AC/DC External type series (I.T.E Grade) : 10 ~ 350W.
AC/DC External type series (Medical Grade) : 10 ~ 350W
Battery chargers (Li-ion, Li-polymer, Ni_MH / Ni_Cd, Sealed Lead Acid )
LED drivers
POE.
Changing
world
History
History
History
Company History
Company History
Company History
2010. 03
2010. 032012. 02
2009. 12
2009. 122011. 08
2009. 01
2009. 012011. 03
2008. 112011. 01
2008. 112010. 07
2010. 04
2007. 04
2010. 01
2007. 04
2006. 02
2009. 01
2006. 02
2005. 11
2008. 11
2005. 11
2005. 05
2008. 11
2005. 052008. 04
2004. 01
2004. 012005. 08
2003. 01
2003. 012005. 05
2002. 11
2004. 01
2002. 112003. 01
2001. 05
2001. 05
2000. 082002. 11
2000. 082001. 05
2000. 02
2000. 02
1999. 01
1999. 012000. 08
1999. 03
1999. 032000. 02
1999. 01
1999. 03
1999. 01
1998. 06
1999. 01
1998. 06
1996. 07
1998. 06
1996. 07
1995. 05
1996. 07
1995. 05
1993
1993. 09
09
1995. 05
1993 091993. 09
1993. 09
1993. 091991. 11
1991. 11
1991. 111990. 12
1990. 12
1990. 121988 1988 ‐
1988 ‐ 1987. 07
1987. 07
1987. 07
Full line‐up in energy star Level IV,V and EISA V products
LED lighting division launched
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
Awarded excellent corporate prize from city government.
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
expanded production facility and building in china factory.
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
200W/250W/350W External type design launched.
WTDP registered by UL
Move to new factory,Suwon IT Complex and change company name(brand)
TCP Lap established
in china
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Gosaek
dong factory
Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
Awarded a export excellent enterprise prize from city government.
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
launched LED light driver. Contracted with LED specialized “K” Company.
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
China factory expansion (Facilitiy & Equipment)
Updated ISO9001 & ISO14001 with BP Korea and BP China factory.
China factory expansion (Facilitiy & Equipment)
WTDP registered (UL)
Move to new factory in Suwon IT complex.
WTDP registered (UL)
ISO14001 registered. merged JEC Korea and launched with new company name of Bridgepower Corp
ISO14001 registered. Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Awarded a superior technology Innovation prize from city government.
Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Registered as major supplier (power supply) to Samsung. EMI test lab established.
Registered as major supplier (power supply) to Samsung. Satisfied with ECO design partnership. President inaugurated (Mr. Heekwon Eun), Registered as S-partner (of Samsung Techwin)
Satisfied with ECO design partnership. PL Insurance insured (USD500,000) Awarded as best supplier (power supply) to LG. Satisfied with ECO design partnership. PL Insurance insured (USD500,000) Factory Move to new building Awarded as best supplier (power supply) from Samsung. Satisfied with ECO design partnership. Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) PL Insurance insured (USD500,000) (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) Factory approved by china CCC Factory Move to new building Factory approved by china CCC Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
(26-6 Wauri Bong-Dam Eup, HwaSung-Si, Gyeonggi-do, Korea) Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
Business Field Expansion (Total Power Solution) Factory approved by china CCC Business Field Expansion (Total Power Solution) Nominated as superior exporting company (City government) Established china factory (Wendeng Jeil elec Co.,Ltd. In Shandong,China)
Nominated as superior exporting company (City government) ISO9001 registered by UL (Jan. ’99) Nominated as superior exporting company (Korea government) ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Export record (over USD10M) ISO9002 registered by UL and BSI co-registered firm Export record (over USD10M) Factory
Factory approval and listed products by MITI(Japan) approval and listed products by MITI(Japan)
Awarded as superior export company from city government.
Factory
Factory approval and listed products by MITI(Japan) approval
and listed
products
by MITI(Japan)
Factory approval and listed products by Korean safety Factory
approval(EK)
: Korean
Safety
agency Factory approval and listed products by Korean safety Awarded prize (Korea president) as prominent export company. Awarded prize (Korea president) as prominent export company. Awarded prize (Korea president) as prominent export company. Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Transformer and Linear Power Supply manufacturing Transformer and Linear Power Supply manufacturing Transformer and Linear Power Supply manufacturing Established AULT KOREA CORPORATION. Established AULT KOREA CORPORATION. Capital (USD3.2million)
Established AULT KOREA CORPORATION. BridgePower Corporation
BridgePower Corporation
BridgePower Corporation
Korea Factory
Head
Office in Korea
Korea Factory
BridgePower Corporation BridgePower Corporation Wendeng Jeil Electronics
Wendeng Jeil Electronics
Wendeng Jeil Electronics
BridgePower China Factory
BridgePower Factory in China
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
History
History
Global Distribution Network
History
Company History
Global Distribution Network
2010. 03
2009. 12
2009. 01
2008. 11
2007. 04
2006. 02
2005. 11
2005. 05
2004. 01
2003. 01
2002. 11
2001. 05
2000. 08
2000. 02
1999. 01
1999. 03
1999. 01
1998. 06
1996. 07
1995. 05
1993 09
1993. 09
1993. 09
1991. 11
1990. 12
1988 ‐
1987. 07
Korea
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
USA (SL power)
Europe (SL power)
China factory expansion (Facilitiy & Equipment)
China
WTDP registered (UL)
Korea
ISO14001 registered. Japan
Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Taiwan
Registered as major supplier (power supply) to Samsung. Thailand
Satisfied with ECO design partnership. Malaysia
PL Insurance insured (USD500,000) Singapore
Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) Factory approved by china CCC Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
Business Field Expansion (Total Power Solution) Nominated as superior exporting company (City government) ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Export record (over USD10M) Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) Factory approval and listed products by Korean safety Awarded prize (Korea president) as prominent export company. Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Transformer and Linear Power Supply manufacturing Established AULT KOREA CORPORATION. China
Head Office
Manufacturing
BridgePower Corporation
964, Gosaek-dong, Gwonsun-gu, Suwon-si, Gyeonggi-do, 441-813, Korea
Tel : 82-31-299-1234
Fax : 82-31-224-0566
Email : inquiry@bridgepower.co.kr
www.bridgepower.co.kr
Wendeng Jeil Electronics ( BridgePower China Factory )
Dong Shou GuangZhou Lu KaiFa-Qu Wendeng-Shi, Shandong Province, China
Tel : 86-631-835-0010
Fax : 86-631-835-0020
Email : sybaek@bridgepower.co.kr
www.bridgepower.co.kr
Korea
BridgePower Corporation
964, Gosaek-dong, Gwonsun-gu, Suwon-si, Gyeonggi-do, 441-813, Korea
Tel : 82-31-299-1234
Fax : 82-31-224-0566
Email : inquiry@bridgepower.co.kr
www.bridgepower.co.kr
BridgePower Corporation
Korea Factory
BridgePower Corporation Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
Global
Distribution
History
Network
Index
ITE & PoE Power Supply
ITE / Switching Mode Power Supply
Output
Model
Watts
3.0V
3.3V
5.0V
6.0V
2.0A
BPI010S
12W
2.0A
BPI011S
12W
2.0A
BPI012S
12W
BPI020S
20W
BPI030S
30W
4.0A
BPI040S
40W
5.0A
BPI050S
50W
6.0A
5.0A
BPI060S
60W
7.0A
6.0A
JPW180KA
JPW190KB
7.0V
7.5V
9V
12V
1.6A
1.1A
1.1A
14V
15V
16V
18V
24V
48V
Page
1.0A
0.8A
0.75A
0.67A
0.5A
0.25A
A1
1.0A
0.8A
1.0A
3.0A
3.0A
2.5A
A2
0.8A
A3
2.0A
2.0A
1.5A
1.2A
1.2A
1.0A
0.75A
0.4A
A4
3.0A
3.0A
2.5A
2.1A
2.0A
1.67A
1.33A
0.67A
A5
4.0A
3.4A
2.7A
2.2A
1.7A
0.83A
A6
5.0A
4.2A
3.36A
3.15A
2.8A
2.1A
1.1A
A7
6.0A
5.0A
4.0A
3.75A
3.4A
2.7A
1.3A
A8
80W
6.5A
5.2A
4.33A
3.25A
90W
7.0A
6.0A
5.0A
3.75A
1.87A
A10
JPW1100KB 100W
7.5A
6.4A
5.56A
4.17A
2.1A
A11
5.0A
2.5A
A12
A9
BPI121S
120W
10A
8.0A
6.67A
BPI131S
130W
10.8A
8.67A
7.2A
5.4A
A13
BPI150S
150W
12.5A
10.0A
8.3A
6.25A
A14
BPI200S
200W
16.7A
13.35A
11.15A 8.35A
A15
BPI350S
350W
25A
20A
19.4A 14.58A
A16
PoE / Switching Mode Power Supply
Output
Model
BPE020A/
PENB1020A
Watts
3.0V
3.3V
5.0V
6.0V
7.0V
7.5V
9V
12V
13.5V
15V
16V
20W
BPE020B/
15.4W
PENB1020B
BPE035B/
PENB1035B
35W
BridgePower Corporation
48V
56
0.4A
E1
0.32A
E2
0.62A
Tel : +82-31-299-1234
Page
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
E3
Index
Index
Medical Power Supply
Medical / Switching Mode Power Supply
Output
Model
Watts
3.0V
3.3V
5.0V
6.0V
2.0A
7.0V
7.5V
9V
12V
1.6A
1.1A
14V
15V
16V
18V
24V
48V
Page
1.0A
0.8A
0.75A
0.67A
0.5A
0.25A
M1
1.1A
1.0A
0.8A
2.0A
2.0A
1.5A
1.2A
1.2A
1.0A
0.75A
0.4A
M3
3.0A
3.0A
2.5A
2.1A
2.0A
1.67A
1.33A
0.67A
M4
4.0A
3.4A
2.7A
2.2A
1.7A
0.83A
M5
BPM010S
12W
2.0A
BPM011S
12W
2.0A
BPM020S
20W
BPM030S
30W
4.0A
BPM040S
40W
5.0A
BPM050S
50W
6.0A
5.0A
5.0A
4.2A
3.36A
3.15A
2.8A
2.1A
1.1A
M6
BPM060S
60W
7.0A
6.0A
6.0A
5.0A
4.0A
3.75A
3.4A
2.7A
1.3A
M7
JMW180KA
80W
6.5A
5.2A
4.33A
3.25A
JMW190KB
90W
7.0A
6.0A
5.0A
3.75A
1.87A
M9
JMW1100KB 100W
7.5A
6.4A
5.56A
4.17A
2.1A
M10
5.0A
M11
3.0A
3.0A
2.5A
M2
M8
BPM121S
120W
10A
8.0A
6.67A
BPM131S
130W
10.8A
8.67A
7.2A
5.4A
M12
BPM150S
150W
12.5A
10.0A
8.3A
6.25A
M13
BPM200S
200W
16.7A
13.35A
11.15A 8.35A
M14
BPM350S
350W
25A
20A
19.4A 14.58A
M15
Tel : +82-31-299-1234
Fax : +82-31-224-0566
BridgePower Corporation
http://www.bridgepower.co.kr
Index
History
Index
Company History
Battery
Charger
2010. 03
2009. 12
2009. 01
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
2008. 11
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
2007. 04
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
2006. 02
China factory expansion (Facilitiy & Equipment)
2005. 11
WTDP registered (UL)
2005. 05
ISO14001 registered. 2004. 01
Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Li-ion/Li-polymer
Battery
Chargers
2003. 01
Registered as major supplier (power supply) to Samsung. Output
4.2V
8.4V
12.6V
16.8V
21.0V
25.2V
29.4V
Satisfied with ECO design partnership. Watts
Model
(1 cell)
(2 cell)
(3 cell)
(4 cell)
(5 cell)
(6 cell)
(7 cell)
2002. 11
PL Insurance insured (USD500,000) BL607
Series
7W
1.0A
0.8A
2001. 05
Factory Move to new building BL600 Series
18W
1.7A
1.4A
1.0A
(26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) JBL702A
Series
20W
2.0A
2.0A
1.5A
1.2A
1.0A
2000. 08
Factory approved by china CCC JBL745-1
Series
45W
5.0A
3.33A
2.5A
2.0A
1.7A
1.5A
2000. 02
Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
BPL910S
Series
17W
1.0A-1.5A 0.8A-1.5A
1.2A
1.0A
1999. 01
Business Field Expansion (Total Power Solution) BPL775S
Series
75W
6A
5A
4.5A
3.5A
3.0A
2.5A
1999. 03
Nominated as superior exporting company (City government) BPL150S
Series
150W
12A
10A
8A
7A
6A
5A
1999. 01
ISO9001 registered by UL (Jan. ’99) 1998. 06
Established R&D LAB & TCP Lab., Ni_MH/Ni_Cd
Battery
Chargers
1996. 07
ISO9002 registered by UL and BSI co‐registered firm Output
3.0V
4.5V
6.0V
7.5V
9.0V 10.5V 12.0V 13.5V 15.0V 16.5V 18.0V 19.5V 21.0V
1995. 05
Export record (over USD10M) Watts
Model09
(2
c)
(3
c)
(4 and
c) listed
(5 c) products
(6 c) by(7MITI(Japan)
c)
(8 c)
(9 c)
(10 c) (11 c) (12 c) (13 c) (14 c)
1993
1993. 09
Factory
Factory approval and listed products by MITI(Japan) approval
BCM
Series 18W
1.5A
1.5A
1.5A
1.5A
1.2A
1.2A
1.2A
1.2A
1.0A
1.0A
1993. 09
Factory approval and listed products by Korean safety BCW
Series
25W
1.5A
1.5A
1.5A
1.5A
1.5A
1.5A
1.5A
1991. 11
Awarded prize (Korea president) as prominent export company. JBN730-A5
2.2A
2.2A
2.2A
2.2A
2.0A
1.8A
1.5A
1.5A
1.2A
1.0A
1990. 12 22W
Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing 1988 ‐
Transformer and Linear Power Supply manufacturing 1987. 07
Established AULT KOREA CORPORATION. Sealed
Lead Acid Battery
Chargers
Output
Model
Watts
7.35V
14.7V
22.0V
29.4V
36.7V
44.0V
51.5V
(6V)
(12V)
(18V)
(24V)
(36V)
(48V)
(60V)
Page
B1
B2
B3
B4
B5
B6
B7
Page
B9
B10
B11
Page
BA500 Series
7W
1.0A
0.5A
0.3A
B12
BVL Series
17W
2.0A
1.2A
0.6A
B13
BVW series
36W
3.8A
2.25A
1.25A
B14
BHW Series
32W
3.55A
2.0A
1.1A
B15
JBL745-2 Series
45W
5.0A
2.5A
1.5A
B16
BridgePower Corporation
Korea Factory
BridgePower Corporation
BridgePower Corporation Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82-31-299-1234
Fax : +82-31-224-0566
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
Index
History
History
Index
Company History
LED DRIVER
2010. 03
2009. 12
2009. 01
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
2008. 11
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
2007. 04
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
2006. 02
China factory expansion (Facilitiy & Equipment)
2005. 11
WTDP registered (UL)
2005. 05
ISO14001 registered. 2004. 01
Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. LED
/
Switching
Mode Power Supply
2003. 01
Registered as major supplier (power supply) to Samsung. Output
16 30 34 45 62 Satisfied with ECO design partnership. Watts
32V
44V
42V
66V
88V
Model
2002. 11
PL Insurance insured (USD500,000) BPR010S40
10W
0.25A
2001. 05
Factory Move to new building BPR018S40 18W (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) 0.4A
BPR020S40
20W
0.5A
2000. 08
Factory approved by china CCC BPR025S40 23WEstablished china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
0.57
2000. 02
BPR025S88 25WBusiness Field Expansion (Total Power Solution) 0.35A
1999. 01
BPR028S44 23WNominated as superior exporting company (City government) 0.7A
1999. 03
BPR050S88
50W
0.78A
1999. 01
ISO9001 registered by UL (Jan. ’99) BPR063S88 63WEstablished R&D LAB & TCP Lab., 0.78A
1998. 06
BPR062S44 62WISO9002 registered by UL and BSI co‐registered firm 1.4A
0.7A
1996. 07
BPR092S88 92WExport record (over USD10M) 1.05A
1995. 05
BPR123S88
123W
1.4A
1993 09
1993. 09
Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) 1993. 09
Factory approval and listed products by Korean safety 1991. 11
Awarded prize (Korea president) as prominent export company. 1990. 12
Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing 1988 ‐
Transformer and Linear Power Supply manufacturing 1987. 07
Established AULT KOREA CORPORATION. BridgePower Corporation
Korea Factory
BridgePower Corporation
BridgePower Corporation Page
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
Index
History
Index
Index
Internal Power Supplies
Internal Power Supplies
AE Series
AEOutput
Series
Output
Model
Watts
3.0V
3.3V
3.0V
5.0V
6.0V
7.0V
7.5V
9V
12V
13.5V
15V
16V
18V
24V
48V
Page
5.0V
3.0A
6.0V
7.0V
7.5V
9V
1.7A
12V
1.3A
13.5V
15V
1.0A
16V
18V
24V
0.6A
48V
Page
N1
Model
AE15S
Watts
15W
AE15S
AE30S
15W
30W
3.0A
6.0A
1.7A
3.3A
1.3A
2.5A
1.0A
2.0A
0.6A
1.3A
N1
N2
AE30S
AE50S
30W
50W
6.0A
10.0A
3.3A
5.5A
2.5A
4.2A
2.0A
3.3A
1.3A
2.1A
N2
N3
AE50S
AE60S
50W
60W
10.0A
12.0A
5.5A
6.7A
4.2A
5.0A
3.3A
4.0A
2.1A
2.5A
N3
N4
AE60S
60W
12.0A
6.7A
5.0A
4.0A
2.5A
N4
3.3V
Input Configuration
Input Configuration
Output
Configuration (Output Connectors)
P1
P2-P9
Output Configuration (Output Connectors)
P2-P9
Customaized Products
Network
Customaized Products
Network
P1
Set-Top Box
Set-Top Box
Information
Information
Industrial
Industrial
BridgePower Corporation
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
Index
Index
ITE Power
EXTERNAL Power Supplies
I.T.E / Switching Mode Power Supply
BridgePower Corporation Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
A
ITE / Switching Mode Power Supply
BPI010S Universal 10-12 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 10W-12W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop and Wall Plug Style with Interchangeable Blades
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI010-S-05-X-XX
5
2.00
10.0
70
BPI010-S-06-X-XX
6
2.00
12.0
60
BPI010-S-07-X-XX
7.5
1.60
12.0
75
BPI010-S-09-X-XX
9
1.10
9.9
90
BPI010-S-12-X-XX
12
1.00
12.0
120
BPI010-S-15-X-XX
15
0.80
12.0
150
BPI010-S-16-X-XX
16
0.75
12.0
160
BPI010-S-18-X-XX
18
0.67
12.1
180
BPI010-S-24-X-XX
24
0.50
12.0
240
BPI010-S-48-X-XX
48
0.25
12.0
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.3A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max. (except 5V model)
Hold-up Time
10ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Case and Dimension
3.3(L) x 1.81(W) x 1.26(H) [in]
Relative Humidity
5% to 95% non-condensing
(LP3)
84(L) x 46(W) x 32(H) [mm]
Case Material
Black 94V0 Polycarbonate
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
83(L) x 47(W) x 37(H) [mm] (Changeable)
Cord and Connectors
20 AWG 1,500mm 2 Conductor.
Input Configuration
Other cable and connectors are available.
IEC320
IEC320
IEC320
N.A/Japan
Europe
C14 (F)
C8 (N)
C18 (Q)
/China (B)
/Korea (M) Kingdom (G)
United
Australia
(H)
Specify the input configuration Code in your Order.
Part Number Key
BPI010
Product Family Name
S
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A1
ITE / Switching Mode Power Supply
BPI011S Universal 10-12 Watt Series
I.T.E
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 10W-12W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Wall Plug Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI011-S-05-X-XX
5
2.00
10.0
70
BPI011-S-09-X-XX
9
1.10
9.9
90
BPI011-S-12-X-XX
12
1.00
12.0
120
BPI011-S-15-X-XX
15
0.80
12.0
150
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.3A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max. (except 5V model)
Hold-up Time
10ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Case and Dimension
3.09(L) x 3.38(W) x 1.18(H) [in]
Relative Humidity
5% to 95% non-condensing
(JEC#14)
78.5(L) x 86(W) x 30(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
20 AWG 1,500mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
N.A/Japan
Europe
/China (B)
/Korea (M)
Specify the input configuration Code in your Order.
Part Number Key
BPI011
Product Family Name
S
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A2
ITE / Switching Mode Power Supply
BPI012S Universal 12 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 10W-12W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Wall Plug Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
12
1.00
12.0
120
BPI012-S-12-X-XX
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.3A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max. (except 5V model)
Hold-up Time
10ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
2.75(L) x 1.92(W) x 2.86(H) [in]
70.0(L) x 48.9(W) x 72.7(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
20 AWG 1,500mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
N.A/Japan
Europe
/China (B)
/Korea (M)
Specify the input configuration Code in your Order.
Part Number Key
BPI011
Product Family Name
S
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A3
ITE / Switching Mode Power Supply
BPI020S Universal 10-20 Watt Series
I.T.E
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 10W-20W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop and Wall Plug Style with Interchangeable Blades
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI020-S-03-X-XX
3.3
3.00
9.9
33
BPI020-S-05-X-XX
5
3.00
15.0
50
BPI020-S-06-X-XX
6
2.50
15.0
60
BPI020-S-07-X-XX
7.5
2.00
15.0
75
BPI020-S-09-X-XX
9
2.00
18.0
90
BPI020-S-12-X-XX
12
1.50
18.0
120
BPI020-S-14-X-XX
14
1.20
16.8
140
BPI020-S-15-X-XX
15
1.20
18.0
150
BPI020-S-18-X-XX
18
1.00
18.0
180
BPI020-S-24-X-XX
24
0.75
18.0
240
BPI020-S-48-X-XX
48
0.40
19.2
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.5A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
61,320 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Case and Dimension
3.3(L) x 1.81(W) x 1.26(H) [in]
84(L) x 46(W) x 32(H) [mm]
83(L) x 47(W) x 37(H) [mm] (Changeable)
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
18 AWG 1,500mm 2 Conductor.
Input Configuration
Other cable and connectors are available.
IEC320
IEC320
IEC320
N.A/Japan Europe
United
Australia
C14 (F)
C8 (N)
C18 (Q)
/China (B) /Korea (M)
Kingdom (G)
(H)
Specify the input configuration Code in your Order.
