MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Introduction Filotex® Nexans’s line of microcables is designed towards the increasing requirements of electronics applications for miniaturization, reliability, performance, flexibility, higher density and EMI protection. From Medical to Instrumentation, Computers to Automated Test Equipment, Nexans offers solutions for the most demanding electronics applications. From 32 to 46 AWG, using high strength alloys and extruded fluorine resins insulation, in flat or round constructions, our development and design engineers are at your disposal to provide their experience in tailoring any of our products to meet your precise requirements. Application ü Electronics: - cables for instrumentation and test equipment applications (rack bus, positioning sensor, logic analysers,…); - cables for internal equipment or device-to-device connections. ü Computer and audio/video appliances (CD ROMto-Laptop connection, LCD panels protection, DVD connections,...). ü Ultrasound (external or internal applications for OB/Gyn, cardiology, veterinary, imaging applications,…). ü CCD cameras applications (CCD cameras for medical, industrial, endoscopy and videosurveillance applications). ü Other medical: Cardiac monitoring, pace makers, ECG/EKG,… 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 -2- Filotex® ELECTRONIC Advantages ü Wide range of conductors and dielectric materials; ü Unique patented extrusion technology for low capacitance cables; Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. ü Ultra-flexible cables; ü High speed transmission cable; ü Space and weight saving; ü High electrical performances (ε r up to 1.5) ü Various styles available; ü Good physical properties (different jacket material for mechanical, chemical and climatic requirements). Construction Single wires or coaxial cables assembled in a variety of constructions. Screened or unscreened wires available. Nexans designs round cable consisting of up to 528 elements and featuring an extremely small overall diameter of 13.0 mm/0.51”. The microcables product line includes coaxial cables with an OD as small as 0.19mm/.007”. Hook-up wires ü Singlecore unscreened from AWG 46 to AWG 32 ü Singlecore screened and jacketed from AWG 46 to AWG 32 Multicore and coaxial cables ü From 2 to 528 conductors ü From AWG 46 to AWG 32 inner conductor ü Unscreened and jacketed or screened jacketed and Composite cables Assembly of quads, pairs, coaxial… 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 -3- Filotex® ELECTRONIC Technology Inner conductor: silver plated alloy, stainless steel, silver plated copper (stranded or not) Insulation: FEP, PFA, PE (plain or special melt extrusion) Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Assembly: PTFE tape Drain wire*: silver plated alloy, silver plated copper Mechanical support*: aramid strength member in option Elect. Protection: polyester/aluminium tape, silver plated copper or alloy screen, tin plated copper screen or stainless steel screen Jacket: FEP, PFA, PVC, PUR, PE, TPE, PA * Optional Main characteristics ü Impedance : 50 Ω to 130 Ω ü Capacitance : 27 pF/m to 110 pF/m (8 pF/ft to 33pF/ft) ü Operating voltage : from 24 V to 250 V ü Operating temperature : from – 60°C to +200°C 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 -4- Filotex® ELECTRONIC Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Summary Part 1 Microcables for all markets: single coaxials - Normal capacitance: 95pF/m - Low capacitance: 55pF/m Part 2 Microcables for electronic application Page 16 Part 3 Microcables for computer application Page 20 Part 4 Microcables for ultrasound Page 23 Part 5 Microcables for CCD cameras applications - Microcables for Endoscopy - Microcables for Dental application Page 34 Page 35 Page 42 Part 6 Microcables for other medical applications - Microcables for catheter - Microcables for patient monitoring (invasive applications) - Microcables for ECG - Temporary myocard pacing wire Page 47 Page 48 Page 51 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Page 6 Page 7 Page 14 Page 53 Page 55 Issue 1 - November 2000 -5- Part 1 Microcables for all markets: single coaxials 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 -6- Normal capacitance 95pF/m All cables are also available in solid conductor version. 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 -7- Filotex STUDY 123836 32 AWG coax cable ® Micro coaxial cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 123 836 Electrical performances CONSTRUCTION Multi coax 95 pF/m • AWG 32 stranded silver plated alloy. ‚ FEP insulation ∅ = .65 ±.02mm ƒ 44 AWG silver plated copper Helicoidal screen ∅ = .75mm nominal „ FEP jacket ∅ = .91 ± .03mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen :350 V DC 1 mn Thermal performances r Operating temperature : - 50°C to + 200 °C Mechanical performances r Minimum bending radius : 5 x Overall diameter . Standard colours r Dielectric : Black – Brown - Red - Orange - Yellow - Green - Blue Violet - Grey - White – Translucide r Jacket : White ¬ - ® ¯ Issue 1 - November 2000 -8- Filotex STUDY 132474 34 AWG coax cable ® Micro coaxial cable Characteristics Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. r Very flexible cable with an extremely good mechanical behaviour. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 132 474 Electrical performances CONSTRUCTION Multi coax 95 pF/m • 34 AWG(7 x .06 mm) stranded silver plated copper ‚ PFA insulation ∅ = .53 ± .02mm ƒ 44 AWG silver plated copper braid Helicoidal screen ∅ = .75mm nominal „ PFA jacket ∅ = .85 ± .03 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen :350 V DC 1 mn Thermal performances r Operating temperature : - 50°C to + 200°C Mechanical performances r Minimum bending radius : 5 x Overall diameter . Standard colours r Dielectric : Green r Jacket : Black - Brown - Red - Orange – Yellow - Green - Blue Violet - Grey - White – Translucide Issue 1 - November 2000 -9- Filotex STUDY 124954 36 AWG coax cable ® Micro coaxial cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r Ultrasound cable assemblies. Electrical performances PRODUCT REFERENCES FILOTEX Ref : ET 124 954 r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r CONSTRUCTION Multi coax 95 Pf/M • AWG 36 stranded silver plated copper. ‚ FEP insulation ∅ = .44 ± 02mm ƒ 44 AWG silver plated copper Helicoidal screen ∅ = .54mm nominal „ Operating temperature : - 50°C to + 200 °C Mechanical performances r Minimum bending radius : 5 x Overall diameter . Standard colours r Dielectric : Red or Green r Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue Violet - Grey - White - Translucide ¬ - ® ¯ FEP jacket ∅ = .63 ± .03 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 10 - Filotex STUDY 122882 38 AWG coax cable ® Micro coaxial cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics PRODUCT REFERENCES FILOTEX Ref : ET 122 882 CONSTRUCTION Multi coax 95pF/m • AWG 38 stranded silver plated alloy ‚ FEP insulation ∅ = .34 ± .02mm ƒ 44 AWG silver plated copper Helicoidal screen ∅ = 44mm nominal „ FEP jacket ∅ = .53 ± .02mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Very flexible cable with an extremely good mechanical behaviour r Withstands miscellaneous sterilisation processes Applications r Ultrasound cable assemblies Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 50°C to + 200 °C Mechanical performances r Minimum bending radius : 5 x Overall diameter . Standard colors r Dielectric : Red or Green r Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue Violet - Gray - White - Translucide ¬ - ® ¯ Issue 1 - November 2000 - 11 - Filotex STUDY 132469 40 AWG coax cable ® Micro coaxial cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 132 469 Electrical performances CONSTRUCTION Multi coax 95 pF/m • AWG 40 silver plated alloy 135 wire ‚ PFA insulation. ∅ = .23 ± 02mm ƒ 48 AWG silver plated copper Helicoidal screen ∅ = .29mm nominal „ PFA jacket ∅ = .36 ± .03 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen :350 V DC 1 mn Thermal performances r Operating temperature : - 50°C to + 200°C Mechanical performances r Minimum bending radius : 5 x Overall diameter . Standard colours r Dielectric : Green r Jacket : Black - Brown - Red - Orange – Yellow - Green - Blue Violet - Grey - White – Translucide ¬ - ® ¯ Issue 1 - November 2000 - 12 - Filotex STUDY 132358 42 AWG coax cable ® Micro coaxial cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 132 358 Electrical performances CONSTRUCTION Multi coax 95 pF/m r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen :350 V DC 1 mn Thermal performances r Operating temperature Mechanical performances • AWG 42 stranded silver plated alloy r ‚ PFA insulation ∅ = .21mm Standard colours ƒ 48 AWG silver plated copper Helicoidal screen ∅ = .27mm nominal „ FEP jacket ∅ = .35 ± .03 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 : - 50°C to + 200°C Minimum bending radius : 5 x Overall diameter . r Dielectric : Green r Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue Violet - Grey - White - Translucide ¬ - ® ¯ Issue 1 - November 2000 - 13 - Low capacitance 55pF/m All cables are also available in solid conductor version. 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 14 - Filotex STUDY 132475 40 AWG coax cable ® Micro coaxial cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 132 475 Electrical performances CONSTRUCTION Multi coax 55 pF/m • AWG 40 silver plated alloy 135 wire ‚ PFA “SE” insulation ∅ = .36 ± .02mm ƒ 48 AWG silver plated copper Helicoidal screen ∅ = .42mm nominal „ PFA jacket ∅ = .47 ± .03 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance : 80 Ω nominal r Linear capacitance : 55 ± 5 pF/m (at 95%)(17pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn r Max DC resistance : 1.2 Ω/ft Thermal performances r Operating temperature : - 50°C to + 200°C Mechanical performances r Minimum bending radius : 5 x Overall diameter . Standard colours r Dielectric : Red r Jacket : Black - Brown - Red - Orange – Yellow - Green – Blue Violet – Grey - White – Translucide ¬ - ® ¯ Issue 1 - November 2000 - 15 - Part 2 Microcables for electronic application Linear capacitance : ET 132211 27pF/m ET 132084 33pF/m ET 124810 55pF/m 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 16 - Filotex STUDY 132211 41 AWG coax cable ® Cable for electronic application Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics PRODUCT REFERENCES FILOTEX Ref : ET 132 211 CONSTRUCTION Coax 130 Ω r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Electrical performances r Characteristic impedance : 130 ± 10 Ω r Max linear capacitance : 27 pF/m (8 pF/ft) r DC resistance : 130 ± 8 Ω/m r Continuous operating voltage : 30 V eff. r Test voltage between core and screen :350 V DC 1 mn Thermal performances r Operating temperature Mechanical performances • AWG 41 constantan