T h e # 1 S e l l i n g M o d u l a r W i r i n g S o l u t i o n S i n c e 1 9 7 7 The QUICKEST way to wire. For recessed-ceiling, open-ceiling and power applications. the RELOC Advantage ® • Innovative, patented products • Fast estimating and simple ordering • Lowest total job cost • Easy fixture relocation • Easy project management • Safety and reliability RELOC® Wiring Solutions In today’s fast-paced construction market, staying on schedule and under budget is tougher than ever. Every job demands wiring solutions that reduce installation time and adapt to changes, whether they occur during construction or after a building is occupied. With rising labor costs and the shortage of qualified electricians, traditional wiring methods no longer measure up. RELOC Wiring Solutions from Acuity Brands Lighting has been the leader in modular wiring since 1977. Reloc offers three unique wiring systems that are fast, easy and effective: Quick-Flex® wiring for recessed ceiling lighting installations, OnePass® system for open-ceiling lighting installations and System 820 for specialty lighting and power applications. Reduce, Reuse, Recycle. . .RELOC® REDUC E USE RE Y REC CLE RELOC products are a greener solution than traditional wiring. RELOC products minimize installation time and construction waste while maximizing productivity, reusability and the use of recycled materials. Please see www.acuitybrandslighting.com/sustainability for more information. Lowest Total Job Cost Easy Fixture Relocation RELOC components snap together in a frac- Complete tion of the time it takes to wire a fixture with and inexpensively by reusing RELOC conventional wiring methods — and require components. Simply unplug the original less labor and fewer materials. Installation system, time is reduced by up to 66 percent, result- reconnect the system. Quick changes ing in significantly reduced total job cost. minimize facility down-time. Easy Project Management Safety and Reliability RELOC wiring enhances the ability to All RELOC components are 100-percent plan and manage a tight schedule. Since electrically tested. Safety features such RELOC wiring is installed with fixtures in as dead-fronted contacts are designed to the finish phase, labor, material costs and comply with UL183 and CSA 22.2 203.1 trade conflicts are reduced during the (standard for manufactured wiring sys- critical rough-in stage. tems) and 2008 NEC 410.130 (G) and wiring relocate changes the quickly fixtures and Quick-Flex® OnePass® CEC 30-308 (ballast disconnective means) Fast Estimating and Simple Ordering while following standard safety practices. RELOC estimating tools provide fast project System 820 estimates and simple ordering, eliminating the need for time-consuming factory drawings. RELOC Wiring Offers Lowest Total Job Cost vs. Traditional Wiring Methods Manufactured wiring systems are described in NEC 604 and Canadian CEC 12-2500. All products are UL Listed, NYC Approved and C-UL Listed or CSA Certified. New York City Approved Calendar Numbers 47802, 48072 and 48273 1 ONE Quick-Flex® recessed-ceiling wiring is faster and easier to install than MC Cable® or other modular wiring systems. With only three basic components, the Quick-Flex system snaps together in a fraction of the time it takes to wire a fixture with MC Cable. There is no need for tools, factory estimating or drawing services. Due to faster installation, labor costs are dramatically reduced, cutting down the total job cost. The Quick-Flex system is ideal for wiring lay-in troffers, parabolics, downlights, indirect fixtures and emergency lighting equipment in office buildings, schools and retail stores. Quick-Flex Standard Features • The Quick-Flex fixture combo is shipped standard with an access plate (as shown in the photo below). These access plates have one pre-punched knockout to speed the installation of Lithonia troffers and parabolics. For downlights or non-Lithonia fixtures, discard access plate and install fixture cable directly to any 1/2” knockout. • UL Listed autoground – Fixtures are grounded automatically as soon as the access plate is snapped in place. No ground leads to connect. • Auto-latching springs allow for an easy, secure connection and prevent accidental disengagement. Factory-Installed Combo Option The Quick-Flex fixture cable (QFC) can be prewired to the fixture in the factory. Both the fixture and Quick-Flex cable are shipped together. This reduces the amount of time spent sorting materials at the job site. It also cuts on-site disposal costs. This option is ideal for jobs with 100 or more fixtures of the same type, using the same Quick-Flex fixture cable. See page 3 for ordering information. Ask your local Acuity Brands Lighting representative for your RELOC 1-2-3 price guarantee. TWO 2 Quick-Flex Wiring is Easy to Estimate 1) One QFC cable per fixture 2) One QC converter per circuit run 3) 10% QE cables and 3% QS splitters (spare parts) Dust covers are not included with combo option and must be ordered separately. Switching Solutions If MC Cable is used between switches, Quick-Flex wiring can provide a simple and efficient link from the switchbox to the fixtures on the switched circuit. For best results, install Quick-Flex switch drops during the rough-in stage. Add a Quick-Flex extender between the switch drops during the finish phase when the fixtures and QFC cables are installed. 35% Cost Savings = ______ MC Cable Quick-Flex Materials $385.00 $545.00 Labor $677.00 $136.00 Total* $1062.00 $681.00 * Based on a typical single-circuit, 30-fixture application on 10-foot centers with a $55/hr. labor rate (USD). 35% Savings On Total Installed Cost How To Order Fluorescent Combo Option Lithonia Lighting fixture with Quick-Flex fixture cable attached and prewired. Example: RELOC QFC277 12/3G11 becomes luminaire option QFC311GAB 2SP8 G 3 32 A12 347 GEB10IS QFC311GAB Specifying wiring option: Wiring Option 2 conductors (1 hot) ex: QFC2 (length) xx 3 conductors (2 hot) ex: QFC3 (length) xx A All ballasts/inverters on "A" circuit. B All ballasts/inverters on "B" circuit. AB Outboard lamps on "A", inboard on "B" (If fixture contains 2 ballasts plus an inverter, the inverter will be located at the access plate. Not connected to a QFC supplied circuit.) AE NW Access plate with knockouts installed in fixture. RELOC included with fixture, not wired. All ballast(s) on "A", inverter on "B". Access plate with knockouts installed in fixture. RELOC included with fixture, not wired. 3 THREE OnePass® open-ceiling wiring simplifies the installation of high bay fixtures. Traditional hardwiring requires three or more passes to install conduit, pull wire and hang fixtures. Using the OnePass system, only three basic components and one pass are needed. Faster installation reduces labor costs and the total job cost. Plus, there is no need for factory estimating or drawing services. The OnePass system is ideal for installing HID­­and fluorescent fixtures in manufacturing facilities, warehouses, retail facilities and any other open-ceiling fixture applications. OnePass Standard Features • The OnePass system is listed for open accessible ceilings and dry locations, meeting or exceeding the UL 183 and 22.2 203.1 requirements, the National Electrical Code and Canadian Standards. • All components are easy to install and relocate, featuring easy-to-grip cable heads and self-latching springs that simply plug together. OnePass Factory-Installed Option Use the following guidelines to order fixtures with OnePass pre-installed. • Add OCS to the description: Example IB 454 277 LP835A OCS. Consult factory for other options. • For four or five conductor fixture drops, follow the same guidelines as above, except tap positions must now be specified for the OCU product. Example: OCU122N = 5' white cord with two hots, two dedicated neutrals and a ground. Example: OCU2310 = 10' white cord with two hots and one neutral. • OnePass wiring is rated at 20A with 90ºC 12 AWG conductors. The OnePass OC2 cable also is available in a 10AWG, 20A option to reduce voltage drop on longer runs. • All components are keyed to prevent different voltages from connecting, and color-coded cable heads allow for easy identification. 25% Savings On Total Installed Cost FOUR 4 NEW Circuit Selection at Every Fixture Position 1 G 1 2 3 N The OCS is a polarized plug-in connection for industrial fixtures, featuring a patented thumbslide action. Just choose the desired hot conductor(s) needed to energize each fixture. Simply slide the circuit selector to position 1, 2 or 3 and plug the fixture into the system. No more worrying about coordinating different-circuited fixtures. The OCS permits removal of any fixture from the branch circuit without additional components or interruption in the branch circuit. All cables now available in custom colors. For details, contact the factory at 1-800-541-4750. 25% Cost Savings = ______ Pipe & Wire OnePass Materials $700.00 $1267.00 Labor $2062.00 $825.00 Total* $2762.00 $2092.00 * Based on a typical single-circuit, 30-fixture application on 20-foot centers with a $55/hr. labor rate (USD). Ask your local Acuity Brands Lighting representative for your Reloc 1-2-3 price guarantee. OnePass Wiring is Easy to Estimate 1) One OCS per fixture 2) One OC2 cable for each fixture 3) One OC per circuit run 5 FIVE Quick-Flex® Components Recessed-Ceiling Lighting System Example: QC120 12/3G QC QC - Converter Provides interface between hardwiring and Quick-Flex wiring at the homerun location. 12/3G Family Voltage Size and no. of conductors QC Q uickFlex converter 120 120V 277 277V 347 347V 12/3G Family Voltage Size and no. of conductors QSFC Q uickFlex starter fixture cable 120 120V 277 277V 347 347V 12/2G 12/3G QSFC QSFC - Starter Fixture Cable1 Combination of converter (QC) and fixture cable (QFC). Length Optional ground lead 09 9 feet G No. 18 AWG ground 11 11 feet lead dropped to 13 13 feet fixture (REQUIRED 15 15 feet IN CANADA) QFC QFC - Fixture Cable1 Male/female cable provides power from fixture to fixture. Access plate is preattached. Family Voltage Size and no. of conductors Length Optional ground lead 120 120V 277 277V 347 347V 12/2G 12/3G 09 9 feet 11 11 feet 13 13 feet 15 15 feet G No. 18 AWG ground lead dropped to fixture (REQUIRED IN CANADA) Family Voltage Size and no. of conductors Length QE Q uickFlex extender 120 120V 277 277V 347 347V 12/2G 12/3G 09 9 feet 11 11 feet 15 15 feet 21 21 feet Voltage Size and no. of conductors 120 120V 277 277V 347 347V 1LEVEL 2LEVEL 1LEVEL/N QFC Q uickFlex fixture cable QE QE - Extender Male/female cable provides additional length anywhere within the system. QSD QSD - Switch Drop Provides local switched power for fixtures as well as the ability to carry on unswitched power through the use of a QE. Family QSD Q uickFlex switch drop QPT QPT - Power Tee Provides hardwire connection to any electrical device. Family QPT Q uickFlex power tee 12/3G Voltage Size and no. of conductors Length 120 120V 277 277V 347 347V 12/3G 01 1 foot 09 9 feet 15 15 feet QS QS - Splitter Male/female component that can be used anywhere in the system. Separates branch circuit into two directions. SIX 6 Length 01 1 foot 09 9 feet 12/3G Family Voltage Size and no. of conductors QS Q uickFlex splitter 120 120V 277 277V 347 347V 12/3G Quick-Flex Dust Cover Dust cover is required to protect unused ports in a RELOC system per NEC Article 604.7. QUICK