DSX Controller Addressing - DSX Access Systems, Inc.

advertisement
®
DSX Access Systems, Inc.
DSX Controller Addressing
Controller Addressing
Each Controller has an 8 position dipswitch to set its address. The Master Controller is addressed as the
Location number and has switch 8 turned on. Turn on switches 1-7 to set the Location number. Each switch
has a binary value and when added together equal the Location number. Add the values of each switch
turned on. To set the Master address above 127 set switches 1-7 off and program the address using
KB2CW.exe from the WinDSX directory.
Set the Slave device address starting at 2. Both Devices of all controllers must be defined in the database
but only the even number is programmed by the dipswitches. Side A = even number set by the switches.
Side B = next highest odd number.
The Master is always device address 0 & 1 in the database. Switch 8 is only turned on at the Master
Controller.
DSX-1048 Controller Addressing
Communications
Method
32,000 Locations per Host PC
/ Comm Server
1 Location Can Include:
(Up to 64 Controllers)
(1 Master and 63 Slaves)
(128 Devices)
S
N WI
U T
M C
BE H
R
First Controller is Location Master
Devices 0 & 1
(Master controller)
104x
Devices 2 & 3
(1st Slave controller)
104x
Devices 4 & 5
(2nd Slave controller)
104x
Devices 6 & 7
(3rd Slave controller)
104x
Communications
Distribution Module
1040CDM
IN
OUT
DIP Switch setting
for Master Controller
Switch 1 value = 1
Switch 8 = Master
Total value = Loc 1s
Master Controller
1
2
3
4
5
6
7
8
1
2
4
8
16
32
64
MAS/SLV
ON
DIP Switch setting
for first Slave
Switch 2 value = 2
Total value = 2
Switch 3 value = 4
Total value = 4
1
2
4
8
16
32
64
MAS/SLV
Switch 2 value = 2
Switch 3 value = 4
Total value = 6
OFF
1
2
3
4
5
6
7
8
1
2
4
8
16
32
64
MAS/SLV
ON
DIP Switch setting
for third Slave
OFF
1
2
3
4
5
6
7
8
ON
DIP Switch setting
for second Slave
SW
VA IT
LU CH
E
Equals ON
Equals OFF
Note /// Dip Switch Down on the Left Side = ON
Note /// Dip Switch Down on the Right Side = OFF
OFF
1
2
3
4
5
6
7
8
1
2
4
8
16
32
64
MAS/SLV
ON
OFF
Note /// Dip Switch at a Master panel
must equal the Location #.
Note /// Dip Switch at a Slave panel
must equal Device Address of Side A.
DSX Access Systems, Inc. 10731 Rockwall Road Dallas, Texas 75238 / 888-419-8353 / www.dsxinc.com
8/2011
DSX-1022 Controller Addressing
Comm
Method
32,000 Locations per Host PC
/ Comm Server
1 Location Can Include:
(Up to 64 Controllers)
(1Master and 63 Slaves)
(128 Devices)
Note /// Dip Switch Down on the Left Side = ON
Device
Address:
Location
#
S
N WI
U T
M C
BE H
R
First panel is Location Master
DIP Switch setting
for Master Controller
Location 1
Master
Devices
0&1
(MASTER)
Switch 1 value = 1
Switch 8 = Master
Total Value =
Loc 1s Master
RS-485
1
2
3
4
5
6
7
8
ON
Device
Address:
2
Devices
2&3
(SLAVE 1)
DIP Switch setting
for first Slave
Switch 2 value = 2
Total value = 2
RS-485
4
Devices
4&5
(SLAVE 2)
DIP Switch setting
for second Slave
Switch 3 value = 4
Total value = 4
RS-485
Device
Address:
6
Devices
6&7
(SLAVE 3)
Switch 2 value = 2
Switch 3 value = 4
Total value = 6
To addional Slave Controllers
OFF
1
2
4
8
16
32
64
MAS/SLV
OFF
1
2
3
4
5
6
7
8
1
2
4
8
16
32
64
MAS/SLV
ON
DIP Switch setting
for third Slave
1
2
4
8
16
32
64
MAS/SLV
1
2
3
4
5
6
7
8
ON
Device
Address:
SW
VA IT
LU CH
E
Equals ON
Equals OFF
Note /// Dip Switch Down on the Right Side = OFF
OFF
1
2
4
8
16
32
64
MAS/SLV
1
2
3
4
5
6
7
8
ON
OFF
Note /// Dip Switch at a Master panel must equal the Location #.
Note /// Dip Switch at a Slave panel must equal Device Address of
Side A.
DSX Access Systems, Inc. 10731 Rockwall Road Dallas, Texas 75238 / 888-419-8353 / www.dsxinc.com
8/2011
Download