r ‚ FEP “SE” insulation ∅ = .95 ±.05mm Standard colours ƒ 44 AWG silver plated copper Helicoidal screen ∅ = 1.05mm nominal „ PVC jacket ∅ = 1.40mm max 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 : - 50°C to + 80°C Minimum bending radius r Dielectric : Yellow r Jacket : Flint Grey ¬ - : 5 x Overall diameter . ® ¯ Issue 1 - November 2000 - 17 - Filotex STUDY 132084 41 AWG coax cable ® Cable for electronic application Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics PRODUCT REFERENCES FILOTEX Ref : ET 132 084 CONSTRUCTION Coax 130 Ω r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Electrical performances r Characteristic impedance : 130 ± 10 Ω r Linear capacitance : 33 ± 3 pF/m (10pF/ft) r DC resistance : 130 ± 8 Ω/m r Continuous operating voltage : 30 V eff. r Test voltage between core and screen :350 V DC 1 mn Thermal performances r Operating temperature Mechanical performances • AWG 41constantan r ‚ FEP “SE” insulation ∅ = .70 ±.03mm Standard colours ƒ 44 AWG silver plated copper Helicoidal screen ∅ = .80mm nominal „ PVC jacket ∅ = 1.1 ± .05mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 : - 50°C to + 80°C Minimum bending radius r Dielectric : Red r Jacket :Flint Grey ¬ - : 5 x Overall diameter . ® ¯ Issue 1 - November 2000 - 18 - Filotex STUDY 124810 4 channels 38 AWG coax cable ® Cable for electronic application Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Cable for displacement sensor. PRODUCT REFERENCES r FILOTEX Ref : ET 124 810 Electrical performances r Characteristic impedance : 80 Ω nominal r Linear capacitance : 55 ± 5 pF/m (at 95%).(17pF/ft) r Current capacity : > 250 mA r Continuous operating voltage : 250 V DC. Thermal performances CONSTRUCTION r Multi coax 55 pF/m Operating temperature : - 20°C to + 75 °C Mechanical performances Core A : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .51 ± 02mm AWG 48 silver plated copper Helicoidal screen ∅ = .57mm nominal FEP jacket ∅ = .62 ± 02mm 4 Cores A twisted ∅ = 1.5mm • ‚ PTFE ∅ = 1.55mm nominal ƒ AWG 41 tin plated copper braid 90 % coverage ∅ = 1.8mm nominal „ Medical P.V.C ∅ = 2.8 ± .15mm r Minimum bending radius : 5 x Overall diameter tape 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 19 - Part 3 Microcables for computer application Linear capacitance : ET 132433 55 pF/m ET 132167 100 pF/m 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 20 - Filotex STUDY 132433 49 channels 42 AWG coax cable + 8 x 28 AWG wires ® Cable for computer application (input/output) Characteristics Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. r Very flexible cable with an extremely good mechanical behaviour. Electrical performances PRODUCT REFERENCES FILOTEX Ref : ET 132 433 CONSTRUCTION Multi coax 55 pF/m • Core A : AWG 42 (1 x 0.064 mm) silver plated Alloy. PFA " SE " insulation ∅ = .26 ± .02mm AWG 48 silver plated copper Helicoidal screen ∅ = .32 mm nominal PFA jacket ∅ = .36 ± .02mm ‚ Core B : AWG 28 (7 x 0.13 mm) stranded tin plated copper. PFA insulation ∅ = .59 ± .03 mm ƒ Core C : 8 Cores A twisted ∅ = 1.1 mm „ Core D : 9 Cores A twisted ∅ = 1.3 mm 5 cores (C) + 1 cores (D) + 8 cores (B) twisted ∅ = 4.0 mm nominal … PTFE tape ∅ = 4.06 mm nominal. † AWG 40 tin plated copper braid 85 % coverage ∅ = 4.40 mm nominal ‡ PVC jacket ∅ = 5.9 ± .2 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance cores A : 80 Ω nominal r Linear capacitance cores A : 55 ± 5 pF/m (at 95%).(17 pF/ft) r DC resistance cores A : <= 7.8 Ω/m (2.5 Ω/ft) r Continuous operating voltage cores A : 24 V eff. r Continuous operating voltage cores B : 250 V DC r DC resistance cores B : <= .25 Ω/m (.076 Ω/ft) r Test voltage between core and screen : 350 V DC 1 mn r Insulation resistance : > 1000 MΩ.km Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 21 - C Filotex STUDY 132167 49 channels 42 AWG coax cable + 8 x 28 AWG wires ® Cable for computer application (input/output) Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Electrical performances PRODUCT REFERENCES FILOTEX Ref : ET 132 167 CONSTRUCTION Multi coax 100 pF/m • Core A : AWG 42 (1 x 0.064 mm) silver plated Copper. FEP insulation ∅ = .19 ± .02mm AWG 48 tin plated copper Helicoidal screen ∅ = .25mm nominal FEP jacket ∅ = .30 ± .02mm ‚ Core B : AWG 28 (7 x 0.13 mm) stranded tin plated copper. FEP insulation ∅ = .59 ± .03mm ƒ Core C : 8 Cores A twisted ∅ = 0.9mm „ Core D : 9 Cores A twisted ∅ = 1.1mm 5 cores (C) + 1 cores (D) + 8 cores B twisted ∅ = 3.75mm nominal … PTFE tape ∅ = 3.8mm nominal. † AWG 40 tin plated copper braid 85 % coverage ∅ = 4.15mm nominal ‡ PVC jacket ∅ = 5.5 ± .2mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance cores A : 50 Ω nominal r Linear capacitance cores A : 100 ± 10 pF/m (at 95%).