Part Number Key
BPI020
Product Family Name
S
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A4
ITE / Switching Mode Power Supply
BPI030S Universal 20-30 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 20W-30W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop and Wall Plug Style with Interchangeable Blades
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI030-S-05-X-XX
5
4.00
20.0
50
BPI030-S-07-X-XX
7.5
3.00
22.5
75
BPI030-S-09-X-XX
9
3.00
27.0
90
BPI030-S-12-X-XX
12
2.50
30.0
120
BPI030-S-14-X-XX
14
2.10
29.4
150
BPI030-S-15-X-XX
15
2.00
30.0
160
BPI030-S-18-X-XX
18
1.67
30.1
180
BPI030-S-24-X-XX
24
1.33
31.9
240
BPI030-S-48-X-XX
48
0.67
32.2
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
1.0A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
61,320 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
3.74(L) x 2.13(W) x 1.26(H) [in]
95.0(L) x 54.0(W) x 32.0(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
18 AWG 1,500mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
N.A/Japan Europe
United
Australia
C14 (F)
C8 (N)
C18 (Q)
/China (B) /Korea (M)
Kingdom (G)
(H)
Specify the input configuration Code in your Order.
Part Number Key
BPI030
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A5
ITE / Switching Mode Power Supply
BPI040S Universal 25-40 Watt Series
I.T.E
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 25W-40W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI040-S-05-X-XX
5
5.00
25.0
50
BPI040-S-09-X-XX
9
4.00
36.0
90
BPI040-S-12-X-XX
12
3.40
40.8
120
BPI040-S-15-X-XX
15
2.70
40.5
150
BPI040-S-18-X-XX
18
2.20
39.6
180
BPI040-S-24-X-XX
24
1.70
40.8
240
BPI040-S-48-X-XX
48
0.83
39.8
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
1.2A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
61,320 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
4.01(L) x 2.36(W) x 1.26(H) [in]
102(L) x 60(W) x 32(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG 1,200mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C8 (N)
C18 (Q)
Specify the input configuration Code in your Order.
Part Number Key
BPI040
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A6
ITE / Switching Mode Power Supply
BPI050S Universal 30-50 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 30W-50W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI050-S-05-X-XX
5
6.00
30.0
50
BPI050-S-06-X-XX
6
5.00
30.0
60
BPI050-S-09-X-XX
9
5.00
45.0
90
BPI050-S-12-X-XX
12
4.20
50.4
120
BPI050-S-15-X-XX
15
3.36
50.4
150
BPI050-S-16-X-XX
16
3.15
50.4
160
BPI050-S-18-X-XX
18
2.80
50.4
180
BPI050-S-24-X-XX
24
2.10
50.4
240
BPI050-S-48-X-XX
48
1.10
52.8
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
1.5A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622 or ≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
4.20(L) x 2.60(W) x 1.46(H) [in]
107(L) x 66(W) x 37(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
18 AWG 1,500mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C8 (N)
C18 (Q)
Specify the input configuration Code in your Order.
Part Number Key
BPI050
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A7
ITE / Switching Mode Power Supply
BPI060S Universal 40-60 Watt Series
I.T.E
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 40W-60W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI060-S-05-X-XX
5
7.00
35.0
50
BPI060-S-06-X-XX
6
6.00
36.0
60
BPI060-S-09-X-XX
9
6.00
54.0
90
BPI060-S-12-X-XX
12
5.00
60.0
120
BPI060-S-15-X-XX
15
4.00
60.0
150
BPI060-SA-16-X-XX
3.75
60.0
160
BPI060-S-18-X-XX
16
18
3.40
61.2
180
BPI060-S-24-X-XX
24
2.70
64.8
240
BPI060-S-48-X-XX
48
1.30
62.4
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
1.5A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622 or ≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
4.20(L) x 2.60(W) x 1.46(H) [in]
107(L) x 66(W) x 37(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
18 AWG 1,500mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C8 (N)
C18 (Q)
Specify the input configuration Code in your Order.
Part Number Key
BPI060
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A8
ITE / Switching Mode Power Supply
JPW180KA Universal 80 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 80W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
JPW180-KA-12-XX-X-XX
12
6.50
78.0
120
JPW180-KA-15-XX-X-XX
15
5.20
78.0
150
JPW180-KA-18-XX-X-XX
18
4.33
77.9
180
JPW180-KA-24-XX-X-XX
24
3.25
78.0
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
1.5A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
61,320 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
5.12(L) x 2.82(W) x 1.71(H) [in]
130(L) x 71.5(W) x 43.5(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
20 AWG 1,200mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
JPW180
Product Family Name
KA
12
XX
X
XX
Design Revision Change
Volt (DC)
Connector Number
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A9
ITE / Switching Mode Power Supply
JPW190KB Universal 85-90 Watt Series
I.T.E
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 85-90W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
JPW190-KB-12-XX-X-XX
12
7.00
84.0
120
JPW190-KB-13-XX-X-XX
13.5
6.00
81.0
135
JPW190-KB-15-XX-X-XX
15
6.00
90.0
150
JPW190-KB-18-XX-X-XX
18
5.00
90.0
180
JPW190-KB-24-XX-X-XX
24
3.75
90.0
240
JPW190-KB-48-XX-X-XX
48
1.87
89.8
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
2.0A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
5.08(L) x 3.05(W) x 1.59(H) [in]
129(L) x 77(W) x 40(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C18 (Q)
C8 (N)
Specify the input configuration Code in your Order.
Part Number Key
JPW190
Product Family Name
KB
12
XX
X
XX
Design Revision Change
Volt (DC)
Connector Number
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A10
ITE / Switching Mode Power Supply
JPW1100KB Universal 90-100 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 90-100W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
JPW1100-KB-12-XX-X-XX
12
7.50
90.0
120
JPW1100-KB-13-XX-X-XX
13
6.92
90.0
130
JPW1100-KB-15-XX-X-XX
15
6.40
96.0
150
JPW1100-KB-16-XX-X-XX
16
6.00
96.0
160
JPW1100-KB-18-XX-X-XX
18
5.60
100.8
180
JPW1100-KB-19-XX-X-XX
19
5.20
98.8
190
JPW1100-KB-24-XX-X-XX
24
4.20
100.8
240
JPW1100-KB-48-XX-X-XX
48
2.10
100.8
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
2.2A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
5.87(L) x 3.37(W) x 1.87(H) [in]
149(L) x 85.5(W) x 47.5(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C18 (Q)
C8 (N)
Specify the input configuration Code in your Order.
Part Number Key
JPW1100
Product Family Name
KB
12
XX
X
XX
Design Revision Change
Volt (DC)
Connector Number
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A11
ITE / Switching Mode Power Supply
BPI121S Universal 120 Watt Series
I.T.E
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 120W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI121-S-12-X-XX
12
10.00
120.0
120
BPI121-S-15-X-XX
15
8.00
120.0
150
BPI121-S-18-X-XX
18
6.67
120.1
180
BPI121-S-24-X-XX
24
5.00
120.0
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
3.0A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Half bridge
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
8.2(L) x 2.5(W) x1.6(H) [in]
209.4(L) x 64.4(W) x 41.5(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG or 18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPI121
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A12
ITE / Switching Mode Power Supply
BPI131S Universal 130 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 130W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI131-S-12-X-XX
12
10.80
129.6
120
BPI131-S-15-X-XX
15
8.67
130.1
150
BPI131-S-18-X-XX
18
7.20
129.6
180
BPI131-S-24-X-XX
24
5.40
129.6
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
3.0A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Half bridge
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
8.2(L) x 2.5(W) x1.6(H) [in]
209.4(L) x 64.4(W) x 41.5(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG or 18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPI131
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A13
ITE / Switching Mode Power Supply
BPI150S Universal 150 Watt Series
I.T.E
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 150W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI150-S-12-X-XX
12
12.50
150.0
120
BPI150-S-15-X-XX
15
10.00
150.0
150
BPI150-S-18-X-XX
18
8.30
149.4
180
BPI150-S-24-X-XX
24
6.25
150.0
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
3.0A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Half bridge
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
8.2(L) x 2.5(W) x1.6(H) [in]
209.4(L) x 64.4(W) x 41.5(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG or 18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPI150
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A14
ITE / Switching Mode Power Supply
BPI200S Universal 200 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 200W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI200-S-12-X-XX
12
16.70
200.4
120
BPI200-S-15-X-XX
15
13.35
200.3
150
BPI200-S-18-X-XX
18
11.15
200.7
180
BPI200-S-24-X-XX
24
8.35
200.4
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
3.5A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Half bridge
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
8.27(L) x 3.19(W) x 1.83(H) [in]
210(L) x 81(W) x 46.4(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG or 18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPI200
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A15
ITE / Switching Mode Power Supply
BPI350S Universal 350 Watt Series
BPI350S Universal 350 Watt Series
Universal
350 Watt Series
•BPI350S
100-240 Vac Universal
Input
ITE / Switching Mode Power Supply
ITE / Switching Mode Power Supply
I.T.E
• Single Output to 350W
100-240 Vac
Universal
Input
• Regulated
Output
with Low
Ripple
Single
Output
to
350W
100-240
VacAgency
Universal
Input
• Meets
Safety
Requirements
Regulated
Output
with Low Ripple
Single
Output
to 350W
• Impact
Resistant
Polycarbonate
Enclosure
Meets Safety
Agency
Requirements
Regulated
Output
with
Low Ripple
• Modified
and
Custom
Designs
Also Available
Impact
Resistant
Polycarbonate
Enclosure
Meets Safety
Requirements
• Desktop
StyleAgency
Modified
and Custom
Designs Also
Available
• Impact
Resistant
Polycarbonate
Enclosure
Desktop Style
• Modified
and Custom Designs Also Available
• Desktop Style
Model
Output Voltage
Maximum
Maximum
Ripple
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPI350-S-12-X-XX
Output12
Voltage
Maximum
25.00
Maximum
300.0
Ripple
120
BPI350-S-15-X-XX
DC15
(V)
Output
Voltage
Current
Maximum
20.00(A)
Watts
Maximum
300.0(W)
Vp-pRipple
max.
150 (mV)
BPI350-S-12-X-XX
BPI350-S-18-X-XX
DC18
12(V)
Current
25.00(A)
19.40
Watts
300.0(W)
349.2
Vp-p max.
120 (mV)
180
BPI350-S-15-X-XX
BPI350-S-12-X-XX
BPI350-S-24-X-XX
15
12
24
20.00
25.00
14.58
300.0
349.9
150
120
240
BPI350-S-18-X-XX
BPI350-S-15-X-XX
18
15
19.40
20.00
349.2
300.0
180
150
BPI350-S-24-X-XX
BPI350-S-18-X-XX
24
18
14.58
19.40
349.9
349.2
240
180
BPI350-S-24-X-XX
24
14.58
349.9
240
Model
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line
Frequency
Input
Specification
47 to 63 Hz
Leakage
GeneralCurrent
Specification
Less than 250uA
Voltage
Range
Input
InputCurrent
Specification
100 to
240VAC
-10%,Input
+10%
5.0A
max.
at 90VAC
Topology
Dielectric
Withstand
General Specification
Switching -Primary
Half bridge
4,242VDC
- Secondary
InputFrequency
Voltage Range
Line
Protection
47
Hz
100toto63
240VAC
-10%,
+10%
Internal
Primary
Current
Fuse, Inrush Limiting
Leakage Current
Topology
Less than 250uA
Switching
-Primary
Half bridge
2,150VDC
- F.G
InputFrequency
Current
Line
5.0A
47
tomax.
63 Hzat 90VAC Input
Dielectric
Withstand
Leakage Current
4,242VDC
Primary --Secondary
Less thanSecondary
250uA
500VDC
F.G
Protection
Input
Current
Output
Specification
Internal
Primary
Current
5.0A max.
at 90VAC
InputFuse, Inrush Limiting
DielectricTemperature
Withstand
Storage
2,150VDC
- F.G
4,242VDC
Secondary
-30
˚C to 85Primary
˚C
Protection
Line
& Load Regulation
Internal
Primary Current
Line
Voltage
+/-Fuse,
1% Inrush Limiting
Efficiency
500VDC
F.G
2,150VDC
Primary --F.G
≥
85% Secondary
(at End ofSpecification
Cable)
Output
Load Voltage
+/- 5%
Storage Temperature
500VDC
- F.G
-30 ˚C toSecondary
85 ˚C
Line
& Load
Regulation
Ripple
Output
Specification
LineVp-p
Voltage
1%
max.
+/- 1%
Efficiency
Storage
Temperature
Hold-up
Time
≥ 85%
18ms
-30
˚C min.
to 85@115VAC
˚C
Complies
≥ 85% with EMC Directives
Switching - Half bridge
(at End
ofResponse
Cable)
Line
& Load
Regulation
Transient
Load Voltage
Voltage
5%Typ.
Line
+/- 1%
0.5ms
for 50% Load change
Efficiency
EMI
Ripple
(at End of Cable)
Protection
1% Vp-p
max.Protection
Load
Voltage
+/-(Hiccup)
5%
Over-current
Hold-up Time
18ms min. @115VAC
Transient
Ripple Response
0.5ms
formax.
50%
Load change Typ.
1% Vp-p
Short
Circuit
Protection
EMI
Hold-up Time
MTBF
Complies
with
EMC Hours
Directives
18ms min.
@115VAC
100,000
Calculated
Minimum.
ProtectionResponse
Transient
Over-current
(Hiccup)
0.5ms for 50%Protection
Load change
Typ.
EMI
Approvals
and
Complies with
EMC Directives
UL60950-1,
IEC/EN60950-1,
K60950-1
Protection
Environmental Specification
Short Circuit Protection
Over-current
Protection (Hiccup)
MTBF Standards
Safety
100,000
Calculated
Hours
Minimum.
EMC
: EN55022
/ 55024
/ 61000
Operating Temperature
Short
Protection
0˚C
toCircuit
40˚C with
no derating
Approvals
and
MTBFand Dimension
Case
UL60950-1,
IEC/EN60950-1,
K60950-1
100,000
Hours Minimum.
12.06(L)
xCalculated
5.23(W)
x2.47(H)
[in]
Relative
Humidity Specification
Environmental
5% to 95% non-condensing
Safety Standards
Approvals
and
EMC : EN55022
/ 55024
/ 61000
UL60950-1,
IEC/EN60950-1,
K60950-1
306.5(L)
x 133(W)
x 62.8(H)
[mm]
Operating
Temperature
Altitude
Environmental
Specification
00˚C
- 10,000
to 40˚Cfeet
with no derating
and
Dimension
SafetyMaterial
Standards
Case
12.06(L)
x 5.23(W)
x2.47(H)
[in]
EMC
:94V0
EN55022
/ 55024
/ 61000
Black
Polycarbonate
Relative Humidity
Operating
Temperature
Cooling
5% to 95%
Convectional
- Non
0˚C
40˚C non-condensing
with
no vented
deratingcase
Case and Dimension
Cord
Connectors
306.5(L)
133(W)
62.8(H)
[mm]
12.06(L)
5.23(W)xx2.47(H)
[in]
16
AWG x 1,500mm
6 Conductor.
Altitude
Relative Humidity
0
5%- 10,000
to 95%feet
non-condensing
Case Material
Black
94V0
Polycarbonate
306.5(L)
x 133(W)
x 62.8(H) [mm]
Other
cable
and connectors
are available.
Cooling
Altitude
Input Configuration
Convectional
0 - 10,000 feet- Non vented case
Cord
and Connectors
Case Material
16
AWG
6 Conductor.
Black
94V01,500mm
Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
Other
cable
and connectors
are available.
16
AWG
1,500mm
6 Conductor.
Input Configuration
Other cable and connectors are available.
IEC320
Input Configuration
C14 (F)
IEC320 the input configuration Code in your Order.
Specify
C14
IEC320
Part(F)
Number Key
Specify
configuration Code in your Order.
C14
(F) the input
BPI350
S
12
X
XX
Product Family Name
Part Number BPI350
Key
BPI350
Product Family Name
Single Output
S
Volt (DC)
12
Input Configuration
X
Customer Number
XX
S
Single Output
12
Volt (DC)
Product
Family Name
BridgePower
CorporationSingle Output
Volt (DC)
X
XX
Input Configuration
Customer Number
Tel : +82-31-299-1234 Fax : +82-31-224-0566
Input Configuration
Customer Number
http://www.bridgepower.co.kr
Specify
the inputKey
configuration Code in your Order.
Part Number
BridgePower Corporation
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
A16
A16
A16
PoE
EXTERNAL Power Supplies
PoE / Switching Mode Power Supply
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
E
PoE / Switching Mode Power Supply
BPE020A /CENB1020A Universal 20 Watt
• 100-240 Vac Universal Input
• Single Output to 20W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
PoE
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
48
0.40
19.2
480
BPE020-A-48-X-XX
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.4A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
Storage Temperature
-30 ˚C to 85 ˚C
Data Rate
10/100/1000 BASE operation
Ripple & Noise
1% Vp-p max.
Hold-up Time
10ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Short Circuit Protection
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Case and Dimension
4.43(L) x 1.88(W) x 1.33(H) [in]
112.5(L) x 47.8(W) x 33.7(H) [mm]
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
RJ45 Cable.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C8 (N)
C18 (Q)
Other cable and connectors are available.
Specify the input configuration Code in your Order.
Part Number Key
BPE020
Product Family Name
A
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
E1
PoE / Switching Mode Power Supply
BPE020B /CENB1020B Universal 20 Watt
• 100-240 Vac Universal Input
• satisfies the requirements of the IEEE802.3AF
• Single Output to 15W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
48
0.32
15.4
480
BPE020-B-48-X-XX
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.4A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
Storage Temperature
-30 ˚C to 85 ˚C
Data Rate
10/100/1000 BASE operation
Ripple & Noise
1% Vp-p max.
Hold-up Time
10ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Short Circuit Protection
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Case and Dimension
4.43(L) x 1.88(W) x 1.33(H) [in]
112.5(L) x 47.8(W) x 33.7(H) [mm]
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
RJ45 Cable.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C8 (N)
C18 (Q)
Other cable and connectors are available.
Specify the input configuration Code in your Order.
Part Number Key
BPE020
Product Family Name
B
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
E2
PoE / Switching Mode Power Supply
BPE035 Universal 35 Watt
• 100-240 Vac Universal Input
• satisfies the requirements of the IEEE802.3AF & IEEE802.3AT
• Single Output to 35W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
PoE
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
56
0.62
34.7
560
BPE035-S-56-X-XX
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
1.5A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
Storage Temperature
-30 ˚C to 85 ˚C
Data Rate
10/100/1000 BASE operation
Ripple & Noise
1% Vp-p max.
Hold-up Time
10ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Short Circuit Protection
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Case and Dimension
5.23(L) x 2.12(W) x 1.38(H) [in]
133(L) x 54(W) x 35.1(H) [mm]
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
RJ45 Cable.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C8 (N)
C18 (Q)
Other cable and connectors are available.
Specify the input configuration Code in your Order.
Part Number Key
BPE035
Product Family Name
S
56
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
E3
Medical Power
EXTERNAL Power Supplies
Medical / Switching Mode Power Supply
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M
Medical / Switching Mode Power Supply
BPM010S Universal 10-12 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 10W-12W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop and Wall Plug Style with Interchangeable Blades
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM010-S-05-X-XX
5
2.00
10.0
70
BPM010-S-06-X-XX
6
2.00
12.0
60
BPM010-S-07-X-XX
7.5
1.60
12.0
75
BPM010-S-09-X-XX
9
1.10
9.9
90
BPM010-S-12-X-XX
12
1.00
12.0
120
BPM010-S-15-X-XX
15
0.80
12.0
150
BPM010-S-16-X-XX
16
0.75
12.0
160
BPM010-S-18-X-XX
18
0.67
12.1
180
BPM010-S-24-X-XX
24
0.50
12.0
240
BPM010-S-48-X-XX
48
0.25
12.0
480
Input Specification
Medical
Output Voltage
Model
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
0.3A max. at 90VAC Input
Dielectric Withstand
5,656VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise & Noise
1% Vp-p max.
Hold-up Time
10ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Case and Dimension
3.3(L) x 1.81(W) x 1.26(H) [in]
84(L) x 46(W) x 32(H) [mm]
83(L) x 47(W) x 37(H) [mm] (Changeable)
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
20 AWG 1,500mm 2 Conductor.
Input Configuration
Other cable and connectors are available.
IEC320
IEC320
IEC320
N.A/Japan
Europe
C14 (F)
C8 (N)
C18 (Q)
/China (B)
/Korea (M) Kingdom (G)
United
Australia
(H)
Specify the input configuration Code in your Order.
Part Number Key
BPM010
Product Family Name
S
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M1
ITE / Switching Mode Power Supply
BPM011S Universal 10-12 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 10W-12W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Wall Plug Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM011-S-05-X-XX
5
2.00
10.0
70
BPM011-S-09-X-XX
9
1.10
9.9
90
BPM011-S-12-X-XX
12
1.00
12.0
120
BPM011-S-15-X-XX
15
0.80
12.0
150
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.3A max. at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max. (except 5V model)
Hold-up Time
10ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
3.09(L) x 3.38(W) x 1.18(H) [in]
78.5(L) x 86(W) x 30(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
18 AWG 1,500mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
N.A/Japan
Europe
/China (B)
/Korea (M)
Specify the input configuration Code in your Order.
Part Number Key
BPM011
Product Family Name
S
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M2
Medical / Switching Mode Power Supply
BPM020S Universal 10-20 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 10W-20W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop and Wall Plug Style with Interchangeable Blades
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM020-S-03-X-XX
3.3
3.00
9.9
33
BPM020-S-05-X-XX
5
3.00
15.0
50
BPM020-S-06-X-XX
6
2.50
15.0
60
BPM020-S-07-X-XX
7.5
2.00
15.0
75
BPM020-S-09-X-XX
9
2.00
18.0
90
BPM020-S-12-X-XX
12
1.50
18.0
120
BPM020-S-14-X-XX
14
1.20
16.8
140
BPM020-S-15-X-XX
15
1.20
18.0
150
BPM020-S-18-X-XX
18
1.00
18.0
180
BPM020-S-24-X-XX
24
0.75
18.0
240
BPM020-S-48-X-XX
48
0.40
19.2
480
Input Specification
Medical
Output Voltage
Model
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
0.5A max. at 90VAC Input
Dielectric Withstand
5,656VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
61,320 Calculated Hours Minimum.
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Case and Dimension
3.3(L) x 1.81(W) x 1.26(H) [in]
84(L) x 46(W) x 32(H) [mm]
83(L) x 47(W) x 37(H) [mm] (Changeable)
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
18 AWG 1,500mm 2 Conductor.
Input Configuration
Other cable and connectors are available.
