Cole Hersee

advertisement
Solenoids Section E
Cole Hersee
R
Solenoids
Intermittent Duty
Continuous Duty
Consult factory for switches having specifications other than those shown in this catalog.
53
®
Cole Hersee
200 amp Continuous Duty Solenoids • SPST • Normally open contacts • One circuit: Off-On
INSULATED
No. 24143
12 volt
Rated at 200 amps.
Contacts: silver.
Housing: plated steel.
Contact terminal: 5/16"-24 thread.
Bracket mounting holes: 5/16" x 19/32",
2 13/64" on centers.
No. 24144
24 volt
Rated at 200 amps
(carry only, not to break
200 amps at 24 VDC).
Intermittent Duty Solenoids • SPST • Normally open contacts • One circuit: Off-On
Contacts: copper.
Housings: plated steel and phenolic.
Terminals: copper; small ignition and ground terminals
are 10-32 thread, large contact terminals are 5⁄16" - 24
thread, with hex nuts and lock washers included.
Intermittent Duty • 120 amps make • 65 amps break • 10 secs. on - 30 min. off
No. 24008
Steel Housing
24
Bracket mounting holes
5/16" x 19/32", 2 13/64"
on centers.
Volts
BAT.
24
No. 24104
Steel Housing
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
INSULATED
Intermittent Duty • 750 amps make • 100 amps break • 10 secs. on - 20 min. off
No. 24037
Steel Housing
12
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
GROUNDED
No. 24022
Phenolic Housing
Bracket mounting
holes 9/32" x 25/64",
2 7/64" on centers.
For plasticized model
see No. 24071 pg. 58.
No. M-202
Steel Housing
12
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
MARINE CONSTRUCTION
Clear dichromate protective finish.
Brass hex nuts and lock washers.
GROUNDED
No. 24044
Steel Housing
12
Bracket mounting
holes 5/16" x 19/32",
2 1/8" on centers.
Volts
O No. 24020
Phenolic Housing
Bracket mounting holes
9/32" x 11/16", 2 1/8" on
centers.
GROUNDED
Resistor Shorting
Circuit
12
Volts
No. 24103
Steel Housing
No. 24021
Phenolic Housing
Contact terminal
5/16"-24 thread,
bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Contact terminal
5/16"-24 thread,
bracket mounting
holes 9/32" x 1/2",
2 13/64" on centers.
GROUNDED
Resistor Shorting
Circuit
O No. 24138
Phenolic Housing
Contact terminal
5/16"-18 thread,
bracket mounting holes
9/32" x 11/16", 2 7/64"
on centers.
12
Volts
GROUNDED
54
With breather
O Minimum order quantity may apply. Please consult factory or current price list.
Solenoids Section E
Intermittent Duty Solenoids • SPST • Normally open contacts • One circuit: Off-On
Contacts: copper.
Housings: plated steel and phenolic.
Terminals: copper; small ignition and ground terminals
are 10-32 thread, large contact terminals are 5⁄16" - 24
thread, with hex nuts and lock washers included.
Intermittent Duty • 750 amps make • 100 amps break • 10 secs. on - 20 min. off
12
BAT.
Volts
No. 24046
Steel Housing
No. 2430
Phenolic Housing
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Bracket mounting
holes 9/32" x 1/2",
2 13/64" on centers.
INSULATED
For plasticized model see No. 24077 pg. 58.
No. 24023
Phenolic Housing
No. 24047
Steel Housing
12
Bracket mounting
holes 9/32" x 3/4",
2 13/64" on centers.
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
For plasticized model see No. 24076 pg. 58.
No. M-200
Steel Housing
12
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
12
BAT.
No. 24060
Steel Housing
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
Intermittent Rating: 750 amps make,
100 amps break
10 seconds On,
30 minutes off
ARINE
U
®
7
O ST E
W D 7 0I T C
ER SW
LI
P
12
M
HB
No. M-200-01
Steel Housing
UL listed ISO 8846
MARINE
Intermittent Duty • 750 amps make • 100 amps break • 10 secs. on - 20 min. off
No. 24041
Steel Housing
6
Bracket mounting
holes 5/16" x 19/32",
2 1/8" on centers.
