DETECTION AREA TOP VIEW 30 SIDE VIEW 25 20 15 10 0 5 0 DESCRIPTION: 5 10 21 30 this setting is used, the controlled lighting load will only turn on if the ambient light present is less than the desired setting. 20 There is a daylight sensor built into the sensor to allow for ambient light override functionality. If the ambient light level in the room is at a 9 15 Sensor designed to work with any power pack, to automatically control lighting in standard and cold weather applications. This sensor utilizes an industry leading 8-element Infrared Detector for superior minor motion detection while combining with a lens that provides major motion detection up to 2000 sq. ft. at a standard 9 ft. mounting height. The sensor operates in climates down to -40° Fahrenheit or Celsius. Dual Form C Relays are present on the sensor to allow for integration to NexLight’s 2-wire system and HVAC/BMS Systems. The sensor turns the lights on and keeps them on while occupancy is detected and will turn 14 0 14 21 (ft) 30 25 20 15 10 5 0 5 10 15 20 25 30 Field of view intersection with floor (Top view in feet 9 foot mounting height) SETTINGS: DETECTION AND ACTIVATION: When a person enters a room, the sensor detects major body motion and turns the light on. The light is kept on even as smaller body movement is detected. This sensor’s detection sequence logic (DSL) minimizes false triggering by continuously analyzes the motion detection signal and adjusts internal operation to maximize the A B and electrical noise. INSTALLATION: See the back of this installation manual for installation instructions. The sensor is fully operational after 30 seconds of powering up the device. OPERATION OF SENSOR Motion detection by the HDIR sensor will turn ON the lights as well as keep them ON. When motion is not detected, the lights will turn OFF after the delayed-OFF time. Delayed-OFF Time: The sensor is designed to turn the lights OFF if no black twist knob designated for timer inside the control console. Dependent upon environmental conditions and occupancy patterns, the adapting patterns will modify the delayed-OFF time to match the parameters of each installation. Walk-Through Mode: The walk-through feature is useful when a room is momentarily occupied, such as a storage room. When a person enters the room, the lights will turn on and stay on for 2.5 minutes. After 2.5 (Fig. Operation control console) All aspects of sensor operation can be adjusted here OPERATION MODE ADJUSTMENT Switch A1 A2 A3 A4 B1 B2 B3 B4 Function Bank A Not Used Not Used Not Used Walk-Thru / Normal Bank B Daylight Sensor LED Indicator Test Mode Not Used Off Settings Walk-Thru Enabled On Normal Occupancy Enabled Disabled Enabled Disabled Off-On-Off (Toggle Enter/Exit) TESTING THE SENSOR Scenario A: If motion is detected within 10 seconds of the lights shutting Test Mode: This mode is used to set the Delayed-OFF Time to 5 seconds for Scenario B: If no motion is detected within 10 seconds of the lights while in test mode. 1. Ensure Power is On 2. Remove the cover from the Operation Control Console it sees detection the lights will turn on for 2.5 minutes. Daylight Sensor: To enable daylight sensor operation, set Dip Switch 1 in Bank B to OFF. This puts the sensor in a stand-by mode when the natural light level exceeds the selected Foot Candles (FC) level inhibiting the lights from turning ON. LED Operation: The Sensor has two LED indicators that, when enabled, has been detected by Infrared Technology. Infrared Adjustment- For maximum range, set fully clockwise (CW). If reduced range is required, then turn counterclockwise (CCW) and test Delayed-OFF Time Adjustment: Each time motion is detected, the load remains activated for a pre-set time, which is set by the Delayed-OFF Time Adjustment, The fully CCW setting (30 seconds) can be used for testing. The fully clockwise setting is 30 Minutes. If motion is detected during the ON time, then the load remains activated until the full ON time has passed since the latest motion detection. Daylight Sensor Adjustment: This level needs to be set in a room where natural light is at the desired level for the lighting load to not be turned on. The sensor will still see motion (indicated by the red LEDS) 1. Set the daylight sensor knob to fully counter clockwise (lowest level) 3. Turn the daylight sensor knob clockwise until the light turns on. 5. This will be the setting defaulted to the OFF position. 