Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers Overview Overview Company Information Terminal Blocks Power Distribution Blocks Features Fuji Molded Case Circuit Breakers are more compact (especially 100A, 125A, 250A frames) than any breakers on the market, so they take up less space in control panels. This product group maintains conformity to all Worldwide standards. Agency Approvals • UL listed, MCCB, File: E90584 • UL listed, Accessories, File E93289 • CE marked • CCC marked • TUV certified Standards • UL 489 • CSA C22.2 No.5 • IEC 60947-2 • EN 60947-2 • GB 14048.2 • JIS C8201-2-1, 2 (ANN.1, 2) • Thermal-magnetic 15A through 800A • Suitable for branch circuit protection • Rated current of 15 to 800A, max 600V • Standard type and high-interrupting capacities available in identically sized breakers • Shunt Trip, Undervoltage Release and other accessories available • Line and load lug terminals included on all MCCBs • Auxiliary switch, Alarm switch and Shunt Trip can be installed in the field • Door-mounted or flange-mounted, flex shaft operating handles • All frame sizes suitable for reverse-feed applications • All breakers include mounting hardware • Terminal covers included for BW125 and BW250 frames. Terminal covers available for BW400, BW630 and BW800 frames. Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Fuji Electric Molded Case Circuit Breakers Technical Specifications Circuit Ampere Rating No. Breaker Type at 40°C Poles BW125JAGU BW250JAGU BW400SAGU BW630RAGU BW800RAGU Volts AC DC Type of Trip* Tools UL 489 Interrupting Ratings (rms Symmetrical Amperes) (kA) Volts AC (50/60 Hz) Volts DC 240 480 600 250** 15-125 3 600 250 N.I.T.U 50 30 10 10 125-250 3 600 250 N.I.T.U 50 30 10 10 250-400 3 480 250 N.I.T.U 50 35 – 10 500-600 3 480 250 N.I.T.U 100 50 – 10 700-800 3 480 250 N.I.T.U 100 50 – 10 Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear *Note: N.I.T.U denotes non-interchangeable trip unit. **Note: For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker Terms and Conditions Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-7 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – 125A Frame Fuji BW125A series MCCBs are 125 amp frame, 3-pole, non-adjustable magnetic trip, molded case circuit breakers (MCCB). The BW125 series is suitable for reverse feed applications. Included with each MCCB are Line and Load-side lug terminals, terminal covers and mounting hardware. Accessories are not pre-installed and are sold separately. BW125JAGU-3P125SB shown BW125-Frame Series Three-Pole Molded Case Circuit Breakers Rated Interrupting Capacity (kA) Part Number Rated UL489 CAN/CSA IEC60947-2, JIS C GB14048.2 Price Frequency Current C22.2 No. 5 8201-2-1 Icu/Ics Icu/Ics Ampere Voltage Interrupt Voltage Interrupt Voltage Interrupt Rating Capacity Capacity Capacity BW125JAGU-3P015SB $182.00 BW125JAGU-3P020SB $182.00 15 BW125JAGU-3P030SB BW125JAGU-3P040SB BW125JAGU-3P050SB BW125JAGU-3P060SB BW125JAGU-3P070SB BW125JAGU-3P075SB BW125JAGU-3P080SB BW125JAGU-3P090SB BW125JAGU-3P100SB BW125JAGU-3P125SB $182.00 30 $182.00 40 $182.00 50 $182.00 $182.00 20 50/60 Hz 60 70 $182.00 75 $182.00 80 $182.00 90 $182.00 100 $182.00 125 600V/Y AC 480V/i AC 480V/Y AC 240V AC 250V DC 10 kA 30 kA 30 kA 50 kA 10 kA 500V AC 440V AC 400V AC 380V AC 240V AC 250V DC 15/8 kA 30/15 kA 30/15 kA 30/15 kA 50/25 kA 15/8 kA 400V AC 230V AC 30/15 kA 50/25 kA Note: SCCR = UL489 interrupting capacity BW125-Frame Accessory Selection Guide Part Number BW9W1SG0 BW9FRG0 BW9FAG0 BW9RGAR BW9RGAT Price Description $24.00 Field installable auxiliary