MARSDEN PARK

advertisement
04.04.14
11.04.14
01.05.14
24.07.14
04.09.14
24.09.14
DATE OF ISSUE
DRAWING PACKAGE VERSION
1
2
3
4
5
6
01
01
01
01
02
02
02
02
02
03
03
03
03
04
04
04
04
05
05
05
04
05
05
06
ARCHITECTURAL DRAWINGS
3200028-A1
3200028-A2
3200028-A3
3200028-A4
SITE SPECIFICATIONS AND LOCALITY PLAN
OVERALL SITE PLAN
SITE SETOUT PLAN
SITE ELEVATION
MARSDEN PARK
879 RICHMOND ROAD
MARSDEN PARK
NSW 2765
STRUCTURAL DRAWINGS
ELECTRICAL DRAWINGS
CCI SITE NO: 3200028
EME/RF DRAWINGS
EQUIPMENT SHELTER / FITOUT ROOM
SURVEY / LEASE DIAGRAMS
Level 1, Solitaire
12 Help Street, Chatswood
REFERENCE DOCUMENTS
DALY INT.
LEAH POULTON
CORY NAGEL
NSW 2067 Australia
+61 2 8241 9800
www.dalyinternational.com
1
1
1
1
1
1
1
1
COPIES
1
1
1
1
Status:
A3 Original Sheet Size
PRELIMINARY
Drawing No:
3200028-00
Revision:
06
SITE INFORMATION:
1. SITE ADDRESS
879 RICHMOND ROAD
MARSDEN PARK
NSW 2765
2. GENERAL
THE CONTRACTOR SHALL COMPLY WITH ALL RELEVANT CROWN CASTLE
CONSTRUCTION STANDARDS, AUSTRALIAN STANDARDS AND SPECIFICATIONS.
3. SITE ACCESS
SITE ACCESS VIA EXISTING DRIVEWAY.
4. EQUIPMENT
EQUIPMENT DETAILS TO BE CONFIRMED BY INDIVIDUAL CARRIERS.
5. STRUCTURE
PROPOSED 50m HIGH LATTICE TOWER.
6. ANTENNA ACCESS
ANTENNA ACCESS VIA TOWER CLIMBING LADDER (BY QUALIFIED RIGGER
PERSONNEL ONLY).
REGIONAL MAP
7. EXISTING SERVICES
THE CONTRACTOR SHALL IDENTIFY AND CONFIRM THE LOCATION OF ALL
RELEVANT EXISTING SERVICES AS REQUIRED PRIOR TO THE COMMENCEMENT OF
WORKS.
SITE LOCATION
8. EXISTING SITE HAZARDS
THE FOLLOWING HAZARDS ARE PRESENT ON SITE:
- WORKING AT HEIGHTS
- SLIP, TRIP AND FALLS
- MACHINERY
- WEATHER/ LIGHTNING
- SUN EXPOSURE
- VEHICULAR TRAFFIC
DATUM:
ZONE:
EASTING (m):
NORTHING (m):
DATUM:
GDA 94
56
GDA 94
ZONE:
56
LAT. (Degrees):
300 282
6 267 447
-33.714195
LONG. (Degrees): 150.844714
03
03
Design Contractor:
03
02
01
Issue
04.09.14 AS MARKED
11.04.14 NOTE 3 REVISED
04.04.14 PRELIMINARY ISSUE
Date
Revision Description
DI
DI
DI
JM
BRS
BRS
DI
DI
DI
CN
CN
CN
LM
LM
LM
9. ELECTRICAL SUPPLY
PROPOSED ELECTRICAL SUPPLY WILL BE FROM EXISTING BUILDING SUPPLY.
DETAILS TO BE CONFIRMED.
Project:
CROWN CASTLE
SITE NO:-3200028
MARSDEN PARK
879 RICHMOND ROAD
Client:
Drawing Title:
SITE SPECIFICATIONS AND
LOCALITY PLAN
Status:
Drawing No:
PRELIMINARY
3200028-A1
Revision:
03
A3 Original Sheet Size
SITE CO-ORDINATES
AMG
EXISTING RESIDENTIAL BUILDINGS
(TYP.)