4. To enter Test Mode, move the switch from OFF to ON and then back to OFF. IF B3 is already in the ON position, test mode can be entered by just moving it back to the OFF position. Infra re d R a nge Range setting Full CCW = min.(OFF) Full CW = max. Notes for Test Mode: 1. The Delayed-OFF Time will remain in the 5 second test mode for 15 minutes. It will then automatically reset to the Delayed -OFF Time setting Factory Default Daylight Sensor Delayed-OFF time test mode. 2. To manually take the sensor out of the test mode, move switch B3 from OFF to ON and back to OFF again. Full CCW = min.(30 sec.) Full CW = max.(30 min.) 30sec 5min 10min 20min 30min Factory Default Full CCW = Lights stay OFF Full CW = Lights always turn ON (NO daylight override) 20 FC 40 FC 80 FC 160 FC 320 FC Factory Default Included Parts List: Sensor (1) Wall Anchors (3) PIR detection Mask (1) Slotted/Phillips Screwdriver Pencil Hole Saw 1 INSTALLATION INSTRUCTIONS Base mounting ring (1) Spring mounting clip (2) 7/8” Wall anchor screw (3) Tools required for install: WARNINGS AND CAUTIONS: Wire Stripper Wire Cutters • To be installed and/or used in accordance with appropriate electrical codes and regulations. • If you are unsure about any part of these instructions, FCC COMPLIANCE STATEMENT: This device complies with part 15 and part 18 of the FCC rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 2 power at circuit breaker 3 Prepare and connect wires Select mounting location (For best results mount at least 6 feet away from air vents) • Sensors must be mounted on a vibration free surface. • All sensors must be mounted at least 6 feet away from air vents. • Do not mount sensors closer than 10 feet from each other. • Do not touch the surface of the PIR lens. Clean outer surface only. 4 Wiring to power pack (typical power pack shown wire color may vary) 1/2" (1.3 cm) Cut (if necessary) WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is before wiring! Use the included PIR Mask when sensor location may cause false ON’s due to Black Red (24V+) Strip wire Mask (measure bare wire here) Masking is not required in a corner mounting application. Insert wires into correct terminal blocks and tighten. Be sure to double check correct wiring connections! Black (24V-) Power Pack Hot (Black) Blue (CTL) Load Blue Blue NORMALLY CLOSED 5 Option A. Drop ceiling w/ mounting clips A. remove mounting ring B. install clips _ Line 120/277/347VAC 60Hz 24 Vdc 5 CONTROL NORMALLY CLOSED COMMON NORMALLY OPEN By masking sections, you can block hallway traffic COMMON NORMALLY OPEN + NORMALLY CLOSED Black COMMON White Option B. Junction box 1. Use two #8 32 screws (not supplied) to fasten the base ring to the ceiling. 3. Press the sensor onto the base ring. Octagon Box 4" x 1 1/2" deep 3.375 in D. mount sensor 5 Terminal Block Connections 1 1 Wallboard Ceiling NORMALLY CLOSED White Option C. Base ring w/ mounting anchors 1. cut 2” hole in ceiling 2 in 2. mount sensor Low-Voltage Wires Wallboard Ceiling Low Voltage Wires Mounting Clips COMMON Neutral (White) 2. Align the sensor’s two eyelets with the base ring’s two hooks. C. cut 3.375” hole in ceiling NORMALLY OPEN NORMALLY OPEN Low-Voltage Wires #8-32 Screws (not supplied) 2 Mounting Anchors Sensor Base Ring Mounting Screws (2 places) Sensor Base Sensor Front Cover LIMITED 5 YEAR WARRANTY AND EXCLUSIONS for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied