TM 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 E. info@cristalcontrols.com cristalcontrols.com TM Index Quick Selection.....................................................................................................................................................3-4 Which Technology to use.......................................................................................................................................4 Retrofit Ceiling Occupancy Sensor.....................................................................................................................5 Low Voltage Ceiling Occupancy Sensor..........................................................................................................10 Line Voltage Ceiling Occupancy Sensor .........................................................................................................16 Line Voltage Ceiling Occupancy Sensor, 347VAC ...................................................................................... 22 Retrofit Wall Switch Occupancy Sensor .........................................................................................................27 Low Voltage Wall Switch Occupancy Sensor............................................................................................... 32 Low Voltage Wall Mount Occupancy Sensor................................................................................................ 38 Line Voltage Wall Switch Occupancy Sensor................................................................................................ 43 Line Voltage Wall Switch Occupancy Sensor, 347V...................................................................................48 1-Pole Power Pack (120-277-1).........................................................................................................................53 1-Pole Power Pack (347-1)................................................................................................................................. 56 2-Pole Power Pack (120-277-1)....................................................................................................................... 59 Sensor Settings...................................................................................................................................................... 62 Warranty...................................................................................................................................................................64 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com TM Quick Selection Chart CEILING LOW VOLTAGE PAGE CCORSDD1-N-N (Retrofit Applications Only) Ceiling Recessed, Std Lens, Dual Tech, 24V, 1P 3 CCORSDD1-R-N Ceiling Recessed, Std Lens, Dual, 24V, 1P, Rly 3 CCORSDD2-N-N Ceiling Recessed, Std Lens, Dual Tech, 24V, 2 Pole 8 CCORSDD2-R-N Ceiling Recessed, Std Lens,Dual Tech, 24V, 2 Pole, Rly 8 CCORXDD2-PR-N Ceiling Recessed, Ext Lens, Dual Tech, 24V, 2P, Ph, Rly 8 CCORSDD2-DPR-L Ceiling Rec, Std Lens, Dual Tech, 24V, 2P, Dim, Ph, Rly, LT 8 CCORXDD2-DPR-L Ceiling Rec, Ext Lens, Dual Tech, 24V, 2P, Dim, Ph, Rly, LT 8 CEILING LINE VOLTAGE PAGE CCORBIU2-P-N Ceiling Recessed, High Bay, PIR, 120/277, 2P, Photo 14 CCORSDU1-P-N Ceiling Recessed, Std Lens,Dual Tech, 120/277, 1P, Photo 14 CCORSDU2-P-N Ceiling Recessed, Std Lens, Dual Tech, 120/277, 2P, Photo 14 CCORXDU2-P-L Ceiling Recessed, Ext. Lens, Dual Tech, 120/277, 2P, Photo 14 CCORSD31-P-N Ceiling Recessed, Std Lens, Dual Tech, 347, 1P, Photo 20 CCORSD32-P-N Ceiling Recessed, Std Lens, Dual Tech, 347, 2P, Photo 20 CCORXD32-P-N Ceiling Recessed, Ext. Lens, Dual Tech, 347, 2P, Photo 20 WALL SWITCHES LOW VOLTAGE PAGE CCOSSDD1-P-VW (Retrofit Applications Only) Switch Mt Sensor, Dual Tech, 24V, 1P, Photo, Vandal, White 25 CCOSSDD2-P-VW Switch Mt Sensor, Dual Tech, 24V, 2P, Photo, Vandal, White 30 CCOSSDD2-DPR-VW Switch Mt Sensor, Dual Tech, 24V, 2P, Dim, Ph, Rly, Vandal, W 30 WALL MOUNT (Corner, aisles etc…) PAGE CCOWCDD2-R-N Wall Mount Sensor, Corner Lens, Dual Tech, 24V, 2P, Rly 36 CCOWLDD2-R-N Wall Mount Sensor, Large Area Lens, Dual Tech, 24V, 2P, Rly 36 CCOWCDD2-DPR-N Wall Mt Sensor, Corner Lens, Dual Tech, 24V, 2P, Dim, Ph, Rly 36 3 TM Quick Selection Chart & Which Technology to use Technical Data WALL SWITCHES LINE VOLTAGE PAGE CCOSSDU1-P-VW Switch Mt Sensor, Dual Tech, 120/277, 1P, Photo, Vandal, White 41 CCOSSDU2-P-VW Switch Mt Sensor, Dual Tech, 120/277, 2P, Photo, Vandal, White 41 CCVSSDU2-P-VW Switch Mt Vac. Sensor, Dual Tech, 120/277, 2P, Photo, Vandal, White 41 CCOSSD31-P-VW Switch Mt Sensor, Dual Tech, 347, 1P, Photo, Vandal, White 46 CCOSSD32-P-VW Switch Mt Sensor, Dual Techl, 347, 2P, Photo, Vandal, White 46 POWER PACK CCP-PP20-D CCP-PP20-2P CCP-PP20-347-D CCIR-3110 FEATURES WORSDD1-N-N WORXDD1-N-N u The Diver use PIR an technolog presence the contro occupanc detected. PAGE Douglas Retrofit Ceiling 51 Technical Data Power Pack, 120/277, 20A, 1P, 24VAC power, Diode Pulse PART No. PART No. FEATURES u The WOR designed ceilings g pattern. Occupanc u The low v sensor giv The Diversa occupancy sen SPECIFICATION WOSSDD1-P-VW Power Pack, 120/277, 20A, 2P, 24VAC power, Diode Pulse 54 PIR and ADI-Voice technol operating determine the presence of PP20-D P Inputs perform the control actions rela occupancy vacancy) is u 24 VAC o25% (orpulse u The Diversa occupancy sensors use PIR and ADI-Voice 57 technologies to determine the u Class 2TheLow Voltage WOS Series of Sourc sensors Features presence of people and perform u 60 Hz designed replace a low vol switch giving a 180 cover the control actions when u Use #18AWG wire u Recessed ceiling mounted occupancy sensor provides 360 PROGRAMMER occupancy (or vacancy) is The low voltage edition of adjustable swivel head to optimize the sensor area. Outputs gives the capability of oper detected. IR Handheld Remote Programmer controlling the WP-PP20-D u Diode Pulse: Each output u The dual-tech sensor utilizes ADI-Voice Technology, Pack and/or diodewhich pulse re u The WOR Series of sensors are of driving one Diode Pulse signal processing for accurate detection of human speech. designed to mount recessed on a Direct replacement for WR Power consumption ceilings giving a 360° coverage u A Self-adapting mode can be set to use both Passive Infrar u 9.5 mA Standard pattern. Detection Intelligence (ADI) Voice technologies to automati Approvals tendencies for continuous maximizing of energy savings. u The low voltage edition of this u FCC sensor gives the of Douglas Retrofit Ceiling Occupancy Sensor The Diversa occupancy sensors use capability Inputs WOSSDD1-P-VW u Smart Sensing allows for an immediate return to occupied PIR and ADI-Voice technologies 24 VAC operating andtocontrolling the 25% WP- Environment false off being determine the presence of people and triggered. Class 2diode Low Voltage Source PP20-D Power Pack and/or perform the control actions when u Indoors, stationary, non-vib PART No. FEATURES SPECIFICATION 60 Hz relays. occupancy (orpulse vacancy) is detected. u Can be programmed by on-board DIP switches and dials o UseWall #18AWG wire corrosive atmosphere and Ceiling Wall added convenience, especially during commissioning. The WOS Series of sensors are condensing humidity Inputs u The Diversa occupancy sensors Features SensorWORSDD1-N-N Switch u 24 VACdesigned Sensor u Ambient Operating Tempe Outputs use PIR and ADI-Voice WORXDD1-N-N o25%replace a low voltage wall switch giving a 180 coverage pattern Diode Pulse: Each output is capable 14°F to 140°F of (-10°C to 6 technologies to ceiling determine the occupancy u Class sensor 2 Low Voltage Source u Recessed mounted provides 360° coverage using an Operation driving one Diode Pulse relay. The low voltageedition of