T5 Fluorescent Fixture Series GE Lighting Installation, Use and Maintenance Manual READ THROUGHLY BEFORE INSTALLATION SAVE THESE INSTRUCTIONS FOR FUTURE USE These Instructions do not purport to cover all details or variations in luminaire nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problem arise which are not covered sufficiently for the purchaser’s purpose, the matter should be referred to General Electric Company. I. The Manufacturer has made every effort during the design and construction stages to make its products completely free of risks when correctly used. Note however that accident prevention and safety regulations stipulate that the users of the product is obliged to ensure that all persons involved in servicing, installing, handling, using or selling the products are familiar with the information supplied by the Manufacturer and fully aware of any precautions that must be adopted. Depending on the circumstances, the instructions in this document must be communicated, together with any other information that may be necessary, to any Company or person involved in the installation of GE lighting products. II. UNPACKING The luminaire has been properly packed to avoid damage during transit. Inspect the luminaries to confirm there is no damage. Do not install a damaged luminaire or damaged luminaire components. The carton consists of: Fixture Leaflet Accessories IP20 220-240V~, 50/60Hz WARNING GENERAL This luminaire has a beautiful outline, be compact, lightweight and easy to use. It also has the features of soft light, safety and high efficiency. It is main designed for indoor lighting application, and should not be used in areas of limited ventilations, or in high ambient temperature enclosures. It is suitable for mounting on a normally flammable surface. Best results will be obtained if installed and maintained according to the following recommendations. Please refer section III for the application limitation details. Class II CAUTION FOR ELECTRIC SHOCK/RISK OF BURN/PROPER INSTALLATION Non-professionals are not allowed to operate. Shut off the power before maintenance. Risk of burn, allow lamps/fixture to cool down before handling. III. APPLICATION NOTICE PLEASE APPLY THE PRODUCT ACCORDING TO FOLLOWING STATEMENT This is a fixed general-purpose luminaire mounted with fluorescent lamp, which can be used for interior installation, or connect to a series. Application can be in kitchen, shopping market & office building. VI. INSTALLATION WARNING Ensure this manual is provided to the installers and users; Cut off the power before installation and maintenance; If series connection is applied, the luminaire quantities must be not more than 10. This fixture is only used for indoor, under no circumstances be used in high temperature and high humidity environment. CAUTION Risk of Injury Luminaire may fall down if not installed properly, follow installation instructions Ware safety glasses and proper aid during installation and maintenance TOOLS/ACCESSRIES YOU WILL NEED Screwdriver – (6~12mm): Used for drive the screw in for the mounting INSTALL LUMINAIRE 1. Install Luminaire The luminaire can be installed at a fixed surface with two brackets. (See Fig.1) (Fig.1) Step by Step: 1) Confirm the installation room, and refer to section VI the size of luminaire. 2) Install the two brackets to fixed surface with screws of provided. (Ensuring that the screws don’t touch any obstructions such as cables, water pipes, etc.) 3) Fix the luminaire to the two brackets directly. 4) Adjust luminaire to desirable position. 5) Refer to section V for installation of lamp. 2. Series connection Fixture can be connected by two ways, and the maximum allowable connection quantity is 10 pieces. (See Fig.2) Wiring Series connection Coupler Series connection (Fig. 2) Notice: Luminaires suitable for direct mounting on normally flammable surfaces. V. MAINTENANCE/ LAMP REPLACEMENT FAILURE PARTS NEED TO BE REPLACED IF YOU INSPECT THE LAMP EXTINCT, FLICKING OR CYCLING. ORDER THE REPLACEMENT PART INDIVIDUALLY. CONTACT THE MANUFACTURES FOR THE MAINTENANCE SERVICE. LAMP REPLACEMENT Light output is also dependent on burning time of lamp. In applications where light levels are critical, it may be desirable to replace lamps before the end of life. Lamp manufacturer can provide life curve datasheet of light output 1) Shut off power. 2) Carefully remove the diffuser if have. 3) Use one hand to push the both side of end cap and another hand release the cover. (See Fig.3) 4) Turn 90°and remove the lamps to be replaced. 5) Re-install the luminaire in line with the requirements of qualified lamp. 6) Restore. WARNING Please note the lamp type, wattage shall be same as the indication of the product label. Cut off the power before installation, and let lamp and fixture cool down. The diffuser is frangible, cannot press hardly. If lamp is handled, fingerprint, grease or oils should be removed from lamp with isopropyl alcohol. This will remove material that will cause whitish spotting, and premature lamp failure. Dry lamp carefully with cotton or clean cloth. GE T5 Starcoat ™ lamp is recommended VI. PRODUCT INFORMATION PRODUCT BASIC INFO Description Lamp & Power Rating Voltage Power Current Frequency PF (Fig.3) Max Series Recommended Current GE lamp Size mm (LWH) 220-240V~ 0.075A 50/60Hz 0.95 0.85A F8T5 31824.547 DMS 14 Series T5 LFL 1x14W 220-240V~ 0.13A 50/60Hz 0.95 1.4A F14W/T5/HE 57924.547 DMS 21 Series T5 LFL 1x21W 220-240V~ 0.11A 50/60Hz 0.95 2A F21W/T5/HE 87924.547 DMS 28 Series T5 LFL 1x28W 220-240V~ 0.14A 50/60Hz 0.95 1.5A F28W/T5/HE 117924.547 DMS 08 Series T5 LFL 1x8W In addition to above introduction, we are also providing multiple combinations to customer, including with/without diffuser, different lamp color temperature, package and accessories. For detail information please contact GE’s sales team or distribution agency. PRODUCT DIMENSIONS AND OUTLINES (mm) GE Lighting Co., Ltd. No. 88, Lane 1517, Hu Yi Gong Road, Jiading District, Shanghai, 201802, P.R.C +86-800-820-9992 www.gelighting.com