May 2003 High Speed Fuses Typower Zilox IGBT Fuse 690Vac / 750Vdc IEC* 700Vac / 800Vdc ULà 25-350A Electrical Characteristics Type Rated current RMS-amp 2 000FU/70 2 I t [A s] Pre-arc 25 32 40 50 63 80 100 125 160 200 250 315 350 Watt Loss [W] 25 45 75 135 260 460 795 1.300 2.550 4.350 7.400 12.500 17.000 Ordering Information Curves Ref. No. Without indicator Data sheet 170M1750 170M1751 170M1752 170M1753 170M1754 170M1755 170M1756 170M1757 170M1758 170M1759 170M1760 170M1761 170M1762 170K6422-23 Clearing at 690V 135 240 395 695 1.350 2.350 4.000 6.800 13.500 22.000 37.500 65.000 88.000 12 13 14 16 17 20 25 29 34 40 48 60 65 - Interrupting rating 200kA RMS Symmetrical (Estimated) - Optimized for use in IGBT inverter circuits with DC-link voltages up to 800Vdc - Low inductance < 15 nH - Watt Loss provided at rated current * Tested at 863Vdc acc. to IEC 60269-4 à Tested at 800Vdc acc. to UL 248-1 (Pending) 170Q0501E 2003.05.01 MA For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk Typower Zilox IGBT Fuse 690Vac / 750Vdc IEC 700Vac / 800Vdc UL High Speed Fuses 25-350A Total clearing It2 The total clearing It2 at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, E,g (RMS). Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage E,g (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 1,5 3 2,5 1,0 1,0 2 1,8 1,6 1,4 1,2 0,6 0,5 0,8 0,7 0,4 3 0,5 10 0,3 8 0,4 7 6 0,3 0,2 5 0,15 0,2 4 200 300 400 500 600 700 3 200 300 400 500 600 700 0,1 30 40 50 60 70 80 90 100% Dimensions Dimensions in mm 1mm = 0,0394" 1" = 25,4mm For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk May 2003 High Speed Fuses Typower Zilox IGBT Fuse 690Vac / 750Vdc IEC* 700Vac / 800Vdc ULà 25-350A Electrical Characteristics Type Rated current RMS-amp 2 000FN/70 2 I t [A s] Pre-arc 25 32 40 50 63 80 100 125 160 200 250 315 350 Watt Loss [W] 25 45 75 135 260 460 795 1.300 2.550 4.350 7.400 12.500 17.000 Ordering Information Curves Ref. No. With indicator Data sheet 170M1730 170M1731 170M1732 170M1733 170M1734 170M1735 170M1736 170M1737 170M1738 170M1739 170M1740 170M1741 170M1742 170K6422-23 Clearing at 690V 135 240 395 695 1.350 2.350 4.000 6.800 13.500 22.000 37.500 65.000 88.000 12 13 14 16 17 20 25 29 34 40 48 60 65 - Interrupting rating 200kA RMS Symmetrical (Estimated) - Optimized for use in IGBT inverter circuits with DC-link voltages up to 800Vdc - Low inductance < 15 nH - Watt Loss provided at rated current * Tested at 863Vdc acc. to IEC 60269-4 à Tested at 800Vdc acc. to UL 248 -1 (Pending) 170Q0503E 2003.05.01 MA For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk Typower Zilox IGBT Fuse 690Vac / 750Vdc IEC High Speed Fuses 700Vac / 800Vdc UL 25-350A Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (RMS). Arc Voltage This curve gives the peak arc voltage, UL , which may appear across the fuse during its operation as a function of the applied working voltage Eg, (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp , is given as a function of the RMS load current, Ib , in % of the rated current. 