Salzer Electronics Limited Samichettipalayam Coimbatore - 641 047, INDIA. Tel: +91 422 4233600/2692531. Fax: + 91422 2692170. Email: salzer@salzergroup.com, sales@salzergroup.com. Website: www.salzergroup.com n o h t c t i Sw he Bes t o t Intertek Cam Operated Rotary Switches Cam Operated Rotary Switches Cam Operated Rotary Switches used to perform Make and Break operation in a sequential way by rotating the switch to different positions. The Cam, which closes and opens the contacts, has rotary movement to multiple positions, thereby multiple Circuit functions can be controlled. Further, the flexibility in the switch type selection covering various current / voltage ratings and options to select the number of contacts, is added advantage. This ensures that a right switch is chosen for the desired application. CAM Switches thus offer complete design flexibility to assemble complex switching programs, contact ratings and customize all switching applications. Moreover the Cam Switches are suitable for AC as well as DC switching applications. The basic operating mechanism of Cam Switch is required to suit intended application coupled with “Quick-Make”, “Quick-Make-Quick-Break” and “Spring Return” operating mechanisms are offered to cover wide range requirements. The Cam Switches offers versatile mounting options in addition to Standard Panel/Flush Mounting and other special features like single hole, door interlocking, padlock, Lock and Key for various needs. The wide option such as type of Knob, Front plate Color and customized marking on the Marking Plate gives compatible to the panel design and thus eliminates the need of the separate label on the panel. The superior quality of engineering materials and “Double Butt” contacts with silver bimetal on copper/brass provide stable electrical performance. The high-grade engineering plastics with high tracking index like Nylon, Celcon and glass filled polyamide for the components ensures greater mechanical strength. Advanced manufacturing processes for Cam Switch components under stringent quality conditions ensures durability, reliability and enhanced life and safe operations for a very long time. 02 Cam Operated Rotary Switches Contents Introduction 02 Construction 04 Technical Specifications 05 Isolator Switches 06 Changeover Switches with OFF 07 Changeover Switches without OFF 08 Multistep Switches with OFF 09 Multistep Switches without OFF 10 Instrumentation Selector Switches 11 Motor Control Switches 13 Gang Switches 15 Control Switches 16 Mountings 17 Knobs and Handles 22 Accessories 23 Customised Programme 24 Ordering Code 25 Breaker Control Switches 26 Installation Procedure - Standard Switches 28 DC Switches 29 03 Cam Operated Rotary Switches Cam Operated Rotary Switches used to perform Make and Break operation in a sequential way by rotating the switch to different positions. The Cam, which closes and opens the contacts, has rotary movement to multiple positions, thereby multiple Circuit functions can be controlled. Further, the flexibility in the switch type selection covering various current / voltage ratings and options to select the number of contacts, is added advantage. This ensures that a right switch is chosen for the desired application. CAM Switches thus offer complete design flexibility to assemble complex switching programs, contact ratings and customize all switching applications. Moreover the Cam Switches are suitable for AC as well as DC switching applications. The basic operating mechanism of Cam Switch is required to suit intended application coupled with “Quick-Make”, “Quick-Make-Quick-Break” and “Spring Return” operating mechanisms are offered to cover wide range requirements. The Cam Switches offers versatile mounting options in addition to Standard Panel/Flush Mounting and other special features like single hole, door interlocking, padlock, Lock and Key for various needs. The wide option such as type of Knob, Front plate Color and customized marking on the Marking Plate gives compatible to the panel design and thus eliminates the need of the separate label on the panel. The superior quality of engineering materials and “Double Butt” contacts with silver bimetal on copper/brass provide stable electrical performance. The high-grade engineering plastics with high tracking index like Nylon, Celcon and glass filled polyamide for the components ensures greater mechanical strength. Advanced manufacturing processes for Cam Switch components under stringent quality conditions ensures durability, reliability and enhanced life and safe operations for a very long time. 02 Cam Operated Rotary Switches Contents Introduction 02 Construction 04 Technical Specifications 05 Isolator Switches 06 Changeover Switches with OFF 07 Changeover Switches without OFF 08 Multistep Switches with OFF 09 Multistep Switches without OFF 10 Instrumentation Selector Switches 11 Motor Control Switches 13 Gang Switches 15 Control Switches 16 Mountings 17 Knobs and Handles 22 Accessories 23 Customised Programme 24 Ordering Code 25 Breaker Control Switches 26 Installation Procedure - Standard Switches 28 DC Switches 29 03 Cam Operated Rotary Switches Cam Operated Rotary Switches Construction Technical Specifications 2.5 Control of DC electromagnets AC-21A Switching of resistive loads, including moderate overloads (frequent switching) DC-23 Switching of motor loads or other highly inductive loads AC-23-A Switching of motor loads or other highly inductive loads (frequent switching) ------ ----- 175 600 15 25 50 50 S200 100 600 10 20 40 50 S125 100 600 10 20 40 50 S100 80 600 10 20 40 50 S80 55 600 3 7.5 7.5 15 30 40 S63 10 460 0.33 0.75 1 1 2 - 15 600 0.33 1 1.5 3 3 5 20 600 0.33 1 1.5 3 3 5 20 600 1.5 3 3 7.5 10 15 30 600 1.5 3 3 7.5 10 15 40 600 2 5 5 10 20 24 S40 S32 RT32 S25 RT25 S20 TP 20 RT 20 S16 TP16 RT16 S10 S6 6 460 0.25 0.50 0.75 1 1 - 05 Note :- AC4 Rating = AC3 rating / 2, Star Delta Rating = 60% of AC3 Rating DC-13 A V HP HP HP HP HP HP Control of AC electromagnetic loads Ampere Rating Operational Voltage HP Rating 1 Phase 120V 240V 3 Phase 120V 240V 480V 600V AC-15 Unit Switching of resistive loads, including moderate overloads AC Rating Code DC-22 CSA/UL Ratings Squirrel Cage otors: starting switching off motors during running Terminal Tightening Torque AC-3 Terminal Cross Section Non-Inductive or slightly Inductive Loads, Resistance Furnaces. Fine strand DC-1 Single / Multiple Non-Inductive or slightly Inductive Loads, Resistance Furnaces Terminal Cross Section AC-1 Rated Duty: 8 Hours, Installation, Operation and Maintenance Condition: Suitable for Environment A (for Industrial Application). Switch life under standard operating conditions: Mechanical 100,000 operations @ 300 cycles / hour, Electrical 10,000 operations at 100 % rated duty for 120 cycles/hour Nm A Metric KA Rated Fuse Short Circuit Current Fuse Size (Type gG/gM) Typical DC Application Short Circuit Capacity Category AC23A "3 Ph , 415 V" Typical AC Application Rated Operational Power DC Duty Rating Category Conformance to standards : European : IEC-60947-1 : 1988 IEC-60947-3 : 1990 IEC-60947-5 : 1992 Canadian : CSA 22.2 No.14-2010 American : UL 508 (2009) 2.5 2.5 2.5 2 2 1.2 1.2 0.8 0.8 0.5 0.5 M10 2XM5 2XM5 2XM5 M5 M5 M4 M4 M3.5 M3.5 M3 M3 50 10 10 35 25 10 6 16 10 2.5 2.5 6 4 1.5 1 2.5 2.5 1 1 2.5 mm2 max 0.7 0.7 1.5 mm2 min 1.5 10 70 50 10 10 35 25 6 4 16 10 2.5 2.5 6 4 1.5 1.5 4 4 1.5 mm2 max 0.7 0.7 1.5 mm2 min 1.5 200 25 25 125 100 25 25 80 63 20 20 40 32 10 10 25 20 5 5 16 10 3 3 6 45 78 64 37 33 57 38 22 18.5 32 26 15 11 19 13 7.5 5.5 10 10 5.5 3 A -- 1.5 KW AC3 "3 Ph , 415 V" -- 55 95 78 45 41 71 57 33 22 38 32 18.5 15 26 19 11 7.5 13 13 7.5 -A 3 2.2 KW -- 225 150 125 100 80 50 40 32 25 20 8 A Rated Uninterrupted Current (Ith) 12 6 200 125 6 6 100 80 6 6 63 40 6 6 32 25 6 6 20 16 6 4 4 A 6 Kv Rated impulse withstand Voltage(Uimp) Rated Operational Current(Ie) AC21/AC1 10 50/60 690 690 50/60 50/60 690 690 50/60 50/60 690 690 50/60 50/60 690 690 50/60 50/60 690 690 440 50/60 V Hz Rated Operational Voltage(Ue) Rated frequency S10 (IP20) AC Duty Rating 04 TP10 S16/TP16/ accessibility accessibility l Available from 6 & 10Amp l Cage clamp (finger protected) S6 to 63Amp convenient TP6 l Available from 16 l ‘Finger Protected Unit l Available from 6 to 20Amp l Finger Protection (IP20) AC Rating Code 400Amp easy IEC/EN Ratings l Available from 6 to l Open terminals for RT53 S63 S40 SL Series Touch Proof & Screwless Termination 440 RT Series Touch Proof & Rear Termination RT40 -150C to 550C 50 to 60Hz 95%, Rh 48 hours S32 TP Series Touch Proof : : : S20/TP20/ S Series Open Version Operating temp Operating frequency Humidity RT32 Double break type AgCdO Glass filled polyamide with high tracking index S25 : : RT25 Contacts Insulation RT20 Series S, TP, RT and SL Cam Switches incorporate two double break silver alloy contacts per stage at 180 degree disposition. The AC Switches are “Quick Make-Slow Break” with in-built latching device feature in cam design. The Cam Switches can be offered for DC applications with additional contacts in series according to the DC switching voltage and with suitable duration and the DC Switches are "Quick Make - Quick Break". 50/60 S125 S100 S80 Contact Assembly RT16 Cam Assembly 50/60 S200 Intertek Cam Operated Rotary Switches Cam Operated Rotary Switches Construction Technical Specifications 2.5 Control of DC electromagnets AC-21A Switching of resistive loads, including moderate overloads (frequent switching) DC-23 Switching of motor loads or other highly inductive loads AC-23-A Switching of motor loads or other highly inductive loads (frequent switching) ------ ----- 175 600 15 25 50 50 S200 100 600 10 20 40 50 S125 100 600 10 20 40 50 S100 80 600 10 20 40 50 S80 55 600 3 7.5 7.5 15 30 40 S63 10 460 0.33 0.75 1 1 2 - 15 600 0.33 1 1.5 3 3 5 20 600 0.33 1 1.5 3 3 5 20 600 1.5 3 3 7.5 10 15 30 600 1.5 3 3 7.5 10 15 40 600 2 5 5 10 20 24 S40 S32 RT32 S25 RT25 S20 TP 20 RT 20 S16 TP16 RT16 S10 S6 6 460 0.25 0.50 0.75 1 1 - 05 Note :- AC4 Rating = AC3 rating / 2, Star Delta Rating = 60% of AC3 Rating DC-13 A V HP HP HP HP HP HP Control of AC electromagnetic loads Ampere Rating Operational Voltage HP Rating 1 Phase 120V 240V 3 Phase 120V 240V 480V 600V AC-15 Unit Switching of resistive loads, including moderate overloads AC Rating Code DC-22 CSA/UL Ratings Squirrel Cage otors: starting switching off motors during running Terminal Tightening Torque AC-3 Terminal Cross Section Non-Inductive or slightly Inductive Loads, Resistance Furnaces. Fine strand DC-1 Single / Multiple Non-Inductive or slightly Inductive Loads, Resistance Furnaces Terminal Cross Section AC-1 Rated Duty: 8 Hours, Installation, Operation and Maintenance Condition: Suitable for Environment A (for Industrial Application). Switch life under standard operating conditions: Mechanical 100,000 operations @ 300 cycles / hour, Electrical 10,000 operations at 100 % rated duty for 120 cycles/hour Nm A Metric KA Rated Fuse Short Circuit Current Fuse Size (Type gG/gM) Typical DC Application Short Circuit Capacity Category AC23A "3 Ph , 415 V" Typical AC Application Rated Operational Power DC Duty Rating Category Conformance to standards : European : IEC-60947-1 : 1988 IEC-60947-3 : 1990 IEC-60947-5 : 1992 Canadian : CSA 22.2 No.14-2010 American : UL 508 (2009) 2.5 2.5 2.5 2 2 1.2 1.2 0.8 0.8 0.5 0.5 M10 2XM5 2XM5 2XM5 M5 M5 M4 M4 M3.5 M3.5 M3 M3 50 10 10 35 25 10 6 16 10 2.5 2.5 6 4 1.5 1 2.5 2.5 1 1 2.5 mm2 max 0.7 0.7 1.5 mm2 min 1.5 10 70 50 10 10 35 25 6 4 16 10 2.5 2.5 6 4 1.5 1.5 4 4 1.5 mm2 max 0.7 0.7 1.5 mm2 min 1.5 200 25 25 125 100 25 25 80 63 20 20 40 32 10 10 25 20 5 5 16 10 3 3 6 45 78 64 37 33 57 38 22 18.5 32 26 15 11 19 13 7.5 5.5 10 10 5.5 3 A -- 1.5 KW AC3 "3 Ph , 415 V" -- 55 95 78 45 41 71 57 33 22 38 32 18.5 15 26 19 11 7.5 13 13 7.5 -A 3 2.2 KW -- 225 150 125 100 80 50 40 32 25 20 8 A Rated Uninterrupted Current (Ith) 12 6 200 125 6 6 100 80 6 6 63 40 6 6 32 25 6 6 20 16 6 4 4 A 6 Kv Rated impulse withstand Voltage(Uimp) Rated Operational Current(Ie) AC21/AC1 10 50/60 690 690 50/60 50/60 690 690 50/60 50/60 690 690 50/60 50/60 690 690 50/60 50/60 690 690 440 50/60 V Hz Rated Operational Voltage(Ue) Rated frequency S10 (IP20) AC Duty Rating 04 TP10 S16/TP16/ accessibility accessibility l Available from 6 & 10Amp l Cage clamp (finger protected) S6 to 63Amp convenient TP6 l Available from 16 l ‘Finger Protected Unit l Available from 6 to 20Amp l Finger Protection (IP20) AC Rating Code 400Amp easy IEC/EN Ratings l Available from 6 to l Open terminals for RT53 S63 S40 SL Series Touch Proof & Screwless Termination 440 RT Series Touch Proof & Rear Termination RT40 -150C to 550C 50 to 60Hz 95%, Rh 48 hours S32 TP Series Touch Proof : : : S20/TP20/ S Series Open Version Operating temp Operating frequency Humidity RT32 Double break type AgCdO Glass filled polyamide with high tracking index S25 : : RT25 Contacts Insulation RT20 Series S, TP, RT and SL Cam Switches incorporate two double break silver alloy contacts per stage at 180 degree disposition. The AC Switches are “Quick Make-Slow Break” with in-built latching device feature in cam design. The Cam Switches can be offered for DC applications with additional contacts in series according to the DC switching voltage and with suitable duration and the DC Switches are "Quick Make - Quick Break". 