this sensor presence of people andhead perform u Storage Temperature: u 60 the Hz sensor adjustable swivel to optimize area. gives the capability of operating and Low voltage sensors are powered by 24VAC from either the WP-P the control actions when -14°F to 140°F (-25°C to 6 u Use #18AWG controlling wire the WP-PP20-D Power Power Consumption u The dual-tech sensor Technology, has advanced digital which 24VAC transformer. When in operation, the sensor will detect init Pack and/or diode pulse relays. occupancy (or vacancy) is utilizes 1 9.5 mA Standard 2 ADI-Voice 3 Outputs signal processing for accurate detection of human detected. oncespeech. motion is detected the internal contact will close. The ADI-Vo Direct replacement for WR-8501 u Diode Pulse: Each output is capable Approvals work alongside the PIR to detect occupancy. u WOR A Self-adapting modeare can be setoftodriving use both Infrared (PIR) & Accurate u The Series of sensors onePassive Diode Pulse relay. FCC designed to mount recessed(ADI) on a Voice technologies to automatically track occupancy Detection Intelligence Power consumption Environment ceilings giving a 360° coverage maximizing tendencies for continuous of energy savings. Indoors,% stationary, non-vibrating, nonu 9.5 mA Standard PASSIVE INFRAREDpattern. PIR UNTRASONIC DUAL TECHNOLOGY SENSOR TYPE SAVINGS and nonu Smart Sensing allows for an immediate return to occupied mode in the corrosive event ofatmosphere a Approvals condensing humidity u The voltage edition of this X 1 2 Ambient Operating Temperature: low false off being triggered. u FCC sensor gives The Diversa occupancy sensorsthe use capability Inputs of WOSSDD1-P-VW 14°F to 140°F (-10°C to 60°C) and ADI-Voice u technologies Can and be to programmed by25% on-board DIP switches and dials or an Unit for 40 24 VAC operating controlling the WPXPIR 1 IR 2Setting Environment Storage TheTemperature: Diversa occupancy sensor determine the presence of people and Class 2 Low Voltage Sourcecommissioning. added convenience, especially during PP20-D Power Pack and/or diode -14°F to 140°F (-25°C to 60°C) perform the control actions when u Indoors, stationary, non-vibrating, non 60 Hz PIR and ADI-Voice technologie relays. occupancy (orpulse vacancy) is detected. X X atmosphere and non- 2 40 corrosive WORSDD1-N-N WORXDD1-N-N Power Pack, 347, 20A, 1P, 24VAC power, Diode Pulse Technical Data LOCATION Bedroom Cafeteria Classroom Use #18AWG wire DIMENSIONS & MO determine the presence of peo condensing humidity 45-80 u Ambient Operating Temperature:1 u Unitthe attaches to mounting and perform control action are powered by 24VAC from either the WP-PP20-D Power Pack or a Diode Pulse: is capable 14°F to 140°F of (-10°C to 60°C) u Recessed ceiling mounted occupancy sensor provides 360° coverage using an Each output screws or it can be mounte driving Diode Pulse when (or vacancy) 24VAC transformer. When in one operation, therelay. sensor will detect initial PIR; occupancy Conference Room X Temperature: 1 motion 2 3using 20-60 The low voltage of this sensor X u Storage adjustable swivel head to optimize the sensor area.edition octagon box. gives the capability of operating and once motion is detected the internal contact will close. The ADI-Voice is then activated to detected. -14°F to 140°F (-25°C to 60°C) controlling the WP-PP20-D Power Power Consumption Hallway X to9.5detect 2 3 u The dual-tech sensor utilizes ADI-Voice Technology, has advanced digital work alongside the PIR occupancy. Pack and/or diodewhich pulse relays. mA Standard signal processing for accurate detection of human speech. The WOW Series of sensors a Features Closet/Storage Lecture Hall The WOS Series Operation of sensors are designed replace a low voltage wall switch giving a 180 coverage pattern Low voltage sensors X Direct replacement for WR-8501 XOutputs Approvals u A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate FCC Detection Intelligence (ADI) Voice technologies to automatically track Library X occupancy Environment tendencies for continuous maximizing of energy savings. Lobby X X 2 2 Occupancy Sensor Indoors, stationary, non-vibrating, non- and nonu Smart Sensing allows for an immediate return to occupied mode in the corrosive event ofatmosphere a condensing humidity falseOffice off being triggered. Private X X Ambient Operating Temperature: X 1 2 designed to surface mount on wall giving either a 90° or 130 www.DouglasLighti 3 coverage pattern. Mount in a standard gangWOR box. sensor will fit an u The voltage edition of this 2 The low5-50 box. It is very important tha sensor gives the capability ofen be attached at opposite 1 2 30-90 Inputs sensors use box. controlling the operating and PIR and ADI-Voice technologies to 24 VAC 25% Stall PP20-D Power Pack and/or di DIMENSIONS & MOUNTING determine the presence of people Operation Class Low Voltage Source pulse 2relays. Warehouse X 3 45-80 attaches to mounting ring with 60 Hz and orperform control actions Low voltage sensors are powered by 24VAC from either the WP-PP20-D Power Pack a u Unitthe screws or it can be mounted into an is when 24VAC transformer. When in operation, the sensor will detect initial motion using PIR; occupancy (or vacancy) Use #18AWG wire octagon box. u Use a 2-1/8” or more, dee once motion is detected the internal contact will close. The ADI-Voice is then activated to detected. box is less, use the spacer work alongside the PIR to detect occupancy. # Outputs The WOW Series of sensors are Occupancy Sensor www.DouglasLightingControls.com Diode Pulse: Each output is ca designed to surface mount on a driving up to four Diode Pulse wall giving either a 90° or 130° #14038700 Rev A 0-10V Dimming: Use to contro coverage pattern. 50 Ballasts. Connections are p Mount in a standard gangWOR box. sensor will fit an octagon 4 LED Drivers u The sensitive. 25mA of The low voltage edition of this box. It is very important that conduits sensor gives the capability of Aux Relay: SPDT Form-C conta be attached at opposite ends of the box. controlling the WPoperating and for 1A at 30VDC. PP20-D Power Pack and/or diode 14°F to 140°F (-10°C to 60°C) u Can be programmed by on-board DIP switches and dials or an IR Setting Unit for Rest Room Multi XStorage X TheTemperature: Diversa occupancy added convenience, especially during commissioning. -14°F to 140°F (-25°C to 60°C) 1 TM Retrofit Ceiling Occupancy Sensor Technical Data Specification Inputs Part No CCORSDD1-N-N CCORXDD1-N-N Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOR Séries of sensors are designed to mount recessed on a ceilings giving a 360° coverage pattern. The low voltage edition of this sensor gives the capability of operating and controlling the CCP-PP20-D Power Pack and/or diode pulse relays. 24 VAC +/- 25% Class 2 Low Voltage Source 60 Hz Use #18AWG wire Outputs Diode Pulse : Each output is capable of driving one Diode Pulse Relay Power consumption 9,5 mA Standard Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14°F to 140°F (-10°C to 60°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Features Recessed ceiling mounted occupancy sensor provides 360° coverage using an adjustable swivel head to optimize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. Operation 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com Low voltage sensors are powered by 24VAC from either the CCP-PP20-D Power Pack or a 24VAC transformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADI-Voice is then activated to work alongside the PIR to detect occupancy. 