Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Measuring Instrument DC voltage 0 mV to < 330 mV 0.33 V to < 3.3 V 3.3 V to < 33 V 33 V to < 330 V 330 V to 1 020 V AC voltage 1 mV to < 33 mV 10 Hz to 45 Hz > 45 Hz to 10 kHz > 10 kHz to 20 kHz > 20 kHz to 50 kHz > 50 kHz to 100 kHz > 100 kHz to 500 kHz Temporary Best Measurement Capability* 70 µV/V + 3.9 µV 58 µV/V + 6.1 µV 58 µV/V + 59 µV 64 µV/V + 0.59 mV 64 µV/V + 1.9 mV 4.1 mV/V + 24 µV 1.8 mV/V + 24 µV 2.3 mV/V + 24 µV 2.9 mV/V + 24 µV 4.1 mV/V + 39 µV 12 mV/V + 70 µV Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP-01-101 by applying known voltage from multi - product calibrator In-house method : CP-01-102 by applying known voltage from multi - product calibrator * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 1/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Measuring Instrument AC voltage (cont.) 33 mV to < 330 mV 10 Hz to 45 Hz > 45 Hz to 10 kHz > 10 kHz to 20 kHz > 20 kHz to 50 kHz > 50 kHz to 100 kHz > 100 kHz to 500 kHz 0.33 V to < 3.3 V 10 Hz to 45 Hz > 45 Hz to 10 kHz > 10 kHz to 20 kHz > 20 kHz to 50 kHz Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark 2.9 mV/V + 58 µV 0.58 mV/V + 24 µV 1.2 mV/V + 24 µV 1.9 mV/V + 47 µV 2.8 mV/V + 0.20 mV 8.1 mV/V + 0.39 mV In-house method : CP-01-102 by applying known voltage from multi - product calibrator 1.8 mV/V + 0.29 mV 0.35 mV/V + 73 µV 0.93 mV/V + 72 µV 1.7 mV/V + 0.35 mV * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 2/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Measuring Instrument AC voltage 0.33 V to < 3.3 V (cont.) > 50 kHz to 100 kHz > 100 kHz to 500 kHz 3.3 V to < 33 V 10 Hz to 45 Hz > 45 Hz to 10 kHz > 10 kHz to 20 kHz > 20 kHz to 50 kHz > 50 kHz to 100 kHz 33 V to < 330 V 45 Hz to 1 kHz > 1 kHz to 10 kHz > 10 kHz to 20 kHz Temporary Mobile Best Measurement Capability* Standard/Technique/ Method/Equipment/Remark 2.8 mV/V + 2.0 mV 5.8 mV/V + 3.9 mV In-house method : CP-01-102 by applying known voltage from multi - product calibrator 1.8 mV/V + 2.9 mV 0.47 mV/V + 0.78 mV 0.93 mV/V + 3.1 mV 2.2 mV/V + 5.8 mV 2.8 mV/V + 20 mV 0.58 mV/V + 7.8 mV 0.93 mV/V + 18 mV 1.1 mV/V + 39 mV * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 3/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Measuring Instrument AC voltage (cont.) 330 V to 1020 V 45 Hz to 1 kHz > 1 kHz to 5 kHz > 5 kHz to 10 kHz DC current 0 mA to < 3.3 mA 3.3 mA to < 33 mA 33 mA to < 330 mA 330 mA to < 2.2 A 2.2 A to 11 A Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark 0.58 mV/V + 93 mV 2.4 mV/V + 0.12 V 2.4 mV/V + 0.58 V In-house method : CP-01-102 by applying known voltage from multi - product calibrator In-house method : CP0.16 mA/A + 58 nA 01-103 by applying known 0.12 mA/A + 0.29 µA current from multi 0.12 mA/A + 3.9 µA product calibrator 0.35 mA/A + 52 µA 0.70 mA/A + 0.39 mA * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 4/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Measuring Instrument AC current 0.029 mA to < 0.33 mA 10 Hz to 20 Hz > 20 Hz to 45 Hz > 45 Hz to 1 kHz > 1 kHz to 