microcables

advertisement
MICROCABLES
A complete vision of your
connectivity needs
Catalogue
ELECTRONIC
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Introduction
Filotex®
Nexans’s line of microcables is designed towards
the increasing requirements of electronics
applications for miniaturization, reliability,
performance, flexibility, higher density and EMI
protection.
From Medical to Instrumentation, Computers
to Automated Test Equipment, Nexans offers
solutions
for the most demanding electronics applications.
From 32 to 46 AWG, using high strength alloys and
extruded fluorine resins insulation, in flat or round
constructions, our development and design engineers
are at your disposal to provide their experience in
tailoring any of our products to meet your precise
requirements.
Application
ü Electronics:
- cables for instrumentation and test equipment
applications (rack bus, positioning sensor, logic
analysers,…);
- cables for internal equipment or device-to-device
connections.
ü Computer and audio/video appliances (CD ROMto-Laptop connection, LCD panels protection, DVD
connections,...).
ü Ultrasound (external or internal applications for
OB/Gyn, cardiology, veterinary, imaging
applications,…).
ü CCD cameras applications (CCD cameras for
medical, industrial, endoscopy and videosurveillance applications).
ü Other medical: Cardiac monitoring, pace makers,
ECG/EKG,…
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
-2-
Filotex®
ELECTRONIC
Advantages
ü Wide range of conductors and dielectric materials;
ü Unique patented extrusion technology for low
capacitance cables;
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
ü Ultra-flexible cables;
ü High speed transmission cable;
ü Space and weight saving;
ü High electrical performances (ε r up to 1.5)
ü Various styles available;
ü Good physical properties (different jacket material
for mechanical, chemical and climatic requirements).
Construction
Single wires or coaxial cables assembled in a variety
of constructions. Screened or unscreened wires
available.
Nexans designs round cable consisting of up to 528
elements and featuring an extremely small overall
diameter of 13.0 mm/0.51”.
The microcables product line includes coaxial cables
with an OD as small as 0.19mm/.007”.
Hook-up wires
ü Singlecore unscreened from AWG 46 to AWG 32
ü Singlecore screened and jacketed
from AWG 46 to AWG 32
Multicore and coaxial cables
ü From 2 to 528 conductors
ü From AWG 46 to AWG 32 inner conductor
ü Unscreened and jacketed or screened
jacketed
and
Composite cables
Assembly of quads, pairs, coaxial…
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
-3-
Filotex®
ELECTRONIC
Technology
Inner conductor: silver plated alloy, stainless steel, silver
plated copper (stranded or not)
Insulation: FEP, PFA, PE (plain or special melt extrusion)
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Assembly: PTFE tape
Drain wire*: silver plated alloy, silver plated copper
Mechanical support*: aramid strength member in option
Elect. Protection: polyester/aluminium tape, silver plated
copper or alloy screen, tin plated copper screen or
stainless steel screen
Jacket: FEP, PFA, PVC, PUR, PE, TPE, PA
* Optional
Main
characteristics
ü Impedance : 50 Ω to 130 Ω
ü Capacitance : 27 pF/m to 110 pF/m (8 pF/ft to 33pF/ft)
ü Operating voltage : from 24 V to 250 V
ü Operating temperature : from – 60°C to +200°C
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
-4-
Filotex®
ELECTRONIC
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Summary
Part 1
Microcables for all markets: single coaxials
- Normal capacitance: 95pF/m
- Low capacitance: 55pF/m
Part 2
Microcables for electronic application
Page 16
Part 3
Microcables for computer application
Page 20
Part 4
Microcables for ultrasound
Page 23
Part 5
Microcables for CCD cameras applications
- Microcables for Endoscopy
- Microcables for Dental application
Page 34
Page 35
Page 42
Part 6
Microcables for other medical applications
- Microcables for catheter
- Microcables for patient monitoring (invasive
applications)
- Microcables for ECG
- Temporary myocard pacing wire
Page 47
Page 48
Page 51
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Page 6
Page 7
Page 14
Page 53
Page 55
Issue 1 - November 2000
-5-
Part 1
Microcables for
all markets:
single coaxials
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
-6-
Normal capacitance
95pF/m
All cables are also available in
solid conductor version.
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
-7-
Filotex
STUDY 123836
32 AWG coax cable
®
Micro coaxial cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 123 836
Electrical performances
CONSTRUCTION
Multi coax 95 pF/m
•
AWG 32 stranded silver
plated alloy.
‚
FEP insulation
∅ = .65 ±.02mm
ƒ
44 AWG silver plated copper
Helicoidal screen
∅ = .75mm nominal
„
FEP jacket
∅ = .91 ± .03mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance
: 50 Ω nominal
r
Linear capacitance
: 95 ± 10 pF/m (29pF/ft)
r
Continuous operating voltage
: 24 V eff.
r
Test voltage between core and screen
:350 V DC 1 mn
Thermal performances
r
Operating temperature
: - 50°C to + 200 °C
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter .
Standard colours
r
Dielectric : Black – Brown - Red - Orange - Yellow - Green - Blue Violet - Grey - White – Translucide
r
Jacket : White
¬
-
®
¯
Issue 1 - November 2000
-8-
Filotex
STUDY 132474
34 AWG coax cable
®
Micro coaxial cable
Characteristics
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
r
Very flexible cable with an extremely good mechanical
behaviour.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 132 474
Electrical performances
CONSTRUCTION
Multi coax 95 pF/m
•
34 AWG(7 x .06 mm)
stranded silver plated copper
‚
PFA insulation
∅ = .53 ± .02mm
ƒ
44 AWG silver plated copper
braid Helicoidal screen
∅ = .75mm nominal
„
PFA jacket
∅ = .85 ± .03 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance
: 50 Ω nominal
r
Linear capacitance
: 95 ± 10 pF/m (29pF/ft)
r
Continuous operating voltage
: 24 V eff.
r
Test voltage between core and screen
:350 V DC 1 mn
Thermal performances
r
Operating temperature
: - 50°C to + 200°C
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter .
Standard colours
r
Dielectric : Green
r
Jacket : Black - Brown - Red - Orange – Yellow - Green - Blue Violet - Grey - White – Translucide
Issue 1 - November 2000
-9-
Filotex
STUDY 124954
36 AWG coax cable
®
Micro coaxial cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
r
Ultrasound cable assemblies.
Electrical performances
PRODUCT REFERENCES
FILOTEX Ref : ET 124 954
r
Characteristic impedance : 50 Ω nominal
r
Linear capacitance : 95 ± 10 pF/m (29pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
CONSTRUCTION
Multi coax 95 Pf/M
•
AWG 36 stranded silver
plated copper.