5 TM Retrofit Ceiling Occupancy Sensor Technical Data & Details Dimensions & Mounting Unit attaches to mounting ring with screws or it can be mounted into an octagon box. The CCOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. Use a 2-1/8” or more, deep box. If the box is less, use the spacer ring. Wiring Instructions The CCOR Series Trickle Current sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections Wiring to a Power Pack Wiring to a Relay Panel Sensor Settings (See page 60-61 for Sensor Setting description) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Vacancy Sensor 4.Smart Sensing 5. Automatic Timeout 6 TM Retrofit Ceiling Occupancy Sensor Details & Coverage Installation Installing in Smaller Room (Standard Lens) ffLocate the sensor near the entrance door wall to prevent it from viewing out into the hallway. ffThe lens can rotate, allowing the sensor to be pointed toward the area in front of the entrance door. ffPositioning the sensor in this manner ensures that an occupant moves across the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Standard Lens (S) ffOptimal usage is to detect small motions such as hand movements ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy 7 TM Retrofit Ceiling Occupancy Sensor Details & Coverage Extended Lens (X) ffOptimal usage is to detect small motions such as hand movements ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Installing in Larger Room (Extended Lens) ffPlace the sensor near the center of the room ceiling. Locate it so the approximate distance of 27ft in and over (A & B) or in dead center of room. ffTilt the lens to ai m the detection zone to the bottom of the door. (C) ffPositioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. * Application and Performance Specification Information Subject to Change without Notification 8 TM Retrofit Ceiling Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a 2-1/8” deep or more, octagonal junction box. Install by recessing the device into the octagon box; lining up the mounting holes and securing it using the screws provided. If too shallow, use the spacer ring is provided. CORSDD1-N-N Wiring The WOR Series Retrofit sensors are equipped with plug-in harness for easy installation. This harness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Enabled OFF Occupancy (Auto-ON) Vacancy (Manual ON) ON N/A N/A OFF N/A OFF Enabled OFF Manual Dips/Dials ON Inputs u 24 VAC o25% u Class 2 Low Voltage Source u 60 Hz u Use #18AWG wire SPECIFICATION Douglas Retrofit Ceiling Occupancy Sensor u The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. u The WOR Series of sensors are designed to mount recessed on a ceilings giving a 360° coverage pattern. u The low voltage edition of this sensor gives the capability of operating and controlling the WPPP20-D Power Pack and/or diode pulse relays. u Recessed ceiling mounted occupancy sensor provides 360° coverage using an adjustable swivel head to optimize the sensor area. u The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. u A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. u Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. u Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Disabled Approvals u FCC Power consumption u 9.5 mA Standard Outputs u Diode Pulse: Each output is capable of driving one Diode Pulse relay. N/A Environment u Indoors, stationary, non-vibrating, noncorrosive atmosphere and noncondensing humidity u Ambient Operating Temperature: 14°F to 140°F (-10°C to 60°C) u Storage Temperature: -14°F to 140°F (-25°C to 60°C) Auto or Manual ON Low voltage sensors are powered by 24VAC from either the WP-PP20-D Power Pack or a 24VAC transformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADI-Voice is then activated to work alongside the PIR to detect occupancy. Operation IR Handheld (CCIR-3110) Settings Input u The WOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. u Unit attaches to mounting ring with screws or it can be mounted into an octagon box. DIMENSIONS & MOUNTING 8 Disabled Detection LED 3 Manual Override Button 7 Motion Detection Sensivity 2 Not Used 6 High Technical Data OFF 1 Not Used CCOR*DD1-N-N FEATURES Normal Disabled Voice Detection PART No. DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. WORSDD1-N-N WORXDD1-N-N OFF 5 Features Default Enabled On Function DIP # 9 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com Off 4 White 24 Vac Bleu DO NOt USE Red Primary output pole Red/White Not Used Orange Not Used Yellow/Black Not Used Yellow Not Used Yellow/White Not Used Violet(+) Not Used Grey (-) Not Used 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 TM Low Voltage Ceiling Occupancy Sensor Technical Data Specification Inputs 24 VAC +/-25% Class 2 Low Voltage Source 60Hz Use #18WG wire Part No CCORSDD2-N-N CCORSDD2-R-N CCORSDD2-DPR-L CCORXDD2-PR-N CCORXDD2-DPR-L Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOR Series of sensors are designed to mount recessed in to a ceiling space providing a 360° coverage pattern. The low voltage edition of this sensor gives the capability of operating and controlling the CCPPP20-D Power Pack and/or diode pulse relays. Outputs Diode Pulse : Each output is capable of driving up to four Diode Pulse relays. 0-10V Dimming : Use to control up to 50 Ballasts. Connections are polarity sensitive. LED drivers can connect up to 25mA Aux Relay : SPDT Form-C contact rated for 1A at 30VDC Power consumption 9.5 mA Standard 14.0 mA with Auxiliary Relay Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14°F to 140°F (-10°C to 60°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40°C/F. Features Recessed ceiling mounted occupancy sensor provides 360° coverage using an adjustable swivel head to optimize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. The photo sensor option is available to provide a 0-10VDC dimming ballast/LED* Drivers output for Daylight Harvesting. * LED drivers up to 25mA, please contact driver manufacturer for currents 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. 10 TM Low Voltage Ceiling Occupancy Sensor Technical Data & Details Operation Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. Dimensions & Mounting Unit attaches to mounting ring with screws or it can be mounted into an octagon box. The CCOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. Use a 2-1/8” or more, deep box. If the box is less, use the spacer ring. Wiring Instructions The CCOR Series Line Voltage sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCP-PP20-D 11 TM Low Voltage Ceiling Occupancy Sensor Technical Data & Details Sensor Settings (See page 60-61 for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Vacancy Sensor 6. Photo Sensing (-P) 7. Daylight Harvest Dimming (0-10V Output) (-D) 8. Multi-Level Switching (2-Pole w/o Photo Sensing option) 9. Multi-Level Photo Sensing (2-Pole w/ Photo Option) 10. Sensor Link 12 TM Low Voltage Ceiling Occupancy Sensor Details & Coverage Installation Installing in Smaller Room (Standard Lens) ffLocate the sensor near the entrance door wall to prevent it from viewing out into the hallway. ffThe lens can rotate, allowing the sensor to be pointed toward the area in front of the entrance door. ffPositioning the sensor in this manner ensures that an occupant moves across the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Standard Lens (S) ffOptimal usage is to detect small motions such as hand movements ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Extended Lens (X) ffOptimal usage is to detect small motions such as walking ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy 13 TM Low Voltage Ceiling Occupancy Sensor Details & Coverage Installing in Larger Room (Extended Lens) ffPlace the sensor near the center of the room ceiling. Locate it so the approximate distance of 27ft in and over (A & B) or in dead center of room. ffTilt the lens to aim the detection zone to the bottom of the door. (C) ffPositioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. Installation & Wiring Directions Installation Mounting of the device requires a 2-1/8” deep or more, octagonal junction box. Install by recessing the device into the octagon box; lining up the mounting holes and securing it using the screws provided. If too shallow, use the spacer ring is provided. Wiring The CCOR Series Low Voltage sensors are equipped with plug-in harness for easy installation. This harness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. 