50/60 S125 S100 S80 Contact Assembly RT16 Cam Assembly 50/60 S200 Intertek Cam Operated Rotary Switches Cam Operated Rotary Switches Isolator Switches Changeover Switches with OFF Isolators are ON-OFF Switches to isolate the power to a particular area of operation. The Isolator Switches are offered in a wide range from 1 Pole to 12 Poles. Isolators with spring return upto 4 Poles are available to energise circuits. Isolators with pre-close contacts are used for safety circuits and for connecting neutral and earth lines. Isolators are generally rated for AC1/AC21 while for motor applications they need to be rated for AC3/AC23A duty. Changeover Switches also called Double Throw Switches are available with OFF and without OFF. These are used to operate two different circuits with different number of inputs and outputs. Changeover Switches without Jumpers (potential free contacts) are used to connect two different circuits from two different sources with two different operating voltages or any other incompatible lines. All contacts by default are “Break Before Make” (BBM) type to avoid overlapping of different circuits. However, for overlapping changeover contacts. “Make Before Break” (MBB) type are offered against specific requirements. Applications: Switching of main/control and instrumentation circuits motor ON-OFF and other special application circuits. Application: Power Supply to Generator Changeover, Auto/Manual Changeover, Standby/Remote Changeover and other special application circuits. Mainly used in Distribution Panels, UPS etc. Connecting Diagram 1 3 5 7 Changeover with Centre OFF 9 11 13 15 17 19 21 23 Without Jumper Connecting Diagram A1 2 4 6 A2 B1 B2 C1 C2 2 3 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 6 7 8 2 4 6 8 10 12 8 10 12 14 16 18 20 22 24 1 1 to 12 pole 4 5 1 1 to 8 Pole Stayput 5 7 3 9 11 1 to 3 Pole Stayput 0 0 ON OFF Script Plate Marking ON OFF 1 2 1 OFF ON 2 ON 0 OFF 60 Degree Description 60 Degree Description Programme Code 90 Degree 90 Degree Complete Rotation Programme Code Programme Code No of Stages 1 Pole 61001 61191 61195 1 2 Pole 61002 61192 61198 1 3 Pole 61003 61199 61197 2 4 Pole 61004 61194 61196 2 5 Pole 61005 - - 3 6 Pole 61006 61906 - 3 7 Pole 61007 - - 4 8 Pole 61008 - - 4 9 Pole 61009 - - 5 10 Pole 61010 - - 5 11 Pole 61011 - - 6 12 Pole 61012 - - 6 1 Pole 2 Pole 3 Pole 4 Pole 5 Pole 6 Pole 7 Pole 8 Pole 1 3 5 7 1 3 5 1 2 3 4 5 6 7 8 1 Pole 2 Pole 3 Pole 4 Pole - 7 1 Spring return to OFF 3 5 OFF 2 4 6 8 10 4 to 5 Pole 2 4 6 S T A R T 4 Pole - 1 Pole Preclose 61194 2 4 Pole - 3 Pole Preclose 61904 1 Pole 2 Pole 3 Pole 7 61361 61362 61363 No of Stages 1 2 3 1 Pole 2 Pole 3 Pole 61364 61365 61369 Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps. 2 4 6 1 8 Spring return to "0" 0 1 2 2 1 to 4 Pole Programme Code No of Stages 1 Pole Spring Return 61351 1 2 2 Pole Spring Return 61352 1 Description 5 Pole - 3 Pole Preclose 61905 3 3 Pole Spring Return 61353 2 61178 2 4 Pole Spring Return 61354 2 Feasible ampere rating for S, TP and RT Series: 16, 20, 25and 32Amps. 60 Degree Stayput without Jumper Description 1 Pole without Jumper 2 Pole without Jumper 3 Pole without Jumper Programme Code No of Stages 45 Degree Spring Return without Jumper Description 61625 1 61626 2 1 Pole without Jumper 2 Pole without Jumper 61627 3 - Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 Amps. 06 900 Spring Return from 1 to “ 0” Description Programme Code 0 3 Pole with Neutral Terminal Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps. 450 Stayput without Jumper 8 No of Stages # Spring return from 1 to "0" 2 450 61194 Programme Code 61151 61152 61153 61154 - 1 Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps. OFF 90 Degree Programme Code 0 2 45 Degree Spring Return to “ 0” Description Programme Code 90 Description 61025 61026 61027 61028 61029 61030 61031 61032 Spring return to "0" 0 1 0 ON Description Spring Return Spring Return Isolators 45 Degree 9 No of Stages Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps. Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 25, 20, 32, 40, 63, 80, 100, 125, 200 and 400Amps. Isolators with Pre-close Contact Programme Code Programme Code 61761 61762 - Feasible ampere rating for S, TP and RT Series : 16, 20, 25, 32Amps. 07 Cam Operated Rotary Switches Cam Operated Rotary Switches Isolator Switches Changeover Switches with OFF Isolators are ON-OFF Switches to isolate the power to a particular area of operation. The Isolator Switches are offered in a wide range from 1 Pole to 12 Poles. Isolators with spring return upto 4 Poles are available to energise circuits. Isolators with pre-close contacts are used for safety circuits and for connecting neutral and earth lines. Isolators are generally rated for AC1/AC21 while for motor applications they need to be rated for AC3/AC23A duty. Changeover Switches also called Double Throw Switches are available with OFF and without OFF. These are used to operate two different circuits with different number of inputs and outputs. Changeover Switches without Jumpers (potential free contacts) are used to connect two different circuits from two different sources with two different operating voltages or any other incompatible lines. All contacts by default are “Break Before Make” (BBM) type to avoid overlapping of different circuits. However, for overlapping changeover contacts. “Make Before Break” (MBB) type are offered against specific requirements. Applications: Switching of main/control and instrumentation circuits motor ON-OFF and other special application circuits. Application: Power Supply to Generator Changeover, Auto/Manual Changeover, Standby/Remote Changeover and other special application circuits. Mainly used in Distribution Panels, UPS etc. Connecting Diagram 1 3 5 7 Changeover with Centre OFF 9 11 13 15 17 19 21 23 Without Jumper Connecting Diagram A1 2 4 6 A2 B1 B2 C1 C2 2 3 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 6 7 8 2 4 6 8 10 12 8 10 12 14 16 18 20 22 24 1 1 to 12 pole 4 5 1 1 to 8 Pole Stayput 5 7 3 9 11 1 to 3 Pole Stayput 0 0 ON OFF Script Plate Marking ON OFF 1 2 1 OFF ON 2 ON 0 OFF 60 Degree Description 60 Degree Description Programme Code 90 Degree 90 Degree Complete Rotation Programme Code Programme Code No of Stages 1 Pole 61001 61191 61195 1 2 Pole 61002 61192 61198 1 3 Pole 61003 61199 61197 2 4 Pole 61004 61194 61196 2 5 Pole 61005 - - 3 6 Pole 61006 61906 - 3 7 Pole 61007 - - 4 8 Pole 61008 - - 4 9 Pole 61009 - - 5 10 Pole 61010 - - 5 11 Pole 61011 - - 6 12 Pole 61012 - - 6 1 Pole 2 Pole 3 Pole 4 Pole 5 Pole 6 Pole 7 Pole 8 Pole 1 3 5 7 1 3 5 1 2 3 4 5 6 7 8 1 Pole 2 Pole 3 Pole 4 Pole - 7 1 Spring return to OFF 3 5 OFF 2 4 6 8 10 4 to 5 Pole 2 4 6 S T A R T 4 Pole - 1 Pole Preclose 61194 2 4 Pole - 3 Pole Preclose 61904 1 Pole 2 Pole 3 Pole 7 61361 61362 61363 No of Stages 1 2 3 1 Pole 2 Pole 3 Pole 61364 61365 61369 Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps. 2 4 6 1 8 Spring return to "0" 0 1 2 2 1 to 4 Pole Programme Code No of Stages 1 Pole Spring Return 61351 1 2 2 Pole Spring Return 61352 1 Description 5 Pole - 3 Pole Preclose 61905 3 3 Pole Spring Return 61353 2 61178 2 4 Pole Spring Return 61354 2 Feasible ampere rating for S, TP and RT Series: 16, 20, 25and 32Amps. 60 Degree Stayput without Jumper Description 1 Pole without Jumper 2 Pole without Jumper 3 Pole without Jumper Programme Code No of Stages 45 Degree Spring Return without Jumper Description 61625 1 61626 2 1 Pole without Jumper 2 Pole without Jumper 61627 3 - Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 Amps. 06 900 Spring Return from 1 to “ 0” Description Programme Code 0 3 Pole with Neutral Terminal Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps. 450 Stayput without Jumper 8 No of Stages # Spring return from 1 to "0" 2 450 61194 Programme Code 61151 61152 61153 61154 - 1 Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps. OFF 90 Degree Programme Code 0 2 45 Degree Spring Return to “ 0” Description Programme Code 90 Description 61025 61026 61027 61028 61029 61030 61031 61032 Spring return to "0" 0 1 0 ON Description Spring Return Spring Return Isolators 45 Degree 9 No of Stages Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps. Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 25, 20, 32, 40, 63, 80, 100, 125, 200 and 400Amps. Isolators with Pre-close Contact Programme Code Programme Code 61761 61762 - Feasible ampere rating for S, TP and RT Series : 16, 20, 25, 32Amps. 07 Cam Operated Rotary Switches Cam Operated Rotary Switches Multistep Switches with OFF Changeover Switches without OFF A1 B1 A2 B2 C1 D1 C2 E1 D2 E2 F1 G1 F2 G2 H1 H2 Multi-Step Switches also called Pole-Way Switches, are available with OFF and without OFF. Multi-Step Switches connect different circuits to a common supply or vice-versa. Multi-Step Switches with 1 Pole, 2 Poles and 3 Poles are popular for 1-Phase, 2-Phase and 3-Phase supply. Without Jumper Connecting Diagram J1 K1 J2 L1 K2 L2 M1 M2 2 4 6 8 10 12 14 16 1 3 5 7 9 11 13 15 Applications: As Tap Changing Switch for Transformer/Stabiliser and other special application circuits. 1 2 4 3 5 6 7 8 10 9 11 12 1 to 12 Pole 1 to 4 Pole Stayput 1 1 1 2 2 2 2 1 90 Degree Complete Rotation Description Programme Code No of Stages 60 Degree Description Programme Code No of Stages 60 Degree Description Programme Code No of Stages 1 Pole 61037 1 5 Pole 61041 5 1 Pole 60177 1 2 Pole 61038 2 6 Pole 61042 6 2 Pole 60178 2 Prog No Description 61059 1 Pole -2 Way 61079 2 Pole-2 Way 1 61099 3 Pole-2 Way 2 61130 4 Pole-2 Way 61060 1 Pole-3 Way 61080 2 Pole-3 Way 61100 3 Pole-3 Way 61131 4 Pole-3 Way 61061 1 Pole-4 Way 3 Pole 4 Pole 61039 61040 3 4 7 Pole 8 Pole 61043 61044 7 8 3 Pole 4 Pole 60179 60180 3 4 61081 2 Pole-4 Way 61101 3 Pole-4 Way - - - 9 Pole 61045 9 - - - 61132 4 Pole-4 Way - - - 10 Pole 11 Pole 12 Pole 61046 61047 61048 10 11 12 - - - 61062 1 Pole-5 Way 61102 3 Pole-5 Way Spring return to "1" 61063 1 Pole-6 Way 1 0 A1 1 61083 3 Way 45 Degree Spring Return Description Programme Code 1 Pole 61371 1 2 Pole 61372 2 3 Pole 61373 3 61064 3 2 A1 B3 A2 2 0 4 A3 3 5 Way 0 60 0 A5 A1 1 4 B1 1 Pole without Jumper 61637 1 1 Pole without Jumper A2 B4 6 Way 6 A6 2 4 2 Pole without Jumper 61638 2 - - 3 Pole without Jumper 61639 3 - - 4 Pole without Jumper 61640 4 - - 45 0 1 8 4 3 A7 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps. 08 Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps. 5 B6 A3 9 8 A6 10 9 8 A9 30 A3 A4 A6 A9 11 Way 0 11 1 2 10 3 9 4 8 7 6 5 0 30 B3 4 7 4 A3 A4 A6 A11 A10 A9 A8 A7 5 A5 1 A8 A7 7 6 5 B2 A1 A2 A10 2 3 4 9 A5 1 A8 A7 0 1 C4 6 A1 A2 30 7 6 5 C3 3 B4 A3 A4 1 A8 A7 2 3 4 C2 A1 A2 0 1 2 B5 1 to 2 Pole 30 2 3 4 8 B1 B7 0 1 1 to 3 Pole A2 3 C5 A1 1 C6 B3 B4 A5 7 6 5 0 1 Pole-11 Way C2 C1 B2 2 B5 A3 A6 2 5 B6 10 Way 61068 3 C3 1 to 3 Pole B1 A2 A4 0 7 1 A5 3 B3 A1 0 45 0 1 Pole-8 Way 1 Pole-10 Way C4 B2 A3 0 61067 C1 3 9 Way 61771 C5 2 A4 6 8 B5 1 2 0 45 Degree Spring return without Jumper Description Programme Sode D3 3 2 No of Stages D2 C3 2 4 4 C2 D4 B3 Spring return to "1" 90 Degree Stayput without Jumper Description Programme Code D1 1 to 4 Pole 2 Pole-7 Way 1 Pole-9 Way 5 C1 B2 C4 8 Way 61066 3 6 2 A2 B4 3 1 Pole-7 Way 1 D1 D2 B1 1 A4 2 3 Pole-6 Way 2 4 C1 D3 C2 A1 1 Stayput without Jumper 2 3 B1 C3 B2 60 0 2 Pole-6 Way 1 3 4 1 to 4 Pole 4 Way Feasible ampere rating for S, TP and RT Series: 16, 20, 25, and 32Amps. 1 D2 1 A4 61065 4 2 1 A3 6 61084 C2 3 B2 2 0 7 Way No of Stages 2 A2 D1 90 OFF 5 61103 C1 B1 1 to 4 Pole 1 2 No. of Stages Connecting Diagram/Terminal Marking 60 0 2 Pole-5 Way Spring Return 1 2 Way 5 61082 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400 Amps. Script Plate Marking/ Operating Quadrant 5 A5 A1 A2 A3 A4 1 A6 6 A5 09 Cam Operated Rotary Switches Cam Operated Rotary Switches Multistep Switches with OFF Changeover Switches without OFF A1 B1 A2 B2 C1 D1 C2 E1 D2 E2 F1 G1 F2 G2 H1 H2 Multi-Step Switches also called Pole-Way Switches, are available with OFF and without OFF. Multi-Step Switches connect different circuits to a common supply or vice-versa. Multi-Step Switches with 1 Pole, 2 Poles and 3 Poles are popular for 1-Phase, 2-Phase and 3-Phase supply. Without Jumper Connecting Diagram J1 K1 J2 L1 K2 L2 M1 M2 2 4 6 8 10 12 14 16 1 3 5 7 9 11 13 15 Applications: As Tap Changing Switch for Transformer/Stabiliser and other special application circuits. 1 2 4 3 5 6 7 8 10 9 11 12 1 to 12 Pole 1 to 4 Pole Stayput 1 1 1 2 2 2 2 1 90 Degree Complete Rotation Description Programme Code No of Stages 60 Degree Description Programme Code No of Stages 60 Degree Description Programme Code No of Stages 1 Pole 61037 1 5 Pole 61041 5 1 Pole 60177 1 2 Pole 61038 2 6 Pole 61042 6 2 Pole 60178 2 Prog No Description 61059 1 Pole -2 Way 61079 2 Pole-2 Way 1 61099 3 Pole-2 Way 2 61130 4 Pole-2 Way 61060 1 Pole-3 Way 61080 2 Pole-3 Way 61100 3 Pole-3 Way 61131 4 Pole-3 Way 61061 1 Pole-4 Way 3 Pole 4 Pole 61039 61040 3 4 7 Pole 8 Pole 61043 61044 7 8 3 Pole 4 Pole 60179 60180 3 4 61081 2 Pole-4 Way 61101 3 Pole-4 Way - - - 9 Pole 61045 9 - - - 61132 4 Pole-4 Way - - - 10 Pole 11 Pole 12 Pole 61046 61047 61048 10 11 12 - - - 61062 1 Pole-5 Way 61102 3 Pole-5 Way Spring return to "1" 61063 1 Pole-6 Way 1 0 A1 1 61083 3 Way 45 Degree Spring Return Description Programme Code 1 Pole 61371 1 2 Pole 61372 2 3 Pole 61373 3 61064 3 2 A1 B3 A2 2 0 4 A3 3 5 Way 0 60 0 A5 A1 1 4 B1 1 Pole without Jumper 61637 1 1 Pole without Jumper A2 B4 6 Way 6 A6 2 4 2 Pole without Jumper 61638 2 - - 3 Pole without Jumper 61639 3 - - 4 Pole without Jumper 61640 4 - - 45 0 1 8 4 3 A7 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps. 08 Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps. 5 B6 A3 9 8 A6 10 9 8 A9 30 A3 A4 A6 A9 11 Way 0 11 1 2 10 3 9 4 8 7 6 5 0 30 B3 4 7 4 A3 A4 A6 A11 A10 A9 A8 A7 5 A5 1 A8 A7 7 6 5 B2 A1 A2 A10 2 3 4 9 A5 1 A8 A7 0 1 C4 6 A1 A2 30 7 6 5 C3 3 B4 A3 A4 1 A8 A7 2 3 4 C2 A1 A2 0 1 2 B5 1 to 2 Pole 30 2 3 4 8 B1 B7 0 1 1 to 3 Pole A2 3 C5 A1 1 C6 B3 B4 A5 7 6 5 0 1 Pole-11 Way C2 C1 B2 2 B5 A3 A6 2 5 B6 10 Way 61068 3 C3 1 to 3 Pole B1 A2 A4 0 7 1 A5 3 B3 A1 0 45 0 1 Pole-8 Way 1 Pole-10 Way C4 B2 A3 0 61067 C1 3 9 Way 61771 C5 2 A4 6 8 B5 1 2 0 45 Degree Spring return without Jumper Description Programme Sode D3 3 2 No of Stages D2 C3 2 4 4 C2 D4 B3 Spring return to "1" 90 Degree Stayput without Jumper Description Programme Code D1 1 to 4 Pole 2 Pole-7 Way 1 Pole-9 Way 5 C1 B2 C4 8 Way 61066 3 6 2 A2 B4 3 1 Pole-7 Way 1 D1 D2 B1 1 A4 2 3 Pole-6 Way 2 4 C1 D3 C2 A1 1 Stayput without Jumper 2 3 B1 C3 B2 60 0 2 Pole-6 Way 1 3 4 1 to 4 Pole 4 Way Feasible ampere rating for S, TP and RT Series: 16, 20, 25, and 32Amps. 1 D2 1 A4 61065 4 2 1 A3 6 61084 C2 3 B2 2 0 7 Way No of Stages 2 A2 D1 90 OFF 5 61103 C1 B1 1 to 4 Pole 1 2 No. of Stages Connecting Diagram/Terminal Marking 60 0 2 Pole-5 Way Spring Return 1 2 Way 5 61082 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400 Amps. Script Plate Marking/ Operating Quadrant 5 A5 A1 A2 A3 A4 1 A6 6 A5 09 Cam Operated Rotary Switches Cam Operated Rotary Switches Instrumentation Selector Switches Multistep Switches without OFF Prog No Description 61049 61069 61089 61120 61124 61126 1 Pole - 3 Way 2 Pole - 3 Way 3 Pole - 3 Way 4 Pole - 3 Way 5 Pole - 3 Way 6 Pole - 3 Way 3 Way 61050 61070 61090 61121 1 Pole - 4 Way 2 Pole - 4 Way 3 Pole - 4 Way 4 Pole - 4 Way 4 Way 61051 61071 61091 61122 1 Pole - 5 Way 2 Pole - 5 Way 3 Pole - 5 Way 4 Pole - 5 Way 5 Way 61052 1 Pole - 6 Way 6 Way 61072 2 Pole - 6 Way Script Plate Marking/ Operating Quadrant 61053 61073 2 Pole - 7 Way 61093 3 Pole - 7 Way 61074 1 Pole - 8 Way E3 F3 2 A2 1 A5 3 4 to 4 Pole C3 600 1 6 4 B2 2 B4 A6 3 A5 A2 B6 A3 B5 1 8 7 2 Pole - 8 Way 3 Pole - 8 Way 0 5 2 3 4 B7 A4 1 Pole - 9 Way 9 1 Pole - 10 Way 1 11 10 9 1 Pole - 11 Way A4 A6 1 Pole - 12 Way B2 2 B3 C2 C3 C5 C1 C2 C3 3 C4 C6 C5 A1 A2 A3 1 A4 A5 A9 A8 A7 A6 300 30 3 4 5 0 30 3 4 5 8 7 6 300 Prog No 3 Way 61650 1 Pole - 4 Way without OFF without Jumper 6 7 11 61313 61670 2 Pole - 4 Way without OFF without Jumper 12 RY 4 61314 3 - Phase Line to Line, Line to Neutral & Without OFF 8 7 9 61317 YB 1 to 2 Pole B 3 YN R Y B N BN BR V1 V V2 600 RY BN YB YN BR R B Y N 3 RN 3 - Phase Line to Line & L1 to N RY R Y B N 450 OFF RN YB V 0 61318 3 - Phase Line to Line 2 Sources 45 OFF RY L1L2 L2L3 YB Source 1 BN B Y V 3 N R Y B L1 L2 L3 L3L1 BR R Y B RN Source 2 4 V1 R Y B N 0 90 OFF 3 - Phase Line to Neutral V BR R L2 L3 L1 V V 60 RY 3 - Phase Line to Line Without OFF B Y V V2 V 2 N R Y B 0 61319 YB V V V 2 BR R Y B Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. Voltmeter and Ammeter Selector Switches 3 5 6 11 12 13 14 3 Y RN Prog No Description 61336 3 Voltages Line - Line & 3 Currents Script Plate Marking/ Operating Quadrant 900 OFF 3 L1 L2 A 4 Voltages & 3 Currents 1 90 1 2 4 3 Voltages Line to Neutral & 3 Currents 900 OFF 3 A A V A B Y A L3 L2 L3 A B Y V A V 2 L1 V A V 6 R L1 L2 1 V L3 L1L2L3 N 61338 B Y R L1 L2 L3 N 3 2 16 15 A 5 V A L2 2 4 A L3 0 61337 No. of Stages Connecting Diagram/Terminal Marking L1 5 2 45 OFF R 10 3 V 0 5 6 4 V YN 2 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125 and 200 Amps. 10 3 - Phase Line to Line & Line to Neutral 8 A12 A1 A2 A11 A3 1 A10 A4 A5 A9 A8 A7 A6 3 V 4 6 2 1 4 R Y B RY R 6 1 BR 4 A1 A2 A11 A3 1 A10 A4 A5 A9 A8 A7 A6 1 3 900 900 YB 61311 2 4 Way 3 - Phase Line to Line No. of Stages Connecting Diagram/Terminal Marking 2 600 1 1 Pole - 3 Way without OFF without Jumper Script Plate Marking/ Operating Quadrant OFF 61312 Multistep Switches without Jumper 61649 Description 5 A1 A2 A3 A10 1 A4 A5 A9 A8 A7 A6 0 Voltmeter Selector Switches 9 C4 C6 C7 1 to 3 Pole B5 3 C8 B4 B6 3 4 5 12 1 2 3 11 4 10 5 9 8 7 6 1 to 3 Pole B5 B7 A3 C2 C4 C7 3 5 8 10 The Instrumentation Selector Switches help to: Measure currents in different circuits with a current transformer a single analog ammeter and a switch l Measure voltages between phases and phase and neutral with one voltmeter and a switch l Measure voltages and currents of a circuit with one voltmeter one ammeter and a single switch l 3 C3 C1 B3 B8 8 7 6 1 2 C5 B2 B1 A2 8 7 6 1 2 10 9 C6 B4 B6 A5 1 2 B2 B3 2 A1 A8 A7 D4 1 to 3 Pole B1 A3 A6 45 1 C4 C1 B4 1 D3 3 A2 A7 D2 4 2 A1 0 45 2 3 4 C2 C3 D5 B1 A5 8 Way D1 3 1 to 4 Pole A1 2 1 5 D2 D3 B3 C5 A4 7 4 C1 A3 B5 A4 7 Way C2 D4 B1 2 4 6 8 D1 3 B2 C4 B3 1 A1 0 C1 90 2 12 Way 61058 A2 B4 A3 1 5 B1 1 3 11 Way 61057 6 D3 C3 A1 A4 2 10 Way 61056 B3 F2 5 4 2 3 5 6 8 9 F1 E2 D2 C2 3 A3 0 4 9 Way 61055 B2 2 90 1 6 61094 A2 1 E1 D1 C1 1 to 6 Pole 6 61054 B1 3 3 Pole - 6 Way 1 Pole - 7 Way 60 2 5 61092 A1 0 1 No. of Stages Connecting Diagram/Terminal Marking V A N 5 R Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. 11 Cam Operated Rotary Switches Cam Operated Rotary Switches Instrumentation Selector Switches Multistep Switches without OFF Prog No Description 61049 61069 61089 61120 61124 61126 1 Pole - 3 Way 2 Pole - 3 Way 3 Pole - 3 Way 4 Pole - 3 Way 5 Pole - 3 Way 6 Pole - 3 Way 3 Way 61050 61070 61090 61121 1 Pole - 4 Way 2 Pole - 4 Way 3 Pole - 4 Way 4 Pole - 4 Way 4 Way 61051 61071 61091 61122 1 Pole - 5 Way 2 Pole - 5 Way 3 Pole - 5 Way 4 Pole - 5 Way 5 Way 61052 1 Pole - 6 Way 6 Way 61072 2 Pole - 6 Way Script Plate Marking/ Operating Quadrant 61053 61073 2 Pole - 7 Way 61093 3 Pole - 7 Way 61074 1 Pole - 8 Way E3 F3 2 A2 1 A5 3 4 to 4 Pole C3 600 1 6 4 B2 2 B4 A6 3 A5 A2 B6 A3 B5 1 8 7 2 Pole - 8 Way 3 Pole - 8 Way 0 5 2 3 4 B7 A4 1 Pole - 9 Way 9 1 Pole - 10 Way 1 11 10 9 1 Pole - 11 Way A4 A6 1 Pole - 12 Way B2 2 B3 C2 C3 C5 C1 C2 C3 3 C4 C6 C5 A1 A2 A3 1 A4 A5 A9 A8 A7 A6 300 30 3 4 5 0 30 3 4 5 8 7 6 300 Prog No 3 Way 61650 1 Pole - 4 Way without OFF without Jumper 6 7 11 61313 61670 2 Pole - 4 Way without OFF without Jumper 12 RY 4 61314 3 - Phase Line to Line, Line to Neutral & Without OFF 8 7 9 61317 YB 1 to 2 Pole B 3 YN R Y B N BN BR V1 V V2 600 RY BN YB YN BR R B Y N 3 RN 3 - Phase Line to Line & L1 to N RY R Y B N 450 OFF RN YB V 0 61318 3 - Phase Line to Line 2 Sources 45 OFF RY L1L2 L2L3 YB Source 1 BN B Y V 3 N R Y B L1 L2 L3 L3L1 BR R Y B RN Source 2 4 V1 R Y B N 0 90 OFF 3 - Phase Line to Neutral V BR R L2 L3 L1 V V 60 RY 3 - Phase Line to Line Without OFF B Y V V2 V 2 N R Y B 0 61319 YB V V V 2 BR R Y B Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. Voltmeter and Ammeter Selector Switches 3 5 6 11 12 13 14 3 Y RN Prog No Description 61336 3 Voltages Line - Line & 3 Currents Script Plate Marking/ Operating Quadrant 900 OFF 3 L1 L2 A 4 Voltages & 3 Currents 1 90 1 2 4 3 Voltages Line to Neutral & 3 Currents 900 OFF 3 A A V A B Y A L3 L2 L3 A B Y V A V 2 L1 V A V 6 R L1 L2 1 V L3 L1L2L3 N 61338 B Y R L1 L2 L3 N 3 2 16 15 A 5 V A L2 2 4 A L3 0 61337 No. of Stages Connecting Diagram/Terminal Marking L1 5 2 45 OFF R 10 3 V 0 5 6 4 V YN 2 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125 and 200 Amps. 10 3 - Phase Line to Line & Line to Neutral 8 A12 A1 A2 A11 A3 1 A10 A4 A5 A9 A8 A7 A6 3 V 4 6 2 1 4 R Y B RY R 6 1 BR 4 A1 A2 A11 A3 1 A10 A4 A5 A9 A8 A7 A6 1 3 900 900 YB 61311 2 4 Way 3 - Phase Line to Line No. of Stages Connecting Diagram/Terminal Marking 2 600 1 1 Pole - 3 Way without OFF without Jumper Script Plate Marking/ Operating Quadrant OFF 61312 Multistep Switches without Jumper 61649 Description 5 A1 A2 A3 A10 1 A4 A5 A9 A8 A7 A6 0 Voltmeter Selector Switches 9 C4 C6 C7 1 to 3 Pole B5 3 C8 B4 B6 3 4 5 12 1 2 3 11 4 10 5 9 8 7 6 1 to 3 Pole B5 B7 A3 C2 C4 C7 3 5 8 10 The Instrumentation Selector Switches help to: Measure currents in different circuits with a current transformer a single analog ammeter and a switch l Measure voltages between phases and phase and neutral with one voltmeter and a switch l Measure voltages and currents of a circuit with one voltmeter one ammeter and a single switch l 3 C3 C1 B3 B8 8 7 6 1 2 C5 B2 B1 A2 8 7 6 1 2 10 9 C6 B4 B6 A5 1 2 B2 B3 2 A1 A8 A7 D4 1 to 3 Pole B1 A3 A6 45 1 C4 C1 B4 1 D3 3 A2 A7 D2 4 2 A1 0 45 2 3 4 C2 C3 D5 B1 A5 8 Way D1 3 1 to 4 Pole A1 2 1 5 D2 D3 B3 C5 A4 7 4 C1 A3 B5 A4 7 Way C2 D4 B1 2 4 6 8 D1 3 B2 C4 B3 1 A1 0 C1 90 2 12 Way 61058 A2 B4 A3 1 5 B1 1 3 11 Way 61057 6 D3 C3 A1 A4 2 10 Way 61056 B3 F2 5 4 2 3 5 6 8 9 F1 E2 D2 C2 3 A3 0 4 9 Way 61055 B2 2 90 1 6 61094 A2 1 E1 D1 C1 1 to 6 Pole 6 61054 B1 3 3 Pole - 6 Way 1 Pole - 7 Way 60 2 5 61092 A1 0 1 No. of Stages Connecting Diagram/Terminal Marking V A N 5 R Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. 11 Cam Operated Rotary Switches Cam Operated Rotary Switches Ammeter Selector Switches Prog No Description 61325 1 Pole 3 Transformer with OFF Motor Control Switches Script Plate Marking/ Operating Quadrant B Y R Y A 1 Pole 1 Transformer R Y Motor Reversing Switches 1 Pole 2 Transformer 3 0 90 61384 61326 61327 1 Pole 4 Transformer with OFF 2 Pole 2 Transformer with OFF A A 1 Y 3 A L3 L2 3 Pole 3 Transformer with OFF 61330 4 Pole 4 Transformer without OFF Direct ammeter Selector without Current Transformer (16 to 63Amps) Spring return to "1" 0 45 0 1 U VW 4 A2 Prog No Description 61200 OFF Star - Delta Script Plate Marking/ Operating Quadrant B R1 Y2 B1 Y 600 0 5 A1 A A2 Spring Return from Star to OFF Y U1 V1 W1 450 R2 Y1 Y2 B1 B2 N1 R A1 Y A B1 B2 R1 Y1 R2 Y2 A2 Standard Y 0 60 Y U1 V1 W1 5 L2 61239 0 90 3 L1 L2 L3 ON 1 5 7 2 U2 V2 W2 M 3~ 2 PF Star Delta with Sequence Locking & LMD Contractor Y 4 1 3 2 C 600 C 0 3 e e A1 B1 C1 8 6 M3 ~ ON Y- 7 6 L1 L2 L3 90 OFF C PF 1 90 OFF 1 2 A2 B2C2 5 6 7 2 2 1 L1 L2 L3 14 L1 L2 L3 9 2 13 17 15 1 6 3 8 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. 5 L3 L1 L2 L3 61240 12 U2 V2 W2 L2 L3 0 L1 0 Two Wattmeter Method L3 M 3~ L1 61203 N2 L1 L2 L3 900 OFF L2 4 6 3 OFF 61201 0 OFF 73071 4 L1 L2 L3 A2 B2 Y B N 2 ON No. of Stages R 900 1 R2 Y1 0 Two Current Transformer 3 M 3~ Connecting Diagram/Terminal Marking L1 A Power Factor Meter and Wattmeter Switches 73079 3 3 Y2 A1 B One Current Transformer One Voltage Transformer M 3~ 2 Motor Switches/Star Delta Switches Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. 73078 L1 L2 L3 L1 L2 L3 2 5 90 Y B 3 Pole Spring Return UVW R R1 71000 A R 4 61253 M 2~ L1 L2 0 Y R 3 Pole 90 OFF 0 61329 61211 3 R2 Y 3 Pole 3 Transformer without OFF A A A1 R1 B L2 L1 Y1 61328 UV R Y 2 L1 2 2 R 900 L1 L2 L3 0 60 0 Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32Amps and above. A L4 0 A A A 3 1 B Y L1 L2 L3 L4 2 2 Pole No. of Stages Connecting Diagram/Terminal Marking L1 L2 L3 A 4 A B 900 61210 Script Plate Marking/ Operating Quadrant R Y 1 A R 0 Description 1 1 90 Prog No R Y 2 1 R 2 1 Pole 3 Transformer without OFF A A OFF A 61331 3 B A OFF A A R 900 ON 61321 A B Motor Control Switches directly operate the motor with AC3 or AC4 duty rating. They are typically used for “Forward-Reverse”, “Star-Delta” and “Two Speed Forward-Reverse”. Motor Control Switches are also designed to operate with a contactor having built-in tripping feature in the event of power failure and overload. R 900 OFF No. of Stages Connecting Diagram/Terminal Marking For use with Contractors Y 2 900 0 W1 V1 U1 4 5 M 3~ 18 4 U2 V2 W2 Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32. 40 and 63Amps. 13 Cam Operated Rotary Switches Cam Operated Rotary Switches Ammeter Selector Switches Prog No Description 61325 1 Pole 3 Transformer with OFF Motor Control Switches Script Plate Marking/ Operating Quadrant B Y R Y A 1 Pole 1 Transformer R Y Motor Reversing Switches 1 Pole 2 Transformer 3 0 90 61384 61326 61327 1 Pole 4 Transformer with OFF 2 Pole 2 Transformer with OFF A A 1 Y 3 A L3 L2 3 Pole 3 Transformer with OFF 61330 4 Pole 4 Transformer without OFF Direct ammeter Selector without Current Transformer (16 to 63Amps) Spring return to "1" 0 45 0 1 U VW 4 A2 Prog No Description 61200 OFF Star - Delta Script Plate Marking/ Operating Quadrant B R1 Y2 B1 Y 600 0 5 A1 A A2 Spring Return from Star to OFF Y U1 V1 W1 450 R2 Y1 Y2 B1 B2 N1 R A1 Y A B1 B2 R1 Y1 R2 Y2 A2 Standard Y 0 60 Y U1 V1 W1 5 L2 61239 0 90 3 L1 L2 L3 ON 1 5 7 2 U2 V2 W2 M 3~ 2 PF Star Delta with Sequence Locking & LMD Contractor Y 4 1 3 2 C 600 C 0 3 e e A1 B1 C1 8 6 M3 ~ ON Y- 7 6 L1 L2 L3 90 OFF C PF 1 90 OFF 1 2 A2 B2C2 5 6 7 2 2 1 L1 L2 L3 14 L1 L2 L3 9 2 13 17 15 1 6 3 8 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. 5 L3 L1 L2 L3 61240 12 U2 V2 W2 L2 L3 0 L1 0 Two Wattmeter Method L3 M 3~ L1 61203 N2 L1 L2 L3 900 OFF L2 4 6 3 OFF 61201 0 OFF 73071 4 L1 L2 L3 A2 B2 Y B N 2 ON No. of Stages R 900 1 R2 Y1 0 Two Current Transformer 3 M 3~ Connecting Diagram/Terminal Marking L1 A Power Factor Meter and Wattmeter Switches 73079 3 3 Y2 A1 B One Current Transformer One Voltage Transformer M 3~ 2 Motor Switches/Star Delta Switches Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. 73078 L1 L2 L3 L1 L2 L3 2 5 90 Y B 3 Pole Spring Return UVW R R1 71000 A R 4 61253 M 2~ L1 L2 0 Y R 3 Pole 90 OFF 0 61329 61211 3 R2 Y 3 Pole 3 Transformer without OFF A A A1 R1 B L2 L1 Y1 61328 UV R Y 2 L1 2 2 R 900 L1 L2 L3 0 60 0 Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32Amps and above. A L4 0 A A A 3 1 B Y L1 L2 L3 L4 2 2 Pole No. of Stages Connecting Diagram/Terminal Marking L1 L2 L3 A 4 A B 900 61210 Script Plate Marking/ Operating Quadrant R Y 1 A R 0 Description 1 1 90 Prog No R Y 2 1 R 2 1 Pole 3 Transformer without OFF A A OFF A 61331 3 B A OFF A A R 900 ON 61321 A B Motor Control Switches directly operate the motor with AC3 or AC4 duty rating. They are typically used for “Forward-Reverse”, “Star-Delta” and “Two Speed Forward-Reverse”. Motor Control Switches are also designed to operate with a contactor having built-in tripping feature in the event of power failure and overload. R 900 OFF No. of Stages Connecting Diagram/Terminal Marking For use with Contractors Y 2 900 0 W1 V1 U1 4 5 M 3~ 18 4 U2 V2 W2 Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32. 40 and 63Amps. 13 Cam Operated Rotary Switches Cam Operated Rotary Switches Gang Switches Motor Switches/Multi Speed Switches Prog No Description Script Plate Marking/ Operating Quadrant 61212 2 Speed in one Direction Single Winding 2 Speed with Centre OFF Single Winding 1 2 L1 61215 2 Speed Single Winding for use (with Contractor) L2 2 U1 V1 W1 M 3~ U2 V2 W2 U1 V1 W1 M 3~ U2 V2 W2 No. of Stages The Gang Switches increase capacity of circuits by ganging in serial or parallel operations for different circuit capacity. Serialing enhances power of battery supply and paralleling the power of resistor. 4 Applications: In railway coaches for controlling the Alternator and Battery supply. Also in telecom panels and special application circuits. L3 L1 L2 L3 600 0 61213 L1 L2 L3 600 1 0 Connecting Diagram/Terminal Marking 61219 2 Speed Single Winding Forwarding/ Reversing 2 Speed 2 Separate Windings 61243 L1 L2 L3 600 1 L2 L3 2 Gang with OFF 1 Pole 17 Connecting Diagram/Terminal Marking U1 V1 W1 M 3~ U2 V2 W2 L1 L2 L3 600 1 1 2 2 61117 U1 V1 W1 L1 600 1 2 0 600 OFF 1 3 L1 L2 L3 3 L2 L1 L2 L3 0 90 1 1U1 1V1 1W1 L1 L3 L2 L1 N 2 Pole B1 B2 A1 B1 C1 A2 B2 C2 L1 L2 L3 3 A B L1 L2 L3 3 Gang with OFF 1 Pole 3 Gang with OFF 2 Pole 3 L1 L2 L3 900 1 2 A1 A2 A3 A L1 L2 L3 2 3 Gang with OFF 3 Pole B 3 C 3 Pole B1 B2 B3 A1 A2 L1 Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40 and 63Amps. C 1 Pole 6 61112 B L1 OFF A N B 5 1 Pole L1 Motor Switches - Start and Run Switches Prog No Description 61113 Script Plate Marking/ Operating Quadrant Spring return from Start to "0" 61208 Split - Phase Start No. of Stages Connecting Diagram/Terminal Marking L1 1 START 61115 U1 N U2 0 M K1 2 2 Gang, Series with OFF 1 Pole 2 Gang, Series with OFF 2 Pole A1 A2 L1 N 2 GANG L1 N 0 90 OFF 3 1 1 A B 2 Pole B1 B2 A1 B1 C1 A2 B2 C2 L1 L2 L3 2 A 2 B L1 L2 L3 L1 Spring return from Start 61209 Split - Phase Start Reversing 61114 L1 U1 N 2 U2 M Z1 Z2 3 2 Gang, Series with OFF 3 Pole Split - Phase Start Reversing Switching 60 0 1 2 N B 2 L1 3 L1 1 L2 Feasible ampere rating: 16, 20, 25 and 32Amps and for Sprint Return Switches and for Stay put 16Amps and above. 3 Pole 2 Gang Series Parallel 1 L1 1 L2 1 L1 14 3 A L1 L2 L3 0 61270 A1 B1 C1 A2 B2 C2 L1 L2 L3 START START L1 3 Pole N 0 1 3 Pole A1 A2 A3 A N 3 GANG 61118 1U21V21W2 2 A B 2 2 Gang with OFF 3 Pole 6 2U1 2V1 2W1 M 3~ A1 A2 0 60 1 L1 2U1 2V1 2W1 M 3~ 0 2 Gang with OFF 2 Pole 3 1U21V21W2 L3 L1 L2 L3 2 1 1 Pole L1 N 61110 1U1 1V1 1W1 L2 U2 V2 W2 M 3~ L3 2 OFF B L1 6 61111 U1 V1 W1 L1 U2 V2 W2 M 3~ L3 L2 2 GANG 5 L1 L2 L3 0 No. of Stages A1 A2 A N 18 2 0 3 Speed 2 Windings (O-A-B-A) 3 Speed 2 Windings (O-A-B-B) 61109 Script Plate Marking/ Operating Quadrant L1 L1 L1 61226 Description 4 20 61217 Prog No M 61116 2 L2 3 L2 3 2 Gang, Series Parallel with OFF 2 Pole 900 OFF 3 L1 N A1 B1 A2 A 1 2 L1 N 2 B 3 Pole Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40 and 63Amps. 15 Cam Operated Rotary Switches Cam Operated Rotary Switches Gang Switches Motor Switches/Multi Speed Switches Prog No Description Script Plate Marking/ Operating Quadrant 61212 2 Speed in one Direction Single Winding 2 Speed with Centre OFF Single Winding 1 2 L1 61215 2 Speed Single Winding for use (with Contractor) L2 2 U1 V1 W1 M 3~ U2 V2 W2 U1 V1 W1 M 3~ U2 V2 W2 No. of Stages The Gang Switches increase capacity of circuits by ganging in serial or parallel operations for different circuit capacity. Serialing enhances power of battery supply and paralleling the power of resistor. 4 Applications: In railway coaches for controlling the Alternator and Battery supply. Also in telecom panels and special application circuits. L3 L1 L2 L3 600 0 61213 L1 L2 L3 600 1 0 Connecting Diagram/Terminal Marking 61219 2 Speed Single Winding Forwarding/ Reversing 2 Speed 2 Separate Windings 61243 L1 L2 L3 600 1 L2 L3 2 Gang with OFF 1 Pole 17 Connecting Diagram/Terminal Marking U1 V1 W1 M 3~ U2 V2 W2 L1 L2 L3 600 1 1 2 2 61117 U1 V1 W1 L1 600 1 2 0 600 OFF 1 3 L1 L2 L3 3 L2 L1 L2 L3 0 90 1 1U1 1V1 1W1 L1 L3 L2 L1 N 2 Pole B1 B2 A1 B1 C1 A2 B2 C2 L1 L2 L3 3 A B L1 L2 L3 3 Gang with OFF 1 Pole 3 Gang with OFF 2 Pole 3 L1 L2 L3 900 1 2 A1 A2 A3 A L1 L2 L3 2 3 Gang with OFF 3 Pole B 3 C 3 Pole B1 B2 B3 A1 A2 L1 Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40 and 63Amps. C 1 Pole 6 61112 B L1 OFF A N B 5 1 Pole L1 Motor Switches - Start and Run Switches Prog No Description 61113 Script Plate Marking/ Operating Quadrant Spring return from Start to "0" 61208 Split - Phase Start No. of Stages Connecting Diagram/Terminal Marking L1 1 START 61115 U1 N U2 0 M K1 2 2 Gang, Series with OFF 1 Pole 2 Gang, Series with OFF 2 Pole A1 A2 L1 N 2 GANG L1 N 0 90 OFF 3 1 1 A B 2 Pole B1 B2 A1 B1 C1 A2 B2 C2 L1 L2 L3 2 A 2 B L1 L2 L3 L1 Spring return from Start 61209 Split - Phase Start Reversing 61114 L1 U1 N 2 U2 M Z1 Z2 3 2 Gang, Series with OFF 3 Pole Split - Phase Start Reversing Switching 60 0 1 2 N B 2 L1 3 L1 1 L2 Feasible ampere rating: 16, 20, 25 and 32Amps and for Sprint Return Switches and for Stay put 16Amps and above. 3 Pole 2 Gang Series Parallel 1 L1 1 L2 1 L1 14 3 A L1 L2 L3 0 61270 A1 B1 C1 A2 B2 C2 L1 L2 L3 START START L1 3 Pole N 0 1 3 Pole A1 A2 A3 A N 3 GANG 61118 1U21V21W2 2 A B 2 2 Gang with OFF 3 Pole 6 2U1 2V1 2W1 M 3~ A1 A2 0 60 1 L1 2U1 2V1 2W1 M 3~ 0 2 Gang with OFF 2 Pole 3 1U21V21W2 L3 L1 L2 L3 2 1 1 Pole L1 N 61110 1U1 1V1 1W1 L2 U2 V2 W2 M 3~ L3 2 OFF B L1 6 61111 U1 V1 W1 L1 U2 V2 W2 M 3~ L3 L2 2 GANG 5 L1 L2 L3 0 No. of Stages A1 A2 A N 18 2 0 3 Speed 2 Windings (O-A-B-A) 3 Speed 2 Windings (O-A-B-B) 61109 Script Plate Marking/ Operating Quadrant L1 L1 L1 61226 Description 4 20 61217 Prog No M 61116 2 L2 3 L2 3 2 Gang, Series Parallel with OFF 2 Pole 900 OFF 3 L1 N A1 B1 A2 A 1 2 L1 N 2 B 3 Pole Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40 and 63Amps. 15 Cam Operated Rotary Switches Cam Operated Rotary Switches Control Switches Mountings Feasibility Control Switches are used to energise contactors for controlling motor operations. Most of the Switches are “Spring Return” type for latching of the circuit with NO contact and facilitate tripping by the tripping device. Applications: Control Switches offer unique alternative to multiple “Push Button Stations”, when one Switch controls instead of many Push Buttons. Control Switch with many positions are offered for a suitable combination. Prog No. 61300 Description 1 Pole STOP START with Spring Return Script Plate Marking/ Operating Quadrant Spring return 61301 0 STOP 4 2 L1 N 0,1 START Without Jumper 61307 STOP - START SWITCH with Spring Return to Run for a2 Units 4 Spring return from START to "1" 1 L1 N START 0,1 START 0 Without Jumper 61366 Contactor Control with Spring Return to OFF 4 L1 N 0 0 1 1 2 2 START 3 START 1 5 2 4 L1 N1 L2 N2 Spring return to "0" 1 2 0 1 START 2 15 6 2 6 2 7 3 8 4 2 + _ P 61271 1 3 1 Spring return from START START START 61707 2 3 1 2 2 61701 1 A2 START A1 START 2 Pole STOP START with Spring Return 1 Pole STOP START with Spring Return from Start to Run No. Of Stages L1 N STOP 61388 Connecting Diagram/Terminal Marking Motor Voltage Control Switch N 1 5 L S 4 2 6 M L S Mounting Code Feasibility Description 6/10A 16/20A 25/32A 40/63A 80/100/ 200/ 125A 400A B03 Front Mounting, Standard Mounting plate B13 Front Mounting with next size plate B00 Front Mounting 48X48 plate for 25/32A and 64x64 plate for 40/63A B19 Single Hole Mounting 32x32 plate for 6/10A only 48x48 Plate for 16-32Amps B14 Single Hole Mounting 48x48 plate for 6/10A B33 Front Mounting with Round padlock for 2 Position (for Isolators) B30 Front Mounting with Rectangular Padlock 2 Position (for Isolators) B63 Key Lockable type (Handle/Knob) B90 Centre Key Lock (Pistol grip Handle in black colour only) B02 Rear/(Back/Base) Mounting B21 Din Rail Mounting on 35mm Rail 6-32Amps B32 Rear/Base Mounting, Door Interlock + Rectangular Padlock (B30+B42) B34 Rear/Base Mounting, Door Interlock + Round Padlock (B33+B42) B41 Rear Mounting with Clutch Mechanism on Door (Door Open in all position without Interlock) B42 Rear Mounting with Interlock Mechanism on Door F47 Door Clutch, Mounting Plate at front 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 B17 ABS Enclosure Max stages B31 ABS Enclosure with Round Padlock (B33+B17) Max stages upto 4 upto 3 upto 5 upto 5 M17 Metal Enclosure Max stages upto 4 upto 4 upto 3 A17 Aluminium Enclosure Max stages upto 4 upto 3 upto 2 B40 Single Hole Mounting with Padlock 48 x 48 Plate For 16-32A B43 Single Hole Mounting with Centre Key 48 x 48 Plate for 16-32A B45 Single Hole Mounting with Round Ring with Knob 16A-32A upto 3 upto 2 upto 2 3 3 3 3 3 3 3 Mountings B03 SERIES SPLIT FIELD Front Mountings S 3 to 5 2 ØB3 Drilling plan Panel gap ØB2 D SQF Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40 and 63Amps. A L SQ B1 Length L = No of Stages of Prog x S + W 6/10 Amps by default B13 mounting 48x48mm only IP55 protection from front Quote B13 for next bigger size front plate Features: n Standard 4 Hole front panel mounting n Knob/Handle operatable n Suitable for all switching angles and Spring Return Switches n Front assembly in 4 different colors, Yellow/Red, Grey/Black, Black/Black and aluminum finish 16 A B1 B2 B3 D F S W Max S6/S10/TP6/TP10/SL6/SL10 (48x48mm)-B13 Type 28 36 12 4.5 38 48 9.5 18.5 12 S16/TP16/RT16/TP20/RT20 28 36 12 4.5 58 48 12 26 21 S25/S32/RT25/RT32 35 48 12 5.5 64 64 15 27 18 S40/S63/RT40/RT63 44 68 15 5.5 95 88 21 33 12 S80/S100/S125 44 68 15 5.5 118 88 26 40 10 S200 44 68 15 5.5 99 88 32 40 10 S400 44 68 15 5.5 99 88 64 40 4 17 Cam Operated Rotary Switches Cam Operated Rotary Switches Control Switches Mountings Feasibility Control Switches are used to energise contactors for controlling motor operations. Most of the Switches are “Spring Return” type for latching of the circuit with NO contact and facilitate tripping by the tripping device. Applications: Control Switches offer unique alternative to multiple “Push Button Stations”, when one Switch controls instead of many Push Buttons. Control Switch with many positions are offered for a suitable combination. Prog No. 61300 Description 1 Pole STOP START with Spring Return Script Plate Marking/ Operating Quadrant Spring return 61301 0 STOP 4 2 L1 N 0,1 START Without Jumper 61307 STOP - START SWITCH with Spring Return to Run for a2 Units 4 Spring return from START to "1" 1 L1 N START 0,1 START 0 Without Jumper 61366 Contactor Control with Spring Return to OFF 4 L1 N 0 0 1 1 2 2 START 3 START 1 5 2 4 L1 N1 L2 N2 Spring return to "0" 1 2 0 1 START 2 15 6 2 6 2 7 3 8 4 2 + _ P 61271 1 3 1 Spring return from START START START 61707 2 3 1 2 2 61701 1 A2 START A1 START 2 Pole STOP START with Spring Return 1 Pole STOP START with Spring Return from Start to Run No. Of Stages L1 N STOP 61388 Connecting Diagram/Terminal Marking Motor Voltage Control Switch N 1 5 L S 4 2 6 M L S Mounting Code Feasibility Description 6/10A 16/20A 25/32A 40/63A 80/100/ 200/ 125A 400A B03 Front Mounting, Standard Mounting plate B13 Front Mounting with next size plate B00 Front Mounting 48X48 plate for 25/32A and 64x64 plate for 40/63A B19 Single Hole Mounting 32x32 plate for 6/10A only 48x48 Plate for 16-32Amps B14 Single Hole Mounting 48x48 plate for 6/10A B33 Front Mounting with Round padlock for 2 Position (for Isolators) B30 Front Mounting with Rectangular Padlock 2 Position (for Isolators) B63 Key Lockable type (Handle/Knob) B90 Centre Key Lock (Pistol grip Handle in black colour only) B02 Rear/(Back/Base) Mounting B21 Din Rail Mounting on 35mm Rail 6-32Amps B32 Rear/Base Mounting, Door Interlock + Rectangular Padlock (B30+B42) B34 Rear/Base Mounting, Door Interlock + Round Padlock (B33+B42) B41 Rear Mounting with Clutch Mechanism on Door (Door Open in all position without Interlock) B42 Rear Mounting with Interlock Mechanism on Door F47 Door Clutch, Mounting Plate at front 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 B17 ABS Enclosure Max stages B31 ABS Enclosure with Round Padlock (B33+B17) Max stages upto 4 upto 3 upto 5 upto 5 M17 Metal Enclosure Max stages upto 4 upto 4 upto 3 A17 Aluminium Enclosure Max stages upto 4 upto 3 upto 2 B40 Single Hole Mounting with Padlock 48 x 48 Plate For 16-32A B43 Single Hole Mounting with Centre Key 48 x 48 Plate for 16-32A B45 Single Hole Mounting with Round Ring with Knob 16A-32A upto 3 upto 2 upto 2 3 3 3 3 3 3 3 Mountings B03 SERIES SPLIT FIELD Front Mountings S 3 to 5 2 ØB3 Drilling plan Panel gap ØB2 D SQF Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40 and 63Amps. A L SQ B1 Length L = No of Stages of Prog x S + W 6/10 Amps by default B13 mounting 48x48mm only IP55 protection from front Quote B13 for next bigger size front plate Features: n Standard 4 Hole front panel mounting n Knob/Handle operatable n Suitable for all switching angles and Spring Return Switches n Front assembly in 4 different colors, Yellow/Red, Grey/Black, Black/Black and aluminum finish 16 A B1 B2 B3 D F S W Max S6/S10/TP6/TP10/SL6/SL10 (48x48mm)-B13 Type 28 36 12 4.5 38 48 9.5 18.5 12 S16/TP16/RT16/TP20/RT20 28 36 12 4.5 58 48 12 26 21 S25/S32/RT25/RT32 35 48 12 5.5 64 64 15 27 18 S40/S63/RT40/RT63 44 68 15 5.5 95 88 21 33 12 S80/S100/S125 44 68 15 5.5 118 88 26 40 10 S200 44 68 15 5.5 99 88 32 40 10 S400 44 68 15 5.5 99 88 64 40 4 17 Cam Operated Rotary Switches Cam Operated Rotary Switches Single Hole Mounting (22.5mm cutout) Key Lockabale B63 Locking lever B19/B14 3 3 Max. Panel gap S Drilling plan S Ø5.5 A 3 to 5 Panel gap 48 13 48 B5 F D F D B2 L IP65 protection from front Features: n Single hole mounting with std dia 22.5 mm n Eliminates the need for screws/hardware for Quick-Fit Single Hole panel fixing n Easy termination n Available upto 32Amp B33 H A 23 Drilling plan Length L = No of Stages x S + W L Quote B14 for next bigger size front plate (available for 6/10Amps. only) Type Code A D F S S6/S10/TP6/TP10 B19 25 38 32 9.5 13.5 28.5 10 B14 27 38 48 9.5 13.5 28.5 10 S16/TP16/RT16/TP20/RT20 B19 S25/S32/RT25/RT32 32 B19 58 32 48 64 12 48 15 H IP40 protection from front W 13 36 13 37 Max 8 6 Pad Lockable Mountings S Drilling plan ØB3 3 to 5 Panel gap ON ØB2 B4 Length L = No of Stages x S + W Features: n Knob/Handle operatable Switch With key lockable assembly prevents switching by unauthorised personnel n Key lock/Key removable only in OFF position by default, key lockable and removable in any other position to be specified n Lock assembly can also be provided on any side n Common key for all Switches Features : Type B2 B4 B5 D F S W 35 13 23 43.5 58 64 12 45 Max 21 S25/S32/RT25/RT32 35 13 23 43.5 64 64 15 45 15 S40/S63/RT40/RT63 44 13 23 43.5 95 64 21 47 10 Enclosure D B17 A S16/TP16/RT16/TP20/RT20 LR/HR Model Ø5 .5 .5 L H J G Length L = No of Stages x S + W Ø5 .5 Ø5 SQ B1 F A L B F-48mm with B1-36mm also available on request for 16,25,32Amps Type B1 B2 B3 D F S W 44 36 12 4.5 58 65 12 26 Max 6 S25/S32/RT25/RT32 44 36 12 4.5 64 65 15 27 6 S40/S63/RT40/RT63 48 68 15 5.5 95 95 21 33 6 S80/S100/S125 48 68 15 5.5 118 95 26 40 6 E DrillingI plan 48 68 15 5.5 99 95 32 40 6 IP55 48 68 15 5.5 99 95 64 40 3 Features: n Switch mounted in ABS Enclosure n Provides protection from dust and hazardous material with regular Front Plate and Knob n Suitable for all switching angles n Knob/Handle operatable n IP65 can be given on request 3 to 5 Panel gap H Drilling plan F1 Ø5.5 B2 0 D E A Drilling plan F2 D 1 B Ø4.5 S200 S A SM, M S400 B30 D L A S16/TP16/RT16/TP20/RT20 SQ F Features: hole round padlockable mounting n Secure with max. 3 padlocks in OFF position prevents switching ON by unauthorised personnel n Suitable for switches only with 900 switching angle n Four G IP55 protection from front Quote B31 (B17 Enclosure and B33 Round Padlock) only for Isolater ON/OFF Switches B1 L A Features: hole rectangular padlockable mounting n Secure with max four padlocks in OFF position n Prevents switching only n Unauthorised personnel n Suitable for switches with 90switching angle n Four n Available 18 Type S16/TP16/RT16/TP20/RT20 Box Type A L B D E G Stages S6/S10/TP6/TP10 SM 28 125 100 72 80 115 4 S16/TP16/RT16 SM 28 125 100 72 80 115 3 S16/TP16/RT16 F3 Length L = No of Stages x S + W IP55 protection from front Type S25/S32/RT25/RT32 M 28 175 125 90 105 155 4 SM 35 125 100 72 80 115 2 A B1 B2 D F1 F2 F3 H S W Max S25/S32/RT25/RT32 M 35 175 125 90 105 155 4 35 48 58 76 104 12 23 12 26 S40/S63/RT40/RT63 M 44 175 125 90 105 155 2 I J - - 12 6 S25/S32/RT25/RT32 35 48 12 64 76 104 12 23 15 27 6 S40/S63/RT40/RT63 44 68 15 95 99 128 15 25 21 33 6 S80/S100/S125 44 68 15 118 99 128 15 25 26 40 6 S200 44 68 15 99 99 128 15 25 32 40 6 S400 44 68 15 99 99 128 15 25 64 40 3 Type Code A L B D E G H S25/S32/RT25/RT32 LR 38 130 115 161 87 102 100 S40/S63/RT40/RT63 HR 46 180 155 220 120 100 - 122 147 Stages 5 5 in Yellow/Red only 19 Cam Operated Rotary Switches Cam Operated Rotary Switches Single Hole Mounting (22.5mm cutout) Key Lockabale B63 Locking lever B19/B14 3 3 Max. Panel gap S Drilling plan S Ø5.5 A 3 to 5 Panel gap 48 13 48 B5 F D F D B2 L IP65 protection from front Features: n Single hole mounting with std dia 22.5 mm n Eliminates the need for screws/hardware for Quick-Fit Single Hole panel fixing n Easy termination n Available upto 32Amp B33 H A 23 Drilling plan Length L = No of Stages x S + W L Quote B14 for next bigger size front plate (available for 6/10Amps. only) Type Code A D F S S6/S10/TP6/TP10 B19 25 38 32 9.5 13.5 28.5 10 B14 27 38 48 9.5 13.5 28.5 10 S16/TP16/RT16/TP20/RT20 B19 S25/S32/RT25/RT32 32 B19 58 32 48 64 12 