2-679-0703 Electric Latch Retraction Sequencer Installation Instructions I-EA00140 ELECTRICAL SPECIFICATIONS Electric Latch Retraction Sequencer Input Voltage: 12VDC or 24VDC (+/- 10%) Input Current: 140mA max Exit & Operator Contacts: N/C or N/O, field selectable 10 AMP @ 30VDC (Resistive) Access Control Inputs: N/O Dry Contact T1 T2 1 J1 J2 J3 2 J4 1 2 3 4 ELR RELAY Adjust to control the length of time that the BAR ACTIVATION output relay activates. PERIOD DIP SW1 – Select Single or Tandem Door activation. SWITCHES SW2 – Select time period to delay operator activation STATUS LED’S - + POWER 1 2 3 4 BAR 1 OPR 1 5 6 7 8 BAR 2 OPR 2 Channel 1 Channel 2 C NO C NO AC 1 AC 2 Provides a visual indication of the device latch status and relock timer status ACCESS A momentary closure will activate the ELR device. CONTROL The device will release after the input is removed and INPUTS the relock activation period has expired. DOOR OPERATOR Isolated relay contacts provide a delayed signal OUTPUTS (OPR) to activate the automatic door operator. EXIT DEVICE Goes inline with the locking device power or OUTPUTS (BAR) connects to the power booster for Hager ELR exit devices. SEQUENCER OPERATION: The electric latch retraction sequencer module may be used with any Hager latch retraction system such as the Hager 4501 ELR or the 4501 MLR, any Hager electric strike, or any Hager maglock to provide a delayed signal to operate an automatic door operator or when powering a pair of exit devices from a Hager 2909 power supply. The two sequencer channels may be operated as two independent doors or in tandem mode for pairs of doors. Each sequencer channel provides dry output for powering the exit device and a “delayed” dry auxiliary output for activation of an automatic door operator. All outputs are field selectable as Normally Open or Normally Closed. When the Electric Latch Retraction Sequencer is used in the tandem mode, power supply requirements for a pair of doors are minimized. Since the attached electric latch retraction devices are powered in a sequential manner, the inrush current of each device is staggered. This creates a lower current requirement upon activation. A smaller power supply can now be used to operate the pair of devices . Rev -, Rev Date: 01/09/15 Always visit www.hagerco.com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Page 1 of 3 2-679-0703 Electric Latch Retraction Sequencer Installation Instructions I-EA00140 ELECTRIC LATCH RETRACTION SEQUENCER MLR TYPICAL WIRING AC VOLTAGE INPUT S E C UR I T Y D OOR C ONT R OL S RELAY CONFIGURATION JUMPERS Jumper Relay Terminals J1 BAR 1 1&2 J2 OPR 1 3&4 J3 BAR 2 5&6 J4 OPR 2 7&8 Hager 2909 T2 CHG 1 24V + - J1 J2 2 J3 J4 12V 1 2 3 4 1 2 3 4 SINGLE 3 SEC } Not Used C - + POWER 1 2 BAR 1 3 4 OPR 1 5 6 BAR 2 7 8 OPR 2 C NO C NO AC 1 AC 2 * TANDEM 6 SEC N/O FLOAT VOLTAGE SELECT SWITCHES N/C ADJUSTABLE RELOCK TIMER T1 = BAR 1; T2 = BAR 2 (10 to 35 seconds; Added to Access Control Input time) T1 + C N/O N/C Access Control Input #2 Access Control N/C Input C #1 N/O Tandem Mode, use only *InAccess Control Input #1 Operator Power MLR DEVICE #1 DOOR OPERATOR #2 Operator Power Power Transfer DOOR OPERATOR #1 MLR DEVICE #2 Power Transfer Power Supply Power Supply 2909 x 2-679-0703 2909 x 2-679-0703 Automatic Operator Automatic Operators Access Control Access Control Power Transfer Hinge 4501/4601 MLR SINGLE DOOR Rev -, Rev Date: 01/09/15 Power Transfer Hinge 4501/4601 MLR 4501/4601 MLR Power Transfer Hinge PAIR OF DOORS (TANDEM) Always visit www.hagerco.com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Page 2 of 3 2-679-0703 Electric Latch Retraction Sequencer Installation Instructions I-EA00140 ELECTRIC LATCH RETRACTION SEQUENCER ELR TYPICAL WIRING AC VOLTAGE INPUT S E C UR I T Y D OOR C ONT R OL S RELAY CONFIGURATION JUMPERS Jumper Relay Terminals J1 BAR 1 1&2 J2 OPR 1 3&4 J3 BAR 2 5&6 J4 OPR 2 7&8 Hager 2909 T2 CHG 1 24V + - J1 J2 2 J3 J4 1 2 3 4 12V 1 2 3 4 SINGLE 3 SEC N/O C - + POWER 1 2 BAR 1 3 4 OPR 1 5 6 BAR 2 7 8 OPR 2 * TANDEM 6 SEC } Not Used FLOAT VOLTAGE SELECT SWITCHES N/C ADJUSTABLE RELOCK TIMER T1 = BAR 1; T2 = BAR 2 (10 to 35 seconds; Added to Access Control Input time) T1 + C N/O C NO C NO AC 1 AC 2 N/C Access Control Input #2 Access Control N/C Input C #1 N/O Tandem Mode, use only *InAccess Control Input #1 Operator Power Operator Power DOOR OPERATOR #1 DOOR OPERATOR #2 Power Booster 1 2 RELAY Power Booster + 6 - 5 + 4 - 3 1 2 + 2 1 RELAY ELR DEVICE #1 Power Transfer Rev -, Rev Date: 01/09/15 Power Transfer Always visit www.hagerco.com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 + 6 - 5 + 4 - 3 + 2 1 ELR DEVICE #2 Page 3 of 3