Volts
6
6
GROUNDED
O No. 24055
Steel Housing
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
Bracket mounting
holes 5/16" x 19/32",
2 1/8" on centers.
Volts
GROUNDED
BAT.
No. 24039
Steel Housing
O No. 24043
Steel Housing
6
Bracket mounting
holes 5/16" x 19/32",
2 1/8" on centers.
Volts
INSULATED
O Minimum order quantity may apply. Please consult factory or current price list.
55
®
Cole Hersee
Continuous Duty Solenoids • SPDT • Normally open and normally closed contacts
For forward and reverse systems in golf carts, garden tractors, fork lift trucks, winch operation, etc.
Housings: steel.
Contact terminal: 5⁄16"-24 thread.
Bracket mounting holes: 5⁄16" x 19⁄32", 2 13⁄64" on centers.
Continuous Duty
Normally closed contacts • 35 amps
Normally open contacts • 85 amps
12
36
Volts
Volts
INSULATED
No. 24400
INSULATED
24
No. 24401
For
plasticized
model see
No. 24401-04
page 58.
12
Volts
Volts
INSULATED
GROUNDED
No. 24402
No. 24401-01
Continuous Duty Solenoid • SPST • Normally closed contacts
Continuous Duty
Normally closed contacts • 35 amps
12
Volts
INSULATED
No. 24420
Latching Solenoid
Continuous Duty • For 12 VDC systems • Requires less than 3.5 amps to operate • Compact, mounts in tight locations.
No heat is generated because coil is taken out of circuit.
Electrical Rating
110 amps continuous (carry only).
No. 24200
Case: plated steel.
Terminals: small terminals 10-32
thread, large terminals 5/16"-24 thread,
hex nuts and lockwashers included.
Bracket mounting holes: .281"
(7.16mm) x .310" (7.87mm),
2.20" (55.88mm) on centers.
How it works:
1. Actuate a momentary switch to close the solenoid's
contacts, allowing current to flow.
2. Once the momentary switch is actuated, the circuit
remains closed.
3. A second actuation of the momentary switch re-opens the
circuit.
56
Application Information
Remotely operated battery isolator
Can be used to isolate one battery from another in a two
battery system and prevent battery power loss or drain. The
No. 24200 will not produce voltage drop typically associated
with battery isolators because of its electro-mechanical
characteristics (i.e. not relying on diodes) to perform the
isolating function. In this application, No. 24200 is used in
conjunction with a momentary switch.
Remote battery disconnect switch.
Can be used as a battery disconnect switch where vehicle
wiring constraints do not allow for the location of heavy
gauge wires. In this application, No. 24200 is used in
conjunction with a momentary switch located on a panel or
dash.
O Minimum order quantity may apply. Please consult factory or current price list.
Solenoids Section E
Continuous Duty Solenoids • SPST • Normally open contacts • One circuit: Off-On
Contacts: copper.
Housings: plated steel.
Ignition and ground terminals: copper, 10-32 thread, hex nuts and lock washers included.
Contact terminals: copper, 5⁄16" - 24 thread, hex nuts and lock washers included.
Continuous Duty • 85 amps
No. 24080
Steel Housing
Volts
INSULATED
For plasticized model see No. 24135 pg. 58.
Bracket mounting holes
9/32" x 11/16", 2 7/64"
on centers.
36
Bracket mounting holes
9/32" x 11/16", 2 7/64"
on centers.
Volts
M
ARINE
U
®
7
O ST E
W D 7 0I T C
ER SW
LI
P
No. 24080-01
Steel Housing
HB
36
UL listed ISO 8846
MARINE
Continuous Rating: 65 amps 36 VDC
Intermittent Rating: 120 amps make,
65 amps break
10 seconds On,
30 minutes off
INSULATED
Continuous Duty • 85 amps
24
24
24
Volts
Volts
Volts
GROUNDED
BAT.
INSULATED
INSULATED
No. 24124 Steel Housing
No. 24063 Steel Housing
No. 24107 Steel Housing
Bracket mounting holes 5/16" x 19/32", 2 13/64" on
centers.