contact switch, use with BW125 and BW250 series MCCBs. SPDT. 20AWG lead wires, 19.69” long, left side mount only $49.50 Field installable DC shunt trip, use with BW125 and BW250 series MCCBs; 24 VDC/AC, 20 AWG lead wires 19.69” long, left and right side mount $49.50 Field installable AC shunt trip, use with BW125 and BW250 series MCCBs; 100-120 VAC, 20 AWG lead wires 19.69” long, left and right side mount $49.50 Field installable DC undervoltage release, use with BW125and BW250 series MCCBs; 24 VDC, 20AWG lead wires, 19.69” long, left side mount only Field installable AC undervoltage release, use with BW125and BW250 series MCCBs; 110-130 VAC, 20AWG lead wires, 19.69” long, left side $49.50 mount only $50.50 Replacement lugs for BW125-frame MCCBs,. package of 3 BW9SL0CA-3 $45.00 NEMA 12 rotary handle for BW125-Frame. Position indicating; lock-off feature. Shaft length: 0.39” BW9V0CA $11.00 NEMA 12 rotary handle shaft for BW9V0CA and BW9V0GA, BW125 and BW250 Frames. Steel shaft length: 6.06” (154 mm) BW9VSG0 $29.00 NEMA 12 rotary handle shaft for BW9V0CA and BW9V0GA, BW125 and BW250 Frames. Steel shaft length: 24” (610 mm) BW9VSG0-24 BW9F0CA-15A $237.00 NEMA 12 flexible shaft handle for BW125-Frame. Flange mounted. Lockable. Flex cable shaft length: 4.92’ (1.5m) BW9F0CA-20A $247.00 NEMA 12 flexible shaft handle for BW125-Frame. Flange mounted. Lockable. Flex cable shaft length: 6.56’ (2m) $12.00 Lockout attachment, use to lock out BW125 and BW250 series MCCBs. Lock not included. BW9Q1CA Note: Short-type terminal covers (gray-white) are supplied as standard. BW9V0CA BW9F0CA-15A BW9FAG0 BW9RGAR BW9Q1CA Book 3 (14.3) eCP-8 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – 125A● Frame Characteristic Curves Company Information Terminal Blocks Power Distribution Blocks (Rated current: 15A) 15A BW125BW125 Rated Current Wiring Accessories Minute 180 120 60 40 ZIPLink Connection System 20 Multi-wire Connectors 10 6 4 2 Sensor Cables and Connectors Max. value 1 40 M12 Junction Blocks 20 Operating time Max. total fault clearing time Min. value 2 Cable Ties Wire 150 Rated current correction ratio (%) Second Wiring Duct Reference temp. 40˚C 1 0.6 0.4 0.2 Instantaneous tripping characteristic 500A±100A 0.1 0.06 0.04 0.02 0.01 ● Panel Interface Connectors 10 6 4 1 1.5 2 Bulk Multi-conductor Cables 100 Wire Management Products Power Supplies 50 10 3 4 5 6 78 10 15 20 30 405060 80100 Multiple of rated current 0 10 20 30 40 50 DC Converters Ambient temp. (˚C) Transformers and Filters BW125 (Rated current: 20A) BW125 Rated Current 20A Circuit Protection Minute 180 120 60 40 Tools Test Equipment 20 Enclosures 10 6 4 Enclosure Climate Control 2 Max. value 1 40 Safety: Electrical Components 10 6 4 2 Min. value Max. total fault clearing time 1 0.6 0.4 0.2 0.1 0.06 0.04 0.02 0.01 Safety: Protective Wear Reference temp. 40˚C Instantaneous tripping characteristic 500A±100A 1 1.5 2 150 Rated current correction ratio (%) Second Operating time 20 Terms and Conditions 100 50 10 0 10 20 30 40 50 Ambient temp. (˚C) 3 4 5 6 7 8 10 15 20 30 40 506080100 Multiple of rated current Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-9 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – 125A Frame Characteristic Curves BW125current: Rated Current 30A BW125 (Rated 30A) Minute 180 120 60 40 20 10 6 4 2 Max. value 1 40 20 Min. value 2 Second Max. total fault clearing time Reference temp. 40˚C 1 0.6 0.4 150 0.2 Instantaneous tripping characteristic 500A±100A 0.1 0.06 0.04 0.02 0.01 Rated current correction ratio (%) Operating time 10 6 4 1 1.5 2 100 50 3 4 5 6 7 