1,5 3 2,5 1,0 1,0 2 1,8 1,6 1,4 1,2 0,6 0,5 0,4 3 0,5 10 0,4 8 7 6 0,3 0,8 0,7 0,3 0,2 5 0,15 0,2 4 200 300 400 500 600 700 3 200 300 400 500 600 700 0,1 30 40 50 60 70 80 90 100% Dimensions Dimensions in mm 1mm = 0,0394" 1" = 25,4mm For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk May 2003 High Speed Fuses Typower Zilox IGBT Fuse 690Vac / 750Vdc IEC* 700Vac / 800Vdc ULà 100-630A Electrical Characteristics Type Rated current RMS-amp 2 2 I t [A s] Pre-arc 230FU/70 Ordering Information Watt Loss [W] 100 125 160 200 250 315 350 400 450 500 550 630 380 645 1.350 2.550 4.950 9.350 12.000 18.500 27.000 37.500 48.500 69.500 Ref. No. Without indicator Curves Data sheet Clearing at 690V 1.950 3.300 7.000 13.500 25.000 47.500 61.000 94.500 140.000 190.000 245.000 355.000 35 42 47 54 62 72 78 80 85 90 95 105 170M1770 170M1771 170M1772 170M1773 170M1774 170M1775 170M1776 170M1777 170M1778 170M1779 170M1780 170M1781 170K6426-27 - Interrupting rating 200kA RMS Symmetrical (Estimated) - Optimized for use in IGBT inverter circuits with DC-link voltages up to 800Vdc - Low inductance < 15 nH - Watt Loss provided at rated current * Tested at 863Vdc acc. to IEC 60269-4 à Tested at 800Vdc acc. to UL 248-1 170Q0502E 2003.05.01 MA For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk Typower Zilox IGBT Fuse 690Vac / 750Vdc IEC 700Vac / 800Vdc UL High Speed Fuses 100-630A Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (RMS). Arc Voltage This curve gives the peak arc voltage, UL , which may appear across the fuse during its operation as a function of the applied working voltage Eg, (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp , is given as a function of the RMS load current, Ib , in % of the rated current. 1,5 3 2,5 1,0 1,0 2 1,8 1,6 1,4 1,2 0,6 0,5 0,4 3 0,5 10 0,4 8 7 6 0,3 0,8 0,7 0,3 0,2 5 0,15 0,2 4 200 300 400 500 600 700 3 200 300 400 500 600 700 0,1 30 40 50 60 70 80 90 100% Dimensions Dimensions in mm 1mm = 0,0394" 1" = 25,4mm For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk May 2003 High Speed Fuses Typower Zilox IGBT Fuse 690Vac / 750Vdc IEC* 700Vac / 800Vdc ULà 100-630A Electrical Characteristics Type Rated current RMS-amp 2 2 I t [A s] Pre-arc 230FN/70 Watt Loss [W] 100 125 160 200 250 315 350 400 450 500 550 630 380 645 1.350 2.550 4.950 9.350 12.000 18.500 27.000 37.500 48.500 69.500 Ordering Information Curves Ref. No. With indicator Data sheet Clearing at 690V 1.950 3.300 7.000 13.500 25.000 47.500 61.000 94.500 140.000 190.000 245.000 355.000 35 42 47 54 62 72 78 80 85 90 95 105 170M1785 170M1786 170M1787 170M1788 170M1789 170M1790 170M1791 170M1792 170M1793 170M1794 170M1795 170M1796 170K6426-27 - Interrupting rating 200kA RMS Symmetrical (Estimated) - Optimized for use in IGBT inverter circuits with DC-link voltages up to 800Vdc - Low inductance < 15 nH - Watt Loss provided at rated current * Tested at 863Vdc acc. to IEC 60269-4 à Tested at 800Vdc acc. to UL 248-1 170Q0504E 2003.05.01 MA For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk Typower Zilox IGBT Fuse 690Vac / 750Vdc IEC 700Vac / 800Vdc UL High Speed Fuses 100-630A Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (RMS). Arc Voltage This curve gives the peak arc voltage, UL , which may appear across the fuse during its operation as a function of the applied working voltage Eg, (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp , is given as a function of the RMS load current, Ib , in % of the rated current. 