Bracket mounting holes 5/16" x 19/32", 2 13/64" on
centers.
For plasticized model see No. 24063-08 pg. 58.
Bracket mounting holes 5/16" x 19/32", 2 13/64" on
centers.
Continuous Duty • 85 amps
No. 24106
Steel Housing
12
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Volts
12
BAT.
Volts
INSULATED
Bracket mounting holes
5/16" x 19/32",
2 1/8" on centers.
Volts
GROUNDED
12
No. 24082
Steel Housing
GROUNDED
No. 24115
Steel Housing
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
No. 24059
Steel Housing
12
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
For plasticized model see No. 24117 pg. 58.
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
ARINE
U
®
HB
12
M
LI
P
No. 24059-08
Steel Housing
7
O ST E
W D 7 0I T C
ER SW
UL listed ISO 8846
MARINE
Continuous Rating: 65 amps 12 VDC
Intermittent Rating: 750 amps make,
100 amps break
10 seconds On,
30 minutes off
Continuous Duty • 85 amps
O No. 24105
Steel Housing
6
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers)
Volts
GROUNDED
No. 24097
Steel Housing
6
Bracket mounting
holes 5/16" x 19/32",
2 13/64" on centers.
Volts
INSULATED
O Minimum order quantity may apply. Please consult factory or current price list.
57
Cole Hersee
®
Plasticized Steel Housing Solenoids
Intermittent Duty • SPST • Normally open contacts • One circuit: Off-On
Intermittent Duty • 750 amps make • 100 amps break • 10 secs. on - 20 min. off
12
12
Volts
BAT.
12
Volts
INSULATED
Volts
GROUNDED
INSULATED
No. 24076
No. 24077
No. 24071
Bracket mounting holes 5/16" x 19/32", 2 13/64" on
centers. Contact terminal: 5⁄16"-24 thread.
Bracket mounting holes 5/16" x 19/32", 2 13/64" on
centers. Contact terminal: 5⁄16"-24 thread.
Bracket mounting holes 5/16" x 19/32", 2 13/64" on
centers. Contact terminal: 5⁄16"-24 thread.
Continuous Duty • SPST• Normally open contacts • One circuit: Off-On
Continuous Duty • 85 amps
No. 24135
Volts
INSULATED
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Contact terminal: 5⁄16"-24 thread.
M
36
No. 24135-01
7
O ST E
W D 7 0I T C
ER SW
UL listed ISO 8846
MARINE
M
No. 24063-08
24
Volts
INSULATED
Continuous Rating: 65 amps 36 VDC
Intermittent Rating: 120 amps make,
65 amps break
10 seconds On,
30 minutes off
ARINE
U
®
7
O ST E
W D 7 0I T C
ER SW
LI
P
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Contact terminal: 5⁄16"-24 thread.
®
HB
INSULATED
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Contact terminal: 5⁄16"-24 thread.
U
LI
P
Volts
ARINE
HB
36
UL listed ISO 8846
MARINE
Continuous Rating: 65 amps 24 VDC
Intermittent Rating: 120 amps make,
65 amps break
10 seconds On,
30 minutes off
Continuous Duty • 85 amps
No. 24117
12
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Contact terminal: 5⁄16"-24 thread.
Volts
INSULATED
M
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Contact terminal: 5⁄16"-24 thread.
Volts
INSULATED
U
®
7
O ST E
W D 7 0I T C
ER SW
HB
No. 24117-01
LI
P
12
ARINE
UL listed
Continuous Rating: 65 amps 12 VDC
Intermittent Rating: 750 amps make,
100 amps break
ISO 8846
10 seconds On,
MARINE
30 minutes off
Continuous Duty • SPDT • Normally open and normally closed contacts
Continuous Duty • normally closed contacts 35 amps • normally open contacts 85 amps
12
No. 24401-04
Bracket mounting holes
5/16" x 19/32",
2 13/64" on centers.
Contact terminal: 5⁄16"-24 thread.
Volts
INSULATED
58