‚
FEP insulation
∅ = .44 ± 02mm
ƒ
44 AWG silver plated copper
Helicoidal screen
∅ = .54mm nominal
„
Operating temperature : - 50°C to + 200 °C
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter .
Standard colours
r
Dielectric : Red or Green
r
Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue Violet - Grey - White - Translucide
¬
-
®
¯
FEP jacket
∅ = .63 ± .03 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 10 -
Filotex
STUDY 122882
38 AWG coax cable
®
Micro coaxial cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
PRODUCT REFERENCES
FILOTEX Ref : ET 122 882
CONSTRUCTION
Multi coax 95pF/m
•
AWG 38 stranded silver
plated alloy
‚
FEP insulation
∅ = .34 ± .02mm
ƒ
44 AWG silver plated copper
Helicoidal screen
∅ = 44mm nominal
„
FEP jacket
∅ = .53 ± .02mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Very flexible cable with an extremely good mechanical behaviour
r
Withstands miscellaneous sterilisation processes
Applications
r Ultrasound cable assemblies
Electrical performances
r
Characteristic impedance
: 50 Ω nominal
r
Linear capacitance
: 95 ± 10 pF/m (29pF/ft)
r
Continuous operating voltage
: 24 V eff.
r
Test voltage between core and screen
: 350 V DC 1 mn
Thermal performances
r
Operating temperature
: - 50°C to + 200 °C
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter .
Standard colors
r
Dielectric : Red or Green
r
Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue Violet - Gray - White - Translucide
¬
-
®
¯
Issue 1 - November 2000
- 11 -
Filotex
STUDY 132469
40 AWG coax cable
®
Micro coaxial cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 132 469
Electrical performances
CONSTRUCTION
Multi coax 95 pF/m
•
AWG 40 silver plated alloy
135 wire
‚
PFA insulation.
∅ = .23 ± 02mm
ƒ
48 AWG silver plated copper
Helicoidal screen
∅ = .29mm nominal
„
PFA jacket
∅ = .36 ± .03 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance
: 50 Ω nominal
r
Linear capacitance
: 95 ± 10 pF/m (29pF/ft)
r
Continuous operating voltage
: 24 V eff.
r
Test voltage between core and screen
:350 V DC 1 mn
Thermal performances
r
Operating temperature
: - 50°C to + 200°C
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter .
Standard colours
r
Dielectric : Green
r
Jacket : Black - Brown - Red - Orange – Yellow - Green - Blue Violet - Grey - White – Translucide
¬
-
®
¯
Issue 1 - November 2000
- 12 -
Filotex
STUDY 132358
42 AWG coax cable
®
Micro coaxial cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 132 358
Electrical performances
CONSTRUCTION
Multi coax 95 pF/m
r
Characteristic impedance
: 50 Ω nominal
r
Linear capacitance
: 95 ± 10 pF/m (29pF/ft)
r
Continuous operating voltage
: 24 V eff.
r
Test voltage between core and screen
:350 V DC 1 mn
Thermal performances
r
Operating temperature
Mechanical performances
•
AWG 42 stranded silver
plated alloy
r
‚
PFA insulation ∅ = .21mm
Standard colours
ƒ
48 AWG silver plated copper
Helicoidal screen
∅ = .27mm nominal
„
FEP jacket
∅ = .35 ± .03 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
: - 50°C to + 200°C
Minimum bending radius
: 5 x Overall diameter .
r
Dielectric : Green
r
Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue Violet - Grey - White - Translucide
¬
-
®
¯
Issue 1 - November 2000
- 13 -
Low capacitance
55pF/m
All cables are also available in
solid conductor version.
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 14 -
Filotex
STUDY 132475
40 AWG coax cable
®
Micro coaxial cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 132 475
Electrical performances
CONSTRUCTION
Multi coax 55 pF/m
•
AWG 40 silver plated alloy
135 wire
‚
PFA “SE” insulation
∅ = .36 ± .02mm
ƒ
48 AWG silver plated copper
Helicoidal screen
∅ = .42mm nominal
„
PFA jacket
∅ = .47 ± .03 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance
: 80 Ω nominal
r
Linear capacitance
: 55 ± 5 pF/m (at 95%)(17pF/ft)
r
Continuous operating voltage
: 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
r
Max DC resistance
: 1.2 Ω/ft
Thermal performances
r
Operating temperature
: - 50°C to + 200°C
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter .
Standard colours
r
Dielectric : Red
r
Jacket : Black - Brown - Red - Orange – Yellow - Green – Blue Violet – Grey - White – Translucide
¬
-
®
¯
Issue 1 - November 2000
- 15 -
Part 2
Microcables for
electronic application
Linear capacitance :
ET 132211
27pF/m
ET 132084 33pF/m
ET 124810 55pF/m
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 16 -
Filotex
STUDY 132211
41 AWG coax cable
®
Cable for electronic application
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
PRODUCT REFERENCES
FILOTEX Ref : ET 132 211
CONSTRUCTION
Coax 130 Ω
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Electrical performances
r
Characteristic impedance
: 130 ± 10 Ω
r
Max linear capacitance
: 27 pF/m (8 pF/ft)
r
DC resistance
: 130 ± 8 Ω/m
r
Continuous operating voltage
: 30 V eff.
r
Test voltage between core and screen
:350 V DC 1 mn
Thermal performances
r
Operating temperature
Mechanical performances
•
AWG 41 constantan
r
‚
FEP “SE” insulation
∅ = .95 ±.05mm
Standard colours
ƒ
44 AWG silver plated copper
Helicoidal screen
∅ = 1.05mm nominal
„
PVC jacket
∅ = 1.40mm max
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
: - 50°C to + 80°C
Minimum bending radius
r
Dielectric : Yellow
r
Jacket : Flint Grey
¬
-
: 5 x Overall diameter .
®
¯
Issue 1 - November 2000
- 17 -
Filotex
STUDY 132084
41 AWG coax cable
®
Cable for electronic application
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
PRODUCT REFERENCES
FILOTEX Ref : ET 132 084
CONSTRUCTION
Coax 130 Ω
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Electrical performances
r
Characteristic impedance
: 130 ± 10 Ω
r
Linear capacitance
: 33 ± 3 pF/m (10pF/ft)
r
DC resistance
: 130 ± 8 Ω/m
r
Continuous operating voltage
: 30 V eff.
r
Test voltage between core and screen
:350 V DC 1 mn
Thermal performances
r
Operating temperature
Mechanical performances
•
AWG 41constantan
r
‚
FEP “SE” insulation
∅ = .70 ±.03mm
Standard colours
ƒ
44 AWG silver plated copper
Helicoidal screen
∅ = .80mm nominal
„
PVC jacket
∅ = 1.1 ± .05mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
: - 50°C to + 80°C
Minimum bending radius
r
Dielectric : Red
r
Jacket :Flint Grey
¬
-
: 5 x Overall diameter .