1,5 3 2,5 1,0 1,0 2 1,8 1,6 1,4 1,2 0,6 0,5 0,4 3 0,5 10 0,4 8 7 6 0,3 0,8 0,7 0,3 0,2 5 0,15 0,2 4 200 300 400 500 600 700 3 200 300 400 500 600 700 0,1 30 40 50 60 70 80 90 100% Dimensions Dimensions in mm 1mm = 0,0394" 1" = 25,4mm For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk May 2003 Typower Zilox IGBT Fuse 1000Vac / 1000Vdc* 25-250A Electrical Characteristics Type Rated current RMS-amp 2 000FU/90 2 I t [A s] Pre-arc 25 32 40 50 63 80 100 125 160 200 225 250 Watt Loss [W] 19 34 61 135 245 505 1.050 1.900 4.050 8.500 12.000 16.000 High Speed Fuses Ordering Information Curves Ref. No. Without indicator Data sheet 170M1802 170M1803 170M1804 170M1805 170M1806 170M1807 170M1808 170M1809 170M1810 170M1811 170M1812 170M1813 170K6680-81 Clearing at 1000V 95 170 300 675 1.200 2.500 5.150 9.500 20.000 42.000 59.000 79.500 14 17 20 21 22 27 32 34 37 43 45 48 - Interrupting rating 200kA RMS Symmetrical (Estimated) - Watt Loss provided at rated current - Optimized for use in IGBT inverter circuits with DC-link voltages up to 1000Vdc . - Low inductance < 20 nH - UL dc recognized * Tested at 1150Vdc acc. to IEC 60269-4 Tested at 1000Vdc acc. to UL 248-1 170Q0507E 2003.05.01 MA For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk Typower Zilox IGBT Fuse High Speed Fuses 25-250A 1000Vac / 1000Vdc Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (RMS). Arc Voltage This curve gives the peak arc voltage, UL , which may appear across the fuse during its operation as a function of the applied working voltage Eg, (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp , is given as a function of the RMS load current, Ib , in % of the rated current. 1,5 3 2,5 1,0 1,0 2 1,8 1,6 1,4 1,2 0,6 0,5 0,4 3 0,5 10 0,4 8 7 6 0,3 0,8 0,7 0,3 0,2 5 0,15 0,2 4 500 600 700 800 900 1000 3 500 600 700 800 900 1000 0,1 30 40 50 60 70 80 90 100% Dimensions Dimensions in mm 1mm = 0,0394" 1" = 25,4mm For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk May 2003 Typower Zilox IGBT Fuse 1000Vac / 1000Vdc* 25-250A Electrical Characteristics Type Rated current RMS-amp 2 000FN/90 2 I t [A s] Pre-arc 25 32 40 50 63 80 100 125 160 200 225 250 Watt Loss [W] 19 34 61 135 245 505 1.050 1.900 4.050 8.500 12.000 16.000 High Speed Fuses Ordering Information Curves Ref. No. With indicator Data sheet 170M1842 170M1843 170M1844 170M1845 170M1846 170M1847 170M1848 170M1849 170M1850 170M1851 170M1852 170M1853 170K6680-81 Clearing at 1000V 95 170 300 675 1.200 2.500 5.150 9.500 20.000 42.000 59.000 79.500 14 17 20 21 22 27 32 34 37 43 45 48 - Interrupting rating 200kA RMS Symmetrical (Estimated) - Watt Loss provided at rated current - Optimized for use in IGBT inverter circuits with DC-link voltages up to 1000Vdc . - Low inductance < 20 nH - UL dc recognized * Tested at 1150Vdc acc. to IEC 60269-4 Tested at 1000Vdc acc. to UL 248-1 170Q0508E 2003.05.01 MA For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk Typower Zilox IGBT Fuse High Speed Fuses 25-250A 1000Vac / 1000Vdc Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (RMS). Arc Voltage This curve gives the peak arc voltage, UL , which may appear across the fuse during its operation as a function of the applied working voltage Eg, (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp , is given as a function of the RMS load current, Ib , in % of the rated current. 