IEC320
IEC320
IEC320
N.A/Japan
Europe
C14 (F)
C8 (N)
C18 (Q)
/China (B)
/Korea (M) Kingdom (G)
United
Australia
(H)
Specify the input configuration Code in your Order.
Part Number Key
BPM020
Product Family Name
S
05
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M3
Medical / Switching Mode Power Supply
BPM030S Universal 20-30 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 20W-30W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop and Wall Plug Style with Interchangeable Blades
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM030-S-05-X-XX
5
4.00
20.0
50
BPM030-S-07-X-XX
7.5
3.00
22.5
75
BPM030-S-09-X-XX
9
3.00
27.0
90
BPM030-S-12-X-XX
12
2.50
30.0
120
BPM030-S-14-X-XX
14
2.10
29.4
150
BPM030-S-15-X-XX
15
2.00
30.0
160
BPM030-S-18-X-XX
18
1.67
30.1
180
BPM030-S-24-X-XX
24
1.33
31.9
240
BPM030-S-48-X-XX
48
0.67
32.2
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
1.0A max. at 90VAC Input
Dielectric Withstand
5,656VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626 * Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.3W
Short Circuit Protection
MTBF
61,320 Calculated Hours Minimum.
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
3.74(L) x 2.13(W) x 1.26(H) [in]
95.0(L) x 54.0(W) x 32.0(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
18 AWG 1,500mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
N.A/Japan
Europe
C14 (F)
C8 (N)
C18 (Q)
/China (B)
/Korea (M) Kingdom (G)
United
Australia
(H)
Specify the input configuration Code in your Order.
Part Number Key
BPM030
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M4
Medical / Switching Mode Power Supply
BPM040S Universal 25-40 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 25-40W
• Regulated Output with Low Ripple
• Meets Medical Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM-040-S-05-X-XX
5
5.00
25.0
50
BPM-040-S-09-X-XX
9
4.00
36.0
90
BPM-040-S-12-X-XX
12
3.40
40.8
120
BPM-040-S-15-X-XX
15
2.70
40.5
150
BPM-040-S-18-X-XX
18
2.20
39.6
180
BPM-040-S-24-X-XX
24
1.70
40.8
240
BPM-040-S-48-X-XX
48
0.83
40.8
480
Input Specification
Medical
Output Voltage
Model
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
1.2A max. at 90VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
5,656VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626* Ln (Pno)] + 0.622
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
Max. Power in No-Load
≤ 0.3W
Over-current Protection (Hiccup)
MTBF
61,320 Calculated Hours Minimum.
Short Circuit Protection
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Case and Dimension
4.01(L) x 2.36(W) x 1.26(H) [in]
Black 94V0 Polycarbonate
Protection
Environmental Specification
102(L) x 60(W) x 32(H) [mm]
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case Material
Altitude
0 - 10,000 feet
Cord and Connectors
Cooling
Convectional - Non vented case
16 AWG 1,200mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C18 (Q)
C8 (N)
Specify the input configuration Code in your Order.
Part Number Key
BPM040
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M5
Medical / Switching Mode Power Supply
BPM050S Universal 30-50 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 30-50W
• Regulated Output with Low Ripple
• Meets Medical Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM-050-S-05-X-XX
5
6.00
30.0
50
BPM-050-S-06-X-XX
6
5.00
30.0
60
BPM-050-S-09-X-XX
9
5.00
45.0
90
BPM-050-S-12-X-XX
12
4.20
50.4
120
BPM-050-S-15-X-XX
15
3.36
50.4
150
BPM-050-S-15-X-XX
16
3.15
50.4
160
BPM-050-S-18-X-XX
18
2.80
50.4
180
BPM-050-S-24-X-XX
24
2.10
50.4
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
1.5A max. at 90VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
5,656VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ [0.0626* Ln (Pno)] + 0.622 or ≥0.87
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
Max. Power in No-Load
≤ 0.5W
Over-current Protection (Hiccup)
MTBF
61,000Calculated Hours Minimum.
Short Circuit Protection
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Case and Dimension
4.20(L) x 2.60(W) x 1.46(H) [in]
Black 94V0 Polycarbonate
Protection
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case Material
Altitude
0 - 10,000 feet
Cord and Connectors
Cooling
Convectional - Non vented case
107(L) x 66(W) x 37(H) [mm]
18 AWG 1,500mm 2 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C18 (Q)
C8 (N)
Specify the input configuration Code in your Order.
Part Number Key
BPM050
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M6
Medical / Switching Mode Power Supply
BPM060S Universal 40-60 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 40-60W
• Regulated Output with Low Ripple
• Meets Medical Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM-060-S-05-X-XX
5
7.00
35.0
50
BPM-060-S-06-X-XX
6
6.00
36.0
60
BPM-060-S-09-X-XX
9
6.00
54.0
90
BPM-060-S-12-X-XX
12
5.00
60.0
120
BPM-060-S-15-X-XX
15
4.00
60.0
150
BPM-060-S-16-X-XX
16
3.75
60.0
160
BPM-060-S-18-X-XX
18
3.40
61.2
180
BPM-060-S-24-X-XX
24
2.70
64.8
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
1.5A max. at 90VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
5,656VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
Max. Power in No-Load
≤ 0.5W
Protection
Over-current Protection (Hiccup)
MTBF
61,000Calculated Hours Minimum.
Short Circuit Protection
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
≥ [0.0626* Ln (Pno)] + 0.622 or ≥0.87
Environmental Specification
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Case and Dimension
4.25(L) x 2.63(W) x 1.73(H) [in]
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case Material
108(L) x 67(W) x 44(H) [mm]
Black 94V0 Polycarbonate
Altitude
0 - 10,000 feet
Cord and Connectors
18 AWG 1,500mm 2 Conductor.
Cooling
Convectional - Non vented case
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C18 (Q)
C8 (N)
Specify the input configuration Code in your Order.
Part Number Key
BPM060
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M7
Medical / Switching Mode Power Supply
JMW180KA Universal 80 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 80W
• Regulated Output with Low Ripple
• Meets Medical Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
JMW180-KA-12-XX-X-XX
12
6.50
78.0
120
JMW180-KA-15-XX-X-XX
15
5.20
78.0
150
JMW180-KA-18-XX-X-XX
18
4.33
77.9
180
JMW180-KA-24-XX-X-XX
24
3.25
78.0
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
1.5A max. at 90VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
5,656VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 0.87
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
Max. Power in No-Load
≤ 0.5W
Over-current Protection (Hiccup)
MTBF
61,000Calculated Hours Minimum.
Short Circuit Protection
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Case and Dimension
5.12(L) x 2.82(W) x 1.71(H) [in]
Protection
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
(JEC#19)
130(L) x 71.5(W) x 43.5(H) [mm]
Relative Humidity
5% to 95% non-condensing
Case Material
Black 94V0 Polycarbonate
Altitude
0 - 10,000 feet
Cord and Connectors
Cooling
Convectional - Non vented case
20 AWG 1,200mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
JMW180
Product Family Name
KA
12
XX
X
XX
Design Revision Change
Volt (DC)
Connector Number
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M8
Medical / Switching Mode Power Supply
JMW190KB Universal 90 Watt Series
JMW190KB Universal
Universal 90
90 Watt
Watt Series
Series
JMW190KB
Medical / Switching Mode Power Supply
Medical / Switching Mode Power Supply
100-240 Vac Universal Input
M
ENERGY STAR P
R u
• 100-240 Vac Universal Input
S
Ou Vac
u Universal
W Input
• 100-240
• Meets "ENERGY STAR" Program Requirements
R u "ENERGY
Ou uSTAR" LProgram
R Requirements
• Meets
• Single Output to 90W
M
S
Ato 90WR u
• Single
Output
• Regulated Output with Low Ripple
I
R OutputPwith Low Ripple
E
u
• Regulated
• Meets Safety Agency Requirements
M
Cu
D
A A
• Meets
Safety Agency
Requirements
• Impact Resistant Polycarbonate Enclosure
D
S
• Impact
Resistant
Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Modified and Custom Designs Also Available
• Desktop Style
• Desktop Style
Model
JMW190-KB-12-XX-X-XX
Model
Model
Maximum
Maximum
Ripple
DC (V)
Output Voltage
Output12
Voltage
DC (V)
13.5
DC
(V)
Current (A)
Maximum
7.00
Maximum
Current (A)
6.00 (A)
Current
Watts (W)
Maximum
84.0
Maximum
Watts (W)
81.0(W)
Watts
Vp-p max. (mV)
Ripple
120
Ripple
Vp-p max. (mV)
135 (mV)
Vp-p max.
12
15
12
13.5
18
13.5
15
24
15
18
48
18
24
24
48
48
7.00
6.00
7.00
6.00
5.00
6.00
6.00
3.75
6.00
5.00
1.87
5.00
3.75
3.75
1.87
1.87
Input Specification
100 to 240VAC -10%, +10%
Input Voltage Range
Current Range
Input Voltage
Line Frequency
Protection
Line
Frequency
Input Current
Input Current
Protection
Output Specification
Protection
47 to 63 Hz
100 to 240VAC -10%, +10%
2.0Ato
max.
at 90VAC
100
240VAC
-10%,Input
+10%
47 to 63 Hz
Internal
Current Fuse, Inrush Limiting
47
to 63 Primary
Hz
2.0A max. at 90VAC Input
2.0A max. at 90VAC Input
Internal Primary Current Fuse, Inrush Limiting
Internal Primary Current Fuse, Inrush Limiting
Line & Load Regulation
Line Voltage
Line & Load Regulation
Ripple
Line
& Load Regulation
(at End of Cable)
Transient
(at End ofResponse
Cable)
Ripple
Protection
Ripple
Transient Response
Transient Response
Protection
Protection
Output Specification
(at End ofSpecification
Cable)
Output
Topology
General Specification
Leakage Current
General
Specification
Topology
Dielectric Withstand
Topology
Leakage Current
Leakage Current
Dielectric Withstand
Dielectric Withstand
Storage Temperature
+/- 1%
Environmental Specification
Load Voltage
+/- 5%
Line Voltage
+/- 1%
1% Vp-p
max.
Line
Voltage
+/- 1%
Load Voltage
+/- 5%
0.5msVoltage
for 50% Load change
Load
+/- 5%Typ.
1% Vp-p max.
Over-current
1%
Vp-p max.Protection (Hiccup)
0.5ms for 50% Load change Typ.
Short Circuit
Protection
0.5ms
for 50%
Load change Typ.
Over-current Protection (Hiccup)
Over-current Protection (Hiccup)
Short Circuit Protection
Short Circuit Protection
Operating Temperature
0˚C to 40˚C with no derating
Operating Temperature
Altitude Temperature
Operating
Relative Humidity
Cooling Humidity
Relative
Altitude
Altitude
Cooling
Input Configuration
Cooling
5% to 95% non-condensing
0˚C to 40˚C with no derating
0 - 10,000
0˚C
to 40˚Cfeet
with no derating
5% to 95% non-condensing
Convectional
- Non vented case
5%
to 95% non-condensing
0 - 10,000 feet
0 - 10,000 feet
Convectional - Non vented case
Convectional - Non vented case
Environmental Specification
Relative Humidity Specification
Environmental
Efficiency
Storage Temperature
Storage Temperature
Efficiency
Hold-up Time
Efficiency
EMI
Hold-up Time
Max. Power
Hold-up
Timein No-Load
EMI
MTBF
EMI
Max. Power in No-Load
Approvals
and
Max.
Power
in No-Load
MTBF
Safety Standards
MTBF
Approvals and
Case and Dimension
Approvals
and
Safety Standards
Safety Standards
Case and Dimension
Material
Case and
Dimension
Cord and Connectors
Case Material
Case Material
Cord and Connectors
Cord and Connectors
Input Configuration
Input Configuration
IEC320
IEC320
120
150
120
135
180
135
150
240
150
180
480
180
240
240
480
480
General Specification
Input Voltage Range
Input Specification
Line Frequency
Input
Specification
84.0
90.0
84.0
81.0
90.0
81.0
90.0
90.0
90.0
89.8
90.0
90.0
90.0
89.8
89.8
Medical
JMW190-KB-13-XX-X-XX
JMW190-KB-12-XX-X-XX
JMW190-KB-15-XX-X-XX
JMW190-KB-12-XX-X-XX
JMW190-KB-13-XX-X-XX
JMW190-KB-18-XX-X-XX
JMW190-KB-13-XX-X-XX
JMW190-KB-15-XX-X-XX
JMW190-KB-24-XX-X-XX
JMW190-KB-15-XX-X-XX
JMW190-KB-18-XX-X-XX
JMW190-KB-48-XX-X-XX
JMW190-KB-18-XX-X-XX
JMW190-KB-24-XX-X-XX
JMW190-KB-24-XX-X-XX
JMW190-KB-48-XX-X-XX
JMW190-KB-48-XX-X-XX
Output Voltage
Switching - Fixed Frequency Flyback
Less than 100uA
Switching - Fixed Frequency Flyback
5,656VDC -Primary
- Secondary
Switching
Fixed Frequency
Flyback
Less than 100uA
2,545VDC
Primary - F.G
Less
than 100uA
5,656VDC Primary - Secondary
500VDC Secondary
F.G
5,656VDC
Primary --Secondary
2,545VDC Primary - F.G
-30 ˚C to 85
˚C
2,545VDC
Primary
- F.G
500VDC Secondary - F.G
Minimum
Average Efficyency
in Active Mode
500VDC
Secondary
- F.G
-30 ˚C to 85 ˚C
≥ 87%
-30
˚C to 85 ˚C
Minimum Average Efficyency in Active Mode
18ms min.Average
@115VAC
Minimum
Efficyency in Active Mode
≥ 87%
Complies
≥
87% with EMC Directives
18ms min. @115VAC
≤ 0.5W
18ms
min. @115VAC
Complies with EMC Directives
100,000 Calculated
Minimum.
Complies
with EMC Hours
Directives
≤ 0.5W
UL60601-1,
IEC/EN60601-1, K60950-1
≤
0.5W
100,000 Calculated Hours Minimum.
EMC : EN60601-1-1-2
/ EN55011
100,000
Calculated Hours
Minimum.
UL60601-1, IEC/EN60601-1, K60950-1
5.08(L) x 3.05(W)
x 1.59(H) [in]
UL60601-1,
IEC/EN60601-1,
K60950-1
EMC : EN60601-1-1-2 / EN55011
129(L): EN60601-1-1-2
x 77(W) x 40(H)/[mm]
EMC
EN55011
5.08(L) x 3.05(W) x 1.59(H) [in]
Black 94V0
Polycarbonate
5.08(L)
x 3.05(W)
x 1.59(H) [in]
129(L) x 77(W) x 40(H) [mm]
18 AWG
1,500mm
4 Conductor.
129(L)
x 77(W)
x 40(H)
[mm]
Black 94V0 Polycarbonate
Other94V0
cablePolycarbonate
and connectors are available.
Black
18 AWG 1,500mm 4 Conductor.
18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Other cable and connectors are available.
IEC320
C14 (F)
C8 (N)
C18 (Q)
IEC320
IEC320
IEC320
Specify the input IEC320
configuration Code
in your Order.
IEC320
IEC320
C14 (F)
C8 (N)
C18 (Q)
Part(F)Number Key
C14
C8 (N)
C18 (Q)
Specify the input configuration Code in your Order.
JMW190
Specify the input
configuration Code in your Order.
Part Number Key
Part Number Key
Product
Family Name
JMW190
JMW190
KB
12
XX
X
XX
Design Revision
KB Change
KB
Volt12(DC)
12
Connector
XXNumber
XX
Input Configuration
X
X
Customer
XXNumber
XX
Product Family Name
Product Family Name
Design Revision Change
Design Revision Change
Volt (DC)
Volt (DC)
Connector Number
Connector Number
Input Configuration
Input Configuration
Customer Number
Customer Number
BridgePower Corporation
BridgePower Corporation
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
Tel : +82-31-299-1234 Fax : +82-31-224-0566
Tel : +82-31-299-1234 Fax : +82-31-224-0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
M9
M9
M9
Medical / Switching Mode Power Supply
JMW1100KB Universal 100 Watt Series
JMW1100KB Universal 100 Watt Series
Medical / Switching Mode Power Supply
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
••Single
Output
100W Input
100-240
VactoUniversal
Meets "ENERGY
Program
••Regulated
OutputSTAR"
with Low
RippleRequirements
SingleSafety
Output
to 100W
••Meets
Agency
Requirements
Regulated
Output
with Low Ripple
••Impact
Resistant
Polycarbonate
Enclosure
Meets Safety
AgencyDesigns
Requirements
••Modified
and Custom
Also Available
Impact Resistant
Polycarbonate Enclosure
••Desktop
Style
• Modified and Custom Designs Also Available
• Desktop Style
Model
Output Voltage
Maximum
Maximum
Ripple
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
JMW1100-KB-12-XX-X-XX
Output
12Voltage
Maximum
7.50
Maximum
90.0
Ripple
120
JMW1100-KB-13-XX-X-XX
DC
13 (V)
Current
6.92 (A)
Watts
90.0 (W)
Vp-p130
max. (mV)
JMW1100-KB-12-XX-X-XX
JMW1100-KB-15-XX-X-XX
JMW1100-KB-13-XX-X-XX
JMW1100-KB-16-XX-X-XX
12
15
13
16
7.50
6.40
6.92
6.00
90.0
96.0
90.0
96.0
120
150
130
160
JMW1100-KB-15-XX-X-XX
JMW1100-KB-18-XX-X-XX
JMW1100-KB-16-XX-X-XX
JMW1100-KB-19-XX-X-XX
15
18
16
19
6.40
5.60
6.00
5.20
96.0
100.8
96.0
98.8
150
180
160
190
JMW1100-KB-18-XX-X-XX
JMW1100-KB-24-XX-X-XX
JMW1100-KB-19-XX-X-XX
JMW1100-KB-48-XX-X-XX
18
24
19
48
5.60
4.20
5.20
2.10
100.8
100.8
98.8
100.8
180
240
190
480
JMW1100-KB-24-XX-X-XX
JMW1100-KB-48-XX-X-XX
24
48
4.20
2.10
100.8
100.8
240
480
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line
Frequency
Input
Specification
47 to 63 Hz
Leakage
Current
General
Specification
Less than 100uA
InputCurrent
Voltage Range
Input
100max.
to 240VAC
-10%,
+10%
3.0A
at 90VAC
Input
TopologyWithstand
Dielectric
SwitchingPrimary
- Fixed -Frequency
5,656VDC
SecondaryFlyback
Line Frequency
Protection
47 to 63
Hz
Internal
Primary
Current Fuse, Inrush Limiting
Input Current
3.0A max. at 90VAC Input
Protection
Output
Specification
Internal Primary Current Fuse, Inrush Limiting
Line & Load Regulation
Line Voltage
+/- 1%
(at
End of Specification
Cable)
Output
Load Voltage
+/- 5%
Switching - Fixed Frequency Flyback
Leakage Current
Less thanPrimary
100uA - F.G
2,545VDC
Dielectric Withstand
5,656VDC
Primary--F.G
Secondary
500VDC
Secondary
2,545VDC
- F.G
-30
˚C to 85 Primary
˚C
Storage Temperature
500VDC Secondary
- F.G
Minimum
Average Efficyency
in Active Mode
Efficiency
Storage Temperature
Line & Load Regulation
Ripple
Line
Voltage
1%
Vp-p
max.
Efficiency
Hold-up
Time
Minimum
Average Efficyency in Active Mode
18ms
min. @115VAC
(at End of
Cable)
Transient
Response
Load for
Voltage
+/- 5%
0.5ms
50% Load change
Typ.
EMI
Complies
≥ 87% with EMC Directives
Ripple
Protection
1% Vp-p max.
Over-current
Protection (Hiccup)
Hold-up
Time
Max.
Power
in No-Load
≤18ms
0.5Wmin. @115VAC
0.5ms
for 50%
Load change Typ.
Short
Circuit
Protection
EMI
MTBF
Complies
with EMCHours
Directives
100,000
Calculated
Minimum.
Over-current Protection (Hiccup)
Max. Power
Approvals
andin No-Load
UL60601-1,
≤ 0.5W IEC/EN60601-1, K60950-1
Short Circuit Protection
MTBFStandards
Safety
100,000
Calculated Hours
Minimum.
EMC
: EN60601-1-1-2
/ EN55011
Transient Response
Protection
Environmental Specification
+/- 1%
≥-30
87%
˚C to 85 ˚C
Operating Temperature
0˚C to 40˚C with no derating
Approvals
and
Case
and Dimension
Relative
Humidity Specification
Environmental
5% to 95% non-condensing
Safety Standards
UL60601-1,
IEC/EN60601-1,
5.87(L)
x 3.37(W)
x 1.87(H) [in]K60950-1
EMC :xEN60601-1-1-2
/ EN55011
149(L)
85.5(W) x 47.5(H)
[mm]
Operating Temperature
Altitude
0 0˚C
- 10,000
feet
to 40˚C
with no derating
CaseMaterial
and Dimension
Case
5.87(L)
x 3.37(W)
x 1.87(H) [in]
Black
94V0
Polycarbonate
Relative Humidity
Cooling
5% to 95% non-condensing
Convectional
- Non vented case
Cord and Connectors
85.5(W) x447.5(H)
[mm]
18149(L)
AWGx1,500mm
Conductor.
Altitude
Cooling
Input
Configuration
0 - 10,000 feet
Case Material
Convectional - Non vented case
Cord and Connectors
Blackcable
94V0and
Polycarbonate
Other
connectors are available.
18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
IEC320
IEC320
C14 (F)
C8 (N)
C18 (Q)
IEC320the input configuration
IEC320
Specify
CodeIEC320
in your Order.
C14 Number
(F)
C8 (N)
C18 (Q)
Part
Key
JMW1100
Specify the input
configuration Code in your Order.
