369650 DALI Power Module spec submittal

advertisement
DALI® Power Module
LQSE-2DAL-D
DALI® Fixture Controller
369650b 1 10.22.13
Features
•Provides power for two buses of DALI® compliant
digital addressable loads (up to 250 mA per bus).
L
N
NEC®
Class 2
NEC® Class 2
IEC PELV
Ta > 65 ºC
DALI® Power Module | Módulo de Potencia DALI® | Module d’Alimentation DALI®
Test
Prueba
Tester
120 V~ 50/60 Hz 120 mA
u
LQSE-2DAL-D
1.800.523.9466
243C IND.CONT.EQ.
230 V~ 50/60 Hz 80 mA
Ta ≤ 65 °C
+44.(0)20.7702.0657
Z096
8 mm
65/75 ºC Cu Al
0,5 N•m (5 in-lbs)
www.lutron.com
•Each DALI® Bus can control a maximum of
16 zones.
•Power failure memory retains programming in
the event of a power loss.
DALI® Power Module (LQSE-2DAL-D)
•DALI® Power Module can be used in a
HomeWorks® QS system to control and manage
light in an entire home or building.
DALI® Bus 1
DALI® Bus 2
Ballast
Ballast
Ballast
Ballast
HomeWorks® QS
Wallstation
DALI ®
Power Module
120 / 230 V~
Control Power
Power
Module
HomeWorks® QS
Processor
QS
Contact
Closure
Interface
Up to 64
ballasts on
each Bus
GRAFIK
Eye® QS
Up to 100
total QS
devices
QS Link
Sivoia® QS
Shade / Drapery
QS
Power
Supply
DALI is registered trademark of ZVEI-Zentralverband Elektrotechnik
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
500-15538 Rev. A
DALI 1 DALI 2
COM
QS
MUX
The DALI® Power Module is a DIN-rail mounted
controller for DALI®-compliant Digital Addressable
loads. It provides DALI® bus power and control
for two independent DALI® buses with up to
64 ballasts each.
MUX
DALI® Power Module
Page
1
DALI® Power Module
LQSE-2DAL-D
DALI® Fixture Controller
369650b 2 10.22.13
Specifications
Power
•120 V~ 50/60 Hz 120 mA
•230 V~ 50/60 Hz 80 mA
•Lightning strike protection meets ANSI/IEEE standard
62.31-1980. Can withstand voltage surges of up to
6000 V~ and current surges of up to 3000 A.
•Stand by power: 7 W
•BTUs / hour when fully loaded: 24
•DALI® Bus Output: 16 V- 250 mA maximum per bus.
Standards
•Lutron Quality Systems registered to ISO 9001.2008.
•CE
•C-Tick S
•UL
•cUL
•NOM
Environment
•Surrounding Air Temperature Range: 0 ºC to 65 ºC
(32 ºF to 149 ºF).
•Relative Humidity: less than 90% non-condensing.
•Calibration point maximum: 75 ºC (167 ºF)
•For indoor use only.
Terminals
•Mains Wiring: 1.0 mm2 to 4.0 mm2
(18 AWG to 12 AWG)
•DALI Bus Wiring: 0.5 mm2 to 1.5 mm2
(20 AWG to 14 AWG)
•QS Link Wiring: 1.0 mm2 (18 AWG)
•Minimum wire temperature rating = 65 °C (149 ºF),
Cu only
Mounting
•Intended to mount within an IP20 (minimum) rated
consumer panel or breaker panel with integrated DIN
rail and dead cover
•Width = 9 DIN modules (161.7 mm or 6 3⁄8 in).
DALI® Buses
•Up to 64 DALI® compliant loads on each bus can be
addressed and grouped into 16 zones.
•DALI ® Power Module supplies 250 mA to power
each bus.
•DALI® Bus wires are polarity insensitive and
topology-free.
QS Link Limits
•A QS link in a HomeWorks® QS system can have up
to 512 zones (outputs) and 100 devices. A ballast or
driver counts as 1 zone unless specifically grouped
into zones from the HomeWorks® QS software.
•Each DALI® Power Module counts as one device
toward the 100 device limit.
•A maximum of 8 fully loaded DALI® Buses may be
connected to a single QS link.
HomeWorksR QS Wallstations
•HomeWorks® QS wallstations can be configured to
control DALI® Power Modules with the HomeWorks®
QS programming utility.
•LED indicator displays the status of programmed lights.
Troubleshooting and Maintenance
Features
•Maintains redundant memory of ballast programming
for ease of single or multiple ballast replacement.
•To verify DALI® lights connected to DALI® bus 1 and
bus 2:
– Enter Test Mode: Press and hold Test button on
the DALI® Power Module until the Test LED starts
flashing.