(30.5pF/ft) r DC resistance cores A : <= 7.8 Ω/m r Continuous operating voltage cores A : 24 V eff. r Continuous operating voltage cores B : 250 V DC r DC resistance cores B : <= .25 Ω/m r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 22 - Part 4 Microcables for Ultrasound Applications : q Veterinary application (mechanical probes) q Transvaginal application q Endocavity application 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 23 - Filotex STUDY 124311 11 channels 34 AWG coax + 8 x 26 AWG wires ® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r Ultrasound cable assemblies. Electrical performances PRODUCT REFERENCES FILOTEX Ref : ET 124 311 r Characteristic impedance core (A) : 50 nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r CONSTRUCTION Ultra sound cable • ‚ ƒ „ … † ‡ Core A : AWG 34 stranded silver plated alloy. PTFE insulation ∅ = .52 ±.02mm AWG 43 silver plated copper braid FEP jacket ∅ = 1.02 ±.05 mm Core B : AWG 26 stranded tin plated copper. PVC insulation ∅ = .90 ±.10mm Fillers 7 cores (A) + 1 filler twisted AWG 40 tin plated copper helicoidal screen 90 % coverage 4 cores (A) + 8 cores (B) + fillers twisted around PTFE tape AWG 40 tin plated copper braid 95 % coverage Medical PVC ∅ = 7.45 ±3mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances q Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 24 - Filotex STUDY 124973 26 channels 36 AWG coax cable + 20 wires 30 AWG ® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 124 973 Electrical performances CONSTRUCTION Multi coax 95 pF/m • ‚ ƒ „ … † ‡ ˆ ‰ Core A : AWG 36 stranded silver plated copper. FEP insulation ∅ = .44 ±.03mm AWG 44 silver plated copper Helicoidal screen ∅ = .54mm nominal FEP jacket ∅ = .63 ± .03 mm Core B: AWG 30 stranded silver plated copper. FEP insulation ∅ = .5 ± 1mm Core C: 3 cores A twisted Core D: 4 cores B twisted Core E: 3 cores B twisted Core F: 2 cores A + 1 core B twisted 8 Cores (C) + 4 cores D + 1 core E + 1 core F twisted ∅ = 5.2 mm nominal PTFE tape ∅ = 5.25 mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 5.6mm nominal Medical PVC ∅ = 7.0 ± .3mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance core (A) : 50 nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn r DC resistance core (A) : 1.5 Ω/m r DC resistance core (B) : .4 Ω/m Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 25 - STUDY 124733 33 channels 40 AWG coax + 12 x 36 AWG wires Filotex® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. PRODUCT REFERENCES FILOTEX Ref : ET 124 733 Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r CONSTRUCTION Ultrasound cable • Core A : AWG 40 stranded silver plated alloy. FEP insulation ∅ = .25 ± .02 mm AWG 48 silver plated copper Helicoidal screen ∅ = .31 mm nominal FEP jacket ∅ = .39 ± .02 mm ‚ Core B : AWG 36 stranded silver plated. FEP insulation ∅ = .40 ± .02mm ƒ Core (C) 7 cores (A) twisted „ Core (D) 6 cores (B) +Cotton filler twisted … Core (E) 5 cores (A) +Cotton filler twisted 4 Cores (C) + 2 cores (D) + 1 core (E) twisted ∅ = 3.50 mm nominal † PTFE tape ∅ = 3.7 mm nominal. Ultrasound cable assemblies. Electrical performances r Characteristic impedance core (A) : 50 Ω nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Mechanical performances r Minimum bending radius : 5 x Overall diameter ‡ AWG 44 tin plated copper braid 85 % coverage ∅ = 3.9 mm nominal ˆ Medical PVC ∅ = 4.9 ± .1mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 26 - STUDY 123992 66 channels 38 AWG coax cable Filotex® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 123 992 Electrical performances CONSTRUCTION Multi coax 95 pF/m • Core A : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .34 ±.02mm AWG 44 silver plated copper Helicoidal screen ∅ = .44mm nominal FEP jacket ∅ = .53 ± .02mm ‚ Core B : 8 Cores A twisted ∅ = 1.6mm ƒ Core C : 2 Cores A twisted ∅ = 1.05mm 8 cores (B) + 1 cores (C) twisted ∅ = 5.3mm nominal „ PTFE tape ∅ = 5.35mm nominal. … AWG 40 tin plated copper braid.85 % coverage ∅ = 5.7mm nominal † Medical P.V.C ∅ = 8 ± .2mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance : 50 nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 27 - Filotex STUDY 124480 84 channels 38 AWG coax cable ® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications PRODUCT REFERENCES r Ultrasound cable assemblies. Electrical performances FILOTEX Ref : ET 124 480 r Characteristic impedance : 50 nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r CONSTRUCTION • ‚ ƒ „ … † Multi coax 95 pF/m Core A : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .34 ±.02mm AWG 44 silver plated copper Helicoidal screen ∅ = 44mm nominal FEP jacket ∅ = .53 ± .02mm Core B : 8 Cores A twisted ∅ = 1.6mm Core C : 2 Cores A twisted ∅ = 1.05mm 10 cores (B) + 2 cores (C) twisted ∅ = 6.0mm nominal PTFE tape ∅ = 6.05 mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 6.4mm nominal Medical P.V.C ∅ = 8.0 ±.2mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter r Flex life test : Standard test in accordance with drawing 250,000 cycles minimum Mover rollers ∅ 80 mm Moving range : 550 mm Cable length Speed Test weight (M) : 1600 mm : .22 m/s (8 cycles/mn) : 3000 g Issue 1 - November 2000 - 28 - Filotex STUDY 124499 132 channels 38 AWG coax cable ® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 124 499 Electrical performances CONSTRUCTION Multi coax 95 pF/m Core A : AWG 38 silver plated copper wire. FEP insulation ∅ = .30 ±.02mm AWG 48 silver plated copper Helicoidal screen ∅ = .36mm nominal FEP jacket ∅ = .46 ± .02mm ‚ Core B : 4 Cores A twisted ∅ = 1.1mm ƒ Core C : 8 Cores A twisted ∅ = 1.4mm 1 cores (B) + 16 cores (C) twisted ∅ = 6.5mm nominal „ PTFE tape ∅ = 6.6mm nominal. … AWG 41 tin plated copper braid 85 % coverage ∅ = 7.0mm nominal • 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 29 - Filotex STUDY 132029 132 channels 40 AWG coax cable ® Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Medical Ultrasound cable Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications PRODUCT REFERENCES r Ultrasound cable assemblies. r FILOTEX Ref : ET 132 029 Electrical performances r Characteristic impedance : 80 Ω nominal r Linear capacitance : 55 ± 5 pF/m (at 95%).