5 kHz > 5 kHz to 10 kHz 0.33 mA to < 3.3 mA 10 Hz to 20 Hz > 20 Hz to 45 Hz > 45 Hz to 1 kHz > 1 kHz to 5 kHz > 5 kHz to 10 kHz Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-104 by applying known current from multi 2.9 mA/A + 0.18 µA product calibrator 1.5 mA/A + 0.18 µA 1.5 mA/A + 0.29 µA 4.7 mA/A + 0.18 µA 15 mA/A + 0.18 µA 2.3 mA/A + 0.35 µA 1.2 mA/A + 0.35 µA 1.2 mA/A + 0.35 µA 2.3 mA/A + 0.35 µA 7.0 mA/A + 0.35 µA * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 5/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Measuring Instrument AC current (cont.) 3.3 mA to < 33 mA 10 Hz to 20 Hz > 20 Hz to 45 Hz > 45 Hz to 1 kHz > 1 kHz to < 5 kHz > 5 kHz to 10 kHz 33 mA to < 330 mA 10 Hz to 20 Hz > 20 Hz to 45 Hz > 45 Hz to 1 kHz > 1 kHz to 5 kHz > 5 kHz to 10 kHz Temporary Best Measurement Capability* 2.3 mA/A + 3.5 µA 1.2 mA/A + 3.5 µA 1.1 mA/A + 3.5 µA 2.3 mA/A + 3.5 µA 7.0 mA/A + 3.5 µA Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-104 by applying known current from multi product calibrator 2.3 mA/A + 35 µA 1.2 mA/A + 35 µA 1.1 mA/A + 35 µA 2.3 mA/A + 35 µA 7.0 mA/A + 35 µA * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 6/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Measuring Instrument AC current (cont.) 0.33 A to < 2.2 A 10 Hz to 45 Hz > 45 Hz to 1 kHz > 1 kHz to 5 kHz 2.2 A to 11 A 45 Hz to 65 Hz > 65 Hz to 500 Hz > 500 Hz to 1 kHz DC Resistance 0 Ω to < 11 Ω 11 Ω to < 33 Ω 33 Ω to < 110 Ω 110 Ω to < 330 Ω 330 Ω to < 1.1 kΩ Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-104 by applying known 2.3 mA/A + 0.35 mA current from multi 1.2 mA/A + 0.35 mA product calibrator 8.7 mA/A + 0.35 mA 0.70 mA/A + 2.4 mA 1.2 mA/A + 2.4 mA 3.9 mA/A + 2.4 mA 0.14 mΩ/Ω + 9.3 mΩ 0.14 mΩ/Ω + 18 mΩ 0.11 mΩ/Ω + 18 mΩ 0.11 mΩ/Ω + 18 mΩ 0.11 mΩ/Ω + 70 mΩ In-house method : CP01-105 by applying known Resistance from multi product calibrator * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 7/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Measuring Instrument DC Resistance (cont.) 1.1 kΩ to < 3.3 kΩ 3.3 kΩ to < 11 kΩ 11 kΩ to < 33 kΩ 33 kΩ to < 110 kΩ 110 kΩ to < 330 kΩ 330 kΩ to < 1.1 MΩ 1.1 MΩ to < 3.3 MΩ 3.3 MΩ to < 11 MΩ 11 MΩ to < 33 MΩ 33 MΩ to < 110 MΩ 110 MΩ to 330 MΩ Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark 0.11 mΩ/Ω + 70 mΩ 0.11 mΩ/Ω + 0.70 Ω 0.11 mΩ/Ω + 0.70 Ω 0.13 mΩ/Ω + 7.0 Ω 0.14 mΩ/Ω + 7.0 Ω 0.18 mΩ/Ω + 64 Ω 0.18 mΩ/Ω + 65 Ω 0.70 mΩ/Ω + 0.64 kΩ 1.2 mΩ/Ω + 0.64 kΩ 5.8 mΩ/Ω + 6.4 kΩ 5.8 mΩ/Ω + 20 kΩ In-house method : CP01-105 by applying known Resistance from multi product calibrator * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 8/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Generating Instrument DC voltage source/ DC voltage calibrator 0 mV to 100 mV > 0.1 V to 1 V > 1 V to 10 V > 10 V to 100 V > 100 V to 1 000 V AC voltage source/ AC voltage calibrator 10 mV to 100 mV 10 Hz to 40 Hz > 40 Hz to 1 kHz > 1 kHz to 20 kHz > 20 kHz to 50 kHz > 50 kHz to 100 kHz Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-201 by direct measurement with 8 ! digits