FLEX Dust cover J50 NOTES: 1 Furnished with poke home connectors for easy connection to fixture wires. OnePass® Components Open-Ceiling Lighting System Example: OC 277 12/4G OC 12/4G Family1 OC OnePass converter OSC2 Family1 Voltage 120 208 240 277 347 480 OSC2 OnePass starter cable Size and no. of conductors3 Voltage 120 208 240 277 347 480 12/4G 120V 208V2 240V2 277V 347V 480V2 Cable length Size and no. of conductors 120V 208V2 240V2 277V 347V 480V2 09 15 21 25 31 12/2G 12/3G 12/4G 10/2G 10/3G 10/4G 9 feet 15 feet 21 feet 25 feet 31 feet OC - Converter Provides interface between hardwiring and RELOC wiring at homerun location. OSC2 - Starter Cable Provides interface between hardwiring and RELOC wiring system. OC2 Family1 Voltage OC2 OnePass twoport cable 120 208 240 277 347 480 Size and no. of conductors Cable length 12/2G 12/3G 12/4G 10/2G 10/3G 10/4G 120V 208V2 240V2 277V 347V 480V2 09 15 21 25 31 9 feet 15 feet 21 feet 25 feet 31 feet OCS Family4 Voltage OCS OnePass cord with circuit selector 120 208 240 277 347 480 120V 208V2 240V2 277V 347V 480V2 Cable length Cord colors5 05 5 feet 10 10 feet 15 15 feet 20 20 feet WH White cord BK Black cord OC2 - Two-Port Cable Provides feed-through and tap in one component. Acts as an extension cable between fixture connections. OCS - Circuit Selector A polarized plug-in connector for industrial fixtures. Allows on-site circuit selection of desired hot conductor(s). Prewired by fixture manufacturer or field installed by contractor. OCU Family1,4 OCU OnePass cord unselectable Tap position Voltage 120 120V TAP2 2 208 208V2 TAP12 1 and 2 240 240V2 TAP34 3 and 4 347 347V TAP1 1 480 480V2 TAP3 3 TAP23 2 and 3 TAP123 1, 2 and 3 Cord colors5 Cable length 05 10 15 20 5 feet 10 feet 15 feet 20 feet WH White cord BK Black cord OCU - Cord Unselectable A polarized, non-circuit selectable plug-in connection for industrial fixtures. Prewired by fixture manufacturer or field installed by contractor. OD Family1 OD OnePass drop cable Voltage 120 208 240 277 347 480 Size and no. of conductors 12/2G 12/3G 12/4G 120V 208V2 240V2 277V 347V 480V2 OSS Family1 OSS OnePass splitter splice Cable length 05 10 15 20 5 feet 10 feet 15 feet 20 feet OD - Drop Cable Allows miscellaneous devices (exits, etc.) to become part of the system. 12/4G Voltage 120 208 240 277 347 480 Size and no. of conductors3 12/4G 120V 208V2 240V2 277V 347V 480V2 OnePass Dust Cover Dust cover is required to protect unused ports in a RELOC system per NEC Article 604.7. RDC3 METAL Dust cover CSA/UL J50 OSS - Splitter Splice Male/female component that can be used anywhere in the system. Separates branch circuit into two directions. NOTES: 1 For two neutral applications, specify 2N (10/4G and 12/4G only). Consult factory for other options. Please consult factory when ordering 208V, 240V or 480V. Use 12/4G product for 10GA, 20A systems. 16AWG rubberized cord rated for 600V, 105ºC with fully rated ground conductor. White cord standard. Black cord requires longer lead time. 2 3 4 5 7 SEVEN System 820 Specialty Power and Lighting System Example: CD 120 F CD CD - Circuit Distributor Provides interface between hardwiring and RELOC wiring system. Family CD Voltage No. of conductors 120 120V D Three 277 277V E Four 347 347V F Five CE CE - Cable Extender Male/female cable that provides additional length anywhere throughout the RELOC system. U Family Voltage CE 120 120V 277 277V 347 347V No. of conductors D Three E Four F Five Male/female cable, provides power from fixture to fixture. Attaches to access plate or through 1/2” trade-size knockout by means of poke home connectors. Family Voltage SSC 120 120V 277 277V 347 347V SS SS - Splitter Splice Used to split branch circuit into two directions in commercial or power applications. Family Voltage SS 120120V 277277V 347347V CSU