2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-1020-7 Name: 3P-1020 3P 100: DATE: JAN 19 2006 Time: 6:08:45 PM Operator: RB Arktite® WSRD SMS901 Stainless Steel Interlocked Receptacles COLOR: CMYK TCP: 15001 30, 60 and 100 Amp Enclosure Type 3,4,4X,12 IP66 UL and cUL Listed Typedriver Name: TS name csm no.: 100 Watertight Corrosion-Resistant Fused and Non-Fused WSRD SMS901 SERIES STAINLESS STEEL ARKTITE® INTERLOCKED RECEPTACLES Cooper Crouse-Hinds Arktite Stainless Steel Interlocks prevent engagement and disengagement of the plug under load, providing safe portable connections and extended product life. Available in 30-100 Amp in both fused and nonfused versions, the Stainless Steel Interlock is rated Enclosure Type 4X watertight and features an optional viewing window. Arktite stainless steel interlocked receptacles: ឣ supply power to portable or fixed electrical equipment such as welders, compressors, conveyors, portable tools, lighting systems and similar equipment. ឣ are used in damp or corrosive locations. ឣ are ideal for use in wet locations & hosedown areas. ADDITIONAL FEATURES AND BENEFITS ɀ Heavy duty Arktite receptacle is compatible with existing Cooper Crouse-Hinds Arktite plugs of same rating and configuration. ɀ Self-wiping, naval brass contacts in receptacle assure reliable performance and long dependable life ɀ Stainless steel interior hardware. ɀ Ground bar supplied as standard and connected to 4th wire in receptacle. ɀ UL and cUL Listed ORDERING INFORMATION (3 Pole, 4 Wire - 600 VAC) Catalog Amps Number 1020 STIBOINFO((CRH:66008com:3P:1020)) CH0 0 4 F - 5 US: 1-866-764-5454 Description Cooper Crouse-Hinds Weight Mating Arktite Plug lbs. Catalog Numbers 30 30 30 WSRDW3352SMS901 WSRD33542SMS901 WSRDW33542SMS901 Fused w/Window Non-Fused Non-Fused w/Window 24 22 22 APJ3485 & NPJ3485 APJ3485 & NPJ3485 APJ3485 & NPJ3485 60 60 60 WSRDW6352SMS901 WSRD63542SMS901 WSRDW63542SMS901 Fused w/Window Non-Fused Non-Fused w/Window 30 29 29 APJ6485 & NPJ6485 APJ6485 & NPJ6485 APJ6485 & NPJ6485 100 100 100 WSRDW10352SMS901 Fused w/Window WSRD103542SMS901 Non-Fused WSRDW103542SMS901 Non-Fused w/Window 36 35 35 APJ10487 & NPJ10487 APJ10487 & NPJ10487 APJ10487 & NPJ10487 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-1018-1 Name: 3P-1018 100: DATE: JAN 19 2006 Typedriver Name: TS name csm no.: 100 30,60,100A NEMA 3,3R,4,4X,12 Raintight Watertight Corrosion-Resistant WSR WSRD WSRDW Sheet Metal NEMA 3R,12 Sheet Metal Viewing Window NEMA 3R,12 ɀ The WSR and WSRD disconnect switches are used as a service outlet for portable or fixed electrical equipment – generators, compressors, welders, etc. ɀ They are designed for use in nonhazardous areas where dust, moisture and corrosion may be a problem. ɀ Designed for flush or surface mounting. ɀ A fusible type switch, when used, also provides short circuit protection. Features: WSR and WSRD: ɀ Switches are NEMA type HD heavy duty 3-pole, with visible blades; a quick makeand-break mechanism with reinforced, positive pressure type blade and jaw construction. Fusible types have fuse clips with steel reinforcing springs of positive pressure type. Pressure connectors are used for wire connectors. ɀ For maximum safety, the spring door receptacle at the bottom of the unit is mechanically interlocked with the switch operating mechanism. The switch cannot be closed until the plug is fully inserted and the plug cannot be withdrawn or inserted unless the switch is open. With the switch open, accidental plug withdrawal is prevented by the interlock mechanism. Withdrawal can only be accomplished by activation of the interlock release lever located on the receptacle. ɀ Enclosures are compact and rectangular in shape with a gasketed, hinged door. ɀ Enclosure, handle and other exterior parts are corrosion resistant. STIBOINFO((CRH:66008com:3P:1018)) TCP: 15001 Aluminum NEMA 3R,12 Application: CH0 0 3 P - 2 COLOR: CMYK WSR, WSRD, WSRDW Interlocked Arktite® Receptacles