Net price including copper Suitable for: connections in and between electrical systems, control systems, regulation systems, measurement systems, signalling systems and pulsed signal systems, especially if the cable must be shielded against external interference, and if the products are intended for export to the USA. No live core conductor Connection system: low-cost connection using insulation displacement connectors. Small conductor and cable diameters Core structure: as per Style No.1061 and VDE 0881, copper strands 7 x 0.16 mm Ø tinned = 0.14 mm2, insulated with semi-rigid PVC. Insulation wall thickness 0.25 mm, Ø of insulated conductor 1.0 mm. No twist markings Core labelling: international colour code (see page 228). Will not break under vibration Twisted structure: starting with the black conductor, the conductors are twisted clockwise layer by layer from inside out to form the cable core. Ductile fractures are avoided, as the cables do not contain any live central conductors. Very flexible Heat resistant Cold resistant Oil resistant to a limited extent Petrol resistant to a limited extent Flame-retardant as per UL VW-1/CSA FT-1 Wrapping and shield: The twisted conductors are wrapped in overlapping transparent plastic foil and shielded with a dense braid of tinned copper wires, visual coverage ≥ 85%. Outer jacket: matte black made of special PVC. Colour RAL 9005. No twist markings. The PVC mixture is oil resistant to a limited extent, petrol resistant to a limited extent, flame-retardant, weather resistant and ultraviolet resistant. The wall thickness of the outer jacket increases gradually with the number of conductors from 0.8 mm (2-conductor) to 1.0 mm (48-conductor). Temperature range: Cold resistant Electrical properties: Operating voltage Heat resistant 105°C as per DIN ISO 6722 (outer jacket) 80°C (Cores) -10°C unrolling and installing -30°C storage and operation Resistant to weathering Ultraviolet resistant Suitable for insulation displacement and crimp connectors Certified: UL - Style No. 2464 UL - Style No. 1061 Test voltage 300 V 1,500 V Sample quantities under 100 metres 2.6 kg 2.8 kg 3.1 kg 4.0 kg 5.3 kg 5.8 kg 6.1 kg 6.2 kg 6.7 kg 9.6 kg 10.4 kg 11.1 kg 12.9 kg 15.9 kg 4.2 mm 4.3 mm 4.6 mm 5.2 mm 6.0 mm 6.2 mm 6.4 mm 7.0 mm 7.3 mm 8.4 mm 8.5 mm 8.8 mm 9.4 mm 10.6 mm 2 3 4 6 8 10 12 16 18 24 27 30 36 48 1.80 1.90 2.20 2.50 2.90 3.50 3.90 4.70 5.30 6.70 7.10 7.20 9.50 12.50 Shielded 2 to 48 conductors Ordering information in EUR per 100 m on collection Price for 1 m 100 m 500 m upwards upwards 120.00 128.00 148.00 164.00 192.00 232.00 260.00 312.00 356.00 444.00 472.00 480.00 632.00 812.00 90.00 96.00 111.00 123.00 144.00 174.00 195.00 234.00 267.00 333.00 354.00 360.00 474.00 609.00 AWG No. Shield Certification Jacket colour Technical data Copper conductors in AWG sizes, 7-wire, UL 1061 and VDE 0881 AWG 26 Flexible shielded black control signal cables AWG 26 = 0.14 mm2 (7 x 0.16, tinned) UL Style 2464/1061 Number of conductors Summary UL Style 2464/1061 Cores Flexible shielded black control signal cables AWG 26 = 0.14 mm2 (7 x 0.16, tinned) Overall Ø + 3% Shielded 2 to 48 conductors 100 m weighs approx. AWG 26 2 3 4 6 8 10 12 16 18 24 27 30 36 48 X X X X X X X X X X X X X X AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk 26 C UL bk٭ 26 C UL bk 26 C UL bk Normal stock unit: 100-m ring. Short sample (20 cm) free of charge. The rings are marked with the label. (Cutlenght are without Label) This label is the proof of certification in the USA. Conductor resistance(20°C) 155 Ω/km Insulation resistance Operating capacitance Mechanical properties: On-time (20°C) ≥ 20 MΩ X km One conductor to the remaining conductors, shield earthed approx. 130 pF/metre. Once-only bending radius 5 X outer diameter Repeated bending radius 20 X outer diameter . Fast . Reliable ٭Items to be sold off On-time . Fast . Reliable