Solenoids Section E Cole Hersee R Solenoids Intermittent Duty Continuous Duty Consult factory for switches having specifications other than those shown in this catalog. 53 ® Cole Hersee 200 amp Continuous Duty Solenoids • SPST • Normally open contacts • One circuit: Off-On INSULATED No. 24143 12 volt Rated at 200 amps. Contacts: silver. Housing: plated steel. Contact terminal: 5/16"-24 thread. Bracket mounting holes: 5/16" x 19/32", 2 13/64" on centers. No. 24144 24 volt Rated at 200 amps (carry only, not to break 200 amps at 24 VDC). Intermittent Duty Solenoids • SPST • Normally open contacts • One circuit: Off-On Contacts: copper. Housings: plated steel and phenolic. Terminals: copper; small ignition and ground terminals are 10-32 thread, large contact terminals are 5⁄16" - 24 thread, with hex nuts and lock washers included. Intermittent Duty • 120 amps make • 65 amps break • 10 secs. on - 30 min. off No. 24008 Steel Housing 24 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts BAT. 24 No. 24104 Steel Housing Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED INSULATED Intermittent Duty • 750 amps make • 100 amps break • 10 secs. on - 20 min. off No. 24037 Steel Housing 12 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts GROUNDED No. 24022 Phenolic Housing Bracket mounting holes 9/32" x 25/64", 2 7/64" on centers. For plasticized model see No. 24071 pg. 58. No. M-202 Steel Housing 12 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts MARINE CONSTRUCTION Clear dichromate protective finish. Brass hex nuts and lock washers. GROUNDED No. 24044 Steel Housing 12 Bracket mounting holes 5/16" x 19/32", 2 1/8" on centers. Volts O No. 24020 Phenolic Housing Bracket mounting holes 9/32" x 11/16", 2 1/8" on centers. GROUNDED Resistor Shorting Circuit 12 Volts No. 24103 Steel Housing No. 24021 Phenolic Housing Contact terminal 5/16"-24 thread, bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal 5/16"-24 thread, bracket mounting holes 9/32" x 1/2", 2 13/64" on centers. GROUNDED Resistor Shorting Circuit O No. 24138 Phenolic Housing Contact terminal 5/16"-18 thread, bracket mounting holes 9/32" x 11/16", 2 7/64" on centers. 12 Volts GROUNDED 54 With breather O Minimum order quantity may apply. Please consult factory or current price list. Solenoids Section E Intermittent Duty Solenoids • SPST • Normally open contacts • One circuit: Off-On Contacts: copper. Housings: plated steel and phenolic. Terminals: copper; small ignition and ground terminals are 10-32 thread, large contact terminals are 5⁄16" - 24 thread, with hex nuts and lock washers included. Intermittent Duty • 750 amps make • 100 amps break • 10 secs. on - 20 min. off 12 BAT. Volts No. 24046 Steel Housing No. 2430 Phenolic Housing Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Bracket mounting holes 9/32" x 1/2", 2 13/64" on centers. INSULATED For plasticized model see No. 24077 pg. 58. No. 24023 Phenolic Housing No. 24047 Steel Housing 12 Bracket mounting holes 9/32" x 3/4", 2 13/64" on centers. Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED For plasticized model see No. 24076 pg. 58. No. M-200 Steel Housing 12 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED 12 BAT. No. 24060 Steel Housing Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED Intermittent Rating: 750 amps make, 100 amps break 10 seconds On, 30 minutes off ARINE U ® 7 O ST E W D 7 0I T C ER SW LI P 12 M HB No. M-200-01 Steel Housing UL listed ISO 8846 MARINE Intermittent Duty • 750 amps make • 100 amps break • 10 secs. on - 20 min. off No. 24041 Steel Housing 6 Bracket mounting holes 5/16" x 19/32", 2 1/8" on centers. Volts 6 6 GROUNDED O No. 24055 Steel Housing Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED Bracket mounting holes 5/16" x 19/32", 2 1/8" on centers. Volts GROUNDED BAT. No. 24039 Steel Housing O No. 24043 Steel Housing 6 Bracket mounting holes 5/16" x 19/32", 2 1/8" on centers. Volts INSULATED O Minimum order quantity may apply. Please consult factory or current price list. 55 ® Cole Hersee Continuous Duty Solenoids • SPDT • Normally open and normally closed contacts For forward and reverse systems in golf carts, garden tractors, fork lift trucks, winch operation, etc. Housings: steel. Contact terminal: 5⁄16"-24 thread. Bracket mounting holes: 5⁄16" x 19⁄32", 2 13⁄64" on centers. Continuous Duty Normally closed contacts • 35 amps Normally open contacts • 85 amps 12 36 Volts Volts INSULATED No. 24400 INSULATED 24 No. 24401 For plasticized model see No. 24401-04 page 58. 12 Volts Volts INSULATED GROUNDED No. 24402 No. 24401-01 Continuous Duty Solenoid • SPST • Normally closed contacts Continuous Duty Normally closed contacts • 35 amps 12 Volts INSULATED No. 24420 Latching Solenoid Continuous Duty • For 12 VDC systems • Requires less than 3.5 amps to operate • Compact, mounts in tight locations. No heat is generated because coil is taken out of circuit. Electrical Rating 110 amps continuous (carry only). No. 24200 Case: plated steel. Terminals: small terminals 10-32 thread, large terminals 5/16"-24 thread, hex nuts and lockwashers included. Bracket mounting holes: .281" (7.16mm) x .310" (7.87mm), 2.20" (55.88mm) on centers. How it works: 1. Actuate a momentary switch to close the solenoid's contacts, allowing current to flow. 2. Once the momentary switch is actuated, the circuit remains closed. 