with Enclosed Disconnect Switches 3P 1018 Time: 6:08:42 PM Operator: RB ɀ The switch enclosure covers are interlocked with the body and operating mechanism and cannot be opened when the plug is engaged and the switch is closed (‘‘ON’’). When the switch is open, the switch cannot be put in a closed (‘‘ON’’) position with the door open. WSR: ɀ Mounting lugs may be rotated 90° or moved to the vertical centerline portion for pole mounting. ɀ Side hinged covers are retained in a closed position by compression spring draw-pull catches, which permit the opening or closing of the cover without tools. ɀ The switch operating handle may be padlocked in the ‘‘ON’’ or ‘‘OFF’’ position, thereby preventing unauthorized operation of the switch and/or opening of the enclosure. Up to three padlocks may be used. In addition, a unique hinge arrangement has been devised to allow the door of the unit to be padlocked. This feature allows operation while preventing unqualified or unauthorized entry. Standard Materials: WSR and WSRD: ɀ Receptacle housings and plug exteriors – copper-free aluminum ɀ Insulation (plug and receptacle) – fiberglass-reinforced polyester ɀ Pressure contacts – brass ɀ Crimp/solder contacts – leaded red brass WSR: ɀ Enclosure – copper-free aluminum ɀ Operating handle – copper-free aluminum ɀ Other exterior parts – stainless steel WSRD: ɀ Enclosure – sheet steel ɀ Operating handle – sheet steel ɀ Other exterior parts – stainless steel US: 1-866-764-5454 CAN: 1-800-265-0502 Standard Finishes: ɀ Copper-free aluminum – WSR enclosure, plug exteriors – natural ɀ Leaded red brass – electro-tin-plate ɀ Brass – natural ɀ Sheet steel – baked grey enamel ɀ Fiberglass-reinforced polyester – natural (red) Electrical Rating Ranges: ɀ 3 and 4 pole; fusible or non-fusible; 240 vac, 250 vdc; 600 vac ɀ 30, 60, 100 amperes ɀ 71⁄2 to 75 HP Certifications and Compliances: WSR: ɀ NEMA 3R, 4, 12 (enclosure) ɀ UL Standard 98 WSRD: ɀ NEMA 3R, 12 ɀ UL Standard 98 Options: ɀ Interiors rotated 221⁄2° to the right (viewed from face) – add suffix S4 to Cat. No. ɀ Auxiliary switch, 600 vac-dc heavy duty push button station rating, can be supplied, and its contacts will close after safety switch contacts open and close before safety switch opens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S483 ɍɍ Pressure connectors are supplied as standard. To specify crimp/solder type terminations, add the suffix ‘‘T’’ to the catalog number. For example: APJ3375-T (Plug) Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-1022-3 Name: 3P-1022 3P DATE: JAN 19 2006 Time: 6:08:49 PM Operator: JB COLOR: CMYK Arktite® WSRD SM S901 Stainless Steel Interlocked Receptacles TCP: 15001 30, 60 and 100 Amp Enclosure Type 3,4,4X,12 IP66 UL and cUL Listed Typedriver Name: TS name csm no.: 100 Watertight Corrosion-Resistant Fused and Non-Fused HORSEPOWER RATINGS Cooper Crouse-Hinds Catalog Number WSRD33542SMS901 WSRDW33542SMS901 WSRDW3352SMS901 240 VAC (1 PH) 5 5 1.5 (3) 240 VAC (3 PH) 10 10 3 (7.5) 480 VAC (1 PH) 7.5 7.5 3 (7.5) 480 VAC (3 PH) 20 20 5 (15) 600 VAC (1 PH) 10 10 3 (10) 600 VAC (3 PH) 30 30 7.5 (20) 250 VDC 5 5 5 10 10 3 (10) 20 20 7.5 (15) 20 20 5 (20) 50 50 15 (30) 25 25 10 (25) 60 60 15 (50) 10 10 10 WSRD103542SMS901 100 Non-Fused 15 40 30 75 40 WSRDW103542SMS901 100 Non-Fused 15 40 30 75 40 WSRDW10352SMS901 100 Fused 7.5 (15) 15 (30) 10 (30) 25 (60) 15 (40) NOTE: Values for Non-Fused units are maximum horsepower. Values for Fused units are standard horsepower with standard fuse and (maximum horsepower with time delay). 100 100 30 (75) 20 20 20 WSRD63542SMS901 WSRDW63542SMS901 WSRDW6352SMS901 Amps Fusing 30 Non-Fused 30 Non-Fused 30 Fused 60 60 60 Non-Fused Non-Fused Fused DIMENSIONS (Inches) 1022 STIBOINFO((CRH:66008com:3P:1022)) CH0 0 4 F - 5 US: 1-866-764-5454 Amps A B C D E 30 60 5.47 7.99 16.49 18.49 23.49 25.49 9.00 11.52 8.61 8.61 100 8.47 24.18 31.18 12.00 8.61 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100