48 15 H IP40 protection from front W 13 36 13 37 Max 8 6 Pad Lockable Mountings S Drilling plan ØB3 3 to 5 Panel gap ON ØB2 B4 Length L = No of Stages x S + W Features: n Knob/Handle operatable Switch With key lockable assembly prevents switching by unauthorised personnel n Key lock/Key removable only in OFF position by default, key lockable and removable in any other position to be specified n Lock assembly can also be provided on any side n Common key for all Switches Features : Type B2 B4 B5 D F S W 35 13 23 43.5 58 64 12 45 Max 21 S25/S32/RT25/RT32 35 13 23 43.5 64 64 15 45 15 S40/S63/RT40/RT63 44 13 23 43.5 95 64 21 47 10 Enclosure D B17 A S16/TP16/RT16/TP20/RT20 LR/HR Model Ø5 .5 .5 L H J G Length L = No of Stages x S + W Ø5 .5 Ø5 SQ B1 F A L B F-48mm with B1-36mm also available on request for 16,25,32Amps Type B1 B2 B3 D F S W 44 36 12 4.5 58 65 12 26 Max 6 S25/S32/RT25/RT32 44 36 12 4.5 64 65 15 27 6 S40/S63/RT40/RT63 48 68 15 5.5 95 95 21 33 6 S80/S100/S125 48 68 15 5.5 118 95 26 40 6 E DrillingI plan 48 68 15 5.5 99 95 32 40 6 IP55 48 68 15 5.5 99 95 64 40 3 Features: n Switch mounted in ABS Enclosure n Provides protection from dust and hazardous material with regular Front Plate and Knob n Suitable for all switching angles n Knob/Handle operatable n IP65 can be given on request 3 to 5 Panel gap H Drilling plan F1 Ø5.5 B2 0 D E A Drilling plan F2 D 1 B Ø4.5 S200 S A SM, M S400 B30 D L A S16/TP16/RT16/TP20/RT20 SQ F Features: hole round padlockable mounting n Secure with max. 3 padlocks in OFF position prevents switching ON by unauthorised personnel n Suitable for switches only with 900 switching angle n Four G IP55 protection from front Quote B31 (B17 Enclosure and B33 Round Padlock) only for Isolater ON/OFF Switches B1 L A Features: hole rectangular padlockable mounting n Secure with max four padlocks in OFF position n Prevents switching only n Unauthorised personnel n Suitable for switches with 90switching angle n Four n Available 18 Type S16/TP16/RT16/TP20/RT20 Box Type A L B D E G Stages S6/S10/TP6/TP10 SM 28 125 100 72 80 115 4 S16/TP16/RT16 SM 28 125 100 72 80 115 3 S16/TP16/RT16 F3 Length L = No of Stages x S + W IP55 protection from front Type S25/S32/RT25/RT32 M 28 175 125 90 105 155 4 SM 35 125 100 72 80 115 2 A B1 B2 D F1 F2 F3 H S W Max S25/S32/RT25/RT32 M 35 175 125 90 105 155 4 35 48 58 76 104 12 23 12 26 S40/S63/RT40/RT63 M 44 175 125 90 105 155 2 I J - - 12 6 S25/S32/RT25/RT32 35 48 12 64 76 104 12 23 15 27 6 S40/S63/RT40/RT63 44 68 15 95 99 128 15 25 21 33 6 S80/S100/S125 44 68 15 118 99 128 15 25 26 40 6 S200 44 68 15 99 99 128 15 25 32 40 6 S400 44 68 15 99 99 128 15 25 64 40 3 Type Code A L B D E G H S25/S32/RT25/RT32 LR 38 130 115 161 87 102 100 S40/S63/RT40/RT63 HR 46 180 155 220 120 100 - 122 147 Stages 5 5 in Yellow/Red only 19 Cam Operated Rotary Switches M17 Cam Operated Rotary Switches B42 Metal Enclosure Door Interlock D1 Drilling Plan Front 2Holes 3 to 5mm panel gap A3 B2 A2 2 SQ F SQ F1 ØA3 Rubber grommet SQ D D2 ØD 1 Back A2 L 0 A1 R 120 D3 S G L1 C SQ-A1 Features: n Switches mounted in sheet metal Enclosures provides protection from hazardous environment n Knob/Handle operatable n Suitable for Switches upto 32Amp B02 IP55 protection from front Type A1 A2 A3 D1 D2 D3 Max S6/S10/TP6/TP10 70 60 6 85 89 98 4 S16/TP16/RT16/TP20/RT20 70 60 6 85 89 98 4 S25/S32/RT25/RT32 70 60 6 85 89 98 4 16A Forward/OFF/Reverse Only 70 60 5 75 75 110 -- Rear Mounting Back 3 to 5 B3 on rear side of the panel and operated from the front door n Door interlockable mechanism and panel door openable only in OFF position n Provides safety feature n Knob/Handle oparatable Drilling plan plate A2 B2 Panel gap B03 F B Length L = No of Stages x S + W L = L1 + C Features: n Mounted Front Drilling plan plate S Quote B41 for door openable in both positions without door interlock Type S16/TP16/RT16 TP20/RT20 A A1 A2 A3 B1 F B G C N S W Max 35 48 4.5 15 48 64 64 3.5 25 22 12 54 8 S25/S32/RT25/RT32 35 48 4.5 15 48 64 64 3.5 25 22 15 57 8 S40/S63/RT40/RT63 44 68 5.5 18 83 88 104 5 27 26 21 66 6 S80/S100/S125 44 68 5.5 18 100 88 124 5 27 26 26 72 6 S200 44 68 5.5 18 83 88 104 5 27 26 32 72 6 S400 44 68 5.5 18 83 88 104 8 27 26 64 72 3 Standard Mounting-Spring Return (Square Latching Mechanism) B21 Drilling plan Ø12 Type A A1 B1 B2 B3 F B G S W Max S6/S10/TP6/TP10 28 36 36 9 4.5 48 48 4.5 9.5 26 12 S16/TP16/RT16/TP20/RT20 28 36 48 12 4.5 48 64 3.5 12 30 12 S25/S32/RT25/RT32 35 48 48 12 4.5 64 64 3.5 15 31 8 S40/S63/RT40/RT63 43 68 68 15 5.5 88 88 5 21 41 6 S80/S100/S125 43 68 100 15 5.5 88 124 5 26 48 6 S200 43 68 83 15 5.5 88 104 5 32 48 6 S400 43 68 83 15 5.5 88 104 8 64 48 3 DIN Rail Mounting 10 F D 56 SQ. 64 SQ. 64 IP55 protection from front B13 for 16A Features: B03 for 25A/32A (without key) B90 for 25A/32A 0 1 2 0 2 1 (with center key) Available in black plate/black PG handle For B03 without key & for B90 with center kKey B1 A L 69 4 hole front panel mounting pistol grip handle operatable n Suitable for 450/600 only n Advanced special star/spring design on latching provides guaranted spring return operation Panel gap SQ 48 L n Standard Drilling plan Ø4.5 ØB2 3 to 5 ØD Length L = No of Stages x S + W S 20 Ø4.5 S L Ø4 Features: n Snap mounting base on DIN EN50022 (Omega) Rail 35mm and 1.2mm thick or two hole rear mounting n Provides easy termination n Can also be used for panel/door mounting 3 to 5mm Panel gap A1 B1 G Features: n Four hole base mounted on rear side of the panel n Knob/Handle operatable n Can also be used for panel/door mounting SQ-B1 A Isolators by default with knob only Length L = No of Stages x S + W Type L (No. of Stages) Type A B1 B2 D F S W Max 1 2 S6/S10/TP6/TP10 28 36 9 38 48 9.5 28.5 10 S16 / TP16 / RT16 (B13) 52.5 64.5 76.5 88.5 100.5 112.5 124.5 3 4 5 6 7 S16/TP16/RT16/TP20/RT20 28 36 12 58 48 12 37 12 S25 / S32 / RT25 / RT32 55.5 70.5 85.5 100.5 115.5 130.5 145.5 S25/S32/RT25/RT32 35 48 12 64 64 15 38 8 21 Cam Operated Rotary Switches M17 Cam Operated Rotary Switches B42 Metal Enclosure Door Interlock D1 Drilling Plan Front 2Holes 3 to 5mm panel gap A3 B2 A2 2 SQ F SQ F1 ØA3 Rubber grommet SQ D D2 ØD 1 Back A2 L 0 A1 R 120 D3 S G L1 C SQ-A1 Features: n Switches mounted in sheet metal Enclosures provides protection from hazardous environment n Knob/Handle operatable n Suitable for Switches upto 32Amp B02 IP55 protection from front Type A1 A2 A3 D1 D2 D3 Max S6/S10/TP6/TP10 70 60 6 85 89 98 4 S16/TP16/RT16/TP20/RT20 70 60 6 85 89 98 4 S25/S32/RT25/RT32 70 60 6 85 89 98 4 16A Forward/OFF/Reverse Only 70 60 5 75 75 110 -- Rear Mounting Back 3 to 5 B3 on rear side of the panel and operated from the front door n Door interlockable mechanism and panel door openable only in OFF position n Provides safety feature n Knob/Handle oparatable Drilling plan plate A2 B2 Panel gap B03 F B Length L = No of Stages x S + W L = L1 + C Features: n Mounted Front Drilling plan plate S Quote B41 for door openable in both positions without door interlock Type S16/TP16/RT16 TP20/RT20 A A1 A2 A3 B1 F B G C N S W Max 35 48 4.5 15 48 64 64 3.5 25 22 12 54 8 S25/S32/RT25/RT32 35 48 4.5 15 48 64 64 3.5 25 22 15 57 8 S40/S63/RT40/RT63 44 68 5.5 18 83 88 104 5 27 26 21 66 6 S80/S100/S125 44 68 5.5 18 100 88 124 5 27 26 26 72 6 S200 44 68 5.5 18 83 88 104 5 27 26 32 72 6 S400 44 68 5.5 18 83 88 104 8 27 26 64 72 3 Standard Mounting-Spring Return (Square Latching Mechanism) B21 Drilling plan Ø12 Type A A1 B1 B2 B3 F B G S W Max S6/S10/TP6/TP10 28 36 36 9 4.5 48 48 4.5 9.5 26 12 S16/TP16/RT16/TP20/RT20 28 36 48 12 4.5 48 64 3.5 12 30 12 S25/S32/RT25/RT32 35 48 48 12 4.5 64 64 3.5 15 31 8 S40/S63/RT40/RT63 43 68 68 15 5.5 88 88 5 21 41 6 S80/S100/S125 43 68 100 15 5.5 88 124 5 26 48 6 S200 43 68 83 15 5.5 88 104 5 32 48 6 S400 43 68 83 15 5.5 88 104 8 64 48 3 DIN Rail Mounting 10 F D 56 SQ. 64 SQ. 64 IP55 protection from front B13 for 16A Features: B03 for 25A/32A (without key) B90 for 25A/32A 0 1 2 0 2 1 (with center key) Available in black plate/black PG handle For B03 without key & for B90 with center kKey B1 A L 69 4 hole front panel mounting pistol grip handle operatable n Suitable for 450/600 only n Advanced special star/spring design on latching provides guaranted spring return operation Panel gap SQ 48 L n Standard Drilling plan Ø4.5 ØB2 3 to 5 ØD Length L = No of Stages x S + W S 20 Ø4.5 S L Ø4 Features: n Snap mounting base on DIN EN50022 (Omega) Rail 35mm and 1.2mm thick or two hole rear mounting n Provides easy termination n Can also be used for panel/door mounting 3 to 5mm Panel gap A1 B1 G Features: n Four hole base mounted on rear side of the panel n Knob/Handle operatable n Can also be used for panel/door mounting SQ-B1 A Isolators by default with knob only Length L = No of Stages x S + W Type L (No. of Stages) Type A B1 B2 D F S W Max 1 2 S6/S10/TP6/TP10 28 36 9 38 48 9.5 28.5 10 S16 / TP16 / RT16 (B13) 52.5 64.5 76.5 88.5 100.5 112.5 124.5 3 4 5 6 7 S16/TP16/RT16/TP20/RT20 28 36 12 58 48 12 37 12 S25 / S32 / RT25 / RT32 55.5 70.5 85.5 100.5 115.5 130.5 145.5 S25/S32/RT25/RT32 35 48 12 64 64 15 38 8 21 Cam Operated Rotary Switches Cam Operated Rotary Switches Knobs / Handle Colours TD - TEAR DROP RED BLACK Accessories Standard Style Front Plate Current Ratings FL - FLAG KNOB A Frame Size Bigger Style Current Ratings SQ20 Knobs and Handles 6/10Amps --- A SQ36 C C B B SQ32 16/20Amps D 6/10Amps D CODE - TD A B C D S6/S10/TP6/TP10 27 41 25 21 S6/S10/TP6/TP10 17 23 13.75 19 S16/TP16/RT16 27 41 25 21 S16/TP16/RT16 27 38 24 23 S25/S32/RT25/RT32 36 51 31 25 S25/S32/RT25/RT32 27 38 24 23 S25/S32/RT25/RT32 50 70 42 33 S25/S32/RT25/RT32 50 68 42.5 32 B C D 25/32Amps SQ64 LV - Lever Handle BG - Ball Grip Handle 16/20Amps SQ68 PG - Pistol Grip Handle A SQ48 SQ48 CODE - FL S40Amps & above 25/32Amps A A A C Sq81 --- C B B C B SQ88 S40Amps & above D SQ104 D D Special Front Plates CODE - PG A S16/TP16/RT16/TP20/RT20 36 B C D CODE - BG A 102 82 56 S16/TP16/RT16/TP20/RT20 36 B C D CODE - LV A B C D 100 67 45 S80/S100/S125 50 115 90 45 S200/S400 50 115 90 45 48 x 60 --- 48 102 82 56 S25/S32/RT25/RT32 36 100 67 45 S40/S63 36 102 82 56 S40/S63 36 100 67 45 64 x 80 Extended Terminals S25/S32/SG25 1.5 2 S63 8.5 8 27 9.5 8.5 15 S-Series 16 15 2-64020-00-001-401-14 3 Ø 8. 5 53 Rectangular 22 S63 22 0.8 45 0 0.8 61 Always mounted on Switch 95±0.2 Type D 22 S40/S63 2 Stage 25 3 Stage 34.5 35 50 54 75 L 4 45 0 1.5 S16/S25/S32 43±0.2 69±0.2 S6/S10 D 6.3 30.5 44 32 43 Ø 10.5 S6/S10/S16/TP16 6.3 S200 8 2 H Push On Terminals Extended Terminals - Always mounted on Switch H øD Type Supplied as optional for S40 and S63 on request S80/S100/S125 16/20Amps Protection Covers (Shrouds) 7.5 13.5 13.8 3.2 M4 12.5 25/32Amps R8 Ø 8.5 Ø 3.8 SQ48 S16 64 H 7.5 80 Accessories 60 36 SQ 36 S25/S32/RT25/RT32 10Amps 16Amps 20Amps S80 to S200 L D H 210 200 73 2 210 175 210 200 110 200 94 115 100 3 2 2 No. of Stages Mating terminal socket Code No : 1653 23 Cam Operated Rotary Switches Cam Operated Rotary Switches Knobs / Handle Colours TD - TEAR DROP RED BLACK Accessories Standard Style Front Plate Current Ratings FL - FLAG KNOB A Frame Size Bigger Style Current Ratings SQ20 Knobs and Handles 6/10Amps --- A SQ36 C C B B SQ32 16/20Amps D 6/10Amps D CODE - TD A B C D S6/S10/TP6/TP10 27 41 25 21 S6/S10/TP6/TP10 17 23 13.75 19 S16/TP16/RT16 27 41 25 21 S16/TP16/RT16 27 38 24 23 S25/S32/RT25/RT32 36 51 31 25 S25/S32/RT25/RT32 27 38 24 23 S25/S32/RT25/RT32 50 70 42 33 S25/S32/RT25/RT32 50 68 42.5 32 B C D 25/32Amps SQ64 LV - Lever Handle BG - Ball Grip Handle 16/20Amps SQ68 PG - Pistol Grip Handle A SQ48 SQ48 CODE - FL S40Amps & above 25/32Amps A A A C Sq81 --- C B B C B SQ88 S40Amps & above D SQ104 D D Special Front Plates CODE - PG A S16/TP16/RT16/TP20/RT20 36 B C D CODE - BG A 102 82 56 S16/TP16/RT16/TP20/RT20 36 B C D CODE - LV A B C D 100 67 45 S80/S100/S125 50 115 90 45 S200/S400 50 115 90 45 48 x 60 --- 48 102 82 56 S25/S32/RT25/RT32 36 100 67 45 S40/S63 36 102 82 56 S40/S63 36 100 67 45 64 x 80 Extended Terminals S25/S32/SG25 1.5 2 S63 8.5 8 27 9.5 8.5 15 S-Series 16 15 2-64020-00-001-401-14 3 Ø 8. 