14 TM Low Voltage Ceiling Occupancy Sensor Installation DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOR - - - - ‘-N’DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Not Used N/A N/A OFF 6 Not Used N/A N/A OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON CCOR - - - - ‘-P’DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON CCOR - - - - ‘-DPR’DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Photocell Inhibit** Photocell Disabled & Fixed Dim Level Photocell Enabled + Auto Dim Level OFF 6 Photocell Control* Inhibit 2nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON 15 TM Line Voltage Ceiling Occupancy Sensor Technical Data Specification Power 120/277 VAC 60Hz Contact Ratings Part No CCORBIU2-P-N PIR Only CCORSDU1-P-N CCORSDU2-P-N CCORXDU2-P-L Desription The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOR Series of sensors are designed to mount recessed in to a ceiling space providing a 360° coverage pattern. Has an adjustable tilting lens to prevent detection outside monitored space. 120 VAC-800W 277 VAC-1200W Power consumption 5,7 mA Approvals Certified to UL 508, UL244A, CSA C22.2 #14 Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 32°F to 104°F (0°C to 40°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40°C/F. Indoor use only. Features Recessed ceiling mounted occupancy sensor provides 360° coverage using an adjustable swivel head to optimize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. Operation 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. 16 TM Line Voltage Ceiling Occupancy Sensor Technical Data & Details Dimensions & Mounting Unit attaches to mounting ring with screws or it can be mounted into an octagon box. The CCOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. Use a 2-1/8” or more, deep box. If the box is less, use the spacer ring. Wiring Instructions The CCOR Series Line Voltage sensors are equipped with #14 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCOR**U*-*-* CCOR**U2*-*-* Sensor Settings (See page 60-61 for Sensor Setting description) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4.Smart Sensing 5. Photo Sensing (-P) 6.Multi-Level Photo Sensing (2-Pole w/ Photo Option) 17 TM Line Voltage Ceiling Occupancy Sensor Details & Coverage Installation Installing in Smaller Room (Standard Lens) ffLocate the sensor near the entrance door wall to prevent it from viewing out into the hallway. ffThe lens can rotate, allowing the sensor to be pointed toward the area in front of the entrance door. ffPositioning the sensor in this manner ensures that an occupant moves across the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Standard Lens (S) ffOptimal usage is to detect small motions such as hand movements ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Extended Lens (X) ffOptimal usage is to detect small motions such as walking ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy 18 TM Line Voltage Ceiling Occupancy Sensor Details & Coverage Hi-Bay Lens (B) ffOptimal usage is to detect small motions such as walking ffDesigned for a mounting height up to 40Ft ffPIR only Installing in Larger Room (Extended Lens) ffPlace the sensor near the center of the room ceiling. Locate it so the approximate distance of 27ft in and over (A & B) or in dead center of room. ffTilt the lens to ai m the detection zone to the bottom of the door. (C) ffPositioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. * Application and Performance Specification Information Subject to Change without Notification 19 TM Line Voltage Ceiling Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a 2-1/8” deep or more, octagonal junction box. Install by recessing the device into the octagon box; lining up the mounting holes and securing it using the screws provided. If too shallow, use the spacer ring is provided. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The CCOR Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wirenuts to connect the wires to the incoming load terminations; for installation with fieldinstalled conductors of 60ºC minimum rating. CCOR**U*-*-* CCOR**U2*-*-* 20 TM Line Voltage Ceiling Occupancy Sensor Installation DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOR - - - - ‘-N’DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Not Used N/A N/A OFF 6 Not Used N/A N/A OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON CCOR - - - - ‘-P’DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5* Not Used Disabled Enabled OFF 6* Not Used Inhibit 2 Pole Only Inhibit Both Pole OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON nd *Available in 2-Pole models (-2) only 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 21 TM Line Voltage Ceiling Occupancy Sensor, 347VAC Technical Data Specification Power 347-1 VAC 60Hz Contact Ratings Part No CCORSD31-P-N CCORXD32-P-N CCORSD32-P-N Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOR Series of sensors are designed to mount recessed in to a ceiling space providing a 360° coverage pattern. Has an adjustable tilting lens to prevent detection outside monitored space. 347 VAC-1200W Power consumption 5,7 mA Approvals Certified to UL 508, UL244A, CSA C22.2 #14 Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 32°F to 104°F (0°C to 40°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40°C/F. Indoor use only. Features Recessed ceiling mounted occupancy sensor provides 360° coverage using an adjustable swivel head to optimize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. Operation 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. 22 TM Line Voltage Ceiling Occupancy Sensor, 347VAC Technical Data & Details Dimensions & Mounting Unit attaches to mounting ring with screws or it can be mounted into an octagon box. The CCOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. Use a 2-1/8” or more, deep box. If the box is less, use the spacer ring. Wiring Instructions The CCOR Series Line Voltage sensors are equipped with #14 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCOR**3*-*-* CCOR**32*-*-* Sensor Settings (See page 60-61 for Sensor Setting description) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4.Smart Sensing 5. Photo Sensing (-P) 6.Multi-Level Photo Sensing (2-Pole w/ Photo Option) 23 TM Line Voltage Ceiling Occupancy Sensor, 347VAC Details & Coverage Installation Installing in Smaller Room (Standard Lens) ffLocate the sensor near the entrance door wall to prevent it from viewing out into the hallway. ffThe lens can rotate, allowing the sensor to be pointed toward the area in front of the entrance door. ffPositioning the sensor in this manner ensures that an occupant moves across the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Standard Lens (S) ffOptimal usage is to detect small motions such as hand movements ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Installing in a Larger Room (Extended Lens) ffPlace the sensor near the center of the room ceiling. Locate it so the approximate distance of 27ft in and over (A&B) or in dead center of room. ffTilt the lens to aim the detection zone of the bottom of the door (C). ffPositioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. 