1,5 3 2,5 1,0 1,0 2 1,8 1,6 1,4 1,2 0,6 0,5 0,4 3 0,5 10 0,4 8 7 6 0,3 0,8 0,7 0,3 0,2 5 0,15 0,2 4 500 600 700 800 900 1000 3 500 600 700 800 900 1000 0,1 30 40 50 60 70 80 90 100% Dimensions Dimensions in mm 1mm = 0,0394" 1" = 25,4mm For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk May 2003 Typower Zilox IGBT Fuse 1000Vac / 1000Vdc* 100-500A Electrical Characteristics Type Rated current RMS-amp I2t [A2s] Pre-arc 230FU/90 100 125 160 200 250 315 350 400 450 500 Watt Loss [W] 600 1.200 2.550 4.650 9.300 18.500 24.500 37.500 52.000 69.500 High Speed Fuses Ordering Information Curves Ref. No. Without indicator Data sheet Clearing at 1000V 3.050 6.050 13.000 23.000 45.500 91.500 125.000 185.000 260.000 340.000 38 42 48 55 62 68 75 80 85 90 170M1824 170M1825 170M1826 170M1827 170M1828 170M1829 170M1830 170M1831 170M1832 170M1833 170K6682-83 - Interrupting rating 200kA RMS Symmetrical (Estimated) - Watt Loss provided at rated current - Optimized for use in IGBT inverter circuits with DC-link voltages up to 1000Vdc . - Low inductance < 20 nH * Tested at 1150Vdc acc. to IEC 60269-4 Tested at 1000Vdc acc. to UL 248-1 170Q0505E 2003.05.01 MA For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk Typower Zilox IGBT Fuse High Speed Fuses 100-500A 1000Vac / 1000Vdc Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (RMS). Arc Voltage This curve gives the peak arc voltage, UL , which may appear across the fuse during its operation as a function of the applied working voltage Eg, (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp , is given as a function of the RMS load current, Ib , in % of the rated current. 1,5 3 2,5 1,0 1,0 2 1,8 1,6 1,4 1,2 0,6 0,5 0,4 3 0,5 10 0,4 8 7 6 0,3 0,8 0,7 0,3 0,2 5 0,15 0,2 4 500 600 700 800 900 1000 3 500 600 700 800 900 1000 0,1 30 40 50 60 70 80 90 100% Dimensions Dimensions in mm 1mm = 0,0394" 1" = 25,4mm For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk May 2003 Typower Zilox IGBT Fuse 1000Vac / 1000Vdc* 100-500A Electrical Characteristics Type Rated current RMS-amp I2t [A2s] Pre-arc 230FN/90 100 125 160 200 250 315 350 400 450 500 Watt Loss [W] 600 1.200 2.550 4.650 9.300 18.500 24.500 37.500 52.000 69.500 High Speed Fuses Ordering Information Curves Ref. No. With indicator Data sheet Clearing at 1000V 3.050 6.050 13.000 23.000 45.500 91.500 125.000 185.000 260.000 340.000 38 42 48 55 62 68 75 80 85 90 170M1860 170M1861 170M1862 170M1863 170M1864 170M1865 170M1866 170M1867 170M1868 170M1869 170K6682-83 - Interrupting rating 200kA RMS Symmetrical (Estimated) - Watt Loss provided at rated current - Optimized for use in IGBT inverter circuits with DC-link voltages up to 1000Vdc . - Low inductance < 20 nH - UL recognized * Tested at 1150Vdc acc. to IEC 60269-4 Tested at 1000Vdc acc. to UL 248-1 170Q0506E 2003.05.01 MA For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk Typower Zilox IGBT Fuse High Speed Fuses 100-500A 1000Vac / 1000Vdc Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (RMS). Arc Voltage This curve gives the peak arc voltage, UL , which may appear across the fuse during its operation as a function of the applied working voltage Eg, (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp , is given as a function of the RMS load current, Ib , in % of the rated current. 1,5 3 2,5 1,0 1,0 2 1,8 1,6 1,4 1,2 0,6 0,5 0,4 3 0,5 10 0,4 8 7 6 0,3 0,8 0,7 0,3 0,2 5 0,15 0,2 4 500 600 700 800 900 1000 3 500 600 700 800 900 1000 0,1 30 40 50 60 70 80 90 100% Dimensions Dimensions in mm 1mm = 0,0394" 1" = 25,4mm For complete specification data, please contact Cooper Bussmann on bussmann@bussmann.dk