5 53 Rectangular 22 Type S63 22 Mating terminal socket Code No : 1653 0.8 45 0 0.8 61 Always mounted on Switch 95±0.2 3 Stage 34.5 35 50 54 75 Other special size mounting plates at Front or Rear can be supplied against requirement. D 22 S40/S63 2 Stage 25 L 4 45 0 1.5 S16/S25/S32 43±0.2 69±0.2 S6/S10 D 6.3 30.5 44 32 43 Ø 10.5 S6/S10/S16/TP16 6.3 S200 8 2 H Push On Terminals Extended Terminals - Always mounted on Switch H øD Type Supplied as optional for S40 and S63 on request S80/S100/S125 16/20Amps Protection Covers (Shrouds) 7.5 13.5 13.8 3.2 M4 12.5 25/32Amps R8 Ø 8.5 Ø 3.8 SQ48 S16 64 H 7.5 80 Accessories 60 36 SQ 36 S25/S32/RT25/RT32 10Amps 16Amps 20Amps S80 to S200 L D H 210 200 73 2 210 175 210 200 110 200 94 115 100 3 2 2 No. of Stages In case of fixing at site use supplied hardware only. 23 Cam Operated Rotary Switches Cam Operated Rotary Switches Customised Programme Front plate Programme Number Customised Programme Formation 73037 P Front plate Programme Number OFF 1 1 3 3 5 5 2 2 4 4 6 6 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 0 Switching angle 60 Switch positions OFF 1 3 9 7 5 11 13 15 17 19 21 23 25 27 29 31 33 35 TUBE TUBE & FAN FAN 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 FAN & LAMP NIGHT LAMP Switching angle X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Locked positions Switch Type 4 Switching positions 5 6 1 Front plate Contact Closed without interruption 2 Mounting 3 B03 Stop Form 7 Optional extras X Contact Closed 1 S 16 Type Colour 50 Yellow Spring return With Without X Marking Handle Type Tear drop Colour Red Customer Date CUSTOMER CODE No. 2 The Switch design and construction gives flexibility for making customised programmes within a very short period. Basically an engineer trying to specify the customised programme should concentrate on the following points. (a) Number of operating positions of Switch Handle (b) Total number of contacts required (c) Contact closing sequence of all the contacts required in various positions of handle. Please note : 1) Each position should be identified and script plate marking required in those positions should be mentioned. 2) The standard latching angle (angle between positions)/switching angles are 600, 900, 450 and 30. Spring Return are also possible for 450 and 900 switching angle. (d) Total number of contacts can be decided based on the actual need. You may arrange the contacts to your convenience and number them as ½,3/4, 5/6...etc. While making the Switch, we may rearrange the contacts to use solid Jumpers so as to avoid loose wire Jumpers. (e) Fill up the Programme sheet by marking ‘X’ at places where contacts have to Close (NC). Also specify the ampere rating, mounting style, switching angle, script plate markings, terminal marking and lockable position (If any). For example refer the sample customised programme sheet of a Bedroom Switch having 3 contacts controlling a tube, fan and night lamp. Note: The above construction carries a five digit number starting with (7xxxx) allotted by us. This number alone is sufficient for future correspondence and further ordering. Ordering Code 3 4 Type Programme Code 5 Ampere Mounting Knob Color T Y 6 7 Example : 8 6 1 1 Programme Selection 9 10 Programmes 11 Isolators Changeovers with OFF Changeovers without OFF Multistep with OFF Multistep without OFF Instrumentation Switches Motor Control Switches Gang Switches Control Switches 12 13 14 15 16 17 18 19 20 9 7 S 2 0 0 B 0 3 D R Type Selection Prog Code Pg 06 Pg 07 Pg 08 Pg 09 Pg 10 Pg 11 Pg 13 Pg 15 Pg 16 Type S-Series Touch Proof Rear Access Termination DC Switches Code S T R D Possible Amps 6 to 400Amps 6 to 20Amps 16 to 63Amps 16 to 500Amps Phase Selector only for 1 Pole 3 Way with OFF Ammeter (CT Operated) Voltmeter (Phase to Phase with OFF) P 25 to 63Amps P 6 and 10Amps (available only with four hole mounting) L - Series (Spring clamp screwless) L 6 to 10 Amps Ampere Code 6 10 16 20 25 32 40 63 80 A B C D E F G I J Ampere Code 100 125 200 250 300 400 500 K L N O P Q R Color Combination Selection 21 CODE - YR 22 CODE - GB CODE - BB CODE - AB 23 24 Locked position X X Contact closed 1 2 Switch Type 4 Front plate Size Colour Mounting Form Contact closed without interruption 3 Spring return With Position Without Yellow Front Plate Red Handle 7 Black Front Plate Black Handle Grey Front Plate Black Handle Alluminium (silver) Foil Front Plate with Black Handle Knobs and Handles Selection Optional extras CODE- TD 5 CODE- FH CODE - BG CODE- PG CODE- LV Marking 6 Handle Type Colour Customer Date Customer Code No. Tear Drop Handle 24 Flag Handle Ball Grip Handle Pistal Grip Handle Lever Handle 25 Cam Operated Rotary Switches Cam Operated Rotary Switches Customised Programme Front plate Programme Number Customised Programme Formation 73037 P Front plate Programme Number OFF 1 1 3 3 5 5 2 2 4 4 6 6 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 0 Switching angle 60 Switch positions OFF 1 3 9 7 5 11 13 15 17 19 21 23 25 27 29 31 33 35 TUBE TUBE & FAN FAN 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 FAN & LAMP NIGHT LAMP Switching angle X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Locked positions Switch Type 4 Switching positions 5 6 1 Front plate Contact Closed without interruption 2 Mounting 3 B03 Stop Form 7 Optional extras X Contact Closed 1 S 16 Type Colour 50 Yellow Spring return With Without X Marking Handle Type Tear drop Colour Red Customer Date CUSTOMER CODE No. 2 The Switch design and construction gives flexibility for making customised programmes within a very short period. Basically an engineer trying to specify the customised programme should concentrate on the following points. (a) Number of operating positions of Switch Handle (b) Total number of contacts required (c) Contact closing sequence of all the contacts required in various positions of handle. Please note : 1) Each position should be identified and script plate marking required in those positions should be mentioned. 2) The standard latching angle (angle between positions)/switching angles are 600, 900, 450 and 30. Spring Return are also possible for 450 and 900 switching angle. (d) Total number of contacts can be decided based on the actual need. You may arrange the contacts to your convenience and number them as ½,3/4, 5/6...etc. While making the Switch, we may rearrange the contacts to use solid Jumpers so as to avoid loose wire Jumpers. (e) Fill up the Programme sheet by marking ‘X’ at places where contacts have to Close (NC). Also specify the ampere rating, mounting style, switching angle, script plate markings, terminal marking and lockable position (If any). For example refer the sample customised programme sheet of a Bedroom Switch having 3 contacts controlling a tube, fan and night lamp. Note: The above construction carries a five digit number starting with (7xxxx) allotted by us. This number alone is sufficient for future correspondence and further ordering. Ordering Code 3 4 Type Programme Code 5 Ampere Mounting Knob Color T Y 6 7 Example : 8 6 1 1 Programme Selection 9 10 Programmes 11 Isolators Changeovers with OFF Changeovers without OFF Multistep with OFF Multistep without OFF Instrumentation Switches Motor Control Switches Gang Switches Control Switches 12 13 14 15 16 17 18 19 20 9 7 S 2 0 0 B 0 3 D R Type Selection Prog Code Pg 06 Pg 07 Pg 08 Pg 09 Pg 10 Pg 11 Pg 13 Pg 15 Pg 16 Type S-Series Touch Proof Rear Access Termination DC Switches Code S T R D Possible Amps 6 to 400Amps 6 to 20Amps 16 to 63Amps 16 to 500Amps Phase Selector only for 1 Pole 3 Way with OFF Ammeter (CT Operated) Voltmeter (Phase to Phase with OFF) P 25 to 63Amps P 6 and 10Amps (available only with four hole mounting) L - Series (Spring clamp screwless) L 6 to 10 Amps Ampere Code 6 10 16 20 25 32 40 63 80 A B C D E F G I J Ampere Code 100 125 200 250 300 400 500 K L N O P Q R Color Combination Selection 21 CODE - YR 22 CODE - GB CODE - BB CODE - AB 23 24 Locked position X X Contact closed 1 2 Switch Type 4 Front plate Size Colour Mounting Form Contact closed without interruption 3 Spring return With Position Without Yellow Front Plate Red Handle 7 Black Front Plate Black Handle Grey Front Plate Black Handle Alluminium (silver) Foil Front Plate with Black Handle Knobs and Handles Selection Optional extras CODE- TD 5 CODE- FH CODE - BG CODE- PG CODE- LV Marking 6 Handle Type Colour Customer Date Customer Code No. Tear Drop Handle 24 Flag Handle Ball Grip Handle Pistal Grip Handle Lever Handle 25 Cam Operated Rotary Switches Cam Operated Rotary Switches Breaker Control Switches Mounting Styles Under this 3 types are widely used a) Spring return b) Lost Motion contact (LMD) c) Sequence Locking (Two consecutive movement in one direction arrested) NEUTRAL T R I P All the above can also be with external KEY and LOCK arrangement. In LMD, the contact block is divided into two, as main contacts and LMD contacts. LMD Contacts will be closed with the handle is moved to CLOSE side/TRIP side and the contact closing will be retained even though the handle is returned to the NEUTRAL by virtue of Spring Return nature. When the handle is rotated on the opposite direction then only the LMD contact will open. Thus the LMD mechanism enables the Switch to have a memory feature of the previous operation, which is considered to be a very essential for Circuit Breaker applications. In case of sequence lock, it acts like a mechanical interlock in the switch not permitting two consecutive “CLOSE” operations. When you Turn the handle to CLOSE Position and handle will be back to NEUTRAL due to Spring Return action. Again the handle movement on the CLOSE side will be locked. When the handle is moved to TRIP position then only rotation to CLOSE position permitted. Description Rated Operational Voltage Ue Resistance to Surge Voltage Rated Uninterrupted Current Uimp Ith Ie Rated Operational Current Pilot Duty Ac15 220-240V AC 380-440V AC Short circuit protection HRC fuse size Rated short circuit Terminal cross section min Rigid wire max Flexible wire min max Terminal Screw Terminal Tightening Torque Voltage 50V 125V 250V 26 No of Contacts in series 1 2 3 1 2 3 1 2 3 Unit S25 V AC V DC kV A 690 250 6 32 690 250 6 40 A A 8 5 25 14 6 32 kA 10 10 mm2 1.5 4 1 2.5 M4 1.2 Nm 2.5 6 1.5 4 M4 1.2 Nm A mm2 S32 S25/SG 25 S32/SG32 Inductive L/R Amps Inductive L/R Amps Resistive Resistive 40 10 20 40 10 20 Amps Amps msec msec msec msec msec msec 20 20 15 6 25 25 18 8 20 14 25 18 20 25 3 2.5 1.5 1.0 5 3 2 1.2 20 15 10 5 25 18 12 6 20 20 10 25 25 12 1.0 0.5 0.3 0.2 1.2 0.6 0.4 0.3 5 2 1.0 0.5 6 2.5 1.2 0.6 20 10 4 1 25 12 5 1.2 Ø 12 82 ! Spring Return to Neutral Position from both the sides ! Memory feature of the previous Operation(LMD) ! Permits only one Close Operation(Sequential Lock) As indicated all the above feature models can also be supported with external lock and key arrangement with key lockable and removable only at NEUTRAL position and the handle shall not be turned when the key is in locked condition. Technical Specifications Drilling plan Ø 4.5 C L O S E Ø58 In SPRING RETURN type the handle is always return to NEUTRAL position and does not stay in other TWO positions, when the handle returned to Neutral the Main/TRIP contact will be in open condition. 