®
¯
Issue 1 - November 2000
- 18 -
Filotex
STUDY 124810
4 channels 38 AWG coax cable
®
Cable for electronic application
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Cable for displacement sensor.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 124 810
Electrical performances
r
Characteristic impedance : 80 Ω nominal
r
Linear capacitance : 55 ± 5 pF/m (at 95%).(17pF/ft)
r
Current capacity : > 250 mA
r
Continuous operating voltage : 250 V DC.
Thermal performances
CONSTRUCTION
r
Multi coax 55 pF/m
Operating temperature : - 20°C to + 75 °C
Mechanical performances
Core A :
AWG 38 stranded silver
plated alloy.
FEP
insulation
∅ = .51 ± 02mm
AWG 48 silver plated copper
Helicoidal screen
∅ = .57mm nominal
FEP jacket ∅ = .62 ± 02mm
4 Cores A twisted ∅ =
1.5mm
•
‚
PTFE
∅ = 1.55mm nominal
ƒ
AWG 41 tin plated copper
braid 90 % coverage
∅ = 1.8mm nominal
„
Medical P.V.C
∅ = 2.8 ± .15mm
r
Minimum bending radius : 5 x Overall diameter
tape
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 19 -
Part 3
Microcables for
computer application
Linear capacitance :
ET 132433 55 pF/m
ET 132167
100 pF/m
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 20 -
Filotex
STUDY 132433
49 channels 42 AWG coax cable
+ 8 x 28 AWG wires
®
Cable for computer application (input/output)
Characteristics
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
r
Very flexible cable with an extremely good mechanical behaviour.
Electrical performances
PRODUCT REFERENCES
FILOTEX Ref : ET 132 433
CONSTRUCTION
Multi coax 55 pF/m
• Core A :
AWG 42 (1 x 0.064 mm) silver
plated Alloy.
PFA " SE " insulation ∅ = .26 ±
.02mm
AWG 48 silver plated copper
Helicoidal screen ∅ = .32 mm
nominal
PFA jacket ∅ = .36 ± .02mm
‚ Core B :
AWG 28 (7 x 0.13 mm)
stranded tin plated copper.
PFA insulation ∅ = .59 ± .03 mm
ƒ Core C :
8 Cores A twisted ∅ = 1.1 mm
„ Core D :
9 Cores A twisted ∅ = 1.3 mm
5 cores (C) + 1 cores (D) + 8 cores
(B) twisted ∅ = 4.0 mm nominal
… PTFE tape ∅ = 4.06 mm nominal.
† AWG 40 tin plated copper braid
85 % coverage
∅ = 4.40 mm nominal
‡ PVC jacket ∅ = 5.9 ± .2 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance cores A : 80 Ω nominal
r
Linear capacitance cores A : 55 ± 5 pF/m (at 95%).(17 pF/ft)
r
DC resistance cores A : <= 7.8 Ω/m (2.5 Ω/ft)
r
Continuous operating voltage cores A : 24 V eff.
r
Continuous operating voltage cores B : 250 V DC
r
DC resistance cores B : <= .25 Ω/m (.076 Ω/ft)
r
Test voltage between core and screen : 350 V DC 1 mn
r
Insulation resistance : > 1000 MΩ.km
Thermal performances
r
Operating temperature : - 30°C to + 85°C (100°C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 21 -
C
Filotex
STUDY 132167
49 channels 42 AWG coax cable
+ 8 x 28 AWG wires
®
Cable for computer application (input/output)
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Electrical performances
PRODUCT REFERENCES
FILOTEX Ref : ET 132 167
CONSTRUCTION
Multi coax 100 pF/m
• Core A :
AWG 42 (1 x 0.064 mm) silver
plated Copper.
FEP insulation ∅ = .19 ± .02mm
AWG 48 tin plated copper
Helicoidal screen
∅ = .25mm nominal
FEP jacket ∅ = .30 ± .02mm
‚ Core B :
AWG 28 (7 x 0.13 mm)
stranded tin plated copper.
FEP insulation ∅ = .59 ± .03mm
ƒ Core C :
8 Cores A twisted ∅ = 0.9mm
„ Core D :
9 Cores A twisted ∅ = 1.1mm
5 cores (C) + 1 cores (D) + 8
cores B twisted
∅ = 3.75mm nominal
… PTFE tape ∅ = 3.8mm nominal.
† AWG 40 tin plated copper braid
85 % coverage
∅ = 4.15mm nominal
‡ PVC jacket ∅ = 5.5 ± .2mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance cores A : 50 Ω nominal
r
Linear capacitance cores A : 100 ± 10 pF/m (at 95%).(30.5pF/ft)
r
DC resistance cores A : <= 7.8 Ω/m
r
Continuous operating voltage cores A : 24 V eff.
r
Continuous operating voltage cores B : 250 V DC
r
DC resistance cores B : <= .25 Ω/m
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
Operating temperature : - 30°C to + 85°C (100°C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 22 -
Part 4
Microcables for
Ultrasound
Applications :
q Veterinary application
(mechanical probes)
q Transvaginal application
q Endocavity application
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 23 -
Filotex
STUDY 124311
11 channels 34 AWG coax
+ 8 x 26 AWG wires
®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
r
Ultrasound cable assemblies.
Electrical performances
PRODUCT REFERENCES
FILOTEX Ref : ET 124 311
r
Characteristic impedance core (A) : 50 nominal
r
Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
CONSTRUCTION
Ultra sound cable
•
‚
ƒ
„
…
†
‡
Core A :
AWG 34 stranded silver
plated alloy.
PTFE insulation
∅ = .52 ±.02mm
AWG 43 silver plated copper
braid
FEP jacket ∅ = 1.02 ±.05 mm
Core B :
AWG 26 stranded tin plated
copper.
PVC insulation
∅ = .90 ±.10mm
Fillers
7 cores (A) + 1 filler twisted
AWG 40 tin plated copper
helicoidal screen 90 %
coverage 4 cores (A) + 8
cores (B) + fillers twisted
around
PTFE tape
AWG 40 tin plated copper
braid 95 % coverage
Medical PVC ∅ = 7.45 ±3mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
q
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 24 -
Filotex
STUDY 124973
26 channels 36 AWG coax cable
+ 20 wires 30 AWG
®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 124 973
Electrical performances
CONSTRUCTION
Multi coax 95 pF/m
•
‚
ƒ
„
…
†
‡
ˆ
‰
Core A :
AWG 36 stranded silver
plated copper.
