04.04.14 11.04.14 01.05.14 24.07.14 04.09.14 24.09.14 DATE OF ISSUE DRAWING PACKAGE VERSION 1 2 3 4 5 6 01 01 01 01 02 02 02 02 02 03 03 03 03 04 04 04 04 05 05 05 04 05 05 06 ARCHITECTURAL DRAWINGS 3200028-A1 3200028-A2 3200028-A3 3200028-A4 SITE SPECIFICATIONS AND LOCALITY PLAN OVERALL SITE PLAN SITE SETOUT PLAN SITE ELEVATION MARSDEN PARK 879 RICHMOND ROAD MARSDEN PARK NSW 2765 STRUCTURAL DRAWINGS ELECTRICAL DRAWINGS CCI SITE NO: 3200028 EME/RF DRAWINGS EQUIPMENT SHELTER / FITOUT ROOM SURVEY / LEASE DIAGRAMS Level 1, Solitaire 12 Help Street, Chatswood REFERENCE DOCUMENTS DALY INT. LEAH POULTON CORY NAGEL NSW 2067 Australia +61 2 8241 9800 www.dalyinternational.com 1 1 1 1 1 1 1 1 COPIES 1 1 1 1 Status: A3 Original Sheet Size PRELIMINARY Drawing No: 3200028-00 Revision: 06 SITE INFORMATION: 1. SITE ADDRESS 879 RICHMOND ROAD MARSDEN PARK NSW 2765 2. GENERAL THE CONTRACTOR SHALL COMPLY WITH ALL RELEVANT CROWN CASTLE CONSTRUCTION STANDARDS, AUSTRALIAN STANDARDS AND SPECIFICATIONS. 3. SITE ACCESS SITE ACCESS VIA EXISTING DRIVEWAY. 4. EQUIPMENT EQUIPMENT DETAILS TO BE CONFIRMED BY INDIVIDUAL CARRIERS. 5. STRUCTURE PROPOSED 50m HIGH LATTICE TOWER. 6. ANTENNA ACCESS ANTENNA ACCESS VIA TOWER CLIMBING LADDER (BY QUALIFIED RIGGER PERSONNEL ONLY). REGIONAL MAP 7. EXISTING SERVICES THE CONTRACTOR SHALL IDENTIFY AND CONFIRM THE LOCATION OF ALL RELEVANT EXISTING SERVICES AS REQUIRED PRIOR TO THE COMMENCEMENT OF WORKS. SITE LOCATION 8. EXISTING SITE HAZARDS THE FOLLOWING HAZARDS ARE PRESENT ON SITE: - WORKING AT HEIGHTS - SLIP, TRIP AND FALLS - MACHINERY - WEATHER/ LIGHTNING - SUN EXPOSURE - VEHICULAR TRAFFIC DATUM: ZONE: EASTING (m): NORTHING (m): DATUM: GDA 94 56 GDA 94 ZONE: 56 LAT. (Degrees): 300 282 6 267 447 -33.714195 LONG. (Degrees): 150.844714 03 03 Design Contractor: 03 02 01 Issue 04.09.14 AS MARKED 11.04.14 NOTE 3 REVISED 04.04.14 PRELIMINARY ISSUE Date Revision Description DI DI DI JM BRS BRS DI DI DI CN CN CN LM LM LM 9. ELECTRICAL SUPPLY PROPOSED ELECTRICAL SUPPLY WILL BE FROM EXISTING BUILDING SUPPLY. DETAILS TO BE CONFIRMED. Project: CROWN CASTLE SITE NO:-3200028 MARSDEN PARK 879 RICHMOND ROAD Client: Drawing Title: SITE SPECIFICATIONS AND LOCALITY PLAN Status: Drawing No: PRELIMINARY 3200028-A1 Revision: 03 A3 Original Sheet Size SITE CO-ORDINATES AMG EXISTING RESIDENTIAL BUILDINGS (TYP.) /D L49 L40/ DP1175138 PROPOSED COMPOUND 8 753 P11 EXISTING PROPERTY BOUNDARY FENCE LINE L41/ DP1175138 L102/ DP1169158 EXISTING DRIVEWAY EXISTING DRAIN ALONG FRONT OF PROPERTY L42/ DP1175138 EXISTING CULVERT L51 538 D OA DR ON 117 HM / DP RIC OVERALL SITE PLAN 05 Design Contractor: 05 04 03 02 01 Issue 04.09.14 24.07.14 01.05.14 11.04.14 04.04.14 Date NEW SITE LOCATION COMPOUND REVISED