IEC System for Conformity Testing and Certification of Electrotechnical equipment and Components TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING IEC 60730-1:2010-03, Edition 4.0 Automatic electrical controls for household and similar use Part 1: General requirements R = Required to be at Lab S = May be subcontracted W = May be witnessed at MTL SF = Specialized Facility 3PPS = Three Phase Power Supply required Clause Measurement/testing 3 4 5 6 7 8 General requirements General notes on tests Rating Classification Information Protection against electric shock 9 Provision of protective earthing 10 Terminals and terminations 11 Construction requirements 2013-02-08 Testing / measuring equipment / material needed Subcontracting None None None None None Test finger (Fig. 2), force gauge, test pin (Fig. 1), milliammeter, voltmeter, ruler, micrometer Ammeter, voltmeter Appropriate material analyzing equipment (e.g. scanning electron microscope, energy dispersive x-ray spectrometer) According to IEC 60998, Torque tester, force gauge tester, screwdriver, micrometer, ruler, flexing tester Electric strength tester, HV test supply, isolation transformer, insulation tester, DC voltage supply, flexing tester, voltmeter, ammeter, freezer chamber, temperature recorder, torque tester, force gauge, time clock, test fingernail R 1/4 R S R R IEC 60730-1, Ed.4.0 IEC System for Conformity Testing and Certification of Electrotechnical equipment and Components Clause Measurement/testing 12 Moisture and dust resistance 13 14 Electric strength and insulation resistance Heating 15 Manufacturing deviation and drift 16 17 Environmental stress Endurance 18 Mechanical strength 19 20 Threaded parts and connections Creepage distances, clearances and distances through solid insulation 21 Resistance to heat, fire and tracking 22 Resistance to corrosion 2013-02-08 Testing / measuring equipment / material needed Subcontracting According to IEC 60529, electric strength tester, conditioning chambers: heaterhumidity, leakage current meter Insulation tester, electric strength tester, leakage current tester Temperature meter/recorder, fine wire thermocouples, winding resistance measurement system, environmental chambers (heat, freeze), current loads per ratings, voltmeter, ammeter Voltmeter, ammeter Equipment as required by Part 2-x depending on the type of control such as e.g. environmental chamber (heat, cold, humidity), temperature meter/recorder, humidity meter/recorder, pressure meter/recorder, etc. Remark: For those types of controls for which the atmospheric pressure is relevant for the determination of the manufacturer deviation and drift the atmospheric pressure has to be measured by a pressure meter or alternatively it is acceptable to get the information about the atmospheric pressure online via local metrological service. Environmental chambers – heat, freeze, humidity Environmental chambers – heat, freeze, humidity. Voltmeter, ammeter, power analyzer meter, oscilloscope, inductive loads, resistive loads, pilot duty loads, motor loads. Activation source and cycling mechanism as required by the Part 2. Apparatus in IEC 60068-2-75, impact tester (Fig. 4), tumbling barrel (Fig. 5), force tester, torque tester, pull tester All as required by Part 2 Screwdrivers, torque tester Measuring ruler, force tester, test finger (Fig. 2), impulse voltage tester, electric voltage tester, insulation resistance meter, oscilloscope, electric strength tester, micrometer Ball pressure test apparatus, glow wire test apparatus, environmental chamber or heating cabinet, tracking test apparatus, voltmeter, ammeter Humidity chamber, heating cabinet R 2/4 R R R R R 3PPS R R R R R IEC 60730-1, Ed.4.0 IEC System for Conformity Testing and Certification of Electrotechnical equipment and Components Clause Measurement/testing Testing / measuring equipment / material needed Subcontracting S Normal operation EMC requirements – immunity Abnormal operation Guide of the use of electronic disconnection Indelibility of Marking Measurement Guide Cotton for Mercury Switch Test Heat, fire and tracking Apparatus in accordance with CISPR 14-1. Equipment in accordance with Clause 17, oscilloscope Test apparatus in accordance with IEC 60742 and other IEC component standards Refer to Annex H Refer to Annex H Voltmeter, ammeter, electric strength tester Refer to Annex H Petroleum spirit, water, cloth, apparatus described in figure 8 None Common as described in Annex C Informative guide – None R R R - Circuit for measurement leakage current Heat-Fire Resistance Categories Circuit apparatus according to Figure E1 Informative guide – None R - Heat-Fire Resistance Tests Requirements for Electronic Controls Protection against electric shock Constructional requirements Electric strength and insulation resistance Endurance Mechanical Strength Creepage distance, clearance and distance through insulation Resistance to heat, fire and tracking EMC requirements – emission Normal Operation Glow-wire test apparatus, PTI Test apparatus Refer to Annex H, sub-clauses below: Leakage current meter Ammeter, voltmeter, chart recorder Same as Clause 13 above Thermal cycling test apparatus Refer to Clause 18 above Refer to Clause 20 above R R R R R R R Refer to Clause 21 above Refer to Clause 23 above Oscilloscope, ammeter, voltmeter R S R 23 EMC requirements – emission 24 Components 25 26 27 28 Annex A Annex B Annex C Annex D S (informative) Annex E Annex F (informative) Annex G Annex H H8 H11 H13 H17 H18 H20 H21 H22 H23 2013-02-08 3/4 IEC 60730-1, Ed.4.0 IEC System for Conformity Testing and Certification of Electrotechnical equipment and Components Clause H26 H27 H28 Annex J Annex K Measurement/testing Testing / measuring equipment / material needed Subcontracting S Abnormal Operation Guide on use of electronic disconnection Requirements for controls using thermistors Nominal voltages Environmental chamber, voltage dips and short voltage interruption apparatus, variable voltage supply, 3-phase auto-transformer, surge test apparatus, fast transient/burst test apparatus, ring wave surge test apparatus, conducted radiofrequency test apparatus radiated EM field test apparatus Voltmeter, ammeter, oscilloscope, temperature meter None Same which are used for clauses 8 through 28 None R R - Overvoltage categories Typical usage None None - Pollution degree Printed circuit board coating performance test Printed circuit board coating performance test Explanatory notes for surge immunity test None Heating chamber, humidity chamber, environmental cycling chamber, electric strength tester Freezing chamber, environmental cycling chamber, electric strength tester, freezing chamber None R Guidance for applying Clause 20 None - Requirements for SELV and PELV Requirements for relays when used as controls in IEC 60335 appliances None Same which are used for clauses 7 through 28 EMC requirements – immunity (informative) Annex L Annex M (informative) Annex N Annex P Annex Q Annex R R - (informative) Annex S (informative) Annex T Annex U 2013-02-08 4/4 R 3PPS IEC 60730-1, Ed.4.0