FEP insulation
∅ = .44 ±.03mm
AWG 44 silver plated copper
Helicoidal screen
∅ = .54mm nominal
FEP jacket ∅ = .63 ± .03 mm
Core B:
AWG 30 stranded silver
plated copper.
FEP insulation ∅ = .5 ± 1mm
Core C: 3 cores A twisted
Core D: 4 cores B twisted
Core E: 3 cores B twisted
Core F:
2 cores A + 1 core B twisted
8 Cores (C) + 4 cores D + 1
core E + 1 core F twisted
∅ = 5.2 mm nominal
PTFE tape
∅ = 5.25 mm nominal.
AWG 40 tin plated copper
braid 85 % coverage
∅ = 5.6mm nominal
Medical PVC ∅ = 7.0 ± .3mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance core (A) : 50 nominal
r
Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
r
DC resistance core (A) : 1.5 Ω/m
r
DC resistance core (B) : .4 Ω/m
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 25 -
STUDY 124733
33 channels 40 AWG coax
+ 12 x 36 AWG wires
Filotex®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
PRODUCT REFERENCES
FILOTEX Ref : ET 124 733
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
r
CONSTRUCTION
Ultrasound cable
• Core A :
AWG 40 stranded silver plated
alloy.
FEP insulation ∅ = .25 ± .02 mm
AWG 48 silver plated copper
Helicoidal screen
∅ = .31 mm nominal
FEP jacket ∅ = .39 ± .02 mm
‚ Core B :
AWG 36 stranded silver plated.
FEP insulation ∅ = .40 ± .02mm
ƒ Core (C)
7 cores (A) twisted
„ Core (D)
6 cores (B) +Cotton filler twisted
… Core (E)
5 cores (A) +Cotton filler twisted
4 Cores (C) + 2 cores (D) + 1
core (E) twisted ∅ = 3.50 mm
nominal
† PTFE tape
∅ = 3.7 mm nominal.
Ultrasound cable assemblies.
Electrical performances
r
Characteristic impedance core (A) : 50 Ω nominal
r
Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
‡ AWG 44 tin plated copper braid
85 % coverage
∅ = 3.9 mm nominal
ˆ Medical PVC ∅ = 4.9 ± .1mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 26 -
STUDY 123992
66 channels 38 AWG coax cable
Filotex®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 123 992
Electrical performances
CONSTRUCTION
Multi coax 95 pF/m
• Core A :
AWG 38 stranded silver
plated alloy.
FEP insulation
∅ = .34 ±.02mm
AWG 44 silver plated copper
Helicoidal screen
∅ = .44mm nominal
FEP jacket ∅ = .53 ± .02mm
‚ Core B :
8 Cores A twisted ∅ =
1.6mm
ƒ Core C :
2 Cores A twisted
∅ = 1.05mm
8 cores (B) + 1 cores (C)
twisted ∅ = 5.3mm nominal
„ PTFE tape
∅ = 5.35mm nominal.
… AWG 40 tin plated copper
braid.85 % coverage
∅ = 5.7mm nominal
† Medical P.V.C
∅ = 8 ± .2mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance
: 50 nominal
r
Linear capacitance
: 95 ± 10 pF/m (at 95%).(29pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
Operating temperature
: - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter
Issue 1 - November 2000
- 27 -
Filotex
STUDY 124480
84 channels 38 AWG coax cable
®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
PRODUCT REFERENCES
r
Ultrasound cable assemblies.
Electrical performances
FILOTEX Ref : ET 124 480
r
Characteristic impedance : 50 nominal
r
Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
CONSTRUCTION
•
‚
ƒ
„
…
†
Multi coax 95 pF/m
Core A :
AWG 38 stranded silver
plated alloy.
FEP insulation
∅ = .34 ±.02mm
AWG 44 silver plated copper
Helicoidal screen
∅ = 44mm nominal
FEP jacket ∅ = .53 ± .02mm
Core B :
8 Cores A twisted
∅ = 1.6mm
Core C :
2 Cores A twisted
∅ = 1.05mm
10 cores (B) + 2 cores (C)
twisted ∅ = 6.0mm nominal
PTFE tape
∅ = 6.05 mm nominal.
AWG 40 tin plated copper
braid 85 % coverage
∅ = 6.4mm nominal
Medical P.V.C
∅ = 8.0 ±.2mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
r
Flex life test : Standard test in accordance with drawing 250,000
cycles minimum
Mover rollers ∅ 80 mm
Moving range : 550 mm
Cable length
Speed
Test weight (M)
: 1600 mm
: .22 m/s (8 cycles/mn)
: 3000 g
Issue 1 - November 2000
- 28 -
Filotex
STUDY 124499
132 channels 38 AWG coax cable
®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 124 499
Electrical performances
CONSTRUCTION
Multi coax 95 pF/m
Core A :
AWG 38 silver plated copper
wire.
FEP insulation
∅ = .30 ±.02mm
AWG 48 silver plated copper
Helicoidal screen
∅ = .36mm nominal
FEP jacket ∅ = .46 ± .02mm
‚ Core B :
4 Cores A twisted ∅ =
1.1mm
ƒ Core C :
8 Cores A twisted ∅ =
1.4mm
1 cores (B) + 16 cores (C)
twisted ∅ = 6.5mm nominal
„ PTFE tape
∅ = 6.6mm nominal.
… AWG 41 tin plated copper
braid 85 % coverage
∅ = 7.0mm nominal
•
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance : 50 Ω nominal
r
Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
Operating temperature : - 30°C to + 85°C (100°C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 29 -
Filotex
STUDY 132029
132 channels 40 AWG coax cable
®
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Medical Ultrasound cable
Characteristics
r Very flexible cable with an extremely good mechanical
behaviour.
r Withstands miscellaneous sterilisation processes.
Applications
PRODUCT REFERENCES
r
Ultrasound cable assemblies.
r
FILOTEX Ref : ET 132 029
Electrical performances
r
Characteristic impedance : 80 Ω nominal
r
Linear capacitance : 55 ± 5 pF/m (at 95%).(17pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V AC 1 mn
r
Max DC resistance of centre conductor : 1.2 Ω/ft
CONSTRUCTION
Multi coax 55pF/m
•
‚
ƒ
„
…
†
Core A :
AWG 40 stranded silver
plated alloy PD 135.
FEP « SE » insulation
∅ =.34 ± .03 mm
AWG 48 silver plated copper
Helicoidal screen
∅ =.40mm nominal
FEP jacket ∅ = .46 ± .03mm
Core B :
4 Cores A + Kevlar member
tensile strength 50 kgF
twisted ∅ = 1.15mm
Core C :
8 Cores A twisted
∅ = 1.5mm
1 core (B) + 16 cores C
twisted ∅ =6.3mm nominal
PTFE tape
∅ = 6.35 mm nominal.