(17pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V AC 1 mn r Max DC resistance of centre conductor : 1.2 Ω/ft CONSTRUCTION Multi coax 55pF/m • ‚ ƒ „ … † Core A : AWG 40 stranded silver plated alloy PD 135. FEP « SE » insulation ∅ =.34 ± .03 mm AWG 48 silver plated copper Helicoidal screen ∅ =.40mm nominal FEP jacket ∅ = .46 ± .03mm Core B : 4 Cores A + Kevlar member tensile strength 50 kgF twisted ∅ = 1.15mm Core C : 8 Cores A twisted ∅ = 1.5mm 1 core (B) + 16 cores C twisted ∅ =6.3mm nominal PTFE tape ∅ = 6.35 mm nominal. AWG 40 silver plated alloy braid 85 % coverage ∅ = 6.7mm nominal Medical P.V.C ∅ = 8.5 ±.25mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 30 - Filotex STUDY 124590 132 channels 42 AWG coax cable ® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 124 590 Electrical performances CONSTRUCTION Multicoax 95 pF/m • Core A : AWG 42 silver plated copper wire. FEP insulation ∅ = .20 ± .02 mm AWG 48 silver plated copper Helicoidal screen ∅ = .26 mm nominal FEP jacket ∅ = .34 ± .02 mm r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter ‚ Core B : 4 Cores A twisted ∅ = .8 mm ƒ Core C : 8 Cores A twisted ∅ = 1 mm 1 cores (B) + 16 cores (C) twisted ∅ = 4.7 mm nominal „ PTFE tape ∅ = 4.8 mm nominal. … AWG 40 silver plated alloy braid 85 % coverage ∅ = 5.2 mm nominal † Medical P.V.C ∅ = 7.2 ± .3 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 31 - Filotex STUDY 124541 192 + 4 channels 40 AWG coax cable ® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not p ermitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r PRODUCT REFERENCES FILOTEX Ref : ET 124 541 CONSTRUCTION Multi coax 55pF/m • ‚ ƒ „ … † Core A : AWG 40 stranded 7x.03mm silver plated alloy PD 135. FEP « SE » insulation ∅ = .34 ± .02 mm AWG 48 silver plated copper Helicoidal screen ∅ =.40mm nominal FEP jacket ∅ = .46 ± .02mm Core B : 16 Cores A twisted ∅ = 2.1mm Core C : 4 Cores A twisted ∅ =.95mm 12 cores (B) + 1 core C twisted ∅ =7.7mm nominal PTFE tape ∅ = 7.75mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 8.1mm nominal Medical PVC ∅ = 9.6 ±.3mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Ultrasound cable assemblies. Electrical performances r Characteristic impedance : 80 Ω nominal r Linear capacitance : 18 ± 2 pF/ft (at 95%) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 500 V AC 1 mn r Max DC resistance of centre conductor : 1.2 Ω/ft r Max DC resistance of coax shield : 15 Ω/ft r Insulation resistance : > 10 MΩ r Crosstalk coax to coax , 1 ~ 10 Mhz in 96 inches long cable will all ends terminated in 80 Ω : < 55 dB r One way signal loss (1 ~ 10 Mhz) : < 0.10 dB/ft Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 32 - Filotex STUDY 132081 256 + 8 channels 40 AWG coax cable ® Medical Ultrasound cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 132 081 Electrical performances CONSTRUCTION Multicoax 95pF/m • Core A : AWG 40 stranded silver plated alloy. FEP insulation ∅ = .24 ± .02 mm AWG 48 silver plated copper Helicoidal screen ∅ = .3 mm nominal FEP jacket ∅ = .39 ± .02 mm r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn r DC resistance : <= 1.2 Ω/ft Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter ‚ Core B : 16 Cores A twisted ∅ = 1.9 mm ƒ Core C : 8 Cores A twisted ∅ = 1.2 mm 16 cores (B) + 1 core (C) twisted ∅ = 7.6 mm nominal „ PTFE tape ∅ = 7.65 mm nominal. … Medical P.V.C ∅ = 9.6 ± .30 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 33 - Part 5 Microcables for CCD cameras applications 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 34 - Microcables for Endoscopy Available models 3.5 mm ET 123602 5 mm ET 132468 ET 123540 ET 124991 ET 124692 7 mm ET 132028 Optional UL style approval : UL20379 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 35 - Filotex STUDY 123602 9 channels 38 AWG coax + 5 x 38 AWG wires ® Medical Video Endoscopy cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subje ct to change without notice. Characteristics PRODUCT REFERENCES FILOTEX Ref : ET 123 602 CONSTRUCTION Video camera Cable • ‚ ƒ „ … † Core A : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .34 ±.02mm AWG 44 silver plated copper Helicoidal screen ∅ = .44mm nominal FEP jacket ∅ = .53 ± .02 mm Core B : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .34 ±.05mm Fillers 9 Cores (A) + 5 cores (B) + Fillers twisted ∅ = 2.05 mm nominal PTFE tape ∅ = 2.07 mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 2.5mm nominal Medical PVC ∅ = 3.45 ±.1mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Very flexible cable with an extremely good mechanical behaviour r Withstands miscellaneous sterilisation processes Applications r Video Endoscopy cable assemblies Electrical performances r Characteristic impedance (core A) : 50 nominal r Linear capacitance (core A) : 95 ± 10 pF/m (at 95%) (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85 °C (100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter . Issue 1 - November 2000 - 36 - Filotex STUDY 132468 1 channel 30 AWG coax + 11 x 28 AWG wires ® Medical Video Endoscopy cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Video endoscopy cable assemblies PRODUCT REFERENCES r FILOTEX Ref : ET 132 468 Electrical performances r Characteristic impedance core (B and D) : 50 Ω nominal r Linear capacitance core (B and D) : 110±10 pF/m (at 95%) (33 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn CONSTRUCTION Video camera Cable • ‚ ƒ „ … † Core A : AWG 30 (19 x 42 AWG) stranded silver plated alloy. FEP insulation ∅ = .82 ±.05mm AWG 40 silver plated copper braid ∅ = 1.20mm nominal FEP jacket ∅ = 1.55 ± .05mm Core B: AWG 28 (19 x 40 AWG) stranded silver plated copper. FEP insulation ∅ = .60 ±.05mm 1 Core (A) + 11 cores (B) twisted ∅ = 2.75 mm nominal PTFE tape. ∅ = 2.90 mm nominal AWG 40 silver plated copper spiral shield ∅ = 3.25 mm nominal PTFE tape. ∅ = 3.4mm nominal Medical PVC ∅ = 5.45 ±.2mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 37 - Filotex STUDY 123540 2 channels 34 AWG coax + 5 x 28 AWG wires ® Medical Video Endoscopy cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r r Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes Applications PRODUCT REFERENCES r Video Endoscopy cable assemblies FILOTEX Ref : ET 123 540 Electrical performances CONSTRUCTION Video camera Cable • ‚ ƒ „ … Core A : AWG 34 stranded silver plated alloy. PFA insulation ∅ = .53 ±.03mm AWG 44 silver plated copper Helicoidal screen ∅ = .63mm nominal PFA jacket ∅ = .98 ± .05mm Core B : AWG 28 stranded tin plated copper. PVC insulation ∅ = 1.1 ± .05mm 2 core (A) + 5 cores (B) twisted ∅ = 3.3 mm nominal PTFE tape ∅ = 3.35 mm nominal AWG 41 tin plated copper braid 85% coverage ∅ = 3.7 mm nominal Medical PVC ∅ = 5.0±15mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Linear capacitance core (A) r DC resistance (A) Ω/100m nominal : 100 pF/m nominal : 95 Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter . Issue 1 - November 2000 - 38 - Filotex STUDY 124991 5 channels 30 AWG coax + 3 x 30 AWG wires ® Medical video Endoscopy cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Medical cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 124 991 Electrical performances r Characteristic impedance core (A) : 50 nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn CONSTRUCTION • ‚ ƒ „ … Core A : AWG 30 stranded silver plated copper. FEP insulation ∅ = .80 ±.02mm AWG 38 silver plated copper helicoidal screen ∅ = 1.0 mm nominal FEP jacket ∅ = 1.2 ± .03 mm Core B: AWG 30 stranded silver plated copper. PTFE insulation ∅ = .81 ± .05mm 5 Cores (A) + 3 cores (B) twisted ∅ = 4.05 mm nominal PTFE tape AWG 40 tin plated copper braid 85% coverage ∅ = 4.4mm nominal Polyurethane ∅ = 5.7 ± .2mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 39 - Filotex STUDY 124692 9 channels 32 AWG coax + 3 x 26 AWG wires ® Medical Video Endoscopy cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Video endoscopy cable assemblies PRODUCT REFERENCES r FILOTEX Ref : ET 124 692 Electrical performances CONSTRUCTION Video camera Cable • ‚ ƒ „ … Core A : AWG 32 stranded silver plated alloy. FEP insulation ∅ = .65 ±.03mm AWG 44 silver plated copper Helicoidal screen ∅ = .75mm nominal FEP jacket ∅ = .91 ± .05mm Core B : AWG 26 stranded tin plated copper. FEP insulation ∅ = .81 ±.05mm 9 Cores (A) + 3 cores (B) twisted ∅ = 3.6mm nominal PTFE tape ∅ = 3.65mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 4.1mm nominal Medical PVC ∅ = 5.0 ± .2mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Characteristic impedance core (A) : 50 nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 40 - STUDY 132028 3 channels 28 AWG coax 6 channels 32 AWG coax + 3 x 26 AWG wires Filotex® Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Medical Video Endoscopy cable Characteristics q Very flexible cable with an extremly good mechanical behaviour. q PRODUCT REFERENCES FILOTEX Ref : ET 132 028 CONSTRUCTION Withstands miscellaneous sterilization processes. Applications q Video endoscopy cable assemblies. Electrical performances q Characteristic impedance core (A) : 50 nominal q Linear capacitance core (A) : 80 pF/m nominal q Characteristic impedance core (B) : 50 nominal q Linear capacitance core (B) : 95 pF/m nominal q Continuous operating voltage : 30 V eff. q Test voltage between core and screen : 500 V AC 1 mn Thermal performances q Operating temperature : - 30°C to + 85 °C (100 °C at peak) Video Camera Cable • Core A : AWG 28 stranded silver plated alloy. FEP insulation ∅ = 1.1 ± .05 mm AWG 40 silver plated copper Helicoidal screen ∅ = 1.26 mm nominal FEP jacket ∅ = 1.58 ± .05 mm ‚ Core B : AWG 32 stranded silver plated alloy. FEP insulation ∅ = .63 ± .05 mm AWG 44 silver plated copper Helicoidal screen ∅ = .73 mm nominal FEP jacket ∅ = .91 ± .05 mm ƒ Core C : AWG 26 stranded silver plated copper. FEP insulation ∅ = .80 ± .05 mm „ Cotton filler Mechanical performances q Minimum bending radius : 5 x Overall diameter 3 Cores (A) + 6 cores (B) + 3 cores (C) twisted ∅ = 4.4 mm nominal … PTFE tape ∅ = 4.45 mm nominal. † AWG 40 tin plated copper braid 85 % coverage ∅ = 4.8 mm nominal ‡ Medical PVC ∅ = 6.8 ± .2 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 41 - Microcables for Dental application 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 42 - STUDY 124844 1 channels 34 AWG coax + 8 x 34 AWG wires + 2 x 30 AWG wires Filotex® Dental cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Video endoscopy cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 124 844 Electrical performances r Linear capacitance core (A) : 100 pF/m nominal r DC resistance core (A) : 95 r Ω /100m nominal DC resistance core (B) : 33.7 Ω /100m nominal DC resistance core (C) : 95 Ω /100m nominal r Test voltage between braid and outside : 4000 V AC 1 mn r CONSTRUCTION Video camera Cable • Core A : AWG 34 