39584 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection (formerly GE Power Controls), a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from, wholesalers, installers, panel-board builders, contractors, OEMs and utilities worldwide. GE Consumer & Industrial Power Protection Control and Automation For industrial applications ED.03 Contactors and Thermal overload relays Control and Automation @ www.ge.com/ex/powerprotection www.ge.com/eu/powerprotection ED.02 GE INDUSTRIAL BELGIUM POWER PROTECTION Nieuwevaart 51 B-9000 Gent - Belgium Tel. +32/9 265 21 11 Fax +32/9 265 28 00 E-mail: gepcbel@gepc.ge.com GE POWER CONTROLS Ltd 129-135 Camp Road St Albans Herts AL1 5HL United Kingdom Customer Service Tel. 0800 587 1251 Fax 0800 587 1239 gepcuk@gepc.ge.com GE imagination at work GE imagination at work 680804 Ref. C/4551/E/EX 11.0 Ed. 09/07 © Copyright GE Consumer & Industrial 2007 Contactors and overload relays Series M - Minicontactors C.3 Order codes C.23 Technical data C.29 Terminal numbering C.50 Dimensions Series CL - Contactors C.11 Order codes C.31 Technical data C.39 Terminal numbering C.52 Dimensions Series CK - Contactors C.19 Order Codes C.42 Technical data C.58 Dimensions A Plug-in relays and Auxiliary contactors Series MT0 - Thermal overload relays for minicontactors C.61 Order codes C.68 Technical data C.69 Dimensions Motor protection devices B Contactors and Thermal overload relays C Series RT - Thermal overload relays for contactors C.63 Order codes C.70 Technical data C.74 Dimensions Series RE - Electronic overload relays C.66 Order codes C.77 Technical data C.78 Dimensions Order codes C.82 Technical data C.84 Dimensions Series 390.R - Clapper contactors C.87 Order codes C.93 Technical data C.96 Dimensions D Control and signalling units E Electronic relays F Limit switches G Speed drive units H Main switches I Numerical index X NEW Series CSCN - Contactors for capacitors C.81 Motorstarters NEW C.1 Series M Three and four pole minicontactors 6, 9 and 12A (AC3) 20A (AC1) Contactors • Control circuit: Alternating current up to 600V Direct current up to 440V • Terminal numbering in accordance with EN 50012 • Fixing by clipping onto 35 mm DIN rail (EN 50022-35) or by screws • Screws and fast-on terminals protected against accidental contact in accordance with VDE 0106 T.100 and VBG4 • Versions: Ring terminal and printed circuit terminals • Facility to mount instant and timed auxiliary contact blocks and voltage suppressor block • Degree of protection IP20 (EN 60529). • Maximum number of auxiliary contacts to be added: 6 Standards A General data IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 EN 50003 EN 50005 EN 50012 UL 508 NEMA ICS-1 B C D BS 4794 NFC 63-110 CSA C22.2/14 VDE 0660 SEV 10254 JIS C8325 JEM 1038 CENELEC HD 419 MC0... MC1... MC2... 4 4 4 20 20 (A) 20 9 12 (A) 6 Maximum number of poles Rated thermal current (Ith) θ H 60º (1) Rated operational current Ie (2) (3x440V, 50/60Hz, AC3) Rated insulation current Ui Rated operational current Ue (V) (V) 50 7 690 750 690 750 690 Standard voltages Approvals To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (other voltages on request) E Alternating current (V). Bifrequency coil cULus DEMKO NEMKO F © 10 1 2 9 3 4 5 6 7 8 12 13 AC 12 24 42 48 110 120 220 230 240 440 380 400 50/60Hz 115 SEMKO SETI IMQ G Operating voltages limits with bifrequency coils: With 60Hz =0.85 to 1.1 x Us With 50Hz =0.8 to 1.1 x Us in continuous service (ED=100%) with a maximum ambient temperature of 40ºC Alternating current (V). H Lloyd’s Register RINA Bureau Veritas I Order codes Auxiliary contact blocks Accessories Technical data Terminal numbering Dimensions C.2 © A E G K M AC 48 115 50Hz 127 AC 6 32 60 208 60Hz 220 N S U 220 260 380 240 400 240 440 277 W Y 415 500 440 480 600 Direct current (V) CE X ! ! ! ! ! ! pg. C.3 pg. C.6 pg. C.8 pg. C.23 pg. C.29 pg. C.50 © DC A B C D E F G H Direct current (V) - Wide voltage range © DC I J K L N 17 R S 16 6 12 32 24 36 42 48 60 72 110 120 125 220 230 240 250440 WD WE WG WI WJ WN 24 33 48 72 110 220 Series M Three pole minicontactors Terminal: screw 20 6 0.37 0.75 1.5 2.2 0,5 1 2 3 3 4 Control circuit: Alternating current Aux. contacts •3 •1 Cat. no. (1) Pack •4 •2 Control circuit: Direct current Cat. no. (1) Pack Ref. no. see bottom Ref. no. see bottom 1 0 0 1 MC0A310AT © MC0A301AT © 20 20 MC0C310AT © MC0C301AT © 10 10 20 9 0.56 1.12 2.2 4 4 0.75 1.5 3 5.5 5.5 1 0 0 1 MC1A310AT © MC1A301AT © 20 20 MC1C310AT © MC1C301AT © 10 10 20 12 0.75 2 1 2.6 1 0 0 1 MC2A310AT © MC2A301AT © 20 20 MC2C310AT © MC2C301AT © 10 10 1 0 0 1 MC0A310AR © MC0A301AR © 20 20 MC0C310AR © MC0C301AR © 10 10 3 4 5.5 5.5 7.3 7.3 Terminal: ring terminal 0.37 0.75 1.5 2.2 20 6 0.5 1 2 3 3 4 20 9 0.56 1.12 2.2 4 4 0.75 1.5 3 5.5 5.5 1 0 0 1 MC1A310AR © MC1A301AR © 20 20 MC1C310AR © MC1C301AR © 10 10 20 12 0.75 2 1 2.6 1 0 0 1 MC2A310AR © MC2A301AR © 20 20 MC2C310AR © MC2C301AR © 10 10 3 4 5.5 5.5 7.3 7.3 Terminal: faston 2x2.8 insulated (5) 16 (4) 6 0.37 0.75 1.5 2.2 0.5 1 2 3 16 (4) 9 A 3 4 0.56 1.12 2.2 4 4 0.75 1.5 3 5.5 5.5 Terminal: printed circuit 20 6 0.37 0.75 1.5 2.2 0.5 1 2 3 3 4 1 0 0 1 MC0A310AF © MC0A301AF © 20 MC0C310AF © 20 MC0C301AF © 10 10 1 0 0 1 MC1A310AF © MC1A301AF © 20 MC1C310AF © 20 MC1C301AF © 10 10 1 0 0 1 MC0A310AI © MC0A301AI © 20 MC0C310AI © 20 MC0C301AI © 10 10 20 9 0.56 1.12 2.2 4 4 0.75 1.5 3 5.5 5.5 1 0 0 1 MC1A310AI © MC1A301AI © 20 MC1C310AI © 20 MC1C301AI © 10 10 20 12 0.75 2 1 2.6 1 0 0 1 MC2A310AI © MC2A301AI © 20 MC2C310AI © 20 MC2C301AI © 10 10 5.5 5.5 7.3 7.3 B C 3 4 3P and 4P minicontactors Max.operat.current Admissible power AC3 Non1-phase 3-phase Motors inductive <440V, 115V220V 220V380V500V loads 3~ 230V400V 50/60Hz AC1 (2) AC3 (3) kW kW kW kW kW HP HP HP HP HP A A D E Spare coil MB0A © 10 MB0C © 10 F G (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (other voltages on request) (see C.2) (2) Electrical endurance AC-1: MC0... 0.2 x 106 operations MC1... 0.3 x 106 operations MC2... 0.35 x 106 operations (3) Electrical endurance AC-3: MC0... (6A) = 1.2 x 106 operations MC1... (9A) = 0.85 x 106 operations MC2... (12A)= 0.6 x 106 operations (4) Terminal with wire 1.5 mm2: Ie = 16A with wire 1 mm2: Ie = 10A Insulated terminal type B 2.8 x 0.8 and wire 1 mm2 Ie = 8A in accordance with DIN 46247. (5) Fast-on 1 x 6.3 terminals on request (replace letter F by H in the catalogue number) H I X For reference numbers, see chapter X, pg. X.4 C.3 Series M Three pole interface contactors Admissible power AC3 Max. oper. current 1-phase 3-phase NonMotors inductive <440V, 115V220V 220V380V500V load 3~ 230V400V 50/60Hz (3) AC1 AC3 kW kW kW kW kW A A Contactors Terminal: screw 20 6 Aux. contacts •3 •1 •4 •2 Voltage 24V D.C, coil 1.2W (1) (1) Voltage 24V D.C, coil 2W (2) Cat. no. Ref. no. Pack Cat. no. (1) Ref. no. Pack 0.37 0.75 1.5 2.2 3 1 0 0 1 MC0I310ATD 100570 MC0I301ATD 100571 10 10 MC0K310ATD 100574 MC0K301ATD 100575 10 10 20 9 0.56 1.12 2.2 4 4 1 0 0 1 MC1I310ATD 100572 MC1I301ATD 100573 10 10 MC1K310ATD 100576 MC1K301ATD 100577 10 10 20 12 0.75 2 3 5.5 5.5 1 0 0 1 MC2I310ATD 100559 MC2I301ATD 100538 10 10 MC2K310ATD 103590 MC2K301ATD 103591 10 10 Spare coil MB0ID 100470 10 MB0KD (1) No possibility of adding instantaneous auxiliary contact blocks. (2) Facility to mount an instantaneous auxiliary contact block of two contacts or two instantaneous auxiliary contact blocks of one contact. (3) Electrical endurance AC-3: MC0... (6A) = 1.2 x 106 operations. MC1... (9A) = 0.85 x 106 operations. MC2... (12A) = 0.6 x 106 operations. A B C D E F G H I X C.4 100471 10 Series M Four poles minicontactors Poles Screw terminal 20 6 20 9 20 12 AC1 1.8 3.5 6.1 10.5 13.8 - - - - - AC3 0.37 0.75 1.5 2.2 3 0.5 1 2 3 4 AC1 2.3 4.4 7.5 13 17 - - - - - AC3 0.56 1.12 2.2 4 4 0.75 1.5 3 5.5 5.5 AC1 2.3 4.4 7.5 13 17 - - - - - AC3 0.75 2 3 5.5 5.5 1 2.6 4 7.3 7.3 Terminal: faston 2x2.8 insulated (5) 20 6 AC1 1.8 3.5 6.1 10.5 13.8 - - - - - AC3 0.37 0.75 1.5 2.2 3 0.5 1 2 3 4 (4) 16 9 AC1 2.3 4.4 7.5 13 17 - - - - - AC3 0.56 1.12 2.2 4 4 0.75 1.5 3 5.5 5.5 Control circuit: Alternating current Cat. no. (1) Control circuit: Direct current Pack Cat. no. (1) Ref. no. see bottom Pack Ref. no. see bottom 4 2 0 0 2 4 MC0A400AT © MC0AB00AT © MC0AA00AT © 20 20 20 MC0C400AT © MC0CB00AT © 10 10 4 2 0 0 2 4 MC1A400AT © MC1AB00AT © MC1AA00AT © 20 20 20 MC1C400AT © MC1CB00AT © 10 10 4 2 0 2 MC2A400AT © MC2AB00AT © 20 20 MC2C400AT © MC2CB00AT © 10 10 4 2 0 0 2 4 MC0A400AF © MC0AB00AF © MC0AA00AF © 20 20 20 MC0C400AF © MC0CB00AF © 3P and 4P minicontactors Admissible power AC3 Max.oper.current 1-phase 3-phase NonMotors inductive <440V, 115V220V 220V380V500V load 3~ 230V400V 50/60Hz (2) (3) AC1 AC3 kW kW kW kW kW HP HP HP HP HP A A A 10 10 B 4 2 0 0 2 4 MC1A400AF © MC1AB00AF © MC1AA00AF © 20 20 20 MC1C400AF © MC1CB00AF © 10 10 C D Terminal: printed circuit 20 6 AC1 1.8 3.5 6.1 10.5 13.8 - - - - - AC3 0.37 0.75 1.5 2.2 3 0.5 1 2 3 4 20 9 AC1 2.3 4.4 7.5 13 17 - - - - - AC3 0.56 1.12 2.2 4 4 0.75 1.5 3 5.5 5.5 Spare coil 4 2 0 0 2 4 MC0A400AI © 20 MC0C400AI © 10 MC0AB00AI © 20 MC0CB00AI © 10 MC0AA00AI © 20 4 2 0 0 2 4 MC1A400AI © MC1AB00AI © MC1AA00AI © 20 20 20 E F MC1C400AI © 10 MC1CB00AI © 10 G MB0A © 10 MB0C © 10 H I (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see C.2) (2) Electrical endurance AC-1: MC0... 0.2 x 106 operations MC1... 0.3 x 106 operations MC2... 0.35 x 106 operations (3) Electrical endurance AC-3: MC0... (6A) = 1.2 x 106 operations MC1... (9A) = 0.85 x 106 operations MC2... (12A)= 0.6 x 106 operations (4) Terminal with wire 1.5 mm2: Ie = 16A with wire 1 mm2: Ie = 10A Insulated terminal type B 2.8 x 0.8 and wire of 1 mm2 Ie = 8A in accordance with DIN 46247. (5) Faston 1 x 6.3 terminals on request, (replace letter F by H in the catalogue number). X For reference numbers, see chapter X, pg. X.4 C.5 Series M Instantaneous auxiliary contact blocks Number contacts Front mounting Combinations with basic contactor Contacts in acc. with EN 50012 Contacts in acc.with EN 50005 10E Aux.contacts Cat. no. Ref. no. Pack •3 •1 •4 •2 • Two or four additional contacts, to cover combinations of 3 or 5 contacts without increasing the surface are of the basic contactor Contactors Screw terminal 2 A B C D E F G H I X C.6 21E 11 2 12E 02 2 20 2 11 2 02 1 0 2 1 0 1 2 0 1 2 MACN211AT MACN202AT MARN220AT MARN211AT MARN202AT 100999 100998 100994 100993 100992 10 10 10 10 10 4 41E 31 4 32E 22 4 23E 13 4 40 4 31 4 22 4 13 4 04 3 2 1 4 3 2 1 0 1 2 3 0 1 2 3 4 MACN431AT MACN422AT MACN413AT MARN440AT MARN431AT MARN422AT MARN413AT MARN404AT 100997 100996 100995 100991 100990 100989 100988 100987 10 10 10 10 10 10 10 10 Ring terminal 2 21E 11 2 12E 02 2 20 2 11 2 02 1 0 2 1 0 1 2 0 1 2 MACN211AR MACN202AR MARN220AR MARN211AR MARN202AR 103557 103558 103349 103350 103351 10 10 10 10 10 3 2 1 4 3 2 1 0 1 2 3 0 1 2 3 4 MACN431AR MACN422AR MACN413AR MARN440AR MARN431AR MARN422AR MARN413AR MARN404AR 103559 103560 103561 103352 103353 103354 103355 103300 10 10 10 10 10 10 10 10 4 41E 31 4 32E 22 4 23E 13 4 40 4 31 4 22 4 13 4 04 Series M Instantaneous auxiliary contact blocks Number contacts Lateral mounting Combinations with basic contactor Contacts in acc. with EN 50012 Contacts Aux.contacts in acc.with •3 •1 EN 50005 Cat. no. Ref. no. Pack 10E Screw terminal 1 1 Ring terminal 1 1 20 11E 10 01 1 0 0 1 MACL110AT 100560 MACL101AT 100561 10 10 20 11E 10 01 1 0 0 1 MACL110AR 103555 MACL101AR 103556 10 10 10 01 1 0 0 1 MACL110AF 100562 MACL101AF 100563 10 10 10 01 1 0 0 1 MACL110AI 100564 MACL101AI 100565 10 10 Terminal: faston 2x2.8 insulated (1) 1 20 1 11E Terminal: printed circuit 1 1 20 11E 3P and 4P minicontactors •4 •2 • One or two additional blocks, to cover combinations of 1 or 2 contacts without increasing the height of the basic unit contactor A • One or two additional blocks, when up to 6 or 7 contacts are needed (combination possible with frontal blocks) • One or two additional blocks on both sides, to cover up to five contacts (combination possible only with lateral blocks) B Screw terminal 1 1 10 01 1 0 0 1 MARL110ATS 100519 MARL101ATS 100520 10 10 Ring terminal 1 1 10 01 1 0 0 1 MARL110ARS 103299 MARL101ARS 103298 10 10 C D Terminal: faston 2x2.8 insulated (1) 1 1 10 01 1 0 0 1 MARL110AFS 100521 MARL101AFS 100522 10 10 Terminal: printed circuit 1 1 10 01 1 0 0 1 MARL110AIS 100523 MARL101AIS 100524 10 10 E F G (1) Terminal with wire 1 mm2: Ie = 10A Insulated terminal type B 2.8 x 0.8 with wire 1 mm2: Ie = 8A, in accordance with DIN 46247 H I X C.7 Series M Accessories Electronic timer block Contactors DIN rail adaptor for electronic timer block Voltage suppressor block For use Time Function with: Lateral or front fixing to the contactor MCR..MC_ ... 0.5 - 60 seg. delay ON MCR..MC_ ... 0.2 - 24 seg. delay ON For fixing onto EN 50022-35 MREBC... For use Type with: Connection and (plug-in) fixing on to the connector MCRA,MC_ ... R/C MCRA,MC_ ... R/C Diode MCRC,MC_ ... MCRC,MC_ ... Varistor Ue Cat. no. Ref. no. Pack 24... 250V AC/DC 24...250V AC/DC MREBC10AC2 MREBC20AC2 100541 100542 10 10 MVB0R 100543 10 Control Ue Cat. no. Ref. no. Pack MP0AAE1 MP0AAE2 MP0CAE3 MP0DAE4 100544 100545 100546 100536 10 10 10 10 Cat. no. Ref. no. Pack MVP0C 100600 10 Cat. no. Ref. no. Pack AC AC DC AC/DC 12...60V 50/60Hz 72...250V 50/60Hz 6...250V DC 24-48V A B Pole paralleling links C For use Phases Terminal Ue with: capacity To connect two, three or four phases in parallel MC_ ... 2, 3, 4 (parallel) Ø4.5mm - 16mm2 For use with: Mechanical interlock and pole jumpers MCR, MC_ ... D E Mechanical interlock F MMH0 100547 10 Cat. no. Ref. no. Pack G H Identification I X C.8 For use with: MCR, MC_ ... MCR, MC_ ... Labels (10 sheets of 260 labels) Labelling plate base. Plug-in labelling plate bases (50 pieces in one pack) EAT 260 SPR 100548 1 100549 1 Series M Multipack. Series M and Series CL To reduce the amount of waste packaging material and to save time during installation, we offer the opportunity to order contactors in a multipack without the individual packaging. Multipack (1) 40 40 20 How to order To order a multipack, add the suffix MP to the standard catalogue number Example Standard pack MC0A310ATN CL03A400MJ Multipack MC0A310ATN MP (40 pieces) CL03A400MJ MP (20 pieces) 3P and 4P minicontactors Product Type Standard pack Minicontactors MC0A...MC2A 20 Contactors CL00A...CL25A... 20 CL03...CL45... 10 (1) The quantity ordered must be a multiple of the quantity in each multipack ( with the same frame/size and coil voltage) A B C D E F G H I X C.9 Series CL Three and four pole contactors 9 to 105A (AC3) 25 to 140A (AC1) Contactors • Control circuit: Alternating current up to 690V Direct current up to 440V • Terminal numbering in accordance with EN 50005 and EN 50012 • Fixing by clipping onto 35mm DIN rail EN 50022-35 or by screws • Screws protected against accidental contact in accordance with VDE 0106 T.100, VBG4. • Ring terminal version • Three coil terminals • Mounting possibilities of front/side instantaneous auxiliary contact blocks, timed auxiliary contact blocks, mechanical latch, transient suppressor block and interface modules. • Degree of protection: IP20 to CL00 ... CL02 IP10 to CL25 ... CL10 • Maximum number of auxiliary contacts: 4 for CL00 ... CL25 6 for CL04 ... CL45 8 for CL06 ... CL10 A Standard voltages Standards C IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 EN 50005 UL 508 NEMA ICS 1 BS 5424 & 775 D Approvals B CSA 22.2/14 NFC 63-110 ASE 1025 VDE 0660/102 CENELEC HD 419 To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit. Alternating current (V). Dual-frequency coil © 1 2 9 3 4 5 6 7 13 8 15 AC 24 42 48 110120220230240400440480 50/60Hz 115 Alternating current (V). E © E K L N T U W Y Z AC 32 127 220 380415500660 50Hz 230 400 690 AC 208277380480460600 60Hz cULus SETI IMQ (hasta Ith=32A) Direct current (V) F For contactors type CL...D / Operating limits: 0.80 ... 1.10 x Us G Lloyd’s Register RINA Bureau Veritas I X C.10 B D E F G H I J K N P R T X Coil with electronic module for contactors CL...E (can also be used with alternating current) H © Voltage 12 24 36 42 48 60 72 110120220230240250440 125 © D F H J N Y Voltage 24 42 60 110220440 28 48 72 125250 Direct current (V). Coil with wide voltage range (0.70 ... 