8 10 15 20 30 40506080100 Multiple of rated current 10 0 10 20 30 40 50 Ambient temp. (˚C) BW125current: Rated Current 40A BW125 (Rated 40A) Minute 180 120 60 40 20 10 6 4 Max. value 2 1 40 10 6 4 Min. value 2 Max. total fault clearing time 1 0.6 0.4 Reference temp. 40˚C 150 0.2 Instantaneous tripping characteristic 500A±100A 0.1 0.06 0.04 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40506080100 Multiple of rated current Rated current correction ratio (%) Second Operating time 20 100 50 10 0 10 20 30 40 50 Ambient temp. (˚C) Book 3 (14.3) eCP-10 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – 125A FrameCharacteristic Curves Company Information Terminal Blocks Power Distribution Blocks BW125, EW125 (Rated current: 50 - 125A) BW125 Wiring Accessories Current Range 50 -125A ZIPLink Connection System Minute 180 120 60 40 Multi-wire Connectors 20 10 6 4 Sensor Cables and Connectors M12 Junction Blocks Max. value 2 Panel Interface Connectors 20 Wiring Duct 10 6 4 Min. value 2 Cable Ties Wire 1 0.6 0.4 Reference temp. 40°C 150 Instantaneous tripping characteristic 10 In±20% 0.2 0.1 0.06 0.04 0.02 0.01 Max. total fault clearing time Rated current correction ratio (%) Second Operating time 1 40 1.5 2 3 4 5 6 78 10 15 20 30 40 50 60 80 100 Multiple of rated current Wire Management Products 100 Power Supplies 50 1 Bulk Multi-conductor Cables 10 0 10 20 30 40 Ambient temp. (°C) DC Converters 50 Transformers and Filters Note: Instantaneous tripping = 10 x (rated current) ± 20% In = rated current Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-11 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Dimensions Dimensions Units: mm [inches] 15 to 125A BW125A Frame 125 to 250A BW250A Frame Book 3 (14.3) eCP-20 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Products And Accessory Compatibility Match the Accessories with Fuji Molded Case Circuit Breakers Part Number BW9W1SG0 BW9W1SHA Description BW9FRG0 BW9FHA-R X X X X BW9FHA-A Shunt Trip 24 VAC/VDC (Mounting both Left and Right sides) Shunt Trip 24-48 VAC/VDC (Mounting Left side ONLY) Shunt Trip 100-120 VAC, 100-110 VDC (Mounting both Left and Right sides) Shunt Trip 100-280 VAC, 100-220 VDC (Mounting Left side ONLY) BW9RGAR BW9RHA-R BW9RGAT BW9RHA-1 UnderVoltage Release 24VDC (Left side ONLY) UnderVoltage Release 24 VAC/VDC (Left side ONLY) UnderVoltage Release 110-130 VAC (Left side ONLY) UnderVoltage Release 120-130 VAC, 125VDC (Left side ONLY) X X X X BW9SL0CA-3 BW9SL0GA-3 BW9SL1GA-3 Replacement Lugs Kit for 125 Amp frame Replacement Lugs Kit for 250 Amp frame up to 175A Replacement Lugs Kit for 250 Amp frame 200A to 250A X BW9V0CA BW9V0GA BW9VSG0 BW9VSG0-24 BW9V0HA BW9V0JA BZ-VS2 BZ-VS2-24 Rotary Handle Rotary Handle Optional Shaft for BW9V0CA and BW9V0GA, 6.063” Optional Shaft for BW9V0CA and BW9V0GA, 24” Rotary Handle, Rotary Handle, Optional Shaft for BW9V0HA and BW9V0JA, 3.48” Optional Shaft for BW9V0HA and BW9V0JA, H = 24” X BW9FAG0 BW125JAGU BW250JAGU BW400SAGU BW630RAGU BW800RAGU Auxiliary Switch (Mounting Left and right side) Auxiliary Switch (Mounting Left side ONLY) X BW9F0GA-20A BW9F0HA-15A BW9F0HA-20A BW9F0JA-15A BW9F0JA-20A X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Flange Handle (flex shaft), NEMA 12, 59“ (1.5m) cable, 250 Amp frame Flange Handle (flex shaft), NEMA 12, 78.7” (2.0m) cable, 250 Amp frame Flange Handle (flex shaft), NEMA 12, 59“ (1.5m) cable, 400 Amp frame Flange Handle (flex shaft), NEMA 12, 78.7” (2.0m) cable, 400 Amp frame Nema 12 flexible shaft handle for 630A or 800A frame. 59.06” (1.5m) cable Nema 12 flexible shaft handle for 630A or 800A frame. 