SOLAR PCU – SUN MAGIC (3KVA to 6KVA) FEATURES True bidirectional inverter/solar PCU Hybrid inverter (Solar /Grid/ BATT) Single phase i/p, single phase o/p Range 1KVA to 15KVA MPPT Based Solar Charger Generator compatible Modes available are SGB/GSB/SBG/GFM /INV(selectable) SBG Modes with Buffer level selection facility 25/50/75 Grid FEED Function/Mode (GFM) Available GFM Feeds power to grid when grid available, feeds power to load When grid fails. GFM levels are selectable 0/25/50/75/100 Changeover time less than =20ms Input power Factor for grid charging – near to unity Zero loss on bypass mode/ grid mode Auto bypass and manual bypass Optional RS232 Solar KW and KWH Meter Fault logs Optional I/P Terminal Wind Auto fault reset for non critical faults Multi mode MPPT charger SUN MAGIC (3KVA TO 6KVA) INVERTER Continuous Rated Output Power DC Voltage Output Voltage (Inverter Mode) Output Frequency (Free Running) Output Waveform Peak Inverter Efficiency (Full Load) Overload Changeover Time (At Full Load) Bypass Facility DC To AC Isolation 3KVA 5KVA 6KVA 2400 W 96 V 4000 W 96 V 230V AC ±2%, 1 Phase 50Hz ± 0.5% Pure Sine Wave >90% 125% FOR 60 SEC, 150% FOR 5 SEC <=20ms Manual for Service Transformer 4800W 96 V BATTERY Nominal Battery Voltage Grid Charging Current 96V DC Selectable Input Power Factor (Grid Charging) Near to Unity Battery Charging Voltage Selectable INPUT Input Voltage Range 170V to 260V (±5V), 1 Phase DG Compatibility Input Frequency Range Yes 50Hz ± 6% SOLAR Charger Type MPPT Max PV Voltage (VOC) 180V Min PV Voltage (VMPP) MPPT Modes Available 115V 2 ( Selectable) Solar Charger Current Rating KVA=KW as per rating Panel Reverse Protection YES Solar Charger Efficiency >92% CONFIGURATION Modes Available SBG/SGB/GSB/Grid Feed mode/Inv Battery Buffer Setting SELECTABLE GRID Feed Mode RESET SELECTABLE Manual Fault Reset/Buzzer Reset YES Auto Reset BATTERY Low and Overload DISPLAY Input Output Battery Voltage, Current and Frequency Voltage, Current and Frequency Voltage and %of Discharge Solar Other Voltage, Current, KW, KWh Current Status, Configuration, Fault Log INDICATIONS LCD Grid On, PV On, Grid Charger On, Inverter On, Load On Mains, Load On Grid, Fault KVA Rating, Current Status, Input -Voltage/Current/Frequency, Inverter –Voltage/Current, Output- Voltage/Current/Frequency, Solar-Panel Voltage /Current &KWH Rating, Battery-Voltage &Status ,Configuration ALARM Audible For Fault And Warnings LED ENCLOSURE Degree of Protection Indoor Cooling Force Air Cool Siemens Grey Color ENVIRONMENTAL Temperature Range (Operating) Temperature Range (Storage) Altitude (max) 0°C to 40°C -10°C to 60°C 1000m Battery Reverse Indication Panel Reverse Indication OPTIONAL @ Extra PV Side Surge Protection RS 232 Communication Port GSM Remote Monitoring Facility Wind Charger Connection Terminal Wind charge current Solar radiation (with external Pyranometer) Wind speed (with external anemometer) Disclaimer : 1. Specification Subjected to Change without Prior Notice 2. Stabilizer not recommended for GRID FEED Mode 3. Additional External Protection Recommended for Battery and Output Side 4. Display Parameters are for Indicative Purpose Only. Subjected to Accuracy 5. Load shall be cross verified before connecting 6. System Not Designed for any Life support system ENERTECH UPS PVT LTD S. No. 399/1-2, Bhare, P.O. Ghotawade, Near MSEB Substation, Pirangut, Taluka -Mulshi, Pune – 412115 T: 020-22923172, F: 020-20291176 Email – sales@enertechups.com Website: www.enertechups.com West: Mumbai | Nagpur | Aurangabad | Kolhapur | Ahmedabad | Surat | Jaipur | Indore| Bhopal South: Bangalore| Hyderabad | Vizag | Chennai | Madurai | Coimbatore | North: Delhi | Jammu | Gurgaon | Noida