1.30 x Us) CE For contactors type CL...D Order codes Auxiliary contact blocks Accessories Technical data Terminal numbering Dimensions ! ! ! ! ! ! pg. C.11 pg. C.15 pg. C.16 pg. C.31 pg. C.39 pg. C.52 © DC WBWDWE WFWGWH WI WJ WKWNWP WR WT WX Maximun number of add-on 12 24 33 42 48 60 72 110125220230240250440 Coil with electronic module for contactors CL...E © WDWE WFWH WJWN Voltage 24 33 48 72 110220 auxiliary contact blocks: CL00D...CL02D : 2NO or 1NC CL03D...CL45D : 1NO and 1NC CL05D...CL10D : 4NO or 2NC CL05E...CL10E : 4 cont. aux. Different auxiliary contact configurations, contact us. Series CL Three pole contactors. Screw terminal Max.oper.current Motors Noninductive <440V, 3~ load 50/60Hz AC3 AC1 A A 25 9 Spare coils 25 32 45 45 60 60 90 110 12 18 25 25 32 40 50 65 2.2 4 4 5.5 2x106 3 5.5 5.5 7.5 0 1 0 0 0 1 3 5.5 5.5 7.5 2x106 4 7.5 7.5 10 0 1 0 4 7.5 7.5 10 1.7x106 5.5 10 10 13.5 CL00A300T© CL00A310T© CL00A301T© 5 5 5 0 0 1 CL01A300T© CL01A310T© CL01A301T© 0 1 0 0 0 1 7.5 11 11 15 1.2x106 0 10 15 15 20 0 7.5 12 12 15 2x106 10 16 16 20 0 1 0 0 0 1 9 16 16 18.5 2x106 12 22 22 25 0 1 0 25 2x106 34 CL00D310T© CL00D301T© 10 10 5 5 5 CL01D310T© CL01D301T© 10 10 CL02A300T© CL02A310T© CL02A301T© 5 5 5 CL02D310T© CL02D301T© 10 10 CL25A300T© 5 CL25D300T© 10 CL03A300M© CL03A310M© CL03A301M© 10 10 10 CL03D310M© CL03D301M© 10 10 0 0 1 CL04A300M© CL04A310M© CL04A301M© 10 10 10 CL04D310M© CL04D301M© 10 10 0 1 0 1 CL45A300M© CL45A311M© 10 10 CL45D300M© 10 (2) 15 22 25 30 1.8x106 20 30 34 40 0 1 0 1 CL06A300M© CL06A311M© 1 1 CL06D300M© 1 CL06E300M© 1 (2) 18.5 30 37 40 1.7x106 25 40 50 55 0 1 0 1 CL07A300M© 1 CL07A311M© (2) 1 CL07D300M© 1 CL07E300M© 1 11 18.5 22 15 25 30 3P and 4P contactors Control circuit: Control circuit: Control circuit: Admissible power Electrical Aux. Alternating Direct current Coil with electronic endurance contacts AC3 current module (AC/DC) 220V380V415V500V 230V400V440V ••33 •1•1 Cat. no. (1) Cat. Pack Cat. no. (1) Pack Cat. no. (1) Pack (3) (3) (3) AC3 kW kW kW kW HP HP HP HP Operations ••44 • 2• 2 Ref. no. see bottom Ref. no. see bottom Ref. no. see bottom A C 110 80 22 30 45 1.5x10 60 0 1 0 1 CL08A300M© 1 CL08A311M© (2) 1 CL08D300M© 1 CL08E300M© 1 140 95 25 45 50 55 1.7x106 34 60 68 75 0 1 0 1 CL09A300M© 1 CL09A311M© (2) 1 CL09D300M© 1 CL09E300M© 1 140 105 30 55 55 65 1.5x106 0 40 75 75 88 1 0 1 CL10A300M© CL10A311M© CL10D300M© 1 CL10E300M© 1 37 50 45 60 6 B D CL00 - CL25 CL03 - CL45 CL06 - CL10 coil + electronic module CL06E - CL10E LB1A © LB3A © LB4A © (2) 1 1 5 5 5 E F LB1D © LB3D © LB4D © 5 5 1 LB4E © 1 G H (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see C.10). (2) Equipped with two blocks BCLF (3) Multipack, see C.9 I X For reference numbers, see chapter X, pg. X.6 C.11 Series CL Three pole contactors. Ring terminal Contactors B 25 25 32 9 12 18 Control circuit: Direct current Cat. no. (1) Pack (2) Ref. no. see bottom 3 5.5 5.5 7.5 2x106 4 7.5 7.5 10 0 1 0 0 CL01A300R© 0 CL01A310R© 1 CL01A301R© 5 5 5 CL01D310R© CL01D301R© 10 10 4 7.5 7.5 10 1.7x106 5.5 10 10 13.5 0 1 0 0 CL02A300R© 0 CL02A310R© 1 CL02A301R© 5 5 5 CL02D310R© CL02D301R© 10 10 1.2x106 0 0 CL25A300R© 5 CL25D300R© 10 7.5 10 45 25 7.5 12 12 15 2x106 10 16 16 20 0 1 0 0 CL03A300R© 0 CL03A310R© 1 CL03A301R© 10 10 10 CL03D310R© CL03D301R© 10 10 9 16 16 18.5 2x106 12 22 22 25 0 1 0 0 CL04A300R© 0 CL04A310R© 1 CL04A301R© 10 10 10 CL04D310R© CL04D301R© 10 10 60 32 11 15 11 15 15 20 60 40 11 18.5 22 15 25 30 0 25 2x106 34 0 CL45A300R© 10 CL45D300R© 10 90 50 15 22 25 30 1.8x106 0 20 30 34 40 0 CL06A300R© 1 CL06D300R© 1 110 65 18.5 30 37 40 1.7x106 0 25 40 50 55 0 CL07A300R© 1 CL07D300R© 1 110 80 22 37 45 45 1.5x106 0 30 50 60 60 0 CL08A300R© 1 CL08D300R© 1 140 95 25 45 50 55 1.7x106 0 34 60 68 75 0 CL09A300R© 1 CL09D300R© 1 140 105 30 55 55 65 1.5x106 0 40 75 75 88 0 CL10A300R© 1 CL10D300R© 1 Spare coils G 10 10 25 D F CL00D310R© CL00D301R© 45 C E Control circuit: Admissible power Electrical Aux. Alternating AC3 endurance contacts current 220V380V415V500V 230V400V440V •1•1 Cat. no. (1) Pack Cat. ••33 (2) AC3 kW kW kW kW HP HP HP HP Operations ••44 • 2• 2 Ref. no. see bottom 2.2 4 4 5.5 2x106 0 0 CL00A300R© 5 3 5.5 5.5 7.5 1 0 CL00A310R© 5 0 1 CL00A301R© 5 A Max.oper.current Motors Noninductive <440V, load 3~ 50/60Hz AC1 AC3 A A CL00 - CL25 CL03 - CL45 CL06 - CL10 LB1A © LB3A © LB4A © 5 5 5 LB1D © LB3D © LB4D © 5 5 1 H I (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see C.10). (2) Multipack, see C.9 X For reference numbers, see chapter X, pg. X.6 C.12 Series CL Four pole contactors. Screw terminal Admissible power Electrical Power Max.oper.current endurance contacts AC1 Noninductive 220V380V415V500V loads 230V400V440V Cat. AC1 AC1 AC3 kW kW kW kW Operations A A 25 12 9.5 16.5 18 21.5 1.5x106 4 0 32 18 12 22 23 27.5 1.5x106 45 25 17 29 32 39 60 32 22.5 39.5 43 90 50 34 110 65 140 95 Pack Cat. no. (1) (2) Ref. no. see bottom Pack (2) CL01A400T© 5 CL01D400T© 10 0 CL02A400T© 5 CL02D400T© 10 2x106 4 0 CL03A400M© 10 CL03D400M© 10 52 1.5x106 4 0 CL04A400M© 10 CL04D400M© 10 78 1.5x106 4 0 CL05A400M© 1 CL05D400M© 1 42 72.5 79 95 1.8x106 53 92 100 121 1.8x106 4 0 CL07A400M© 1 CL07D400M© 1 4 0 CL09A400M© 1 CL09D400M© 1 59 64 Admissible power AC3 NonMotors inductive <440V, 220V380V415V500V loads 3~ 230V400V440V 50/60Hz AC3 kW kW kW kW AC1 A HP HP HP HP Control circuit: Alternating current Power contacts Cat. no. (1) Control circuit: Coil with electronic module (AC/DC) Cat. no. (1) Ref. no. see bottom 4 Max.oper.current Control circuit: Direct current Cat. no. (1) Pack (2) Pack (2) Ref. no. see bottom CL05E400M© 1 CL07E400M© 1 CL09E400M© 1 Control circuit: Coil with electronic module (AC/DC) Cat. no. (1) Pack (2) Pack 25 12 3 4 5.5 5.5 7.5 7.5 7.5 10 2 2 Ref. no. see bottom CL01AB00T© 5 Ref. no. see bottom CL01DB00T© 5 32 18 4 7.5 7.5 10 5.5 10 10 13.5 2 2 CL02AB00T© 5 CL02DB00T© 5 45 25 7.5 10 12 16 12 16 15 20 2 2 CL03AB00M© 10 CL03DB00M© 10 60 32 9 12 16 22 16 18.5 22 25 2 2 CL04AB00M© 10 CL04DB00M© 10 90 40 11 18.5 22 15 25 30 25 34 2 2 CL05AB00M© 1 CL05DB00M© 1 CL05EB00M© 1 110 65 18.5 30 25 40 37 50 40 55 2 2 CL07AB00M© 1 CL07DB00M© 1 CL07EB00M© 1 110 80 22 30 45 60 45 60 2 2 CL08AB00M© 1 CL08DB00M© 1 CL08EB00M© 1 37 50 CL00 - CL25 CL03 - CL45 CL05A - CL08A Coil + Electronic module CL05E - CL08E LB1A © LB3A © LB4A © LB4E © 5 5 5 1 LB1D © LB3D © LB4D © Ref. no. see bottom B C D E F 5 5 1 A (2) Spare coils Cat. no. (1) Control circuit: Direct current 3P and 4P contactors Control circuit: Alternating current G LB4E © 1 H I (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see C.10). (2) Multipack, see C.9 X For reference numbers, see chapter X, pg. X.6 C.13 Series CL Four poles. Ring terminal Contactors Control circuit: Max.oper.current Admissible power Electrical Power Alternating AC1 endurance contacts Noncurrent inductive 220V380V415V500V load 230V400V440V Cat. Pack Cat. no. (1) (2) AC1 AC1 AC3 kW kW kW kW Operations A A Ref. no. see bottom 9.5 16.5 18 21.5 1.5x106 4 0 CL01A400R© 5 25 12 C Spare coils Ref. no. see bottom CL01D400R© 10 CL02D400R© 10 2x106 4 0 CL03A400R© 10 CL03D400R© 10 52 1.5x106 4 0 CL04A400R© 10 CL04D400R© 10 78 1.5x106 4 0 CL05A400R© 1 CL05D400R© 1 42 72.5 79 95 1.8x106 53 92 100 121 1.8x106 4 0 CL07A400R© 1 CL07D400R© 1 4 0 CL09A400R© 1 CL09D400R© 1 12 22 23 27.5 1.5x106 45 25 17 29 32 39 60 32 22.5 39.5 43 90 50 34 110 65 140 95 59 64 Control circuit: Alternating current Power contacts Admissible power AC3 220V380V415V500V 230V400V440V Cat. no. (1) kW kW kW kW HP HP HP HP Control circuit: Direct current Pack (2) Cat. no. (1) Pack (2) 25 12 3 4 5.5 5.5 7.5 7,5 7,5 10 2 2 Ref. no. see bottom CL01AB00R© 5 32 18 4 7.5 7.5 10 5.5 10 10 13.5 2 2 CL02AB00R© 5 CL02DB00R© 5 45 25 7.5 10 12 16 12 16 15 20 2 2 CL03AB00R© 10 CL03DB00R© 10 60 32 9 12 16 22 16 18.5 22 25 2 2 CL04AB00R© 10 CL04DB00R© 10 D E (2) CL02A400R© 5 18 B Pack 0 32 A Cat. no. (1) 4 Max.oper.current NonMotors inductive <440V, load 3~ 50/60Hz AC1 AC3 A A Control circuit: Direct current CL00 - CL25 CL03 - CL45 CL05A - CL08A LR1A © LR3A © LR4A © 5 5 5 Ref. no. see bottom CL01DB00R© 5 LR1D © LR3D © LR4D © 5 5 1 F G H (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see C.10). (2) Multipack, see C.9 I X For reference numbers, see chapter X, pg. X.6 C.14 Series CL Auxiliary contact blocks Instantaneous Number Contacts of contacts • 3• 3 ••11 • 7 • 7 •5 •5 • 4• 4 Frontal mounting Terminal: screw 2 2 2 1 2 2 2 0 1 Time Cat. no. Ref. no. Pack • 8 • 8 • 6• 6 0 0 1 0 0 0 0 1 BCLF10 BCLF01 BCLF10G BCLF01G 104700 104701 104702 104703 10 10 10 10 0 0 0 0 BCRF10 BCRF01 108901 108902 10 10 0 0 0 0 BCLL20 BCLL11 104706 104707 10 10 For combinations of more than 4 front-mounted and 2 side-mounted auxiliary contact blocks 2 0 0 0 BRLL20 104704 10 1 1 0 0 BRLL11 104705 10 0 2 0 0 BRLL02 106622 10 A Pneumatic timer Front mounting 3P and 4P contactors Side mounting ••22 Terminal: screw 1 1 0 1 0 1 1 0 0 1 0 0 Terminal: ring terminal 1 1 0 1 0 1 Type Terminal: screw 2 0 2 0 2 0 2 0 0 0 0 0 1 1 1 1 1 1 1 1 Delay ON Delay ON Delay OFF Delay OFF 0.1 - 30 sec. 1 - 60 sec. 0.1 - 30 sec. 1 - 60 sec. BTLF30C BTLF60C BTLF30D BTLF60D 104709 104710 104711 104712 10 10 10 10 Terminal: ring terminal 2 0 0 2 0 0 2 0 0 2 0 0 1 1 1 1 1 1 1 1 Delay ON Delay ON Delay OFF Delay OFF 0.1 - 30 sec. 1 - 60 sec. 0.1 - 30 sec. 1 - 60 sec. BTRF30C BTRF60C BTRF30D BTRF60D 108903 108904 108905 108906 10 10 10 10 BTLFX 113001 5 Seaking cover protection for pneumatic timer B C D E Accessories Interlock Cat. no. (1) Ref. no. Number Contacts of contacts •3 •1 • 7 •5 •4 •2 •8 •6 - - - CL00 ... CL10 BELA 104723 5 2 - - CL00 ... CL10 BELA02 104724 5 SBELA 101017 5 Mechanical - - Mech./ electrical 2 0 Support interlock Only for direct current contactors For use with: Pack F G CL00D...CL10D H I Mechanical latch blocks Frontal mounted to the contactor CL00 ... CL10 RMLF © see bottom 10 X © D G HC J N U Y 50Hz 24, 32 42, 48 110, 115, 120, 127 220, 230, 240 380, 400, 415, 440, 480 500, 660/690 60HZ 24, 32 48, 60 110, 115, 120, 127 208, 220, 240, 277 380, 400, 415, 440, 480 600 DC24, 32, 36 42, 48 60, 72 110, 120, 125 220, 230, 240, 250 440 1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see C.10). For reference numbers, see chapter X, pg. X.6 C.15 Series CL Accessories Contactors Transient voltage suppressor block A B C D E F G H I X C.16 For use with: Type Control circuit Ue Cat. no. Ref. no. Fixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks. CL00 ... CL45 R/C AC 12V ... 48V BSLR2G CL00 ... CL45 R/C AC 50V ... 127V BSLR2K CL00 ... CL45 R/C AC 130V ... 250V BSLR2R 104713 104714 104715 10 10 10 CL05A ... CL10A CL05A ... CL10A CL05A ... CL10A R/C R/C R/C AC AC AC 12V ... 48V 50V ... 127V 130V ... 250V BSLR3G BSLR3K BSLR3R 104716 104717 104718 10 10 10 CL_ _ D Diode DC 12V ... 600V BSLDZ 104719 10 CL00 ... CL10 CL00 ... CL10 CL00 ... CL10 CL00 ... CL10 Varistor Varistor Varistor Varistor AC / DC AC / DC AC / DC AC / DC 24V ... 48V 50V ... 127V 130V ... 250V 277V ... 500V BSLV3G BSLV3K BSLV3R BSLV3U 104720 104721 104722 110836 10 10 10 10 Electronic timer module Pack Cat. no. Ref. no. For use Control circ. Type Time with: Fixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks. CL00 ... CL10 24-250V AC/DC delay ON 0.1 - 2 sec. BETL02C 113602 CL00 ... CL10 24-250V AC/DC delay ON 1.5 - 45 sec. BETL45C 113603 CL00 ... CL10 CL00 ... CL10 24-250V AC/DC 24-250V AC/DC delay OFF delay OFF 0.1 - 2 sec. 1.5 - 45 sec. BETL02D BETL45D 113604 113605 Pack 5 5 5 5 Series CL Accessories Identification For use with: CL00 ... CL10 CL00 ... CL10 Cat. no. Ref. no. Pack Sheets of labels (sheets of 260 labels each) Labelling plate base (50 pieces in one pack) EAT 260 SPR 100548 100549 1 1 PTP04 PTP45 PTP08 PTP10 113850 113851 113852 113853 8 6 8 8 CL03 ... CL04 CL45 CL05 ... CL08 CL09 ... CL10 Spares Contact kits Cat. no. Ref. no. Pack For use with: Number of sets Type CL00_ _ _ 3 NO V31200B 104738 1 CL01_3_/CL01_4_ CL01_B_ 3 4 NO 2NO-2NC V31201B VB1201B 104739 104740 1 1 CL02_3_/CL02_4_ CL02_B_ 3 4 NO 2NO-2NC V31202B VB1202B 104741 104742 1 1 CL25_3_ 3 NO V31225B 104757 1 CL03_3_/CL03_4_ CL03_B_ 3 4 NO 2NAO-2NC V31203B VB1203B 104743 133170 1 1 CL04_3_/CL04_4_ CL04_B_ 3 4 NO 2NO-2NC V31204B VB1204B 104745 133885 1 1 CL45_3_ 3 NO V31245B 104758 1 CL05_4_ CL05_B_ 4 4 NO 2NO-2NC V31205B VB1205B 104747 104748 1 1 CL06_ _ _ 3 NO V31206B 104749 1 CL07_3_/CL07_4_ CL07_B_ 3 4 NO 2NO-2NC V31207B VB1207B 104750 104751 1 1 CL08_3_/CL08_4_ CL08_B_ 3 4 NO 2NO-2NC V31208B VB1208B 104752 104753 1 1 CL09_ _ _ 3 NO V31209B 104754 1 CL10_ _ _ 3 NO V31210B 104755 1 3P and 4P contactors Pole terminal protector IPXXB A B C D E F G H I X C.17 Series CK Three and four pole contactors 150 to 825A (AC3) 200 to 1250A (AC1) Contactors • Control circuit: Alternating current up to 690V Direct current up to 500V • Degree of protection IP00 (IPxxB with accessories) • CK07...CK13: auxiliary and coil terminals originally protected against accidental contacts. Protection for power contacts on request (see accessories) • Terminals protected against accidental contacts according to VDE 0106 T.100, VBG4. • CK_ _E_with electronic module suitable for DC and AC. (50/60Hz) • CK contactors always provided with one auxiliary contact block BCLL11 (1NO+1NC) A B C Standards IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 EN 50005 UL 508 NEMA ICS 1 BS 5424 & 775 Standard voltages CSA 22.2/14 CENELEC HD 419 NFC 63-110 ASE 1025 UNE 20109 VDE 0660/102 To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit. Alternating current (V) Three-pole contactors: Four-pole contactors: © C D F CK75CA3..., CK08CA3..., CK85BA3... CK07BA4..., CK08BA4... G H I J K M N R S T U V W X Y Z 50Hz 24 42 48 110127 220240 380 415440500660 230 400 690 D Approvals 60Hz 24 (1) 48 110120 220277 240380480440 600 Alternating current (V). Dual-frequency coil Three-pole contactors: Four-pole contactors: E cULus CE © 1 2 CK75CA3..., CK08CA3..., CK85BA3... CK07BA4..., CK08BA4... 3 6 13 50/60Hz 24 48 110 230 400 F Alternating current (V) G Lloyd’s Register Bureau Veritas RINA Three-pole contactors: Four-pole contactors: © J N U CK13BA3... CK13BA4... Y Z 50/60Hz 110220380480600 240440500660 H Control circuit with rectifier bridge © J N U 50Hz 110220380 230400 60Hz 120240480 Direct current (V). With electronic module (0.7 ... 1.3 x Us) Three-pole contactors: CK75CE3...., CK08CE3..... I © WDWE WFWH WJWN Voltage 24 33 48 72 110220 X Alternating c. / Direct c. (V). With electronic module (0.8 ... 1.10 x Us) Three-pole & four-pole contactors: CK ....... E...... Order codes ! Aux. contact blocks ! Accessories & Spares ! Technical data ! Dimensions ! C.18 pg. C.19 pg. C.20 pg. C.21 pg. C.42 pg. C.58 © D F J N U Y Voltage 24 42 110220380440 28 48 127250415500 (1) CK13 not UL Series CK Three pole contactors Max.oper.current Admissible power AC3 Electrical endurance Control circuit: Alternating current Control circuit: A.C. / D.C. Cat. AC3 Operations Pack Cat. no. (1) Ref. no. see bottom Pack Cat. no. (1) Ref. no. see bottom 250 150 45 75 80 80 100 60 100 108 108 135 1.7x106 CK75CA311 © 1 CK75CE311 © 1 250 185 55 90 100 100 110 75 125 135 135 150 1.2x106 CK08CA311 © 1 CK08CE311 © 1 315 205 65 110 125 125 132 88 150 170 170 180 1.7x106 CK85BA311 © 1 CK85BE311 © 1 315 250 75 132 132 132 160 100 180 180 180 220 1.5x106 CK09BE311 © 1 450 309 90 160 160 185 200 125 220 220 250 270 1,1x106 CK95BE311 © 1 600 420 125 220 230 230 300 170 300 312 312 405 1x106 CK10CE311 © 1 700 550 160 280 315 315 400 220 380 425 425 540 0.8x106 CK11CE311 © 1 1000 700 220 375 400 425 480 300 510 540 650 0.7x106 CK12BE311 © 1 1250 825 250 450 450 450 500 340 610 610 610 680 0.7x106 (2) CK13BA311 © 220V380V415V440V500V 230V400V440V kW kW kW kW kW HP HP HP HP HP Spare coil CK75CA3 ... CK08CA3 CK85BA3 CK13BA3 Control circuit with incorporated rectifier bridge CK13BA3 Coil Electronic module CK75CE3 ... CK08CE3 CK85BE3 ... CK95BE3 CK12BE3 CK10CE3 ... CK11CE3 CK75CE3 ... CK08CE3 CK85BE3 ... CK95BE3 CK12BE3 CK10CE3 ... CK11CE3 A 1 3P and 4P contactors AC1 A Motors <440V, 3~ 50/60Hz AC3 A Noninductive loads C12168 © C04255 © C08998 © C09120 © 1 1 1 1 B C KB4E © KB5E © KB6E © KB7E © KM4E © KM5E © KM6E © KM7E © 1 1 1 1 1 1 1 1 (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see C.18). (2) CK13 non alow the aux. block in right side. D E F G H I X For reference numbers, see chapter X, pg. X.7 C.19 Series CK Four pole contactors Max.oper. current Control circuit: Control circuit: Electrical Alternating A.C. / D.C. endurance AC1 current 220V380V415V440V500V 230V400V Pack Cat. no. (1) Pack Cat. no. (1) Cat. AC3 kW kW kW kW kW Operations Ref. no. see bottom Ref. no. see bottom CK07BE411 © 1 CK07BA41 © 1 105 76 131 143 151 173 1x106 Admissible power AC3 380V Noninductive 400V loads AC1 kW A A Contactors 200 55 325 100 185 123 214 233 247 281 0.6x106 400 132 250 152 263 287 304 346 500 600 CK08BE411 © 1 0.6x106 CK09BE411 © 1 160 309 191 329 359 380 415 0.6x106 CK95BE411 © 1 220 408 228 395 431 456 519 0.5x106 CK10CE411 © 1 700 280 530 266 460 503 533 606 0.4x106 CK11CE411 © 1 1000 375 680 381 658 719 762 866 0.4x106 CK12BE411 © 1 1250 450 800 476 822 898 952 1082 0.6x106 (2) CK13BA411 © Spare coil B CK07BA4 CK08BA4 CK13BA4 Control circuit with incorporated rectifier bridge CK13BA4 Coil Electronic module C 1 C04255 © C04787 © C08998 © C09120 © 1 1 1 1 CK07BE4 CK08BE4 ... CK95BE4, CK12BE4 CK10CE4 ... CK11CE4 CK07BE4 CK08BE4 ... CK95BE4, CK12BE4 CK10CE4 ... CK11CE4 D KB5E © KB6E © KB7E © KM5E © KM6E © KM7E © 1 1 1 1 1 1 (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see C.18). (2) CK13 non alow the aux. block in right side. E F Auxiliary instantaneous contact block Number of G Side mounting I 1 A H CK08BA411 © Contacts contacts 3 • •1 • 7 •5 •4 •6 •2 •8 2 2 0 0 0 2 1 1 0 0 combinations of more than 2 blocks 2 2 0 0 0 2 1 1 0 0 2 0 2 0 0 Cat. no. Ref. no. Pack BCLL20 BCLL11 104706 104707 10 10 BRLL20 BRLL11 BRLL02 104704 104705 106622 10 10 10 X For reference numbers, see chapter X, pg. X.9 C.20 Series CK Accessories For use with: Transient voltage suppressor Voltage Ue Cat. no. F ixation to the coil terminals, that allows simultaneous use with the auxiliary contact blocks. CK75 ... CK08 AC 24V - 48V BSLR3G CK75 ... CK08 AC 50V - 127V BSLR3K CK75 ... CK08 AC 130V - 240V BSLR3R CK75 ... CK08 AC 227V - 500V BSLV3U Pack AC AC AC 24V 260V 415V KRC24 KRC48/260 KRC380/415 104716 104717 104718 110836 10 10 10 10 104760 104761 104762 10 10 10 CK07B ... CK12 Horizontal BEKH 104763 1 CK07B ... CK95 CK10C ... CK12B CK13 Vertical Vertical Vertical BEKVS 1 BEKVA 1 BEKV 104786 104785 104764 1 1 1 3P and 4P contactors CK85 ... CK13 CK85 ... CK13 CK85 ... CK13 Ref. no. Mechanical interlock Mounting A Pole terminal protection CK75C ... CK08C CK85B ... CK12B CK08B ... CK12B CK75C ... CK08C CK85B ... CK95B CK10C ... CK12B 1 pole. VDE0106 1 pole. VDE0106 1 pole. VDE0106 Contactors 3P Contactors 4P CM1CA5F C09476 C09479 105200 104766 204800 1 6 8 1 pole IPXXB 1 pole IPXXB 1 pole IPXXB PTPCK75 PTPCK95 PTPCK11 103747 103748 103749 1(1) 3(2) 1(1) B C D (1) One phase (2) Three pole E Spares Contact kits For use with: Type Cat. no. Ref. no. Pack F 1 1 1 1 1 1 1 1 1 1 1 1 G ne set consists of two fixed contacts, one moving contact and accessory parts. O When contact replacement is needed, it is recommended to replace all the contacts at the same time. CK07B NA V1107BA 113612 CK75C NA V1175CA 113613 CK08C NA V1108CA 113614 CK08B NA Contactors 4P V1108B4 113505 CK85B NA V1185BA 113615 CK09B NA V1109BA 113616 CK09B NA Contactors 4P V1109B4 113899 CK95B NA V1195BA 113617 CK10C NA V1110CE 113618 CK11C NA V1111CE 113619 CK12B NA V1112BA 113620 CK13B NA V1113BA 113621 H I X C.21 Series M Contactors Notes A B C D E F G H I X C.22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Series M Technical data General Shock resistance (IEC 68-2-27) MC0... MC1... MC2... Continuously closed (at 0.8Us) Admissible acceleration Impulse duration Continuously opened (no voltage) Admissible acceleration Impulse duration 20 9 20 12 4 750 690 4 750 690 Conformity to standards IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 EN 50003 EN 50005 EN 50012 SEV 10254 JIS C8325 JEM 1038 NEMA ICS-1 UL 508 CSA C22.2/14 CENELEC HD 419 VDE 0660 NFC 63110 BS 4794 25 g 11 ms 20 g 11 ms Vibration resistance (IEC 68-2-6) Continuously closed (at 0.8Us) Admissible acceleration Sweep between Continuously opened (no voltage) Admissible acceleration Sweep between 15 g 10 - 200 Hz 5g (AC) - 35g (DC) 10 - 200 Hz Mounting positions Approvals cULus SETI IMQ Lloyd’s Register NEMKO DEMKO SEMKO RINA Bureau Veritas CE A B With the same pick-up and drop-out voltage With the same rated power Ambient conditions Storage temperature Operation temperature -40ºC to +60ºC Altitude up to 3000m from 3000 up to 4000m from 4000 up to 5000m -55ºC to +80ºC Nominal values 90%Ie 80%Ue 80%Ie 75%Ue -7% of connection voltage +4% of disconnection voltage With the same rated power C 7% of connection voltage +4% of disconnection voltage With the same rated power D Climatic resistance Continuous tests 40 / 125 / 56 Cold (72h) Temperature Dry heat (96h) Temperature Relative humidity Humid heat (56h) Temperature Relative humidity Cyclic tests First half-cycle (12h) Low temperature Relative humidity Second half-cycle (12h) Low temperature Relative humidity Number of consecutive cycles 3P and 4P minicontactors Rated thermal current Ith θ ≤ 60º(1) (A) 20 Rated operational current Ie(2) (A) 6 (3 x 440V, 50/60Hz, AC-3) Maximum number of poles 4 Rated insulation current Ui (V) 750 Rated operational current Ue (V) 690 (1) Insulated terminal type B 2.8 x 0.8 with wire 1 mm2: Ie = 8A, design DIN 46 247 (2) Max.operational current AC3, 3 -phase≤ 440V, according to IEC 947-4-1 E Terminal capacity -40ºC +125ºC < 50% +40ºC 95% Terminal with M3.5 screw (with pozidrive head and safety flange) Solid wire mm2 Flexible wire without terminal mm2 Flexible wire without terminal with cap mm2 mm2 Ring terminal Tightening torque 0.8 Nm - 7 Lb/in 0.75 to 2 x 2 w. 0.75 to 2.5 x 2 w. 0.75 to 2.5 x 1 w. 0.75 to 1 x 2 w. 0.8 Nm - 7 Lb/in +25ºC 93% +55ºC 95% 6 F G H Faston terminal 2.8 - 2 insulated terminals Terminal for printed circuit (Ø of PCB hole) Ring terminal cap Fork terminal cap mm2 1 x 2 w. 1.8 mm 7.8 mm 6.5 mm I X C.23 Series M Contactors Control circuit A B C D E F G H I X C.24 Rated insulation voltage (Ui) (V) Standard voltages (Us) 50Hz(V) 60Hz(V) DC (V) Operating voltages limits Operating (1) xUs Drop-out xUs Operating voltages limits with coil 50/60 Hz Operating xUs Drop-out xUs Consumption 50 or 60Hz - monofrequency coil Pick-up (VA) Seal (VA) 50/60Hz - bifrequency coil Pick-up (VA) Seal (VA) DC (W) Power factor Magnetic circuit open (cos ϕ) Magnetic circuit closed (cos ϕ) Power dissipation (W) Opening and closing times Values between ± %Us % Time on energisation NO (ms) Time on de-energisation NC (ms) Time on energisation NC (ms) Time on de-energisation NO (ms) Values at Us Time on excitation NO (ms) Time on desexcitation NC (ms) Time on excitation NC (ms) Time on desexcitation NO (ms) Maximum time without voltage (ms) Mechanical endurance Monofrequency coil 106 ops. Bifrequency coil 106 ops. DC 106 ops. Maximum rate No load Monofrequency coil ops./h Bifrequency coil ops./h DC ops./h AC1 and AC3 (at rated power) ops./h AC4 (at rated power) ops./h MC _ A... MC _ C... MC _ I... MC _ K... MC _ C...W 750 750 750 750 750 24 ... 