stranded silver plated alloy. PFA insulation ∅ = .53 ±.03mm AWG 44 silver plated copper Helicoidal screen nominal ∅ = .63mm PFA jacket ∅ = .83 ± .05mm ‚ Core B : AWG 30 stranded silver plated alloy. PFA insulation ∅ = .50 ± .05mm ƒ Core C : AWG 34 stranded silver plated alloy. PFA insulation ∅ = .36 ±.05mm 1 core (A) + 2 cores (B) + 8 cores (C) twisted ∅ = 2.05mm nominal „ 34 AWG silver plated alloy Drain wire … PTFE tape ∅ = 2.10 mm nominal † AWG 40 silver plated alloy braid 85 % coverage ∅ = 2.60 mm nominal ‡ Medical PVC ∅ = 4.1 ± .15mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 43 - STUDY 132331 2 channels 36AWG coax + 9 x 32 AWG wires + 10 x 32 AWG wires Filotex® Dental cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics PRODUCT REFERENCES FILOTEX Ref : ET 132 331 CONSTRUCTION Video camera Cable • ‚ ƒ „ … † ‡ ˆ ‰ Core A : AWG 36 stranded silver plated alloy PFA insulation ∅ = .52 ± .03mm AWG 44 silver plated copper Helicoidal screen ∅ =.62mm nominal PFA jacket ∅ = .72 ± .05mm Core B : AWG 32 stranded silver plated alloy PFA insulation ∅ = .42 ± .05mm 2 cores (A) + 9 cores (B) twisted ∅ = .2.3 nominal PTFE tape ∅ 2.35 mm nominal. AWG 40 silver plated copper braid 85% coverage ∅ = 2.7mm nominal 2 Medical PTFE tapes ∅ =3.2 ± 3.2mm max Optional fillers 10 cores (B) around ∅ = 4.05mm PTFE tape ∅ = 4.1mm nominal Medical PVC ∅ = 5.3 ± .2mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r Very flexible cable with an extremely good mechanical behaviour r Withstands miscellaneous sterilisation processes Applications r Video endoscopy cable assemblies Electrical performances r Characteristic impedance : 60 nominal r Linear capacitance : 80pF/m nominal r Continuous operating voltage : 24 V eff. r DC resistance core (A) : 150 Ω/100m r DC resistance core (B) : 600 Ω/100m r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85 °C (100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter 9 8 7 6 5 4 3 2 1 Issue 1 - November 2000 - 44 - STUDY 132116 2 x 36 AWG twisted pairs + 14 x 36 AWG wires Filotex® Dental cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Video endoscopy cable assemblies. PRODUCT REFERENCES r FILOTEX Ref : ET 132 116 Electrical performances • ‚ ƒ „ … † ‡ ˆ r Linear capacitance core (C) : 63 pF/m nominal r Linear capacitance between 2 cores (B) : 43 pF/m nominal r Linear capacitance between cores (B) and braid : 80 pF/mnominal r All capitance must be verify on a sample r DC resistance core (A) and (B) : 2.07 CONSTRUCTION r Test voltage between braid and outside : 500 V AC Video camera Cable r Spark test of jacket : 1500 V AC Core A : AWG 36 stranded silver plated alloy. FEP insulation ∅ = .24 ±.03mm Core B : AWG 36 stranded silver plated alloy. FEP insulation ∅ = .28 ±.05mm Core C : 2 cores (A) twisted, pitch 5mm nominal (8 mm maxi) Kevlar member 158 TEX Tensile strength > 20 kgF 2 core (C) + 14 cores (B) + Kevlar member twisted, pitch 10mm nominal ∅ = 1.7mm max PTFE tape AWG 40 silver plated alloy braid 95 % coverage , pitch 10mm nominal ∅ = 2.2mm nominal PTFE tape ∅ = 2.4mm max Polyurethane ∅ = 3.6mm max Thickness .60 ± .05 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Ω /m nominal 2.2 Ω /m max Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000 - 45 - Filotex STUDY 132182 8 x 36 AWG twisted pairs + 3 x 36 AWG wires ® Dental cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r Video endoscopy cable assemblies Electrical performances PRODUCT REFERENCES FILOTEX Ref : ET 132182 r Linear capacitance core (C) : 60 pF/m maxi r Linear capacitance between 2 cores (B) : 15 pF/m nominal r Linear capacitance between cores (C) and braid : To be define on sample CONSTRUCTION Video camera Cable • Core A :AWG 36 stranded silver plated alloy. FEP insulation ∅ = .24 ± .03mm ‚ Core B :AWG 36 stranded silver plated alloy. FEP insulation ∅ = .28 ± .05mm ƒ Core C : 2 cores (A) twisted, pitch 8mm nominal(10 mm maxi) „ Kevlar member 158 TEX Tensile strength > 20 kgF … Core D : 3 cores (B) twisted + Kevlar member, pitch 9mm nominal (12mm maxi) 1 core (D) + 8 cores (C) twisted, pitch 15 to 25mm ∅ = 1.7mm max † PTFE tape unsintered ‡ AWG 42 hard silver plated alloy braid 95 % coverage , pitch 10mm nominal ∅ = 2.15mm nominal ˆ PTFE tape unsintered ∅ = 2.35mm max ‰ Polyurethane ∅ = 3.6mm max Thickness .60 ± .05mm All copper alloy are without cadmium. 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r All capacitance must be verify on a sample r DC resistance core (A) & (B) : 1.52 r Test voltage conductor/conductor : 500 VAC r Spark test of jacket : 1500 VAC Ω /m nominal . 1.6 Ω /m max. Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter 9 8 7 6 5 4 3 2 1 Issue 1 - November 2000 - 46 - Part 6 Microcables for other medical applications 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 47 - Microcables for Catheter 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 48 - Filotex STUDY 132183 3 x 2 wires 44 AWG ® Cable for catheter Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications Ultrasound cable assemblies PRODUCT REFERENCES r FILOTEX Ref : ET 132 183 Electrical performances r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r CONSTRUCTION • Core A : AWG 44 silver plated copper. Enamel lacquer ∅ =.06 ±.005 mm ‚ Core B : 2 cores A twisted ∅ =.12mm Operating temperature : - 30°C to +150 °C (200°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter 3 cores (B) twisted ∅ =.22mm nominal ƒ AWG 48 silver plated