Series LS 30A to 600 Vac SIP Package DC Control Part Number Description LS24D16C-HS1 16A, 240 Vac LS60D22C-HS1 22A, 600 Vac LS24D27C 27A, 240 Vac LS60D30C 30A, 600 Vac Part Number Explanation LS Series 24 D 16 C Control Range3 Switch Type2 Line Voltage Output Current – Amps 1 NOTES 1) Line Voltage (nominal) 24 = 240 Vac; 60 = 600 Vac 2) Switch Type: D = Zero-cross turn-on 3) Control Range: C = 4-14 Vdc MECHANICAL SPECIFICATION 1 Ø1 0.2 (5.08) 0.4 0.5 (12.7) (10.16) .30 (7.83) 1.71 (43.6) (1.5 x 1.5) .16 Hot surface: (4) .69 (17.5) 2 .30 (7.6) .31 (7.83) 3 .02 (.55) .96 (24.5) 4 .06 x .06 .01 (0.3) Hot surface: 1.48 (37.6) .07 ±.006 (1.7 ±0.15) .25 (6.3) FEATURES/BENEFITS • Industry standard package • Designed for external heat-sink attachment • Over-sized thyristor ratings • Direct-copper bonding technology DESCRIPTION These solid-state single inline package (SIP) relays are designed for mounting on printed circuit boards. The Series LS relays facilitate heat sinking by providing an interface surface. The relays are designed with 16A, 25A and 50A thyristors. They can switch loads with high starting currents. The nominal switched currents depend on the size of the heat sink and are limited by the cross section of the tracks of the printed circuit (mainly 25A/30A). The relays use a direct-bonded copper substrate for thermal efficiency, thermal stress performance and long-life expectancy. .07 (1.7) Top view 0.1 (2.54) Hole Ø .06 (1.6) WEIGHT: 0.53 oz. (15g) TOLERANCES: ±.007 (±0.2mm) Figure 1 - LS relays; dimensions in inches (mm) (See Figure 12 for LS with HS1) APPROVALS All models are UL recognized. UL File Number: E128555. TYPICAL APPLICATION L1 L1 MOV on the PCB BLOCK DIAGRAM Load Or SSR APPLICATIONS • Motor control — Pumps, reversing, integration of relays in terminal boxes • Lamp control — Infrared drying, traffic lights, theater lighting MOV on the PCB 3+ Rc Ic 1~ Vc Load SSR N N 4— 2~ Figure 2 — LS relays Figure 3 — LS relays © 2016 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com LS Page 1 LS\092014\Q3 Series LS 30A to 600 Vac SIP Package DC Control CONTROL CHARACTERISTIC INPUT (CONTROL) SPECIFICATION Input Current Range Max 4 14 Vdc 6.5 30 mAdc Must Turn-off Voltage Input Resistance (Typical) Units 1 Vdc 440 Ohms Input Current (mA) Control Range Min OUTPUT (LOAD) SPECIFICATION Min Max Unit 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 Operating Range 0 LS24 12 280 Vrms LS60 24 600 Vrms 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Control Voltage (V) Figure 4 — LS relays THERMAL CHARACTERISTICS Peak Voltage 20 600 Vpeak LS60D22C 1200 Vpeak Load Current Range LS24D16C .005 16* Arms LS60D22C .005 25* Arms LS24D27C .005 30* Arms LS60D30C .005 30* Arms FW150 (~ ~ 3°C/W) FW100 (~ ~ 4°C/W) Full on state 15 Power Dissipation (W) LS24D16C 6°C/W 10 5 Without heat sink 0 0 *Limited by the heat sink 5 10 15 20 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (°C) Load Current (Arms) Figure 5a — LS24D16C relay Maximum Surge Current Rating (Non-Repetitive) 35 (See Figure 6) 160 Apeak LS60D22C 300 Apeak LS24D27C 600 Apeak LS60D30C 1000 Apeak 1.6 V Power Dissipation (W) 30 LS24D16C FW150 (~ ~ 3°C/W) Full on state FW100 (~ ~ 4°C/W) 25 20 6°C/W 15 10 5 On-State Voltage Drop Without heat sink 0 0 5 10 15 20 25 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (°C) Load Current (Arms) Zero-Cross Window (Typical) Off-State Leakage Current (60Hz) ±12 V 1 mA Figure 5b — LS60D22C relays 40 Power Dissipation (W) Full on state FW150 (~ ~ 3°C/W) FW100 (~ ~ 4°C/W) 30 6°C/W 20 10 Without heat sink 0 0 5 10 15 20 25 30 35 Load Current (Arms) 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (°C) Figure 5c — LS24D27C, LS60D30C relays LS Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2016 TELEDYNE RELAYS LS\092014\Q3 Series LS 30A to 600 Vac SIP Package DC Control OUTPUT (LOAD) SPECIFICATION (continued) Min Turn-On Time (60Hz) Turn-Off Time (60Hz) Unit 8.3 ms 8.3 Off-State dv/dt ENVIRONMENTAL SPECIFICATION Max ms 500 V/μs 440 Hz LS24D16C 128 A 2S LS60D22C 450 A 2S LS24D27C 1800 A 2S LS60D30C 5000 A 2S Operating Frequency 10 Min Max Unit Operating Temperature –40 80 °C Storage Temperature –40 120 °C Input-Output Isolation 4000 Vrms Output-Case Isolation 3300 Vrms NOTES: 1. MOV across the output recommended for non-resistive loads — minimum size: 14mm 2. Maximum current based on size of the heat sink and the ambient temperature. 