Part Number Key
Product Family Name
JMW1100
Product Family Name
KB
12
XX
X
XX
Design Revision Change
KB
Volt (DC)
12
Connector Number
XX
Input Configuration
X
Customer Number
XX
Design Revision Change
BridgePower Corporation
BridgePower Corporation
Volt (DC)
Connector Number
Input Configuration
Tel : +82-31-299-1234
Customer Number
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
Tel : +82-31-299-1234 Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M10
M10
Medical / Switching Mode Power Supply
BPM121S Universal 120 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 120W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM121-S-12-X-XX
12
10.00
120.0
120
BPM121-S-15-X-XX
15
8.00
120.0
150
BPM121-S-18-X-XX
18
6.67
120.1
180
BPM121-S-24-X-XX
24
5.00
120.0
240
Model
Medical
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
3.0A max. at 90VAC Input
Dielectric Withstand
5,656VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Half bridge
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60950-1, IEC/EN60950-1, K60950-1
Safety Standards
EMC : EN55022 / 55024 / 61000
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
8.2(L) x 2.5(W) x1.6(H) [in]
209.4(L) x 64.4(W) x 41.5(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG or 18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPM121
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M11
Medical / Switching Mode Power Supply
BPM131S Universal 130 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 130W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM131-S-12-X-XX
12
10.80
129.6
120
BPM131-S-15-X-XX
15
8.67
130.1
150
BPM131-S-18-X-XX
18
7.20
129.6
180
BPM131-S-24-X-XX
24
5.40
129.6
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
3.0A max. at 90VAC Input
Dielectric Withstand
5,656VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Half bridge
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
8.2(L) x 2.5(W) x1.6(H) [in]
209.4(L) x 64.4(W) x 41.5(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG or 18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPM131
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M12
Medical / Switching Mode Power Supply
BPM150S Universal 150 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 150W
• Regulated Output with Low Ripple
• Meets Medical Safety Agency Requirements
• CE Compliant
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM-150-S-12-X-XX
12
12.50
150.0
120
BPM-150-S-15-X-XX
15
10.00
150.0
150
BPM-150-S-18-X-XX
18
8.30
149.4
180
BPM-150-S-24-X-XX
24
6.25
150.0
240
Model
Medical
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Half bridge
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
3.0A max. at 90VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
5,656VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Line & Load Regulation
Line Regulation
+/- 1%
Efficiency
87% min
(at End of Cable)
Load Regulation
+/- 5%
Hold-up Time
18ms min. @120VAC
Ripple & Noise
1% Vp-p max.
EMI
Complies with EMC Directives
Transient Response
0.5ms for 50% Load change Typ.
MTBF
100,000Calculated Hours Minimum.
Over-current Protection (Hiccup)
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Short Circuit Protection
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Case and Dimension
8.2(L) x 2.5(W) x1.6(H) [in]
Protection
Environmental Specification
209.4(L) x 64.4(W) x 41.5(H) [mm]
Operating Temperature
0˚C to 40˚C with no derating
Case Material
Black 94V0 Polycarbonate
Relative Humidity
5% to 95% non-condensing
Cord and Connectors
T.B.D
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPM150
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M13
Medical / Switching Mode Power Supply
BPM200S Universal 200 Watt Series
• 100-240 Vac Universal Input
• Meets "ENERGY STAR" Program Requirements
• Single Output to 200W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Impact Resistant Polycarbonate Enclosure
• Modified and Custom Designs Also Available
• Desktop Style
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
BPM200-S-12-X-XX
12
16.70
200.4
120
BPM200-S-15-X-XX
15
13.35
200.3
150
BPM200-S-18-X-XX
18
11.15
200.7
180
BPM200-S-24-X-XX
24
8.35
200.4
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Line Frequency
47 to 63 Hz
Leakage Current
Less than 100uA
Input Current
3.5A max. at 90VAC Input
Dielectric Withstand
5,656VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Switching - Half bridge
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
-30 ˚C to 85 ˚C
Efficiency
Minimum Average Efficyency in Active Mode
≥ 87%
Ripple & Noise
1% Vp-p max.
Hold-up Time
18ms min. @115VAC
Transient Response
0.5ms for 50% Load change Typ.
EMI
Complies with EMC Directives
Protection
Over-current Protection (Hiccup)
Max. Power in No-Load
≤ 0.5W
Short Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Approvals and
UL60601-1, IEC/EN60601-1, K60950-1
Safety Standards
EMC : EN60601-1-1-2 / EN55011
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case and Dimension
8.27(L) x 3.19(W) x 1.83(H) [in]
210(L) x 81(W) x 46.4(H) [mm]
Altitude
0 - 10,000 feet
Case Material
Black 94V0 Polycarbonate
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG or 18 AWG 1,500mm 4 Conductor.
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPM200
Product Family Name
S
12
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
M14
Medical / Switching Mode Power Supply
Medical / Switching Mode Power Supply
BPM350S Universal 350 Watt Series
BPM350S Universal 350 Watt Series
• 100-240 Vac Universal Input
100-240
Vac to
Universal
• Single
Output
350W Input
Output
to 350W
• Single
Regulated
Output
with Low Ripple
• Regulated
Output
with
Low Ripple
Meets Safety
Agency
Requirements
Meets Safety
Agency
Requirements
• Impact
Resistant
Polycarbonate
Enclosure
• Impact
Resistant
Polycarbonate
Enclosure
Modified
and Custom
Designs Also
Available
and Custom Designs Also Available
• Modified
Desktop Style
• Desktop Style
Output Voltage
Output
DC Voltage
(V)
Model
Model
BPM350-S-12-X-XX
BPM350-S-12-X-XX
BPM350-S-15-X-XX
BPM350-S-15-X-XX
BPM350-S-18-X-XX
BPM350-S-18-X-XX
BPM350-S-24-X-XX
BPM350-S-24-X-XX
Maximum
Maximum
Watts (W)
DC12(V)
Maximum
Maximum
Current
(A)
Current
25.00(A)
Watts
300.0(W)
Ripple
Vp-pRipple
max. (mV)
Vp-p max.
120 (mV)
12
15
15
18
18
24
25.00
20.00
20.00
19.40
19.40
14.58
300.0
300.0
349.2
120
150
150
180
24
14.58
349.2
349.9
349.9
180
240
240
Medical
Input Specification
General Specification
InputVoltage
Specification
Input
Range
100 to 240VAC -10%, +10%
General Specification
Topology
Switching - Half bridge
InputFrequency
Voltage Range
Line
100toto63240VAC
-10%, +10%
47
Hz
TopologyCurrent
Leakage
Switching
- Half bridge
Less
than 100uA
Line Frequency
Input
Current
47 tomax.
63 Hzat 90VAC Input
5.0A
Leakage Current
Dielectric
Withstand
Less than 100uA
5,656VDC
Primary - Secondary
Input Current
Protection
5.0A max.
at 90VAC
InputFuse, Inrush Limiting
Internal
Primary
Current
Dielectric Withstand
5,656VDC Primary
Primary -- F.G
Secondary
2,150VDC
Protection
Internal Primary Current Fuse, Inrush Limiting
2,150VDC
Primary --F.G
500VDC
Secondary
F.G
Storage Temperature
500VDC
- F.G
-30
˚C toSecondary
85 ˚C
+/- 1%
Storage Temperature
Efficiency
-3085%
˚C to 85 ˚C
≥
+/- 5%
1%
+/-
Efficiency
≥ 85%
Output Specification
Output
Specification
Line
& Load
Regulation
Line Voltage
Line
& Load
Regulation
(at End
of Cable)
Line Voltage
Load
Voltage
(at End of Cable)
Ripple
Load
Voltage
1%
Vp-p
max.
+/- 5%
Hold-up Time
18ms min. @115VAC
Ripple Response
Transient
1% Vp-p
0.5ms
formax.
50% Load change Typ.
Hold-up Time
EMI
18ms min.with
@115VAC
Complies
EMC Directives
Transient Response
Protection
0.5ms for 50%Protection
Load change
Typ.
Over-current
(Hiccup)
EMI
Complies with EMC Directives
Protection
Over-current
Protection (Hiccup)
Short
Circuit Protection
MTBF
100,000 Calculated Hours Minimum.
Short Circuit Protection
MTBF
Approvals
and
100,000 Calculated
Hours Minimum.
UL60601-1,
IEC/EN60601-1,
K60950-1
Approvals
and
Safety
Standards
UL60601-1,
IEC/EN60601-1,
K60950-1
EMC
: EN60601-1-1-2
/ EN55011
EMC : EN60601-1-1-2
/ EN55011
12.06(L)
x 5.23(W) x2.47(H)
[in]
Environmental Specification
Environmental
Specification
Operating
Temperature
0˚C to 40˚C with no derating
Safetyand
Standards
Case
Dimension
Operating
Temperature
Relative
Humidity
0˚C
40˚C non-condensing
with no derating
5% to 95%
Case and Dimension
12.06(L) xx 133(W)
5.23(W)xx2.47(H)
[in]
306.5(L)
62.8(H) [mm]
Relative Humidity
Altitude
to 95%feet
non-condensing
05%- 10,000
Case Material
306.5(L)
x 133(W)
x 62.8(H) [mm]
Black
94V0
Polycarbonate
Altitude
Cooling
0 - 10,000 feet- Non vented case
Convectional
Case Material
Cord
and Connectors
Black
94V01,500mm
Polycarbonate
16
AWG
6 Conductor.
Cooling
Convectional - Non vented case
Cord and Connectors
16 AWG
1,500mm
6 Conductor.
Other
cable
and connectors
are available.
Other cable and connectors are available.
Input Configuration
Input Configuration
IEC320
IEC320
C14
(F)
C14 (F) the input configuration Code in your Order.
Specify
Specify the input configuration Code in your Order.
Part Number Key
Part NumberBPM350
Key
BPM350
Product Family Name
Product Family Name
S
S
Single Output
Single Output
BridgePower Corporation
BridgePower Corporation
12
12
Volt (DC)
Volt (DC)
X
X
Input Configuration
Input Configuration
XX
XX
Customer Number
Customer Number
Tel : +82-31-299-1234 Fax : +82-31-224-0566
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
M15
M15
Battery Charger
EXTERNAL Power Supplies
BATTERY CHARGER
Standard / Custom Design Battery Charger
Lithium ion / Polymer Battery Fast Charger
Ni_Cd/Ni_MH Battery Fast Charger
Sealed Lead Acid Battery Fast Charger
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B
Standard Design Battery Charger
BL607 Series Li-ion/Polymer Fast Chargers
• Universal Input 100 to 250VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Li-ion/Polymer Battery Life
• Automatic Constant Current & Constant Voltage
• Dual Color LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Fast Charge Voltage
Fast Charge Current
Cut-off Current
[V]
[A]
[A]
[W]
1
4.20
1.00
0.10
4.20
2
8.40
0.80
0.08
6.72
Model
Number of Cells
BL607-04-010-XXXXXX
BL607-08-008-XXXXXX
Input Specification
Maximum Watts
General Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Topology
Switching - Battery Charger
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.4A max. at 110VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Storage Temperature
-30 ˚C to 85 ˚C
Hold-up Time
16ms min. @115VAC
MTBF
61,000 Calculated Hours Minimum.
Battery Type
Lithium Ion/Polymer
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Charging Method
Constant Current and Constant Voltage
Standards
K60950/K60335-1,2
Case and Dimension
LP4N
Fsat Charge Voltage
4.2V +/-0.03V / Cell
Threshold Voltage
2.5V +/-0.03V / Cell
Protection
Over-current Protection (Hiccup)
95(L) x 54(W) x 32(H) [mm]
Short Circuit Protection
3.74(L) x 2.13(W) x 1.26(H) [in]
LED Indicators
Battery charger
Output Specification
EMC : EN55022/55024/61000
Red : Charging
Case Material
Black 94V0 Polycarbonate
Green : Fully Charge
Cord and Connectors
2 Conductor, 18AWG
Environmental Specification
Other cable and connectors are available.
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Input Configuration
SHAVER
Europe/Korea
C8 (N)
(M)
Specify the input configuration Code in your Order.
Part Number Key
BL
Type
607
08
008
Family Related
Design
Charge Constant
Voltage
Charge Constant
Current
BridgePower Corporation
51
03
F
K
Miscellan
Standard Output
Cord Options
Standard Input
Cord Options
Design No.
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B1
Standard Design Battery Charger
BL600 Series Li-ion Fast Chargers
• Universal Input 100 to 250VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Li-ion/Polymer Battery Life
• Automatic Constant Current & Constant Voltage
• Single Color 2LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Thermistor
Fast Charge Voltage
Fast Charge Current
Cut-off Current
Required
[V]
[A]
[A]
[W]
2
YES / NO
8.40
1.70
0.17
6.30
BL600-X-03-140-XXXXX
3
YES / NO
12.60
1.40
0.14
12.60
BL600-X-04-100-XXXXX
4
YES / NO
16.80
1.00
0.10
15.12
Model
Number of Cells
BL600-X-02-170-XXXXX
Maximum Watts
X : (Safety Timer) and (with or without Thermistor)
1 = 3hr / No Thermistor
2 = 6hr / No Thermistor
3 = 9hr / No Thermistor
5 = 3hr / Thermistor
6 = 6hr / Thermistor
7 = 9hr / Thermistor
Input Specification
General Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Topology
Switching - Battery Charger
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.8A max. at 110VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
4,242VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Battery Type
Lithium Ion/Polymer
Hold-up Time
16ms min. @115VAC
Charging Method
Constant Current and Constant Voltage
MTBF
61,000 Calculated Hours Minimum.
Fsat Charge Voltage
4.2V +/-0.03V / Cell
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Protection
Over-current Protection (Hiccup)
Standards
K60950/K60335-1,2
LED Indicators
Amber, Green 2LED
Case and Dimension
LP6 - Desktop
Short Circuit Protection
EMC : EN55022/55024/61000
104(L) x 66(W) x 37(H) [mm]
Environmental Specification
4.2(L) x 2.6(W) x 1.46(H) [in]
Operating Temperature
0˚C to 40˚C with no derating
Case Material
Black 94V0 Polycarbonate
Relative Humidity
5% to 95% non-condensing
Cord and Connectors
Without thermistor 2 conductor, 18 AWG,
Altitude
0 - 10,000 feet
Ault #3 connector,
Cooling
Convectional - Non vented case
With thermistor 3 conductor, 20 AWG,
Ault #21 connector.
Input Configuration
Other cable and connectors are available.
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BL
Type
600
1
Family Related
Design
Timer &
Thermistor Option
BridgePower Corporation
02
Number of Cells
170
03
01
K
Charge Constant
Miscellaneous
Cord Options
Standard Input
Cord Options
Design No.
Current
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B2
Standard Design Battery Charger
JBL702A Series Li-ion/Polymer Fast Chargers
• Universal Input 100 to 240VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Li-ion/Polymer Battery Life
• Automatic Constant Current & Constant Voltage
• Dual Color LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Fast Charge Voltage
Fast Charge Current
Cut-off Current
[V]
[A]
[A]
[W]
4.20
2.00
0.20
8.40
2
8.40
2.00
0.20
16.80
3
12.60
1.50
0.15
18.90
JBL702A-16-120-XXXXXX
4
16.80
1.20
0.10
20.16
JBL702A-21-100-XXXXXX
5
21.00
1.00
0.10
21.00
Model
Number of Cells
JBL702A-04-200-XXXXXX
1
JBL702A-08-200-XXXXXX
JBL702A-12-150-XXXXXX
Input Specification
Maximum Watts
General Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Topology
Switching - Battery Charger
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
1.0Amax at 110VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
4,242VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
500VDC Secondary - F.G
Storage Temperature
-30 ˚C to 85 ˚C
Battery Type
Lithium Ion/Polymer
Hold-up Time
16ms min. @115VAC
Charging Method
Constant Current and Constant Voltage
MTBF
61,000 Calculated Hours Minimum.
Fsat Charge Voltage
4.2V +/-0.03V / Cell
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Threshold Voltage
2.5V +/-0.03V / Cell
Standards
K60950/K60335-1,2
Protection
Over-current Protection (Hiccup)
Case and Dimension
JEC#18 - Desktop
EMC : EN55022/55024/61000
Short Circuit Protection
LED Indicators
Red : Charging
114(L) x 60(W) x 35(H) [mm]
Green : Fully Charge
4.49(L) x 2.36(W) x 1.38(H) [in]
Environmental Specification
Case Material
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Battery charger
Output Specification
Black 94V0 Polycarbonate
Cord and Connectors
2 Conductor, 18AWG
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
JBL
Type
702A
08
Family Related
Design
Charge Constant
Voltage
BridgePower Corporation
200
01
02
Custom
Charge Constant
Standard Output
Current
(marking,cord,etc). Cord Options
Tel : +82-31-299-1234
F
K
Standard Input
Cord Options
Design No.
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B3
Standard Design Battery Charger
JBL745-1 Series Li-ion/Polymer Fast Chargers
• Universal Input 100 to 240VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Li-ion/Polymer Battery Life
• Automatic Constant Current & Constant Voltage
• Dual Color LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Fast Charge Voltage
Fast Charge Current
Cut-off Current
[V]
[A]
[A]
[W]
2
8.40
5.00
0.5 +/-10%
42.00
JBL745-1-12-330-XXXXXX
3
12.60
3.30
0.3 +/-10%
42.00
JBL745-1-16-250-XXXXXX
4
16.80
2.50
0.2 +/-10%
42.00
JBL745-1-21-200-XXXXXX
5
21.00
2.00
0.2 +/-10%
42.00
JBL745-1-25-170-XXXXXX
6
25.20
1.70
0.15 +/-10%
42.80
JBL745-1-29-150-XXXXXX
7
29.40
1.50
0.15 +/-10%
44.10
Model
Number of Cells
JBL745-1-08-500-XXXXXX
Input Specification
Maximum Watts
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Battery Charger
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
1.0Amax at 110VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
4,242VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Battery Type
Lithium Polymer or Lithium ion 2-7 Cells
Hold-up Time
16ms min. @115VAC
Charging Method
Constant Current and Constant Voltage
MTBF
61,000 Calculated Hours Minimum.
Fsat Charge Voltage
4.2V +/-0.03V / Cell
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Threshold Voltage
2.5V +/-0.03V / Cell
Standards
K60950/K60335-1,2
Protection
Over-current Protection (Hiccup)
Case and Dimension
JEC#21 - Desktop
EMC : EN55022/55024/61000
Short Circuit Protection
LED Indicators
Red : Charging
150(L) x 65(W) x 35(H) [mm]
Green : Fully Charge
5.9(L) x 2.56(W) x 1.38(H) [in]
Environmental Specification
Case Material
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Black 94V0 Polycarbonate
Cord and Connectors
2 Conductor, 18AWG
Other cable and connectors are available.
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
JBL
745
Type
1
16
Family Related
Battery
Design
Type
Charge Constant
Voltage
BridgePower Corporation
250
51
02
Custom
Charge Constant
Standard Output
Current
Cord Options
(marking,cord,etc.)
Tel : +82-31-299-1234
F
K
Standard Input
Cord Options
Design No.
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B4
Standard Design Battery Charger
BPL910S Series Li-ion/Polymer Fast Chargers
• Universal Input 100 to 240VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Li-ion/Polymer Battery Life
• Automatic Constant Current & Constant Voltage
• Dual Color LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Fast Charge Voltage
Fast Charge Current
Cut-off Current
[V]
[A]
[A]
[W]
4.20
1.50
0.15
6.30
2
8.40
1.50
0.15
12.60
3
12.60
1.20
0.12
15.12
4
16.80
1.00
0.10
16.80
Model
Number of Cells
BPL910-S-04-X-XX
1
BPL910-S-08-X-XX
BPL910-S-12-X-XX
BPL910-S-16-X-XX
Input Specification
Maximum Watts
General Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Topology
Switching - Battery Charger
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.8Amax at 110VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Storage Temperature
-30 ˚C to 85 ˚C
Hold-up Time
16ms min. @115VAC
MTBF
61,000 Calculated Hours Minimum.
Battery Type
Lithium Ion/Polymer
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Charging Method
Constant Current and Constant Voltage
Standards
K60950/K60335-1,2
Case and Dimension
LP4N
Fsat Charge Voltage
4.2V +/-0.03V / Cell
Threshold Voltage
2.5V +/-0.03V / Cell
Protection
Over-current Protection (Hiccup)
95(L) x 54(W) x 32(H) [mm]
Short Circuit Protection
3.74(L) x 2.13(W) x 1.26(H) [in]
LED Indicators
Battery charger
Output Specification
EMC : EN55022/55024/61000
Red : Charging
Case Material
Black 94V0 Polycarbonate
Green : Fully Charge
Cord and Connectors
2 Conductor, 20AWG
Environmental Specification
Other cable and connectors are available.
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Input Configuration
IEC320
IEC320
C14 (F)
C8 (N)
Specify the input configuration Code in your Order.
Part Number Key
BPL910
Product Family Name
S
04
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B5
Standard Design Battery Charger
BPL775S Series Li-ion/Polymer Fast Chargers
• Universal Input 100 to 240VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Li-ion/Polymer Battery Life
• Automatic Constant Current & Constant Voltage
• Dual Color LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Fast Charge Voltage
Fast Charge Current
Cut-off Current
[V]
[A]
[A]
[W]
2
8.40
6.00
0.60+/-10%
50.40
BPL775-S-12-F-XX
3
12.60
5.00
0.50+/-10%
63.00
BPL775-S-16-F-XX
4
16.80
4.50
0.45+/-10%
75.60
BPL775-S-21-F-XX
5
21.00
3.50
0.35+/-10%
73.50
BPL775-S-25-F-XX
6
25.20
3.00
0.30+/-10%
75.60
BPL775-S-29-F-XX
7
29.40
2.50
0.25+/-10%
73.50
BPL775-S-42-F-XX
10
42.00
1.80
0.30+/-10%
75.60
Model
Number of Cells
BPL775-S-08-F-XX
Input Specification
Maximum Watts
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Battery Charger
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
2.0Amax at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Storage Temperature
-30 ˚C to 85 ˚C
Output Specification
Hold-up Time
16ms min. @115VAC
MTBF
100,000 Calculated Hours Minimum.
UL60950-1, IEC/EN60950-1,
Battery Type
Lithium Ion/Polymer
Approvals and Safety
Charging Method
Constant Current and Constant Voltage
Standards
Fsat Charge Voltage
4.2V +/-0.03V / Cell
K60950/K60335-1,2
EMC : EN55022/55024/61000
Threshold Voltage
2.5V +/-0.03V / Cell
Protection
Over-current Protection (Hiccup)
Case and Dimension
LP7 - Desktop
LED Indicators
Red : Charging
Case Material
Black 94V0 Polycarbonate
Green : Fully Charge
Cord and Connectors
4 Conductor, 18AWG
5.08(L) x 3.05(W) x 1.59(H) [in]
Short Circuit Protection
129(L) x 77(W) x 40(H) [mm]
Environmental Specification
Other cable and connectors are available.
