Residual ripple/ Frequency End contact 126 AC 24 VAC ± 10 % 110 VAC ± 10 % 230 VAC +6/-10 % 5 VA 50 ms 50 ms 100 % AC 24 VAC ± 10 % 110 VAC ± 10 % 230 VAC +6/-10 % 42 VA 300 ms 9 x pulse length 10 % max. 1 min DC: max. 30 W, 230 V, 1 A AC: max. 100 VA, 230 V, 2 A Plug-on terminal strip with 10 pins for max. 2.5 mm2 DC: ≤ 48 % AC: 50...60 Hz FS219 in AC and with precontact provides only one contact each as NC or NO for the precontact resp. end contact (standard: NC) due to the limited number of terminals available. Please indicate NC (normally closed) or NO (normally open) when ordering. B B Voltage 24 VDC 24 VAC 110 VAC 230 VAC With button reset, 5-digit display With button and electric reset, 5-digit display Mechanical data Mode Display Digit size Counting mode Reset Mounting Front dimensions Housing material Weight Service life Output contact The counter subtracts from the preset value and outputs a switching contact upon reaching 0. The contact remains latched in spite of further arriving counting pulses. 5-digit, 99999 Approx. 8 mm high, white on black 1 pulse = 1 digit subtracted Manual by key or electrical Front panel by means of 4 screws 144 x 72 mm Hostaform (POM), black FS218 approx. 650 g FS219 approx. 850 g Counting: approx. 108 pulses Electric reset: 106 pulses The integrated switch is a conventional microswitch with a one-pin changeover contact. Mechanical service life: approx. 1 million switch operations, electrical service life depending on load. In case of inductive load, a spark quenching should be applied. www.ivo.de FS218, FS219 Pin assignment Protection Operational requirements Protection standard Interference immunity Emitted interference General rating Overvoltage protection -5...+50 °C -20...+70 °C Max. relative humidity 80 %, at 25 °C, non-condensing Front IP 41 per DIN 40050 To contamination degree 2 EN 61010 Category II EN 50082-2 EN 50081-1 EN 61010 II FS218 for DC FS218 for AC + – 1 2 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 -(+) Ambient temperature Storage temperature Relative humidity +(-) Ambient conditions Voltage Pulse FS219 for DC Voltage End contact FS219 for AC + * – 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 +(-) -(+) Voltage Reset Pulse Voltage Reset Accessories Order no. Z 100.04A Flexible transparent protective cover End contact * Also available as normally open. Please indicate when placing your order. Dimensions Countersinking 21 Af4 DIN74 112 14.6 72 62 60 6 16 5 5 134 144 129 3.5 134 0.5 62 61 +0.5 M4 10.5 113 +0.5 www.ivo.de Cutout for screw mounting 127 3