digital multimeter 5.8 µV/V + 1.7 µV 4.7 µV/V + 1.7 µV 4.7 µV/V + 1.8 µV 7.0 µV/V + 35 µV 21 µV/V + 0.14 mV 81 µV/V + 4.8 µV 81 µV/V + 2.5 µV 0.17 mV/V + 2.4 µV 0.35 mV/V + 2.5 µV 0.93 mV/V + 2.5 µV In-house method : CP01-202 by direct measurement with 8 ! digits digital multimeter * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 9/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark Generating Instrument AC voltage source/ AC voltage calibrator 10 mV to 100 mV (cont.) 3.5 mV/V + 12 µV > 100 kHz to 300 kHz 12 mV/V + 13 µV > 300 kHz to 1 MHz > 0.1 V to 1 V 81 µV/V + 47 µV 10 Hz to 40 Hz > 40 Hz to 1 kHz 81 µV/V + 24 µV > 1 kHz to 20 kHz 0.17 mV/V + 24 µV 0.35 mV/V + 24 µV > 20 kHz to 50 kHz > 50 kHz to 100 kHz 0.93 mV/V + 24 µV 3.5 mV/V + 0.12 mV > 100 kHz to 300 kHz 12 mV/V + 0.13 mV > 300 kHz to 1 MHz In-house method : CP01-202 by direct measurement with 8 ! digits digital multimeter * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 10/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Temporary Best Measurement Capability* Standard/Technique/ Method/Equipment/Remark Generating Instrument AC voltage source/ AC voltage calibrator (cont.) > 1 V to 10 V 10 Hz to 40 Hz > 40 Hz to 1 kHz > 1 kHz to 20 kHz > 20 kHz to 50 kHz > 50 kHz to 100 kHz > 100 kHz to 300 kHz > 300 kHz to 1 MHz Mobile In-house method : CP01-202 by direct measurement with 8 ! digits digital multimeter 81 µV/V + 0.47 mV 81 µV/V + 0.24 mV 0.17 mV/V + 0.24 mV 0.35 mV/V + 0.24 mV 0.93 mV/V + 0.24 mV 3.5 mV/V + 1.2 mV 12 mV/V + 1.3 mV * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 11/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Temporary Best Measurement Capability* Standard/Technique/ Method/Equipment/Remark Generating Instrument AC voltage source/ AC voltage calibrator (cont.) > 10 V to 100 V 10 Hz to 40 Hz > 40 Hz to 1 kHz > 1 kHz to 20 kHz > 20 kHz to 50 kHz > 50 kHz to 100 kHz > 100 V to 700 V 40 Hz to 1 kHz Mobile In-house method : CP01-202 by direct measurement with 8 ! digits digital multimeter 0.23 mV/V + 4.7 mV 0.23 mV/V + 2.4 mV 0.23 mV/V + 2.4 mV 0.41 mV/V + 2.4 mV 1.4 mV/V + 2.4 mV 0.47 mV/V + 24 mV * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 12/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Generating Instrument DC current source/ DC current calibrator 0 µA to 100 µA > 0.1 mA to 1 mA > 1 mA to 10 mA > 10 mA to 100 mA > 0.1 A to 1 A AC current source/ AC current calibrator 0.1 mA to 1 mA 10 Hz to 20 Hz > 20 Hz to 45 Hz > 45 Hz to 100 Hz > 100 Hz to 5 kHz Temporary Best Measurement Capability* 23 µA/A + 0.93 nA 23 µA/A + 5.8 nA 23 µA/A + 58 nA 41 µA/A + 0.58 µA 0.13 µA/A + 12 µA Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-203 by direct measurement with 8 ! digits digital multimeter In-house method : CP01-204 by direct measurement with 8 ! 4.7 mA/A + 0.23 µA digits digital multimeter 1.8 mA/A + 0.23 µA 0.70 mA/A + 0.23 µA 0.35 mA/A + 0.23 µA * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 13/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Generating Instrument AC current source/ AC current calibrator 0.1 mA to 1 mA (cont.) > 5 kHz to 10 kHz > 1 mA to 10 mA 10 Hz to 20 Hz > 20 Hz to 45 Hz > 45 Hz to 100 Hz > 100 Hz to 5 kHz > 5 kHz to 10 kHz Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-204 by direct measurement with 8 ! 