690 6 ... 600 – – – 6 ... 440 – – 24 – – 24 – – 12 ... 440 0.8 ... 1.1 0.35 ... 0.55 0.8 ... 1.1 0.15 ... 0.4 0.8 ... 1.25 0.15 ... 0.3 0.7 ... 1.25 0.15 ... 0.35 0.7 ... 1.3 0.15 ... 0.3 0.8 ... 1.1 0.35 ... 0.55 – – – – – – – – 26 4 – – – – – – – – 32 6 – – – 3 – – 1.2 – – 2 – – 4 0.8 0.35 1.4 – – 3 – – 1.2 – – 2 – – 4 +10 ... -20 6 ... 13 8 ... 16 5 ... 11 6 ... 13 +10 ... -20 22 ... 36 9 ... 12 18 ... 27 5 ... 7 +25 ... -30 30 ... 70 9 ... 16 20 ... 45 5 ... 9 +25 ... -30 20 ... 50 9 ... 16 18 ... 35 5 ... 9 +30 ... -30 17 ... 28 9 ... 12 12 ... 25 5 ... 7 7 ... 12 8 ... 16 6 ... 10 6 ... 13 3 24 ... 27 9 ... 11 20 ... 26 5 ... 8 3 25 ... 45 9 ... 16 25 ... 35 5 ... 9 3 25 ... 40 9 ... 16 20 ... 30 5 ... 8 3 11 ... 23 9 ... 11 15 ... 21 5 ... 8 3 >15 >10 – – – 10 – – 10 – – 10 – – 10 9000 3600 – 1200 300 – – 9000 1200 300 – – 9000 1200 300 – – 9000 1200 300 – – 9000 1200 300 Series M Main circuit (poles) Electrical endurance 750 750 20 20 20 Category AC1 Number of operations 0...400 0...400 0...400 160 160 160 106 106 106 90 90 90 80 80 90 470 250 125 95 70 50 40 10 470 250 125 95 70 50 40 10 32 16 12 16 1.5 32 20 16 20 1.5 32 20 16 20 1.5 Category AC3 Number of operations MC0... MC1... MC2... 470 250 125 95 70 50 40 10 MC1... MC2... 750 3P and 4P minicontactors A 0.6 0.6 0.128 0.228 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 B 1 > 2 1 > 2 1 >2 C D E Category AC4 F MC1.../MC2... Number of operations MC0... (1) Insulated terminal type B 2.8 x 0.8 with wire 1 mm2 Ie = 8A acc. to DIN 46247 Standard motor power 0.6 0.06 G H I X Standard motor power Rated insulation voltage (Ui) (V) (acc. IEC 947-4) Rated thermal current (lth) (A) θ ≤ 60º (1) Frequency limits (Hz) Making capacity (r.m.s.) Ue ≤ 690V 50/60Hz (A) Breaking capacity (r.m.s.) Ue ≤ 440V (A) Ue = 500V (A) Ue = 690V (A) Short-time current 0.3 sec. (A) 1 sec. (A) 5 sec. (A) 10 sec. (A) 30 sec. (A) 1 min. (A) 3 min. (A) Recovery time min. Protec. against short-circuits (IEC 947-4). w/o TOR Coordination type “1” gL/gG (A) Coordination type “2” gL/gG (A) w/o welding contacts gL/gG (A) Circuit breaker rating (curve G CEE 19.1) Impedance per pole (mΩ) Power dissipation per pole AC1 (W) AC3 (W) Insulation resistance Between adjacent poles (mΩ) Between pole and earth (mΩ) Between input and output (mΩ) Guaranteed no overlap between NO and NC contacts Space (mm) Time (ms) MC0... MC 0... MC1... MC2... C.25 Series M Tripping characteristics (DC) Internal auxiliary contacts A B C Rated insulation voltage (Ui) IEC 60947-5 (V) Rated thermal current (Ith) θ ≤ 60ºC (1) (A) Making capacity according with IEC 60947-5-1 Ue ≤ 690 50-60 Hz (A) Ue ≤ 440V DC (A) Breaking capacity (r.m.s.) IEC 60947-5-1 AC-15 Ue ≤ 440V / 50-60 Hz (A) DC-13 Ue ≤ 110V DC (A) Ue = 220V DC (A) Ue = 48V DC (A) Minimum operational power (operational safety.) Short-circuit protection (A) (max.class gl fuse) w/o welding Insulation resistance Between adjacent contacts (mΩ) Between contacts and earth (mΩ) Between input and output (mΩ) Guaranteed no overlap between NO and NC contacts Space (mm) Minimal time (ms) Impedance (mΩ) Terminal capacity 750 16 160 160 106 3 1.2 10 5mA, 17V 10 > 10 > 10 > 10 0,5 >2 2.3 Same as main circuit (1) 1 pole in series (2) 2 poles in series (3) 3 poles in series Inductive circuit. DC-13 L/R ≤ 15 ms Electrical endurance 106 ops. DC (1) Insulated terminal type B 2.8 x 0.8 with wire 1 mm2 Ie = 8A acc. with DIN 46247 Tripping characteristics (AC) . . Operation AC-15 Electrical endurance AC . . D . E F Inductive circuit. DC-13 L/R ≤ 100 ms Electrical endurance 106 ops. DC . Contactors MC0 / MC1 / MC2 (1) 1 pole in series (2) 2 poles in series (3) 3 poles in series . . . . Inductive circuit. DC-13 L/R ≤ 1 ms Electrical endurance 106 ops. DC . G . H . . I . . X C.26 . (1) 1 pole in series (2) 2 poles in series (3) 3 poles in series Series M Instantaneous auxiliary contact blocks Tripping characteristics (DC) MACN..., MACL... Tripping characteristics (AC) Inductive circuit. DC-13 L/R ≤ 100 ms Electrical endurance 106 ops. DC . . . . . (1) 1 pole in series (2) 2 poles in series (3) 3 poles in series Inductive circuit. DC-13 L/R ≤ 15 ms Electrical endurance 106 ops. DC A B C . . . . D . (1) 1 pole in series (2) 2 poles in series (3) 3 poles in series E F Inductive circuit. DC-13 L/R ≤ 1 ms Electrical endurance 106 ops. DC Operation AC-15 Electrical endurance AC 3P and 4P minicontactors Rated insulation voltage (Ui) acc. IEC 60947-1 (V) 750 Rated thermal current (Ith) θ ≤ 60ºC (1) (A) 10 Making capacity (r.m.s.) according with IEC/EN 60947-5-1 AC-15 Ue ≤ 220V 50/60 Hz (A) 73 Ue = 380V 50/60 Hz (A) 38 Ue = 690V 50/60 Hz (A) 22 DC-13 Ue ≤ 100V DC (A) 2.6 L/R=100ms Ue = 220V DC (A) 1 Ue = 440V DC (A) 0.6 Breaking capacity (r.m.s.) acc. IEC/EN 60947-5-1 AC-15 Ue ≤ 220V 50/60 Hz (A) 73 Ue = 380V 50/60 Hz (A) 38 Ue = 690V 50/60 Hz (A) 22 DC-13 Ue ≤ 100V DC (A) 2 LR=100ms Ue = 220V DC (A) 0,8 Ue = 440V DC (A) 0.4 Rated voltage and rated current Ue-Ie AC-15 according to IEC 60947 120V - 6A 230V - 6A 400V - 4A 500V - 1A 600V - 1A according to UL, CSA A600 DC-13 according to IEC 60947 24V - 4A 48V - 2A 110V - 0.7A 220V - 0.3A 440V - 0.1A according to UL, CSA Q600 Minimum operational power (operational safety) 5 mA, 17V Short-circuit protection (A) 10 (max. class gl fuse) w/o welding Insulation resistance Between adjacent contacts (mΩ) > 10 Between contacts an earth (mΩ) > 10 Between input and output (mΩ) > 10 Guaranteed no overlap between NO and NC contacts Space (mm) 0,5 Minimal time (ms) > 2 Impedance (mΩ) 2.4 Terminal capacity Same as main circuit (1) Insulated terminal type B 2.8 x 0.8 with wire 1 mm2 Ie = 8A acc. with DIN 46247 G H . . . . . . . . . I . . (1) 1 pole in series (2) 2 poles in series (3) 3 poles in series X C.27 Series M Electronic timer block Contactors MREBC... A Rated insulation voltage (Ui) (V) Rated thermal current (Ith) θ ≤ 60ºC (1) (V) Supply voltage (AC and DC) (V) Operating limits Voltage drop (V) Maximum load current at : 20ºC (A) 40ºC (A) 60ºC (A) Minimum load for safe operation (A) Maximum current (A) Leakage current at 220V (mA) Operational current AC-15 (A) DC-13 (A) Timing range (delay ON) (s) Rearrangement time (ms) Repeatibility (accuracy)(%) ±1 Ambient temperature storage (ºC) operation (ºC) Degree of protection Mounting positions Terminals : 2 free cables 750 0.55 24 to 250 0.80 to 1.1 Us (0.85 to 1.1 Us to 12V) <3 0.9 0.72 0.55 > 10 10A per 40 ms <5 0.7 0.9 0.5 to 60 (± 6 s) < 100 –55 to + 80 –5 to + 60 IP20 Any 1 mm2 (AWG 17) 250 mm B C D E Contact sequence Main contact (NO) Main contact (NC) Auxiliary contact (NO) Auxiliary contact (NC) F G Three-pole minicontactor MC...310... H MC...301... 0 2 3.5 0 2 3.5 0 2 3.5 0 2 3.5 0 2.33.5 0 1.2 3.5 Four-pole minicontactor I MC...400... MC...B00... X MC...A00... 0 1.2 3.5 0 1.2 3.5 Auxiliary contact block MAC... MAR... C.28 0 2.13.5 0 1 3.5 0 2.13.5 0 1 3.5 Series M Terminal numbering in accordance with EN 50012 Final structure of the contactor Auxiliary contactors Combination Possible basic contactors + Auxiliary contact blocks to be added Description NO NC 01E 0 1 MC_A301A... 10E 1 0 MC_A310A... 11E 1 1 MC_A310A... + MACN211A 21E 2 1 MC_A310A... + MACN211A 12E 1 2 MC_A310A... + MACN202A 31E 3 1 MC_A310A... + MACN431A 41E 4 1 MC_A310A... + MACN431A 22E 2 2 MC_A310A... + MACN422A 32E 3 2 MC_A310A... + MACN422A 13E 1 3 MC_A310A... + MACN413A 23E 2 3 MC_A310A... + MACN413A 11E 1 1 MC_A310A... + MACL101A 21E 2 1 MC_A310A... + MACL101A + MACL110A 12E 1 2 MC_A310A... + MACL101A + MACL101A Without auxiliary contact blocks Auxiliary contact blocks lateral mounted with one contact 3P and 4P minicontactors Auxiliary contact blocks front mounted with two or four contacts A B C D E F G H I X C.29 Series M Terminal numbering Base four-pole contactors. (EN 50005) Basic three-pole contactors. (EN 50012) MC _ _ 400A _ MC _ _ 310A _ MC _ _ B00A _ MC _ _ 301A _ MC _ _ A00A _ Contactors Instantaneous auxiliary contact blocks. (EN 50012) MACL110A _ MACL101A _ MACN211A_ Instantaneous auxiliary contact blocks. (EN 50005) MACN202A_ MACN431A_ MARL110A_ MARL101A_ MARL110A_S MARL101A_S MARN220A_ MARN211A_ MARN202A_ MARN440A_ MARN431A_ MARN422A_ MARN413A_ MARN404A_ MACN422A_ A B MACN413A_ C D E Instantaneous auxiliary contact blocks. (EN 50005) MARL110A_S MARL101A_S MARN220A_ MARN211A_ MARN202A_ MARN440A_ F G Voltage suppressor block H I MP0AAE _ MARN431A_ MARN413A_ MP0CAE4 X MARN404A_ C.30 MARN422A_ MP0CAE3 Series CL Conformity to standards IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 508 CSA 22.2/14 Climatic resistance (IEC 68-2) EN 50005 CENELEC HD419 NF C63-110 ASE 1025 Continuous tests 40 / 125 / 56 Cold (72h) Temperature -40ºC Dry heat (96h) Temperature +125ºC Relative humidity < 50% Humid heat (56h) Temperature +40ºC Relative humidity 95% UNE 20109 BS 5424 & 775 NEMA ICS 1 VDE 0660/102 Approvals RINA IMQ (up to Ith:32A) Bureau Veritas CE +25ºC 93% +55ºC 95% 3P and 4P contactors cULus SETI Lloyd’s Register Cyclic test (6 cycles) Humid heat First half-cycle (12h)) Low temperature Relative humidity Second half-cycle (12h) Low temperature Relative humidity Mounting positions Ambient conditions Storage temperature Operation temperature Altitude up to 3000m from 3000 up to 4000m from 4000 up to 5000m -55ºC to +80ºC -40ºC to +60ºC Nominal values 90%Ie 80%Ue 80%Ie 75%Ue With the same pick-up and drop-out voltage With the same rated power Terminal capacity and tightening torque CL00 ... CL02 CL25 CL03 ...CL04 CL45 CL05 ... CL08 CL09 ... CL10 Solid, stranded and finely stranded without end sleeve (mm2) Finely stranded with or without end sleeve (mm2) AWG wires Tightening torque (Nm) (Lb x in.) Solid, stranded and finely stranded without end sleeve (mm2) Finely stranded with end sleeve (mm2) Finely stranded w/o end sleeve (mm2) AWG wires Tightening torque (Nm) (Lb x in.) Solid (mm2) Stranded (mm2) Finely stranded w/o end sleeve (mm2) Finely stranded with end sleeve (mm2) AWG wires Tightening torque (Nm) (Lb x in.) Solid, stranded and finely stranded without end sleeve (mm2) Finely stranded w/o end sleeve (mm2) Finely stranded with end sleeve (mm2) AWG wires Tightening torque (Nm) (Lb x in.) Ring terminals (Ø i) (acc. with IEC/EN 60947-1) (A) Tightening torque (Nm) (Lb x in.) 2 x 0.5 ... 2.5 2 x 2.5 ... 6 2 x 1 ... 2,5 2 x 2.5 ... 6 2 x 20 ... 12 1.6 15 2 x 0.5 .. 2.5 2 x 2.5 ... 10 2 x 1 ... 2,5 2 x 2.5 ... 10 2 x 20 ... 8 2.2 20 – – – – – – – – – – – – – – – – – – – – – – – – – – – – 1 ... 35 1 ... 35 1 ... 35 16 ... 2 4 35 1 ... 16 1 ... 25 1 ... 25 1 ... 25 16 ... 4 4 35 Max. 50 ... 4 Max. 25 ... 16 Max. 25 ... 16 Max. 25 ... 25 Max. 2 ... 12 Max 4 ... 4 4 35 6.2 12.5 3 26 1.5 ... 50 1.5 ... 50 1.5 ... 50 16 ... 2 5,6 50 4 ... 35 4 ... 35 4 ... 35 4 ... 35 10 ... 1 5.6 50 Max. 50 ... 35 – – – – – – – – – – – – – – – – – – – – – 3,6 8 1,6 15 – 0.75 ... 16 0.75 ... 16 – 0.75 ... 16 0.75 ... 16 – 1 ... 16 1 ... 16 – 18 ... 6 18 ... 6 – 1,4 1,8 – 12 16 – 0.75 ... 16 0.75 ... 16 – 0.75 ... 16 0.75 ... 16 – 0.75 ... 16 0.75 ... 16 – 1 ... 16 1 ... 16 – 18 ... 6 18 ... 6 – 1.4 1.8 – 12 16 – Max. 16 Max. 16 – – – – Max. 6 Max. 6 – – 1.4 1.8 – 12 16 4,2 4.2 4.2 10 10 10 1,4 1.4 1.4 12 12 12 Max. 1 5.6 50 6.2 12.5 3 26 A B C D E F G H I X C.31 Series CL Power circuit CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL05 CL06 CL07 CL08 CL09 CL10 Rated thermal current Ith at θ ≤ 55ºC (A) 25 9 Rated operational current Ie AC-3 (A) Rated operational voltage Ue (V) 690 25 12 690 32 18 690 45 25 690 45 25 690 60 32 690 60 40 690 - - - 90 50 690 110 65 690 110 80 690 140 95 690 140 105 690 25 690 32 690 - - 45 690 60 690 - - 90 690 - - 110 690 110 690 140 690 - Three pole version Four pole version (4NO and 2NO+2NC) Rated thermal current Ith at θ ≤ 55ºC (A) Rated operational voltage Ue (V) Contactors Three and four pole version A B C D E F G H I X C.32 Rated insulation voltage Ui (V) Maximum continuous current AC-1 (A) Frequency limits (Hz) Making capacity (RMS) (IEC 947) (A) Breaking capacity (RMS) (IEC 947) Ue ≤ 400V (A) Ue = 500V (A) Ue = 690V (A) Short-time current 1 sec. (A) 5 sec. (A) 10 sec. (A) 30 sec. (A) 1 min. (A) 3 min. (A) Recovery time (min.) Protec. against short-circuit with fuses without TOR Coordination type “1” gL/gG (A) Coordination type “2” gL-gG (A) Without welding gL-gG (A) Impedance per pole (mΩ) Power dissipation per pole AC-1 (W) AC-3 (W) Insulation resistance Between adjacent poles (mΩ) Between poles and earth (mΩ) Between input and output (mΩ) - - 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 25 25 32 45 45 60 60 90 90 110 110 140 140 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 450 450 450 450 550 550 550 1000 1000 1000 1000 1280 1280 250 250 130 250 250 130 250 250 130 350 320 170 450 450 205 450 450 205 450 450 205 920 920 780 920 920 780 920 920 780 920 920 780 1050 1050 950 1050 1050 950 455 205 144 85 60 35 10 455 205 144 85 60 35 10 570 254 180 104 74 46 10 630 280 200 115 80 50 10 1010 450 320 185 130 90 10 1010 450 320 185 130 90 10 1265 450 400 230 165 100 10 1580 565 500 290 205 120 10 1580 710 500 290 205 120 10 2530 1130 800 460 325 185 10 2530 1130 800 460 325 185 10 3300 1485 1050 600 430 250 10 3300 1485 1050 600 430 250 10 50 50 63 63 100 100 125 200 200 200 200 250 250 25 35 35 50 63 63 80 100 100 125 125 160 200 10 2.35 10 2.35 25 2.41 35 1.65 35 1.28 35 1.28 50 0.95 80 0.85 80 0.85 100 0.86 100 0.86 140 0.76 160 0.76 1.47 0.19 1.47 0.34 2.46 0.78 3.34 1.03 2.59 0.80 4.6 1.31 3.42 1.52 6.89 1.36 6.86 2.12 10.40 3.63 10.40 5.5 14.89 6.86 14.89 8.37 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 Series CL Control circuit Alternating current Rated insulation voltage Ui CL00 ... CL25 CL03 ... CL45 CL05 ... CL08 CL09 ... CL10 1000 24...690 24...600 1000 24...690 24...600 1000 24...690 24...600 1000 24...690 24...600 0.8...1.1 0.6...0.8 0.35...0.55 0.8...1.1 0.65...0.8 0.4...0.6 0.8...1.1 0.65...0.8 0.4...0.6 0.8...1.1 0.65...0.8 0.4...0.6 0,8...1,1 0,85...1,1 0,5...0,8 0,65...0,85 0,3...0,55 0,35...0,65 0.8...1.1 0.85...1.1 0.6...0.8 0.7...0.85 0.35...0.60 0.4...0.6 0.8...1.1 0.85...1.1 0.6...0.8 0.7...0.85 0.35...0.60 0.4...0.6 0.8...1.1 0.85...1.1 0.6...0.8 0.7...0.85 0.35...0.60 0.4...0.6 6 48 9 88 15.5 190 15.5 190 6.8 / 5.6 53 / 44 2.2 / 1.8 11.4 / 9.5 120 / 100 3.2 / 2.6 20 / 16.6 245 / 204 5.2 / 4.3 20 / 16,6 245 / 204 5.2 / 4.3 0.33 0.84 0.28 0.73 0.26 0.54 0.26 0.54 6...20 6...13 7...25 5...25 9...35 9...15 9...35 9...15 8...20 6...13 10...19 5...25 15...30 9...15 15...30 9...15 15 10 15 10 15 8 15 8 9000 1200 1000 1200 360 3600 9000 1200 1000 1200 360 3600 9000 1200 1000 1200 200 3600 5000 1200 750 600 200 3600 (V) (V) (V) Coils with electronic module Direct current Rated insulation voltage Ui (V) Standard voltages Us (V) Operating limits Operating xUs Pick-up xUs Drop-out xUs Consumption Magnetic circuit closed (W) Magnetic circuit opened (W) Opening and closing times Values between + 10 % Us and – 20 % Us Time on energisation (NO) (ms) Time on de-energisation (NO) (ms) Values at Us Time on energisation (NO) (ms) Time on de-energisation (NO) (ms) Mechanical endurance 106 ops. Maximum rate No load ops./h AC1 and AC3 at rated power ops./h AC4 at rated power ops./h CL00D ... CL25D 1000 12...440 3P and 4P contactors Standard voltages Us 50 Hz Standard voltages Us 60 Hz Voltage operating limits monofrequency coils Operating xUs Pick-up xUs Seal xUs Voltage operating limits 50/60 Hz coils Operating 50 Hz xUs Operating 60 Hz xUs Pick-up 50 Hz xUs Pick-up 60 Hz xUs Seal 50 Hz xUs Seal 60 Hz xUs Consumption monofrequency coils Magnetic circuit closed (VA) Magnetic circuit opened (VA) Consumption bifrequency coils Magnetic circuit closed (50 Hz/60 Hz) (VA) Magnetic circuit opened (50 Hz/60 Hz) (VA) Thermal power dissipation (50 Hz/60 Hz) (W) Power factor Magnetic circuit closed cos ϕ Magnetic circuit opened cos ϕ Opening and closing times Values between + 10 % Us and – 20 % Us Time on energisation (NO) (ms) Time on de-energisation (NO) (ms) Values at Us Time on energisation (NO) (ms) Time on de-energisation (NO) (ms) Mechanical endurance Monofrequency coils 106 ops. Bifrequency coils (at 50 Hz) 106 ops. Maximum rate Monofrequency coils. No load ops./h AC-1 at rated power ops./h AC-2 at rated power ops./h AC-3 at rated power ops./h AC-4 at rated power ops./h Bifrequency coils. No load ops./h A B C D E Coils with wide voltage range CL03D ... CL45D CL05E ... CL08E CL09E ... CL10E CL00D..W ... CL25D..W CL03D..W ... CL45D..W CL05D..W ... CL10D..W 1000 12...440 1000 24...440 1000 24...440 1000 12...440 1000 12...440 1000 12...440 0.8...1.1 0.8...1.1 0.45...0.65 0.45...0.65 0.15...0.3 0.15...0.3 0.8...1.1 0.8...1.1 0.70...0.80 0.70...0.80 0.4...0.6 0.4...0.6 0.7...1.3 0.7...1.3 0.45...0.55 0.45...0.55 0.15...0.3 0.15...0.3 F G 0.7...1.3 0.45...0.55 0.15...0.3 H 5.5 5.5 8 8 10 170 10 170 6.5 6.5 10.4 10.4 20 20 I 35...65 6...15 35...70 40...65 60...80 40...50 60...80 40...50 26...55 6...15 30...65 5...10 64...133 20...23 X 35...45 7...12 15 40...55 30...65 15 50...60 55...60 12 50...60 55...60 12 35...45 7...12 15 40...55 6...8 15 75...95 20...22 12 3600 1200 360 3600 1200 360 2500 1200 200 2500 600 200 3600 1200 360 3600 1200 360 3600 1200 200 C.33 Series CL Electrical endurance Mixed category AC4 / AC3 Electrical endurance for mixed category (AC-3/AC-4) is calculated with the following formula : Electrical endurance = (AC-3/AC-4) Electrical endurance (AC-3) 1 + % oper AC-4 100 Contactors Category AC1 Number of operations A B Ic=Ie for all voltages C D Category AC2 E Number of operations F G H C.34 . . . . . . . . . . . . . . . . . . . Rated motor power (Ic = 2,5 Ie) . X . . I X (AC-3) -1 ) ( Elec.endur. Elec.endur.