AWG 40 silver plated alloy
braid 85 % coverage
∅ = 6.7mm nominal
Medical P.V.C
∅ = 8.5 ±.25mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 30 -
Filotex
STUDY 124590
132 channels 42 AWG coax cable
®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 124 590
Electrical performances
CONSTRUCTION
Multicoax 95 pF/m
• Core A :
AWG 42 silver plated copper wire.
FEP insulation ∅ = .20 ± .02 mm
AWG 48 silver plated copper
Helicoidal screen
∅ = .26 mm nominal
FEP jacket ∅ = .34 ± .02 mm
r
Characteristic impedance : 50 Ω nominal
r
Linear capacitance : 95 ± 10 pF/m (at 95%).(29 pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
‚ Core B :
4 Cores A twisted ∅ = .8 mm
ƒ Core C :
8 Cores A twisted ∅ = 1 mm
1 cores (B) + 16 cores (C) twisted
∅ = 4.7 mm nominal
„ PTFE tape
∅ = 4.8 mm nominal.
… AWG 40 silver plated alloy braid
85 % coverage
∅ = 5.2 mm nominal
† Medical P.V.C
∅ = 7.2 ± .3 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 31 -
Filotex
STUDY 124541
192 + 4 channels 40 AWG coax cable
®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not p ermitted without prior written authorization. Information subject to change without notice.
Characteristics
r Very flexible cable with an extremely good mechanical
behaviour.
r Withstands miscellaneous sterilisation processes.
Applications
r
PRODUCT REFERENCES
FILOTEX Ref : ET 124 541
CONSTRUCTION
Multi coax 55pF/m
•
‚
ƒ
„
…
†
Core A :
AWG 40 stranded 7x.03mm
silver plated alloy PD 135.
FEP « SE » insulation
∅ = .34 ± .02 mm
AWG 48 silver plated copper
Helicoidal screen
∅ =.40mm nominal
FEP jacket ∅ = .46 ± .02mm
Core B :
16 Cores A twisted
∅ = 2.1mm
Core C :
4 Cores A twisted
∅ =.95mm
12 cores (B) + 1 core C
twisted ∅ =7.7mm nominal
PTFE tape
∅ = 7.75mm nominal.
AWG 40 tin plated copper
braid 85 % coverage
∅ = 8.1mm nominal
Medical PVC
∅ = 9.6 ±.3mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Ultrasound cable assemblies.
Electrical performances
r
Characteristic impedance : 80 Ω nominal
r
Linear capacitance : 18 ± 2 pF/ft (at 95%)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 500 V AC 1 mn
r
Max DC resistance of centre conductor : 1.2 Ω/ft
r
Max DC resistance of coax shield : 15 Ω/ft
r
Insulation resistance : > 10 MΩ
r
Crosstalk coax to coax , 1 ~ 10 Mhz in 96 inches long cable will all
ends terminated in 80 Ω : < 55 dB
r
One way signal loss (1 ~ 10 Mhz) : < 0.10 dB/ft
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 32 -
Filotex
STUDY 132081
256 + 8 channels 40 AWG coax cable
®
Medical Ultrasound cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 132 081
Electrical performances
CONSTRUCTION
Multicoax 95pF/m
• Core A :
AWG 40 stranded silver plated
alloy.
FEP insulation
∅ = .24 ± .02 mm
AWG 48 silver plated copper
Helicoidal screen
∅ = .3 mm nominal
FEP jacket ∅ = .39 ± .02 mm
r
Characteristic impedance : 50 Ω nominal
r
Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
r
DC resistance : <= 1.2 Ω/ft
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
‚ Core B :
16 Cores A twisted ∅ = 1.9 mm
ƒ Core C :
8 Cores A twisted ∅ = 1.2 mm
16 cores (B) + 1 core (C) twisted
∅ = 7.6 mm nominal
„ PTFE tape
∅ = 7.65 mm nominal.
… Medical P.V.C
∅ = 9.6 ± .30 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 33 -
Part 5
Microcables for
CCD cameras applications
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 34 -
Microcables for
Endoscopy
Available models
3.5 mm
ET 123602
5 mm
ET 132468
ET 123540
ET 124991
ET 124692
7 mm
ET 132028
Optional
UL style approval : UL20379
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 35 -
Filotex
STUDY 123602
9 channels 38 AWG coax
+ 5 x 38 AWG wires
®
Medical Video Endoscopy cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subje ct to change without notice.
Characteristics
PRODUCT REFERENCES
FILOTEX Ref : ET 123 602
CONSTRUCTION
Video camera Cable
•
‚
ƒ
„
…
†
Core A :
AWG 38 stranded silver
plated alloy.
FEP insulation
∅ = .34 ±.02mm
AWG 44 silver plated copper
Helicoidal screen
∅ = .44mm nominal
FEP jacket ∅ = .53 ± .02 mm
Core B :
AWG 38 stranded silver
plated alloy.
FEP insulation
∅ = .34 ±.05mm
Fillers
9 Cores (A) + 5 cores (B) +
Fillers twisted
∅ = 2.05 mm nominal
PTFE tape
∅ = 2.07 mm nominal.
AWG 40 tin plated copper
braid 85 % coverage
∅ = 2.5mm nominal
Medical PVC ∅ = 3.45 ±.1mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Very flexible cable with an extremely good mechanical behaviour
r
Withstands miscellaneous sterilisation processes
Applications
r Video Endoscopy cable assemblies
Electrical performances
r
Characteristic impedance (core A)
: 50 nominal
r
Linear capacitance (core A) : 95 ± 10 pF/m (at 95%) (29pF/ft)
r
Continuous operating voltage
: 24 V eff.
r
Test voltage between core and screen
: 350 V DC 1 mn
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100°C at peak)
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter .
Issue 1 - November 2000
- 36 -
Filotex
STUDY 132468
1 channel 30 AWG coax
+ 11 x 28 AWG wires
®
Medical Video Endoscopy cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Video endoscopy cable assemblies
PRODUCT REFERENCES
r
FILOTEX Ref : ET 132 468
Electrical performances
r
Characteristic impedance core (B and D) : 50 Ω nominal
r
Linear capacitance core (B and D) : 110±10 pF/m (at 95%)
(33 pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Video camera Cable
•
‚
ƒ
„
…
†
Core A :
AWG 30 (19 x 42 AWG)
stranded silver plated alloy.