78.74” (2m) cable X X X X BW9BTHA-L3W Terminal Cover for the 400A frame BW9BTJA-L3W Terminal Cover for the 630A AND 800A frame BW9Q1CA BW9QNHA X X X Handle (flex shaft), NEMA 12, 59“ (1.5m) cable, BW9F0CA-15A Flange 125 Amp frame Handle (flex shaft), NEMA 12, 78.7” (2.0m) cable, BW9F0CA-20A Flange 125 Amp frame BW9F0GA-15A X X Lockout Attachment 125A and 250A frames Lockout Attachment 400A, 630A and 800A frames X X X Internal Accessory Combinations for BW Series Available configurations 3-pole Right Left Undervoltage trip Shunt trip Auxiliary switch Handle MCCB Pole BW125 BW250 3 BW400 BW630 BW800 3 Auxiliary switch SPDT Shunt trip Undervoltage trip Auxiliary Switch + Shunt Trip Undervoltage + Auxiliary Switch Book 3 (14.3) eCP-24 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Wire Range Specifications Company Information Terminal Blocks Power Distribution Blocks Wiring Wiring Accessories • When connecting the wires, follow NEC (National Electric Code, USA) or CEC (Canadian Electrical code Part 1, Canada) instructions. • Adhere to the allowable number of strands of wire indicated in the table on the left. •Two wires cannot be connected together to a single connecting hole of lug terminal except BW400SAGU-3P400SB. •Follow the number of strands of wire indicated on the table. (Wire size and number of wire strands not listed on table can not be connected) •Do not solder the end of the wire. • Use copper wire rated for 75°C for connecting. UL or CSA approved wire is recommended. • Tighten the wire connections adequately, as a very large electromagnetic force will be generated when short circuit current is generated. • Perform additional tightening of the terminal screws periodically. 7 19 37 Rated current 15A to 350A Rated current 400A 3/0 AWG x 2 19 strands each Rated current 500A to 700A Rated current 800A 300 MCM x 3 37 strands each BW250 BW400 BW630 BW800 M12 Junction Blocks Rated Current (A) Tightening Torque Wire Size AWG or MCM (mm2) Lug Terminal* 15 14 AWG (2.1mm2) 20 12 AWG (3.3mm ) 30 10 AWG (5.3mm2) 40 8 AWG (8.4mm2) 50 8 AWG (8.4mm2) 60 6 AWG (13.3mm2) 70 4 AWG (21.1mm2) 75 4 AWG (21.1mm2) 80 4 AWG (21.1mm2) 90 3 AWG (26.7mm2) 100 3 AWG (26.7mm2) 125 1 AWG (42.4mm2) 125 1 AWG (42.4mm2) 150 1/0 AWG (53.5mm2) 175 2/0 AWG (67.4mm2) 200 3/0 AWG (85.0mm2) 225 4/0 AWG (107.2mm2) 250 250 MCM (127mm2) 250 250 MCM (127mm2) 300 350 MCM (177mm2) 350 500 MCM (253mm2) 400 3/0 AWGx2 (85.0mm2x2) 282 lb-in (31.9 N-m) 500 250 MCMx2 600 350 MCMx2 275 lb.-in. (31.07 N-m) 700 500 MCMx2 800 300 MCMx3 Wire Wire Management Products Power Supplies 2 DC Converters Transformers and Filters Circuit Protection 51 lb.-in. (5.8 N-m) Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components 204 lb.-in. (23 N-m) Safety: Protective Wear Terms and Conditions 385 lb.-in (43.5 N-m) 275 lb.-in. (31.07 N-m) *Lug terminals are supplied as standard. Note: Terminals are factory-installed only for BW400, BW630 and BW800 series. No replacement terminals available. Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Cable Ties Bulk Multi-conductor Cables Maximum Wire Sizes and Tightening Torque BW125 Sensor Cables and Connectors Wiring Duct Wire Size AWG or MCM (mm2) Number of Wire Strands Type Multi-wire Connectors Panel Interface Connectors Allowable Wire Specifications for Lug Terminals 14 to 2 (2.1 to 33.6) 1 to 4/0 (42.4 to 107.2) 250 to 500 (127 to 250) ZIPLink Connection System Circuit Protection eCP-33 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Field-mountable Accessories Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Defeatable Rotary Handle Operating Mechanisms Multi-wire Connectors BW9V0CA shown Sensor Cables and Connectors Rotary Operating Handles for Fuji MCCBs – Selection Guide V-type Handle Breaker V-type Type Handle Price BW125 BW9V0CA $45.00 BW250 BW9V0GA $45.00 Dimensions Units: inches [mm] H: inch(mm) 4.134±0.078 (105±2) With the optional shaft (x= 6.102 (155)) M12 Junction Blocks With the optional shaft (x= 24.567 (624)) V-type Mounting Handle Max. Mounting Range in which the Max. Mounting Range in which Screw Mass Depth hinge with H can Depth the hinge with H lb. (kg) H: inch(mm) be installed H: inch(mm) can be installed 9.843±0.078 (250±2) 5.512 to 9.843 (140 to 250) 28.307±0.078 (719±2) 28.307 - 5.591 (124 - 719) M4 x 3.35 (85) 1.48 (0.67) DC Converters Panel Door panel cutting 2.677 (68) MCCB 4-0.591 dia (ø15) MCCB handle C/L Transformers and Filters Handle C/L MCCB Handle C/L 43 3.5 dia Circuit Protection 0) Tools 3.071 (78) 4.449 (113) 4.449 (113) Wire Management Products Power Supplies • BW9V0CA, BW9V0GA (BW9VSG0, BW9VSG0-24: optional shafts) (ø9 Test Equipment 3.071(78) Load Panel thickness: 0.047 to 0.126 (1.2 to 3.2) C L Cable Ties Bulk Multi-conductor Cables 125A, 250A Frame V type handle C L Wiring Duct Wire Notes: • Handle is an operating mechanism only; not for sealing enclosure door. • Not available for side mounting • For BW250 Series only: When mounting a terminal cover, cut away part of it because it hides the mounting screws for the breaker. Remove the shaded parts in the figure . Line Panel Interface Connectors 2.559 (65) H Enclosures Note: Align the center of the hole cut in the panel with the center of the breaker handle. Enclosure Climate Control 28.87 (733.4) 1.929 (49) Safety: Electrical Components Handle C/L Padlock size 0.157 dia to 0.315 dia (ø4 to ø8) 4P 3P Safety: Protective Wear .94 (24.0) 2P Terms and Conditions Door hinge installation area C/L 0.039 (1) 0.315 (8) 1.929 (49) 1.181 (30) 4.724 (120) 2.362 (60) 1.614 (41) 2.362 (60) 0.591 (15) X 1.063 (27) Optional shafts BW9VSG0 X = 6.102 (155) BW9VSG0-24 X = 24.567 (624) 1.063 (27) 4.724 (120) Install the door hinge in the shaded area. BW9VSG0-24 optional shaft Breaker and Shaft Assembly Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-25 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Field-mountable Accessories Company Information Terminal Blocks Power Distribution Blocks Defeatable Flexible Handle Operating Mechanisms Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire BW9F0JA-20A shown Bulk Multi-conductor Cables Flex Shaft Handles for Fuji MCCBs – Selection Guide Breaker Type Handle Type BW9F0CA-15A BW9F0CA-20A BW9F0GA-15A BW250 BW9F0GA-20A BW9F0HA-15A BW400* BW9F0HA-20A BW630*& BW9F0JA-15A BW800* BW9F0JA-20A BW125 Price Description Wire Management Products $237.00 Nema 12 flexible shaft handle for 125A frame. 59.06” (1.5m)cable Power Supplies $247.00 Nema 12 flexible shaft handle for 125A frame. 78.74” (2m) cable $247.00 Nema 12 flexible shaft handle for 250A frame. 59.06” (1.5m)cable $257.00 Nema 12 flexible shaft handle for 250A frame. 78.74” (2m) cable $359.00 Nema 12 flexible shaft handle for 400A frame. 59.06” (1.5m)cable $369.00 Nema 12 flexible shaft handle for 400A frame. 78.74” (2m) cable $388.00 Nema 12 flexible shaft handle for 630A or 800A frame. 59.06” (1.5m)cable $399.00 Nema 12 flexible shaft handle for 630A or 800A frame. 78.74” (2m) cable DC Converters Transformers and Filters Circuit Protection Tools Test Equipment *Terminal covers for line side and load side included with Flange Disconnects. 