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPL775
Product Family Name
S
08
F
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B6
Standard Design Battery Charger
BPL150S Series Li-ion/Polymer Fast Chargers
• Universal Input 100 to 240VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Li-ion/Polymer Battery Life
• Automatic Constant Current & Constant Voltage
• Dual Color LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Fast Charge Voltage
Fast Charge Current
Cut-off Current
[V]
[A]
[A]
[W]
2
8.40
12.00
1.20+/-10%
100.80
BPL150-S-12-F-XX
3
12.60
10.00
1.00+/-10%
126.00
BPL150-S-16-F-XX
4
16.80
8.00
0.80+/-10%
134.40
BPL150-S-21-F-XX
5
21.00
7.00
0.70+/-10%
147.00
BPL150-S-25-F-XX
6
25.20
6.00
0.60+/-10%
151.20
BPL150-S-29-F-XX
7
29.40
5.00
0.50+/-10%
147.00
BPL150-S-42-F-XX
10
42.00
3.50
0.35+/-10%
147.00
Model
Number of Cells
BPL150-S-08-F-XX
Input Specification
Maximum Watts
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Battery Charger
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
3.0Amax at 90VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Storage Temperature
-30 ˚C to 85 ˚C
Hold-up Time
16ms min. @115VAC
MTBF
100,000 Calculated Hours Minimum.
UL60950-1, IEC/EN60950-1,
Battery Type
Lithium Ion/Polymer
Approvals and Safety
Charging Method
Constant Current and Constant Voltage
Standards
Fast Charge Voltage
4.2V +/-0.03V / Cell
Battery charger
Output Specification
K60950/K60335-1,2
EMC : EN55022/55024/61000
Threshold Voltage
2.5V +/-0.03V / Cell
Protection
Over-current Protection (Hiccup)
Case and Dimension
8.27(L) x 3.19(W) x 1.83(H) [in]
Short Circuit Protection
Case Material
Black 94V0 Polycarbonate
LED Indicators
Red : Charging
Cord and Connectors
4 Conductor, 18AWG
210(L) x 81(W) x 46.4(H) [mm]
Green : Fully Charge
Other cable and connectors are available.
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Input Configuration
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BPL150
Product Family Name
S
08
F
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B7
Standard Design Battery Charger
BCM Series NiCd/NiMH Fast Chargers
• Universal Input 100 to 250VAC
• Optimizes Battery Life with Microcontroller
• Charges NiCd/NiMH 3 - 12 cell Batteries
• Polycarbonate Enclosure Desktop Style
• LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Normal Charge Voltage
Fast Charge Current
Safety Timer
[V]
[A]
[hr]
[W]
4.5 - 9.0
0.8 - 1.5
1.5 - 9.0
13.50
5 - 10
7.5 - 15.0
0.6 - 1.2
1.5 - 8.0
18.00
8 - 12
12.0 - 18.0
0.6 - 1.0
1.5 - 8.0
18.00
Model
Number of Cells
BCM-X1-306-AAA-XXXXX
3-6
BCM-X1-306-AAA-XXXXX
BCM-X1-306-AAA-XXXXX
Maximum Watts
X1 : Safety Timer 1 = NiCd / 1.5hr, 2 = NiCd / 3hr, 3 = NiCd / 6hr, 4 = NiCd / 9hr
5 = NiMH / 1.5hr, 6 = NiMH / 3hr, 7 = NiMH / 6hr, 8 = NiMH / 9hr
AAA : Fast Charge Current (060=0.6A, 080=0.8A, 100=1.0A, 120=1.2A, 150=1.5A)
Input Specification
Environmental Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Operating Temperature
Line Frequency
47 to 63 Hz
Relative Humidity
5% to 95% non-condensing
Input Current
0.7Amax at 110VAC Input
Altitude
0 - 10,000 feet
Protection
Internal Primary Current Fuse, Inrush Limiting
Cooling
Convectional - Non vented case
Battery Type
NiCd/NiMH 3-12 Cells , NTC:10Kohm/25°C
Topology
Switching - Battery Charger
Charging Method
Constant Current
Leakage Current
Less than 250uA
Threshold Voltage
1.0V +/-0.2V / Cell
Dielectric Withstand
Normal Charge Voltage
>1.5V / Cell
Mornitoring Fully Charge
-△V, 0△V, Vmax, Tmax, △T/△t … etc
Protection
Over-current Protection (Hiccup)
Storage Temperature
Short Circuit Protection
Hold-up Time
16ms min. @115VAC
ON : Charge
MTBF
61,000 Calculated Hours Minimum.
OFF : Low/High Temp Charge
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Blink : Low/High Temp Faulty
Standards
K60950/K60335-1,2
Case and Dimension
JEC#21 - Desktop
Output Specification
LED Indicator #1 (Green)
LED Indicator #2 (Amber)
0˚C to 40˚C with no derating
General Specification
4,242VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
500VDC Secondary - F.G
-30 ˚C to 85 ˚C
ON : Charge
EMC : EN55022/55024/61000
OFF : Battery Absent
Blink : Low/High Temp Faulty
150(L) x 65(W) x 35(H) [mm]
Input Configuration
5.9(L) x 2.56(W) x 1.38(H) [in]
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
2 Conductor, 18AWG
Other cable and connectors are available.
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BCM
5
Family
Related
306
150
Type and
Number
Timer
of Cells
Charge Constant
Current
BridgePower Corporation
03
01
K
Custom
Standard Output
Cord Options
(marking,cord,etc.)
Design No.
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B8
Standard Design Battery Charger
BCW Series NiCd/NiMH Fast Chargers
• Universal Input 100 to 250VAC
• Optimizes Battery Life with Microcontroller (BQ2003)
• Charges NiCd/NiMH 5 - 11 cell Batteries
• Polycarbonate Enclosure Desktop Style
• LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Normal Charge Voltage
Fast Charge Current
Float Change Current
Time Shut Off
[V]
[A]
[A]
Hours [W]
5
7.50
0.6 - 1.5
1.5 - 9.0
1.5 - 6.0
BCW-X1-06-AAA-XXXXX
6
9.00
0.6 - 1.5
1.5 - 8.0
1.5 - 6.0
BCW-X1-07-AAA-XXXXX
7
10.50
0.6 - 1.5
1.5 - 8.0
1.5 - 6.0
BCW-X1-08-AAA-XXXXX
8
12.00
0.6 - 1.5
1.5 - 8.1
1.5 - 6.0
BCW-X1-09-AAA-XXXXX
9
13.50
0.6 - 1.5
1.5 - 8.2
1.5 - 6.0
BCW-X1-10-AAA-XXXXX
10
15.00
0.6 - 1.5
1.5 - 8.3
1.5 - 6.0
BCW-X1-11-AAA-XXXXX
11
16.50
0.6 - 1.5
1.5 - 8.4
1.5 - 6.0
Model
Number of Cells
BCW-X1-05-AAA-XXXXX
X1 : Time Shut Off-Hours (1=NiCd1.5hr, 2=NiCd 3hr, 3=NiCd 6hr, 5=NiMH 1.5hr, 6=NiMH 3hr,
AAA : Fast Charge Current (060=0.6A, 080=0.8A, 100=1.0A, 120=1.2A, 150=1.5A)
Input Specification
Environmental Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Operating Temperature
Line Frequency
47 to 63 Hz
Relative Humidity
5% to 95% non-condensing
Input Current
0.625Amax at 120VAC Input
Altitude
0 - 10,000 feet
Protection
Internal Primary Current Fuse, Inrush Limiting
Cooling
Convectional - Non vented case
Battery Type
NiCd/NiMH 5-11 Cells
Topology
Switching - Battery Charger
Charging Method
Constant Current
Leakage Current
Less than 250uA
Threshold Voltage
1.0V +/-0.2V / Cell
Dielectric Withstand
Normal Charge Voltage
>1.5V / Cell
General Specification
4,242VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
Fast Charge Voltage
0.6 - 1.5A
Mornitoring Fully Charge
-△V, 0△V, Vmax … etc
Storage Temperature
Protection
Over-current Protection (Hiccup)
Hold-up Time
16ms min. @115VAC
Short Circuit Protection
MTBF
61,000 Calculated Hours Minimum.
Fast Charge : ON
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Float Charge : Blinking
Standards
K60950/K60335-1,2
LED Indicators
Battery charger
Output Specification
0˚C to 40˚C with no derating
500VDC Secondary - F.G
-30 ˚C to 85 ˚C
EMC : EN55022/55024/61000
Case and Dimension
LP7-Desktop
129(L) x 77(W) x 40(H) [mm]
Input Configuration
5.8(L) x 3.05(W) x 1.59(H) [in]
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
2 Conductor, 18AWG
Other cable and connectors are available.
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BCW
5
Family
Related
7
150
Type and
Number
Timer
of Cells
Charge Constant
Current
BridgePower Corporation
03
01
K
Custom
Standard Output
Cord Options
(marking,cord,etc.)
Design No.
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B9
Standard Design Battery Charger
JBN730 Series NiCd/NiMH Fast Chargers
• Universal Input 100 to 240VAC
• Optimizes Battery Life with Microcontroller
• Charges NiCd/NiMH 3 - 12 cell Batteries
• Polycarbonate Enclosure Desktop Style
• Dual Color LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Normal Charge Voltage
Fast Charge Current
Trickle Charge Current
Safety Maximum
[V]
[A]
[A]
Time [hr]
3
4.50
0.6 - 2.2
0.1 - 0.2
1.5 - 8.0
JBN730-A5-004-AAA-XXXXX
4
6.00
0.6 - 2.2
0.1 - 0.2
1.5 - 8.0
JBN730-A5-005-AAA-XXXXX
5
7.50
0.6 - 2.2
0.1 - 0.2
1.5 - 8.0
JBN730-A5-006-AAA-XXXXX
6
9.00
0.6 - 2.2
0.1 - 0.2
1.5 - 8.0
JBN730-A5-007-AAA-XXXXX
7
10.50
0.6 - 2.0
0.1 - 0.2
1.5 - 8.0
JBN730-A5-008-AAA-XXXXX
8
12.00
0.6 - 1.8
0.1 - 0.2
1.5 - 8.0
JBN730-A5-009-AAA-XXXXX
9
13.50
0.6 - 1.5
0.1 - 0.2
1.5 - 8.0
JBN730-A5-010-AAA-XXXXX
10
15.00
0.6 - 1.5
0.1 - 0.2
1.5 - 8.0
JBN730-A5-011-AAA-XXXXX
11
16.50
0.6 - 1.2
0.1 - 0.2
1.5 - 8.0
JBN730-A5-012-AAA-XXXXX
12
18.00
0.6 - 1.0
0.1 - 0.2
1.5 - 8.0
Model
Number of Cells
JBN730-A5-003-AAA-XXXXX
AAA : Fast Charge Current (080=0.8A, 100=1.0A, 150=1.5A, 180=1.8A, 200=2.0A, 220=2.2A …)
Input Specification
Environmental Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Operating Temperature
Line Frequency
47 to 63 Hz
Relative Humidity
5% to 95% non-condensing
Input Current
1.0Amax at 110VAC Input
Altitude
0 - 10,000 feet
Protection
Internal Primary Current Fuse, Inrush Limiting
Cooling
Convectional - Non vented case
Battery Type
NiCd/NiMH 3-12 Cells
Topology
Switching - Battery Charger
Charging Method
Constant Current
Leakage Current
Less than 250uA
Threshold Voltage
1.0V +/-10%
Dielectric Withstand
Normal Charge Voltage
>1.5V / Cell
Output Specification
0˚C to 40˚C with no derating
General Specification
4,242VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
Fast Charge Voltage
0.6 - 2.2A
Mornitoring Fully Charge
-△V, 0△V, Vmax, Tmax, △T/△t (Option - NTC)
Storage Temperature
Protection
Over-current Protection (Hiccup)
Hold-up Time
16ms min. @115VAC
Short Circuit Protection
MTBF
61,000 Calculated Hours Minimum.
LED Indicators
500VDC Secondary - F.G
-30 ˚C to 85 ˚C
Red : Charging
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Green : Fully Charge
Standards
K60950/K60335-1,2
Case and Dimension
JEC#18 Desktop
Flicker Red : Error
EMC : EN55022/55024/61000
Input Configuration
114(L) x 60(W) x 35(H) [mm]
4.49(L) x 2.36(W) x 1.38(H) [in]
IEC320
Case Material
C14 (F)
Cord and Connectors
Black 94V0 Polycarbonate
Without thermistor 2 Conductor, 18AWG
Specify the input configuration Code in your Order.
With thermistor 3 Conductor, 20AWG
Other cable and connectors are available.
Part Number Key
JBN
730A5
Type
006
220
02
K
01
Family Related
Number
Design
of Cells
Charge Constant
Current
Standard Output
Cord Options
Design No.
Custom (Markings, Cord Etc)
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B10
Standard Design Battery Charger
BA500 Series Sealed Lead Acid Fast Chargers
• Universal Input 100 to 250VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Battery Life with Microcontroller
• Charges Lead Acid Battery
• LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Battery Voltage
Fast Charge Current
Switchover Current
Fast Charge
Float Charge
[V]
[A]
[A]
Voltage [V]
Voltage [V]
[W]
BA500-06-100-XXXXX
6
1.00
0.2 +/-10%
7.35
6.90
7.35
BA500-12-050-XXXXX
12
0.50
0.1 +/-10%
14.70
13.80
7.35
BA500-24-030-XXXXX
24
0.30
0.05 +/-10%
29.40
27.60
8.82
Model
Input Specification
Maximum Watts
General Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Topology
Switching - Battery Charger
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.3A max. at 110VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse, Inrush Limiting
Storage Temperature
-30 ˚C to 85 ˚C
MTBF
61,000 Calculated Hours Minimum.
Output Specification
Lead Acid Battery
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Charging Method
Constant Current and Constant Voltage
Standards
K60950/K60335-1,2
Case and Dimension
LP4N
Threshold Voltage
>1.75V / Cell
Cycle Charge Voltage
2.45V +/-0.2V / Cell (as measure at PCB output)
EMC : EN55022/55024/61000
Float Charge Voltage
2.30V +/-0.2V / Cell (as measure at PCB output)
95(L) x 54(W) x 32(H) [mm]
Protection
Over-current Protection (Hiccup)
3.74(L) x 2.13(W) x 1.26(H) [in]
Short Circuit Protection
Case Material
Black 94V0 Polycarbonate
LED Indicator
RED : Charging
Cord and Connectors
2 Conductor, 18AWG, AULT#3 Connector.
GREEN : Fully Charge
Other cable and connectors are available.
Flickering RED : Error
Environmental Specification
Operating Temperature
0˚C to 40˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional - Non vented case
Input Configuration
IEC320
C8 (N)
N.America
Japan/China (B)
Europe/Korea
United
Australia
(M)
Kingdom (G)
(H)
Specify the input configuration Code in your Order.
Part Number Key
BA500
607
050
01
03
K
Family Related
Design
Battery Charge
Voltage
Charge Constant
Current
Miscellaneous
Standard Output Cord Option
Design No.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B11
Battery charger
Battery Type
Standard Design Battery Charger
BVL Series Sealed Lead Acid Fast Chargers
• Universal Input 100 to 250VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Battery Life
• Charges Lead Acid Battery
• LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Battery Voltage
Fast Charge Current
Switchover Current
Fast Charge
Float Charge
[V]
[A]
[A]
Voltage [V]
Voltage [V]
[W]
6
1.00
0.08 - 0.1
7.35
6.90
7.35
BVL-06-200-XXXXX
6
2.00
0.16 - 0.18
7.35
6.90
14.70
BVL-12-060-XXXXX
12
0.60
0.04 - 0.05
14.70
13.80
8.82
BVL-12-120-XXXXX
12
1.20
0.1 - 0.11
14.70
13.80
17.64
BVL-24-030-XXXXX
24
0.30
0.03 - 0.05
29.40
27.60
8.82
BVL-24-060-XXXXX
24
0.60
0.07 - 0.08
29.40
27.60
17.64
Model
BVL-06-100-XXXXX
Input Specification
Maximum Watts
Environmental Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Operating Temperature
Line Frequency
47 to 63 Hz
Relative Humidity
5% to 95% non-condensing
Input Current
0.8A - 0.35A (Lower current with higher voltage)
Altitude
0 - 10,000 feet
Protection
Internal Primary Current Fuse, Inrush Limiting
Cooling
Convectional - Non vented case
Battery Type
Lead Acid 6V/12V/24V
Topology
Switching - Battery Charger
Charging Method
Constant Current and Constant Voltage
Leakage Current
Less than 250uA
Threshold Voltage
>1.75V / Cell
Dielectric Withstand
Cycle Charge Voltage
7.35V / 14.7V / 29.4V
Output Specification
0˚C to 40˚C with no derating
General Specification
4,242VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
Float Charge Voltage
6.9V / 13.8V / 27.6V
Protection
Over-current Protection (Hiccup)
Storage Temperature
500VDC Secondary - F.G
Short Circuit Protection
Hold-up Time
16ms min. @115VAC
LED Indicator #1 (Green)
ON : Unit Energized
MTBF
61,000 Calculated Hours Minimum.
OFF : Unit De-Energized
Approvals and Safety
UL60950-1, IEC/EN60950-1,
LED Indicator #2 (Amber)
ON : Battery Discharged
Standards
K60950/K60335-1,2
-30 ˚C to 85 ˚C
OFF : Battery Charged
EMC : EN55022/55024/61000
Case and Dimension
LP6 - Desktop
104(L) x 66(W) x 37(H) [mm]
4.20(L) x 2.60(W) x 1.46(H) [in]
Case Material
Input Configuration
Black 94V0 Polycarbonate
Cord and Connectors
2 Conductor, 18AWG, AULT#3 Connector.
Other cable and connectors are available.
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BVL
6
120
01
03
K
Family Related
Design
Battery Charge
Voltage
Charge Constant
Current
Miscellaneous
Standard Output Cord Option
Design No.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B12
Standard Design Battery Charger
BVW Series Sealed Lead Acid Fast Chargers
• Universal Input 100 to 250VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Battery Life
• Charges Lead Acid Battery
• LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Battery Voltage
Fast Charge Current
Switchover Current
Fast Charge
Float Charge
[V]
[A]
[A]
Voltage [V]
Voltage [V]
[W]
BVW-06-380-XXXXX
6
3.80
0.205
7.35
6.90
28.00
BVW-12-225-XXXXX
12
2.25
0.165
14.70
6.90
33.00
BVW-12-400-XXXXX
12
4.00
0.800
14.70
13.80
59.00
BVW-24-125-XXXXX
24
1.25
0.120
29.40
27.60
37.00
Model
Input Specification
Maximum Watts
Environmental Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Operating Temperature
Line Frequency
47 to 63 Hz
Relative Humidity
5% to 95% non-condensing
Input Current
0.8A - 0.35A (Lower current with higher voltage)
Altitude
0 - 10,000 feet
Protection
Internal Primary Current Fuse, Inrush Limiting
Cooling
Convectional - Non vented case
Battery Type
Lead Acid 6V/12V/24V
Topology
Switching - Battery Charger
Charging Method
Constant Current and Constant Voltage
Leakage Current
Less than 250uA
Threshold Voltage
>1.75V / Cell
Dielectric Withstand
Cycle Charge Voltage
7.35V / 14.7V / 29.4V
Output Specification
0˚C to 40˚C with no derating
General Specification
Battery charger
4,242VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
Float Charge Voltage
6.9V / 13.8V / 27.6V
Protection
Over-current Protection (Hiccup)
Storage Temperature
500VDC Secondary - F.G
Short Circuit Protection
Hold-up Time
-30 ˚C to 85 ˚C
16ms min. @115VAC
LED Indicator #1 (Green)
ON : Unit Energized
14ms min. @115VAC (5V,6V Model)
OFF : Unit De-Energized
MTBF
61,000 Calculated Hours Minimum.
LED Indicator #2 (Amber)
ON : Battery Discharged
Approvals and Safety
UL60950-1, IEC/EN60950-1,
OFF : Battery Charged
Standards
K60950/K60335-1,2
EMC : EN55022/55024/61000
Case and Dimension
LP7 - Desktop
129(L) x 77(W) x 40(H) [mm]
5.8(L) x 3.05(W) x 1.59(H) [in]
Input Configuration
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
2 Conductor, 18AWG
Other cable and connectors are available.
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
BVW
06
120
01
03
K
Family Related
Design
Battery Charge
Voltage
Charge Constant
Current
Miscellaneous
Standard Output Cord Option
Design No.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B13
Standard Design Battery Charger
BHW Series Medical Sealed Lead Acid Fast Chargers
• Universal Input 100 to 250VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Battery Life
• Charges Lead Acid Battery
• LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Battery Voltage
Fast Charge Current
Switchover Current
Fast Charge
Float Charge
[V]
[A]
[A]
Voltage [V]
Voltage [V]
[W]
BHW-06-355-XXXXX
6
3.55
0.205
7.35
6.90
26.00
BHW-12-200-XXXXX
12
2.00
0.165
14.70
13.80
29.00
BHW-24-110-XXXXX
24
1.10
0.120
29.40
27.60
32.00
Model
Input Specification
Maximum Watts
Environmental Specification
Input Voltage Range
100 to 250VAC -10%, +6%
Operating Temperature
Line Frequency
47 to 63 Hz
Relative Humidity
5% to 95% non-condensing
Input Current
0.8A - 0.35A (Lower current with higher voltage)
Altitude
0 - 10,000 feet
Protection
Internal Primary Current Fuse, Inrush Limiting
Cooling
Convectional - Non vented case
Battery Type
Lead Acid 6V/12V/24V
Topology
Switching - Battery Charger
Charging Method
Constant Current and Constant Voltage
Leakage Current
Less than 100uA
Threshold Voltage
>1.75V / Cell
Dielectric Withstand
Cycle Charge Voltage
7.35V / 14.7V / 29.4V
Output Specification
0˚C to 40˚C with no derating
General Specification
Float Charge Voltage
6.9V / 13.8V / 27.6V
Protection
Over-current Protection (Hiccup)
Storage Temperature
Short Circuit Protection
Efficiency
LED Indicator #1 (Green)
ON : Unit Energized
LED Indicator #2 (Amber)
ON : Battery Discharged
5,656VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
500VDC Secondary - F.G
-30 ˚C to 85 ˚C
Minimum Average Efficyency in Active Mode
≥ [0.09 * Ln (Nameplate Output)] + 0.5
OFF : Unit De-Energized
Hold-up Time
10ms min. @115VAC
14ms min. @115VAC (5V,6V Model)
OFF : Battery Charged
Max. Power in No-Load
≤ 0.5W
MTBF
61,000 Calculated Hours Minimum.
Approvals and Safety
UL60601-1, IEC/EN60601-1,
Standards
K60950/K60335-1,2
EMC : EN60601-1-1-1-2/EN55024
Input Configuration
Case and Dimension
LP7 - Desktop
129(L) x 77(W) x 40(H) [mm]
5.8(L) x 3.05(W) x 1.59(H) [in]
Case Material
IEC320
C14 (F)
Black 94V0 Polycarbonate
Cord and Connectors
2 Conductor, 18AWG
Specify the input configuration Code in your Order.