COMPOUND REVISED LOT BOUNDARY ADDED PRELIMINARY ISSUE Revision Description DI DI DI DI DI JM BRS LM BRS BRS DI DI DI DI DI CN CN CN CN CN LM LM LM LM LM Project: CROWN CASTLE SITE NO:-3200028 MARSDEN PARK 879 RICHMOND ROAD Client: Drawing Title: OVERALL SITE PLAN Status: Drawing No: PRELIMINARY 3200028-A2 Revision: 05 A3 Original Sheet Size SCALE 1:1000 AMG PROPOSED 600 WIDE ELEVATED CABLE LADDER (BY OTHERS) 15000 ND) MPOU O C D POSE PROPOSED SECURITY COMPOUND FENCE WITH 3m WIDE ACCESS GATES (PRO PROPOSED 50m HIGH STEEL LATTICE TOWER PROPOSED EQUIPMENT SHELTER (BY OTHERS) INDICATIVE ANTENNAS (BY OTHERS) 10000 ND) MPOU O C D POSE PROPOSED 450 WIDE ELEVATED CABLE LADDER (BY OTHERS) PROPOSED 450 WIDE ELEVATED CABLE LADDER (BY OTHERS) (PRO PROPOSED EQUIPMENT SHELTER (BY OTHERS) PROPOSED EQUIPMENT SHELTER (BY OTHERS) PROPOSED UNDERGROUND POWER ROUTE (SHOWN INDICATIVE ONLY) EXISTING BUILDING TYP. PROPOSED ACCESS TRACK SITE SETOUT PLAN SCALE 1:100 05 04 03 02 01 Issue 04.09.14 24.07.14 01.05.14 11.04.14 04.04.14 Date NEW SITE LOCATION COMPOUND REVISED COMPOUND REVISED COMPOUND REVISED, ANTENNAS ADDED PRELIMINARY ISSUE Revision Description DI DI DI DI DI JM BRS LM BRS BRS DI DI DI DI DI CN CN CN CN CN LM LM LM LM LM Project: CROWN CASTLE SITE NO:-3200028 MARSDEN PARK 879 RICHMOND ROAD Client: Drawing Title: SITE SETOUT PLAN Status: Drawing No: PRELIMINARY 3200028-A3 Revision: 05 A3 Original Sheet Size Design Contractor: NOTE: TOWER FOUNDATION SIZE INDICATIVE ONLY FINAL SIZE WILL BE DEPENDANT ON GEOTECHNICAL REPORT, FOUNDATION DESIGN AND TOWER MODEL. Design Contractor: 06 05 04 03 02 01 Issue 24.09.14 04.09.14 24.07.14 01.05.14 11.04.14 04.04.14 Date SHELTER RAISED COMPOUND LAYOUT REVISED COMPOUND REVISED COMPOUND REVISED COMPOUND REVISED, ANTENNAS ADDED PRELIMINARY ISSUE Revision Description DI DI DI DI DI DI BRS JM BRS LM BRS BRS DI DI DI DI DI DI CN CN CN CN CN CN LM LM LM LM LM CN Project: CROWN CASTLE SITE NO:-3200028 MARSDEN PARK 879 RICHMOND ROAD Client: SITE ELEVATION Status: Drawing No: PRELIMINARY 3200028-A4 Revision: 06 A3 Original Sheet Size Drawing Title: PROPOSED SECURITY COMPOUND FENCE WITH 3m WIDE ACCESS GATES PROPOSED EQUIPMENT SHELTER (BY OTHERS) PROPOSED 50m HIGH STEEL LATTICE TOWER EL 0.00m GROUND LEVEL EXISTING BUILDING TYP. EL 37.50m (TBC) INDICATIVE ANTENNAS (BY OTHERS) EL 40.00m (TBC) INDICATIVE ANTENNAS (BY OTHERS) EL 42.50m (TBC) INDICATIVE ANTENNAS (BY OTHERS) EL 45.00m (TBC) INDICATIVE ANTENNAS (BY OTHERS) EL 50.00m TOP OF TOWER INDICATIVE ANTENNAS (BY OTHERS) EL 47.50m (TBC) INDICATIVE ANTENNAS (BY OTHERS) EL 55.00m TOP OF LIGHTING FINIAL SCALE 1:200 SOUTHERN ELEVATION NOTE: DETAILS OF EQUIPMENT TO BE INSTALLED ON TOWER TO BE CONFIRMED AT A LATER TIME.