FEP insulation
∅ = .82 ±.05mm
AWG 40 silver plated
copper braid
∅ = 1.20mm nominal
FEP jacket ∅ = 1.55 ± .05mm
Core B:
AWG 28 (19 x 40 AWG)
stranded silver plated copper.
FEP insulation
∅ = .60 ±.05mm
1 Core (A) + 11 cores (B)
twisted
∅ = 2.75 mm nominal
PTFE tape.
∅ = 2.90 mm nominal
AWG 40 silver plated copper
spiral shield
∅ = 3.25 mm nominal
PTFE tape.
∅ = 3.4mm nominal
Medical PVC
∅ = 5.45 ±.2mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 37 -
Filotex
STUDY 123540
2 channels 34 AWG coax
+ 5 x 28 AWG wires
®
Medical Video Endoscopy cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
r
Very flexible cable with an extremely good mechanical behaviour.
Withstands miscellaneous sterilisation processes
Applications
PRODUCT REFERENCES
r
Video Endoscopy cable assemblies
FILOTEX Ref : ET 123 540
Electrical performances
CONSTRUCTION
Video camera Cable
•
‚
ƒ
„
…
Core A :
AWG 34 stranded silver
plated alloy.
PFA insulation
∅ = .53 ±.03mm
AWG 44 silver plated copper
Helicoidal screen
∅ = .63mm nominal
PFA jacket ∅ = .98 ± .05mm
Core B :
AWG 28 stranded tin plated
copper.
PVC insulation
∅ = 1.1 ± .05mm
2 core (A) + 5 cores (B)
twisted ∅ = 3.3 mm nominal
PTFE tape
∅ = 3.35 mm nominal
AWG 41 tin plated copper
braid 85% coverage
∅ = 3.7 mm nominal
Medical PVC ∅ = 5.0±15mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Linear capacitance core (A)
r
DC resistance (A)
Ω/100m nominal
: 100 pF/m nominal
: 95
Thermal performances
r
Operating temperature
: - 30°C to + 85°C
(100°C at peak)
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter .
Issue 1 - November 2000
- 38 -
Filotex
STUDY 124991
5 channels 30 AWG coax
+ 3 x 30 AWG wires
®
Medical video Endoscopy cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Medical cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 124 991
Electrical performances
r
Characteristic impedance core (A) : 50 nominal
r
Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
•
‚
ƒ
„
…
Core A :
AWG 30 stranded silver
plated copper.
FEP insulation
∅ = .80 ±.02mm
AWG 38 silver plated copper
helicoidal screen
∅ = 1.0 mm nominal
FEP jacket
∅ = 1.2 ± .03 mm
Core B:
AWG 30 stranded silver
plated copper.
PTFE insulation
∅ = .81 ± .05mm
5 Cores (A) + 3 cores (B)
twisted
∅ = 4.05 mm nominal
PTFE tape
AWG 40 tin plated copper
braid 85% coverage
∅ = 4.4mm nominal
Polyurethane
∅ = 5.7 ± .2mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 39 -
Filotex
STUDY 124692
9 channels 32 AWG coax
+ 3 x 26 AWG wires
®
Medical Video Endoscopy cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Video endoscopy cable assemblies
PRODUCT REFERENCES
r
FILOTEX Ref : ET 124 692
Electrical performances
CONSTRUCTION
Video camera Cable
•
‚
ƒ
„
…
Core A :
AWG 32 stranded silver
plated alloy.
FEP insulation
∅ = .65 ±.03mm
AWG 44 silver plated copper
Helicoidal screen
∅ = .75mm nominal
FEP jacket ∅ = .91 ± .05mm
Core B :
AWG 26 stranded tin plated
copper.
FEP insulation
∅ = .81 ±.05mm
9 Cores (A) + 3 cores (B)
twisted ∅ = 3.6mm nominal
PTFE tape
∅ = 3.65mm nominal.
AWG 40 tin plated copper
braid 85 % coverage
∅ = 4.1mm nominal
Medical PVC ∅ = 5.0 ± .2mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Characteristic impedance core (A) : 50 nominal
r
Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft)
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 40 -
STUDY 132028
3 channels 28 AWG coax
6 channels 32 AWG coax
+ 3 x 26 AWG wires
Filotex®
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Medical Video Endoscopy cable
Characteristics
q Very flexible cable with an extremly good mechanical behaviour.
q
PRODUCT REFERENCES
FILOTEX Ref : ET 132 028
CONSTRUCTION
Withstands miscellaneous sterilization processes.
Applications
q Video endoscopy cable assemblies.
Electrical performances
q Characteristic impedance core (A) : 50 nominal
q Linear capacitance core (A) : 80 pF/m nominal
q Characteristic impedance core (B) : 50 nominal
q Linear capacitance core (B) : 95 pF/m nominal
q Continuous operating voltage : 30 V eff.
q Test voltage between core and screen : 500 V AC 1 mn
Thermal performances
q Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Video Camera Cable
• Core A :
AWG 28 stranded silver plated alloy.
FEP insulation ∅ = 1.1 ± .05 mm
AWG 40 silver plated copper
Helicoidal screen ∅ = 1.26 mm
nominal
FEP jacket ∅ = 1.58 ± .05 mm
‚ Core B :
AWG 32 stranded silver plated alloy.
FEP insulation ∅ = .63 ± .05 mm
AWG 44 silver plated copper
Helicoidal screen ∅ = .73 mm
nominal
FEP jacket ∅ = .91 ± .05 mm
ƒ Core C :
AWG 26 stranded silver plated copper.
FEP insulation ∅ = .80 ± .05 mm
„ Cotton filler
Mechanical performances
q Minimum bending radius : 5 x Overall diameter
3 Cores (A) + 6 cores (B) + 3 cores (C)
twisted ∅ = 4.4 mm nominal
… PTFE tape ∅ = 4.45 mm nominal.
† AWG 40 tin plated copper braid
85 % coverage ∅ = 4.8 mm nominal
‡ Medical PVC ∅ = 6.8 ± .2 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 41 -
Microcables for
Dental application
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 42 -
STUDY 124844
1 channels 34 AWG coax
+ 8 x 34 AWG wires
+ 2 x 30 AWG wires
Filotex®
Dental cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Video endoscopy cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 124 844
Electrical performances
r
Linear capacitance core (A) : 100 pF/m nominal
r
DC resistance core (A) : 95
r
Ω /100m nominal
DC resistance core (B) : 33.7 Ω /100m nominal
DC resistance core (C) : 95 Ω /100m nominal
r
Test voltage between braid and outside : 4000 V AC 1 mn
r
CONSTRUCTION
Video camera Cable
• Core A : AWG 34
stranded silver plated alloy.