(AC-4) Series CL Category AC3 3P and 4P contactors Number of operations . . . . . B . . . . . . . . . . . . . . . . . A Rated motor power (Ic = Ie) C Category AC4 D E Number of operations F G H . . . . . . X . . . . . . . . . . . . . . . Rated motor power (Ic = 6 Ie) . I C.35 Series CL Internal auxiliary contacts Contactors CL00 ... CL02 A Rated insulation voltage Ui according to IEC 60947 (V) Rated thermal current Ith a θ ≤ 55ºC (A) Making capacity (r.m.s.) acc. to IEC 60947 AC-15 Ue ≤ 400V, 50/60 Hz (A) DC-13 Ue ≤ 220V DC (A) Breaking capacity (r.m.s.) acc.to IEC 60947 AC-15 Ue ≤ 400V, 50/60 Hz (A) DC-13 Ue ≤ 220V DC (A) AC-15 Rated voltage and current Ue-Ie according to IEC according to UL, CSA DC-13 Rated voltage and current Ue-le according to IEC according to CSA Electrical endurance ops. Minimum operational power (operational safety) Short-circuit protect. Max.fuse class gl-gG without welding (A) Insulation Between contacts (mΩ) resistance Between contacts and earth (mΩ) Between input and output (mΩ) Guaranteed no overlap between NO and NC contacts Space (mm) Time (ms) Impedance of the contacts (mΩ) CL03 ... CL04 1000 20 1000 20 250 250 250 250 250 2 110/120V-10A 220/230V-10A 400/380V-6A 415/450V-5A 500V-4A 690/660V-2A A600 24V-6A 48V-4A 110V-2A 220V-0.7A 440V-0.35A P600 106 17V - 5mA 10 > 10 > 10 > 10 250 2 110/120V-10A 400/380V-6A 500V-4A 230/220V-10A 415/450V-5A 690/660V-2A A600 24V-6A 110V-2A 440V-0.35A 48V-4A 220V-0.7A P600 106 17V - 5mA 10 > 10 > 10 > 10 1.3 1.5 1.28 2.6 1.5 1.28 Instantaneous BCLF..., BCRF..., BCLL..., BRLL... Timed blocks BTLF..., BTRF... B Auxiliary contact blocks C D E F G H I X C.36 Rated insulation voltage Ui according to IEC 60947 (V) 1000 1000 Rated thermal current lth at θ ≤ 55ºC (A) 10 10 Making capacity (Ieff) according to IEC 60947 AC-15 Ue ≤ 400V, 50/60 Hz (A) 90 90 DC-13 Ue ≤ 220V DC (A) 90 90 Breaking capacity (Ieff) according to IEC 60947 AC-15 Ue ≤ 400V, 50/60 Hz (A) 60 60 DC-13 Ue ≤ 220V, DC (A) 0.95 0.95 AC-15 Rated voltage and current Ue-Ie according to IEC 120/110V-6A 230/220V-6A 120/110V-6A 230/220V-6A 400/380V-4A 440/415V-3.5A 400/380V-4A 440/415V-3.5A 500V-2.5A 690/660V-1.5A 500V-2.5A 690/660V-1.5A according to UL, CSA A600 A600 DC-13 Rated voltage and current Ue-Ie according to IEC 24V-4A 48V-2A 24V-4A 48V-2A 110V-0.7A 220V-0.3A 110V-0.7A 220V-0.3A 440V-0.15A 440V-0.15A according to UL, CSA Q600 Q600 Electrical endurance 106 ops. 1 1 Mechanical endurance 106 ops. 10 5 Minimum operational current (operational safety) 17V - 5mA 17V - 5mA Short-circuit protect. Max.fuse class gl-gG without welding (A) 10 10 Insulation Between contacts (mΩ) > 10 > 10 resistance Between contacts and earth (mΩ) > 10 > 10 Between input and output (mΩ) > 10 > 10 Guaranted no overlap between NO and NC contacts Space (mm) 1.3 1.3 Time (ms) 1.5 5 Impedance of the contacts (mΩ) 1.28 1.28 Timing (ambient temperature between – 25ºC and + 55ºC) Accuracy – ± 5% Loss of accuracy 0.5 x 106 ops. – + 20% Loss of accuracy per rise ºC (0 - 55ºC) – + 0.75% per ºC Series CL Mechanical latch blocks RMLF... according to UL/CSA Utilisation DC-13 according to IEC according to UL/CSA Mechanical endurance CL00...CL45 CL05...CL10 Wiring diagram Alternating current 1000 V 24...690 V 0.75...1.1 xUs 210 W / VA 130 W / VA 10 ms auto cut-out by integral contact by local push-button 40 ms auto cut-out by integral contact by local push-button 120V - 6A 230V/220V - 4A 400V/380V - 2.5A 500V - 1.5A 690V/660V - 1A A600 24V - 3A 48V - 1.5A 110V - 0.6A 220V - 0.3A 400V - 0.15A Q600 3P and 4P contactors Rated insulation voltage Ui Standard voltages Us : 50 to 60 Hz and DC Operating limits Consumption for unlatching (auto cut-out) 24 to 72 V 110 to 440 V Electrical unlatching control (1) Minimum impulse Maintained Manual unlatching control Electrical making control Minimum pulse Manual making control Auxiliary contact NC Utilisation AC-15 according to IEC 3 million (1200 ops./h) 0.1 million (300 ops./h) A B Alternating current / Direct current C (1) The contactor coil and the unlatch control must not be energised simultaneously D E Terminal capacity Terminal: screw BCLF, BCLL, BTLF y RMLF Solid Stranded and finely stranded without end sleeve Finely stranded with end sleeve AWG wires, solid and stranded Tightening torque Ring terminal Øi A Tightening torque Terminal: ring terminal BCRF, BTRF 2 x 0.5 to 2.5 or 1 x 4 2 x 0.5 to 2.5 or 1 x 4 2 x 0.5 to 2.5 or 1 x 4 12 - 22 AWG 75ºC 1.1 Nm / 10 Lb x in. F G 3.6 min. 6.5 max. 0.8 Nm / 7 Lb x in. H I X C.37 Series CL Contact sequence Basic contactor Auxiliary contact blocks Front mounted BCLF 01 BCRF 01 BCLF 10 BCRF 10 Three pole contactors 3 NO Auxiliary contact blocks Lateral mounted BCLL 20 BRLL 20 BCLL 11 BRLL 11 CL00... CL01... CL02... 0 3.3 4.7 0 3.2 4.7 0 CL25... 0 3 5.1 0 3.7 5.1 0 CL03... CL04... 0 4 5.6 0 3.7 5.6 0 CL45... 0 4.3 6.5 0 CL06... 0 5.4 8 0 3.7 8 0 1.6 8 0 3.7 8 0 0 8 0 3.7 8 0 1.6 8 0 3.7 8 0 1.6 CL07... CL08... 1.6 CL09... 0 5.6 8 0 3.7 8 0 1.6 8 0 3.7 8 0 CL10... 0 5.6 8 0 3.7 8 0 1.6 8 0 3.7 8 0 CL01... CL02... 0 3.3 4.7 0 3.2 4.7 0 1.4 4.7 0 3.2 4.7 0 D CL03... CL04... 0 4 5.6 0 3.7 5.6 0 1.6 5.1 0 3.7 5.6 0 E CL05... 0 5.4 8 0 3.7 8 0 1.6 8 0 3.7 8 0 0 8 0 3.7 8 0 1.6 8 0 3.7 8 0 1.6 CL07... 1.6 CL09... 0 8 0 3.7 8 0 1.6 8 0 3.7 8 0 1.4 4.7 0 3.2 1.6 5.1 0 3.7 5.1 0 1.6 5.6 0 3.7 5.6 0 4.7 0 Contactors 6.5 0 1.6 6.5 0 3.7 4.8 B Four pole contactors 4 NO 4.8 4.7 3.7 5.1 3.7 5.6 1.4 1.6 1.6 6.5 0 A C 3.7 3.2 3.7 6.5 1.6 3.7 8 3.7 8 3.7 8 3.7 8 1.6 1.6 3.2 4.7 3.7 5.6 1.4 1.6 3.7 8 3.7 8 3.7 8 F 5.6 G H CL01... 0 Four pole contactors CL02... 2 NO + 2 NC CL07... 0 CL08... C.38 3.2 4,7 0 1.4 4.7 0 3.2 4.7 0 4 5.6 0 3.7 5.6 0 1.6 5.1 0 3.7 5.6 0 5.4 8 0 3.7 8 0 1.6 8 0 3.7 8 0 8 0 3.7 8 0 1.6 8 0 3.7 8 0 3.7 4.8 4.3 1.6 3.2 4.7 1.4 1.5 CL05... 0 X 4.7 0 1.6 CL03... 0 CL04... I 3.3 3.7 5.6 1,6 3.7 8 3.7 8 1.6 1.6 Series CL Terminal numbering Three-pole and four-pole AC contactors CL00A300_ _ ... CL10A300_ _ CL25D300_ _ ... CL45D300_ _ CL06E300_ _ ... CL10E300_ _ CL00_301_ _ ... CL02_301_ _ CL03_301_ _ ... CL04_301_ _ CL45A311_ _ ... CL10A311_ _ CL25_301_ _ CL00A400_ _ ... CL08A400_ _ CL01D400_ _ ... CL04D400_ _ CL05E400_ _ ... CL09E400_ _ CL01AB00_ _ ... CL08AB00_ _ CL01DB00_ _ ... CL04DB00_ _ CL05EB00_ _ ... CL08EB00_ _ Auxiliary contact blocks. Front mounting BC_ F10 BC_ F01 BCLF10G Auxiliary contact blocks. Lateral mounting BCLF01G BCLL20 BCLL11 3P and 4P contactors CL25_310_ _ CL00_310_ _ ... CL02_310_ _ CL03_310_ _ ... CL04_310_ _ A BRLL20 BRLL11 B Pneumatic timer blocks BT_F_C BT_F_D C Electronic timer blocks Mechanical and mechanical/electrical interlock BELA BETL_ _C BETL_ _D D BELA02 E F Voltage suppressor blocks BSLR2, BSLR3 IMRC BSLDZ IMD1Z BSLV3 IMV3 Mechanical latch block RMLF c. alterna AC /DC G H Interface modules IMRD, IMRG IMSSD IMRFD, IMRFG IMAMS I X C.39 Series CL Terminal numbering according to EN 50012 Auxiliary contacts Possible basic contactors + Auxiliary contacts blocks to be added Combination Description NO NC 10E 1 0 01E 0 1 Without auxiliary contact blocks CL00_310_... - CL04_310_... CL00_301_... - CL04_301_... Contactors Front mounting auxiliary contact blocks with one contact each A 11E 1 1 CL00_310_... - CL04_310_... + BC_F01 21E 2 1 CL00_310_... - CL04_310_... + BC_F01 + BC_F10 12E 1 2 CL00_310_... - CL04_310_... + BC_F01 + BC_F01 31E 3 1 CL00_310_... - CL04_310_... + BC_F01 + BC_F10 + BC_F10 41E 4 1 CL00_310_... - CL04_310_... + BC_F01 + BC_F10 + BC_F10 + BC_F10 22E 2 2 CL00_310_... - CL04_310_... + BC_F01 + BC_F01 + BC_F10 32E 3 2 CL00_310_... - CL04_310_... + BC_F01 + BC_F01 + BC_F10 + BC_F10 13E 1 3 CL00_310_... - CL04_310_... + BC_F01 + BC_F01 + BC_F01 23E 2 3 CL00_310_... - CL04_310_... + BC_F01 + BC_F01 + BC_F01 + BC_F10 B C D E F G Lateral mounting auxiliary contact blocks with two contacts each H 11E 1 1 CL00_300_... - CL45_300_... + BCLL11 I 31E 3 1 CL00_300_... - CL45_300_... + BCLL11 + BCLL20 X 22E 2 2 CL00_300_... - CL45_300_... + BCLL11 + BCLL11 The maximum number of auxiliary contacts is 4 for CL00 to CL25, 6 for CL03 -CL04 and 8 for CL45, CL06 to CL10.When using the pneumatic BTLF-block, thesenumbers are reduced to two, resp .four.( 2 for CL00 to CL25, 4 for CL03 and CL04, etc.) C.40 Series CL Terminal numbering according to EN 50012 (continued) Auxiliary contacts Combination Description NO Possible basic contactors + Auxiliary contacts blocks to be added NC Without auxiliary contact blocks CL25_300_... - CL45_300_... CL06_300_... - CL10_300_... 10E 1 0 CL25_300_... - CL45_300_... + BC_F10 CL06_300_... - CL10_300_... + BC_F10 01E 0 1 CL25_300_... - CL45_300_... + BC_F01 CL06_300_... - CL10_300_... + BC_F01 11E 1 1 CL25_300_... - CL45_300_... + BC_F10 + BC_F01 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 21E 2 1 CL25_300_... - CL45_300_... + BC_F10 + BC_F01 + BC_F10 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 + BC_F10 CL25_300_... - CL45_300_... + BC_F10 + BC_F01 + BC_F01 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 + BC_F01 CL25_300_... - CL45_300_... + BC_F10 + BC_F01 + BC_F10 + BC_F10 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 + BC_F10 + BC_F10 12E 31E 41E 22E 32E 13E 23E 1 3 4 2 3 1 2 2 1 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 + BC_F10 + BC_F10 + BC_F10 1 2 CL25_300_... - CL45_300_... + BC_F10 + BC_F01 + BC_F01 + BC_F10 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 + BC_F01 + BC_F10 + BC_F10 2 3 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 + BC_F01 + BC_F10 CL25_300_... - CL45_300_... + BC_F10 + BC_F01 + BC_F01 + BC_F01 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 + BC_F01 + BC_F01 CL06_300_... - CL10_300_... + BC_F10 + BC_F01 + BC_F01 + BC_F01 + BC_F10 3 3P and 4P contactors Front mounting auxiliary contact blocks with one contact each A B C D E F G H Lateral mounting auxiliary contact blocks with two contacts each 11E 1 1 CL25_300_... - CL45_300_... + BCLL11 CL06_300_... - CL10_300_... + BCLL11 31E 3 1 CL25_300_... - CL45_300_... + BCLL11 + BCLL20 CL06_300_... - CL10_300_... + BCLL11 + BCLL20 22E 2 2 CL25_300_... - CL45_300_... + BCLL11 + BCLL11 CL06_300_... - CL10_300_... + BCLL11 + BCLL11 I X C.41 Series CK Mounting positions Conformity to standards IEC/EN 60947-1 IEC/EN 60947-4-1 CENELEC HD 419 UL 508 EN 50005 NF C 63-110 ASE 1025 CSA 22.2/14 UNE 20109 BS 5424 & 775 NEMA ICS 1 VDE 0660/102 Approvals cULus NOM Lloyd’s Register RINA FI Bureau Veritas CE With the same pick-up and drop-out voltage With the same rated power Contactors Ambient conditions A B C D Storage temperature Operation temperature -40ºC to +60ºC Altitude up to 3000m from 3000 up to 4000m from 4000 up to 5000m -55ºC to +80ºC Nominal values 90%Ie 80%Ue 80%Ie 75%Ue Climatic resistance (IEC 68-2) Continuous tests 40 / 125 / 56 Cold (72h) Temperature Dry heat (96h) Temperature Relative humidity Humid heat (56 days) Temperature Relative humidity Cyclical test First half-cycle (12h) Low temperature Relative humidity Second half-cycle (12h) Low temperature Relative humidity Number of consecutive cycles -40ºC +125ºC < 50% +40ºC 95% +25ºC 93% +55ºC 95% 6 Terminal capacity and tightening torque CK07B E F Solid (mm2) Finely stranded w/end sleeve (mm2) Finely stranded w/o end sleeve (mm2) Stranded (mm2) AWG wires (mm2) Tightening torque (Nm) (Lb x in) Finely stranded w/end sleeve (mm2) G AWG wires with end sleeve (mm2) H Busbars Tightening torque I X C.42 (Nm) (Lb x in)) CK75C CK08C CK08B CK95B CK10C CK11C CK12B CK13B – – – 2 (35 x 10) 31.5 275 – 2 (60 x 10) 31.5 275 1.5...95 2...35 2...50 1.5...95 16...00 8 70 1 x 120 2 x 95 1 x 300 2 x 107 2 (25 x 5) 8 70 1 x 240 2 x 150 1 x 500 2 x 300 2 (25 x 5) 23 200 2 x 185 2 x 240 2 x 350 2 x 500 2 (35 x 10) 2 (35 x 10) 31.5 31.5 275 275 Series CK Power circuit Three pole contactors CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B 250 150 1000 1000 250 25...400 1850 250 185 1000 1000 250 25...400 2200 315 205 1000 1000 315 25...400 2500 315 250 1000 1000 315 25...400 2500 450 309 1000 1000 450 25...400 3700 600 420 1000 1000 600 25...400 6500 700 550 1000 1000 700 25...400 6500 1000 700 1000 1000 1000 25...400 8400 1250 825 1000 1000 1250 25...400 8250 1600 1600 1000 350 2500 2500 2300 1250 900 600 10 1850 1850 1200 350 2500 2500 2300 1250 900 600 10 2000 2000 1660 850 4000 3200 2400 1400 1000 750 10 3500 3500 2200 1100 5500 3500 2500 1600 1200 900 10 3500 3500 2200 1100 5500 3500 2500 1600 1200 900 10 5600 5600 5000 3000 7500 5200 4000 2800 1800 1200 10 5600 5600 5000 3000 7500 5200 4000 2800 1800 1200 10 7300 7000 6700 3500 9700 7700 6100 4400 3500 2300 10 6600 6600 6000 3500 11600 8800 7350 5300 4500 2800 10 355 250 200 0.30 19 6.8 355 250 200 0.30 19 10.3 500 315 250 0.28 27.7 11.7 500 400 315 0.28 27.7 17.5 630 500 425 0.28 56.7 26.7 1250 630 500 0.15 54.3 26.5 1250 800 630 0.13 63.7 45.3 1250 1000 800 0.14 140 68.6 2x800 1250 1000 0.11 171.8 74.8 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 CK09B CK95B CK10C CK11C CK12B CK13B 400 1000 1000 400 25...400 2500 500 1000 1000 500 25...400 3700 600 1000 1000 600 25...400 6500 700 1000 1000 700 25...400 6500 1000 1000 1000 1000 25...400 6700 1250 1000 1000 1250 25...400 8250 3P and 4P contactors Rated thermal current Ith at θ ≤ 40ºC (A) Rated operational current Ie AC-3 (A) Rated operational voltage Ue (V) Rated insulation voltage Ui (V) Maximum continuous current AC-1 (A) Frequency limits (Hz) Making capacity (RMS) (IEC 947) (A) Breaking capacity (RMS) (IEC 947) Ue ≤ 400V (A) Ue = 500V (A) Ue = 690V (A) Ue = 1000V (A) Short-time current 1 sec. (A) 5 sec. (A) 10 sec. (A) 30 sec. (A) 1 min. (A) 3 min. (A) Short-time current (min.) Protec. against short-circuit with fuses without TOR Coord. type “1” gL/gG (A) Coord. type "2" gL/gG (A) Without welding gL/gG (A) Impedance per pole (mΩ) Power dissipation AC-1 (W) per pole AC-3 (W) Insulation resistance Between adjacent poles (mΩ) Between poles and earth (mΩ) Between input and output (mΩ) CK75C A B C Four pole contactors Rated thermal current Ith at θ ≤ 40ºC (A) Rated operational voltage Ue (V) Rated insulation voltage Ui (V) Maximum continuous current AC-1 (A) Frequency limits (Hz) Making capacity (RMS) (IEC 947) (A) Breaking capacity (RMS) (IEC 947) Ue ≤ 400V (A) Ue = 500V (A) Ue = 690V (A) Ue = 1000V (A) Short-time current 1 sec. (A) 5 sec. (A) 10 sec. (A) 30 sec. (A) 1 min. (A) 3 min. (A) Recovery time min. Short-circuit protection with fuse without TOR Coord. type "1" gL/gG (A) Coord. type “2” gL/gG (A) Without welding gL/gG (A) Impedance per pole (mΩ) Power dissipation per pole AC-1 (W) Insulation resistance Between adjacent poles (mΩ) Between poles and earth (mΩ) Between input and output (mΩ) CK07B CK08B 200 690 1000 200 25...400 1150 950 950 800 – 2100 1500 1150 750 550 350 10 1600 1600 1000 350 2500 2500 2300 1250 900 600 10 3500 3500 2200 1100 5500 3500 2500 1600 1200 900 10 3500 3500 2200 1100 5500 3500 2500 1600 1200 900 10 5600 5600 3500 2000 7500 5200 4000 2800 1800 1200 10 5600 5600 3500 2000 7500 5200 4000 2800 1800 1200 10 6700 6700 6000 3500 9700 7700 6100 4400 3500 2300 10 6600 6600 6000 3500 11600 8800 7350 5300 4500 2800 10 315 250 200 0.45 500 400 315 0.32 500 400 315 0.28 630 500 425 0.28 1250 630 500 0.15 1250 800 630 0.13 1250 1000 800 0.14 2x800 1250 1000 0.11 18 33.8 44.8 56.7 61.2 68.6 140 171.8 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 325 1000 1000 325 25...4000 1850 D E F G H I X C.43 Series CK Electrical endurance Mixed category AC4 / AC3 Electrical endurance for mixed category (AC-3/AC-4) is calculated with the following formula: Electrical endurance (AC-3/AC-4) Electrical endurance (AC-3) = 1 + Contactors Category AC1 Number of operations A B Ic=Ie for all voltages C D E Category AC2 Number of operations F G H I . X Rated motor power (Ic = 2.5 Ie) C.44 % oper AC-4 100 X (AC-3) -1 ) ( Elec.endur. Elec.endur.(AC-4) Series CK Electrical endurance (continued) Category AC3 Number of operations . 3P and 4P contactors Rated motor power (Ic = Ie) A B C Category AC4 D E Number of operations F G H . I Rated motor power (Ic = 6 Ie) X C.45 Series CK Three pole contactors. Control circuit Alternating current Contactors CK75CA CK08CA (V) 1000 1000 (V) 24...690 24...690 A B C D Rated insulation voltage Ui Standard voltages Us (50/60 Hz) Operating limits Switch-on xUs Switch-off xUs Consumption. Monofrequency coils Magnetic circuit CK....A (VA) closed CK....E (VA) Magnetic circuit CK....A (VA) open CK....E (VA) Power CK....A (W) dissipation CK....E (W) Consumption. Bifrequency coils Magnetic circuit 50Hz (VA) closed (CK....A) 60Hz (VA) Magnetic circuit 50Hz (VA) open (CK....A) 60Hz (VA) Power 50Hz (W) dissipation (CK....A) 60Hz (W) Power factor Magnetic circuit CK....A (cos ϕ) closed CK....E (cos ϕ) Magnetic circuit CK....A (cos ϕ) open CK....E (cos ϕ) Opening and closing times at Us Making time (ms) at excitation (NO) Breaking time (ms) at de-energisation (NO) Mechanical endurance 106 ops Maximum rate No load ops./h AC-1/AC-3 at rated power. ops./h AC-2 at rated power ops./h AC-4 at rated power ops./h 0.8...1.1 0.4...0.6 CK85BA CK85BE CK09BE CK95BE CK10CE CK11CE CK12BE CK13BA 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...440 0.8...1,1 0.4...0,6 0.8...1.1 0.4...0.6 0.8...1,1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.25...0.55 42 - 500 - 21 - 42 - 500 - 21 - 46 20 830 425 17 3.5 - 20 - 425 - 3.5 - 20 - 425 - 3.5 - 23 - 680 - 4 - 23 - 680 - 4 - 25 - 750 - 4.5 6 2760 5 - 46 38.3 568 473 23 19.1 46 38.3 568 473 23 19.1 60 50 1082 901 22.2 18.5 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.4 - 0.6 - 0.4 - 0.6 - 0.37 - 0.6 - - - - - - - - - - - - - - - - - - - - - approx. 1 approx. 