3. For 800Hz applications, contact factory. 4. For additional/custom options, contact factory. I2t for match fusing (<8.3ms) SURGE CURRENTS 700 200 600 Non-Repetitive Non-Repetitive 500 100 50 Apeak Apeak 150 Repetitive with initial Tj = 70°C 0 0.01 0.10 t (s) 1.00 10.0 400 300 200 Repetitive with initial Tj = 70°C Figure 6a — L24D16C relay 100 0 0.01 0.1 1 t (s) 300 Apeak Non-Repetitive 200 Long time overload @ Tj init = 45°C Temps I (A) 60 s 20 100 s 15 100 Repetitive with initial Tj = 70°C 0 0.01 0.10 t (s) 1.00 10.0 Figure 6d — LS24D27C relays Figure 6c — LS60D22C relay 1500 Apeak 1000 Non-Repetitive 500 Repetitive with initial Tj = 70°C 0 0.01 0.1 t(s) 1 10 Figure 6e — LS60D30C relay © 2016 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com LS Page 3 LS\092014\Q3 Series LS 30A to 600 Vac SIP Package DC Control MOUNTING EXAMPLES Heat sinks references: FW100: L=100mm about 4°C/W (1SSR) without ventilation (3.6°C/W with 4SSRs ) FW150: L=150mm about 3°C/W (1SSR) without ventilation (2.6°C/W with 6SSRs ) Supports additional heat sink if necessary Clips reference: L19101 Thermal grease 2 (51) 0.311 ±006 (7.9 ± 0.15) 0.16 (4) to maintain isolation Figure 7a — Thermal heat sinks with mounting clips; dimensions in inches (mm) M3 1.04 (26.5) 0.16 (4) to maintain insulation clips: L19100 Thermal grease Printed circuit board Figure 7b — Clips with screws on standard heat sinks; dimensions in inches (mm) In each case, allow 0.16 in. (4mm) between the printed circuit board and the heat sink to keep a correct insulation between input to output (0.16 in./4mm insulated washer). To maintain a good contact between the SSR and the heat sink, use thermal grease. LS Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2016 TELEDYNE RELAYS LS\092014\Q3 Series LS 30A to 600 Vac SIP Package DC Control MECHANICAL SPECIFICATION L19101 CLIP –.01 Figure 9a – Clip for FW100 and FW150 heat sinks .28 (7) .99 (25.2) –.01 –.01 1.86 (47.2) M4 1.18 (30) = = M4 Length: FW100 = 3.94 (100) = = .31 (7.9) FW150 = 5.9 (150) –.01 Thermal grease Figure 8 – FW100 and FW150 heat sinks; dimensions in inches (mm) Relay .16 (4) FW100 heat sink with Max Clip System* Rth = 3.6°C/W (4 SSRs) Rth = 4°C/W (1 SSR) ±.01 .07 (1.7) FW150 heat sink with Max Clip System* Rth = 2.6°C/W (4 SSRs) Figure 9b – Mounting with L19101 clip; dimensions in inches (mm) Rth = 3°C/W (1 SSR) *The Max Clip System of Aavid Thermalloy, patented worldwide L19100 CLIP Thermal grease Relay Figure 10a – Clips with screws for other heat sinks 1.04 (26.5) M3 .16 (4) ±.01 .07 (1.7) Figure 10b – Mounting with L19100 clip; dimensions in inches (mm) NOTES 1. 0.16-inch (4mm) mounting washer must have correct insulation between input to output. © 2016 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com LS Page 5 LS\092014\Q3 Series LS 30A to 600 Vac SIP Package DC Control LS WITH HS1 HEAT SINK Tolerances: +–0.1 .87 (22) .5 (12.7) 1.4 (35.7) 1.1 (28) .25 (6.3) 4 3 .3 (7.5) .95 (24.2) 1.72 (43.6) 1 Ø1 .5 (12.7) .2 (5.08) .07 (1.73) 2 .31 (7.83) .4 (10.16) Figure 11 – LS with HS1 WEIGHT: 1.06 oz. (30g) Top view INPUT (CONTROL) SPECIFICATION Min Max Units 4 14 Vdc 6.5 30 mAdc Control Range LS24D16C-HS1 .1 (2.54) Hole Ø 1.6 Input Current Range LS24D16C-HS1 Figure 12 — LS relays with HS1; dimensions in inches (mm) LOAD CURRENT DERATING CURVE Must Turn-Off Voltage All relays 1 Vdc 26 Input Resistance (Typical) LS24D16C-HS1 440 Ohms Load Current (Arms) 24 22 20 Forced air cooling with heat sink temperature 85°C max 18 16 14 12 10 8 Convection cooling 6 4 2 0 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (°C) Figure 13a — LS24D16X-HS1 relays LS Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2016 TELEDYNE RELAYS LS\092014\Q3 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Teledyne Relays: LS24D16C-HS1 LS60D30C LS60DC10C-21