3. A second actuation of the momentary switch re-opens the circuit. 56 Application Information Remotely operated battery isolator Can be used to isolate one battery from another in a two battery system and prevent battery power loss or drain. The No. 24200 will not produce voltage drop typically associated with battery isolators because of its electro-mechanical characteristics (i.e. not relying on diodes) to perform the isolating function. In this application, No. 24200 is used in conjunction with a momentary switch. Remote battery disconnect switch. Can be used as a battery disconnect switch where vehicle wiring constraints do not allow for the location of heavy gauge wires. In this application, No. 24200 is used in conjunction with a momentary switch located on a panel or dash. O Minimum order quantity may apply. Please consult factory or current price list. Solenoids Section E Continuous Duty Solenoids • SPST • Normally open contacts • One circuit: Off-On Contacts: copper. Housings: plated steel. Ignition and ground terminals: copper, 10-32 thread, hex nuts and lock washers included. Contact terminals: copper, 5⁄16" - 24 thread, hex nuts and lock washers included. Continuous Duty • 85 amps No. 24080 Steel Housing Volts INSULATED For plasticized model see No. 24135 pg. 58. Bracket mounting holes 9/32" x 11/16", 2 7/64" on centers. 36 Bracket mounting holes 9/32" x 11/16", 2 7/64" on centers. Volts M ARINE U ® 7 O ST E W D 7 0I T C ER SW LI P No. 24080-01 Steel Housing HB 36 UL listed ISO 8846 MARINE Continuous Rating: 65 amps 36 VDC Intermittent Rating: 120 amps make, 65 amps break 10 seconds On, 30 minutes off INSULATED Continuous Duty • 85 amps 24 24 24 Volts Volts Volts GROUNDED BAT. INSULATED INSULATED No. 24124 Steel Housing No. 24063 Steel Housing No. 24107 Steel Housing Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. For plasticized model see No. 24063-08 pg. 58. Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Continuous Duty • 85 amps No. 24106 Steel Housing 12 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts 12 BAT. Volts INSULATED Bracket mounting holes 5/16" x 19/32", 2 1/8" on centers. Volts GROUNDED 12 No. 24082 Steel Housing GROUNDED No. 24115 Steel Housing Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. No. 24059 Steel Housing 12 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED For plasticized model see No. 24117 pg. 58. Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED ARINE U ® HB 12 M LI P No. 24059-08 Steel Housing 7 O ST E W D 7 0I T C ER SW UL listed ISO 8846 MARINE Continuous Rating: 65 amps 12 VDC Intermittent Rating: 750 amps make, 100 amps break 10 seconds On, 30 minutes off Continuous Duty • 85 amps O No. 24105 Steel Housing 6 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers) Volts GROUNDED No. 24097 Steel Housing 6 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Volts INSULATED O Minimum order quantity may apply. Please consult factory or current price list. 57 Cole Hersee ® Plasticized Steel Housing Solenoids Intermittent Duty • SPST • Normally open contacts • One circuit: Off-On Intermittent Duty • 750 amps make • 100 amps break • 10 secs. on - 20 min. off 12 12 Volts BAT. 12 Volts INSULATED Volts GROUNDED INSULATED No. 24076 No. 24077 No. 24071 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. Continuous Duty • SPST• Normally open contacts • One circuit: Off-On Continuous Duty • 85 amps No. 24135 Volts INSULATED Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. M 36 No. 24135-01 7 O ST E W D 7 0I T C ER SW UL listed ISO 8846 MARINE M No. 24063-08 24 Volts INSULATED Continuous Rating: 65 amps 36 VDC Intermittent Rating: 120 amps make, 65 amps break 10 seconds On, 30 minutes off ARINE U ® 7 O ST E W D 7 0I T C ER SW LI P Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. ® HB INSULATED Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. U LI P Volts ARINE HB 36 UL listed ISO 8846 MARINE Continuous Rating: 65 amps 24 VDC Intermittent Rating: 120 amps make, 65 amps break 10 seconds On, 30 minutes off Continuous Duty • 85 amps No. 24117 12 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. Volts INSULATED M Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. Volts INSULATED U ® 7 O ST E W D 7 0I T C ER SW HB No. 24117-01 LI P 12 ARINE UL listed Continuous Rating: 65 amps 12 VDC Intermittent Rating: 750 amps make, 100 amps break ISO 8846 10 seconds On, MARINE 30 minutes off Continuous Duty • SPDT • Normally open and normally closed contacts Continuous Duty • normally closed contacts 35 amps • normally open contacts 85 amps 12 No. 24401-04 Bracket mounting holes 5/16" x 19/32", 2 13/64" on centers. Contact terminal: 5⁄16"-24 thread. Volts INSULATED 58