CSU - Circuit Selector Unit Provides wiring of any device through 1/2" trade-size knockout. CSU uses No. 12 AWG leads, allowing full circuit access. Family CSU Factory keying U Options Cable length 09 11 15 21 25 9 feet 11 feet 15 feet 21 feet 25 feet IGW Isolated ground wire; available with 120V and F conductor only 2NTwo circuit, two neutral; F conductors only U SSC SSC - Standard Selector Cable Options IGW Isolated ground wire; available with 120V and F conductor only 2NTwo circuit, two neutral; F conductors only Voltage No. of conductors D Three E Four F Five Factory keying U F U No. of conductors Factory keying F Five U F U No. of conductors Factory keying 120 120V F Five 277 277V 347 347V U Options Cable length 09 11 13 15 9 feet 11 feet 13 feet 15 feet Options IGW Isolated ground wire; available with 120V and F conductor only 2NTwo circuit, two neutral; F conductors only Options IGW Isolated ground wire; available with 120V and F conductor only 2NTwo circuit, two neutral; F conductors only 820 Dust Cover Dust cover is required to protect unused ports in a RELOC system per NEC Article 604.7. RDC3 METAL Dust cover CSA/UL J50 EIGHT 8 2NTwo circuit, two neutral; F conductors only G Ground lead with lug terminal (REQUIRED IN CANADA) System 820 Specialty Power and Lighting System Number of duplexes (blank) One 2 Two DUP 120 Series Voltage DUP 120 120V A Hot receptacle position Interface component F Family No. of conductors FFive1 Voltage Family RRCA2 Voltage 120 120V 208 208V 347 347V 480 480V 011 foot 055 feet Options IGW Isolated ground wire; available with E and F conductors only (add only if required) 1 One 2 Two 3 Three Tap position Drop type 1 1 2 2 3 3 121 and 2 131 and 3 232 and 3 123 1, 2 and 3 A Armored Options IGWIsolated ground wire; available with 120V; E and F conductors only Cable 2N Two circuit, two length neutral; F conductors only 01 1 foot 03 3 feet 09 9 feet 15 15 feet F RRCA DUP - Duplex Receptacle Cable length The DUP is a prewired power receptacle outlet box that integrates with a RELOC system. The DUP can be used to manage phase loading on power receptacle applications. Pre-order the appropriate number of receptacles for each circuit prewired from the factory. A PT 120 120V 277 277V 347 347V A Armored D Three E Four F Five PT Power tee1 DC Drop cable PT Drop type No. of conductors No. of conductors FFive Tap position 123 1, 2 and 3 (120V or 277V) 1234 1, 2, 3 and 4 (208V or 480V) 05 WH Cable length Cord color 05 5 feet WH White PT - Power Tee Provides hardwire connections to any electrical device. RRCA - Replacement RELOC Cord Assembly Ideal for retrofitting projects done with old RELOC system. Prewired by fixture manufacturer or field installed by the contractor. U DC Family Voltage DC 120 120V 277 277V 347 347V No. of conductors D Three EFour FFive Factory keying U Cable length 09 11 13 15 9 feet 11 feet 13 feet 15 feet Options IGW Isolated ground wire; available with 120V and F conductor only 2N Two circuit, two neutral; F conductors only DC - Drop Cable Provides integration of other electrical devices into the 820 system, such as power outlets and power strips. NOTES: 1 2 Power Tee (PT) is available in five-conductor only with DUP product. RRCA is sold only with white cord and five-wire configuration. 9 NINE REDUC E USE RE Y REC CLE Reduce, Reuse, Recycle. . .RELOC® RELOC products are a greener solution than traditional wiring. RELOC products minimize installation time and construction waste while maximizing productivity, reusability and the use of recycled materials. Please see www.acuitybrandslighting.com/sustainability for more information. One Lithonia Way, Conyers, GA 30012 | TEL 800.241.4750 | FAX 770.808.8650 | www.relocwiring.com © 2011 Acuity Brands Lighting, Inc., All Rights Reserved. 06/11 R6980 Form No. 670.208