4 WIRE EDGE INTERFACE KIT WARNING WARNING MODEL 71-4WIREEDGE CAUTION 01-18186C To avoid SERIOUS personal INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual. This device is for use ONLY with LiftMaster Commercial Door Operators. Use on other than recommended equipment voids warranty and may cause property damage or SERIOUS personal INJURY. FIGURE 1 CPS3-01 Option Logic Board Insert Logic Board into any available slot Logic 3 Logic Board Shown FIGURE 2 4 Wire Edge Interface Board Terminal Block Terminal Block in LiteTouch Sensing Edge Control Unit 3 NCC 4 J I H G 5 NCC 6 F E D C ©2006 The Chamberlain Group, Inc All Rights Reserved. 24V 270K Ohm Resistor Operator Main Logic Board L3 Terminal Block 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Stop B A 1 2 Open WIRING INSTRUCTIONS FOR THE 4 WIRE EDGE INTERFACE BOARD TO A 4 WIRE SAFETY EDGE 1. Disconnect power to the operator. 2. Remove the jumper wire from terminals G and H on the 4 Wire Edge Interface Board. 3. Remove the jumper wire from terminals I and J on the 4 Wire Edge Interface Board. 4. Run wire pairs from the sensing edge to terminals G, H and I, J respectively. 5. Restore power to the operator. Verify the functionality of the edge. NOTE: Be sure to leave the 270k Ohm resistor between terminals A and B attached. WARNING Close WIRING INSTRUCTIONS FOR THE 4 WIRE EDGE INTERFACE BOARD TO A LITETOUCH SENSING EDGE SYSTEM 1. Door must be in full open or closed position. 2. Disconnect power to the operator. 3. Remove the jumper wire from terminals G, H, I and J on the 4 wire Edge Interface Board. 4. Insert 4 Wire Edge Interface Board into one of the two slots on the operator’s main logic board (Figure 1). 5. Run the 6 wire cable provided with the LiteTouch edge control unit and make the following connections: a) Connect the BROWN lead between 3 on the edge control and J on the 4 wire interface board. b) Connect the WHITE lead between 4 on the edge control and I on the 4 wire interface board. c) Connect the GREEN lead between 5 on the edge control and H on the 4 wire interface board. d) Connect the BLUE lead between 6 on the edge control and G on the 4 wire interface board. 6. To power the sensing edge control unit run the remaining leads of the cable as follows: a) Connect the BLACK lead between 1 on the edge control and terminal 13 on the motor operator terminal block. b) Connect the RED lead between 2 on the edge control and terminal 14 on the motor operator terminal block. NOTE: Use terminals 12 and 13 for Logic 2 operators. 7. Restore power to the operator. Verify the functionality of the edge. NOTE: Be sure to leave the 270k Ohm resistor between terminals A and B on the 4 wire edge interface card. This configuration is a continuous self monitoring system. Printed in Mexico