/D
L49
L40/ DP1175138
PROPOSED COMPOUND
8
753
P11
EXISTING PROPERTY BOUNDARY
FENCE LINE
L41/ DP1175138
L102/
DP1169158
EXISTING DRIVEWAY
EXISTING DRAIN ALONG FRONT OF
PROPERTY
L42/ DP1175138
EXISTING CULVERT
L51
538
D
OA
DR
ON
117
HM
/ DP
RIC
OVERALL SITE PLAN
05
Design Contractor:
05
04
03
02
01
Issue
04.09.14
24.07.14
01.05.14
11.04.14
04.04.14
Date
NEW SITE LOCATION
COMPOUND REVISED
COMPOUND REVISED
LOT BOUNDARY ADDED
PRELIMINARY ISSUE
Revision Description
DI
DI
DI
DI
DI
JM
BRS
LM
BRS
BRS
DI
DI
DI
DI
DI
CN
CN
CN
CN
CN
LM
LM
LM
LM
LM
Project:
CROWN CASTLE
SITE NO:-3200028
MARSDEN PARK
879 RICHMOND ROAD
Client:
Drawing Title:
OVERALL SITE PLAN
Status:
Drawing No:
PRELIMINARY
3200028-A2
Revision:
05
A3 Original Sheet Size
SCALE 1:1000
AMG
PROPOSED 600 WIDE
ELEVATED CABLE
LADDER (BY OTHERS)
15000
ND)
MPOU
O
C
D
POSE
PROPOSED SECURITY
COMPOUND FENCE WITH
3m WIDE ACCESS GATES
(PRO
PROPOSED 50m HIGH
STEEL LATTICE TOWER
PROPOSED EQUIPMENT
SHELTER (BY OTHERS)
INDICATIVE ANTENNAS
(BY OTHERS)
10000
ND)
MPOU
O
C
D
POSE
PROPOSED 450 WIDE ELEVATED
CABLE LADDER (BY OTHERS)
PROPOSED 450 WIDE ELEVATED
CABLE LADDER (BY OTHERS)
(PRO
PROPOSED EQUIPMENT
SHELTER (BY OTHERS)
PROPOSED EQUIPMENT
SHELTER (BY OTHERS)
PROPOSED UNDERGROUND
POWER ROUTE (SHOWN
INDICATIVE ONLY)
EXISTING
BUILDING TYP.
PROPOSED ACCESS TRACK
SITE SETOUT PLAN
SCALE 1:100
05
04
03
02
01
Issue
04.09.14
24.07.14
01.05.14
11.04.14
04.04.14
Date
NEW SITE LOCATION
COMPOUND REVISED
COMPOUND REVISED
COMPOUND REVISED, ANTENNAS ADDED
PRELIMINARY ISSUE
Revision Description
DI
DI
DI
DI
DI
JM
BRS
LM
BRS
BRS
DI
DI
DI
DI
DI
CN
CN
CN
CN
CN
LM
LM
LM
LM
LM
Project:
CROWN CASTLE
SITE NO:-3200028
MARSDEN PARK
879 RICHMOND ROAD
Client:
Drawing Title:
SITE SETOUT PLAN
Status:
Drawing No:
PRELIMINARY
3200028-A3
Revision:
05
A3 Original Sheet Size
Design Contractor:
NOTE:
TOWER FOUNDATION SIZE INDICATIVE ONLY FINAL SIZE
WILL BE DEPENDANT ON GEOTECHNICAL REPORT,
FOUNDATION DESIGN AND TOWER MODEL.
Design Contractor:
06
05
04
03
02
01
Issue
24.09.14
04.09.14
24.07.14
01.05.14
11.04.14
04.04.14
Date
SHELTER RAISED
COMPOUND LAYOUT REVISED
COMPOUND REVISED
COMPOUND REVISED
COMPOUND REVISED, ANTENNAS ADDED
PRELIMINARY ISSUE
Revision Description
DI
DI
DI
DI
DI
DI
BRS
JM
BRS
LM
BRS
BRS
DI
DI
DI
DI
DI
DI
CN
CN
CN
CN
CN
CN
LM
LM
LM
LM
LM
CN
Project:
CROWN CASTLE
SITE NO:-3200028
MARSDEN PARK
879 RICHMOND ROAD
Client:
SITE ELEVATION
Status:
Drawing No:
PRELIMINARY
3200028-A4
Revision:
06
A3 Original Sheet Size
Drawing Title:
PROPOSED SECURITY
COMPOUND FENCE WITH
3m WIDE ACCESS GATES
PROPOSED EQUIPMENT
SHELTER (BY OTHERS)
PROPOSED 50m HIGH
STEEL LATTICE TOWER
EL 0.00m
GROUND LEVEL
EXISTING
BUILDING TYP.
EL 37.50m (TBC)
INDICATIVE ANTENNAS (BY OTHERS)
EL 40.00m (TBC)
INDICATIVE ANTENNAS (BY OTHERS)
EL 42.50m (TBC)
INDICATIVE ANTENNAS (BY OTHERS)
EL 45.00m (TBC)
INDICATIVE ANTENNAS (BY OTHERS)
EL 50.00m
TOP OF TOWER
INDICATIVE ANTENNAS (BY OTHERS)
EL 47.50m (TBC)
INDICATIVE ANTENNAS (BY OTHERS)
EL 55.00m
TOP OF LIGHTING FINIAL
SCALE 1:200
SOUTHERN ELEVATION
NOTE: DETAILS OF EQUIPMENT TO BE INSTALLED ON TOWER
TO BE CONFIRMED AT A LATER TIME.
Download