PFA insulation ∅ = .53 ±.03mm
AWG 44 silver plated copper
Helicoidal screen
nominal ∅ = .63mm
PFA jacket ∅ = .83 ± .05mm
‚ Core B : AWG 30
stranded silver plated alloy.
PFA insulation ∅ = .50 ± .05mm
ƒ Core C :
AWG 34 stranded silver plated
alloy. PFA insulation
∅ = .36 ±.05mm
1 core (A) + 2 cores (B) + 8
cores (C) twisted
∅ = 2.05mm nominal
„ 34 AWG silver plated alloy Drain
wire
… PTFE tape ∅ = 2.10 mm nominal
† AWG 40 silver plated alloy braid
85 % coverage
∅ = 2.60 mm nominal
‡ Medical PVC ∅ = 4.1 ± .15mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 43 -
STUDY 132331
2 channels 36AWG coax
+ 9 x 32 AWG wires
+ 10 x 32 AWG wires
Filotex®
Dental cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
PRODUCT REFERENCES
FILOTEX Ref : ET 132 331
CONSTRUCTION
Video camera Cable
•
‚
ƒ
„
…
†
‡
ˆ
‰
Core A :
AWG 36 stranded silver plated
alloy
PFA insulation
∅ = .52 ± .03mm
AWG 44 silver plated copper
Helicoidal screen
∅ =.62mm nominal
PFA jacket ∅ = .72 ± .05mm
Core B :
AWG 32 stranded silver plated
alloy PFA insulation
∅ = .42 ± .05mm
2 cores (A) + 9 cores (B) twisted ∅
= .2.3 nominal
PTFE tape ∅ 2.35 mm nominal.
AWG 40 silver plated copper
braid 85% coverage
∅ = 2.7mm nominal
2 Medical PTFE tapes
∅ =3.2 ± 3.2mm max
Optional fillers
10 cores (B) around
∅ = 4.05mm
PTFE tape ∅ = 4.1mm nominal
Medical PVC ∅ = 5.3 ± .2mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
Very flexible cable with an extremely good mechanical behaviour
r
Withstands miscellaneous sterilisation processes
Applications
r Video endoscopy cable assemblies
Electrical performances
r
Characteristic impedance
: 60 nominal
r
Linear capacitance
: 80pF/m nominal
r
Continuous operating voltage
: 24 V eff.
r
DC resistance core (A)
: 150 Ω/100m
r
DC resistance core (B)
: 600 Ω/100m
r
Test voltage between core and screen
: 350 V DC 1 mn
Thermal performances
r
Operating temperature
: - 30°C to + 85 °C (100°C at peak)
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter
9
8
7
6
5
4
3
2
1
Issue 1 - November 2000
- 44 -
STUDY 132116
2 x 36 AWG twisted pairs
+ 14 x 36 AWG wires
Filotex®
Dental cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Video endoscopy cable assemblies.
PRODUCT REFERENCES
r
FILOTEX Ref : ET 132 116
Electrical performances
•
‚
ƒ
„
…
†
‡
ˆ
r
Linear capacitance core (C) : 63 pF/m nominal
r
Linear capacitance between 2 cores (B) : 43 pF/m nominal
r
Linear capacitance between cores (B) and braid : 80 pF/mnominal
r
All capitance must be verify on a sample
r
DC resistance core (A) and (B) : 2.07
CONSTRUCTION
r
Test voltage between braid and outside : 500 V AC
Video camera Cable
r
Spark test of jacket : 1500 V AC
Core A :
AWG 36 stranded silver
plated alloy.
FEP insulation
∅ = .24 ±.03mm
Core B :
AWG 36 stranded silver
plated alloy.
FEP insulation
∅ = .28 ±.05mm
Core C :
2 cores (A) twisted, pitch 5mm
nominal (8 mm maxi)
Kevlar member 158 TEX
Tensile strength > 20 kgF
2 core (C) + 14 cores (B) +
Kevlar member twisted, pitch
10mm nominal
∅ = 1.7mm max
PTFE tape
AWG 40 silver plated alloy
braid 95 % coverage , pitch
10mm nominal
∅ = 2.2mm nominal
PTFE tape ∅ = 2.4mm max
Polyurethane ∅ = 3.6mm max
Thickness .60 ± .05 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Ω /m nominal 2.2 Ω /m max
Thermal performances
r
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Issue 1 - November 2000
- 45 -
Filotex
STUDY 132182
8 x 36 AWG twisted pairs
+ 3 x 36 AWG wires
®
Dental cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
r
Video endoscopy cable assemblies
Electrical performances
PRODUCT REFERENCES
FILOTEX Ref : ET 132182
r
Linear capacitance core (C) : 60 pF/m maxi
r
Linear capacitance between 2 cores (B) : 15 pF/m nominal
r
Linear capacitance between cores (C) and braid : To be define on
sample
CONSTRUCTION
Video camera Cable
• Core A :AWG 36 stranded silver
plated alloy.
FEP insulation ∅ = .24 ± .03mm
‚ Core B :AWG 36 stranded silver
plated alloy.
FEP insulation ∅ = .28 ± .05mm
ƒ Core C : 2 cores (A) twisted, pitch
8mm nominal(10 mm maxi)
„ Kevlar member 158 TEX
Tensile strength > 20 kgF
… Core D : 3 cores (B) twisted +
Kevlar member, pitch 9mm
nominal (12mm maxi)
1 core (D) + 8 cores (C) twisted,
pitch 15 to 25mm
∅ = 1.7mm max
† PTFE tape unsintered
‡ AWG 42 hard silver plated alloy
braid 95 % coverage , pitch
10mm nominal
∅ = 2.15mm nominal
ˆ PTFE tape unsintered
∅ = 2.35mm max
‰ Polyurethane ∅ = 3.6mm max
Thickness .60 ± .05mm
All copper alloy are without
cadmium.
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
All capacitance must be verify on a sample
r
DC resistance core (A) & (B) : 1.52
r
Test voltage conductor/conductor : 500 VAC
r
Spark test of jacket : 1500 VAC
Ω /m nominal . 1.6 Ω /m max.
Thermal performances
r
Operating temperature : - 30°C to + 85°C (100°C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
9
8
7
6
5
4
3
2
1
Issue 1 - November 2000
- 46 -
Part 6
Microcables for
other medical applications
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 47 -
Microcables for
Catheter
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 48 -
Filotex
STUDY 132183
3 x 2 wires 44 AWG
®
Cable for catheter
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
Ultrasound cable assemblies
PRODUCT REFERENCES
r
FILOTEX Ref : ET 132 183
Electrical performances
r
Continuous operating voltage : 24 V eff.
r
Test voltage between core and screen : 350 V DC 1 mn
Thermal performances
r
CONSTRUCTION
•
Core A :
AWG 44 silver plated
copper.
