SPECIFICATION SHEET MODEL HRV700 INDOOR POOL HEAT RECOVERY VENTILATOR FEATURES TYPICAL SPECIFICATIONS BLOWER: Fresh and stale air streams are isolated from each other to prevent mixing of stale air with fresh air High pressure, centrifugal blower accommodates many ducting configurations Balanced centrifugal blower wheels for quiet operation and long motor life Energy efficient two-speed PSC motors with sealed ball bearings, polyurethane paint and stainless steel shafts 1075/600 rpm, 115 VAC, 60 Hz, 2.5 amps each The Heat Recovery Ventilator shall be Broan-NuTone Model HRV700. HOUSING: Rugged steel housing with baked powder coated finish Installed suspended Every part is removable in less than five minutes Square inlets and outlets for easy duct connections Flanges on outdoor air stream connections allow for taping insulated ductwork All inside surfaces covered with foil-faced thermal/acoustic insulation Easily removable, washable air filters Built-in drain tube connection All interior surfaces to be covered with foil-faced thermal/ acoustic insulation. CONTROLS: Off/Low/High switch on side of unit Provisions for 24 volt low voltage control Fully enclosed, modular controls mounted to outside of cabinet for improved reliability and easy servicing Rated air flow shall be 650 cfm at 0.4 in. wg. Unit to include easily-removable energy recovery core - no tools should be required to remove. Fresh air and stale air streams to be isolated from each other to prevent mixing of stale air with fresh air. Built-in defrost mechanism to be provided to prevent freeze-ups. Every part shall be removable in less than five minutes. Housing shall be of rugged steel with baked powder coated finish. Unit shall include easily removable, washable air filters. No tools are to be required for filter cleaning/replacement. The controls are to be mounted outside of the unit and include an off/low/high switch and provisions for low voltage controls. Unit to accommodate square duct. Taping flanges on outdoor air stream connections shall be provided. Blower shall be energy efficient, two-speed PSC motors with sealed ball bearings, polyurethane paint and stainless steel shaft. Unit to be ETL listed and cETL certified. CORE: Non-enthalpic core transfers energy without moisture vapor transfer Easily removable for cleaning and replacement - no tools required Material is U.L. flammability classified 94 HB. Broan-NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1-800-637-1453) REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date 99042561C PERFORMANCE RATINGS MODEL HRV700 HEAT RECOVERY VENTILATOR 1.875"(48mm) 14.000" (356mm) 2.000" (51mm) 8.000"(203mm) Option Installed: Defrost Electrical Requirements: 115 Volts 2.5 Amps Defrost Air Port 3.625"(92mm) 2.750"(70mm) 3.750"(95mm) 8.000" (203mm) 40.500" (1029mm) 2.000" (51mm) 2.000" (51mm) 12.250" (311mm) 8.000" (203mm) Exhaust Air To Outside Fresh Air From Outside 10.750"(273mm) 2.750" (70mm) Fresh Air To Building Exhaust Air From Building 8.000"(203mm) 8.000"(203mm) 12.000"(305mm) 26.625"(676mm) to drain 10.145"(258mm) Condensate Drain 31.125"(791mm) to drain 51.000"(1295mm) A minimum of 21.00" (533mm) clearance from any obstru is required for removal of heat recovery cores, fans, door can be removed from cabinet with only 2.00" (51m A minimum of 6.00" (152mm) clearance from any obstruction is required for power hook-up, low voltage remote connection, and control panel access. 21.000"(533mm) Power Connection Low Voltage Remote Connection Heat Recovery Core Control Switch Access Door Broan-NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1-800-637-1453)