Other cable and connectors are available.
Part Number Key
BVW
06
355
01
03
K
Family Related
Design
Battery Charge
Voltage
Charge Constant
Current
Miscellaneous
Standard Output Cord Option
Design No.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B14
Standard Design Battery Charger
JBL745-2 Series Sealed Lead Acid Fast Chargers
• Universal Input 100 to 240VAC
• Polycarbonate Enclosure Desktop Style
• Optimizes Battery Life
• Charges Lead Acid Battery
• LED Indicators
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Modified and Custom Designs Also Available
Battery Voltage
Fast Charge Current
Switchover Current
Fast Charge
Float Charge
[V]
[A]
[A]
Voltage [V]
Voltage [V]
[W]
JBL745-2-06-500-XXXXXX
6
5.00
0.500
7.35
6.90
26.00
JBL745-2-12-330-XXXXXX
12
2.50
0.250
14.70
13.80
29.00
JBL745-2-24-250-XXXXXX
24
1.50
0.150
29.40
27.60
32.00
Model
Input Specification
Maximum Watts
Environmental Specification
Input Voltage Range
100 to 240VAC +/-10%
Operating Temperature
Line Frequency
47 to 63 Hz
Relative Humidity
5% to 95% non-condensing
Input Current
1.0Amax at 110VAC Input
Altitude
0 - 10,000 feet
Protection
Internal Primary Current Fuse, Inrush Limiting
Cooling
Convectional - Non vented case
Battery Type
Lead Acid 6V/12V/24V
Topology
Switching - Battery Charger
Charging Method
Constant Current and Constant Voltage
Leakage Current
Less than 250uA
Threshold Voltage
>1.75V / Cell
Dielectric Withstand
Cycle Charge Voltage
2.45V +/-0.2V / Cell (as measure at PCB output)
Output Specification
0˚C to 40˚C with no derating
General Specification
Float Charge Voltage
2.30V +/-0.2V / Cell (as measure at PCB output)
Protection
Over-current Protection (Hiccup)
Storage Temperature
Short Circuit Protection
Hold-up Time
16ms min. @115VAC
RED : Charging
MTBF
61,000 Calculated Hours Minimum.
GREEN : Fully Charge
Approvals and Safety
UL60950-1, IEC/EN60950-1,
Flickering RED : Error
Standards
K60950/K60335-1,2
LED Indicator
Battery charger
4,250VDC Primary - Secondary
1,500VAC or 2,150VDC Primary - F.G
500VDC Secondary - F.G
-30 ˚C to 85 ˚C
EMC : EN55022/55024/61000
Case and Dimension
JEC#21 - Desktop
150(L) x 65(W) x 35(H) [mm]
5.9(L) x 2.56(W) x 1.38(H) [in]
Input Configuration
Case Material
Black 94V0 Polycarbonate
Cord and Connectors
2 Conductor, 18AWG
Other cable and connectors are available.
IEC320
C14 (F)
Specify the input configuration Code in your Order.
Part Number Key
JBL
745
Type
2
16
Family Related
Battery
Design
Type
Charge Constant
Voltage
BridgePower Corporation
250
51
02
Charge Constant Custom
Standard Output
Current
Cord Options
(marking,cord,etc.)
Tel : +82-31-299-1234
F
K
Standard Input
Cord Options
Design No.
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
B15
LED Power
LED Power
LED Power Supplies
LED Power Supplies
LED / Switching Mode Power Supply
LED / Switching Mode Power Supply
BridgePower Corporation
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L
L
LED / Switching Mode Power Supply
BPR010S Universal 10 Watt Series
• 100-240 Vac Universal Input
• Single Output to 10W
• Regulated Output with Low Ripple
• Meets Korea Safety Agency Requirements
• EK Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
40
0.25
10.0
400
BPR-010-S-40-X-XX
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.3A max. at 90VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min / 220V @ Full Load
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Storage Temperature
Output Specification
Line & Load Regulation
-30 ˚C to 85 ˚C
Efficiency
84% min
Hold-up Time
no Hold up time
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
EMI
Complies with EMC Directives
Ripple & Noise
1% Vp-p max.
MTBF
100,000Calculated Hours Minimum.
Over-current Protection (Hiccup)
Approvals and
K61347-2-13, K61347-1,K 62384, K00015
Short Circuit Protection
Safety Standards
EMC Compliant
Protection
Case and Dimension
8.2(L) x 1.7(W) x1.2(H) [in]
Environmental Specification
208(L) x 43(W) x 30(H) [mm]
-20˚C to 40˚C with no derating
Case Material
Metal
Relative Humidity
5% to 95% non-condensing
Cord and Connectors
2 Conductor, 18AWG
Altitude
0 - 10,000 feet
Cooling
Convectional
LED Driver
Operating Temperature
Other cable and connectors are available.
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR010
Product Family Name
S
40
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L1
LED / Switching Mode Power Supply
LED / Switching Mode Power Supply
BPR018S Universal
Universal 18
18 Watt
Watt Series
Series
BPR018S
• 100-240 Vac Universal Input
• 100-240 Vac Universal Input
• Single Output to 18W
• Single Output to 18W
• Regulated Output with Low Ripple
• Regulated Output with Low Ripple
• Meets Korea Safety Agency Requirements
• Meets Korea Safety Agency Requirements
• EK Compliant
• EK Compliant
• Metal Enclosure
• Metal Enclosure
• Modified and Custom Designs Also Available
• Modified and Custom Designs Also Available
• Wire Connection Style
• Wire Connection Style
Output Voltage
Output Voltage
DC (V)
DC (V)
Model
Model
BPR-018-S-40-X-XX
BPR-018-S-40-X-XX
Input Specification
Input Specification
Input Voltage Range
Input Voltage Range
Line Frequency
Line Frequency
Input Current
Input Current
Protection
Protection
Power Factor Correction
Power Factor Correction
Output Specification
Output Specification
Line & Load Regulation
Line & Load Regulation
(at End of Cable)
(at End of Cable)
Ripple & Noise
Ripple & Noise
Protection
Protection
Environmental Specification
Environmental Specification
Operating Temperature
Operating Temperature
Relative Humidity
Relative Humidity
Altitude
Altitude
Cooling
Cooling
Maximum
Maximum
Current (A)
Current (A)
40
40
100 to 240VAC -10%, +10%
100 to 240VAC -10%, +10%
47 to 63 Hz
47 to 63 Hz
0.3A max. at 90VAC Input
0.3A max. at 90VAC Input
Internal Primary Current Fuse, Inrush Limiting
Internal Primary Current Fuse, Inrush Limiting
0.9 min / 220V @ Full Load
0.9 min / 220V @ Full Load
Line Regulation
+/- 1%
Line Regulation
+/- 1%
Load Regulation
+/- 5%
Load Regulation
+/- 5%
1% Vp-p max.
1% Vp-p max.
Over-current Protection (Hiccup)
Over-current Protection (Hiccup)
Short Circuit Protection
Short Circuit Protection
-20˚C to 40˚C with no derating
-20˚C to 40˚C with no derating
5% to 95% non-condensing
5% to 95% non-condensing
0 - 10,000 feet
0 - 10,000 feet
Convectional
Convectional
0.40
0.40
General Specification
General Specification
Topology
Topology
Leakage Current
Leakage Current
Dielectric Withstand
Dielectric Withstand
Storage Temperature
Storage Temperature
Efficiency
Efficiency
Hold-up Time
Hold-up Time
EMI
EMI
MTBF
MTBF
Approvals and
Approvals and
Safety Standards
Safety Standards
Case and Dimension
Case and Dimension
Case Material
Case Material
Cord and Connectors
Cord and Connectors
Maximum
Maximum
Watts (W)
Watts (W)
16.0
16.0
Ripple & Noise
Ripple & Noise
Vp-p max. (mV)
Vp-p max. (mV)
400
400
Switching - Fixed Frequency Flyback
Switching - Fixed Frequency Flyback
Less than 250uA
Less than 250uA
4242VDC Primary - Secondary
4242VDC Primary - Secondary
2,150VDC Primary - F.G
2,150VDC Primary - F.G
500VDC Secondary - F.G
500VDC Secondary - F.G
-30 ˚C to 85 ˚C
-30 ˚C to 85 ˚C
84% min
84% min
no Hold up time
no Hold up time
Complies with EMC Directives
Complies with EMC Directives
100,000Calculated Hours Minimum.
100,000Calculated Hours Minimum.
K61347-2-13, K61347-1,K 62384, K00015
K61347-2-13, K61347-1,K 62384, K00015
EMC Compliant
EMC Compliant
8.2(L) x 1.7(W) x1.2(H) [in]
8.2(L) x 1.7(W) x1.2(H) [in]
208(L) x 43(W) x 30(H) [mm]
208(L) x 43(W) x 30(H) [mm]
Metal
Metal
2 Conductor, 18AWG
2 Conductor, 18AWG
Other cable and connectors are available.
Other cable and connectors are available.
Input Configuration
Input Configuration
Wire (E)
Wire (E)
Specify the input configuration Code in your Order.
Specify the input configuration Code in your Order.
Part Number Key
Part Number Key
BPR018
BPR018
Product Family Name
Product Family Name
S
S
Single Output
Single Output
BridgePower Corporation
BridgePower Corporation
40
40
Volt (DC)
Volt (DC)
X
X
Input Configuration
Input Configuration
XX
XX
Customer Number
Customer Number
Tel : +82-31-299-1234 Fax : +82-31-224-0566
Tel : +82-31-299-1234 Fax : +82-31-224-0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
L2
L2
LED / Switching Mode Power Supply
BPR020S Universal 20 Watt Series
• 100-240 Vac Universal Input
• Single Output to 20W
• Regulated Output with Low Ripple
• Meets Korea Safety Agency Requirements
• EK Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
40
0.50
20.0
400
BPR-020-S-40-X-XX
Input Specification
General Specification
Input Voltage Range
100 to 240VAC -10%, +10%
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.3A max. at 90VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min / 220V @ Full Load
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Storage Temperature
Output Specification
Line & Load Regulation
Line Regulation
+/- 1%
(at End of Cable)
Load Regulation
+/- 5%
Ripple & Noise
1% Vp-p max.
Protection
-30 ˚C to 85 ˚C
Efficiency
84% min
Hold-up Time
no Hold up time
EMI
Complies with EMC Directives
MTBF
100,000Calculated Hours Minimum.
Over-current Protection (Hiccup)
Approvals and
K61347-2-13, K61347-1,K 62384, K00015
Short Circuit Protection
Safety Standards
EMC Compliant
Case and Dimension
8.2(L) x 1.7(W) x1.2(H) [in]
208(L) x 43(W) x 30(H) [mm]
Environmental Specification
Case Material
-20˚C to 50˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional
Metal
Cord and Connectors
2 Conductor, 18AWG
Other cable and connectors are available.
LED Driver
Operating Temperature
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR020
Product Family Name
S
40
X
XX
Single Output
Volt (DC)
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L3
LED / Switching Mode Power Supply
BPR025S Universal 23 Watt Series
• 100-240 Vac Universal Input
• Single Output to 23W
• Regulated Output with Low Ripple
• Meets Korea Safety Agency Requirements
• EMC Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
32 - 42
0.57
22.8
400
BPR-025-S-40-X-XX
Input Specification
General Specification
Input Voltage Range
90 to 264VAC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.25A max. at 120VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min / 220V @ Full Load
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Efficiency
85% min
Line & Load Regulation
Line Regulation
+/- 1%
Hold-up Time
Half cycle min. @120VAC
(at End of Cable)
Load Regulation
+/- 5%
EMI
Complies with EMC Directives
Ripple & Noise
1% Vp-p max.
MTBF
100,000Calculated Hours Minimum.
Protection
Over-current Protection (Hiccup)
Approvals and
EN61347-1 EN55015,EN55022 Class B
Short Circuit Protection
Safety Standards
EN61000-3-2 Class C, EN61547, EN55024,
ES C CISPR15, KS C 61547
Case and Dimension
7.48(L) x 1.37(W) x1.18(H) [in]
Environmental Specification
190(L) x 35(W) x 30(H) [mm]
Operating Temperature
-20˚C to 50˚C with no derating
Case Material
Metal
Relative Humidity
5% to 95% non-condensing
Cord and Connectors
Input and Output wire use lead wires
Altitude
0 - 10,000 feet
Cooling
Convectional
lead wires are 18AWG 105C/600V
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR025
Product Family Name
S
72
X
XX
Single Output
Custom Option
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L4
LED / Switching Mode Power Supply
BPR025S Universal 25 Watt Series
• 120-277 Vac Universal Input
• Single Output to 25W
• Regulated Output with Low Ripple
• Meets UL8750 Safety Agency Requirements
• EMC Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
66
0.35
23.1
660
BPR-025-S-72-X-XX
Input Specification
General Specification
Input Voltage Range
120 to 277VAC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.6A max. at 120VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min, Built-in active PFC
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Efficiency
87% min
Line & Load Regulation
Line Regulation
+/- 1%
Hold-up Time
Half cycle min. @120VAC
(at End of Cable)
Load Regulation
+/- 5%
EMI
Complies with EMC Directives
Ripple & Noise
1% Vp-p max.
MTBF
100,000Calculated Hours Minimum.
Protection
Over-current Protection (Hiccup)
Approvals and
UL8750, UL1012 non Class-2
Short Circuit Protection
Safety Standards
EMC Compliant
Case and Dimension
6(L) x 3(W) x1.25(H) [in]
Environmental Specification
152.4(L) x 76.2(W) x 31.75(H) [mm]
-20˚C to 50˚C with no derating
Case Material
Metal
Relative Humidity
5% to 95% non-condensing
Cord and Connectors
Input and Output wire use lead wires
Altitude
0 - 10,000 feet
Cooling
Convectional
LED Driver
Operating Temperature
lead wires are 18AWG 105C/600V
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR025
Product Family Name
S
72
X
XX
Single Output
Custom Option
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L5
LED / Switching Mode Power Supply
BPR028S Universal 23 Watt Series
• 120-277 Vac Universal Input
• Single Output to 23W
• Regulated Output with Low Ripple
• Meets UL8750 Safety Agency Requirements
• EMC Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
16 - 32
0.70
22.4
320
BPR-028-S-44-X-XX
Input Specification
General Specification
Input Voltage Range
120 to 277VAC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.6A max. at 120VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Efficiency
87% min
Line & Load Regulation
Line Regulation
+/- 1%
Hold-up Time
Half cycle min. @120VAC
(at End of Cable)
Load Regulation
+/- 5%
EMI
Complies with EMC Directives
Ripple & Noise
1% Vp-p max.
MTBF
100,000Calculated Hours Minimum.
Protection
Over-current Protection (Hiccup)
Approvals and
UL8750, UL1310 Class-2
Short Circuit Protection
Safety Standards
EMC Compliant
Case and Dimension
5.3(L) x 1.3(W) x1.0(H) [in]
135(L) x 34(W) x 25.4(H) [mm]
Environmental Specification
Case Material
Operating Temperature
-20˚C to 50˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional
Metal
Cord and Connectors
Input and Output wire use lead wires
lead wires are 18AWG 105C/600V
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR028
Product Family Name
S
44
X
XX
Single Output
Custom Option
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L6
LED / Switching Mode Power Supply
BPR050S Universal 50 Watt
• 120-277 Vac Universal Input
• Single Output to 50W
• Regulated Output with Low Ripple
• Meets UL8750 Safety Agency Requirements
• EMC Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
66
0.78
51.5
660
BPR-050-S-72-X-XX
Input Specification
General Specification
Input Voltage Range
120 to 277VAC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.7A max. at 120VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min, Built-in active PFC
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Efficiency
87% min
Line & Load Regulation
Line Regulation
+/- 1%
Hold-up Time
Half cycle min. @120VAC
(at End of Cable)
Load Regulation
+/- 5%
EMI
Complies with EMC Directives
Ripple & Noise
1% Vp-p max.
MTBF
100,000Calculated Hours Minimum.
Protection
Over-current Protection (Hiccup)
Approvals and
UL8750, UL1012 non Class-2
Short Circuit Protection
Safety Standards
EMC Compliant
Case and Dimension
6(L) x 3(W) x1.25(H) [in]
152.4(L) x 76.2(W) x 31.75(H) [mm]
Environmental Specification
Case Material
-20˚C to 50˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional
Metal
Cord and Connectors
Input and Output wire use lead wires
lead wires are 18AWG 105C/600V
LED Driver
Operating Temperature
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR050
Product Family Name
S
72
X
XX
Single Output
Custom Option
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L7
LED / Switching Mode Power Supply
BPR063S Universal 63 Watt
• 120-277 Vac Universal Input
• Single Output to 63W
• Regulated Output with Low Ripple
• Meets UL8750 Safety Agency Requirements
• EMC Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
Model
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
88
0.78
68.6
880
BPR-063-S-96-X-XX
Input Specification
General Specification
Input Voltage Range
120 to 277VAC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.8A max. at 120VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min, Built-in active PFC
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Efficiency
87% min
Line & Load Regulation
Line Regulation
+/- 1%
Hold-up Time
Half cycle min. @120VAC
(at End of Cable)
Load Regulation
+/- 5%
EMI
Complies with EMC Directives
Ripple & Noise
1% Vp-p max.
MTBF
100,000Calculated Hours Minimum.
Protection
Over-current Protection (Hiccup)
Approvals and
UL8750, UL1012 Non Class2
Short Circuit Protection
Safety Standards
EMC Compliant
Case and Dimension
6(L) x 3(W) x1.25(H) [in]
152.4(L) x 76.2(W) x 31.75(H) [mm]
Environmental Specification
Case Material
Operating Temperature
-20˚C to 50˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional
Metal
Cord and Connectors
Input and Output wire use lead wires
lead wires are 18AWG 105C/600V
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR063
Product Family Name
S
96
X
XX
Single Output
Custom Option
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L8
LED / Switching Mode Power Supply
BPR062S Universal 62 Watt
• 120-277 Vac Universal Input
• Single Output to 62W
• Regulated Output with Low Ripple
• Meets UL8750 Safety Agency Requirements
• EMC Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
• 0 – 100% Range PWM dimming, 0 – 10V Interface or
with low voltage signal input of control module.
Model
Output Voltage Range
Maximum
Maximum
Current
DC (V)
Current (A)
Watts (W)
Accracy (%)
(*) BPR-062-S-88-X-XX
62
-
88
0.70
61.6
+/- 3%
(**) BPR-062-S-44-X-XX
30
-
44
1.40
61.6
+/- 3%
Input Specification
General Specification
Input Voltage Range
120 to 277VAC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.7A max. at 120VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min, Built-in active PFC
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Efficiency
87% min
Line & Load Regulation
Line Regulation
+/- 1%
Hold-up Time
Half cycle min. @120VAC
(at End of Cable)
Load Regulation
+/- 5%
EMI
Complies with EMC Directives
Ripple & Noise
1% Vp-p max.
MTBF
100,000Calculated Hours Minimum.
Protection
Over-current Protection (Hiccup)
Approvals and
UL8750, UL1012 Non Class-2, UL1310 Class-2
Short Circuit Protection
Safety Standards
EMC Compliant
(*)
Case and Dimension
6(L) x 3(W) x1.25(H) [in]
152.4(L) x 76.2(W) x 31.75(H) [mm]
Environmental Specification
(**) 12.87(L) x 1.6(W) x1.125(H) [in]
327(L) x 40.64(W) x 28.57(H) [mm]
Operating Temperature
-40˚C to 50˚C with no derating
Relative Humidity
5% to 95% non-condensing
Case Material
Altitude
0 - 10,000 feet
Cord and Connectors
Cooling
Convectional
LED Driver
Metal
3 Conductor, 18AWG
Other cable and connectors are available.
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR062
Product Family Name
S
88
X
XX
Single Output
Custom Option
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L9
LED / Switching Mode Power Supply
BPR092S Universal 92 Watt
• 120-277 Vac Universal Input
• Single Output to 92W
• Regulated Output with Low Ripple
• Meets UL8750 Safety Agency Requirements
• EMC Compliant
• Metal Enclosure
• Modified and Custom Designs Also Available
• Wire Connection Style
• 0 – 100% Range dimming, 0 – 10V Interface or
with low voltage signal input of control module.
Model
Output Voltage Range
Maximum
Maximum
Current
DC (V)
Current (A)
Watts (W)
Accracy (%)
1.05
92.4
+/- 3%
BPR-092-S-88-X-XX
62
-
88
Input Specification
General Specification
Input Voltage Range
120 to 277VAC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
0.9A max. at 120VAC Input
Dielectric Withstand
Protection
Internal Primary Current Fuse, Inrush Limiting
Power Factor Correction
0.9 min, Built-in active PFC
4242VDC Primary - Secondary
2,150VDC Primary - F.G
500VDC Secondary - F.G
Output Specification
Storage Temperature
-30 ˚C to 85 ˚C
Efficiency
87% min
Line & Load Regulation
Line Regulation
+/- 1%
Hold-up Time
Half cycle min. @120VAC
(at End of Cable)
Load Regulation
+/- 5%
EMI
Complies with EMC Directives
Ripple & Noise
1% Vp-p max.
MTBF
100,000Calculated Hours Minimum.
Protection
Over-current Protection (Hiccup)
Approvals and
UL8750, UL1012 Non Class2
Short Circuit Protection
Safety Standards
EMC Compliant
Case and Dimension
6(L) x 3(W) x1.25(H) [in]
152.4(L) x 76.2(W) x 31.75(H) [mm]
Environmental Specification
Case Material
Operating Temperature
-40˚C to 50˚C with no derating
Relative Humidity
5% to 95% non-condensing
Altitude
0 - 10,000 feet
Cooling
Convectional
Metal
Cord and Connectors
3 Conductor, 18AWG
Other cable and connectors are available.
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Part Number Key
BPR092
Product Family Name
S
88
X
XX
Single Output
Custom Option
Input Configuration
Customer Number
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
L10
BPR123S Universal 123 Watt
LED / Switching Mode Power Supply
BPR123S Universal 123 Watt
BPR123S Universal 123 Watt
LED / Switching Mode Power Supply
LED / Switching Mode Power Supply
• 120-277 Vac Universal Input
• Single Output to 123W
• Regulated Output with Low Ripple
• 120-277 Vac Universal Input
• Meets UL8750 Safety Agency Requirements
120-277
Vac to
Universal
• Single
Output
123W Input
• EMC Compliant
Single Output
to 123W
• Regulated
Output
with Low Ripple
• Metal Enclosure
Regulated
Output
withAgency
Low Ripple
• Meets
UL8750
Safety
Requirements
• Modified and Custom Designs Also Available
MeetsCompliant
UL8750 Safety Agency Requirements
• EMC
• Wire Connection Style
EMC Compliant
• Metal
Enclosure
• 0 – 100% Range dimming, 0 – 10V Interface or
Metal Enclosure
• Modified
and Custom Designs Also Available
with low voltage signal input of control module.