24 TM Line Voltage Ceiling Occupancy Sensor, 347VAC Details & Coverage Extended Lens (X) ffOptimal usage is to detect small motions such as walking ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Hi-Bay Lens (B) ffOptimal usage is to detect small motions such as walking ffDesigned for a mounting height up to 40Ft ffPIR only 25 TM Line Voltage Ceiling Occupancy Sensor, 347VAC Installation Installation & Wiring Directions Installation Mounting of the device requires a 2-1/8” deep or more, octagonal junction box. Install by recessing the device into the octagon box; lining up the mounting holes and securing it using the screws provided. If too shallow, use the spacer ring is provided. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The CCOR Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wirenuts to connect the wires to the incoming load terminations; for installation with fieldinstalled conductors of 60ºC minimum rating. CCOR**3*-*-* CCOR**32*-*-* DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOR - - - - ‘-P’- 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Photocell Inhibit** Disabled Enabled OFF 6 Photocell Control Inhibit 2 Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON nd *Available in 2-Pole models (-2) only 26 TM Retrofit Wall Switch Occupancy Sensor Technical Data Part No CCOSSDD1-P-VW Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOS Series of sensors are designed replace a low voltage wall switch giving a 180° coverage pattern The low voltage edition of this sensor gives the capability of operating and controlling the CCP-PP20-D Power Pack and/or diode pulse relays. Direct replacement for WR-8501 Specification Inputs 24 VAC +/-25% Class 2 Low Voltage Source 60Hz Use #18WG wire Outputs Diode Pulse : Each output is capable of driving up to one Diode Pulse relays. Power consumption 9.5 mA Standard Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14°F to 140°F (-10°C to 60°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40°C/F. Features Wall Switch occupancy sensor provides 180° coverage to maximize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 27 TM Retrofit Wall Switch Occupancy Sensor Technical Data & Details Operation Line voltage sensors are powered by 24VAC from either the CCP-PP20-D Power Pack or a 24VAC tranformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADIVoice is then activated to work alongside the PIR to detect occupancy. Dimensions & Mounting Mount in a standard gang box. Wiring Instructions The CCOS Series Low Voltage sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCP-PP20-D 28 TM Retrofit Wall Switch Occupancy Sensor Details Sensors Settings (See page 60-61 for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Vacancy Sensor 6. Photo Sensing (-P) 29 TM Retrofit Wall Switch Occupancy Sensor Details & Coverage Installation Mount the CCOSSDD1-P-VW sensor on the wall about 4' above floor level near the midline of the room so its PIR detection zones cover the room area and any obstructions are within range of the ADI-Voice detector. There should be no obstructions between the sensor and the room entrance. The ensures that the sensor's PIR lens will be activated when a person enters the room, wich will subsequently trigger the ADI-Voice. Installing in Offices ffSensor effective in obstructed spaces ffADI-Voice re-activation and Smart Sense prevents lights out condition Typical Office Installing in Washrooms ffSensor effective in partitioned spaces ffADI-Voice re-activation and Smart Sense prevents lignts out condition Standard Lens (S) ffOptimal usage is to detect small motions such as hand movements Typical WashRooms ffDesigned for a mounting height of 7-15ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Top View Side View *Application and Performance Specification Information Subject to Change without Notification 30 TM Retrofit Wall Switch Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a standard box. Install by recessing the device into the standard gang box; lining up the mounting hole and securing it using the screws provided. Wiring The CCOSSDD1-P-VW Retrofit sensors are equipped with plug-in harness for easy installation. This hardness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOSSDD1-P-VW DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) OFF 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2 Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON nd 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 31 TM Low Voltage Wall Switch Occupancy Sensor Technical Data Part No CCOSSDD2-P-VW CCOSSDD2-DPR-VW Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOS Series of sensors are designed replace a low voltage wall switch giving a 180° coverage pattern. The low voltage edition of this sensor gives the capability of operating and controlling the WPPP20-D Power Pack and/or diode pulse relays. *Plate not included Specification Inputs 24 VAC +/-25% Class 2 Low Voltage Source 60 Hz Use #18AWG wire Outputs Diode Pulse: Each output is capable of driving up to four Diode Pulse relays. 0-10V Dimming: Use to control up to 50 Ballasts, or 25mA sync of LED driver. Connections are polarity sensitive. Aux Relay: SPDT Form-C contact rated for 1A at 30VDC Power consumption 9.5 mA Standard 14.0 mA with Auxiliary Relay Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14°F to 140°F (-10°C to 60°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40°C/F. Features Wall Switch occupancy sensor provides 180° coverage to maximize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. The photo sensor option is available to provide a 0-10VDC dimming ballast or 25mA sync for LED drivers output for Daylight Harvesting. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. 32 TM Low Voltage Wall Switch Occupancy Sensor Technical Data & Details Operation Low voltage sensors are powered by 24VAC from either the CCP-PP20-D Power Pack or a 24VAC transformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADIVoice is then activated to work alongside the PIR to detect occupancy. Dimensions & Mounting Mount in a standard gang box. Wiring Instructions The CCOS Series Low Voltage sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCP-PP20-D 33 TM Low Voltage Wall Switch Occupancy Sensor Details Sensors Settings (See page 60-61 for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Vacancy Sensor 6. Photo Sensing (-P) 7. Daylight Harvest Dimming (0-10V Output) (-D) 8. Multi-Level Switching (2-Pole w/o Photo Option) 9. Multi-Level Photo Sensing (2-Pole w/Photo Option) 10. Sensor Link 34 TM Low Voltage Wall Switch Occupancy Sensor Details and Coverage Installation Mount the CCOS Series sensor on the wall about 4' above floor level near the midline of the room so its PIR detection zones cover the room area and any obstructions are within range of the ADI-Voice detector. There should be no obstructions between the sensor and the room entrance. The ensures that the sensor's PIR lens will be activated when a person enters the room, wich will subsequently trigger the ADI-Voice. Installing in Offices ffSensor effective in obstructed spaces ffADI-Voice re-activation and Smart Sense prevents lights out condition Typical Office Installing in Washrooms ffSensor effective in partitioned spaces ffADI-Voice re-activation and Smart Sense prevents lights out condition Standard Lens (S) ffOptimal usage is to detect small motions such as hand movements Typical WashRooms ffDesigned for a mounting height of 4ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Top View Side View 35 TM Low Voltage Wall Switch Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a standard gang box. Install by recessing the device into the standard gang box; lining up the mounting holes and securing it using the screws provided. Wiring The CCOS Series