–T
est: Each press of either the DALI 1 or DALI 2
button will cycle the lights between high-end,
low-end, flash and off for that bus.
–E
xit Test Mode: Press and hold Test button until
Test LED stops flashing.
Programming and Compatibility Requirements
•The LQSE-2DAL-D can only be used with the
HomeWorks® QS system.
•Setup and programming of the DALI® Power Module
is done through the HomeWorks® QS programming
software.
DALI is registered trademark of ZVEI-Zentralverband Elektrotechnik
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
2
DALI® Power Module
LQSE-2DAL-D
DALI® Fixture Controller
369650b 3 10.22.13
Overview of Wiring Terminals and Mechanical Dimensions
IEC PELV / NEC®
Class 2
NECR Class 2
QS
Link
DALI®
Bus 1*
DALI®
Bus 2*
500-13431 Rev. B
L
N
DALI 1 DALI 2
NEC®
Class 2
NEC® Class 2
IEC PELV
Ta > 65 ºC
DALI® Power Module | Módulo de Potencia DALI® | Module d’Alimentation DALI®
Test
Prueba
Tester
120 V~ 50/60 Hz 120 mA
u
500-15538 Rev. A
COM
MUX
QS
MUX
Z096
N1771
LQSE-2DAL-D
1.800.523.9466
243C IND.CONT.EQ.
230 V~ 50/60 Hz 80 mA
Ta ≤ 65 °C
Z096
8 mm
89.7 mm
(3 1⁄2 in)
65/75 ºC Cu Al
+44.(0)20.7702.0657
0,5 N•m (5 in-lbs)
www.lutron.com
161.7 mm
(6 3⁄8 in)
Mains
Wiring
* Wire according to local codes.
60.6 mm
(2 3⁄8 in)
DALI is registered trademark of ZVEI-Zentralverband Elektrotechnik
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
3
DALI® Power Module
LQSE-2DAL-D
DALI® Fixture Controller
369650b 4 10.22.13
Test
Prueba
Tester
120 V~ 50/60 Hz 120 mA
LQSE-2DAL-D
1.800.523.9466
243C IND.CONT.EQ.
Ta ≤ 65 °C
+44.(0)20.7702.0657
Z096
8 mm
65/75 ºC Cu Al
0,5 N•m (5 in-lbs)
www.lutron.com
L
N
Ta > 65 ºC
DALI®
Test
Prueba
Tester
120 V~ 50/60 Hz 120 mA
u
COM
230 V~ 50/60 Hz 80 mA
®
®
®
LQSE-2DAL-D
®
Emergency Lighting Applications
1.800.523.9466
243C IND.CONT.EQ.
230 V~ 50/60 Hz 80 mA
Ta ≤ 65 °C
500-15538 Rev. A
NEC®
Class 2
DALI® Power Module | Módulo de Potencia DALI® | Module d’Alimentation DALI®
500-15538 Rev. A
COM
DALI 1 DALI 2
NEC® Class 2
IEC PELV
Ta > 65 ºC
u
Wiring from Distribution to PowerTest
Module LQSE-2
230 V~
•Turn off all circuit breakers or isolators feeding the
www.lutron.
Power
Power Module unit at the distribution panel.
L N
wires from a8 mm
•Run line, neutral, and earth/ground
feed to the DALI® Power Module.
QS
DALI 1 DALI 2
to 12 AWG)
• Use 1.0 mm2 to 4.0 mm2 (18 AWG
NEC
NEC Class 2
conductors
(depending on breaker rating) toClass
feed
2 the
IEC
PELV
mains wiring. The device draws less than 120 mA
Power Module | Módulo de Potencia DALI
| Module
(120
V~)d’Alimentation
and 80mADALI
(230 V~).
MUX
N
Hi Temp Power M
MUX
L
MUX
QS
MUX
Wiring: Mains Voltage
•Use normal (non-essential)
power only to power the
+44.(0)20.7702.0657
Al
0,5
N•m
(5 in-lbs) www.lutron.com
ºC Cu
Power
Module.
DALI®65/75
•When normal power drops out, the DALI® Power
Module will not power the DALI® Buses. When this
occurs, ballasts powered from emergency feeds go to
their emergency mode, full light output by default.
Z096
8 mm
Mains Wiring and IEC PELV / NEC® Class 2
Separation
•The DALI® Power Module is designed to separate
mains wiring from IEC PELV / NEC® Class 2 circuits.
•Follow appropriate local and national codes to avoid
violating required separation guidelines.