2/pk Enclosures Enclosure Climate Control Flex Handle Specifications Operating instructions Frame Size Mechanical Endurance (cycles) Ambient Temperature Relative Humidity Protection Conforming Standards Environment • Operating handle facing up, Breaker is in ON position. • Operating handle facing down, Breaker is in OFF position or is reset. • Panel door cannot be opened when in ON, OFF or Trip position. In order to open the door, the handle must be turned toward reset position. • Release screw is standard. If you want to open a panel door in ON position, please turn the release screw using flat head screwdriver. 125A frame 250A frame 400A frame 10,000 8,000 6,000 630A/800 frame 6,000 14 to 140F (- 10 to 40°C) less than 95% RH NEMA Type12 IP54 (IEC60529) NFPA 79(2007), ANSI(Lockout), OSHA(1910.147, Lockout/tagout), UL489(cUL) No excessive dust, smoke, corrosive gases, flammable gases, steam or salt. Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-27 Safety: Electrical Components Safety: Protective Wear Terms and Conditions Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Field-mountable Accessories Dimensions Units: mm [inches] BW9F0CA BW9F0GA Book 3 (14.3) eCP-28 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Accessories Auxiliary Contacts The auxiliary contacts are accessory contacts for the indication of circuit breaker openclosed or tripped. Auxiliary Contacts for Fuji MCCBs – Selection Guide Breaker Type BW125 BW250 BW400 BW630 BW800 BW9W1SHA shown Part Number Price Description BW9W1SG0 $24.00 Auxiliary switch for for 125A and 250A frame. Mounting left and right side BW9W1SHA $22.50 Auxiliary switch for for 400A , 630A and 800A frame. Mounting left side ONLY Ratings of Auxiliary Switches Standard Type Rated Thermal Current (A) Breaker Type BW125, BW250, BW400 BW630, BW800 Make/Break Current (A) Voltage (V) AC Res. Load Ind. Load 24 5 5 48 5 125 250 5 Minimum Load Current Voltage (V) DC Res. Load Ind. Load 24 4 3 5 48 2.5 1 5V DC 160 mA 5 3 125 0.4 0.4 30V DC 30 mA 3 2 250 0.2 0.2 Operation of auxiliary switches Accessory Handle position ON Auxiiary switch OFF 11/AXcL Trip 14/AXaL 11/AXcL 14/AXaL SPDT (1) 12/AXbL 12/AXbL Shunt Trips Shunt Trip is for remote tripping (opening) of crircuit breaker. Shunt Trips for Fuji MCCBs – Selection Guide Part Number BW9FRG0 shown Price Description BW9FRG0 $49.50 Field installable 24 VAC/VDC shunt trip for BW125 and BW250 series MCCB. Left and right side mounting. Lead wires 20AWG, 19.69” long. BW9FHA-R $49.50 Field installable 24/48 VAC/VDC shunt trip for BW400, BW630 and BW800 series MCCB. Left side mounting only. Lead wires 20AWG, 19.69” long. BW9FAG0 $49.50 Field installable 100/120 VAC, 100-110 VDC shunt trip for BW125 and BW250 series MCCB. Left and right side mounting. Lead wires 20AWG, 19.69” long. BW9FHA-A $49.50 Field installable 100/240 VAC, 100-220 VDC shunt trip for BW400, BW630 and BW800 series MCCB.Left side mounting only. Lead wires 20AWG, 19.69” long. Ratings of Shunt Trips Breaker Type BW125, BW250 BW400, BW630, BW800 AC Voltage (V) DC Voltage (V) VA Time Rating of Coil W 24 50 24 50 100-120 50 100-110 50 24-48 2 24-48 2 100-240 3 100-220 3 Operating Time (ms) Continuous (with 1 N.O. contact to prevent coil burnout) 13-21 Continuous 8-20 Note: Allowable operating voltage AC voltage: 85% to 110% of coil rated voltage DC voltage: 75% to 125% of coil rated voltage Book 3 (14.3) eCP-30 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Accessories Company Information Terminal Blocks Power Distribution Blocks Undervoltage Releases Wiring Accessories Undervoltage