Low Voltage sensors are equipped with plug-in harness for easy installation. This harness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOS - - - - ‘-P’DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) OFF 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2 Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON nd 36 TM Low Voltage Wall Switch Occupancy Sensor Installation DIP Switches CCOS - - - - ‘-DPR’DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) OF 5* Photocell Inhibit** Photocell Disabled & Fixed Din Level Photocell Enabled & Auto Dim Level OFF 6* Photocell Control Inhibit 2nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 37 TM Low Voltage Wall Mount Occupancy Sensor Technical Data Part No CCOWCDD2-R-N CCOWLDD2-R-N CCOWCDD2-DPR-N Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOW Series of sensors are designed to surface mount on a wall giving either a 90° or 130° coverage pattern. The low voltage edition of this sensor gives the capability of operating and controlling the WP-PP20-D Power Pack and/or diode pulse relays. Specification Inputs 24 VAC +/-25% Class 2 Low Voltage Source 60 Hz Use #18AWG wire Outputs Diode Pulse: Each output is capable of driving up to four Diode Pulse relays. 0-10V Dimming: Use to control up to 50 Ballasts, or 25mA sync of LED driver. Aux Relay: SPDT Form-C contact rated for 1A at 30VDC Power consumption 9.5 mA Standard 14.0 mA with Auxiliary Relay Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14°F to 140°F (-10°C to 60°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Features Wall mount occupancy sensor provides 90° or 130° coverage. Has the ability to rotate in both the horizontal and vertical axis to optimize the sensing area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. The photo sensor option is available to provide a 0-10VDC dimming ballast or 25mA sync for LED drivers output for Daylight Harvesting. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. 38 TM Low Voltage Wall Mount Occupancy Sensor Technical Data & Details Operation Low voltage sensors are powered by 24VAC from either the CCP-PP20-D Power Pack or a 24VAC transformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADIVoice is then activated to work alongside the PIR to detect occupancy. Dimensions & Mounting Mount in a octagon box. Wall Mount Ceiling Mount Wiring Instructions The CCOW Series Low Voltage sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCP-PP20-D 39 TM Low Voltage Wall Mount Occupancy Sensor Details Sensors Settings (See page 60-61 for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Vacancy Sensor 6. Photo Sensing (-P) 7. Daylight Harvest Dimming (0-10V Output) (-D) 8. Multi-Level Switching (2-Pole w/o Photo Option) 9. Multi-Level Photo Sensing (2-Pole w/Photo Option) 10. Sensor Link 40 TM Low Voltage Wall Mount Occupancy Sensor Details & Coverage Installation Installing in Smaller Room (Corner Lens) ffLocate the sensor in the corner, along the entrance door to prevent it from viewing out into the hallway. ffThe sensor can be rotated, allowing it to be pointed along the entrance door and slighly downwards. ffPositioning the sensor in this manner ensures that an occupant move accross the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Typical Enclosed Office Corner Lens ffOptimal usage is to detect small motions such as hand movements. ffDesigned for a mounting height of up to 7-15ft. ffADI-Voice can detect around corners that PIR cannot to maintain occupancy. Installing in Larger Room (Large Area Lens) ffPlace the sensor near the center of the wall that is adjacent to the entrance. ffThe sensor can be rotated, allowing it to be pointed along the entrance door and slighly downwards. ffPositioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. Typical Classroom Large Area Lens ffOptimal usage is to detect large motions such as walking. ffDesigned for a mounting height of 7-15ft. ffADI-Voice can detect around corners that PIR cannot to maintain occupancy. 41 TM Low Voltage Wall Mount Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a 2 1/8" deep, octogonal junction box. Install by recessing the device into the o ctogonal box; lining up the mounting holes and securing it using the screws provided. Wiring The CCOW Series Low Voltage sensors are equipped with plug-in harness for easy installation. This harness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOW - - - - ‘R-N’ DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) OFF 5 Not Used N/A N/A OFF 6 Not Used N/A N/A OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 42 TM Line Voltage Wall Switch Occupancy Sensor Technical Data Part No CCOSSDU1-P-VW CCOSSDU2-P-VW CCVSSDU2-P-VW Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOS Series of sensors are designed replace a low voltage wall switch giving a 180° coverage pattern *Plate not included Specification Power 120/277 VAC 60Hz Contact Ratings 120 VAC - 800W 277 VAC - 1200W Power consumption 400 mA Approvals Certified to UL 508, UL244A, CSA C22.2 #14 Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 32°F to 104°F (0°C to 40°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Features Wall Switch occupancy sensor provides 180° coverage to maximize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 43 TM Line Voltage Wall Switch Occupancy Sensor Technical Data & Details Operation Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. Dimensions & Mounting Mount in a standard gang box. Wiring Instructions The CCOS Series Line Voltage sensors are equipped with #14 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCOS**U*-*-* CCOS**U2*-*-* 44 TM Line Voltage Wall Switch Occupancy Sensor Details Sensors Settings (See page 60-61 for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 6. Photo Sensing (-P) 9. Multi-Level Photo Sensing (2-Pole w/Photo Option) 45 TM Line Voltage Wall Switch Occupancy Sensor Details & Coverage Installation Mount the CCOS Series sensor on the wall about 4' above floor level near the midline of the room so its PIR detection zones cover the room area and any obstructions are within range of the ADI-Voice detector. There should be no obstructions between the sensor and the room entrance. The ensures that the sensor's PIR lens will be activated when a person enters the room, wich will subsequently trigger the ADI-Voice. Installing in Offices ffSensor effective in obstructed spaces ffADI-Voice re-activation and Smart Sense prevents lights out condition Typical Office Installing in Washrooms ffSensor effective in partitioned spaces ffADI-Voice re-activation and Smart Sense prevents lignts out condition Standard Lens (S) ffOptimal usage is to detect small motions such as hand movements Typical WashRooms ffDesigned for a mounting height of 4ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Top View Side View 46 TM Line Voltage Wall Switch Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a standard gang box. Install by recessing the device into the standard gang box; lining up the mounting holes and securing it using the screws provided. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The CCOS Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wirenuts to connect the wires to the incoming load terminations; for installation with fieldinstalled conductors of 60ºC minimum rating. CCOS**U*-*-* CCOS**U2*-*-* DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOS - - - - ‘-P’- 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON *Available in 2-Pole models (-2) only 47 TM Line Voltage Wall Switch Occupancy Sensor, 347V Technical Data Part No CCOSSD31-P-VW CCOSSD32-P-VW Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOS Series of sensors are designed replace a low voltage wall switch giving a 180° coverage pattern. 