N
L
Distribution
Panel
– Earth/Ground
N – Neutral
L – Mains/Line
DALI is registered trademark of ZVEI-Zentralverband Elektrotechnik
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
4
DALI® Power Module
LQSE-2DAL-D
DALI® Fixture Controller
369650b 5 10.22.13
L
N
DALI 1 DALI 2
NEC®
Class 2
NEC® Class 2
IEC PELV
Ta > 65 ºC
DALI® Power Module | Módulo de Potencia DALI® | Module d’Alimentation DALI®
Test
Prueba
Tester
120 V~ 50/60 Hz 120 mA
u
500-15538 Rev. A
COM
MUX
QS
MUX
Wiring: DALI® Bus
LQSE-2DAL-D
Ta ≤ 65 °C
1.800.523.9466
243C IND.CONT.EQ.
230 V~ 50/60 Hz 80 mA
Z096
8 mm
65/75 ºC Cu Al
+44.(0)20.7702.0657
0,5 N•m (5 in-lbs)
www.lutron.com
DALI®
Bus 2
DALI® 2
DALI® 1
DALI® 2
DALI 1 DALI 2
NEC®
Class 2
DALI® Wiring
• DALI® wiring is not SELV.
• DALI® wiring may be treated as mains voltage, and
thus can be run within the same sheathing.
• Ensure that there is no greater than a 2 V ~ drop
between the DALI® Power Module and the end of the
DALI® Bus.
• Consult all national and local electrical codes for
separation requirements.
Wire Gauge
Maximum DALI®-compliant
Bus Wire Length
1.5 mm2 (14 AWG)
300 m (984 ft)
0.75 mm2 (18 AWG)
150 m (492 ft)
0.5 mm2 (20 AWG)
100 m (328 ft)
500-15538 Rev. A
DALI®
Bus 1
DALI® 1
The DALI® Power Module will supply power for two
independent DALI® Bus, which supports a maximum
of 64 ballasts per bus.
Lutron Qualified DALI® Ballasts
d’Alimentation DALI®
96
Lutron requires
that all DALI® devices that are intended to be used with a LutronR DALI controller must be
1.800.523.9466
pre-tested
by
Lutron
+44.(0)20.7702.0657 and determined to be compatible before being used on a project.
5 ºC Cu Al For
0,5 N•m (5 in-lbs)
www.lutron.com
R qualified DALI® ballasts please refer to Application Note #482 for more information.
a complete
list of Lutron
DALI is registered trademark of ZVEI-Zentralverband Elektrotechnik
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
5
DALI® Power Module
LQSE-2DAL-D
DALI® Fixture Controller
369650b 6 10.22.13
Wiring: QS Link
L
N
DALI 1 DALI 2
NEC®
Class 2
NEC® Class 2
IEC PELV
Ta > 65 ºC
DALI® Power Module | Módulo de Potencia DALI® | Module d’Alimentation DALI®
Test
Prueba
Tester
120 V~ 50/60 Hz 120 mA
u
•Link communicates using IEC PELV / NEC®
Class 2 wiring.
500-15538 Rev. A
COM
MUX
QS
MUX
IEC PELV / NEC® Class 2 QS Link Wiring
•Follow all applicable national and local codes for
proper circuit separation and protection.
LQSE-2DAL-D
1.800.523.9466
243C IND.CONT.EQ.
230 V~ 50/60 Hz 80 mA
+44.(0)20.7702.0657
Z096
Ta ≤ 65 °C
65/75 ºC Cu Al
8 mm
0,5 N•m (5 in-lbs)
www.lutron.com
•Wiring may be daisy chained or t-tapped.
•Total length of QS link must not exceed 610 m
(2000 ft).
•Do NOT connect terminal 2.
•Wire Gauge
–Power (terminals 1 and 2): 1 pair 1.0 mm( (18 AWG)
–Data (terminals 3 and 4): 1 pair 0.5 mm( to 1.0 mm(
(22 AWG to 18 AWG) twisted and shielded
(1) COM
(2)
No Connection
NEC® Class 2
IEC
(3)PELV
MUX
(4) MUX
DALI 1 DALI 2
NEC®
Class 2
500-15538 Rev. A
COM
MUX
QS
MUX
–Can use Lutron® cable GRX-CBL-346S-500
r Module | Módulo de Potencia DALI® | Module d’Alimentation DALI®
AL-D
/60 Hz 120 mA
1.800.523.9466
243C IND.CONT.EQ.
/60 Hz 80 mA
Z096
8 mm
65/75 ºC Cu Al
+44.(0)20.7702.0657
0,5 N•m (5 in-lbs)
www.lutron.com
DALI is registered trademark of ZVEI-Zentralverband Elektrotechnik
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts
®
Job Name:
Job Number:
S p e c i f i c at i o n S u b m i t ta l
Model Numbers:
Page
6