SOLID FUEL HEATING QUESTIONNAIRE PLEASE ATTACH PHOTOGRAPH Policy No: Insured: Agent/Broker: Address of premises where unit is installed, Principal residence or location of unit within the dwelling. HEATING UNIT Type (a) ڤFireplace (with doors) (e) ڤFactory manufactured oil/solid fuel combination unit (b) ڤPot belly, box, franklin or acorn stove (f) ڤOil furnace with add.on solid fuel burning unit (loose fitting doors or no doors) (c) ڤAirtight" stove (g) ڤOther, specify (d) ڤAirtight" insert in ڤSolid masonry fireplace "Airtight - tight fitting doors and seams ڤZero clearance fireplace Fuel ڤWood only ڤWood and oil ڤOther. specify Quantity of wood burned per year Stored where and how Make Labelled Model Age ڤCanadian Standards Association ڤUnderwriters' Laboratories of Canada ڤWarnock.Hersey Professional Service Ltd ڤNone or other, specify How often is the heating unit used during the heating season? Chimney Type hours per day days per week ڤMasonry - ڤBuilt from ground ڤBracket Chimney lining - ڤFlue tile ڤNone or other, specify ڤFactory built double walled metal chimney - manufacturer Labelled ڤCanadian Standards Association ڤUnderwriters' Laboratories of Canada ڤWarnock.Hersey Professional Service Ltd. ڤNone or other specify ڤOther type of chimney, specify ڤUnknown ڤSame as heating unit or Was the chimney designed for the type of fuel specified above? Does unit share a chimney flue with any other heating unit ڤno Chimney is installed ڤinside building ڤoutside building How often is the chimney cleaned ڤyes or identify fuel for which designed ڤyes, describe other unit overleaf and indicate which pipe enters Chimney above the other. Date of last cleaning (year. month) Installation: How many 90° bends are in the pipe? Was the heating unit installed by a heating contractor ڤunknown ڤno ڤyes, name of firm Was the chimney installed by a heating or masonry contractor ڤunknown ڤno ڤyes, name of firm Does the stovepipe pass through a concealed space or any wall, partition, floor or ceiling of combustible construction ڤyes ڤno Is protective shielding used around heating unit-if so, describe (material used, clearances, etc" ) Diagram (Please complete the following for hearing types (b), (c), and (g). If your unit does not fit diagram please attach your own.) 1. Construction of back wall 2. Shortest distance from unit to back wall ڤin ڤcm 3. Is there a thimble where the pipe passes through wall? ڤyes ڤno Total length or stovepipe ڤin ڤcm 4. Shortest distance from stovepipe to ceiling ڤin ڤcm 5. Is there a noncombustible pad? ڤyes ڤno 6. Construction of floor 7. Distance from unit to floor ڤin ڤcm 8. Distance from side of unit to end of pad ڤin ڤcm 9. Distance from front or unit to end of pad ڤin ڤcm 10. Construction or nearest side wall 11, Shortest distance from unit to nearest side wall ڤin ڤcm 12. Shortest distance from unit to 'furniture, fuel or other combustible material ڤin ڤcm Has the installation including chimney been inspected and approved by a fire department or building code inspector. Completed Date