347 VAC. *Plate not included Specification Power 347 VAC 60Hz Contact Ratings 347 VAC - 1500W Power consumption 400 mA Approvals Certified to UL 508, UL244A, CSA C22.2 #14 Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 32°F to 104°F (0°C to 40°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40°C/F. Indoor use only. Features Wall Switch occupancy sensor provides 180° coverage to maximize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 48 TM Line Voltage Wall Switch Occupancy Sensor, 347V Technical Data & Details Operation Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. Dimensions & Mounting Mount in a standard gang box. Wiring Instructions The CCOS Series Line Voltage sensors are equipped with #14 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCOSSD3*-*-* CCOSSD32*-*-* 49 TM Line Voltage Wall Switch Occupancy Sensor, 347V Details Sensors Settings (See page 60-61 for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 6. Photo Sensing (-P) 9. Multi-Level Photo Sensing (2-Pole w/Photo Option) 50 TM Line Voltage Wall Switch Occupancy Sensor, 347V Details & Coverage Installation Mount the CCOS Series sensor on the wall about 4' above floor level near the midline of the room so its PIR detection zones cover the room area and any obstructions are within range of the ADI-Voice detector. There should be no obstructions between the sensor and the room entrance. The ensures that the sensor's PIR lens will be activated when a person enters the room, wich will subsequently trigger the ADI-Voice. Installing in Offices ffSensor effective in obstructed spaces ffVoice sound re-activation prevents lights out condition Typical Office Installing in Washrooms ffSensor effective in partitioned spaces ffVoice sound re-activation prevents lignts out condition Standard Lens (S) ffOptimal usage is to detect small motions such as hand movements Typical WashRooms ffDesigned for a mounting height of 4ft ffADI-Voice can detect around corners that PIR cannot to maintain occupancy Top View Side View 51 TM Line Voltage Wall Switch Occupancy Sensor, 347V Installation Installation & Wiring Directions Installation Mounting of the device requires a standard gang box. Install by recessing the device into the standard gang box; lining up the mounting holes and securing it using the screws provided. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The CCOS Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wirenuts to connect the wires to the incoming load terminations; for installation with fieldinstalled conductors of 60ºC minimum rating. CCOSSD3*-*-* CCOSSD32*-*-* DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOS - - - - ‘-P’- 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON *Available in 2-Pole models (-2) only 52 TM 1-Pole Power Pack (120-277-1) Technical Data Part No CCP-PP20-D 1-Pole 120/277VAC Features Designed for use with Diversa occupancy sensors and Diode Pulse relays. Single pole 120/277 VAC Specification Load Voltage 120/277 VAC 60 Hz Switched Load 120/277 VAC See Table for contact rating Use #14 AWG Wire Inputs Diode Pulse #14AWG wire Secondary Power Source 24 VAC, 150 mA #14AWG wire Approvals Certified to CAN/CSA Std. C22.2 No. 14 Conforms to UL 508 Standard Title 24 FCC Plenum Rated Class 2 Rating Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14°F to 140°F (-10°C to 60°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 53 TM 1-Pole Power Pack (120-277-1) Technical Data & Details Operation The CCP-PP20-D Power Pack work in conjunction with the Diversa Low Voltage Sensors by providing power to the sensors and receiving on/off commands from the sensor. Contact Load Rating Voltage General Tungsten Standard Ballast Electronic Ballast 120V 20A 20A 20A 16A 277V 20A 20A 20A 16A All Power Packs provide a 24 VAC secondary source for use with the Low Voltage Diversa Sensors and other Diode Pulse devices. All switches or loads required to be supported by the sensor must be included in the loading capacity of the Power Pack. Maximum Load Per Input Voltage Max# of linked sensors 24VAC 12 Typical Low Voltage Loads Device Part# Ceiling Mounted Sensor CCOR/CCVR Wall Switch Sensor CCOS/CCVS Wall Mount Sensor CCOW/CCVW Diode Pulse Switch WR-8601 Current (mA) 9,5mA Standard 14,0mA w/Aux Relay 4mA Wiring Directions Wiring Terminating wire shall be a minimum of #22 AWG for control power connections and shall be suitably sized to handle the load ratings below. Electrical Connections CCP-PP20-D 54 TM 1-Pole Power Pack (120-277-1) Details Dimensions & Mounting The power pack shall be mounted inside an electrical junction box or panel with a ½” threaded nipple. CCP-PP20-D * Application and Performance Specification Information Subject to Change without Notification 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 55 TM 1-Pole Power Pack (347-1) Technical Data Part No CCP-PP20-347-D 1-Pole 347-1 VAC Features Designed for use with Diversa occupancy sensors and Diode Pulse relays. Single pole 347 VAC Specification Load Voltage 347 VAC 60 Hz Switched Load 347 VAC See Table for contact rating Use #14 AWG Wire Inputs Diode Pulse #14AWG wire Secondary Power Source 24 VAC, 150 mA #14AWG wire Approvals Certified to CAN/CSA Std. C22.2 No. 14 Conforms to UL 508 Standard Title 24 FCC Plenum Rated Class 2 Rating Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14°F to 140°F (-10°C to 60°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 56 TM 1-Pole Power Pack (347-1) Technical Data & Details Operation The CCP-PP20-347-D Power Pack work in conjunction with the Diversa Low Voltage Sensors by providing power to the sensors and receiving on/off commands from the sensor. Contact Load Rating Voltage General Tungsten Standard Ballast Electronic Ballast 347V 20A 20A 20A 16A All Power Packs provide a 24 VAC secondary source for use with the Low Voltage Diversa Sensors and other Diode Pulse devices. All switches or loads required to be supported by the sensor must be included in the loading capacity of the Power Pack. Maximum Load Per Input Voltage Max# of linked sensors 24VAC 12 Typical Low Voltage Loads Device Part# Ceiling Mounted Sensor CCOR/CCVR Wall Switch Sensor CCOS/CCVS Wall Mount Sensor CCOW/CCVW Diode Pulse Switch WR-8601 Current (mA) 9,5mA Standard 14,0mA w/Aux Relay 4mA Installation & Wiring Directions Installation The power pack shall be mounted inside an electrical junction box or panel with a ½” threaded nipple. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The power packs are equipped with #14 AWG stranded leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. For installation with field-installed conductors of 60ºC minimum rating. 57 TM 1-Pole Power Pack (347-1) Details Electrical Connections CCP-PP20-347-D Dimensions & Mounting The power pack shall be mounted inside an electrical junction box or panel with a ½” threaded nipple. CCP-PP20-347-D * Application and Performance Specification Information Subject to Change without Notification 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 58 TM 2-Pole Power Pack (120-277-1) Technical Data Part No CCP-PP20-2P-D 2-Pole 120/277VAC Features Designed for use with Diversa occupancy sensors and Diode Pulse relays. 