Modified
and Custom
• Wire
Connection
StyleDesigns Also Available
Connection
Style
• 0Wire
– 100%
Range dimming,
0 – 10V Interface or
• with
0 – 100%
Range dimming,
0 –of10V
Interface
or
low voltage
signal input
control
module.
with low voltage signal
input of control module.
Model
BPR-123-S-88-X-XX
Model
Output Voltage Range
Maximum
Maximum
Current
DC (V)
Current (A)
Watts (W)
Accracy (%)
62
Model
BPR-123-S-88-X-XX
-
1.40
88
123.2
+/- 3%
Output Voltage Range
Maximum
Maximum
Current
Output Voltage
DC (V) Range
Maximum
Current
(A)
Maximum
Watts (W)
Current
Accracy
(%)
62 DC-(V) 88
62 88
Current
1.40 (A)
Watts
123.2(W)
Accracy
+/- 3%(%)
1.40
123.2
+/- 3%
BPR-123-S-88-X-XX
Input Specification
General Specification
Input Voltage Range
120 to 277VAC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 63 Hz
Leakage Current
Less than 250uA
Input Current
InputVoltage
Specification
Input
Range
Protection
InputFrequency
Voltage Range
Line
Power Factor Correction
Line Frequency
Input
Current
1.3A max. at 120VAC Input
120 to 277VAC
Internal Primary Current Fuse, Inrush Limiting
120toto63277VAC
47
Hz
0.9 min, Built-in active PFC
47 tomax.
63 Hzat 120VAC Input
1.3A
Dielectric Withstand
General Specification
Topology
4242VDC Primary - Secondary
Switching - Fixed Frequency Flyback
2,150VDC Primary - F.G
Switching
- Fixed Frequency Flyback
Less
than 250uA
500VDC Secondary - F.G
Less than Primary
250uA - Secondary
4242VDC
-30 ˚C to 85 ˚C
4242VDC Primary
2,150VDC
Primary--Secondary
F.G
87% min
2,150VDC
Primary --F.G
500VDC
Secondary
F.G
Half cycle min. @120VAC
500VDC
- F.G
-30
˚C toSecondary
85 ˚C
Complies with EMC Directives
-30 ˚Cmin
to 85 ˚C
87%
100,000Calculated Hours Minimum.
87% cycle
min min. @120VAC
Half
UL8750, UL1012 Non Class2
Half cycle with
min. EMC
@120VAC
Complies
Directives
EMC Compliant
Complies with EMCHours
Directives
100,000Calculated
Minimum.
6(L) x 3(W) x1.57(H) [in]
100,000Calculated
Hours
Minimum.
UL8750,
UL1012 Non
Class2
152.4(L) x 76.2(W) x 40.0(H) [mm]
UL8750,
UL1012 Non Class2
EMC
Compliant
Metal
EMCxCompliant
6(L)
3(W) x1.57(H) [in]
3 Conductor, 18AWG
6(L) x 3(W)
x1.57(H)x [in]
152.4(L)
x 76.2(W)
40.0(H) [mm]
Other cable and connectors are available.
152.4(L) x 76.2(W) x 40.0(H) [mm]
Metal
Input Specification
Input Current
Protection
1.3A max.
at 120VAC
Input
Internal
Primary
Current
Fuse, Inrush Limiting
Protection
Power
Factor Correction
Line & Load Regulation
Power Factor Correction
(at End of Cable)
Internal
Current
0.9
min, Primary
Built-in active
PFCFuse, Inrush Limiting
Line Regulation
+/- 1%
0.9 min, Built-in active PFC
Load Regulation
+/- 5%
Ripple & Noise
Output
Specification
Line
& Load
Regulation
Protection
Line
& Load
Regulation
(at End
of Cable)
1% Vp-p max.
Line Regulation
+/- 1%
Over-current Protection (Hiccup)
Line Regulation
1%
Load
Regulation
+/- 5%
Short Circuit Protection
Load
Regulation
+/- 5%
1%
Vp-p
max.
Output Specification
Output Specification
(at End&ofNoise
Cable)
Ripple
Ripple & Noise
Protection
1% Vp-p max.Protection (Hiccup)
Over-current
Protection
Over-current
Protection (Hiccup)
Short
Circuit Protection
Operating Temperature
Short Circuit Protection
-40˚C to 50˚C with no derating
Environmental Specification
5% to 95% non-condensing
Cooling
Operating
Temperature
Relative
Humidity
0 - 10,000 feet
-40˚C to 50˚C with no derating
Convectional
-40˚C
50˚C
with no derating
5%
to to
95%
non-condensing
Relative Humidity
Altitude
to 95%feet
non-condensing
05%- 10,000
Altitude
Cooling
0 - 10,000 feet
Convectional
Cooling
Convectional
Input Configuration
TopologyCurrent
Leakage
Leakage Current
Dielectric
Withstand
Storage Temperature
Dielectric Withstand
Efficiency
Hold-up Time
Storage Temperature
EMI
Storage Temperature
Efficiency
MTBF
EfficiencyTime
Hold-up
Approvals and
Hold-up Time
EMI
Safety Standards
EMI
MTBF
Case and Dimension
MTBF
Approvals
and
Approvals
and
Safety
Standards
Case Material
Safetyand
Standards
Case
Dimension
Cord and Connectors
Case and Dimension
Case Material
Case Material
Cord
and Connectors
Metal
3
Conductor, 18AWG
Cord and Connectors
3 Conductor,
18AWG
Other
cable and
connectors are available.
LED Driver
Relative Humidity
Environmental Specification
Altitude
Environmental
Specification
Operating
Temperature
General Specification
Other cable and connectors are available.
Input Configuration
Input Configuration
Wire (E)
Specify the input configuration Code in your Order.
Wire (E)
Wire (E)
Specify
the input configuration Code in your Order.
Part Number Key
BPR123
Specify the input configuration Code in your Order.
Part Number
ProductKey
Family Name
Part NumberBPR123
Key
BPR123
Product Family Name
Product Family Name
S
88
Single Output
S
S
Single Output
Single Output
Custom Option
88
88
Custom Option
Custom Option
BridgePower Corporation
BridgePower Corporation
BridgePower Corporation
X
XX
Input Configuration
Customer Number
X
XX
X
XX
Input Configuration
Customer Number
Input
Number
Tel : Configuration
+82-31-299-1234 Customer
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
Tel : +82-31-299-1234 Fax : +82-31-224-0566
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
L11
L11
L11
Internal
INTERNAL Power Supplies
INTERNAL (Communication & Industry)
POWER SUPPLY
Unit Type Single & Multi Output
PC Board Type Single Output
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
N
Internal
INTERNAL Power Supplies
INTERNAL (Communication & Industry)
POWER SUPPLY
Unit Type Single & Multi Output
PC Board Type Single Output
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
N
AE Series Single Output Power Supply
AE15S Universal 15 Watt Series
• Universal Input 100 to 250VAC
• Printed Board Type
• Single Output to 15W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• One or Two Year Warranty
• Modified and Custom Designs Also Available
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
AE15S05
5
3.00
15.0
50
AE15S09
9
1.70
15.3
90
AE15S12
12
1.30
15.6
120
AE15S15
15
1.00
15.0
150
AE15S24
24
0.60
14.4
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 250VAC or 120 to 330VDC
Topology
Switching - Fixed Frequency
Line Frequency
47 to 440Hz or DC
Leakage Current
Less than 250uA
Input Current
0.37A max. at 110VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse
Isolated
50Mohm Primary-Secondary ;
Inrush Limiting
20A / 40A Type. (110 / 220VAC)
2,000VAC @1min(20mA), DC500V
Full Load, at Cold start
50Mohm Primary-Case.FG :
Output Specification
500VAC @1min(100mA), DC500V
Line & Load Regulatrion
Line Regulation
+/- 1%
50Mohm Secondary-Case.FG
(at End of Cable)
Load Regulation
+/- 2%
(at room temperature of humidity)
Transient Response
0.5ms for 50% Load change Typ.
Spacing
Min. 8mm Primary-Secondary
Protection
Foldback over-current Protection
Efficiency
+5V : 70%, +9V : 72%, +12V, +15V : 75%,
Short Circuit Protection
+24V : 78%
Environmental Specification
Start-On Time
1sec max. @100VAC
Hold-up Time
10ms Typ. @100VAC
Operating Temperature
-10˚C to 50˚C with no derating
EMI
Built to meet FCC Class A
Relative Humidity
20% to 95% non-condensing
MTBF
100,000 Calculated Hours Minimum.
Storage Temperature
-20 ˚C to 75 ˚C
Dimension
Altitude
0 - 10,000 feet
4.53(L) x 1.97(W) x 1.14(H) [in]
115(L) x 50(W) x 29(H) [mm]
Cooling
Convectional - Non vented case
Vibration
10 to 55Hz, at 1G 3min periods,
Connectors
Primary YW396-05 / YH396-05V
Secondary YW396-04 / YH396-04
30min along X,Y and Z axis, at no operating
Impact (in package)
Less than 10G
Part Number Key
AE
Series Name
S
05
Output Channel
Output Voltage
Internal
30
Total Output
Wattage
* Output Channel : S = Single Output, D = Double Output, T = Triple Output
* Output Voltage : Single : 05 = +5V, 12 = +12V, 15 = +15V, 24 = +24V
Double : 12 = +12V/+12V, 15 = +15V/+15V,
512 = +5V/+12V, 524 = +5V/+24V
Triple : 512 = +5V/+12V/-12V, 515 = +5V/+15V/-15V
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
N1
AE Series Single Output Power Supply
AE30S Universal 30 Watt Series
• Universal Input 100 to 250VAC
• Printed Board Type
• Single Output to 30W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• One or Two Year Warranty
• Modified and Custom Designs Also Available
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
AE30S05
5
6.00
30.0
50
AE30S09
9
3.33
30.0
90
AE30S12
12
2.50
30.0
120
AE30S15
15
2.00
30.0
150
AE30S24
24
1.30
31.2
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 250VAC or 120 to 330VDC
Topology
Switching - Fixed Frequency
Line Frequency
47 to 440Hz or DC
Leakage Current
Less than 250uA
Input Current
0.37A max. at 110VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse
Isolated
50Mohm Primary-Secondary ;
Inrush Limiting
20A / 40A Type. (110 / 220VAC)
2,000VAC @1min(20mA), DC500V
Full Load, at Cold start
50Mohm Primary-Case.FG;
Output Specification
500VAC @1min(100mA), DC500V
Line & Load Regulatrion
Line Regulation
+/- 1%
50Mohm Secondary-Case.FG
(at End of Cable)
Load Regulation
+/- 2%
(at room temperature of humidity)
Transient Response
0.5ms for 50% Load change Typ.
Spacing
Min. 8mm Primary-Secondary
Protection
Foldback over-current Protection
Efficiency
+5V : 70%, +9V : 72%, +12V, +15V : 75%,
Start-On Time
1sec max. @100VAC
Hold-up Time
10ms Typ. @100VAC
Short Circuit Protection
+24V : 78%
Over Voltage Protection
Environmental Specification
Operating Temperature
-10˚C to 50˚C with no derating
EMI
Built to meet FCC Class A
Relative Humidity
20% to 95% non-condensing
MTBF
100,000 Calculated Hours Minimum.
Storage Temperature
-20 ˚C to 75 ˚C
Dimension
Altitude
0 - 10,000 feet
5.2(L) x 2.13(W) x 1.14(H) [in]
132(L) x 54(W) x 29(H) [mm]
Cooling
Convectional - Non vented case
Vibration
10 to 55Hz, at 1G 3min periods,
Connectors
Primary YW396-05 / YH396-05V
Secondary YW396-04 / YH396-04
30min along X,Y and Z axis, at no operating
Impact (in package)
Less than 10G
Part Number Key
AE
Series Name
15
S
05
Total Output
Wattage
Output Channel
Output Voltage
* Output Channel : S = Single Output, D = Double Output, T = Triple Output
* Output Voltage : Single : 05 = +5V, 12 = +12V, 15 = +15V, 24 = +24V
Double : 12 = +12V/+12V, 15 = +15V/+15V,
512 = +5V/+12V, 524 = +5V/+24V
Triple : 512 = +5V/+12V/-12V, 515 = +5V/+15V/-15V
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
N2
AE Series Single Output Power Supply
AE Series Single Output Power Supply
AE50S
AE50S Universal
Universal 50
50 Watt
Watt Series
Series
• Universal Input 100 to 250VAC
• Universal Input 100 to 250VAC
• Printed Board Type
• Printed Board Type
• Single Output to 50W
• Single Output to 50W
• Regulated Output with Low Ripple
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• Private Label Marking Available
• One or Two Year Warranty
• One or Two Year Warranty
• Modified and Custom Designs Also Available
• Modified and Custom Designs Also Available
Output Voltage
Output Voltage
DC (V)
DC (V)
5
5
9
9
12
12
15
15
24
24
Model
Model
AE50S05
AE50S05
AE50S09
AE50S09
AE50S12
AE50S12
AE50S15
AE50S15
AE50S24
AE50S24
Input Specification
Input Specification
Input Voltage Range
Input Voltage Range
Line Frequency
Line Frequency
Input Current
Input Current
Protection
Protection
Inrush Limiting
Inrush Limiting
100 to 250VAC or 120 to 330VDC
100 to 250VAC or 120 to 330VDC
47 to 440Hz or DC
47 to 440Hz or DC
1.2A max. at 110VAC Input
1.2A max. at 110VAC Input
Internal Primary Current Fuse
Internal Primary Current Fuse
20A / 40A Type. (110 / 220VAC)
20A / 40A Type. (110 / 220VAC)
Full Load, at Cold start
Full Load, at Cold start
Output Specification
Output Specification
Line & Load Regulatrion
Line & Load Regulatrion
(at End of Cable)
(at End of Cable)
Transient Response
Transient Response
Protection
Protection
Environmental Specification
Environmental Specification
Operating Temperature
Operating Temperature
Relative Humidity
Relative Humidity
Storage Temperature
Storage Temperature
Altitude
Altitude
Cooling
Cooling
Vibration
Vibration
Impact (in package)
Impact (in package)
* Output Channel
* Output Channel
* Output Voltage
* Output Voltage
Line Regulation
+/- 1%
Line Regulation
+/- 1%
Load Regulation
+/- 2%
Load Regulation
+/- 2%
0.5ms for 50% Load change Typ.
0.5ms for 50% Load change Typ.
Foldback over-current Protection
Foldback over-current Protection
Short Circuit Protection
Short Circuit Protection
Over Voltage Protection
Over Voltage Protection
-10˚C to 50˚C with no derating
-10˚C to 50˚C with no derating
20% to 95% non-condensing
20% to 95% non-condensing
-20 ˚C to 75 ˚C
-20 ˚C to 75 ˚C
0 - 10,000 feet
0 - 10,000 feet
Convectional - Non vented case
Convectional - Non vented case
10 to 55Hz, at 1G 3min periods,
10 to 55Hz, at 1G 3min periods,
30min along X,Y and Z axis, at no operating
30min along X,Y and Z axis, at no operating
Less than 10G
Less than 10G
50
50
Total Output
Total
Output
Wattage
Wattage
S
S
Output Channel
Output Channel
Maximum
Maximum
Watts (W)
Watts (W)
50.0
50.0
49.5
49.5
50.4
50.4
50.0
50.0
50.4
50.4
General Specification
General Specification
Topology
Topology
Leakage Current
Leakage Current
Dielectric Withstand
Dielectric Withstand
Isolated
Isolated
Spacing
Spacing
Efficiency
Efficiency
Start-On Time
Start-On Time
Hold-up Time
Hold-up Time
EMI
EMI
MTBF
MTBF
Dimension
Dimension
Connectors
Connectors
Ripple & Noise
Ripple & Noise
Vp-p max. (mV)
Vp-p max. (mV)
50
50
90
90
120
120
150
150
240
240
Switching - Fixed Frequency Flyback
Switching - Fixed Frequency Flyback
Less than 250uA
Less than 250uA
4,242VDC Primary - Secondary
4,242VDC Primary - Secondary
50Mohm Primary-Secondary ;
50Mohm Primary-Secondary ;
2,000VAC @1min(20mA), DC500V
2,000VAC @1min(20mA), DC500V
50Mohm Primary-Case.FG;
50Mohm Primary-Case.FG;
500VAC @1min(100mA), DC500V
500VAC @1min(100mA), DC500V
50Mohm Secondary-Case.FG
50Mohm Secondary-Case.FG
(at room temperature of humidity)
(at room temperature of humidity)
Min. 8mm Primary-Secondary
Min. 8mm Primary-Secondary
+5V, +9V : 73%, +9V : 75%, +12V : 75%,
+5V, +9V : 73%, +9V : 75%, +12V : 75%,
+15V, +24V : 77%
+15V, +24V : 77%
1sec max. @100VAC
1sec max. @100VAC
16ms Typ. @100VAC
16ms Typ. @100VAC
Built to meet FCC Class A
Built to meet FCC Class A
100,000 Calculated Hours Minimum.
100,000 Calculated Hours Minimum.
7.68(L) x 2.17(W) x 1.23(H) [in]
7.68(L) x 2.17(W) x 1.23(H) [in]
195(L) x 55(W) x 33(H) [mm]
195(L) x 55(W) x 33(H) [mm]
Primary YW396-05 / YH396-05V
Primary YW396-05 / YH396-05V
Secondary YW396-04 / YH396-04
Secondary YW396-04 / YH396-04
05
05
Output Voltage
Output Voltage
Internal
Part Number Key
Part Number
AE Key
AE
Series Name
Series Name
Maximum
Maximum
Current (A)
Current (A)
10.00
10.00
5.50
5.50
4.20
4.20
3.33
3.33
2.10
2.10
: S = Single Output, D = Double Output, T = Triple Output
: S = Single Output, D = Double Output, T = Triple Output
: Single : 05 = +5V, 12 = +12V, 15 = +15V, 24 = +24V
: Single : 05 = +5V, 12 = +12V, 15 = +15V, 24 = +24V
Double : 12 = +12V/+12V, 15 = +15V/+15V,
Double : 12 = +12V/+12V, 15 = +15V/+15V,
512 = +5V/+12V, 524 = +5V/+24V
512 = +5V/+12V, 524 = +5V/+24V
Triple : 512 = +5V/+12V/-12V, 515 = +5V/+15V/-15V
Triple : 512 = +5V/+12V/-12V, 515 = +5V/+15V/-15V
BridgePower Corporation
BridgePower Corporation
Tel : +82-31-299-1234 Fax : +82-31-224-0566
Tel : +82-31-299-1234 Fax : +82-31-224-0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
N3
N3
AE Series Single Output Power Supply
AE60S Universal 60 Watt Series
• Universal Input 100 to 250VAC
• Printed Board Type
• Single Output to 60W
• Regulated Output with Low Ripple
• Meets Safety Agency Requirements
• Complies with EMI/RFI Regulations
• Private Label Marking Available
• One or Two Year Warranty
• Modified and Custom Designs Also Available
Output Voltage
Maximum
Maximum
Ripple & Noise
DC (V)
Current (A)
Watts (W)
Vp-p max. (mV)
AE60S05
5
12.00
60.0
50
AE60S09
9
6.70
60.3
90
AE60S12
12
5.00
60.0
120
AE60S15
15
4.00
60.0
150
AE60S24
24
2.50
60.0
240
Model
Input Specification
General Specification
Input Voltage Range
100 to 250VAC or 120 to 330VDC
Topology
Switching - Fixed Frequency Flyback
Line Frequency
47 to 440Hz or DC
Leakage Current
Less than 250uA
Input Current
1.4A max. at 110VAC Input
Dielectric Withstand
4,242VDC Primary - Secondary
Protection
Internal Primary Current Fuse
Isolated
50Mohm Primary-Secondary ;
Inrush Limiting
20A / 40A Type. (110 / 220VAC)
2,000VAC @1min(20mA), DC500V
Full Load, at Cold start
50Mohm Primary-Case.FG;
Output Specification
500VAC @1min(100mA), DC500V
Line & Load Regulatrion
Line Regulation
+/- 1%
50Mohm Secondary-Case.FG
(at End of Cable)
Load Regulation
+/- 2%
(at room temperature of humidity)
Transient Response
0.5ms for 50% Load change Typ.
Spacing
Min. 8mm Primary-Secondary
Protection
Foldback over-current Protection
Efficiency
+5V : 70%, +9V : 72%, +12V, +15V : 75%,
Start-On Time
1sec max. @100VAC
Hold-up Time
16ms Typ. @100VAC
Short Circuit Protection
+24V : 78%
Over Voltage Protection
Environmental Specification
Operating Temperature
-10˚C to 50˚C with no derating
EMI
Built to meet FCC Class A
Relative Humidity
20% to 95% non-condensing
MTBF
100,000 Calculated Hours Minimum.
Storage Temperature
-20 ˚C to 75 ˚C
Dimension
Altitude
0 - 10,000 feet
7.68(L) x 2.17(W) x 1.23(H) [in]
195(L) x 55(W) x 33(H) [mm]
Cooling
Convectional - Non vented case
Vibration
10 to 55Hz, at 1G 3min periods,
Connectors
Primary YW396-05 / YH396-05V
Secondary YW396-04 / YH396-04
30min along X,Y and Z axis, at no operating
Impact (in package)
Less than 10G
Part Number Key
AE
Series Name
60
S
05
Total Output
Wattage
Output Channel
Output Voltage
* Output Channel : S = Single Output, D = Double Output, T = Triple Output
* Output Voltage : Single : 05 = +5V, 12 = +12V, 15 = +15V, 24 = +24V
Double : 12 = +12V/+12V, 15 = +15V/+15V,
512 = +5V/+12V, 524 = +5V/+24V
Triple : 512 = +5V/+12V/-12V, 515 = +5V/+15V/-15V
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
N4
Input Configuration
Input Configuration
Input Configuration
Input Configuration
Input Connectors
Input Connectors
Model
Model
Profile & Dimension
Profile & Dimension
B
B
C
C
D
D
E
E
F
F
G
G
Description
Description
2-Prong AC
2-Prong
AC
Input Plug
Input Plug
Japanese
Japanese
AC Input
AC Input
Plug
with
Plug
with
Ground
Ground
AC Input
AC Input
Plug
with
Plug
with
Ground
Ground
AC Input
AC
Input
Plug
Plug
Europe
Europe
with
Ground
with Ground
IEC Input
IEC Input
Receptacle
Receptacle
AC Input
AC
Input
Plug
Plug
U.K
with U.K
Ground
with Ground
Model
Model
Profile & Dimension
Profile & Dimension
H
H
Description
Description
2-Prong AC
2-Prong
AC
Input Plug
Input Plug
Japanese
Japanese
AC Input
AC Input
Plug
with
II
Plug
with
Ground
Ground
AC Input
AC Input
Plug
with
K
K
Plug
with
Ground
Ground
AC Input
AC
Input
Plug
L
L
Plug
Europe
Europe
with
Ground
with Ground
IEC Input
IEC Input
Receptacle
Receptacle
M
M
AC Input
AC
Input
Plug
N
N
Plug
U.K
with U.K
Ground
with Ground
Typical input and output cord length : 6 to 8 ft. Conductor gauges #18 to #22, depending on electrical
Typical
input and
output
cord application.
length : 6 to 8 ft. Conductor gauges #18 to #22, depending on electrical
characteristics
and
particular
characteristics
particular
application.