1 - 20...25 20...25 36...40 60...70 60...70 80...90 80...90 70...80 50...55 10...13 10...13 10...15 13...17 13...17 40...50 40...50 70...80 115...130 10 10 10 10 10 10 10 10 3 2400 600 250 150 2400 600 250 150 2400 600 250 150 1200 600 250 150 1200 600 250 150 900 300 200 120 900 300 200 120 900 300 200 120 600 120 120 120 CK08CE CK85BE CK09BE CK95BE CK10CE CK11CE CK12BE Rated insulation voltage Ui Standard voltages Us (50/60 Hz) Operating limits Switch-on xUs Switch-off xUs Consumption Magnetic circuit closed (W) Magnetic circuit open (W) Opening and closing times at Us Making time (ms) at excitation (NO contacts) Breaking time (ms) at de-energisation (NO contacts) Mechanical endurance 106 ops. Maximum rate No load ops./h AC-3 at rated power ops./h AC-4 at rated power ops./h 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 0.8...1.1 0.4...0.6 E F G H I X C.46 Direct current CK75CE 1000 (V) (V) 24...500 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.35...0.5 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1,1 0.4...0,6 2 135 2 135 3.5 350 3.5 350 3.5 350 4 405 4 405 60...70 60...70 60...70 60...70 60...70 80...90 80...90 70...80 13...17 13...17 13...17 13...17 13...17 40...50 40...50 40...50 10 10 10 10 10 10 10 10 1200 600 150 1200 600 150 1200 600 150 1200 600 150 1200 600 150 900 300 120 900 300 120 900 300 120 4.5 650 Series CK Four pole contactors. Control circuit Alternating current 1000 24...690 0.8...1.1 0.4...0.6 CK08BA CK08BE CK09BE CK95BE CK10CE CK11CE CK12BE CK13BA 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 110...440 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.25...0.55 46 20 830 425 17 3.5 130 25 2860 750 53 4.5 - 25 - 750 - 4.5 - 25 - 750 - 4.5 - 23 - 680 - 4 - 23 - 680 - 4 - 25 - 750 - 4.5 6 2760 5 - 60 50 1082 901 22.2 18.5 159.3 132.7 3509 2924 65.3 54.4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.37 - 0.6 - 0.37 - 0.6 - - - - - - - - - - - - - - - - - - - - - approx. 1 approx. 1 - 36...40 60...70 70...80 70...80 110...115 80...90 110...115 50...55 10...15 13...17 70...80 70...80 70...80 40...50 70...80 70...80 10 10 10 10 10 10 10 3 2400 600 900 600 900 600 900 600 900 300 900 300 900 300 600 120 3P and 4P contactors Rated insulation voltage Ui (V) Standard voltages Us (50/60 Hz) (V) Operating limits Switch-on xUs Switch-off xUs Consumption. Monofrequency coils Magnetic circuit CK....A (VA) closed CK....E (VA) Magnetic circuit CK....A (VA) open CK....E (VA) Power CK....A (W) dissipation CK....E (W) Consumption. Bifrequency coils Magnetic circuit 50Hz (VA) closed (CK....A) 60Hz (VA) Magnetic circuit 50Hz (VA) open (CK....A) 60Hz (VA) Power 50Hz (W) dissipation (CK....A) 60Hz (W) Power factor Magnetic circuit CK....A (cos ϕ) closed CK....E (cos ϕ) Magnetic circuit CK....A (cos ϕ) open CK....E (cos ϕ) Opening and closing times at Us Making time (ms) at excitation (NO) Breaking time (ms) at de-energisation (NO) Mechanical endurance 106 ops. Maximum rate No load ops./h AC-1/AC-3 at rated power ops./h CK07BA CK07BE A B C D E Direct current F Rated insulation voltage Ui (V) Standard voltages Us (V) Operating limits Switch-on xUs Switch-off xUs Consumption. Magnetic circuit closed (W) Magnetic circuit open (W) Opening and closing times at Us Making time (ms) at excitation (NO contacts) Breaking time (ms) at de-energisation (NO contacts) Mechanical endurance 106 ops. Maximum rate No load ops./h AC-3 at rated power ops./h CK07BE 1000 24...500 0.75...1.1 0.4...0.6 CK08BE CK08BE CK95BE CK10CE CK11CE CK12BE 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 3.5 350 4.5 650 4.5 650 4.5 650 4.5 650 4.5 650 4.5 650 60...70 70...80 70...80 70...80 80...90 80...90 110...115 13...17 70...80 70...80 70...80 40...50 40...50 70...80 10 10 10 10 10 10 10 1200 600 900 600 900 600 900 600 900 600 900 300 900 300 G H I X C.47 Series CK Contact sequence Basic contactor Auxiliary contact blocks Lateral mounted BCLL 20 BRLL 20 BCLL 11 BRLL 11 Three-pole CK75C... contactors CK08C... 3 NO 0 CK85B... CK09B... CK95B... 0 10.4 14 0 CK10C... CK11C... 0 12 17 0 3.5 CK12B... CK13B... 0 12.6 17.5 0 3.5 17.5 0 3.5 CK07B... 0 7.7 0 10.7 0 CK08B... CK09B... CK95B... 0 10.4 14 CK10C... CK11C... 0 12 17 CK12B... CK13B... 0 7.3 10.4 0 3.5 10.4 0 3.5 10.4 1,8 3.5 14 0 3.5 14 1,8 17 0 3.5 17 Contactors 1.8 17.5 1.8 10.7 3.5 A 0 3.5 14 17 10.7 3.5 14 1.8 0 0 3.5 3.5 1.8 0 3.5 17 1.8 B 12.6 17.5 0 3.5 17.5 0 3.5 17.5 1.8 C Numbering of the terminals D E Three pole contactors Four pole contactors CK75C_ _3_ ... CK13B _ _3_ CK07B_ _4_ ... CK13B _ _4_ Auxiliary contact blocks. Lateral mounting Voltage suppressor block BCLL20 BCLL11 K/RC... BRLL20 BRLL11 Mechanical interlock F G H I X C.48 BEKV, BEKVA1, BEKVS1, BEKVH Series CK Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3P and 4P contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A B C D E F G H I X C.49 Series M Dimensional drawings Three and four pole minicontactors Screw terminal 0.170 kg MC_C_ _ _ AT◆ 0.210 kg MC_I _ _ _ ATD 0.225 kg MC_K_ _ _ ATD 0.225 kg Contactors Ring terminal 0.025 kg 0.040 kg Ring terminal MC_A_ _ _ AR◆ 0.170 kg A MACN2 _ _AT - MARN2 _ _AT MACN4 _ _AT - MARN4 _ _AT . . . Screw terminal . . MC_A_ _ _ AT◆ Auxiliary contact block. Lateral mounting . . MC_C_ _ _ AR◆ 0.210 kg MACN2 _ _AR - MARN2 _ _AR MACN4 _ _AR - MARN4 _ _AR 0.025 kg 0.040 kg . B Terminal: faston 2x2.8 insulated Terminal: faston 2x2,8 insulated C MC_A_ _ _ AF◆ 0.165 kg MC_C_ _ _ AF◆ 0.210 kg . . . D E G . . MC_A_ _ _ A I◆ 0.165 kg . . . . . . . . X C.50 . . . H I . Terminal: printed circuit . . F 0.035 kg 0.035 kg MACF4 _ _AF MARF4 _ _AF Drilling templates MC_C_ _ _ A I◆ 0.210 kg Series M Auxiliary contact blocks. Lateral mounting Screw terminal Electronic timer block MREBC _0AC2 . . . . (1) Frontal mounting (2) Lateral mounting (1) AC-control. (2) DC-control. Voltage suppressor block Ring terminal 0.013 kg 0.013 kg MACL_ _ _AR MARL_ _ _ARS MP0A_AE_ MP0C_AE3 0.010 kg 0.010 kg . . . 3P and 4P minicontactors 0.013 kg 0.013 kg MACL_ _ _AT MARL_ _ _ATS 0.040 kg A (1) AC-control. (2) DC-control. B Terminal: faston 2x2.8 insulated MACL _ _AF MARL _ _AFS 0.009 kg 0.009 kg C . . D E (1) AC-control. (2) DC-control. Terminal: printed circuit MACL _ _AI MARL _ _AIS . . . 0.009 kg 0.009 kg (1) AC-control. (2) DC-control. F G H I X C.51 Series CL Dimensional drawings. Three pole contactors Alternating current CL00A3...., CL01A3...., CL02A3.... CL25A3.... 0.280 kg 0.270 kg 0.280 kg 0.280 kg . . Types Terminal : ring terminal CL03A3...., CL04A3.... CL45A3.... 0.490 kg 0.520 kg 0.500 kg . . Types Terminal : ring terminal . . . . Contactors . . . . A Types Terminal : ring terminal B C Types Terminal : ring terminal CL06A3...., CL07A3...., CL08A3.... CL09A3...., CL10A3.... 1.105 kg 1.450 kg 1.120 kg 1.130 kg 1.470 kg . D E F G H I X C.52 . . Types Terminal : ring terminal Dimension in function of the thickness (ring terminal) . Types Terminal : ring terminal Dimension in function of the thickness (ring terminal) Series CL Three pole contactors Direct current CL00D3...., CL01D3...., CL02D3.... CL25D3.... 0.490 kg 0.480 kg 0.490 kg 0.490 kg . . . . Types Terminal : ring terminal CL03D3...., CL04D3.... CL45D3.... 0.480 kg 0.825 kg 0.835 kg . 3P and 4P contactors . . . Types Terminal : ring terminal . A . . . Types Terminal : ring terminal Types Terminal : ring terminal CL06D3...., CL07D3...., CL08D3.... CL09D3...., CL10D3.... 1.110 kg 1.440 kg 1.110 kg 1.110 kg C 1.440 kg D . Types Terminal : ring terminal Coil with electronic module E F G CL06E3...., CL07E3...., CL08E3.... CL09E3...., CL10E3.... 1.095 kg 1.440 kg 1.110 kg 1.120 kg Dimension in function of the thickness (ring terminal) Types Terminal : ring terminal Dimension in function of the thickness (ring terminal) . . B H 1.460 kg . . . I . X C.53 Series CL Dimensional drawings. Four pole contactors Alternating current CL01A4...., CL02A4...., CL01AB...., CL02AB.... CL03A4...., CL04A4...., CL03AB...., CL04AB.... 0.280 kg 0.490 kg 0.280 kg 0.280 kg 0.280 kg 0.500 kg . 0.490 kg 0.500 kg . . . . CL05A4...., CL07A4...., CL05AB...., CL07AB...., CL08AB... CL09A4.... 1.240 kg 1.450 kg 1.270 kg D 1.240 kg 1.270 kg 1.270 kg . Types Terminal : ring terminal B C Types Terminal : ring terminal . A Types Terminal : ring terminal . Contactors . Types Terminal : ring terminal Dimension in function of the thickness (ring terminal) Dimension in function of the thickness (ring terminal) Direct current CL01D4...., CL02D4...., CL01DB...., CL02DB.... CL03D4...., CL04D4...., CL03DB...., CL04DB.... 0.490 kg 0.825 kg 0.490 kg 0.490 kg 0.490 kg . 0.835 kg . 0.825 kg 0.835 kg . F . . . E Types Terminal : ring terminal Types Terminal : ring terminal G CL09D4.... CL05D4...., CL07D4...., CL05DB...., CL07DB...., CL08DB... 1.290 kg 1.290 kg . I X C.54 . . Types Terminal : ring terminal . . . Types Terminal : ring terminal Dimension in function of the thickness (ring terminal) 1.290 kg Dimension in function of the thickness (ring terminal) H 1.290 kg Series CL Four pole contactors Coil with electronic module CL05E4...., CL07E4...., CL05EB...., CL07EB...., CL08EB... CL09E4.... 1.290 kg 1.500 kg 1.290 kg 1.290 kg 1.320 kg 1.320 kg . 3P and 4P contactors . . A B C D E F G H I X C.55 Series CL Dimensional drawings Auxiliary contact blocks Screw terminal Accessories Voltage suppressor block BCLF... 0.015 kg BSLR, BSLDZ, BSLV 0.020 kg . . Contactors CL00 ... CL25 BCLL..., BRLL.... 0.048 kg . CL03 ... CL45 A B BTLF... 0.085 kg . C CL05 ... CL10 D Mechanical latch block E RMLF 0.082 kg Ring terminal F BCRF... 0.015 kg . . G H Mechanical / mechanical-electrical interlock I BEL, BELA, BEL02, BELA02 BTRF... X C.56 0.085 kg . 0.025 kg Series CL Electronic timer block BETL02, BETL45 0.040 kg Interface modules IMR..., IMRF..., IMSSD, IMAMS CL00 ... CL25 CL03 ... CL45 CL03 ... CL45 3P and 4P contactors CL00 ... CL25 0.020 kg A B C CL05 ... CL10 CL05 ... CL10 D E F G H I X C.57 Series CK Dimensional drawings Three pole contactors . 3.500 kg 3.500 kg . . Contactors . . CK75C CK08C CK85B CK09B CK95B 6.100 kg 6.200 kg 6.300 kg CK10C CK11C 11.00 kg 11.00 kg A B C D E CK12B 18.00 kg F G H I X C.58 CK13B 35.00 kg . Series CK Four pole contactors CK07B Mechanical interlock . 4.700 kg BEKH 0.350 kg CK08B CK09B CK95B 14.90 kg 15.10 kg 15.30 kg CK10C CK11C A 55 55 33 75 BEKVA1 BEKVS1 22.30 kg 22.80 kg A 3P and 4P contactors CK75C3... - CK08C3... CK85B3... - CK95B3... CK10C3... - CK11C3... CK12B3... A 550 0.900 kg 350 0.800 kg B C D CK12B E 23.30 kg F BEKV 1.200 kg G H CK13B I 44.00 kg X . . C.59 Series MTO Thermal overload relays for minicontactors from 0.11 to 14A Thermal overload relays • Control circuit up to 690V • Power circuit up to 690V • Three-pole differential (phase unbalance protection) • Automatic ambient temperature compensation between – 25ºC and + 60ºC • Choice of manual or automatic reset • Direct connection to contactor or independent mounting using accessories. • Screw and Ring terminal versions • Terminals protected against accidental contact in accordance with VDE 0106 T.100 and VBG4. • Terminal numbering in accordance with EN 50005 • Degree of protection IP20 (EN 60529) • Additional auxiliary contact block 1NO (with manual reset only) General characteristics A Standards B IEC/EN 60947-4-1 IEC/EN 60947-5-1 UNE 115 NFC 63-650 CSA 22.2/14 NI C 63-650 VDE 0660 UL 508 C D Approvals E cULus NEMKO SEMKO SETI CE F G H I X Order codes ! pg. C.61 Technical data ! pg. C.68 Dimensions ! pg. C.69 C.60 • Thermal protection against balanced overload. • Three-pole differential (phase unbalance protection). • Automatic ambient temperature compensation. • Front mounted selector for choosing utilisation current. • Reset button, 2 positions : Manual(H) and Automatic(A) by turning the blue selector. • Stop push button, independent of reset (red). • Manual trip lever (tripping test). • Tripping indicator (0-1). • To facilitate wiring arrangements terminal 96 fits directly onto coil terminal (A2) and terminal 14/22 fits directly onto the feedback auxiliary contact. Series MTO Thermal overload relays for minicontactors For use with: Setting range (regulation) min. MC0... MC1... MC2... A 0.11 0.17 0.26 0.43 0.65 0.85 1.1 1.35 1.7 2.2 2.5 3 4 5.5 7.5 10 gL Type 2 Type 1 Type 2 Type 1 max. A A A A A 0.17 0.5 0.5 0.5 0.5 0.26 0.85 1 1 1 0.43 1 2 2 4 0.65 1 4 2 8 1 2 6 4 12 1,3 2 6 4 12 1.6 2 10 4 16 2 4 10 6 16 2.4 4 16 6 25 3.2 4 20 6 32 4 4 20 6 32 4.7 6 20 10 32 6.3 10 32 16 50 8 12 50 20 63 10.5 16 50 25 80 14 20 32 32 100 Terminal: screw Pack Terminal: ring terminal Cat. no. Ref. no. Cat. no. Ref. no. MT03A MT03B MT03C MT03D MT03E MT03F MT03G MT03H MT03I MT03J MT03R MT03K MT03L MT03M MT03N MT03P 101000 101001 101002 101003 101004 101005 101006 101007 101008 101009 101015 101010 101011 101012 101013 101014 MT03RA 103540 MT03RB 103541 MT03RC 103542 MT03RD 103543 MT03RE 103544 MT03RF 103545 MT03RG 103546 MT03RH 103547 MT03RI 103548 MT03RJ 103549 MT03RK 103550 MT03RL 103551 MT03RM 103552 MT03RN 103553 MT03RP 103554 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Accessories Input terminals Base For separate mounting onto standard EN 50022-35 profile Terminal Cat. no. Ref. no. Pack Screw MVE0T 101020 5 Ring terminal MVE0R 103562 5 MVB0T 101021 5 Order codes Fuse aM A B C D Auxiliary contact block Identification Frontal fixing to the relay With trip indicator (0-I) One block per relay and only for manual reset Sheets of labels (sheets of 260 labels each) Labeling plate base (50 pieces in one pack) E Screw Ring terminal MATV10AT 101022 10 MATV10AR 103563 10 F EAT 260 100548 1 SPR 100549 1 G H I X C.61 Series RT Thermal overload relays for contactors from 0.16 to 850A Thermal overload relays • Control circuit up to 690V AC • Power circuit: - RT1, RT12: up to 690V - RT2, RT22, RT3, RT32, RT4/4L, RT5/5L & RT6/6L: up to 1000V • Thermal protection against normal overloads. • Three pole differential (phase unbalance protection). • Protection against long starting times. • Automatic ambient temperature compensation between – 25ºC y + 60ºC. • Front mounted test button. • Trip indication. • Independent auxiliary contacts with double rupture (1NO + 1NC). • Function selector: - Manual RESET - Manual RESET and STOP - Automatic RESET with STOP - Automatic RESET without STOP A B Standards IEC/EN 60947-4-1 IEC/EN 60947-5-1 UNE 115 NFC 63-650 CEI 17-50 CSA 22.2/14 NI C 63-650 VDE 0660 UL 508 C D E Manual RESET and STOP Approvals Automatic RESET without STOP cULus CE Lloyd’s Register Bureau Veritas Automatic RESET with STOP F G RINA H I X Order codes ! pg. C.63 Technical data ! pg. C.70 Dimensions ! pg. C.74 C.62 Manual RESET Series RT Thermal overload relays for contactors For use with: Setting range (regulation) Fuses (1) aM gL - gG min. A max. A A A Srew terminal Ring terminal Pack Cat. no. Ref. no. Cat. no. Ref. no. CL00 CL01 CL02 CL25 CL03 CL04 CL45 0.16 0.25 0.4 0.65 1.0 1.3 1.8 2.5 4.0 5.5 8.0 10.0 14.5 17.5 21.0 25.0 30.0 0.26 0.41 0.65 1.1 1.5 1.9 2.7 4.0 6.3 8.5 12.0 16.0 18.0 22.0 26.0 32.0 40.0 2 2 2 2 4 4 6 8 12 16 20 25 32 40 40 50 63 2 2 2 4 6 6 10 16 20 20 25 35 50 50 63 80 100 RT1B RT1C RT1D RT1F RT1G RT1H RT1J RT1K RT1L RT1M RT1N RT1P RT1S RT1T RT1U RT1V RT1W 113700 113701 113702 113703 113704 113705 113706 113707 113708 113709 113710 113711 113712 113713 113714 113715 113716 RT1RB RT1RC RT1RD RT1RF RT1RG RT1RH RT1RJ RT1RK RT1RL RT1RM RT1RN RT1RP RT1RS RT1RT RT1RU RT1RV RT1RW 114087 114088 114089 114090 114091 114092 114093 114094 114095 114096 114097 114098 114099 114100 114101 114102 114103 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Class 10 CL05 CL06 CL07 CL08 CL09 CL10 11.5 14.5 18.5 24.0 30.0 42.0 54.0 64.0 78.0 90.0 15.0 19.0 25.0 32.0 43.0 55.0 65.0 82.0 97.0 110 32 40 50 63 80 100 125 125 125 160 35 50 63 100 125 160 160 200 200 250 RT2A RT2B RT2C RT2D RT2E RT2G RT2H RT2J RT2L RT2M 113717 113718 113719 113720 113721 113722 113723 113724 113725 113726 RT2RA RT2RB RT2RC RT2RD RT2RE RT2RG RT2RH RT2RJ RT2RL RT2RM 114104 114105 114106 114107 114108 114109 114110 114111 114112 114113 1 1 1 1 1 1 1 1 1 1 CL00 CL01 CL02 CL25 CL03 CL04 CL45 0.4 0.65 1 1.3 1.8 2.5 4 5.5 8 10 14.5 17.5 21 25 30 0.65 1.1 1.5 1.9 2.7 4.1 6.3 8.5 12 16 18 22 26 32 40 2 2 4 4 8 8 12 16 20 25 32 40 40 50 63 2 4 6 6 10 16 20 20 35 35 50 50 63 80 100 RT12D RT12F RT12G RT12H RT12J RT12K RT12L RT12M RT12N RT12P RT12S RT12T RT12U RT12V RT12W 139138 139139 139140 139141 139142 113640 113641 113642 113643 113644 113645 113646 113647 113648 113649 RT12RD RT12RF RT12RG RT12RH RT12RJ RT12RK RT12RL RT12RM RT12RN RT12RP RT12RS RT12RT RT12RU RT12RV RT12RW 114060 114061 114062 114063 114159 114114 114115 114116 114117 114118 114119 114120 114121 114122 114123 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 24 30 42 54 64 78 90 32 43 55 65 82 97 110 63 80 100 125 125 125 160 80 100 160 160 200 200 250 RT22D RT22E RT22G RT22H RT22J RT22L RT22M 113650 113651 113652 113653 113654 113655 113656 RT22RD RT22RE RT22RG RT22RH RT22RJ RT22RL RT22RM 114124 114125 114126 114127 114128 114129 114130 1 1 1 1 1 1 1 Class 20 CL05 CL06 CL07 CL08 CL09 CL10 Order codes Class 10A A B C D E F G (1) Most suitable fuse in accordance with IEC 60947-4-1. H I X C.63 Series RT Thermal overload relays for contactors For use with: Setting range (regulation) Fuses (1) aM gL - gG Cat.no. Ref. no. Pack (Screw terminal) min. A 55 CK75 63 CK08 Direct mounting 90 110 140 Thermal overload relays Class 10 A X C.64 113727 113728 113729 113730 113731 1 1 1 1 1 120 175 200 190 280 310 250 315 400 315 400 500 RT4N RT4P RT4R 113732 113733 113734 1 1 1 CK10 CK11 CK12 (3) 120 175 250 315 430 190 280 400 500 700 250 315 500 630 800 315 400 630 800 1000 RT5A RT5B RT5C RT5D RT5E 113750 113751 113752 113753 113754 1 1 1 1 1 CK13 (4) 500 850 100 1250 RT6A 113760 1 63 CK75 90 CK08 Direct mounting 110 140 90 120 140 190 125 160 200 250 200 250 315 355 RT32C RT32D RT32E RT32F 113657 113658 113659 113660 1 1 1 1 Class 20 Class 30 CL... CK... Mounting with screws CK85 CK09 CK95 (2) 2.5 4 5.5 7.5 10 12.5 17 26 32 45 60 80 120 175 200 4 6.5 8.5 11 16 20 27 40 52 70 90 125 190 280 310 10 12 16 20 25 32 50 80 100 125 160 200 250 315 400 16 20 25 32 40 50 80 125 160 160 200 250 315 400 500 RT4LA RT4LB RT4LC RT4LD RT4LE RT4LF RT4LG RT4LH RT4LJ RT4LK RT4LL RT4LM RT4LN RT4LP RT4LR 113735 113736 113737 113738 113739 113740 113741 113742 113743 113744 113745 113746 113747 113748 113749 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CK10 CK11 CK12 (3) 120 175 250 315 430 190 280 400 500 700 250 315 500 630 800 315 400 630 800 1000 RT5LA RT5LB RT5LC RT5LD RT5LE 113755 113756 113757 113758 113759 1 1 1 1 1 CK13 (4) 500 850 1000 1250 RT6LA 113761 1 E I RT3B RT3C RT3D RT3E RT3F D H A 200 200 250 315 355 CK85 CK09 CK95 (2) C G A 125 125 160 200 250 B F max. A 80 90 120 140 190 (1) (2) (3) (4) Most suitable fuse in accordance with IEC 60947-4-1. Fitting direct to the contactor. Fitting direct to the contactor: by means of a coupling and connection set. Separate mounting:with screws on DIN rail / with cable connection. RT6A = RT1 with right setting range plus RTXP, independent mounting base adaptor, to be utilisied with current transformer connected by passing cable chosen by customer. Current transformer data on request. SeriesRT Accessories Cat. no. Base for separate mounting Setting range cover protection Terminal protection DIN EN50022-35 RT1 RT2 RTXP RT2XP 105170 113764 1 1 RT... RTX3 113762 1 0.5meters 1meters RTXS RTXSL RTXBS 113855 113856 108864 1 1 1 PTPCK75 RT3PXX3P 103747 110565 1 1 fordistanceRESET RT1...