Release will trip the circuit breaker when the connected voltage drops to less than 70% of undervoltage release voltage rating. It will allow the circuit breaker to close (ON) when voltage is approximately 85% of rated voltage. ZIPLink Connection System Multi-wire Connectors Undervoltage Releases for Fuji MCCBs – Selection Guide Breaker Type BW125, BW250 BW125, BW250 BW400, BW630, BW800 BW400, BW630, BW800 Part Number BW9RGAR BW9RGAT BW9RHA-R BW9RHA-1 Sensor Cables and Connectors Price Description $49.50 Undervoltage Release 24V DC (Left side ONLY) $49.50 Undervoltage Release 110 to 130 VAC VAC/VDC (Left side ONLY) $47.50 Undervoltage Release 24 VAC/VDC (Left side ONLY) $49.50 Undervoltage Release 120 to 130 VAC 125 VDC (Left side ONLY) M12 Junction Blocks Panel Interface Connectors Ratings of Undervoltage Trip Breaker Type BW125*1 BW250*1 BW400*2 BW630*2 BW800*2 AC Voltage (V) DC Voltage (V) VA Wiring Duct W – – 24 5 110 - 130 5 – – 24 2 24 2 120 - 130 3 125 3 BW9RGAR shown Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Note: Allowable operating voltage: A C voltage: 85% to 110% of coil rated voltage DC voltage: 75% to 125% of coil rated voltage. Power Supplies *1 Reset-allowed type: When the breaker handle is in the OFF or RESET state, tripping does not occur, even if the undervoltage trip coil is not energized. Turning ON with the undervoltage trip coil not energized causes normal tripping. *2 Reset-prohibited type: When the undervoltage trip coil is not energized, reset operation cannot reset the tripped breaker to the OFF state. DC Converters Transformers and Filters Circuit Protection Tools Replacement Lugs Test Equipment Enclosures Enclosure Climate Control Replacement Lug Kits for Fuji MCCBs – Selection Guide Part Number BW9SL0GA-3 shown Price Description Safety: Electrical Components BW9SL0CA-3 $50.50 Replacement lug kit for BW125 series MCCB. 75°C. Cu only Package of 3 BW9SL0GA-3 $57.00 Replacement lug kit for BW250 series up to 175A MCCB. 75°C. Cu only Package of 3 Safety: Protective Wear BW9SL1GA-3 $62.50 Replacement lug kit for BW250 MCCB series 200A to 250A. 75°C. Cu only Package of 3 Terms and Conditions Note: Terminals are factory-installed only for BW400, BW630 and BW800 series. No replacement terminals available. Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-31 Prices as of April 27, 2016. Check Web site for most current prices. Fuji Molded Case Circuit Breakers – Accessories Terminal Covers Terminal covers act as guards to shield the operator from touching live terminations. They fit either the line or load side. BW9BTHA-L3W shown Terminal Covers for Fuji MCCBs – Selection Guide Breaker Type Dimensions inch (mm) Part Number Price Description BW400 BW9BTHA-L3W Long type terminal cover for Fuji $49.00 Gray-white MCCBs. For line side and load side. 2/pk 6.772 (172) 4.331 (110) 3.858 (98) BW630, BW800 BW9BTJA-L3W Long type terminal cover for Fuji $52.00 Gray-white MCCBs. For line side and load side. 2/pk 8.268 (210) 6.102 (155) 3.858 (98) A B C Note: Gray-white short type terminal covers are provided with breakers as standard for 125 and 250 Amp frames. Dimensions of Terminal Covers: inch (mm) C B A Breaker Lockout Attachment Lockout Attachments for Fuji MCCBs – Selection Guide Breaker Type Part Number Price Description BW125 BW250 BW9Q1CA $12.00 Use to lock out BW125 and BW 250 series MCCBs. Lock not included BW400, BW630, BW800 BW9QNHA $29.00 Use to lock out BW400, BW600 and BW800 MCCBs. Lock not included. BW9Q1CA shown Book 3 (14.3) eCP-32 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5