Also offered areand
several
versions
of input and output cord configurations with no connector.
Also
offered
are several
versions
input and
configurations with no connector.
All such
unterminated
cords
have of
stripped
are output
tinned cord
leads.
All such unterminated cords have stripped are tinned leads.
BridgePower Corporation
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
P1
P1
Output Configuration
Output Configuration
output Connectors
Model
Pinout
Code
Profile & Dimension
1
2
3
4
6
11
Suggested Mating
Description
Connector
Tip:
Positive
Sleeve:
Negative
Switchcraft
#750
Plug or
Equivalent
Switchcraft
#41
Jack or
Equivalent
Center
Contact:
Positive
Switchcraft
#S760
Switchcraft
#722
Plug or
Equivalent
Jack or
Equivalent
Center
Contact:
Positive
Switchcraft
#760
Plug or
Equivalent
Switchcraft
#712A
Jack or
Equivalent
(1) GND
(2) COM
(3) +5V
(4) -12V
6 Pin Molex
Connector
(Housing 26-03
0.045 square pin
on 0.156 centers.
(Ref: Molex Series
-4061;
Terminal 08-50
2220, 5273, 5274)
(5) Key
(6) +12V
(1) GND
(2) Pos
-0187)
3-pin Female
Slim-Line
(3) Neg
Series
Tip:
Positive
Switchcraft
#850
Switchcraft
TR-2A or
Plug or
Equivalent
MDPC-2A-RA
Jack
Switchcraft
SL Series
All dimensions are Typical. Exact dimensions available upon request.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
P2
Output Configuration
Output Configuration
Output Configuration
Output Configuration
Output Connectors
Output Connectors
Model
Model
Profile & Dimension
Profile & Dimension
12
12
15
15
16
16
17
17
19
19
20
20
Pinout
Code
Pinout
Code
(1) COM
Description
Description
5-Pin DIN
5-Pin
DIN
180˚ Male
(1)
(2) COM
GND
(2)
(3) GND
+5V
(3)
(4) +5V
-12V
(4) -12V
(5)
+12V
(5) +12V
(1) GND
(1)
GND
(2)(5)
G/S
(2)(5)
G/S
(3) +5V
(3) +12V
+5V
(4)
(4)
(6) +12V
-12V
(6) +5V
-12V
(7)
(7) +12V
+5V
(1)
(1) +12V
(2)(4)
COM
(2)(4)
COM
(3) +5V
(3)
(5) +5V
GND
(5)
(6) GND
-12V
(6)
(7) -12V
+5V
(7) +5V
(1)
GND
(1)
(2) GND
COM
(2) COM
(3)
+5V
(3) -12V
+5V
(4)
(4) Key
-12V
(5)
(5) +12V
Key
(6)
(6) +12V
*1
*1
*2
*2
Suggested Mating
Connector
Suggested
Mating
Connector
Various
style of
Various
style
of
straight or
right
180˚ Male
Connector
Connector
straight
or right
angle panel
or p.c.
angle
panel
mounted DINor p.c.
mounted DIN
Connectors
Connectors
7-Pin DIN
7-Pin
DIN
Female
Female
Connector
Connector
Various style of
Various
style
of
straight or
right
straight
or right
angle panel
or p.c.
angle
panel
mounted
DINor p.c.
mounted
DIN
Connectors
Connectors
7-Pin DIN
7-Pin
Male DIN
Various style of
Various
style
of
straight or
right
Male
Connector
Connector
straight
or right
angle
panel
or p.c.
angle
panel
mounted
DINor p.c.
mounted
DIN
Connectors
Connectors
6 Pin Molex
6
Pin Molex
Connector
Connector
(Housing 26-03
(Housing
-4041; 26-03
-4041; 08-50
Terminal
Terminal
-0187) 08-50
-0187)
14
Pin Hirose
14 Pin Hirose
Locking
Locking
Connector
0.045 square pin
0.045
square
pin
on 0.156
centers.
on
0.156
centers.
(Ref:
Molex
Series
(Ref:
2220,Molex
5273, Series
5274)
2220, 5273, 5274)
Hirose RP5
Hirose
RP5
type Receptacle
type Receptacle
Connector
4 Pin Molex
4
Pin Molex
Connector
Connector
(Housing
(Housing
26-03-4041;
26-03-4041;
Terminal
0.045 square pin
0.045
square
pin
on 0.156
centers.
on
0.156
centers.
(Ref: Molex Series
(Ref: Molex
2220,
5273, Series
5274)
2220, 5273, 5274)
Terminal
08-50-0187)
08-50-0187)
All dimensions are Typical. Exact dimensions available upon request.
All
are Typical.
Exact(2),(6),(10):+5V,
dimensions available
upon request.
*1 :dimensions
Power Supply
/ (1):-12V,
(3),(7),(11),(14):COM,
(4),(8):GND, (9):+12V, (5),(12):N.C
*1
(3),(7),(11),(14):COM,
(4),(8):GND,
(9):+12V,
(5),(12):N.C
*2 : Power Supply / (1):-12V,
(1):GND, (2),(6),(10):+5V,
(2),(3):AC, (4):CT,
Power Supply / (1),(3):DC,
(2):COM,
(4):GND
*2 : Power Supply / (1):GND, (2),(3):AC, (4):CT, Power Supply / (1),(3):DC, (2):COM, (4):GND
BridgePower Corporation
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
http://www.bridgepower.co.kr
P3
P3
Output Configuration
Output Configuration
Output Connectors
Model
Pinout
Code
Profile & Dimension
21
22
*3
(1) +12V
(2) COM
(3) +5V
(4) -12V
23
26
(2)(4) COM
(3)(7) +5V
(5) GND
0.045 square pin
on 0.156 centers.
(Ref: Molex Series
2220, 5273, 5274)
6-Pin DIN
Male
Connector
Various style of
straight or right
angle panel or p.c.
mounted DIN
Connectors
8-Pin DIN
Male
Connector
(6) -12V
(1)(2) +5V
(3) +12V
(6) GND
Connector
3 Pin Molex
Connector
(Housing
26-03-4030;
Terminal
08-50-0187)
(5)(6) COM
(1)(8) +12V
Suggested Mating
Description
Various style of
straight or right
angle panel or p.c.
mounted DIN
Connectors
9-Pin AMP
Mate-N-Lock
Connector
AMP 641971-1
Pin Header
Assembly
15-Pin D
Subminiature
AMP or TRW
15-Pin D
Receptacle
Subminiature
Plug
Housing
AMP
AMP 87631-1
O/M Pin AMP
87309-8,9
86492-9
Header Assy
AMP
102618-1
(7)(8) COM
(9) -12V
28
*4
Optional
29
87107-6
All dimensions are Typical. Exact dimensions available upon request.
*3 : Transformer / (1),(3):AC, (2):GND, Power Supply / (1):DC, (2):COM, (3):GND
*4 : (1),(2),(3),(9):+5V, (4),(5),(7),(11):COM, (6):+12V, (8):-12V, (14),(15):GND, (10),(12),(13):NC
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
P4
Output Configuration
Output Configuration
Output Connectors
Model
Pinout
Code
Profile & Dimension
Optional
Suggested Mating
Description
Connector
Plug-Connector
Ovemold
613-1210
Pin AMP
P83-31767
30
CHO-SORB
Optional
CORE 613-1326
Ferrite material Overmold core
OD
680 / 562
Inside Dia
370 / 265
31
Length
9 Position
Socket
AMP 66504-4
with Shield
and
Ferrule
AMP 747579
without Shield
Recepacle
AMP 747951
SHOGYO
SJ-200
AMP Connector
32
33
34
35
*5
Center
Contact:
SHOGYO
Connector
Positive
OP/218/5
(1) GND
(2) +25V
Connector
Housing
(3) +8V
(4) COM
4 Pos. AMP
35779-1 and
Strain Relief
AMP 641776-2
5 circuit
Molex 03-04
##
Teminal
Molex 5556
-5558 with O/M
(1) GND
(2) COM
(3) COM
(4) +5V
(5) +5V
1.12 / 1.12
Socket
AMP 350570-1
Overmold tooling
Ault 1337
Colle 18-22GA
All dimensions are Typical. Exact dimensions available upon request.
*5 : (1),(4),(7),(8):N/C, (2),(3):+/-VDC, (5),(9):COM, (6):Heat Sink, Shell Chassis Ground
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
P5
Output Configuration
Output Configuration
Output Connectors
Model
Profile & Dimension
Pinout
Code
41
42
43
44
Connector
Optional
Miniature
straight cord
plug
Switchcraft
12CL5M
5 Pin at 240˚
Pin Dia. 059
Cord 22GA max
Center
Contact:
Positive
Molded right
angle plug
Switchcraft
Switchcraft Jack
712A or
Equivalent
36
40
Suggested Mating
Description
760 or
Equivalent
Center
Switchcraft
Switchcraft Jack
712 or
Equivalent
Contact:
Positive
#S760 Plug
or Equivalent
Center
Contact:
Molded straight
plug equivalent
Positive
Switchcraft
S760
Center
Contact:
Molded straight
plug equivalent
Switchcraft Jack
712A or
Positive
Switchcraft
##
Equivalent
Center
Contact:
Positive
Molded straight
plug equivalent
Switchcraft
S760K
Switchcraft Jack
722A or
Equivalent
Switchcraft Jack
712 or
Equivalent
All dimensions are Typical. Exact dimensions available upon request.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
P6
Output Configuration
Output Configuration
Output Connectors
Model
Profile & Dimension
45
48
49
50
51
60
Pinout
Code
Suggested Mating
Description
Connector
Center
Contact:
Positive
Miniature
Switchcraft Jack
molded Locking 712A or
power Plug
Equivalent
Switchcraft
760K or
Equivalent
Center
Contact:
Positive
Snap and Lock
Power Plug
3-Pin wires
18AWG max.
Kycon
KPJ-3S
Socket or
Equivalent
PIN3-24AWG
Kycon Kpp-3p
Snap and Lock
Power Plug
Kycon
KPJ-4S
Positive
4-Pin
Prefer 20AWG
Socket or
Equivalent
Molded
Micro-Fit
3.0
Receptacle
Molex
Overmold Ault
4 Pos, Max.
wire 20AWG
Prefer 22AWG
Molex
Plug Molex
43020-0400
or 0401
Molded
Micro-Fit
43025-0400
Overmold Ault
6 Pos, Molex
Center
Contact:
Receptacle
39-01-2060
Max. AWG-18
Plug Molex
39-01-2061
or 3063
or Equivalent
Molded
Mini-Pin
Connector
Mini-Pin
Overmold
22AWG max.
Cinch MD-4S
All dimensions are Typical. Exact dimensions available upon request.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
P7
Output Configuration
Output Configuration
Output Connectors
Model
Profile & Dimension
61
62
63
65
66
67
Pinout
Code
Description
Molded
Mini-Pin
Connector
Mini-Pin
Overmold
22AWG max.
Cinch MD-5S
Molded
Mini-Pin
Connector
Mini-Pin
Overmold
22AWG max.
Cinch MD-6S
Molded
Mini-Pin
Mini-Pin
Overmold
Cinch MD-7S
Connector
24AWG max.
Stripped
or ribbed
lead
positive
Strip
and
Tin
Available
20,18 AWG
Center
Contact:
Switchcraft
S760 Plug style
Switchcraft Jack
722A or
Positive
or equivalent
Equivalent
Center
Contact:
Positive
Switchcraft
760 Plug style
or equivalent
Switchcraft Jack
712A or
Equivalent
Suggested Mating
Connector
All dimensions are Typical. Exact dimensions available upon request.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
P8
Output Configuration
Output Configuration
Output Connectors
Model
Profile & Dimension
68
69
Pinout
Code
Suggested Mating
Description
Connector
Center
Contact:
Positive
5.5 * 2.1 * 9mm
.218 * .080 *
* .375
Phone plug with
Hi-Retention
Option
Center
Contact:
5.5 * 2.5 * 9mm
Phone plug with
.218 * .080 *
* .375
Hi-Retention
Option
Positive
All dimensions are Typical. Exact dimensions available upon request.
BridgePower Corporation
Tel : +82-31-299-1234
Fax : +82-31-224-0566
http://www.bridgepower.co.kr
P9
Memo
History
Company History
Memo
2010. 03
2009. 12
2009. 01
2008. 11
2007. 04
2006. 02
2005. 11
2005. 05
2004. 01
2003. 01
2002. 11
2001. 05
2000. 08
2000. 02
1999. 01
1999. 03
1999. 01
1998. 06
1996. 07
1995. 05
1993 09
1993. 09
1993. 09
1991. 11
1990. 12
1988 ‐
1987. 07
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
China factory expansion (Facilitiy & Equipment)
WTDP registered (UL)
ISO14001 registered. Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Registered as major supplier (power supply) to Samsung. Satisfied with ECO design partnership. PL Insurance insured (USD500,000) Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) Factory approved by china CCC Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
Business Field Expansion (Total Power Solution) Nominated as superior exporting company (City government) ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Export record (over USD10M) Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) Factory approval and listed products by Korean safety Awarded prize (Korea president) as prominent export company. Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Transformer and Linear Power Supply manufacturing Established AULT KOREA CORPORATION. BridgePower Corporation
Korea Factory
BridgePower Corporation Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
Memo
History
Memo
History
Company History
Memo
2010. 03
2009. 12
2009. 01
2008. 11
2007. 04
2006. 02
2005. 11
2005. 05
2004. 01
2003. 01
2002. 11
2001. 05
2000. 08
2000. 02
1999. 01
1999. 03
1999. 01
1998. 06
1996. 07
1995. 05
1993 09
1993. 09
1993. 09
1991. 11
1990. 12
1988 ‐
1987. 07
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
China factory expansion (Facilitiy & Equipment)
WTDP registered (UL)
ISO14001 registered. Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Registered as major supplier (power supply) to Samsung. Satisfied with ECO design partnership. PL Insurance insured (USD500,000) Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) Factory approved by china CCC Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
Business Field Expansion (Total Power Solution) Nominated as superior exporting company (City government) ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Export record (over USD10M) Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) Factory approval and listed products by Korean safety Awarded prize (Korea president) as prominent export company. Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Transformer and Linear Power Supply manufacturing Established AULT KOREA CORPORATION. BridgePower Corporation
Korea Factory
BridgePower Corporation Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
Memo
History
Memo
History
Company History
Memo
2010. 03
2009. 12
2009. 01
2008. 11
2007. 04
2006. 02
2005. 11
2005. 05
2004. 01
2003. 01
2002. 11
2001. 05
2000. 08
2000. 02
1999. 01
1999. 03
1999. 01
1998. 06
1996. 07
1995. 05
1993 09
1993. 09
1993. 09
1991. 11
1990. 12
1988 ‐
1987. 07
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
China factory expansion (Facilitiy & Equipment)
WTDP registered (UL)
ISO14001 registered. Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Registered as major supplier (power supply) to Samsung. Satisfied with ECO design partnership. PL Insurance insured (USD500,000) Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) Factory approved by china CCC Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
Business Field Expansion (Total Power Solution) Nominated as superior exporting company (City government) ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Export record (over USD10M) Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) Factory approval and listed products by Korean safety Awarded prize (Korea president) as prominent export company. Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Transformer and Linear Power Supply manufacturing Established AULT KOREA CORPORATION. BridgePower Corporation
Korea Factory
BridgePower Corporation Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
Memo
History
Memo
History
Company History
Memo
2010. 03
2009. 12
2009. 01
2008. 11
2007. 04
2006. 02
2005. 11
2005. 05
2004. 01
2003. 01
2002. 11
2001. 05
2000. 08
2000. 02
1999. 01
1999. 03
1999. 01
1998. 06
1996. 07
1995. 05
1993 09
1993. 09
1993. 09
1991. 11
1990. 12
1988 ‐
1987. 07
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
China factory expansion (Facilitiy & Equipment)
WTDP registered (UL)
ISO14001 registered. Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Registered as major supplier (power supply) to Samsung. Satisfied with ECO design partnership. PL Insurance insured (USD500,000) Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) Factory approved by china CCC Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
Business Field Expansion (Total Power Solution) Nominated as superior exporting company (City government) ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Export record (over USD10M) Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) Factory approval and listed products by Korean safety Awarded prize (Korea president) as prominent export company. Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Transformer and Linear Power Supply manufacturing Established AULT KOREA CORPORATION. BridgePower Corporation
Korea Factory
BridgePower Corporation Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
Memo
History
Memo
History
Company History
Memo
2010. 03
2009. 12
2009. 01
2008. 11
2007. 04
2006. 02
2005. 11
2005. 05
2004. 01
2003. 01
2002. 11
2001. 05
2000. 08
2000. 02
1999. 01
1999. 03
1999. 01
1998. 06
1996. 07
1995. 05
1993 09
1993. 09
1993. 09
1991. 11
1990. 12
1988 ‐
1987. 07
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
China factory expansion (Facilitiy & Equipment)
WTDP registered (UL)
ISO14001 registered. Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Registered as major supplier (power supply) to Samsung. Satisfied with ECO design partnership. PL Insurance insured (USD500,000) Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) Factory approved by china CCC Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
Business Field Expansion (Total Power Solution) Nominated as superior exporting company (City government) ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Export record (over USD10M) Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) Factory approval and listed products by Korean safety Awarded prize (Korea president) as prominent export company. Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Transformer and Linear Power Supply manufacturing Established AULT KOREA CORPORATION. BridgePower Corporation
Korea Factory
BridgePower Corporation Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
Memo
History
Memo
History
Company History
Memo
2010. 03
2009. 12
2009. 01
2008. 11
2007. 04
2006. 02
2005. 11
2005. 05
2004. 01
2003. 01
2002. 11
2001. 05
2000. 08
2000. 02
1999. 01
1999. 03
1999. 01
1998. 06
1996. 07
1995. 05
1993 09
1993. 09
1993. 09
1991. 11
1990. 12
1988 ‐
1987. 07
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
China factory expansion (Facilitiy & Equipment)
WTDP registered (UL)
ISO14001 registered. Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. Registered as major supplier (power supply) to Samsung. Satisfied with ECO design partnership. PL Insurance insured (USD500,000) Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) Factory approved by china CCC Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
Business Field Expansion (Total Power Solution) Nominated as superior exporting company (City government) ISO9001 registered by UL (Jan. ’99) Established R&D LAB & TCP Lab., ISO9002 registered by UL and BSI co‐registered firm Export record (over USD10M) Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) Factory approval and listed products by Korean safety Awarded prize (Korea president) as prominent export company. Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing Transformer and Linear Power Supply manufacturing Established AULT KOREA CORPORATION. BridgePower Corporation
Korea Factory
BridgePower Corporation Wendeng Jeil Electronics
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
Memo
History
Certificate
History
Company History
ISO9001 & ISO14001 Certificate
2010. 03
2009. 12
2009. 01
Full line‐up in energy star Level IV,V and EISA V products
ISO9001 & ISO14001 registered by QS CERT
ISO9001 & ISO14001 registered by TUV
WTDP registered by UL
2008. 11
Move to new factory,Suwon IT Complex and change company name(brand)
BridgePower(964 Gosaek dong Gwonseon gu Suwon si Gyeonggi do 441 813 Korea)
BridgePower(964, Gosaek‐dong, Gwonseon‐gu ,Suwon‐si, Gyeonggi‐do, 441‐813, Korea)
2007. 04
Nominated as INNO‐BIZ company (Business Adminstration of Gyeonggi‐Do)
2006. 02
China factory expansion (Facilitiy & Equipment)
2005. 11
WTDP registered (UL)
2005. 05
ISO14001 registered. 2004. 01
Registered as major supplier(power supply) to LG. Satisfied with ECO design partnership. 2003. 01
Registered as major supplier (power supply) to Samsung. Satisfied with ECO design partnership. BridgePower ISO9001
BridgePower ISO14001
Wendeng Jeil ISO9001
Wending Jeil ISO14001
2002. 11
PL Insurance insured (USD500,000) 2001. 05
Factory Move to new building (26‐6 Wauri Bong‐Dam Eup, HwaSung‐Si, Gyeonggi‐do, Korea) 2000. 08
Factory approved by china CCC 2000. 02
Established china factory (Wendeng Jeil Electronics Co.,Ltd. / In ShanDong‐Shung)
1999. 01
Business Field Expansion (Total Power Solution) 1999. 03
Nominated as superior exporting company (City government) 1999. 01
ISO9001 registered by UL (Jan. ’99) 1998. 06
Established R&D LAB & TCP Lab., 1996. 07
ISO9002 registered by UL and BSI co‐registered firm 1995. 05
Export record (over USD10M) 1993 09
1993. 09
Factory approval and listed products by MITI(Japan)
Factory approval and listed products by MITI(Japan) 1993. 09
Factory approval and listed products by Korean safety UL
UL
CE
CSA
K MARK
U.S.A
U.S.A
Europe
Canada
Korea
1991. 11
Awarded prize (Korea president) as prominent export company. 1990. 12
Expand biz items (Switching Mode Power Supply, Battery Charger) manufacturing 1988 ‐
Transformer and Linear Power Supply manufacturing 1987. 07
Established AULT KOREA CORPORATION. Major Safety Approvals
CCC
PSE
BSMI
INMETRO
NOM
China
Japan
Taiwan
Brazil
Mexico
SAA
STQC
RoHS
BridgePower Corporation
Australia
Korea Factory
BridgePower Corporation India
Safety
Wendeng Jeil Electronics
Singapore
BridgePower China Factory
Tel : +82‐31‐299‐1234 Fax : +82‐31‐224‐0566
http://www.bridgepower.co.kr
GS
Germany
Certificate
History
BridgePower Corp.
Beongil 16, Omokcheon-rho, Gwonsun-gu, Suwon-si, Gyeonggi-do, 441-813, Korea
Tel 82-31-299-1234 Fax 82-31-224-0566 www.bridgepower.co.kr
Download