-RT6....(front) RT1...-RT6....(front) RT1...,RT2...,RT4...,RT5...,RT6...(back) forRT3orCK75C/CK08C Thermaloverloadrelay Connectioncontactor-relay 1poleIPxxB 3poles Order codes Push-button with flexible cable Ref. no. Pack A B Remote electrical reset RT1...-RT6... RTXRR ◆ 1 C D E Available coil voltages (V) © B AC/DC 12 D G J N U X 24 48 110 220 380 440 240 415 480 F G H I X C.65 Series RE NEW Electronic overload relay Electronic overload relay Approvals A B cULus CE C Product features Your benefits Lower power consumption Saving space into cabinet Great accuracy Better motor protection Full reliability Low risk to burn motor Phase unbalance protection Better motor protection and current control Direct fitting to contactors Series CL Compact starter Interchangeable with thermal overload relay No need to redesign existing cabinet Multiple trip class selection One device cover for start time motor E Manual / Auto reset One device for two solutions F Main characteristics D • Setting range from 0.1 up to 150A • Self powered • Thermal memory • Phase loss protection • Phase unbalance protection • Direct fitting to contactors Series CL • Interchangeable with thermal overload relay • Multiple trip class selection • Manual / Auto reset • Increased flexibility, less order codes, less stock • Tripp class: 5 - 10 - 20 - 30 G H I X Order codes ! pg. C.67 Technical data ! pg. C.76 Dimensions ! pg. C.78 C.66 Series RE Electronic overload relay for contactors Setting range (A) Fuses (A) (1) Min. Max. gL - gG Cat. no. Ref. no. Pack. Frame 1 CL00…CL45 0,1 0,4 1,0 1,6 6,4 9,0 0,5 2 5 8 32 45 2 4 10 20 63 80 RE1D RE1H RE1K RE1M RE1S RE1W 101866 101867 101868 101869 101870 101871 5 5 5 5 5 5 Frame 2 CL05…CL10 15 22 75 110 125 125 RE2H RE2M 101872 101873 1 1 Frame 3 CK75-CK08 30 150 250 RE3E 101874 1 Order codes Suitable for A B Accessories Independent mounting base adaptor Frame 1 Cat. no. Ref. no. Pack. RE1XP 247302 1 C D Independent mounting base adaptor Frame 2 (1) Most suitable fuse in accordance with IEC 60947-4-1, see coordination table on pg. C.76. RE2XP 247303 1 E F G H I X C.67 Series MTO Technical data Thermal overload relays General A Mounting positions • Thermal protection against balanced overload. • Three-pole differential ( phase unbalance protection). • Automatic ambient temperature compensation. • Front mounted selector for choosing utilisation current. • Reset button, 2 positions : Manual(H) and Automatic(A) by turning the blue selector. • Stop push button, independent of reset (red). • Manual trip lever (tripping test). • Tripping indicator (0-1). • To facilitate wiring arragements terminal 96 fits directly onto coil terminal (A2) and terminal 14/22 fits directly onto the feedback auxiliary contact. MT0... Conformity to standards IEC 60947-4 UNE 115 NFC63-650 CEI 17-50 NI C63-650 UL SETI CSA NEMKO Ambient conditions C Storage temperature Operation temperature Altitude up to 3000m from 3000 to 4000m from 4000 to 5000m Degree of protection Protection treatment E F G H I X C.68 VDE660 UL508 Approvals B D Main circuit (poles) SEMKO CE -55ºC to +80ºC -25ºC to +60ºC Nominal values 90%Ie 80%Ue 80%Ie 75%Ue IP20 Tropical finish Climatic resistance Continuous tests 40 / 125 / 56 Cold (72h) Temperature Dry heat (96h) Temperature Relative humidity Humid heat (56 days) Temperature Relative humidity Cyclical tests First half-cycle (12h) Low temperature Relative humidity Second half-cycle (12h) Low temperature Relative humidity Number of consecutive cycles -40ºC Rated insulation voltage (Ui) (V) 750 according to IEC 947 Frequency (Hz) 0...400 Power dissipation per pole (W) min. 1 / max. 2.5 Terminal capacity Screw M 3.5 (pozidrive head) safety flange Maximum capacity : Solid (Ø mm) 2 x 2 wires Stranded without end sleeve (mm2) 2 wires Ø 2.5 Stranded with end sleeve pen (2 end sleeves) (mm2) 2 wires Ø 0.75 pen (1 end sleeve) (mm2) 2 wires Ø 1 1 wires Ø 2.5 Tightening torque (Nm) 0.8 Control circuit (incorporated auxiliary contact) MT0... Rated insulation voltage (Ui) according to IEC 947 Rated thermal current (Ith) θ ≤ 60ºC Tripping currents AC-15 Ue-Ie DC-13 Ue-Ie Short-circuit protection (max.glass gL fuse - w/h welding) Number and type of contacts (V) 750 (A) 10 (V-A) (V-A) (A) 223-3, 380-2, 500-1 60-0.5, 110-0.2, 220-0.1 6 +125ºC < 50% +40ºC 95% +25ºC 93% Control circuit +55ºC 95% 6 Rated insulation voltage (Ui) according to IEC 947 Rated thermal current (Ith) θ ≤ 60ºC Tripping currents AC-15 Ue-Ie DC-13 Ue-Ie Short-circuit protection (max.glass gL fuse - w/h welding) Number and type of contacts (auxiliary contact block) MATV10AT (V) 750 (A) 10 (V-A) (V-A) (A) 223-1, 380-0.5 60-0.1, 110-0.5 6 Series MTO Dimensional drawings Numbering of the terminals Thermal overload relay MT0... . . 0.091 kg Trip Time (s) Thermal overload relay + aux. contact block (front mounting) Technical data Tripping curves A Single phase Cold state B Three phase Cold state C Independent mounting of the thermal overload relay D Three phase Warm state . E . . . . Multiples of setting current . F . . G H I X C.69 Series RT Technical data RT1... RT2... RT3... RT4.../ 4L... RT5.../ 5L... RT6.../ 6L... General Thermal overload relays Class Setting range(A) Suitable for A B C 10A / 20 0.16 ... 40 CL00...CL45 10 / 20 11.5 ... 110 CL05...CL10 10 / 20 55 ... 190 CK75...CK08 10 / 30 2.5 ... 310 CL,CK 10 / 30 120 ... 700 CK10...CK12 10 / 30 500 ... 850 CK13 690 1000 1000 1000 1000 1000 0...400 0...400 0...400 50...60 50...60 50...60 16 10 - - - 2.5 50 50 - - - 4.5 120 120 25 x 5 - - 6.5 - - - - 30 x 10 23 - - - 400 30 x 10 31.5 80 x 10 - Main circuit Rated insulation voltage (V) (IEC947-4) Ui Frequency limits (Hz) Terminal capacity Clamp terminal - solid(mm2) Clamp terminal - flexible(mm2) Flat terminal (mm) Passing by hole (wire) through C.T. core (mm2) Passing by hole (bar) through C.T. core (mm) Tightening torque (Nm) Control circuit Rated insulation voltage (V) (IEC60947-4) Ui Rated thermal current Ith (A) Operation current AC-15 - Ue-Ie (V - A) DC-13 - Ue-Ie (V - A) Utilisation according UL and CSA Protective fuse type gL (A) Terminal capacity (mm2) Tightening capacity (Nm) 690 10 110/120 - 3 ; 220/240 - 2 ; 380/415 - 1 ; 480/500 - 0,8 ; 660/690 - 0,3 24 - 2 ; 48 - 1.4 ; 110 - 0.6 ; 250 - 0.3 ; 440 - 0.1 B600 - Q600 10 2.5 0.8 Remote electrical reset Conformity to standards IEC/EN 60947-4-1 IEC/EN 60947-5-1 UNE 115 NFC 63-650 CEI 17-50 CSA 22.2/14 NI C 63-650 VDE 0660 UL 508 D Power consumption AC (VA) DC (W) Coils not suitable for continuous operating duty Approvals E F G cULus LLoyd’s Register RINA Bureau Veritas Ambient conditions Storage temperature Operation temperature (compensated) Altitude up to 3000m Relative humidity Protection treatment H Mounting positions I X C.70 CE -40ºC to +70ºC -25ºC to +60ºC w/o any changes in characteristics 98% Tropical finish t1 = 1 sec. t1 = 5 sec. t1 = 10 sec. ♦ ♦ ♦ t2 = 30 sec. t2 = 90 sec. t2 = 180 sec. (t1 = ON timet2 = OFF time) 100 100 Series RT Tripping curves RT1 Class 10A RT2 Class 10 Trip Time (s) Trip Time (s) Single phase Cold state Three phase Cold state Three phase Cold state Technical data Single phase Cold state A Three phase Warm state . Three phase Warm state . . B . . . Multiples of setting current RT12 Class 20 Multiples of setting current RT22 Class 20 Trip Time (s) C D Trip Time (s) E F Single phase Cold state Single phase Cold state Three phase Cold state Three phase Cold state G H I Three phase Warm state . Three phase Warm state X . . . . . Multiples of setting current Multiples of setting current C.71 Series RT Tripping curves RT3 Class 10 RT4 Class 10 Trip Time (s) Thermal overload relays Trip Time (s) Single phase Cold state Single phase Cold state Three phase Cold state Three phase Cold state A B Three phase Warm state . . . . . . Multiples of setting current C D Three phase Warm state RT32 Class 20 Multiples of setting current RT4L Class 30 Trip Time (s) Trip Time (s) E F G Single phase Cold state Single-phase Cold state Three phase Cold state H Three phase Cold state I X Three phase Warm state . Three phase Warm state . . . Multiples of setting current C.72 . . Multiples of setting current Series RT Tripping curves RT5 Class 10 RT6 Class 10 Trip Time (s) Trip Time (s) Single phase Cold state Three phase Cold state Three phase Cold state Technical data Single phase Cold state A Three phase Warm state Three phase Warm state . . . B . . . Multiples of setting current RT5L Class 30 Multiples of setting current RT6L Class 30 Trip Time (s) C D Trip Time (s) E F G Single phase Cold state Single phase Cold state Three phase Cold state Three phase Cold state H I Three phase Warm state Three phase Warm state X . . . . . . Multiples of setting current Multiples of setting current C.73 Series RT Dimensional drawings Thermal overload relay for contactors RT1 - RT12 RT1 + RT XP RT12 + RTXP . . . . . . . RT2 - RT22 0.400 kg RT2 + RT XP RT22 + RTXP . . . . . A . . . Thermal overload relays 0.190 kg B . C RT3 - RT32 D 0.900 kg . F . E H I X C.74 . G . Series RT Thermal overload relay for contactors RT4LA...RT4LM 2.400 kg . . Dimensions RT4/4LN...RT4/4LR 2.400 kg A B . . C D RT5 / 5L 0.875 kg . E F G H . I Remote electrical reset RTXRR + ... RT1 RT2 RT3 RT4 RT5 X 75 84 108 150 200 Z 110 121 153 240 196 X C.75 Series RE Coordination tables Coordination Type 2 - 65kA at 380/400V and 415V - 50/60Hz MOTOR(1) Rated current Electronic overload relays Rated power A B (kW) 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 8.8 11 15 11 15 18.5 22 30 35 45 55 55 75 380/400V (A) 0.23 0.34 0.44 0.65 0.9 1.25 1.6 2 2.6 3.5 5 7 9 12 16 22.5 30 22.5 30 37 44 60 65 85 105 138 415V 0.21 0.31 0.4 0.63 0.8 1.1 1.5 1.9 2.5 3.4 4.5 6.5 8 11 14 21 28 21 28 35 40 -55 60 80 100 135 BREAKER CONTACTOR Rated Magnetic setting Magnetic Series current 1m current In Pick-up ±20% Im # (A) (A) (A) GPS1MHAB 0.25 3.3 CLOO GPS1MHAC 0.4 5.2 CLOO GPS1MHAD 0.63 8.2 CLOO GPS1MHAE 1 13 CLOO GPS1MHAE 1 13 CLOO GPS1MHAF 1.6 20.8 CLOO GPS1MHAF 1.6 20.8 CLOO GPS1MHAG 2.5 32.S CLOO GPS1MHAH 4 52 CL25 GPS1MHAH 4 52 CL25 GPS1MHAJ 6.3 81.9 CL25 GPS1MHAK 10 130 CL25 GPS1MHAK 10 130 CL25 GPS1MHAL 13 169 CL25 GPS1MHAM 16 208 CL25 GPS1MHAM 16 208 CL25 GPS1MHAP 25 325 CL25 GPS1MHAR 32 416 CL04 GPS2MHAR 25 325 CL04 GPS2MHAP 32 416 CL04 GPS2MHAS 40 520 CL45 GPS2MHAT 50 650 CL06 GPS2MHAT 50 650 CL06 GPS2MHAU 63 819 CL07 FDH36MC080GD 80 900-1300 1100 CL08 FDH36MC1 OOGD 100 1000-1500 1400 CL09 FDH36MC1 OOGD 100 1000-1500 1400 CL10 FEH36MC125JF 125 1250-1875 1250 CL10 FEH36MC200KF 200 2250-3350 2800 CK75 Cat. no. OVERLOAD RELAY Series Setting range RE1D RE1D RE1D RE1H RE1H RE1H RE1H RE1K RE1K RE1K RE1K RE1M RE1S RE1S RE1S RE1S RE1S RE1S RE1S RE1S RE1W RE2H RE2H RE2H RE2H RE2M RE2M RE2M RE3E (A) 0.1-0.5 0.1-0.5 0.1-0.5 0.4-2.0 0.4-2.0 0.4-2.0 0.4-2.0 1.5-5.0 1.5-5.0 1.5-5.0 1.5-5.0 1.6-8.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 9.0-45.0 15.0-75.0 15.0-75.0 15.0-75.0 15.0-75.0 22.0-110.0 22.0-110.0 22.0-110.0 30.0-150.0 WIRE Smallest wire Min frontal safety Cu (PVC)(2) (mm2) 1 1 1 1 1 1 1 1 1 1 1 1.5 1.5 2.5 2.5 2.5 4 6 4 6 10 10 10 16 25 25 25 25 50 (mm) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 25 25 25 25 30 30 30 40 Coordination Type 2 - 100kA at 500 - 525V - 50/60Hz C D E F G H I X Rated power kW 0.06 0.03 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 1.1 1.5 2.2 1.5 2.2 3 4 5.5 7.5 10 11 15 18.5 4 5.5 7.5 11 15 18.5 22 18.5 22 30 37 40 45 55 75 30 MOTOR(1) Rated current 500V 525V (A) 0.17 0.16 0.24 0.22 0.33 0.3 0.48 0.46 0.66 0.64 0.3 0.85 1.2 1.15 1.5 1.45 2.1 1.3 2.8 2.6 2.1 1.3 2.8 2.6 3.3 3.6 2.8 2.6 3.3 3.6 5.3 5 6.8 6.5 3.1 8.6 12 11.4 15.5 14.8 17.6 17 23 22 28.5 27 6.8 6.5 3.1 8.6 12 11.4 17.6 17 23 22 28.5 27 33 31.5 28.5 27 33 31.5 45 43 53 52 53 56 65 62 80 76 105 100 130 124 gL/gG Fuses Size In (A) 2 2 2 2 2 4 4 4 6 10 6 10 10 10 10 16 20 25 32 40 40 50 63 20 25 32 40 50 63 80 63 80 80 100 100 125 125 160 250 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 00 00 01/1 01/1 Series RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE1 RE2 RE2 RE2 RE2 RE2 RE2 RE2 RE3 RE3 EOL Type D D D D H H H H K K K K K K K M M S S S S S S M S S S S W H H H H H H H M E E Setting range (A) 0.1-0.5 0.1-0.5 0.1-0.5 0.1-0.5 0.4-2.0 0.4-2.0 0.4-2.0 0.4-2.0 1.5-5.0 1.5-5.0 1.5-5.0 1.5-5.0 1.5-5.0 1.5-5.0 1.5-5.0 1.6-8.0 1.6-8.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 1.6-8.0 6.4-32.0 6.4-32.0 6.4-32.0 6.4-32.0 3.0-45.0 15.0-75.0 15.0-75.0 15.0-75.0 15.0-75.0 15.0-75.0 15.0-75.0 15.0-75.0 22.0-110.0 30.0-150.0 30.0-150.0 CONTACTOR Series PAC3 CLOO CLOO CLOO CLOO CLOO CLOO CLOO CLOO CLOO CLOO CL01 CL01 CL01 CL25 CL25 CL25 CL25 CL25 CL25 CL25 CL25 CL04 CL04 CL45 CL45 CL45 CL45 CL45 CL45 CL45 CL06 CL06 CL06 CL07 CL08 CL09 CL10 CK75 CK08 (kW) 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 7.5 7.5 7.5 15 15 15 15 15 15 15 15 18.5 18.5 25 25 25 25 25 25 25 30 30 30 40 45 55 65 100 110 Seco min WIRE Safety clearance 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.5 2.5 2.5 2.5 4 6 1.5 2.5 2.5 2.5 4 5 5 5 5 10 10 16 16 25 35/25 50 (mm) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 25 25 25 25 25 30 30 40 40 (1) Current are relevant to four pole motors not having special characteristics of torque. (2) The minimum cycle cross-sections are referred to an ambient temperature of 30ºC max. in free air and are selected to withstand the maximum let-through energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature if it is different. C.76 Series RE Tripping curves Class 5 Class 10 Trip Trip Time Time (s) (s) Trip Trip Time Time (s) (s) Class 10 Trip Curve FLA Class 5 Trip CurveFLA 1.000 1.000 Class 10 Cold status Class 5 Cold status 100 10 10 Technical data 100 Class 10 Hot status Phase loss and Phase unbalance Hot status 1 Phase loss and Phase unbalance Hot status 1 A Class 5 Hot status 0.1 0.1 0 1 2 3 4 5 6 7 8 B 0 1 2 3 4 5 6 7 8 Multiples FLA Multiples FLA Multiples FLA Multiples FLA Class 20 Class 30 Trip Time Time (s) (s) Trip Trip Time Time (s) (s) Trip Class 20 Trip Curve FLA C D Class 30 Trip Curve FLA 1.000 E 1.000 Class 30 Cold status Class 20 Cold status 100 F 100 G 10 10 H Class 30 Hot status Class 20 Hot status I Phase loss and Phase unbalance Hot status 1 Phase loss and Phase unbalance Hot status 1 X 0.1 0 1 2 Multiples FLAFLA Multiples 3 4 5 6 7 8 0.1 0 1 2 3 4 5 6 7 8 Multiples FLAFLA Multiples C.77 C.78 49 49 49 110 123 98 110 123 67 67 38 38 38 38 98 49 110 123 X 98 49 49 107 111,5 C 1,5 67 45 107 111,5 6 T3 38 1,5 4 T2 30 1,5 6 T3 107 111,5 24,7 57,5 45 148,7 6 T3 154,2 4 T2 33 69 37,8 69 37,8 57,5 79,9 79,9 85,5 85,5 65 148,7 21 33 69 24,7 79,9 85,5 37,8 57,5 9 148,7 38 4 T2 8 111,7 21 9 9 154,2 21 8 8 111,7 15 45 9 154,2 15 9 8 111,7 15 24,7 15 8 131,2 B 83,5 Frame 2 9 131,2 2 T1 21 8 131,2 16 83,5 21 15 151,7 83,5 33 21 151,7 F 3 44,5 6 170 2 T1 92,5 2 T1 12 151,7 H 3 44,5 14,1 15 3 44,5 12 170 47,9 E 14,1 92,5 Frame 3 110 D 45 12 170 53,6 6 14,1 92,5 47,9 16 30 110 I 53,6 47,9 G 110 A 30 53,6 Electronic overload relays Series RE Dimensional drawings Frame 1 45 6 65 65 45 16 Series RE Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A B C D E F G H I X C.79 Series CSCN Contactors for capacitors switching Contactors for capacitors switching With built-in resistance to switch three phase capacitor banks “CSCN” contactors incorporate a front block with three early-make auxiliary contacts together with 6 quick discharge resistors (two per phase) through which the capacitors are switched to the network, reducing the current peak. Once the resistors have damped the current peak, the main contacts shortcircuit the resistors, carrying the uninterrupted current. A few miliseconds later the early-make auxiliary contact closes to guarantee that all current flows through the main contacts. Standards / Marking A B C IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 EN 50005 UL 508 CSA C22.2/14 CENELEC HD 419 VDE 0660/102 NFC 63-110 ASE 1025 UNE 20109 Standard voltages To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit, other voltages on request. Alternating current (V). Dual-frequency © 1 2 3 4 5 6 7 8 9 50/60Hz 24 42 110120220230240440 48 115 Approvals Alternating current (V) D © E K L N T U W Y Z 50Hz 32 127 220 380415500660 230 400 690 cULus CE E F G H I X Order codes ! pg. C.81 Technical data ! pg. C.82 Dimensional drawings ! pg. C.84 C.80 NEW 60Hz 208277380480460600 Series CSCN Contactors for capacitors switching Ambient temperature Contacts θ ≤ 70ºC θ ≤ 55ºC 3 • •1 230V 400V 415V 500V 660V 230V 400V 415V 500V 660V 690V Fuse 240V 690V 240V A kvar kvar kvar kvar kvar kvar kvar kvar kvar kvar gl - gG 4 •2 • 25 2 25 7.5 12.5 13 0 16 15 3.7 7.5 8 9.5 10 1 1 0 2 35 2 32 10 16.7 17 0 21 20 5 10 11 12.5 12.5 1 1 0 2 40 1 45 12.5 20 0 21 25 25 7.5 12.5 13 16 15 0 1 2 1 1 2 50 1 45 15 25 26 31 30 10 15 16 18 20 0 0 1 2 1 1 2 63 1 60 20 30 31 38 35 16 22 23 27 25 0 0 1 2 1 1 2 80 1 90 25 45 47 56 55 20 35 36 44 40 0 0 1 2 0 1 1 1 2 125 1 110 35 55 57 69 65 30 45 47 56 50 0 0 1 2 0 1 1 1 2 160 1 140 45 70 73 88 85 35 60 62 75 70 0 0 1 2 0 1 1 1 2 Cat. no. (1) Ith For series CSCN12 ... CSCN25 For series CSCN30 For series CSCN45 ... CSCN70 Pack Ref. no. see bottom CSCN12A320 © CSCN12A311 © CSCN12A302 © CSCN16A320 © CSCN16A311 © CSCN16A302 © CSCN20A310 © CSCN20A301 © CSCN20A321 © CSCN20A312 © CSCN25A310 © CSCN25A301 © CSCN25A321 © CSCN25A312 © CSCN30A310 © CSCN30A301 © CSCN30A321 © CSCN30A312 © CSCN45A310 © CSCN45A301 © CSCN45A320 © CSCN45A311 © CSCN45A312 © CSCN55A310 © CSCN55A301 © CSCN55A320 © CSCN55A311 © CSCN55A312 © CSCN70A310 © CSCN70A301 © CSCN70A320 © CSCN70A311 © CSCN70A312 © LB1A © LB3A © LB4A © 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5 5 5 Oder codes Spare coils A B C D (1) To complete the reference, replace © by the code corresponding to the voltage and frequency of the control circuit. (see pg. C.80) E F G H I X C.81 Contactors for capacitors switching Series CSCN A B C Technical data Technical characteristics Main circuit (poles) Rated operational voltage (V) Rated insulation voltage according to IEC947 (V) Rated thermal current (A) Max. power utilization 230/240V (kvar) at 55ºC 380/400V (kvar) 660/690V (kvar) Electrical endurance (ops.) Max. ops./hour (ops./hour) CSCN12 CSCN16 CSCN20 CSCN25 CSCN30 CSCN45 CSCN55 CSCN70 690 1000 25 7,5 12.5 15 280.000 350 690 1000 32 10 16,7 20 280.000 350 690 1000 45 12,5 20 25 280.000 350 690 1000 45 15 25 30 250.000 240 690 1000 60 20 30 35 200.000 240 690 1000 90 25 45 55 150.000 150 690 1000 110 35 55 65 120.000 150 690 1000 140 45 70 85 90.000 150 Control circuit Standard voltages Consumption Single frequency Dual frequency 50Hz Dual frequency 60Hz 50Hz 60Hz (V) (V) 24-690 24-600 24-690 24-600 24-690 24-600 24-690 24-600 24-690 24-600 24-690 24-600 24-690 24-600 24-690 24-600 Mar. circuit open Mar. circuit closed Mar. circuit open Mar. circuit closed Mar. circuit open Mar. circuit closed (VA) (VA) (VA) (VA) (VA) (VA) 45 6 54 7 35 5 45 6 54 7 35 5 48 7 58 8 39 6 48 7 58 8 39 6 88 9 125 11.5 110 11 191 15,5 245 20 215 15 191 15,5 245 20 215 15 198 17 250 23 220 19 CSCN45 CSCN55 CSCN70 Instantaneous auxiliary contact blocks Rated insulation voltage Ui Rated thermal current Ith (V) (A) 1000 10 Ambient conditions Storage temperature (ºC) Operating temperature (ºC) Altitude up to 3000m Mounting positions -50 ... +80 -25 to +55 (without derating) Nominal values Vertical mounting +/- 30º Terminal capacity and tightening torque D E F G H I X C.82 CSCN12 CSCN16 CSCN20 CSCN25 CSCN30 Solid, stranded and finely stranded 1 x 0.5 ... 