Enamel lacquer
∅ =.06 ±.005 mm
‚
Core B :
2 cores A twisted
∅ =.12mm
Operating temperature : - 30°C to +150 °C (200°C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
3 cores (B) twisted
∅ =.22mm nominal
ƒ
AWG 48 silver plated copper
spiral shield
∅ = .28mm nominal
„
FEP ∅ = .40 ± .02 mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 49 -
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Filotex
STUDY 124524
5 x 30 AWG wires
®
Cable for catheter
Characteristics
PRODUCT REFERENCES
r
Very flexible cable with an extremely good mechanical
behaviour.
FILOTEX Ref : ET 124 524
Electrical performances
r
Continuous operating voltage : 250 V
Thermal performances
r
CONSTRUCTION
•
‚
ƒ
„
…
†
Operating temperature : - 60°C to +85 °C
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Core A :
AWG 30 stranded silver
plated copper.
PTFE insulation
∅ = .61 ±.05mm
Core B :
AWG 30 stranded silver
plated copper drain wire.
Core C :
2 cores (A) + 1 core (B)
twisted
Polyester/Aluminium tape
1 core (C) + 3 cores (A)
twisted
PTFE tape
∅ = 5.55 mm nominal
AWG 38 tin plated copper
helicoidal screen.
Polyurethane
∅ = 3.55 ±.15mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 50 -
Microcables for
patient monitoring
(invasive applications)
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 51 -
Filotex
STUDY 123546
2 channels 36 AWG
coax cable
®
Medical cable for patient monitoring
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
PRODUCT REFERENCES
FILOTEX Ref : ET 123 546
CONSTRUCTION
Multi coax 95pF/m
Core A :
AWG 36 silver plated alloy
wire.
FEP insulation
∅ = .32 ± .03mm
AWG 44 silver plated
copper
Helicoidal screen
∅ =.42mm nominal
FEP jacket ∅ = .52 ±
.03mm
2 Cores (A) + 2 cores (B)
twisted
∅ = 1.02 mm nominal
•
‚
ƒ
AWG 44 tin plated copper
helicoidal screen
∅ = 1.12mm nominal
r
Very flexible cable with an extremely good mechanical behaviour
r
Withstands miscellaneous sterilisation processes
Applications
r Ultrasound cable assemblies
Electrical performancess
r
Characteristic impedance
: 50 nominal
r
Linear capacitance
: 95 ± 10 pF/m (at 95%) (29pF/ft)
r
Continuous operating voltage
: 24 V eff.
r
Test voltage between core and screen
: 350 V DC 1 mn
Thermal performances
r
Operating temperature
: - 30°C to + 85 °C (100°C at peak)
Mechanical performances
r
Minimum bending radius
: 5 x Overall diameter
3
2
1
Superpolyamide
∅ = 1.5 ± 1 mm
This cable is not round.
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 52 -
Microcables for
ECG
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 53 -
Filotex®
STUDY 022595
ECG cable
Medical ECG cable
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
PRODUCT REFERENCES
r
Very flexible cable with an extremely good mechanical
behaviour.
r
Withstands miscellaneous sterilisation processes.
Applications
r
ECG cable assemblies.
FILOTEX Ref : ET 022 595
Electrical performances
r
Continuous operating voltage : 250 V eff.
Thermal performances
r
CONSTRUCTION
Low noise cable
Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
• 24 x .05 mm stranded
copper
∅ = .28 mm nominal
‚
Polyethylene insulation
∅ = .70 ± .05mm
ƒ
Semi-conductive layer
∅ = .73mm nominal
„
.07 mm copper braid
∅ = 1mm nominal
…
PVC jacket
∅ = 1.4mm nominal.
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 54 -
Temporary myocard
pacing wire
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 55 -
Passing on or copying of the document, use or communicate of its conte nt is not permitted without prior written authorization. Information subject to change without notice.
Filotex
STUDY 060517
®
Temporary myocard pacing wire
Characteristics
PRODUCT REFERENCES
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes
FILOTEX Ref : ET 060 517
Electrical performances
CONSTRUCTION
•
19 x 0.06 stranded stainless
steel 316L
‚
PE insulation
∅ = .65 ± .03mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
DC resistance : ≤ 16 Ω/m
r
Insulation resistance : ≥ 100 MΩ.km
r
Dielectric strength : ≥ 1500 V DC
Thermal performances
r
Operating temperature : - 50°C to + 200 °C
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter .
r
Pull-off force : 5 N to 15 N
Issue 1 - November 2000
- 56 -
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Filotex
STUDY 132070
®
Temporary myocard pacing wire
Characteristics
PRODUCT REFERENCES
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes
FILOTEX Ref : ET 132 070
Electrical performances
CONSTRUCTION
•
19 x 0.044 stranded stainless
steel 316L ∅ = .22 ± .02mm
‚
PE insulation
∅ = .48 ± .02mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
r
DC resistance : ≤ 30 Ω/m
r
Insulation resistance : ≥ 100 MΩ.km
r
Dielectric strength : ≥ 1500 V DC
Thermal performances
r
Operating temperature : - 50°C to + 200 °C
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter .
r
Pull-off force : 5 N to 15 N
Issue 1 - November 2000
- 57 -
Filotex
STUDY 132524
®
Temporary myocard pacing wire
Passing on or copying of the document, use or communicate of its content is not permitted without prior written authorization. Information subject to change without notice.
Characteristics
PRODUCT REFERENCES
FILOTEX Ref : ET 132 524
CONSTRUCTION
•
‚
19 x .044 mm stranded
stainless steel 316L
∅ = .22 ± .02 mm
r
Very flexible cable with an extremely good mechanical behaviour.
r
Withstands miscellaneous sterilisation processes.
Electrical performances
r
DC resistance of inner conductor : ≤ 50 Ω/m
r
DC resistance of outer conductor : ≤ 30 Ω/m
r
Insulation resistance of insulation : ≥ 100 MΩ.km
r
Insulation resistance of jacket : ≥ 100 MΩ.km
r
Dielectric strength : ≥ 1500 V DC
Thermal performances
r
Operating temperature : - 30°C to + 75°C
Mechanical performances
r
Minimum bending radius : 5 x Overall diameter
Polyethylene insulation
∅ = .40 ± .02 mm
ƒ 0.044 mm stainless steel
316L
helicoidal screen
min. coverage 90 %
∅ = .49 ± .02 mm
„
Polyethylene jacket
∅ = .75 ± .05mm
140 – 146 rue E. Delacroix / BP 1
F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00
Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 58 -
Download