AWG 26 AWG 26

advertisement
Net price including copper
Suitable for: connections in and between electrical systems, control systems, regulation systems,
measurement systems, signalling systems and pulsed signal systems, especially if the cable must be
shielded against external interference, and if the products are intended for export to the USA.
No live core conductor
Connection system: low-cost connection using insulation displacement connectors.
Small conductor and
cable diameters
Core structure: as per Style No.1061 and VDE 0881, copper strands 7 x 0.16 mm Ø tinned = 0.14 mm2,
insulated with semi-rigid PVC. Insulation wall thickness 0.25 mm, Ø of insulated conductor 1.0 mm.
No twist markings
Core labelling: international colour code (see page 228).
Will not break under
vibration
Twisted structure: starting with the black conductor, the conductors
are twisted clockwise layer by layer from inside out to form the cable core.
Ductile fractures are avoided, as the cables do not contain any live central conductors.
Very flexible
Heat resistant
Cold resistant
Oil resistant to a limited
extent
Petrol resistant to a
limited extent
Flame-retardant
as per UL VW-1/CSA FT-1
Wrapping and shield: The twisted conductors are wrapped in overlapping transparent plastic foil and
shielded with a dense braid of tinned copper wires, visual coverage ≥ 85%.
Outer jacket: matte black made of special PVC. Colour RAL 9005. No twist markings.
The PVC mixture is oil resistant to a limited extent, petrol resistant to a limited extent, flame-retardant,
weather resistant and ultraviolet resistant.
The wall thickness of the outer jacket increases gradually with the number of conductors from 0.8 mm
(2-conductor) to 1.0 mm (48-conductor).
Temperature range:
Cold resistant
Electrical properties:
Operating voltage
Heat resistant
105°C as per DIN ISO 6722 (outer jacket)
80°C (Cores)
-10°C unrolling and installing
-30°C storage and operation
Resistant to weathering
Ultraviolet resistant
Suitable for
insulation displacement
and crimp connectors
Certified:
UL - Style No. 2464
UL - Style No. 1061
Test voltage
300 V
1,500 V
Sample
quantities
under
100 metres
2.6 kg
2.8 kg
3.1 kg
4.0 kg
5.3 kg
5.8 kg
6.1 kg
6.2 kg
6.7 kg
9.6 kg
10.4 kg
11.1 kg
12.9 kg
15.9 kg
4.2 mm
4.3 mm
4.6 mm
5.2 mm
6.0 mm
6.2 mm
6.4 mm
7.0 mm
7.3 mm
8.4 mm
8.5 mm
8.8 mm
9.4 mm
10.6 mm
2
3
4
6
8
10
12
16
18
24
27
30
36
48
1.80
1.90
2.20
2.50
2.90
3.50
3.90
4.70
5.30
6.70
7.10
7.20
9.50
12.50
Shielded
2 to 48 conductors
Ordering information
in EUR per 100 m
on collection
Price for 1 m
100 m
500 m
upwards upwards
120.00
128.00
148.00
164.00
192.00
232.00
260.00
312.00
356.00
444.00
472.00
480.00
632.00
812.00
90.00
96.00
111.00
123.00
144.00
174.00
195.00
234.00
267.00
333.00
354.00
360.00
474.00
609.00
AWG No.
Shield
Certification
Jacket colour
Technical data
Copper conductors in
AWG sizes, 7-wire,
UL 1061 and VDE 0881
AWG 26
Flexible shielded black control signal cables
AWG 26 = 0.14 mm2 (7 x 0.16, tinned)
UL Style
2464/1061
Number of conductors
Summary
UL Style
2464/1061
Cores
Flexible shielded black control signal cables
AWG 26 = 0.14 mm2 (7 x 0.16, tinned)
Overall Ø + 3%
Shielded
2 to 48 conductors
100 m weighs approx.
AWG 26
2
3
4
6
8
10
12
16
18
24
27
30
36
48
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk
26 C UL bk‫٭‬
26 C UL bk
26 C UL bk
Normal stock unit: 100-m ring. Short sample (20 cm) free of charge.
The rings are marked with the
label.
(Cutlenght are without Label)
This label is the proof of certification in the USA.
Conductor resistance(20°C) 155 Ω/km
Insulation resistance
Operating capacitance
Mechanical properties:
On-time
(20°C) ≥ 20 MΩ X km
One conductor to the remaining conductors,
shield earthed approx. 130 pF/metre.
Once-only bending radius 5 X outer diameter
Repeated bending radius 20 X outer diameter
.
Fast
.
Reliable
‫٭‬Items to be sold off
On-time
.
Fast
.
Reliable
Download