copper spiral shield ∅ = .28mm nominal „ FEP ∅ = .40 ± .02 mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 49 - Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Filotex STUDY 124524 5 x 30 AWG wires ® Cable for catheter Characteristics PRODUCT REFERENCES r Very flexible cable with an extremely good mechanical behaviour. FILOTEX Ref : ET 124 524 Electrical performances r Continuous operating voltage : 250 V Thermal performances r CONSTRUCTION • ‚ ƒ „ … † Operating temperature : - 60°C to +85 °C Mechanical performances r Minimum bending radius : 5 x Overall diameter Core A : AWG 30 stranded silver plated copper. PTFE insulation ∅ = .61 ±.05mm Core B : AWG 30 stranded silver plated copper drain wire. Core C : 2 cores (A) + 1 core (B) twisted Polyester/Aluminium tape 1 core (C) + 3 cores (A) twisted PTFE tape ∅ = 5.55 mm nominal AWG 38 tin plated copper helicoidal screen. Polyurethane ∅ = 3.55 ±.15mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 50 - Microcables for patient monitoring (invasive applications) 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 51 - Filotex STUDY 123546 2 channels 36 AWG coax cable ® Medical cable for patient monitoring Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics PRODUCT REFERENCES FILOTEX Ref : ET 123 546 CONSTRUCTION Multi coax 95pF/m Core A : AWG 36 silver plated alloy wire. FEP insulation ∅ = .32 ± .03mm AWG 44 silver plated copper Helicoidal screen ∅ =.42mm nominal FEP jacket ∅ = .52 ± .03mm 2 Cores (A) + 2 cores (B) twisted ∅ = 1.02 mm nominal • ‚ ƒ AWG 44 tin plated copper helicoidal screen ∅ = 1.12mm nominal r Very flexible cable with an extremely good mechanical behaviour r Withstands miscellaneous sterilisation processes Applications r Ultrasound cable assemblies Electrical performancess r Characteristic impedance : 50 nominal r Linear capacitance : 95 ± 10 pF/m (at 95%) (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85 °C (100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter 3 2 1 Superpolyamide ∅ = 1.5 ± 1 mm This cable is not round. 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 52 - Microcables for ECG 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 53 - Filotex® STUDY 022595 ECG cable Medical ECG cable Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics PRODUCT REFERENCES r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r ECG cable assemblies. FILOTEX Ref : ET 022 595 Electrical performances r Continuous operating voltage : 250 V eff. Thermal performances r CONSTRUCTION Low noise cable Operating temperature : - 30°C to + 85 °C (100 °C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter • 24 x .05 mm stranded copper ∅ = .28 mm nominal ‚ Polyethylene insulation ∅ = .70 ± .05mm ƒ Semi-conductive layer ∅ = .73mm nominal „ .07 mm copper braid ∅ = 1mm nominal … PVC jacket ∅ = 1.4mm nominal. 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 54 - Temporary myocard pacing wire 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 55 - Passing on or copying of the document, use or communicate of its conte nt is not permitted without prior written authorization. Information subject to change without notice. Filotex STUDY 060517 ® Temporary myocard pacing wire Characteristics PRODUCT REFERENCES r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes FILOTEX Ref : ET 060 517 Electrical performances CONSTRUCTION • 19 x 0.06 stranded stainless steel 316L ‚ PE insulation ∅ = .65 ± .03mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r DC resistance : ≤ 16 Ω/m r Insulation resistance : ≥ 100 MΩ.km r Dielectric strength : ≥ 1500 V DC Thermal performances r Operating temperature : - 50°C to + 200 °C Mechanical performances r Minimum bending radius : 5 x Overall diameter . r Pull-off force : 5 N to 15 N Issue 1 - November 2000 - 56 - Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Filotex STUDY 132070 ® Temporary myocard pacing wire Characteristics PRODUCT REFERENCES r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes FILOTEX Ref : ET 132 070 Electrical performances CONSTRUCTION • 19 x 0.044 stranded stainless steel 316L ∅ = .22 ± .02mm ‚ PE insulation ∅ = .48 ± .02mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 r DC resistance : ≤ 30 Ω/m r Insulation resistance : ≥ 100 MΩ.km r Dielectric strength : ≥ 1500 V DC Thermal performances r Operating temperature : - 50°C to + 200 °C Mechanical performances r Minimum bending radius : 5 x Overall diameter . r Pull-off force : 5 N to 15 N Issue 1 - November 2000 - 57 - Filotex STUDY 132524 ® Temporary myocard pacing wire Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice. Characteristics PRODUCT REFERENCES FILOTEX Ref : ET 132 524 CONSTRUCTION • ‚ 19 x .044 mm stranded stainless steel 316L ∅ = .22 ± .02 mm r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Electrical performances r DC resistance of inner conductor : ≤ 50 Ω/m r DC resistance of outer conductor : ≤ 30 Ω/m r Insulation resistance of insulation : ≥ 100 MΩ.km r Insulation resistance of jacket : ≥ 100 MΩ.km r Dielectric strength : ≥ 1500 V DC Thermal performances r Operating temperature : - 30°C to + 75°C Mechanical performances r Minimum bending radius : 5 x Overall diameter Polyethylene insulation ∅ = .40 ± .02 mm ƒ 0.044 mm stainless steel 316L helicoidal screen min. coverage 90 % ∅ = .49 ± .02 mm „ Polyethylene jacket ∅ = .75 ± .05mm 140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70 Issue 1 - November 2000 - 58 -