2,5 1 x 0.5 .. 2,5 – without end sleeve (mm2) 1 x 2.5 ... 6 1 x 2.5 ... 10 – Finely stranded with or 1 x 1 ... 2,5 1 x 1 ... 2,5 – without end sleeve (mm2) 1 x 2.5 ... 6 1 x 2.5 ... 10 – AWG wires 1 x 20 ... 12 1 x 20 ... 8 – Tightening torque (Nm) 1.6 2.2 – (Lb x in.) 15 20 – Solid, stranded and finely stranded without end sleeve (mm2) – – 0.75 ... 16 Finely stranded with end sleeve (mm2) – – 0.75 ... 16 Finely stranded without end sleeve(mm2) – – 1 ... 16 AWG wires – – 18 ... 6 Tightening torque (Nm) – – 1.8 (Lb x in.) – – 16 Solid (mm2) – – 0.75 ... 16 Stranded (mm2) – – 0.75 ... 16 Finely stranded without end sleeve(mm2) – – 0.75 ... 16 Finely stranded with end sleeve (mm2) – – 1 ... 16 AWG wires – – 18 ... 6 Tightening torque (Nm – – 1.8 (Lb x in.) – – 16 Solid, stranded and finely stranded – – Max. 16 without end sleeve (mm2) – – Finely stranded without end sleeve(mm2) – – Max. 16 Finely stranded with end sleeve (mm2) – – Max. 16 AWG wires – – Max. 6 – – Tightening torque (Nm) – – 1.8 (Lb x in.) – – 16 – – – – – – – – – – – – – – 1 ... 35 1 ... 35 1 ... 35 16 ... 2 4 35 1 ... 16 1 ... 25 1 ... 25 1 ... 25 16 ... 4 4 35 Max. 50 ... 4 Max. 25 ... 16 Max. 35 ... 2,5 Max. 25 ... 16 Max. 35 ... 16 Max. 25 ... 25 Max. 2 ... 12 Max 4 ... 4 4 35 1.5 ... 50 1.5 ... 50 1.5 ... 50 16 ... 2 5.6 50 4 ... 35 4 ... 35 4 ... 35 4 ... 35 10 ... 1 5.6 50 Max. 50 ... 35 Max. 35 Max. 35 Max. 1 5.6 50 Series CSCN Standard contactors Series “CL“ and “CK“ contactors, to switch three phase capacitor banks Electrical endurance: >100,000 operations θ ≤ 55ºC Contactor Type (1) Ith A 25 25 32 45 45 60 60 90 110 110 140 140 250 250 315 315 450 600 700 1000 1250 400V 415V 500V 230V 240V kvar kvar kvar kvar 3 4.5 6.5 7.5 9 12.5 16.5 22 25 30 40 50 60 70 80 95 105 135 190 250 315 5 9.5 11 12.5 15 21 25 40 45 50 65 80 110 125 150 165 190 260 325 400 525 5.5 10.5 12 14 16.5 23 27 43 48 54 70 85 118 135 160 177 205 280 350 430 565 6.5 12.5 14.5 16 20 27.5 32 52 58 65 85 105 145 162 195 215 250 340 425 520 685 690V 660V kvar 5.7 11 12.5 15 17.5 24 30 50 65 70 95 120 150 170 200 230 288 370 450 600 650 (1) To complete contactor reference, see C.10 for CL and C.18 for CK 220V 400V 415V 500V 230V 240V kvar kvar kvar kvar 2.4 3.6 5.2 6.5 7.2 10 13 17 19 22 35 43 48 56 64 85 95 120 152 200 252 4 6 8.5 10 12 17 20 30 35 40 58 70 88 100 120 148 175 235 260 320 420 4.5 6.5 9 11 13 18 22 33 37 43 62 75 94 107 130 160 188 252 280 344 452 5.2 10 11.5 13 16 22 25 41 46 52 75 90 116 130 156 192 230 375 340 416 548 690V 660V kvar 4.5 7 10 12 14 19.5 22 35 40 50 85 105 120 136 160 205 265 330 360 480 520 Fuse gl - gG I max. (peak) A A 10 16 25 25 35 40 50 80 125 125 160 160 250 250 315 315 450 630 800 1000 1250 1000 1000 1000 1000 2500 2500 2500 3500 3500 3500 3500 3500 5000 5000 5000 5000 5500 10000 10000 12000 15000 Technical data CL00A CL01A CL02A CL25A CL03A CL04A CL45A CL06A CL07A CL08A CL09A CL10A CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B θ ≤ 70ºC 220V A B C D E F G H I X C.83 Dimensional drawings Contactors for capacitors switching 90 5.5 90 5.5 56 5.5 5.5 5.5 56 90 CSCN70... 56 56 56 55 55 55 66 133 139.5 7.5 133 133 133 139.5 139.5 139.5 7.5 7.5 7.5 7.5 144 150.5 66 144 6666 66 66 9 66 9 66 66 66 9 99 168.5 77 162 77 77 7577 9 168.5 162 162 162 168.5 168.5 168.5 75 9 75 75 75 9 99 86 CSC30 CSC30 CSC30 150.5 144 144 144 150.5 150.5 150.5 162 77 CSC30 172 178.5 86 172 86 86 86 178.5 172 172 172 178.5 178.5 178.5 CSC45 CSC55 CSC45 CSC55 CSC45 CSC45 CSC55 CSC55 128.5 90 5.5 56 133 CSC20 CSC25 CSC20 CSC25 CSC20 CSC20 CSC25 CSC25 CSC70 128.5 128.5 128.5 128.5 5.5 60 56 56 56 60 60 60 H 73 73 73 50 50 50 50 50 60 50 50 50 60 60 60 40 50 60 55 45 60 5.5 5.5 5.5 56 G C.84 4.5 90 90 90 CSCN45..., CSCN55... 56 5556 56 56 4.5 4.5 4.5 40 7.5 7.5 7.5 139.5 4.54.5 4.5 4.5 45 40 40 40 45 45 45 E X 4.5 7.5 137.5 131 131 131 137.5 137.5 7.5 137.5 118.5 D 73 73 45 45 45 56 79 79 79 79 79 C 73 7373 73 45 50 35 4.5 CSCN30... 131 45 35 35 35 131 137.5 35 4.5 4.5 4.5 CSCN20..., CSCN25... B I 50 50 5050 4.5 A F 4.5 82.5 7.5 7.5 7.5 82.5 82.5 82.5 82.5 45 45 45 35 35 35 CSC12 CSC16 CSC12 CSC16 CSC12 CSC12 CSC16 CSC16 85.5 7.5 85.5 85.5 85.5 85.5 45 90.5 35 90.5 90.5 90.5 90.5 7.5 73 45 50 35 118.5 118.5 118.5 118.5 CSCN12..., CSCN16... 90 90 90 Contactors for capacitors switching Series CSCN CSC70 CSC70 CSC70 Series CSCN Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A B C D E F G H I X C.85 Series 390.R Clapper contactors 40A to 800A (AC-3) / 45A to 1200A (AC-1) AC and DC control using a bridge rectifier, designed to meet the most recent stringent requirements in terms of reliability, service life and performance. Main characteristics Clapper contactors • Sliding contact holder, set on self-centering and self-lubricating bronze bushings • Minitubes made of high-strength, high electrical resistance material • Individual auxiliary contacts Construction Variable composition contactors (the number of main poles and auxiliary contacts may vary), preferably secured on mounts Control circuit IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 Solid iron magnetic circuit with coil powered by direct or rectified current, particularly for heavy-duty applications (e.g., cranes, roll mills, reversing winches, etc.). The coils are sized for intermittent operation. For continuous operation, insert an economy resistor in series with the coil using the respective auxiliary contact. Standard voltages Main contacts Alternating current (V) Dual-frequency coils The sintered main contacts are classified as Type 4/2 for intermittent operation and Type 5/2 for continuous operation. The 4/2 sintered contact may be used only for heavy-duty operation when the number of switching operations per hour is above 60 and the operating intermittence is equal or less than 60% (cranes, roll mills, etc.). If used for continuous operation, the contact will overheat. The 5/2 sintered contact may be used only for normal duty when the number of switching operations per hour is equal to or less than 60% and the operating intermittence is above 60%. Standards A B C AP CP EP GP 50/60Hz 24 48 110220 D Direct current (V) E A B C D E F G H M R Voltage20 24 40 48 97 110197220230125 Auxiliary contacts F Individual NO or NC single-breake contacts Possibility to advance or delay contact making or breaking G Special versions The following items may be supplied upon request: • Contactors with coils having an operating limit that exceeds the limits required by the standards • Contactors with an operating voltage up to 3000V (rotary disconnect switches, induction furnaces, etc.) • Vertical mechanical interlocks ideal for interlocking 3 contactors. H I Spare parts and additional components X Spare parts and additional components for the contactors are listed on page C.91. Order codes Coils Spare parts Technical data Dimensional drawings C.86 ! ! ! ! ! pg. C.87 pg. C.90 pg. C.91 pg. C.94 pg. C.96 Series 390.R Control voltage and normal combinations Normal rated voltages, shaft spacing and combinations (main and auxiliary poles) have been defined for each switchgear unit, thereby allowing the contactor to be rapidly selected. AC rated voltages: 24V - 48V - 110V - 220/230V DC rated voltages: 24V - 48V - 110V - 220/230V Spacing between standarised shafts and combinations: See pages C.96 to C.98 Standard center-to-center spacing (mm): 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 The poles can be constructed as follows, depending on the operating conditions: Z design (NO) - For load breaking, with high breaking capacity - For AC or DC use - Equipped with magnetic arc-quenching coil. In the case of AC, the poles are normally sup plied with an appropriate arc-quenching coil for the maximum rated current of the pole. - Arc-quenching coils for medium rated currents with respect to the expected peak current are available for DC use upon request, for more effective pole performance (see table on page C.90). RN design (NC) - Based on the use of break poles, which are open when the coil is energized and closed when the coil is de-energised. - For AC or DC use in special circuits where high interrupting capacities are not required. - This design is intended to be used with contactors R1, R2, R3, R4, R5, R7. Order codes Main poles A B C Poles Z RN R1 R2 R3 R4 R5 R6 R7 R8 R9 D E Order codes - Clapper contactors Peak operating current Resistive Motors loads <440V, 3~ 50/60Hz AC1 AC3 A A 45 40 AC-3 admissible rated powers Electric endur. 220V 230V 380V 400V 415V 440V 500V kW HP kW HP kW HP kW HP Cat. AC3 Switching operations 11,5 20 20 20 1 x 106 AC or DC Pack. See the following pages C.84 and C.85 on how to complete the catalogue number G R1 . . . 1 90 90 26 45 45 45 1 x 106 R2 . . . 1 125 120 36.5 62 62 73.5 1 x 106 R3 . . . 1 250 200 72.5 100 100 120 1 x 106 R4 . . . 1 320 320 93 160 160 165 1.2 x 106 R5 . . . 1 450 450 130 225 225 300 1.5 x 106 R6 . . . 1 630 630 184 315 315 400 1 x 106 R7 . . . 1 800 800 232 400 400 500 0.9 x 106 R8 . . . 1 - - - - - - R9 . . . 1 1500 F H I X C.87 Series 390.R Clapper contactors Catalogue number structure A 2 Product line Size Size 1 2 B 1 Max. 500V AC 250V DC 1 Ith 45 90 125 250 320 450 630 800 1200 Coil voltage 3 4 C AC 3 E F G 1 2 3 4 5 6 7 8 9 Types R1 ... R7 24V 48V 110V 220V Auxiliary contacts 7 I X C.88 5 6 7 8 9 Resistor No. NO aux. contacts No. NC aux. contacts No. “Z” poles “Z” poles 6 1 2 3 4 5 6 1 2 3 4 P P P P - E G E F G H M P P - If required (5/2 contacts) If not required 11 1 2 5 R - “RN” poles 0 1 2 3 4 “Z” poles Type R1 R2 R3 R4 R5 R6 R7 R8 R9 Standard Upon request Arcquenching coil «RN» A B C poles 13 Z - Standard Upon request Arcquenching coil “Z” A B C poles 45A 90A 125A 200A 320A 450A 630A 800A 1200A 14A 25A 45A 75A 50A 130A 150A 270A 320A 320A 400A - V - Note: The “RN” poles are not available for the R6, R8 and R9 types. 9 Type of pole Z No “Z” poles 9 1 2 3 4 12 Type of pole RN No “RN” poles 8 “Z” poles 0 1 2 3 4 1 2 3 4 Note: The “RN” poles are not available for the R6, R8 and R9 types. 12 8 11 “RN” poles 0 1 2 3 4 “RN” poles 4 A C E G A B C D E F G H M R “RN” poles” (NC) 7 NC “Z” poles” (N) Economy resistor 5 NO 1 2 3 4 5 6 6 10 H 4 Coil voltage DC 20V 24V 40V 48V 97V 110V 197V 220V 230V 125V Types R8 and R9 110V 220V 97V 110V 197V 220V 230V 125V D R R R R R R R R R 2 3 Type R1 R2 R3 R4 R5 R6 R7 R8 R9 45A 90A 125A 200A 320A 630A - 14A 25A 45A 75A 50A 130A 150A 320A - Note: The “RN” poles are not available for the R6, R8 and R9 types. Type of contacts 14 Type 4/2 5/2 Intermittent op. Continuous op. 14 4 5 Series 390.R 10 11 12 13 14 15 16 17 18 Arc-quenching coil “Z” poles No. “RN” poles “RN” poles Arc-quenching coil Type of contacts Stationary support Space Shaft Isolation “RN” poles R3 15 Length (mm) 150 200 250 300 350 400 450 500 600 700 800 900 1000 Schaft (Hstat. sup.) R8 17 A B C D E F G H I L M N O C D E F G H I L M N O E F G H I L M N O F G H I L M N O Length (mm) 150 200 250 300 350 400 450 500 600 700 800 900 1000 Isolation Contactor type R1 R2 R3 A B C D E F G H I L M N O R4 R5 C D E F G H I L M N O R6 R7 R8 E F G H I L M N O R9 18 18 For more isolation Not required F G H I L M N O M - Order codes Contactor type StatioR1 R4 R6 R9 nary R5 R7 support R2 A B C Space 16 No space Station. sup. =Shaft Left Space Right 16 S - Stationary support Shaft Stationary support = Shaft Stationary support Stationary support Shaft Space to left Shaft Space to right D E F G H I X C.89 Series 390.R Standardised DC or rectified coils The DC coils are suitable for intermittent operation; for continuous operation, an economy resistor must be used. The coils for rectified rated voltages 20-40-97-197V obtained from AC power supplies. (before the rectifier). 24-48-110-220V are available upon request. For the contactor of “RN” break poles, contact GE. Contactor Voltage VDC Coil Clapper contactors Cat. no. A R1 R2 20 24 40 48 97 110 197 220 230 125 R3 20 24 40 48 97 110 197 220 230 125 R4 20 24 40 48 97 110 197 220 230 125 R5 20 24 40 48 97 110 197 220 230 125 R6 20 24 40 48 97 110 197 220 230 125 R7 20 24 40 48 97 110 197 220 230 125 R8 97 110 197 220 R9 97 110 197 220 B C D E F G H I X Economy resistor for continuous operation ± 5% Ref. no. Ω W 39012Y20D 39012Y24D 39012Y40D 39012Y48D 39012Y97D 39012Y110D 39012Y197D 39012Y220D 39012Y230D 39012Y125D 244107 202327 244106 244734 202328 202323 202325 202326 211706 202324 4 3903Y20D 3903Y24D 3903Y40D 3903Y48D 3903Y97D 3903Y110D 3903Y197D 3903Y220D 3903Y230D 3903Y125D 215278 244735 244088 212705 213691 202437 214442 202438 211107 216100 4 3904Y20D 3904Y24D 3904Y40D 3904Y48D 3904Y97D 3904Y110D 3904Y197D 3904Y220D 3904Y230D 3904Y125D 244084 202483 244083 213814 213601 202479 202481 202482 211708 202480 6 3905Y20D 3905Y24D 3905Y40D 3905Y48D 3905Y97D 3905Y110D 3905Y197D 3905Y220D 3905Y230D 3905Y125D 244073 244072 244071 244736 202513 202512 244074 212706 211709 242260 10 3906Y20D 3906Y24D 3906Y40D 3906Y48D 3906Y97D 3906Y110D 3906Y197D 3906Y220D 3906Y230D 3906Y125D 244065 244064 244063 212707 202533 202532 244066 213612 211770 211711 10 3907Y20D 3907Y24D 3907Y40D 3907Y48D 3907Y97D 3907Y110D 3907Y197D 3907Y220D 3907Y230D 3907Y125D 244058 244057 244056 244737 244738 202547 244059 202548 211712 211713 16 3908Y97D 3908Y110D 3908Y197D 3908Y220D 212959 202565 214066 202566 16 3909Y97D 3909Y110D 3909Y197D 3909Y220D 214146 202572 204181 244739 140 8.2 18 33 68 220 330 680 1200 1200 330 8.2 18 39 47 270 330 820 1200 1200 330 8.2 18 33 33 180 180 680 680 680 180 6.8 10 27 27 120 180 470 680 680 180 6.8 8.2 27 27 100 180 470 680 680 180 5.6 5.6 15 18 82 100 330 390 1200 330 82 120 390 470 100 150 390 560 Cat. no. Ref. no. V Cat. no. Ref. no. 50/60Hz RSS13/64TA8,2 204177 24 MSK-B250/220-1,5209997 RSS13/64TA18 211727 RSS13/64TA33 211728 48 MSK-B250/220-1,5209997 RSS13/64TA6,8 214869 RSS13/64TA220 212702 110 MSK-B250/220-1,5209997 RSS13/64TA330 211745 RSS13/64TA680 214580 220 MSK-B250/220-1,5209997 RSS13/64TA1200 213034 RSS13/64TA1200 213034 RSS13/64TA300 211714 RSS13/64TA8,2 204177 24 MSK-B250/220-1,5209997 RSS13/64TA18 211727 RSS13/64TA39 211730 48 MSK-B250/220-1,5209997 RSS13/64TA47 211731 RSS13/64TA270 214399 110 MSK-B250/220-1,5209997 RSS13/64TA330 211745 RSS13/64TA820 214400 220 MSK-B250/220-1,5209997 RSS13/64TA1200 213034 RSS13/64TA1200 213034 RSS13/64TA300 211714 RSS13/64TA8,2 204177 24 MSK-B250/220-1,5209997 RSS13/64TA18 211727 RSS13/64TA33 211728 48 MSK-B250/220-1,5209997 RSS13/64TA33 211728 RSS13/64TA180 211744 110 MSK-B250/220-1,5209997 RSS13/64TA180 211744 RSS13/64TA680 214580 220 MSK-B250/220-1,5209997 RSS13/64TA680 214580 RSS13/64TA680 214580 RSS13/64TA180 211744 RSS13/64TA6,8 214869 24 SKB-B80/70-4 211716 RSS13/64TA10 211742 RSS13/64TA27 244192 48 MSK-B250/220-1,5209997 RSS13/64TA27 244192 RSS13/64TA120 243281 110 MSK-B250/220-1,5209997 RSS13/64TA180 211744 RSS13/64TA470 244191 220 MSK-B250/220-1,5209997 RSS13/64TA680 214580 RSS13/64TA680 214580 RSS13/64TA180 211744 SKB-B80/70-4 211716 RSS13/64TA6,8 214869 24 RSS13/64TA8,2 204177 RSS13/64TA27 244192 48 MSK-B250/220-1,5209997 RSS13/64TA27 244192 RSS13/64TA100 211744 110 MSK-B250/220-1,5209997 RSS13/64TA180 211744 RSS13/64TA470 244191 220 MSK-B250/220-1,5209997 RSS13/64TA680 214580 RSS13/64TA680 214580 RSS13/64TA180 211744 SKB-B80/70-4 211716 RSS13/64TA5,6 211735 24 RSS13/64TA5,6 211735 SKB-B80/70-4 211716 RSS13/64TA15 211737 48 RSS13/64TA18 211727 RSS13/64TA82 204177 110 MSK-B250/220-1,5209997 RSS13/64TA100 211743 RSS13/64TA330 211745 220 MSK-B250/220-1,5209997 RSS13/64TA390 211746 RSS13/64TA1200 213034 RSS13/64TA330 211745 RSS20/165TA82 214081 110 SKB-B250/220-4 212165 RSS20/165TA120 213664 RSS20/165TA390 211748 220 MSK-B250/220-1,5209997 RSS20/165TA470 211739 RSS20/165TA100 213663 110 SKB-B30/08 211720 RSS20/165TA150 215004 RSS20/165TA390 211748 220 SKB-B500/445-4 214501 RSS20/165TA560 244987 - (1) To insert the resistors, use NC auxiliary contacts in series. (2) Two 20x165 resistors connected in parallel, each with a resistive value listed in the table. C.90 Single-phase bridge rectifier for AC power Series 390.R Spare parts Contactor Description Cat. no. Ref. no. Pack (units) R1 “Z” stationary part with 14A arc-quenching coil and spark suppressor 390/3921PFZCS14 202273 1 “Z” stationary part with 25A arc-quenching coil and spark suppressor 390/3921PFZCS25 244172 1 “Z” stationary part with 45A arc-quenching coil and spark suppressor 390/3921PFZCS45 202274 1 “RN” stationary part with spark suppressor 390/3921PFRN 244173 1 “Z” moving part (with pressure spring and strap) 390/3921PMZI 202276 1 1 1 1 1 R2 “Z” stationary part with 45A arc-quenching coil and spark suppressor 390/3922PFZCS45 244744 “Z” stationary part with 90A arc-quenching coil and spark suppressor 390/3922PFZCS90 202278 “RN” stationary part with spark suppressor 390/3922PFRN 212709 “Z” moving part (with pressure spring and strap) 390/3922PMZI 202279 “RN” moving part (with pressure spring and strap) 390/3922PMRN 213014 Stationary and moving main contact, type 4/2 (intermittent operation)390/3921/2FOM4/2214120 Stationary and moving main contact, type 5/2 (continuous operation) 390/3922FOM5/2 214121 Spark suppressor for “Z” and “RN” poles 390/3922PZ 202280 1 1 1 1 1 1 1 1 R3 “Z” stationary part with 75A arc-quenching coil and spark suppressor 390/3923PFZCS75 “Z” stationary part with 125A arc-quenching coil and spark