2 pole 120/277 Specification Load Voltage 120/277 VAC 60 Hz Switched Load 120/277 VAC 2-Pole Independent Switching See Table for contact rating Use #14 AWG Wire Inputs Diode Pulse #18AWG wire Output Power Source 24 VAC, 150 mA #14AWG wire Approvals Certified to CAN/CSA Std. C22.2 No. 14 Conforms to UL 508 Standard FCC Title 24 Plenum Rated Class 2 Rating Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14°F to 140°F (-10°C to 60°C) Storage Temperature : -14°F to 140°F (-25°C to 60°C) 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 59 TM 2-Pole Power Pack (120-277-1) Technical Data & Details Operation The CCP-PP20-2P-D Power Pack work in conjunction with the Diversa Low Voltage Sensors by providing power to the sensors and receiving on/off commands from the sensor. Contact Load Rating Voltage General Tungsten Standard Ballast Electronic Ballast 120V 20A 20A 20A 16A 277V 20A 20A 20A 16A All Power Packs provide a 24 VAC secondary source for use with the Low Voltage Diversa Sensors and other Diode Pulse devices. All switches or loads required to be supported by the sensor must be included in the loading capacity of the Power Pack. Maximum Load Per Input Voltage Max# of linked sensors 24V 12 Typical Low Voltage Loads Device Part# Ceiling Mounted Sensor CCOR/CCVR Wall Switch Sensor CCOS/CCVS Wall Mount Sensor CCOW/CCVW Diode Pulse Switch WR-8601 Current (mA) 9,5mA Standard 14,0mA w/Aux Relay 4mA Installation & Wiring Directions Installation The power pack shall be mounted inside an electrical junction box or panel with a ½” threaded nipple. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The power packs are equipped with #14 AWG stranded leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. For installation with field-installed conductors of 60ºC minimum rating. 60 TM 2-Pole Power Pack (120-277-1) Details Electrical Connections CCP-PP20-2P-D Dimensions & Mounting The power pack shall be mounted inside an electrical junction box or panel with a ½” threaded nipple. CCP-PP20-D * Application and Performance Specification Information Subject to Change without Notification 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 61 TM Sensor Settings Sensor Settings 1-Programming - IR / Manual Setting Programming can be done either with the DIP switches and dials on- board the device or with the CC IR-3110 Setting Unit. For more details and additional options please see the “CC IR-3110 Manual” 2-Detection (Dual or PIR Only) When in operation, the sensor will detect initial motion using Passive Infrared; once motion is detected the ADI-Voice is then is activated to work alongside the PIR to maintain occupancy. The ADI-Voice can be disabled on any dual tech sensors. 3-Automatic Timeout By setting the timeout dial to maximum, the sensor will be put into automatic mode which will adjust the time out automatically to maximize energy savings and occupant comfort. 4-Smart Sensing When vacancy occurs, sensitivity of the ADI-Voice technology transitions from maximum to zero over an adaptively determined time period, based on occupancy tendencies. During this period, ADIVoice can turn the lights back on immediately, even with no line-of-sight to the sensor, assuring the best combination of user convenience and energy savings. Energy consumption due to false triggers is minimized by the automatic walk-through mode. This feature turns the lights off after 3 minutes if no occupancy detection occurs in the first 30 seconds after initial turn on. 5-Vacancy Sensor The low voltage sensor can be selected as a vacancy (Off only) sensor. This provides additional energy savings by forcing the user to turn the lights on manually. The low voltage sensor has a builtin override input; allowing for the sensor to be operated as a vacancy sensor. For two pole sensors, it provides multi-level control capability. 6- Photo Sensing (-P) When enabled, occupancy alone will not trigger the output state to on. If occupancy is detected AND there is a deficiency of natural light, the output is triggered on. An increase in natural light will not force the lights off but as the ambient light level drops the lights will turn on automatically. 7- Daylight Harvest Dimming (0-10V Output) (-D) The 0-10V output can operate up to 50 ballasts/25mA of LED Drivers. This output can be used for either a fixed tuned lighting level or in a full range daylight harvesting mode. When set to a fixed dim level, the dial can be used to raise or lower the light level. When set for photo dimming the dial is used to select the maintained light level 62 TM Sensor Settings 8-Multi-Level Switching (2-Pole w/o Photo Sensing option) A switch on the sensor link can be used to either trigger both poles simultaneously or step through a multi-level sequence as described in the manual. 9- Multi-Level Photo Sensing (2-Pole w/ Photo Option) Photo sensing on a 2-pole sensor can be configured to either restrict both poles or the secondary pole only; if set to “Secondary Pole Only”, the primary pole will trigger based on occupancy, regardless of the photo setting.. 10-Sensor Link The low voltage sensor is equipped with a connection which facilitates communication between sensors. The sensor link (orange wire) allows multiple sensors to coordinate their signals and act together as a cohesive zone. This connection provides additional control functions as described below. ffDiode Pulse: When a diode switch is connected to the sensor link it provides manual control. This can be used to toggle the lights ON/OFF. For two pole sensors, it can provide multi-level sequencing. ffMaintained AC: If a maintained AC signal is applied to the sensor link, the sensors will be in an override mode. By default the sensor will turn the lights ON when disabled by this override. This is settable via the IR setting unit. 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com 63 1 Year Limited Warranty Cristal Controls is committed to achieving the highest standards of quality for every lighting control and energy management product and system it makes. As such, it warrants to the original user that its products will be free from defects in materials and workmanship for a period of one year following the date Cristal Controls ships the product. If any Cristal Controls product is found to be defective in material or workmanship during the applicable warranty period, Cristal Controls’ liability shall be to repair or replace or refund the purchase price, at Cristal Controls’ discretion. Cristal Controls’ shall not be held liable for any costs or expenses, whether direct or indirect, associated with the installation, removal or re-installation of any defective product. Cristal Controls’ limited warranty shall not be effective unless there has been compliance with all installation and operating instructions furnished by Cristal Controls, or if the products have been modified or altered without the written consent of Cristal Controls, or if such products have been subject to accident, misuse, mishandling, tampering, negligence, or improper maintenance. Any warranty claim must be submitted to Cristal Controls in writing within the stated warranty period. Cristal Controls’ limited warranty is made in lieu of, and Cristal Controls disclaims all other warranties, whether expressed or implied, including, but not limited to, any implied warranty of the products. Cristal Controls shall under no circumstances be liable for any direct, indirect, accidental, special, or consequential damage (including but not limited to, loss of profits, revenues, or business opportunities) or damage or injury to persons or property in any way related to the manufacture or the use of its products. The exclusion applies regardless of whether such damages are sought based on breach of warranty, breach of contract, negligence, strict liability in tort, or any other legal theory, even if Cristal Controls was notified of the possibility of such damages. By purchasing Cristal Controls products, the purchaser agrees to the terms and conditions of this limited warranty. Solutions énergétiques éclairées Smart Energy Solutions 1 Year Limited Warranty 2025, rue Lavoisier, # 135 Québec (Québec) G1N 4L6 T. 418 681-9590 • 1 800 681-9590 F. 418 681-7393 info@cristalcontrols.com cristalcontrols.com