WATT HOUR TRANSDUCERS WATTHOUR TRANSDUCER MODEL WL55 FEATURES • Low Cost • Small Physical Size • + 0.5% Accuracy • Self Powered • Solid State Relay Output/LED Indicator • Diagnostic LED Status APPLICATIONS WATT HOUR TRANSDUCERS Monitoring Examples • Motor Loads • Chillers • HVAC Systems • Sub Metering ORDERING INFORMATION Example: 480V L-L, 200A, 3 Phase 3 Wire WL55-346 WL55-343 VOLTAGE NOMINAL CURRENT RANGE F.S. KWH INPUT OUTPUT* THREE PHASE THREE WIRE or FOUR WIRE (3 ELEMENT) 120 L-L 240 L-L 120 L-N (120/208) 0-5A (USE WITH 2.1KW EXTERNAL CT'S) WL55-346 VOLTAGE NOMINAL CURRENT RANGE THREE PHASE THREE WIRE or FOUR WIRE (3 ELEMENT) 480 L-L 277 L-N (277/480) 0-5A (USE WITH 4.2KW EXTERNAL CT'S) WL50 OPTIONS 8" X 10" X 6" Enclosure 0.005* (5WH) F.S. KWH INPUT OUTPUT* KWH Counter 0.005* (5WH) KYZ Relay........................ Add Suffix K to Model Number Analog Watt Output Options 0-1mAdc.......................... Add Suffix B to model number 0-10Vdc...........................Add Suffix D to model number 0-5Vdc........................... Add Suffix X5 to model number 4-20mAdc........................ Add Suffix E to model number * Standard: Pulse Output. Optional: KYZ - Relay Change of State To calculate scaling with different current transformer ratios, multiply the CT ratio by 0.005 kWh. Example 100:5 ratio CT's Ratio = 100:5 = 20:1 20 X 0.005 = 0.1kWh SPECIFICATIONS INPUT Voltage.......................................................................See Table Measurement Range.........................+20% of nominal input Over range.......... 150V, 300V, or 600V depending on model Current.......................................................................See Table Over range..................................................... 150% of range Frequency.................................................................... 50/60Hz Power Factor...............................................0.5 Lead to 0.5 Lag Burden Voltage......................................................... 0.4VA per line Current...................................................................... 2.5VA Instrument Power...................................................... 2.5VA Dielectric Test....(Input/Output/Case)...........................1500Vac Termination..........................................................14 AWG max. Div. Morlan & Associates, Inc. 4970 Scioto Darby Rd. Hilliard, Ohio 43026 OUTPUT ACCURACY................................................. + 0.5% F.S. Includes linearity,repeatability and setpoint KWH Relay Type.............Standard.............. Form A, Solid State Contact ......................................................... 120V, 0.3A, 10VA max. Type.............(Optional)................. Solid State, Form C, KYZ .....................Scaling..............................................See Table .....................Duration.................................................200ms Temperature Effect.......... (0OC to +50OC)................ +0.03%/OC Optional Analog Watt Output: Loading (Ohms) 1mAdc...................................................... <10K 5Vdc, 10Vdc............................................... >2K 4-20mAdc................................................. <500 Weight.......................................................................... 2.0 Lbs. WWW.FLEX-CORE.COM sales@flex-core.com 146 PHONE (614) 889-6152 TECH. ASSISTANCE (614) 876-8308 FAX # (614) 876-8538 WATT HOUR TRANSDUCERS CONNECTION DIAGRAMS/SPECS MODEL WL55 CASE DIMENSIONS 0.19 7.00 11 12 13 14 15 16 1 2 3 4.00 4 5 6 7 8 9 10 2.50 0.75 MOUNTING HOLES, .188" DIA., 6 PLCS. 0.344" DIA., 3 PLCS. 2.13 1.00 7.38 All Dimensions In Inches CONNECTION DIAGRAMS THREE PHASE, THREE WIRE (120/240/480Vac LINE to LINE) LINE L1 L2 L3 X1 X1 L1 L2 3 L3 4 5 6 7 8 9 10 N CT1 CT2 WL55-343 (120/240Vac) 11 12 13 14 15 16 WL55-346 (480Vac) LINE with KYZ OPTION - L1 L2 L3 N WH PULSE OUTPUT + ANALOG WATT OUTPUT (OPTIONAL) X1 X1 X1 CT3 THREE PHASE, FOUR WIRE (120/208Vac or 277/480Vac) 1 L1 2 L2 3 L3 4 5 6 7 8 9 10 N CT1 CT2 WL55-343 (120/208Vac) K Y Z with KYZ OPTION 11 12 13 14 15 16 WL55-346 (277/480Vac) - WH PULSE OUTPUT + ANALOG WATT OUTPUT (OPTIONAL) CT3 LOAD LOAD Do not unplug the CT1, CT2, CT3 terminal block while CT's are connected to a live circuit. VOLTAGE (GREEN LEDS) VOLTAGE >266V L-N >460V L-L #1 #2 #3 CURRENT (RED LEDS) #1 #2 #3 ON ON ON N/A N/A N/A CONSUMED ENERGY KWH PULSE ONLY (RED LEDS) RELAY OFF/RELAY ON WH OFF/ON Div. Morlan & Associates, Inc. VOLTAGE VOLTAGE >177V L-N <265V L-N >85V L-N <176V L-N >306V L-L <459V L-L >147V L-L <305V L-L ON BLINK OFF ON BLINK OFF ON BLINK OFF GOOD CT CONNECTION ON ON ON 4970 Scioto Darby Rd. Hilliard, Ohio 43026 OFF BLINK ON OFF BLINK ON OFF BLINK ON CT REVERSED OFF BLINK ON OFF BLINK ON OFF BLINK ON LOW or MISSING VOLTAGE <85V L-N <145V L-L OFF OFF OFF NO LOAD CURRENT OFF OFF OFF WWW.FLEX-CORE.COM sales@flex-core.com 147 WL55 Diagnostics The WL55 has a set of 7 Light Emitting Diodes (LED) to aid in diagnosing problems with connections. There are 3 green LED's for voltage, 3 red LED's for current, and 1 red LED for watt-hours. LED indicators are as shown. *CAUTION To prevent damages to power lines, transducer or personnel, NEVER connect the current inputs directly to the line. Use 600Vac rated current transformers with 5A secondary. PHONE (614) 889-6152 TECH. ASSISTANCE (614) 876-8308 FAX # (614) 876-8538 WATT HOUR TRANSDUCERS X1 1 2 K Y Z