0.70 mA/A + 0.23 µA digits digital multimeter 4.7 mA/A + 2.3 µA 1.8 mA/A + 2.3 µA 0.70 mA/A + 2.3 µA 0.35 mA/A + 2.3 µA 0.70 mA/A + 2.3 µA * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 14/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Generating Instrument AC current source/ AC current calibrator (cont.) > 10 mA to 100 mA 10 Hz to 20 Hz > 20 Hz to 45 Hz > 45 Hz to 100 Hz > 100 Hz to 5 kHz > 5 kHz to 10 kHz > 0.1 A to 1 A 10 Hz to 20 Hz > 20 Hz to 45 Hz > 45 Hz to 100 Hz Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-204 by direct measurement with 8 ! digits digital multimeter 4.7 mA/A + 23 µA 1.8 mA/A + 23 µA 0.70 mA/A + 23 µA 0.35 mA/A + 23 µA 0.70 mA/A + 23 µA 4.7 mA/A + 0.23 mA 1.9 mA/A + 0.23 mA 0.93 mA/A + 0.23 mA * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 15/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand CALIBRATION 0026 Permanent Site Parameter/Range/Item Generating Instrument AC current source/ AC current calibrator > 0.1 A to 1 A (cont.) > 100 Hz to 5 kHz > 5 kHz to 10 kHz DC Resistance, 4-wire 0 Ω to 10 Ω > 10 Ω to 100 Ω > 0.1 kΩ to 1 kΩ > 1 kΩ to 10 kΩ > 10 kΩ to 100 kΩ > 0.1 MΩ to 1 MΩ > 1 MΩ to 10 MΩ > 10 MΩ to 100 MΩ Temporary Best Measurement Capability* Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-204 by direct measurement with 8 ! 1.2 mA/A + 0.23 mA digits digital multimeter 3.5 mA/A + 0.23 mA 18 µΩ/Ω + 59 µΩ 14 µΩ/Ω + 0.58 mΩ 12 µΩ/Ω + 0.60 mΩ 12 µΩ/Ω + 6.4 mΩ 12 µΩ/Ω + 60 mΩ 18 µΩ/Ω + 2.7 Ω 58 µΩ/Ω + 0.12 kΩ 0.58 mΩ/Ω + 1.2 kΩ In-house method : CP01-205 by direct measurement with 8 ! digits digital multimeter * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Issue No. 4 Page 16/17 Issue Date Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry July 2007 Scope of Accreditation for Calibration Laboratory Name : Test Equipment Calibration Laboratory Aeronautical Radio of Thailand Limited Premises : Accreditation No. : Laboratory Status : CALIBRATION 0026 Permanent Site Temporary Parameter/Range/Item Best Measurement Capability* Generating Instrument DC Resistance, 4-wire (cont.) > 0.1 GΩ to 1 GΩ 5.8 mΩ/Ω + 13 kΩ Field of Measurement Electrical (cont.) 102 Ngamduplee, Tungmahamek, Sathorn, Bangkok, Thailand Mobile Standard/Technique/ Method/Equipment/Remark In-house method : CP01-205 by direct measurement with 8 ! digits digital multimeter * expressed as an uncertainty (+) which for k = 2, providing a level of confidence of approximately 95% Date of Issue : July 2007 Signature : (Issra Shoatburakarn) Deputy Permanent Secretary for Industry Chairman, Ministerial Cluster for Industrial and Entrepreneurial Promotion Chairman of Industrial Product Standards Council Initial Date of Issue 10th October 2001 Page 17/17 Thai Laboratory Accreditation Scheme, Thai Industrial Standards Institute, Ministry of Industry Issue No.4