3 to 5mm Panel gap S L 78 B90 SQ. 64 SQ. 64 NEUTRAL NEUTRAL Shorter length handle also available on request Type T R I P C L O S E T R I P General Endurance : Mechanical 100,000 operations at 300 cycles/hour Electrical 10,000 operations at 120 cycles/hour Operational Temperature 250C to 550C, frequency upto 5 kHz SQ 48 B03 S25/S32 C L O S E X* LMD Y* Sequential Lock L (No.of Stages) 1 2 3 4 5 6 7 53 68 83 98 113 128 143 15 27.5 *LMD Dimension ‘X’ to be added *Sequential Lock Dimension ‘Y’ to be added B90 is available only black front plate & black PG handle type Installation Procedure for Barrel Lock (Center Key Lock) Panel Fixing Screw Ensure Mating Orientation with Knob Switch Mounting Plate Panel Thickness 3 To 5mm c Barrel Lock Assembly 27 Cam Operated Rotary Switches Cam Operated Rotary Switches Breaker Control Switches Mounting Styles Under this 3 types are widely used a) Spring return b) Lost Motion contact (LMD) c) Sequence Locking (Two consecutive movement in one direction arrested) NEUTRAL T R I P All the above can also be with external KEY and LOCK arrangement. In LMD, the contact block is divided into two, as main contacts and LMD contacts. LMD Contacts will be closed with the handle is moved to CLOSE side/TRIP side and the contact closing will be retained even though the handle is returned to the NEUTRAL by virtue of Spring Return nature. When the handle is rotated on the opposite direction then only the LMD contact will open. Thus the LMD mechanism enables the Switch to have a memory feature of the previous operation, which is considered to be a very essential for Circuit Breaker applications. In case of sequence lock, it acts like a mechanical interlock in the switch not permitting two consecutive “CLOSE” operations. When you Turn the handle to CLOSE Position and handle will be back to NEUTRAL due to Spring Return action. Again the handle movement on the CLOSE side will be locked. When the handle is moved to TRIP position then only rotation to CLOSE position permitted. Description Rated Operational Voltage Ue Resistance to Surge Voltage Rated Uninterrupted Current Uimp Ith Ie Rated Operational Current Pilot Duty Ac15 220-240V AC 380-440V AC Short circuit protection HRC fuse size Rated short circuit Terminal cross section min Rigid wire max Flexible wire min max Terminal Screw Terminal Tightening Torque Voltage 50V 125V 250V 26 No of Contacts in series 1 2 3 1 2 3 1 2 3 Unit S25 V AC V DC kV A 690 250 6 32 690 250 6 40 A A 8 5 25 14 6 32 kA 10 10 mm2 1.5 4 1 2.5 M4 1.2 Nm 2.5 6 1.5 4 M4 1.2 Nm A mm2 S32 S25/SG 25 S32/SG32 Inductive L/R Amps Inductive L/R Amps Resistive Resistive 40 10 20 40 10 20 Amps Amps msec msec msec msec msec msec 20 20 15 6 25 25 18 8 20 14 25 18 20 25 3 2.5 1.5 1.0 5 3 2 1.2 20 15 10 5 25 18 12 6 20 20 10 25 25 12 1.0 0.5 0.3 0.2 1.2 0.6 0.4 0.3 5 2 1.0 0.5 6 2.5 1.2 0.6 20 10 4 1 25 12 5 1.2 Ø 12 82 ! Spring Return to Neutral Position from both the sides ! Memory feature of the previous Operation(LMD) ! Permits only one Close Operation(Sequential Lock) As indicated all the above feature models can also be supported with external lock and key arrangement with key lockable and removable only at NEUTRAL position and the handle shall not be turned when the key is in locked condition. Technical Specifications Drilling plan Ø 4.5 C L O S E Ø58 In SPRING RETURN type the handle is always return to NEUTRAL position and does not stay in other TWO positions, when the handle returned to Neutral the Main/TRIP contact will be in open condition. 3 to 5mm Panel gap S L 78 B90 SQ. 64 SQ. 64 NEUTRAL NEUTRAL Shorter length handle also available on request Type T R I P C L O S E T R I P General Endurance : Mechanical 100,000 operations at 300 cycles/hour Electrical 10,000 operations at 120 cycles/hour Operational Temperature 250C to 550C, frequency upto 5 kHz SQ 48 B03 S25/S32 C L O S E X* LMD Y* Sequential Lock L (No.of Stages) 1 2 3 4 5 6 7 53 68 83 98 113 128 143 15 27.5 *LMD Dimension ‘X’ to be added *Sequential Lock Dimension ‘Y’ to be added B90 is available only black front plate & black PG handle type Installation Procedure for Barrel Lock (Center Key Lock) Panel Fixing Screw Ensure Mating Orientation with Knob Switch Mounting Plate Panel Thickness 3 To 5mm c Barrel Lock Assembly 27 Cam Operated Rotary Switches Cam Operated Rotary Switches Installation Procedure-Standard Switch DC Switches (CPRI Tested & RDSO Approved) Construction and Features D16 - D63 D Series Switches are designed for DC Switching applications. These Switches are Constructed using snap action mechanism which provides "Quick Make Quick Break" of the contacts which is essential for DC switching. The contacts are of AgCdO, double break and butt type housed in a glass filled polyamide contact stage and are operated through cams for higher electrical endurance and smooth operation. Panel Fixing Nut Suitable for 90 and 60 degree switching programmes and applicable for bothAC and DC Switching. Suitable switching programmes for Isolator, Changeover, Multi-step and Gang Switches etc. are offered. *Ensure Mating Orientation with Knob Switch DC Switches D100A-D500A Features: Housing made up of SMC material for rigidity and higher mechanical strength. n “Wiping contacts” operations helps in dust free & self cleaning concepts n Extended terminals for Bus bar / Aluminium cable connections n Capston Handle Operation for better leverage. n Mounting Plate Applications: D40R – Railway coaches lighting & fan circuits switching n ‘All DC power circuits – Railways, Telecommunications & Power plants n Battery charging equipments n Panel Thickness 3 To 5mm Front Plate & Panel Screw Fixing Technical Specifications Rated Operational Current le DC Ratings Unit Description Rated on Interrupted Current (l th) Front Plate No of Series Contacts Raster Plate Ring D 16 D 25 D 32 D 40 D 63 A 20 32 40 50 80 A 16 25 32 40 63 HP A A kA mm2 mm2 Nm 7 16 16 5 1.5 4 0.8 10 25 25 10 1.5 4 1.2 14 32 32 10 1.5 6 1.2 20 40 40 20 1.5 10 2 25 63 63 20 1.5 16 2 16 10 10 6 6 UNIT D 100 D 200 D 300 D 400 D 500 V DC V AC A A Deg 250 460 100 125 90 9 250 460 200 250 90 9 250 460 300 375 90 9 250 460 400 500 90 9 250 460 500 625 90 9 DC 22A L/R 2m sec Rated Operational Voltage Script Plate AC Ratings Knob General 110 V 250 V 1 2 AC3 Rating 3 Phase 380-440V AC21 Rating Fuse Protection Short Circuit through fault current [Rigid] min Terminal Cross Section [Flex] max Tightening Torque Maximum Contact Stages Knob Screw Switch Type Description Duty Rating - DC 22 A L/R 2m sec Operational Voltage Voltage for AC Rating Operational Current Thermal Current (l th) Switching Angle Maximum Contact Stages 28 29 Cam Operated Rotary Switches Cam Operated Rotary Switches Installation Procedure-Standard Switch DC Switches (CPRI Tested & RDSO Approved) Construction and Features D16 - D63 D Series Switches are designed for DC Switching applications. These Switches are Constructed using snap action mechanism which provides "Quick Make Quick Break" of the contacts which is essential for DC switching. The contacts are of AgCdO, double break and butt type housed in a glass filled polyamide contact stage and are operated through cams for higher electrical endurance and smooth operation. Panel Fixing Nut Suitable for 90 and 60 degree switching programmes and applicable for bothAC and DC Switching. Suitable switching programmes for Isolator, Changeover, Multi-step and Gang Switches etc. are offered. *Ensure Mating Orientation with Knob Switch DC Switches D100A-D500A Features: Housing made up of SMC material for rigidity and higher mechanical strength. n “Wiping contacts” operations helps in dust free & self cleaning concepts n Extended terminals for Bus bar / Aluminium cable connections n Capston Handle Operation for better leverage. n Mounting Plate Applications: D40R – Railway coaches lighting & fan circuits switching n ‘All DC power circuits – Railways, Telecommunications & Power plants n Battery charging equipments n Panel Thickness 3 To 5mm Front Plate & Panel Screw Fixing Technical Specifications Rated Operational Current le DC Ratings Unit Description Rated on Interrupted Current (l th) Front Plate No of Series Contacts Raster Plate Ring D 16 D 25 D 32 D 40 D 63 A 20 32 40 50 80 A 16 25 32 40 63 HP A A kA mm2 mm2 Nm 7 16 16 5 1.5 4 0.8 10 25 25 10 1.5 4 1.2 14 32 32 10 1.5 6 1.2 20 40 40 20 1.5 10 2 25 63 63 20 1.5 16 2 16 10 10 6 6 UNIT D 100 D 200 D 300 D 400 D 500 V DC V AC A A Deg 250 460 100 125 90 9 250 460 200 250 90 9 250 460 300 375 90 9 250 460 400 500 90 9 250 460 500 625 90 9 DC 22A L/R 2m sec Rated Operational Voltage Script Plate AC Ratings Knob General 110 V 250 V 1 2 AC3 Rating 3 Phase 380-440V AC21 Rating Fuse Protection Short Circuit through fault current [Rigid] min Terminal Cross Section [Flex] max Tightening Torque Maximum Contact Stages Knob Screw Switch Type Description Duty Rating - DC 22 A L/R 2m sec Operational Voltage Voltage for AC Rating Operational Current Thermal Current (l th) Switching Angle Maximum Contact Stages 28 29 Cam Operated Rotary Switches Cam Operated Rotary Switches D16 D63 D200-D500 Panel Gap Ø10.5 Drilling Plan øB2 øD SQ F Ø32 Ø10.5 3 S 24.5 3 24.5 33.5 Ø3.1 S 170 PCD øB3 236 3 to 5 Ø10.5 105 0.8 138 L L SQ 35.5 Type B1 B2 B3 D B1 Type F S D 16 48 12 5.5 50 64 12 D 25 / D 32 48 12 5.5 50 64 15 D 40 / D 63 68 15 5.5 70 88 21 Length L S 22 D200-D500 5.0 35 3 4 5 6 7 117 139 161 183 205 D100 with Door Interlock 120 2 3 4 5 6 7 8 9 10 11 12 D 16 62 74 86 98 110 122 134 146 158 170 182 194 D 25/32 65 80 95 110 125 140 155 170 185 200 215 230 D 40/63 69 90 111 132 153 174 195 216 237 258 279 300 170 PCD 0.8 3.1 Ø34.5 PCD 44 Length L in mm 1 M5 D40 R M6 R200 S S1 59 105 90 SI Ø19 24.5 24.5 PO 90 S2 L 80 41.5 26 L Type S S1 S2 D100 32 35 15 133 Type S S1 S2 D40 10 30.5 15 Length L 1 2 3 4 5 6 7 8 210 242 274 306 338 370 402 434 Length L 5 4 1 2 3 55.5 65.5 75.5 7 6 8 85.5 95.5 105.5 115.5 125.5 D200-D500 with Door Interlock 120 Ø10.5 L = No. of Stages x S + (S+S) Ø10.5 105 Ø10.5 170 PCD 0.8 Rectangle Slot 33X20 170 PCD D100 0.8 236 Ø10.5 Ø3.1 24.5 33.5 35 L S S1 S2 D100 32 32 15 24.5 3 5.0 24.5 S 3 Ø3.1 Ø32 R200 3 S S1 S2 Type Ø4.3 (2Nos.) Ø34.5 PCD 44 236 Ø10.5 30 236 Stages 80 L 138 Length L 1 2 3 4 5 6 7 112 144 176 208 240 272 304 Type D200-D500 S 22 Length L 3 4 5 6 7 197 219 241 263 285 31 Cam Operated Rotary Switches Cam Operated Rotary Switches D16 D63 D200-D500 Panel Gap Ø10.5 Drilling Plan øB2 øD SQ F Ø32 Ø10.5 3 S 24.5 3 24.5 33.5 Ø3.1 S 170 PCD øB3 236 3 to 5 Ø10.5 105 0.8 138 L L SQ 35.5 Type B1 B2 B3 D B1 Type F S D 16 48 12 5.5 50 64 12 D 25 / D 32 48 12 5.5 50 64 15 D 40 / D 63 68 15 5.5 70 88 21 Length L S 22 D200-D500 5.0 35 3 4 5 6 7 117 139 161 183 205 D100 with Door Interlock 120 2 3 4 5 6 7 8 9 10 11 12 D 16 62 74 86 98 110 122 134 146 158 170 182 194 D 25/32 65 80 95 110 125 140 155 170 185 200 215 230 D 40/63 69 90 111 132 153 174 195 216 237 258 279 300 170 PCD 0.8 3.1 Ø34.5 PCD 44 Length L in mm 1 M5 D40 R M6 R200 S S1 59 105 90 SI Ø19 24.5 24.5 PO 90 S2 L 80 41.5 26 L Type S S1 S2 D100 32 35 15 133 Type S S1 S2 D40 10 30.5 15 Length L 1 2 3 4 5 6 7 8 210 242 274 306 338 370 402 434 Length L 5 4 1 2 3 55.5 65.5 75.5 7 6 8 85.5 95.5 105.5 115.5 125.5 D200-D500 with Door Interlock 120 Ø10.5 L = No. of Stages x S + (S+S) Ø10.5 105 Ø10.5 170 PCD 0.8 Rectangle Slot 33X20 170 PCD D100 0.8 236 Ø10.5 Ø3.1 24.5 33.5 35 L S S1 S2 D100 32 32 15 24.5 3 5.0 24.5 S 3 Ø3.1 Ø32 R200 3 S S1 S2 Type Ø4.3 (2Nos.) Ø34.5 PCD 44 236 Ø10.5 30 236 Stages 80 L 138 Length L 1 2 3 4 5 6 7 112 144 176 208 240 272 304 Type D200-D500 S 22 Length L 3 4 5 6 7 197 219 241 263 285 31 Salzer Electronics Limited Samichettipalayam Coimbatore - 641 047, INDIA. Tel: +91 422 4233600/2692531. Fax: + 91422 2692170. Email: salzer@salzergroup.com, sales@salzergroup.com. Website: www.salzergroup.com n o h t c t i Sw he Bes t o t Intertek Cam Operated Rotary Switches