suppressor 390/3923PFZCS125 “RN” stationary part with spark suppressor 390/3923PFRN “Z” moving part (with pressure spring and strap) 390/3923PMZI “RN” moving part (with pressure spring and strap) 390/3923PMRN Stationary and moving main contact, type 4/2 (intermittent operation) 390/3923/2FOM4/2 Stationary and moving main contact, type 5/2 (continuous operation) 390/3923FOM5/2 Spark suppressor for “Z” and “RN” poles 390/3923PZ 244745 202281 213986 202283 202282 214122 214123 202284 1 1 1 1 1 1 1 1 “ Z” stationary part with 125A arc-quenching coil and spark suppressor 390/3924PFZCS125 “Z” stationary part with 200A arc-quenching coil and spark suppressor 390/3924PFZCS200 “RN” stationary part with spark suppressor 390/3924PFRN “Z” moving part (with pressure spring and strap) 390/3924PMZI “RN” moving part (with pressure spring and strap) 390/3924PMRN Stationary main contact, type 4/2 (intermittent operation) 390/3924F4 Moving main contact, type 4/2 (intermittent operation) 390/3924M4/2 Stationary main contact, 5/2 type (continuous operation) 390/3924F5/2 Moving main contact, type 5/2 (continuous operation) 390/3924M5/2 Spark suppressor for “Z” and “RN” poles 390/3924PZ 202288 202289 202287 202291 202290 214124 214126 204178 214127 202292 1 1 1 1 1 1 1 1 1 1 “ Z” stationary part with 125A arc-quenching coil and spark suppressor 390/3925PFZCS150 213573 “Z” stationary part with 320A arc-quenching coil and spark suppressor 390/3925PFZCS320 202295 “RN” stationary part with spark suppressor 390/3925PFRN 244746 “Z” moving part (with pressure spring and strap) 390/3925PMZI 202298 “RN” moving part (with pressure spring and strap) 390/3925PMRN 202297 Stationary main contact, type 4/2 (intermittent operation) 390/3925F4/2 214128 Moving main contact, type 4/2 (intermittent operation) 390/3925M4/2 214130 Stationary main contact, 5/2 type (continuous operation) 390/3925F5/2 214129 Moving main contact, type 5/2 (continuous operation) 390/3925M5/2 214131 Spark suppressor for “Z” and “RN” poles 390/3925PZ 202299 1 1 1 1 1 1 1 1 1 1 “ Z” stationary part with 270A arc-quenching coil and spark suppressor 390/3926PFZCS270 “Z” stationary part with 450A arc-quenching coil and spark suppressor 390/3926PFZCS450 “Z” moving part (with pressure spring and strap) 390/3926PMZI Stationary main contact, type 4/2 (intermittent operation) 390/3926F4/2 Moving main contact, type 4/2 (intermittent operation) 390/3926M4/2 Stationary main contact, 5/2 type (continuous operation) 390/3926F5/2 Moving main contact, type 5/2 (continuous operation) 390/3926M5/2 Spark suppressor for “Z” and “RN” poles 390/3926PZ 1 1 1 1 1 1 1 1 R4 R5 R5 202303 213574 202304 214133 214135 214134 214136 202654 Order codes “RN” moving part (with pressure spring and strap) 390/3921PMRN 202275 Stationary and moving main contact, type 4/2 (intermittent operation) 390/3921/2FOM4/2 214120 Stationary and moving main contact, type 5/2 (continuous operation) 390/3922FOM5/2 214121 Spark suppressor for “Z” and “RN” poles 390/3921PZ 202277 A B C D E F G H I X C.91 Series 390.R Spare parts (continued) Clapper contactors Contactor Description Cat. no. Ref. no. Pack (units) R7 “Z” stationary part with 320A arc-quenching coil and spark suppressor390/3927PFZCS320 202307 “Z” stationary part with 630A arc-quenching coil and spark suppressor 390/3927PFZCS630 202308 “RN” stationary part with spark suppressor 390/3927PFRN 202306 “Z” moving part (with pressure spring and strap) 390/392PMZI 202310 “RN” moving part (with pressure spring and strap) 390/3927PMRN 202309 Stationary main contact, type 4/2 (intermittent operation) 390/3927F4/2 214137 Moving main contact, type 4/2 (intermittent operation) 390/3927M4/2 214139 Stationary main contact, 5/2 type (continuous operation) 390/3927F5/2 214138 Moving main contact, type 5/2 (continuous operation) 390/3927M5/2 214140 Spark suppressor for “Z” and “RN” poles 390/3927PZ 202311 1 1 1 1 1 1 1 1 1 1 R8 “Z” stationary part with 400A arc-quenching coil and spark suppressor 3908PFZCS400 “Z” stationary part with 800A arc-quenching coil and spark suppressor 3908PFZCS800 “Z” moving part (with pressure spring and strap) 3908PMZ Stationary main contact, type 4/2 (intermittent operation) 3908F4/2 Moving main contact, type 4/2 (intermittent operation) 3908/9M4/2 Stationary main contact, 5/2 type (continuous operation) 3908F5/2 Moving main contact, type 5/2 (continuous operation) 3908/9M5/2 Spark suppressor for “Z” and “RN” poles 3908PZ 202555 202562 202563 214144 214141 214145 214142 202564 1 1 1 1 1 1 1 1 “Z” stationary part with 1200A arc-quenching coil and spark suppr. “Z” moving part (with pressure spring and strap) Stationary main contact, type 4/2 (intermittent operation) Moving main contact, type 4/2 (intermittent operation) Stationary main contact, 5/2 type (continuous operation) Moving main contact, type 5/2 (continuous operation) 244983 212962 204179 214141 204180 214142 1 1 1 1 1 1 R8 A B C D E F G H I X C.92 3909PFZCS120 3909PMZ 3909F4/2 3908/9M4/2 3909F5/2 3908/9M5/2 Series 390.R Operating categories AC-1 AC-3 DC1 L/R H 1ms DC3 L/R H 2.5ms DC5 L/R H 15ms R2... R3... R4... R5... (A) (A) (A) (kW) (kW) (kW) (kW) (mm2) (%) (%) 45 45 30 17 29 32 39 10 100 50 90 90 70 30 55 57 69 35 100 50 125 125 100 45 75 85 102 50 100 50 250 250 200 90 155 180 200 120 100 50 320 320 280 114 196 227 250 185 100 30 (A) (kW) (kW) (kW) (kW) (%) (%) 40 11.5 20 20 20 100 50 90 26 45 45 45 100 50 110 36.5 62 68 72,5 100 50 200 72.5 100 100 120 100 50 320 93 160 160 165 100 50 450 130 225 225 280 100 50 630 184 315 315 400 100 30 800 232 400 400 500 100 30 - (A) (kW) (HP) (kW) (HP) (kW) (HP) (A) (kW) 18.5 4 5.3 9 11.9 11 14.6 40 18.5 44 11 14.6 22 29.2 25 33.2 90 38 55 15 19.9 28 37.2 33 43.9 110 55 110 33 43.9 55 73.1 75 99.7 185 90 125 37 49.2 63 83.8 90 119.7 280 150 150 45 59.8 80 106 100 133 420 220 165 50 66.5 90 119.7 110 146 590 300 250 80 106 132 175.5 225 299 700 375 - Series poles R1... R2... R3... R4... R5... R6... R7... R8... R9... 1 2 3 4 1 2 3 4 1 2 3 4 40 60 60 60 20 30 40 40 20 20 85 90 90 90 75 90 90 90 75 90 90 115 125 125 125 110 115 125 125 100 125 125 180 200 200 200 160 200 250 250 200 250 250 300 320 320 320 275 300 320 320 275 320 320 400 450 450 450 350 370 400 450 350 400 450 600 630 630 630 500 560 630 630 500 600 630 700 750 800 800 600 650 750 800 600 700 800 900 1000 1250 1250 800 900 1000 1250 800 900 1000 1 2 3 4 1 2 3 4 1 2 3 4 30 40 45 45 15 20 25 10 13 75 80 90 100 65 90 90 55 70 100 110 110 120 90 110 110 75 100 170 200 200 220 155 200 200 120 160 280 320 320 340 245 320 320 200 260 380 450 450 480 340 450 450 300 400 550 630 630 460 630 630 400 550 650 800 800 550 800 800 500 660 - 1 2 3 4 1 2 3 4 1 2 3 4 27 35 40 40 13 18 22 9 11 50 70 90 90 55 80 80 50 60 70 90 100 110 80 100 100 67 90 90 150 200 200 140 180 180 100 130 240 280 320 320 220 290 290 180 224 320 380 420 450 300 400 400 270 360 400 450 500 500 410 560 560 360 480 500 550 600 650 490 700 700 450 600 - Peak operating current at ambient temp. of: (for all rated voltages) Max. operating power Resistor III 40ºC 55ºC 70ºC 230/220V 400/380V 440/415V 500V Conductor Operation in % of peak 120 ops./h operating current 300 ops./h Peak operating current Ue = 400V Max. operating power 230/220V 400/380V 440/415V 500V Use in % of peak 120 ops./h operating current 300 ops./h Peak operating current Ue = 500V Operating power 230/220V (200,000 switching 400/380V 500V Peak operating current H 400V Max. operating power 400/380V Ue 125V 220V 440V 125V 220V 440V 125V 220V 440V R6... R7... R8... R9... 450 630 800 1200 450 600 750 1200 360 500 700 950 170 195 240 450 310 330 410 750 340 330 500 900 390 420 550 1030 2 x (30x5) 2 x (40x5) 2 x (60x5) 4 x (50x5) 100 100 100 50 30 20 10 10 Technical data AC-4 R1... A B C D E F G H I X C.93 Series 390.R Technical data Standards Maintenance IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 C =Opening of the moving core C1 =Opening of moving core when the contacts start to touch. The data listed in the table refers to contactors in a normal three-pole design and may vary in the case of special designs. Clapper contactors Ambient conditions A B Storage temperature Operating temperature -40°C to +60°C Altitude up to 2500m 3000 to 4000m 4000 to 5000m -55°C to +80°C Rated values 90%Ie 80%Ue 80%Ie 75%Ue Climatic withstand capacity (IEC 68-2) Continuous testing 40/125/56 Cold (72h) Temperature Dry heat (96h) Temperature Relative humidity Moist heat (56 days) Temperature Relative humidity Cyclic testing First half-cycle (12h) Low temperature Relative humidity Second half-cycle (12h) Low temperature Relative humidity No. consecutive cycles DC power supply -40°C +125°C < 50% +40°C 95% +25°C 93% +55°C 95% 6 No variation in on and off voltage. No variation in rated power F H I X C.94 Pressure of closed contact in kg (+10% / -30%) 18 18 20 22 24 28 28 34 34 5 5 6 6 7 8 8 10 10 0.750 0.750 0.750 1.300 2.000 3.500 5.500 8.000 15.000 The replacement (due to wear) of the main contacts requires an adjustment to ensure proper distance between the moving and the stationary contacts. The respective adjustment screws should be turned until the main contacts start to touch simultaneously when the gap indicated by A1 or C1 exists between the stationary and the moving magnetic circuit. Make sure that all contactor poles have the same stroke by manually closing the magnetic circuit; if the poles are properly adjusted, they should come into contact at the same time. If contact wear is abnormal, please contact the manufacturer since the apparatus has been improperly chosen for the application conditions. To replace the contacts, loosen the screw securing the contacts to the respective contact holder, making sure that the screws are well-tightened when installing the new contacts. GE Power Controls warrants proper operation of the contactors only if the contacts are replaced with OEM contacts. D G C1 (mm) ±1 Replacement of main contact Mounting positions C E C (mm) ±1 Capacity of terminals and torque Single-core conductor (mm2) Multi-strand conductor (mm2) with terminal sheath Multi-strand conductor (mm2) without terminal sheath Multi-strand (mm2) Single- and multi-strand AWG (mm2) Torque (Nm) (Lb x in) Multi-strand with terminal (mm2) Clappers Torque (Nm) (Lb x in) R1... R2... R3... 2.5...25 2.5...25 2.5...50 2.5...50 2.5...25 2.5...50 4...25 16...4 4 35 4...50 16...2 5,6 50 R4... R5... R6... R7... R8... 1 x 120 2 x 95 7 60 1 x 185 2 x 150 23 200 - - - 2 x (30x5) 31 275 2 x (40x5) 31 275 2 x (60x5) 31 275 R9... Series 390.R Power circuit R1... R2... R3... R4... R5... R6... R7... R8... R9... (A) (A) (V) 45 40 500 90 90 500 125 110 500 250 200 500 320 320 500 450 450 500 630 630 500 800 800 500 1500 500 Rated isolation voltage Ui (V) Maximum continuous current AC-1 (A) Frequency limits (Hz) (Hz) Making capacity (RMS) (IEC947) (A) Breaking capacity (RMS) (IEC 947) Ue ≤ 400V (A) Ue = 500V (A) Short-time current 1 s. (A) 5 s. (A) 10 s. (A) 30 s. (A) 1 min. (A) 3 min. (A) Recovery time (min.) Fused short-circuit protection aM (A) gL-gG (A) Impedance per pole (mΩ) Power dissipated per pole AC-1 (W) AC-3 (W) Isolation resistance Pole-to-pole (mΩ) Pole-to-ground (mΩ) Input-to-output (mΩ) 1000 45 1000 90 1000 125 1000 250 1000 320 1000 450 1000 630 1000 800 1000 1200 540 450 1200 800 500 250 180 100 10 50 80 1 2.1 1.6 1200 960 650 1500 900 650 300 200 150 10 125 160 1 8.1 8.1 1250 1250 1050 2000 1500 1200 750 450 250 10 160 200 0.5 7.8 6 2400 1900 1900 2500 2200 1600 1100 800 500 10 250 315 0.4 25 16 3800 3050 3050 3000 2800 2500 2000 1500 600 10 400 425 0.2 20 20 5400 4350 4350 4250 4000 3900 3700 2500 900 10 630 630 0.3 60 60 7500 6000 6000 5000 4800 4600 4400 3000 1500 10 800 800 0.2 79 79 9600 7700 7700 6000 5700 5500 5200 4000 2300 10 1000 1000 0.25 160 160 4000 4000 4000 10000 9000 8800 8500 5000 3000 10 0.10 144 - >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 R2... R3... R4... R5... R6... R7... R8... R9... 1000 24...220 1000 24...220 1000 24...220 1000 24...220 1000 24...220 1000 24...220 1000 24...220 1000 24...220 Thermal rated current lth at u H 55ºC Rated operating current Ie AC-3 Rated operating voltage Ue (1) 3-pole contactors Control circuit Alternating current Technical data >10 >10 >10 (1) For rated voltages above 500V, contact the manufacturer. A B R1... 1000 Rated isolation voltage Ui (V) Standardized voltages Us at 50/60 Hz (V) 24...220 Single-frequency coil voltage limits Operation xUs 0.85...1.1 Off xUs 0.22...0.55 Consumption of dual-frequency coils (1) 19 Closed magnetic circuit (50 Hz/60 Hz) (VA) 27 Open magnetic circuit (50 Hz/60Hz) (VA) 19 Dissipated thermal power (50 Hz/60 Hz) (W) On and off times. Values at Us 60/70 Making time at de-energisation (NA) (ms) 80/95 Making time at de-energisation (NA) (ms) Mechanical endurance 10 Dual-frequency coils (at 50 Hz) 106 ops. Maximum rate 1200 Dual-frequency coils. No-load ops./h 600 AC-1 with rated power ops./h 250 AC-2 with rated power ops./h 600 AC-3 with rated power ops./h 150 AC-4 with rated power ops./h C 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.85...1.1 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 0.22...0.55 19 27 19 20 38 20 25 41 25 35 57 35 38 60 38 53 90 53 100 440 100 190 1400 190 60/70 80/95 60/70 80/95 110/120 160/170 150/160 200/210 180/200 350/450 200/210 240/250 150/160 150/160 - 10 10 10 10 10 10 8 8 1200 600 250 600 150 600 300 200 300 100 400 120 120 120 60 400 120 120 120 60 400 120 120 120 60 400 120 120 120 60 300 90 90 90 30 300 60 - 1000 24...230 1000 24...230 1000 24...230 1000 24...230 1000 24...230 1000 24...230 1000 24...230 1000 24...230 1000 24...230 0.8...1.1 0.15...0.5 0.8...1.1 0.15...0.5 0.8...1.1 0.15...0.5 0.8...1.1 0.15...0.5 0.8...1.1 0.15...0.5 0.8...1.1 0.15...0.5 0.8...1.1 0.15...0.5 0.8...1.1 0.15...0.5 0.8...1.1 0.15...0.5 14 21 14 21 16 25 22 31 28 45 30 46 42 65 80 400 140 1000 60/70 19/20 10 60/70 19/20 10 60/70 19/20 10 110/120 28/30 10 150/160 40/45 10 180/200 59/60 10 200/210 30/35 10 150/160 25/30 8 8 1200 600 150 1200 600 150 600 300 100 400 120 60 400 120 60 400 120 60 400 120 60 300 90 30 300 - D E F G Direct current Rated isolation voltage Ui (V) Standardized voltages Us (V) Voltage limits Operating xUs Off xUs Power consumption Closed magnetic circuit (W) Open magnetic circuit (W) On and off time Values at Us Making time at energization (NA) (ms) Breaking time at de-energization (NA) (ms) Mechanical endurance 106 ops. Maximum rate No-load ops./h AC1 and AC3 with rated power ops./h AC4 with rated power ops./h (1) With 5/2 contact H I X C.95 Series 390.R Dimensional drawings R1..., R2... Contact combination Clapper contactors “Z” main Max. no. of Max.Max. Center-topole (1) aux. contacts NO NC center spacing 1 1 1 1 150 3 3 3 200 6 6 4 250 9 6 4 300 10 6 4 350 10 6 4 400 2 1 1 1 200 4 4 4 250 7 6 4 300 9 6 4 350 9 6 4 400 3 2 2 2 250 5 5 4 300 7 6 4 350 7 6 4 400 4 2 2 2 300 5 5 4 350 5 5 4 400 (1) A “RN” pole can be used to replace one of the “Z” poles. To use a higher number of “RN” poles, contact the manufacturer. A R3... Contact combination “Z” main Max. no. of Max.Max. Center-topole (1) aux. contacts NO NC center spacing 1 150 3 3 3 200 6 6 4 250 9 6 4 300 10 6 4 350 10 6 4 400 2 200 3 3 3 250 6 6 4 300 8 6 4 350 9 6 4 400 3 250 3 3 3 300 6 6 4 350 7 6 4 400 4 300 3 3 3 350 4 4 4 400 (1) A “RN” pole can be used to replace one of the “Z” poles. To use a higher number of “RN” poles, contact the manufacturer. B C D E F G H I X C.96 R4... Contact combination “Z” main Max. no. of Max.Max. Center-topole (1) aux. contacts NO NC center spacing 1 3 3 3 250 6 6 4 300 9 6 4 350 10 6 4 400 10 6 4 450 2 250 3 3 3 300 6 6 4 350 9 6 4 400 10 6 4 450 3 300 3 3 3 350 6 6 4 400 9 6 4 450 4 3 3 3 400 4 4 3 450 (1) A “RN” pole can be used to replace one of the “Z” poles. To use a higher number of “RN” poles, contact the manufacturer. Series 390.R R5... Contact combination R6... Dimensions “Z” main Max. no. of Max.Max. Center-topole (1) aux. contacts NO NC center spacing 1 2 2 2 250 5 5 4 300 8 6 4 350 10 6 4 400 10 6 4 450 10 6 4 500 2 2 2 2 300 4 4 4 350 7 6 4 400 10 6 4 450 10 6 4 500 3 1 350 4 4 4 400 6 6 4 450 7 6 4 500 4 400 3 3 3 450 3 3 3 500 (1) A “RN” pole can be used to replace one of the “Z” poles. To use a higher number of “RN” poles, contact the manufacturer. A Contact combination “Z” main Max. no. of Max. Max. Center-topole aux. contacts NO NC center spacing 1 2 3 4 5 8 10 10 10 10 1 4 7 9 10 10 2 5 7 7 1 2 2 2 6 6 6 6 6 1 4 6 6 6 6 2 5 6 6 1 2 2 4 4 4 4 4 4 1 4 4 4 4 4 2 4 4 4 1 2 2 350 400 450 500 600 700 350 400 450 500 600 700 450 500 600 700 500 600 700 B C D E F R7... Contact combination “Z” main Max. no. of Max.Max. Center-topole (1) aux. contacts NO NC center spacing 1 4 4 4 350 6 6 4 400 9 6 4 450 10 6 4 500 10 6 4 600 10 6 4 700 2 1 1 1 400 4 4 4 450 7 6 4 500 10 6 4 600 10 6 4 700 3 1 1 1 500 7 6 4 600 8 6 4 700 4 2 2 2 600 5 5 3 700 G H I X (1) A “RN” pole can be used to replace one of the “Z” poles. To use a higher number of “RN” poles, contact the manufacturer. C.97 Series 390.R Dimensional drawings R8... Contact combination Clapper contactors “Z” main Max. no. of Max. Max. Center-topole aux. contacts NO NC center spacing 1 1 1 1 350 4 4 4 400 6 6 4 450 9 6 4 500 10 6 4 600 10 6 4 700 10 6 4 800 2 450 3 3 3 500 8 6 4 600 10 6 4 700 10 6 4 800 3 2 2 2 600 8 6 4 700 8 6 4 800 4 1 1 1 700 4 3 3 800 A R9... Contact combination B C D E F G H I X C.98 “Z” main Max. no. of Max. Max. Center-topole aux. contacts NO NC center spacing 1 2 2 2 400 4 4 4 450 7 6 4 500 10 6 4 600 10 6 4 700 10 6 4 800 10 6 4 900 10 6 4 1000 2 4 4 4 600 9 6 4 700 10 6 4 800 10 6 4 900 10 6 4 1000 3 700 6 6 4 800 8 6 4 900 8 6 4 1000 4 3 3 3 900 4 3 3 1000 48962 GE Consumer & Industrial Power Protection Power Protection (formerly GE Power Controls), a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products imagination at work comes from,GE wholesalers, installers, panel-board builders, contractors, OEMs and utilities worldwide. @ GE imagination at work www.ge.com/ex/powerprotection www.ge.com/eu/powerprotection GE imagination at work GE imagination at work GE imagination at work GE POWER CONTROLS Ltd Houghton Centre Salthouse Road Northampton NN4 7EX United Kingdom Customer Service Tel. 0800 587 1251 Fax 0800 587 1239 E-mail: gepcuk@gepc.ge.com GE CONSUMER & INDUSTRIAL HUNGARY Váci út 77 H-1340 Budapest Hungary Customer Service Tel. +361 447 6046 Fax +361 447 5060 E-mail: mea.export .consind@ge.com Net: www.gepowershop.com GE imagination at work GE CONSUMER & INDUSTRIAL POWER PROTECTION Nieuwevaart 51 B-9000 Gent Belgium Tel. +32/9 265 21 11 Fax +32/9 265 28 00 E-mail: gepcbel@gepc.ge.com GE imagination at work 680804 Ref. C/4601/E/EX 2.5 Ed. 05/09 © Copyright GE Consumer & Industrial 2009